Sunteți pe pagina 1din 436

37779-7-8811 • KO-08/07-10,8’

Printed in Germany
version 07
Axial fans

version 07
Axial fans
ebm-papst ebm-papst ebm-papst
Mulfingen GmbH & Co. KG St.Georgen GmbH & Co. KG Landshut GmbH

Bachmühle 2 Hermann-Papst-Straße 1 Hofmark-Aich-Straße 25


D-74673 Mulfingen D-78112 St.Georgen D-84030 Landshut
Phone +49 (0) 7938 / 81-0 Phone +49 (0) 7724 / 81-0 Phone +49 (0) 871/ 707-0
Fax +49 (0) 7938 / 81-110 Fax +49 (0) 7724 / 81-1309 Fax +49 (0) 871 / 707-465
info1@de.ebmpapst.com info2@de.ebmpapst.com info3@de.ebmpapst.com

www.ebmpapst.com

The engineer’s choice


information
General
General information 4

Axial fans – Company profile: ebm-papst


– Our key to success
– How to use this catalogue

AC axial fans
– How to find your ebm-papst product
– How to order your ebm-papst product

AC axial fans, AC diagonal fans 13


ebm-papst's axial fans prove their reputation as space-saving wonders by moving air for hot or cold
air exchange in a wide variety of devices and systems. Their outstanding features are their small

AC axial
AC axial fans, S series 23

S series
installation depth, low noise level and exceptional efficiency, and are particularly well suited for air
flow through heat exchangers. AC axial fans, K series 131
Furthermore, in the EC version, they become intelligent "energy-saving wonders" for an extremely
wide range of applications, primarily in ventilation, air-conditioning and refrigeration technology and
AC axial fans, A series 157

AC axial
K series
the automotive industry. Table of content

EC axial fans, EC diagonal fans 179

One principle, countless options


The axial fan, the function of which is similar to EC axial fans, S series 185

AC axial
A series
a propeller, moves the air axially, parallel to the
revolving motor shaft. The ebm-papst external Square shaded-pole motors (Q-motor) 301
rotor motor is integrated directly into the axial
impeller, forming a compact axial fan unit. They

EC axial fans
Energy-saving motors (ESM) 315
are usually installed with wall rings in short or
long nozzles.
EC-SYSTEMS 329
The extensive ebm-papst product range offers
– Options
the right solution for each requirement and is
– Switch power supplies
classified for a wide variety of applications:

EC axial
S series
– External commutation electronics for rail technology
– S series with sickle-shaped blades for high
– Temperature sensor / control module
air flow at medium pressure
– Pressure control / selection module for 3 speeds
– K series with especially low noise level –
– Interface converter / RS485 repeater
ideally suited for refrigeration plant
– RS485 terminal box / hand-held control terminal
applications

Q-motor
– Speed setting
– A series for high-pressure applications
– LISA control software / fan control software
– HMS controller

Accessories 361

ESM
– Guard grilles, streamers
– Wall rings
– Connection leads
– Accessories for Q-motors and ESM

EC-SYSTEMS
– Terminal boxes, capacitors
– Speed setting
Design according to requirements
– Motor protection switch
Energy efficiency, controllability and low-noise precision open and closed-loop control with
– Star-delta switch / repair switch
performance – and all this together with very high efficiency. The following standard

Accessories
external rotor motors in AC and EC technology: features are available: Technology 391
ebm-papst axial fans are optimally matched to tach output, error message, linear or PWM – Technical parameters & scope
customer requirements. input, temperature or flow rate-dependent – Impellers
The EC technology (12 VDC to 110 VDC or control systems or bus-connectable interface. – Motors
line-voltage-powered 100 VAC to 480 VAC) with

Technology
– Control technology
integrated or external electronics enables
Distributors, agencies and subsidiaries 430

is a registered trademark of ebm-papst Mulfingen GmbH & Co. KG

Contacts
2 3
information
General
General information 4

Axial fans – Company profile: ebm-papst


– Our key to success
– How to use this catalogue

AC axial fans
– How to find your ebm-papst product
– How to order your ebm-papst product

AC axial fans, AC diagonal fans 13


ebm-papst's axial fans prove their reputation as space-saving wonders by moving air for hot or cold
air exchange in a wide variety of devices and systems. Their outstanding features are their small

AC axial
AC axial fans, S series 23

S series
installation depth, low noise level and exceptional efficiency, and are particularly well suited for air
flow through heat exchangers. AC axial fans, K series 131
Furthermore, in the EC version, they become intelligent "energy-saving wonders" for an extremely
wide range of applications, primarily in ventilation, air-conditioning and refrigeration technology and
AC axial fans, A series 157

AC axial
K series
the automotive industry. Table of content

EC axial fans, EC diagonal fans 179

One principle, countless options


The axial fan, the function of which is similar to EC axial fans, S series 185

AC axial
A series
a propeller, moves the air axially, parallel to the
revolving motor shaft. The ebm-papst external Square shaded-pole motors (Q-motor) 301
rotor motor is integrated directly into the axial
impeller, forming a compact axial fan unit. They

EC axial fans
Energy-saving motors (ESM) 315
are usually installed with wall rings in short or
long nozzles.
EC-SYSTEMS 329
The extensive ebm-papst product range offers
– Options
the right solution for each requirement and is
– Switch power supplies
classified for a wide variety of applications:

EC axial
S series
– External commutation electronics for rail technology
– S series with sickle-shaped blades for high
– Temperature sensor / control module
air flow at medium pressure
– Pressure control / selection module for 3 speeds
– K series with especially low noise level –
– Interface converter / RS485 repeater
ideally suited for refrigeration plant
– RS485 terminal box / hand-held control terminal
applications

Q-motor
– Speed setting
– A series for high-pressure applications
– LISA control software / fan control software
– HMS controller

Accessories 361

ESM
– Guard grilles, streamers
– Wall rings
– Connection leads
– Accessories for Q-motors and ESM

EC-SYSTEMS
– Terminal boxes, capacitors
– Speed setting
Design according to requirements
– Motor protection switch
Energy efficiency, controllability and low-noise precision open and closed-loop control with
– Star-delta switch / repair switch
performance – and all this together with very high efficiency. The following standard

Accessories
external rotor motors in AC and EC technology: features are available: Technology 391
ebm-papst axial fans are optimally matched to tach output, error message, linear or PWM – Technical parameters & scope
customer requirements. input, temperature or flow rate-dependent – Impellers
The EC technology (12 VDC to 110 VDC or control systems or bus-connectable interface. – Motors
line-voltage-powered 100 VAC to 480 VAC) with

Technology
– Control technology
integrated or external electronics enables
Distributors, agencies and subsidiaries 430

is a registered trademark of ebm-papst Mulfingen GmbH & Co. KG

Contacts
2 3
Company profile: ebm-papst

The entire scope of ventilation and drive technology: this is the world of ebm-papst. More than 9,800 people – in
Germany and throughout the world – develop, produce and sell our motors and fans. Our global presence and
our unique range of products based on a quality standard that surpasses every other have made us what we are:
world market leader in motors and fans. Expertly knowing what our customers need and incessantly striving
to arrive at the perfect application solution for a wide variety of different industries is what determines our daily
work. Those who know us know the high standards we apply to our work and know our creed: to be as close
to our customers as possible and to simply be the best in terms of innovation and reliability.

