Sunteți pe pagina 1din 1

No.

: 2005-Draf

No. 2
Previous No.: 2005-2
Date: June 2005

Subject: Hydraulic Operated Center Latch Elevators for 350 ton

Purpose: To inform the industry on the correct use of Hydraulic


Operated Center Latch Elevator

Effective: B+V VES-CL 350-H, P/N 613900-Y-H, 350 ton

Description of incidents:

Blohm + Voss was informed of an incident with the VES-CL 350-H Elevator.

The Link Block Assembly for the Hydraulic Cylinder was not correct installed (see Picture 1).

Damaging of Latch Lock Pin, Actuator and Link Block Screws are the result of wrong installation.

Picture 1: Link Block Assy. for Cylinder wrong installed Picture 2: Link Block Assy. for Cylinder correct installed

Recommendation to the industry:

Check Elevator for correct installation of Link Block Assy, if this is not correct insatalled, please contact
Blohm+Voss Repair GmbH.

Page 1 of 1
Production and Service Stocking and Service Stocking and Service Stocking and Service
Head Office Houston, Texas/USA Singapore/Republic Aberdeen/
Hamburg/Germany of Singapore United Kingdom

Blohm + Voss Repair GmbH Gray EOT, Inc. Premier Sea & Land Pte. Ltd. Stacey Oil Services Ltd.
Hermann-Blohm-Straße 2 P.O. Box 79485 1, Scotts Road #19-12 Unit AJ, Badentoy Crescent
20457 Hamburg, Germany Houston, Texas Shaw Centre Portlethen, Aberdeen AB12 4YD
Phone: +49-40-31 19-81 42 77279-9485 Singapore 228208 United Kingdom
+49-40-31 19-81 27 United States of America Republic of Singapore Phone: +44-12 24-78 18 87
Fax: +49-40-31 19-34 00 Phone: +1-713-95 20 266 Phone: +65-734-71 77 Fax: +44-12 24-78 21 62
+49-40-31 19-81 94 Fax: +1-713-95 22 807 Fax: +65-734-91 15
E-mail: E-mail: E-mail:
info@blohmvoss-oiltools.com E-mail: Grayeot@wt.net ironside@premier-ips.com.sg mail@staceyoil.com

S-ar putea să vă placă și