Our headquarters in Mulfingen

4
information
General
AC axial fans
AC axial
S series
Left:
Our location in St. Georgen
Right:

AC axial
K series
Our location in Landshut

Our history – Our drive clearance for serial production only after all the
Rooted in ebm, PAPST and mvl, the three leading innovators in the desired characteristics have been determined to

AC axial
A series
development and production of motors and fans, ebm-papst has be just right.
established itself as the world market leader. Now as ever, our legendary Environmental care is another priority with
inventive spirit shines through in products that set standards in many ebm-papst. This is why we have developed
segments of industry worldwide. We are proud to say that despite difficult our product line in EC technology, which makes

EC axial fans
competition, our performance has always been exemplary and outstand- for very low power consumption. Due to our
ing – in business, in our personal relationship with our customers, and of manufacturing philosophy, there is absolute
course with respect to technology and engineering. For decades, we have focus on environmental care in production,
contributed to the world of air technology and drive engineering with recycling, waste and waste water disposal.
small revolutions and large milestones.

EC axial
S series
To maintain this advantage in skills and knowledge to get maximum Global Domestic
quality and thus the highest degree of customer satisfaction, our In order to be specialist for customised solutions
employees around the world put their passion and dedication to work throughout the world, you need strong partners.
for you. Global Domestic – i.e. being present all over the
world and being a national company in each

Q-motor
Passionately involved in R&D individual country – is how we have established
Our catalogues just list the results of our incessant efforts in R&D: ourselves in all important markets on this globe
products of highest quality and reliability. After all, it is our passion to with our successful subsidiaries. And so you will
constantly try something new and improve what we have. In doing so, always find ebm-papst close to home, speaking
we take advantage of the latest development methods and state-of- your language, and knowing the demands of

ESM
the-art technology and invest quite heavily in R&D facilities. Best of all, your markets. Besides, our worldwide produc-
though, we rely on excellently trained and skilled engineers and tion alliance serves as a basis for competitive
technicians to be at your service in R&D and Sales & Distribution. pricing. Our global services and logistic outlets,
EC-SYSTEMS

i.e. IT networking, safeguard short reaction


Producing and safeguarding high-quality products and services times and just-in-time delivery.
This is our promise without any compromise. Whether produced in one of
our five factories in Germany or one of our eleven international production All our efforts are documented in a comprehen-
sites, our products always have the same high level of quality. This quality sive quality management system, both for prod-
Accessories

control is something you can definitely rely on! And this across all levels ucts and services. Being certified as complying
of production and throughout all processes: consulting customers, devel- with the tough requirements of the international
opment, material selection through to picking certified, choice suppliers standards DIN EN ISO 9001, ISO/TS 16949-2
and on to the production of parts and final delivery. On top of this, our and of standard DIN EN ISO 14001 is just one
products have to pass the most rigourous tests under all realistic operat- seal of approval we have received for our
Technology

ing conditions: continuous stress test, salt spray test, vibration test, or unceasing efforts to provide only the best
precision noise measuring, just to mention a few. And the product gets quality products and services.
Contacts

5
Our key to success

Our innovations and technologies keep on turning into new industrial standards. This competitive capability can
only be maintained by seeing ventilation as a whole: the interrelationship between, and thus the system of, motor
engineering, aerodynamics, and electronics. These are our three core competencies, imminently connected and
linked in each of our products. And so we handle air intelligently and quietly and continue to set new standards in
drive technology. Our system solutions form the main part of our product range by now. And they will be our main
key to success.

Production Winding machine

Motor engineering, aerodynamics, electronics Finally, intelligence will become the decisive
Our drive is well known and famous with specialists: our external-rotor factor on all markets in future. After all, only in
motor, which has made us world market leader – quietly, yet powerfully. connection with electronics can drive and air
Being versatile as to integration, it is ideally suited to the most diverse flow – as a system solution – have an optimal
applications. Based on this principle, we here at ebm-papst have devel- effect in a product or application. Interfaces are
oped the widest range of fans and motor types in the world. And for hot avoided, and thus potential faults and failures.
or aggressive blower mediums, the internal-rotor motor is the perfect
complement. Setting new standards with EC technology
Wherever intelligent air handling is required,
Still, in drive engineering, certain applications simply require the internal- where energy consumption needs to be reduced
rotor motor principle, and they are then realised with our motors specifi- and performance has to be maximised, there
cally developed for such cases. Take, for instance, the steering support our EC motors are your reliable answer. They do
motor in the automotive field developed as innovation in active steering. not waste financial or natural resources.
Instead, they boost high efficiency, continuous
Be it axial or centrifugal fans, centrifugal blowers, compact fans or controllability via analogue or digital inputs,
tangential blowers: we always design fan blades, impeller blades and long and maintenance-free service life, and
ducted housings with the specific application in mind. We strive to robustness.
minimise noise and to optimise efficiency. This is the challenge that
we have taken up and which we meet – working away powerfully
and quietly.

6
information
General
AC axial fans
AC axial
S series
Left: Endurance test room
Centre: Shaker

AC axial
K series
Right: Measurement station

AC axial
A series
EC axial fans
Top: Betz manometer

EC axial
S series
Left: Precision noise measurement lab

– EC fan units for clean room technology.

Q-motor
As the electronics are integrated and the unit
is wired up completely and ready to plug in,
there is no need for our customers to waste
time and money on laborious wiring work.
– Sensitive EC sensor fans for the automotive

ESM
Without any problems, the ebm-papst EC technology allows you to realise industry providing optimal selection of the
networked, bus-linked appliances, to integrate simple or complex controls air-conditioning unit in the car and, combined
at low cost and to also realise time and again new, customised and with booster blowers, individual air-condition-
EC-SYSTEMS

complete solutions. Here, ebm-papst excels as competent development ing of each and every passenger seat.
partner, with our experience of more than 25 years and our excellent – EC gas blowers with commutation and
know-how in R & D and production also being well documented in a few control electronics including a processor.
hundred national and international patents. And there is also our ability They are developed in such a way as to
to listen intently, to pay good attention to our customers and their make the blower premix the required amount
Accessories

demands – in order to come up with new and pioneering ideas, such as: of air with the gas. Aerodynamics with these
blowers are adjusted in such a way as to
make these blowers ideal for use in very
limited space at high back pressure.
Technology
Contacts

7
How to use this catalogue

The ebm-papst catalogue combines a technical and a product-specific section.


Technical section: General information on how to select and find ebm-papst products for your specific
application is found in the chapters "Selection" (p. 10) and "Technical parameters" (p. 392).
In case you require technical background information on ebm-papst product groups, simply turn to
the chapters "Impellers" (p. 396), "Motors" (p.410) and "Control technology" (p. 414).
Product-specific section: The product-specific section is organised according to product diameters,
lines, materials and/or design principles.

Headline
The headline indicates which technology (AC or EC), which design AC centrifugal fans
(centrifugal, axial, etc.), and which line (e.g. S-Range) the product belongs backward curved, 3-D, Ø 400

to. Impeller diameter or other features are also indicated. – Material: Impeller: Sheet aluminium, joined by tabs
Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
Part designation / Type – Bearings: Maintenance-free ball bearings

R 2 E 190 -AO 26 -05 This key designates and identifies all


ebm-papst products and serves as

Perm. amb. temp.

Electr. connection
Nominal voltage
123 4 5 6 7

Speed/rpm (1)
part number:

Max. current
Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

1) Type Nominal data


Type Motor VAC Hz rpm W A µF/VDB °C p. 596 f.
A - axial fan R4E 400 M4E 094-FA
F A
1~ 230 50 1355 375 1.75 8.0 /400 -40 to +60
A2a)
1~ 230 60 1480 540 2.40 8.0 /400 -40 to +50
S - axial fan with guard grille R4E 400 M4E 094-HA B
1~
1~
230
230
50
60
1370
1460
480
700
2.40
3.15
10.0 /450
10.0 /450
-40 to +80
-40 to +55 A2a)
subject to alterations (1) Nominal data in operating point with maximum load

W - axial fan with wall ring


V - axial combination
R - centrifugal fan, single inlet
G - centrifugal blower, single inlet (with scroll housing)
n P1 I LpA
B - centrifugal fan, dual inlet Curves [rpm] [W] [A] [dB(A)]

D - centrifugal blower, dual inlet (with scroll housing) A 1 1350 370 1.75 64
[Pa]

[in H O]
2

A 2 1380 331 1.58 65


B 1 1370 469 2.37 66
K - centrifugal combination
2,5

600
B 2 1390 430 2.17 68

M - motor
2,0

500

P - pumps 400 2 2
1,5

2) Number of poles (AC) / number of cores (EC)


300

2-, 4-, 6-, 8- and 12-pole (Z = 12) / 1- and 3-core


1,0

200 1 1

3) Motor type B
0,5

A
100

D - 3-phase motor
E - single-phase motor with operating capacitor
0 500 1000 1500 2000 2500 [CFM]

1000 2000 3000 4000 [m3/h]

50 Hz 60 Hz

G - EC motor
56
S - shaded-pole motor
Q - square shaded-pole motors
4) Impeller diameter in mm What a product page is made up of (reduced scale - 50%)

5) Key for mechanical design


6) Key for electrical design
7) Key for mechanical variants

8
information
General
AC axial fans
AC axial
S series
AC axial
K series
Product description

information
Depending on the product, information is provided here on the following:
General

AC axial
A series
material, number of blades, direction of air flow, direction of rotation,
– Motor protection: Design with thermal overload protector
system of protection, insulation class, mounting position, condensate
AC centrifugal,

– Cable exit: Diagonal


backward

– Protection class: I (acc. to EN 61800-5-1) discharge holes, mode of operation, design, bearing, technical equipment,
– Product conforming to standard: CE
EMC, leakage current, motor protection, electrical connection, cable exit,

EC axial fans
protection class, capacitor, product conforming to standards, approvals
AC centrifugal,

and options.
forward
EC centrifugal,
centrifugal fan

backward

Nominal data
Mass of

Dimensions AC products (up to motor size 074) and EC products (DC-fed):

EC axial
S series
Inlet nozzle
Centrifugal fan kg b c d e g (long)
Free-blowing or at minimal backpressure
ward for clean rooms
EC centrifugal, back-

R4E 400-AR05 -06 7.1 141.0 172.0 128.0 50.0 90.0 54476-2-4013

R4E 400-AP17 -06 8.8 164.0 193.0 148.0 70.0 113.0 54476-2-4013 AC products (from motor size 094) and EC products (AC-fed):
In operating point at maximum load
c ±1 66
EC centrifugal,

Q-motor
forward

5 d ±1 22
50

11
90

Graphic rendition of products


±0
,3
Ø 100 -0,4

EC-SYSTEMS

e
Ø 257
Ø 124

Ø404

Ø 370
Ø268

All drawings represent the design principle and are not to scale.
M6
Dimensions are either given in the product drawing or, with varying
0

45˚
60

ESM
dimensions, in the table of dimensions given above the drawing.
2
Accessories

g Depth of screw
Brass lead tips max. 12 mm
b
Mounting dimensions
Ø7
EC-SYSTEMS
Technology

Indication of relevant accessories and additional information


Ø
11
Ø

5
10
0

The pages indicated at the bottom refer to the accessories, e.g. inlet
55

28
nozzles, guard grilles, wall rings, etc. for this particular product,
as well as additional information (e. g. the connection diagram).
Contacts

57
Accessories

Inlet nozzle Guard grille Capacitor Electr. connections


p. 550 p. 553 p. 560 f. p. 596 f.

Curves and operating points


The diagram gives air performance curves pertaining to the product.
Technology

Refer to the operating point table to the right for information on speed,
power consumption, current draw, sound level or sound pressure level
and overall efficiency of the impeller.
Contacts

9
How to select your ebm-papst product

Solutions for ventilation offered by ebm-papst


In the field of ventilation, ebm-papst offers the perfect solution for a vast number of applications. Depending on motor,
impeller and control technology, there is almost no limit to the number of possible combinations, thus making sure you can
find the best solution for your application.

Criteria for selection


When selecting a fan for a specific application, these parameters play an
important role:
– Air flow with given back pressure
– Voltage supply, divided into DC and AC voltage (1~, 3~)
– Noise generation
– Efficiency
– Available mounting space

Selecting a fan
The following diagram shows the range of characteristic curves for the
most important fan designs and serves as a helpful tool in preselecting
a design on the basis of air flow and back pressure.

Characteristic curves of the various designs


[Pa]

axial fans
centrifugal fans, backward curved
1200 centrifugal blowers, single inlet
centrifugal blowers, dual inlet
1000 diagonal fans

800

600

400

200

200 500 1000 2000 5000 10000 20000 50000 [m³/h]

10
information
General
How to order your ebm-papst product

AC axial fans
AC axial
S series
Have you found the suitable ebm-papst product and would like to order it now?
In this case, simply contact your nearest ebm-papst sales office by E-mail, fax or phone.

AC axial
K series
Don't know exactly which ebm-papst product you need to order? Checklist
In this case, simply contact your nearest ebm-papst sales office by

AC axial
A series
E-mail, fax or phone. Our specialists in ventilation and drive technology – Part designation / type
are always there to help you find the best solution for your specific – Quantity needed
application. – Field of application
– Ambient conditions (humidity, temperature, climate)

EC axial fans
Using the questions provided in the checklist here as a guideline, you can – Impeller diameter
make sure your ebm-papst contact has all the necessary information to – Air flow
handle your enquiry as efficiently and quickly as possible. – Back pressure
– Voltage supply

EC axial
S series
How your ebm-papst product is delivered
In our order confirmation, you will find information on when, how and
where to the delivery will be made.

We deliver:

Q-motor
– Ex works (excluding packaging)
– Via freight carrier (we also use postal services for shipments
up to 30 kg)

All the other details such as packaging, freight, insurance and customs

ESM
duty will be settled with your ebm-papst contact prior to the time we
issue our order confirmation.
EC-SYSTEMS

For your nearest sales office, please turn to page 430.


Is there anything else you need to know about your
ebm-papst product?
In this case, simply contact your nearest ebm-papst sales office by
E-mail, fax or phone. We have the answer to your problem and are
Accessories

always glad to be able to be of assistance.

Using the questions provided in the checklist here as a guideline, you can
make sure your ebm-papst contact has all the necessary information to
handle your enquiry as efficiently and quickly as possible.
Technology
Contacts

11
12
AC axial fans

AC diagonal fans
AC axial fans, AC diagonal fans

Ø 208
Ø 130 - Ø 250

13
20
14

Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
Ø 130

– Material: – Condensate discharges: None


Wall ring: Die-cast aluminium, – Mode of operation:
coated in black Continuous operation (S1)
Blades: Sheet steel, coated in black – Bearings: Maintenance-free ball bearings
Rotor: Open, coated in black – Motor protection: TOP wired internally
– Number of blades: 7 – Electrical connection:
– Direction of air flow: "V", exhaust over Cable length 330 mm, beginning at wall ring
struts – Protection class: I
– Direction of rotation: Counter-clockwise, – Product conforming to standards:
seen on rotor EN 60335-1, CE
– Type of protection: IP 20 – Approvals: VDE, UL, CSA, CCC, GOST
– Insulation class: "B"
– Mounting position: Any

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Current draw
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Mass
Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

1~ 115 50 325 2800 41 — — 49 80 -25 to +60


W2S 130-AA25 -01 M2S 052-CA A
1~ 115 60 380 3250 38 — — 53 120 -25 to +80 1.1 B)
1~ 230 50 325 2800 45 — — 49 80 -25 to +50
W2S 130-AA03 -01 M2S 052-CA A
1~ 230 60 380 3250 39 — — 53 120 -25 to +70 1.1 B)
subject to alterations

Brass lead tips

150±0.5
55±0.3

Curves
Ø4,35/Ø4,45-0.05

[Pa]

[in H O]
72 0.3 1

2
Ø1 62- +0.

160
.5
±0
Ø1

6 5
0,6

"V" 
120
0,4

80

A
0,2

40

0 50 100 150 200 [CFM]

100 200 300 [m3/h]

50 Hz 60 Hz

14
Guard grille Electr. connections
p. 368 p. 416 f.
information
General
AC axial fans
Ø 130

AC axial fans
– Material: – Condensate discharges: None
Wall ring: Die-cast aluminium, – Mode of operation:
coated in black Continuous operation (S1)
Blades: Sheet steel, coated in black – Bearings: Maintenance-free ball bearings
Rotor: Open, coated in black – Motor protection: TOP wired internally

AC axial
S series
– Number of blades: 5 – Electrical connection:
– Direction of air flow: "A", intake over Cable length 330 mm, beginning at wall ring
struts – Protection class: I
– Direction of rotation: Counter-clockwise, – Product conforming to standards:
seen on rotor EN 60335-1, CE
– Type of protection: IP 20 – Approvals: VDE, UL, CSA, CCC, GOST

AC axial
K series
– Insulation class: "B"
– Mounting position: Any

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

AC axial
A series
Current draw
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Mass
Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

EC axial fans
1~ 115 50 380 2700 47 — — 60 — -25 to +50
W2S 130-BM15 -01 M2S 052-CA B
1~ 115 60 425 3050 46 — — 62 — -25 to +70 1.1 B)
1~ 230 50 380 2700 47 — — 60 — -25 to +50
W2S 130-BM03 -01 M2S 052-CA B
1~ 230 60 425 3050 46 — — 62 — -25 to +70 1.1 B)
subject to alterations

EC axial
S series
Brass lead tips

6 6
Ø4,45-0.05/Ø4,20+0.05

Q-motor
150±0.5

Curves
[Pa]

[in H O]
2

ESM
120
+0.15
162 -0.30 55±0.2
172±0.5
0,4

100
EC-SYSTEMS
 "A"

80
0,3

60
Accessories
0,2

40
0,1

20
Technology

0 50 100 150 200 250 [CFM]

100 200 300 400 [m3/h]

50 Hz 60 Hz
Contacts

15
Guard grille Electr. connections
p. 368 f. p. 416 f.
AC axial fans
Ø 142

– Material: – Condensate discharges: None


Wall ring: Die-cast aluminium, – Mode of operation:
coated in black Continuous operation (S1)
Blades: Sheet steel, coated in black – Bearings: Maintenance-free ball bearings
Rotor: Open, coated in black – Motor protection: TOP wired internally
– Number of blades: 7 – Electrical connection: Blade terminal
– Direction of air flow: "V", exhaust over 2.8 x 0.5 mm (operating capacitor
struts connected)
– Direction of rotation: Counter-clockwise, – Protection class: I
seen on rotor – Product conforming to standards:
– Type of protection: IP 22 EN 60335-1, CE
– Insulation class: "B" – Approvals: VDE, UL, CSA, CCC, GOST
– Mounting position: Any

Max. operative range


Sound pressure level

Perm. amb. temp.


Nominal voltage

Current draw
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Mass
Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg

1~ 115 50 330 2800 25 — — 52 — -25 to +55


W2E 142-BB05 -01 M2E 052-BA A
1~ 115 60 390 3300 24 — — 57 — -25 to +70 0.9
1~ 230 50 330 2800 25 — — 52 — -25 to +55
W2E 142-BB01 -01 M2E 052-BA A
1~ 230 60 390 3300 24 — — 57 — -25 to +70 0.9
subject to alterations

172+0,5 8±0,1
150+0,5

Curves
Ø4,2±0,1

[Pa]

[in H O]
2

200

Ø152,5 9 11
160
0,6

162±0,2 38+0,5

Blade terminal 2.8 x 0.5 mm "V" 


120
0,4

80

A
0,2

40

0 50 100 150 200 [CFM]

100 200 300 400 [m3/h]

50 Hz 60 Hz

16
Guard grille Connection lead
p. 368 f. p. 374
information
General
AC axial fans
Ø 143

AC axial fans
– Material: – Condensate discharges: None
Wall ring: Die-cast aluminium, – Mode of operation:
coated in black Continuous operation (S1)
Blades: Sheet steel, coated in black – Bearings: Maintenance-free ball bearings
Rotor: Open, coated in black – Motor protection: TOP wired internally

AC axial
S series
– Number of blades: 5 – Electrical connection: Blade terminal
– Direction of air flow: "V", exhaust over 2.8 x 0.5 mm (operating capacitor
struts connected)
– Direction of rotation: Counter-clockwise, – Protection class: I
seen on rotor – Product conforming to standards:
– Type of protection: IP 20 EN 60335-1, CE

AC axial
K series
– Insulation class: "B" – Approvals: VDE, UL, CSA, CCC, GOST
– Mounting position: Any

Max. operative range


Sound pressure level

Perm. amb. temp.


Nominal voltage

AC axial
A series
Current draw
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Mass
Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg

EC axial fans
1~ 115 50 375 2800 24 — — 55 — -25 to +70
W2E143 -AA15 -01 M2E 052-BF B
1~ 115 60 440 3300 26 — — 60 — -25 to +70 1.0
1~ 230 50 375 2800 24 — — 55 — -25 to +70
W2E143 -AA09 -01 M2E 052-BF B
1~ 230 60 440 3300 26 — — 60 — -25 to +70 1.0
subject to alterations

EC axial
S series
51±0,3 171,5±0,4
+0,1 +0,1
7,2 -0,3 7,2 -0,3 162

Q-motor
25±1
Ø4,6 / 4,75-0,4
165±0,4

Curves
8,8

96

76±1
±
[Pa]

[in H O]

1
2

ESM
200

 "V" Blade terminal 2.8 x 0.5 mm 86±1


160
EC-SYSTEMS
0,6

120
0,4

Accessories

80

B
0,2

40
Technology

0 50 100 150 200 250 [CFM]

100 200 300 400 [m3/h]

50 Hz 60 Hz
Contacts

17
Guard grille Connection lead
p. 368 f. p. 374
AC axial fans
Ø 143

– Material: – Condensate discharges: None


Wall ring: Die-cast aluminium, – Mode of operation:
coated in black Continuous operation (S1)
Blades: Sheet steel, coated in black – Bearings: Maintenance-free ball bearings
Rotor: Open, coated in black – Motor protection: TOP wired internally
– Number of blades: 5 – Electrical connection: Blade terminal
– Direction of air flow: "V", exhaust over 2.8 x 0.5 mm (operating capacitor
struts connected)
– Direction of rotation: Counter-clockwise, – Protection class: I
seen on rotor – Product conforming to standards:
– Type of protection: IP 20 EN 60335-1, CE
– Insulation class: "B" – Approvals: VDE, UL, CSA, CCC, GOST
– Mounting position: Any

Max. operative range


Sound pressure level

Perm. amb. temp.


Nominal voltage

Current draw
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Mass
Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg

1~ 115 50 420 2800 26 — — 54 — -25 to +60


W2E 143-AB15 -01 M2E 052-BF A
1~ 115 60 500 3300 29 — — 58 — -25 to +75 1.0
1~ 230 50 420 2800 26 — — 54 — -25 to +60
W2E 143-AB09 -01 M2E 052-BF A
1~ 230 60 500 3300 29 — — 58 — -25 to +75 1.0
subject to alterations

51±0,3 171,5±0,4
+0,1 +0,1
7,2 -0,3 7,2 -0,3 162
25±1
Ø4,6 / 4,75-0,4

Curves
165±0,4

[Pa]

[in H O]
2
8,8

96

76±1

200
±1

160
 "V" Blade terminal 2.8 x 0.5 mm 86±1
0,6

120
0,4

80

A
0,2

40

0 50 100 150 200 250 [CFM]

100 200 300 400 [m3/h]

50 Hz 60 Hz

18
Guard grille Connection lead
p. 368 f. p. 374
information
General
AC axial fans
Ø 200

AC axial fans
– Material: – Mode of operation:
Wall ring: Die-cast aluminium Continuous operation (S1)
Blades: Sheet steel, coated in black – Bearings: Maintenance-free ball bearings
Rotor: Coated in black – Motor protection: TOP wired internally
– Number of blades: 7 – Electrical connection: Terminal strips

AC axial
S series
– Direction of air flow: "V", exhaust over (operating capacitor connected)
struts – Protection class: I
– Direction of rotation: Counter-clockwise, – Product conforming to standards:
seen on rotor EN 60335-1, CE
– Type of protection: IP 44 – Approvals: VDE, UL, CSA, CCC;
– Insulation class: "B" B also GOST

AC axial
K series
– Mounting position: Any
– Condensate discharges: None

Max. operative range


Sound pressure level

Perm. amb. temp.


Nominal voltage

AC axial
A series
Current draw
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Mass
Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg

EC axial fans
1~ 115 50 925 2550 64 0.58 5.0 /220 59 100 -25 to +60
W2E 200-HK86 -01 M2E 068-BF B
1~ 115 60 1030 2800 80 0.70 5.0 /220 61 120 -25 to +65 2.0
1~ 230 50 925 2550 64 0.29 1.5 /400 59 100 -25 to +60
W2E 200-HK38 -01 M2E 068-BF B
1~ 230 60 1030 2800 80 0.35 1.5 /400 61 120 -25 to +65 2.0
1~ 230 50 450 1370 30 0.21 — 40 50 -25 to +70
W4S 200-HK04 -01 M4S 068-BF C
1~ 230 60 525 1590 26 0.18 — 44 50 -25 to +80 2.0

EC axial
S series
subject to alterations

80 ±0,3
W2E 200-HK 7
(1)
2,6
Protruding capacitor

Q-motor
22
5

(1)
ca. 2
12

Curves
[Pa]

[in H O]
2

ESM
PE N L

160
Ø4,5 +0,2
0,6

140
240 4 "V" 
260
EC-SYSTEMS

120
80 ±0,3
W4S 200-HK 7
0,4

100
2,6
80
22

Accessories
5

60
12
0,2

40

C PE N L
Technology

20
Ø 4,5 +0,2

0 100 200 300 400 500 [CFM]


240 4 "V" 
200 400 600 800 [m3/h]
260
50 Hz 60 Hz
Contacts

19
Guard grille Capacitor
p. 369 p. 382 f.
AC diagonal fans
Ø 208

– Material: – Mode of operation:


Wall ring: Die-cast aluminium Continuous operation (S1)
Blades: Plastic PA – Bearings: Maintenance-free ball bearings
Rotor: Coated in black – Motor protection: A Without TOP,
– Number of blades: 5 B TOP wired internally

– Direction of air flow: "V", exhaust over – Electrical connection: Terminal strips
struts (operating capacitor connected)
– Direction of rotation: Counter-clockwise, – Protection class: I
seen on rotor – Product conforming to standards:
– Type of protection: IP 44 EN 60335-1, B also CE
– Insulation class: "F" – Approvals: VDE, CCC, GOST
– Mounting position: Any
– Condensate discharges: None

Max. operative range


Sound pressure level

Perm. amb. temp.


Nominal voltage

Current draw
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Mass
Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg

3~ 400 Y 50 820 2740 60 0.15 — 67 135 -25 to +70


W2D208-BA02 -01 M2D 068-CF A
3~ 400 Y 60 920 3090 80 0.15 — 70 165 -25 to +70 2.8
1~ 115 50 815 2750 67 0.70 6.0 /220 68 135 -25 to +72
W2E 208-BA86 -01 M2E 068-CF B
1~ 115 60 925 3100 87 0.78 6.0 /220 70 165 -25 to +72 2.8
1~ 230 50 815 2750 67 0.33 1.5 /450 68 135 -25 to +72
W2E 208-BA20 -01 M2E 068-CF B
1~ 230 60 925 3100 87 0.39 1.5 /450 70 165 -25 to +72 2.8
subject to alterations

n P1 LpA n P1 LpA
[rpm] [W] [dB(A)] [rpm] [W] [dB(A)]
A 1 3090 80 70 B 1 3100 87 70
A 2 2990 93 69 B 2 2990 100 70
A 3 2960 96 69 B 3 2960 102 69
A 4 2990 92 70 B 4 3020 97 70

Curves
[Pa]

[in H O]
2

160
A B
0,6

140
4

120
3
"V" 
0,4

100

Section C-C 2
80
Ø4,5
Ø4,5

60
0,2

10 ±0,3 10 ±0,3 40

20

1
0 100 200 300 400 500 [CFM]

200 400 600 800 [m3/h]

50 Hz 60 Hz

20
Guard grille Capacitor
p. 367 p. 382 f.
information
General
AC axial fans
Ø 250

AC axial fans
– Material: – Mode of operation:
Wall ring: Die-cast aluminium Continuous operation (S1)
Blades: Sheet steel, coated in black – Bearings: Maintenance-free ball bearings
Rotor: Coated in black – Motor protection: TOP wired internally
– Number of blades: 7 – Electrical connection: Terminal strips

AC axial
S series
– Direction of air flow: "V", exhaust over (operating capacitor connected)
struts – Protection class: I
– Direction of rotation: Counter-clockwise, – Product conforming to standards:
seen on rotor EN 60335-1, CE
– Type of protection: IP 44 – Approvals: VDE, UL, CSA, CCC, GOST
– Insulation class: "F"

AC axial
K series
– Mounting position: Any
– Condensate discharges: None

Max. operative range


Sound pressure level

Perm. amb. temp.


Nominal voltage

AC axial
A series
Current draw
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Mass
Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg

EC axial fans
1~ 230 50 1865 2550 127 0.56 4.0 /400 69 100 -25 to +60
W2E 250-HL06 -01 M2E 068-CF C
1~ 230 60 1970 2700 180 0.79 4.0 /400 70 100 -25 to +45 2.0
subject to alterations

EC axial
S series
80 ±0,3
7
2,6

Q-motor
28
0

Curves
12
[Pa]

[in H O]
2

ESM
140
PE N L
0,5

Ø5,4 +0,2

120
EC-SYSTEMS
0,4

100 295 4
C
320
80 "V" 
0,3

Accessories

60
0,2

40
0,1

20
Technology

0 200 400 600 800 [CFM]

400 800 1200 1600 [m3/h]

50 Hz 60 Hz
Contacts

21
Guard grille Capacitor
p. 369 p. 382 f.
22
AC axial fans S series

AC axial fans, S series


AC axial fans, S series

Ø 500 - Ø 910
Ø 200 - Ø 450

23
74
24

Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
S series, Ø 200

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 9
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

3~ 230/400 50 890 2600 68 0.29/0.17 — 65 140 -25 to +45


*2D 200 (1) M2D 068-BF A
3~ 230/400 60 990 2900 70 0.23/0.13 — 68 140 -25 to +70 1.6 C1)/C2)
1~ 230 50 890 2600 64 0.30 1.5 /400 65 150 -25 to +70
*2E 200 M2E 068-BF B
1~ 230 60 990 2900 78 0.34 1.5 /400 68 150 -25 to +70 1.4 A1)
3~ 230/400 50 500 1440 20 0.12/0.07 — 43 70 -25 to +80
*4D 200 (1) M4D 068-BF C
3~ 230/400 60 600 1690 20 0.10/0.06 — 47 90 -25 to +90 1.4 C1)/C2)
1~ 230 50 470 1370 30 0.21 — 42 50 -25 to +75
*4S 200 M4S 068-BF D
1~ 230 60 540 1580 27 0.19 — 46 50 -25 to +80 1.2 B)
subject to alterations (1) 230 VAC ∆ / 400 VAC Y

n P1 I
Curves [rpm] [W] [A]

A 1 2540 70 0.29/0.17
[Pa]

[in H O]
2

A 2 2470 74 0.29/0.17
140 C 1 1430 21 0.12/0.07
C 2 1420 23 0.12/0.07
0,5

120
0,4

100

80 2
0,3

60 A
C
0,2

40 1

2
0,1

20 1

0 100 200 300 400 500 [CFM]

200 400 600 800 [m3/h]

50 Hz 60 Hz

24
information
General
AC axial fans
– Motor protection: A C Without TOP, B D TOP wired internally
– Cable exit: A C Lateral, B D variable
– Protection class: I
– Product conforming to standards: EN 60335-1, B D also CE
– Approvals: B CCC

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle (1) for full nozzle for short nozzle

EC axial fans
"V" A2D 200-AH18 -01 W2D 200-CH18 -01 S2D 200-BH18 -01 S2D 200-AH18 -01
"A" A2D 200-AI18 -01 W2D 200-CI18 -01 S2D 200-BI18 -01 S2D 200-AI18 -01
"V" A2E 200-AH38 -01 W2E 200-CH38 -01 S2E 200-BH38 -01 S2E 200-AH38 -01
"A" A2E 200-AI38 -01 W2E 200-CI38 -01 S2E 200-BI38 -01 S2E 200-AI38 -01
"V" A4D 200-AH14 -01 W4D 200-CH14 -01 S4D 200-BH14 -01 S4D 200-AH14 -01
"A" A4D 200-AI14 -01 W4D 200-CI14 -01 S4D 200-BI14 -01 S4D 200-AI14 -01
"V" A4S 200-AH04 -01 W4S 200-CH04 -01 S4S 200-BH04 -01 S4S 200-AH04 -01

EC axial
S series
"A" A4S 200-AI04 -01 W4S 200-CI04 -01 S4S 200-BI04 -01 S4S 200-AI04 -01
(1) Increased noise levels in "V" direction of air flow

Q-motor
n P1 I
Curves [rpm] [W] [A]

B 1 2555 67 0.31
[Pa]

[in H O]
2

ESM
B 2 2465 70 0.32
160
D 1 1360 31 0.22
0,6

D 2 1350 31 0.22
140 EC-SYSTEMS

120
0,4

100

80 2
Accessories

60 B
D
0,2

40 1

2
Technology

20 1

0 100 200 300 400 500 [CFM]

200 400 600 800 [m3/h]

50 Hz 60 Hz
Contacts

25
Drawings Guard grille Wall ring Terminal box Capacitor Electr. connections
p. 26 f. p. 362 f. p. 372 f. p. 381 p. 382 f. p. 416 f.
AC axial fans
S series, Ø 200, drawings of directions of air flow "V" and "A"

Type
Without attachments
A2D 200-AH18 -01 "V"
Depth of screw
A2D 200-AI18 -01 "A"
39±3 max. 5 mm
17 ±5 58 ±0,2 A2E 200-AH38 -01 "V"
A2E 200-AI38 -01 "A"
2 M4 A4D 200-AH14 -01 "V"
Brass lead tips
A4D 200-AI14 -01 "A"
Ø27 -0,1

Ø197 -2
Ø92

A4S 200-AH04 -01 "V"

90˚
27

A4S 200-AI04 -01 "A"


6
85
450 ±20
62 ±3

 "V"
"A" 

Type
With full round nozzle
W2D 200-CH18 -01 "V"
9 80 W2D 200-CI18 -01 "A"
5 W2E 200-CH38 -01 "V"
W2E 200-CI38 -01 "A"
W4D 200-CH14 -01 "V"
1,25

W4D 200-CI14 -01 "A"


250 W4S 200-CH04 -01 "V"
W4S 200-CI04 -01 "A"
Ø200
Ø280

15˚
7

˚
60
6x

 "V"
"A" 

Type
With guard grille for full nozzle
S2D 200-BH18 -01 "V"
3,9 4,5 S2D 200-BI18 -01 "A"
S2E 200-BH38 -01 "V"
S2E 200-BI38 -01 "A"
S4D 200-BH14 -01 "V"
S4D 200-BI14 -01 "A"
S4S 200-BH04 -01 "V"
245

S4S 200-BI04 -01 "A"

 "V"
"A" 

26
information
General
AC axial fans
Type
With guard grille for short nozzle
S2D 200-AH18 -01 "V"
23 S2D 200-AI18 -01 "A"
13 ±5 7 S2E 200-AH38 -01 "V"

AC axial
S series
S2E 200-AI38 -01 "A"
S4D 200-AH14 -01 "V"
S4D 200-AI14 -01 "A"
S4S 200-AH04 -01 "V"
229

260
S4S 200-AI04 -01 "A"

AC axial
K series
3,9
46

AC axial
A series
 "V"
"A" 

EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

27
AC axial fans
S series, Ø 250

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 7
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

3~ 230/400 50 1830 2500 100 0.34/0.20 — 69 150 -25 to +65


*2D 250 (1) M2D 068-CF A
3~ 230/400 60 1950 2650 140 0.40/0.23 — 70 150 -25 to +45 2.1 C1)/C2)
1~ 230 50 1820 2450 115 0.51 3.0 /400 69 120 -25 to +65
*2E 250 M2E 068-CF B
1~ 230 60 1970 2600 150 0.66 3.0 /400 71 85 -25 to +50 1.9 A1)
3~ 230/400 50 1010 1400 25 0.12/0.07 — 54 70 -25 to +85
*4D 250 (1) M4D 068-CF C
3~ 230/400 60 1140 1580 32 0.12/0.07 — 57 70 -25 to +80 1.9 C1)/C2)
1~ 230 50 1010 1400 42 0.19 1.5 /400 54 80 -25 to +55
*4E 250 M4E 068-BF D
1~ 230 60 1200 1630 45 0.20 1.5 /400 58 100 -25 to +70 1.9 A1)
1~ 230 50 1000 1390 69 0.53 — 54 80 -25 to +50
*4S 250 M4S 068-CF E
1~ 230 60 1160 1600 63 0.45 — 58 80 -25 to +65 1.7 B)
subject to alterations (1) 230 VAC ∆ / 400 VAC Y

n P1 I
Curves [rpm] [W] [A]

A 1 2455 106 0.34/0.20


[Pa]

[in H O]
2

A 2 2310 125 0.38/0.22


140 D 1 1370 43 0.20
D 2 1360 45 0.20
0,5

120 E 1 1370 71 0.53


E 2 1360 73 0.53
0,4

100 2
A

80 E
0,3

60
0,2

40
2
D
0,1

20 1
1

0 200 400 600 800 [CFM]

400 800 1200 1600 [m3/h]

50 Hz 60 Hz

28
information
General
AC axial fans
– Motor protection: A C Without TOP, B D E TOP wired internally
– Cable exit: A C E Lateral, B D variable
– Protection class: I
– Product conforming to standards: EN 60335-1, B D E also CE
– Approvals: A B D CCC; D also GOST

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle (1) for full nozzle for short nozzle

EC axial fans
"V" A2D 250-AH02 -01 W2D 250-CH02 -01 S2D 250-BH02 -01 S2D 250-AH02 -01
"A" A2D 250-AI02 -01 W2D 250-CI02 -01 S2D 250-BI02 -01 S2D 250-AI02 -01
"V" A2E 250-AL06 -01 W2E 250-CL06 -01 S2E 250-BL06 -01 S2E 250-AL06 -01
"A" A2E 250-AM06 -01 W2E 250-CM06 -01 S2E 250-BM06 -01 S2E 250-AM06 -01
"V" A4D 250-AH22 -01 W4D 250-CH22 -01 S4D 250-BH22 -01 S4D 250-AH22 -01
"A" A4D 250-AI22 -01 W4D 250-CI22 -01 S4D 250-BI22 -01 S4D 250-AI22 -01
"V" A4E 250-AH02 -01 W4E 250-CH02 -01 S4E 250-BH02 -01 S4E 250-AH02 -01

EC axial
S series
"A" A4E 250-AI02 -01 W4E 250-CI02 -01 S4E 250-BI02 -01 S4E 250-AI02 -01
"V" A4S 250-AH02 -01 W4S 250-CH02 -01 S4S 250-BH02 -01 S4S 250-AH02 -01
"A" A4S 250-AI02 -01 W4S 250-CI02 -01 S4S 250-BI02 -01 S4S 250-AI02 -01
(1) Increased noise levels in "V" direction of air flow

Q-motor
n P1 I
Curves [rpm] [W] [A]

B 1 2455 116 0.51


[Pa]

[in H O]
2

ESM
B 2 2290 132 0.57
140 C 1 1375 27 0.12/0.07
C 2 1350 30 0.12/0.07
0,5

120
EC-SYSTEMS
0,4

100
2
B
80
0,3

Accessories

60 C
0,2

40
2
0,1

20 1
Technology

0 200 400 600 800 [CFM]

400 800 1200 1600 [m3/h]

50 Hz 60 Hz
Contacts

29
Drawings Guard grille Wall ring Terminal box Capacitor Electr. connections
p. 30 f. p. 362 f. p. 372 f. p. 381 p. 382 f. p. 416 f.
AC axial fans
S series, Ø 250, drawings of directions of air flow "V" and "A"

Type
Without attachments a c
A2D 250-AH02 -01 "V" 72.0 18.0
Depth of screw
A2D 250-AI02 -01 "A" 72.0 21.0
c ±5 34 ±3 max. 5 mm
A2E 250-AL06 -01 "V" 72.0 18.0
58 ±0,2 A2E 250-AM06 -01 "A" 72.0 27.0
Brass lead tips 2 M4 A4D 250-AH22 -01 "V" 72.0 18.0
A4D 250-AI22 -01 "A" 72.0 27.0
Ø27-0,1

Ø251-2

A4E 250-AH02 -01 "V" 62.0 14.0


Ø92

90˚
27

A4E 250-AI02 -01 "A" 62.0 22.0


6 A4S 250-AH02 -01 "V" 72.0 18.0
85
450 ±20 A4S 250-AI02 -01 "A" 72.0 23.0

a ±3

 "V"
"A" 

Type
With full round nozzle
W2D 250-CH02 -01 "V"
9 87 W2D 250-CI02 -01 "A"
6
W2E 250-CL06 -01 "V"
W2E 250-CM06 -01 "A"
W4D 250-CH22 -01 "V"
1,25

295 W4D 250-CI22 -01 "A"


W4E 250-CH02 -01 "V"
W4E 250-CI02 -01 "A"
Ø257
Ø320

W4S 250-CH02 -01 "V"


15˚
7

W4S 250-CI02 -01 "A"

˚
60
6x
 "V"
"A" 

Type
With guard grille for full nozzle h k
S2D 250-BH02 -01 "V" 5.0 10.0
3,9 S2D 250-BI02 -01 "A" 0 0
h 4,5
S2E 250-BL06 -01 "V" 5.0 10.0
S2E 250-BM06 -01 "A" 0 0
k S4D 250-BH22 -01 "V" 5.0 10.0
S4D 250-BI22 -01 "A" 0 0
S4E 250-BH02 -01 "V" 5.0 10.0
S4E 250-BI02 -01 "A" 0 0
290

S4S 250-BH02 -01 "V" 5.0 10.0


S4S 250-BI02 -01 "A" 0 0

 "V"
"A" 

30
information
General
AC axial fans
Type
With guard grille for short nozzle m n u v
S2D 250-AH02 -01 "V" 50.0 5.0 14.0 34.0
v S2D 250-AI02 -01 "A" 45.0 0 17.0 34.0
u 7 S2E 250-AL06 -01 "V" 50.0 5.0 14.0 34.0

AC axial
S series
S2E 250-AM06 -01 "A" 45.0 0 23.0 34.0
S4D 250-AH22 -01 "V" 50.0 5.0 14.0 34.0
S4D 250-AI22 -01 "A" 45.0 0 23.0 34.0
S4E 250-AH02 -01 "V" 50.0 5.0 10.0 24.0

300
S4E 250-AI02 -01 "A" 45.0 0 18.0 24.0
271

S4S 250-AH02 -01 "V" 50.0 5.0 14.0 34.0

AC axial
K series
S4S 250-AI02 -01 "A" 45.0 0 19.0 34.0
n

3,9
m

AC axial
A series
 "V"
"A" 

EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

31
AC axial fans 2-pole
S series, Ø 300

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

3~ 230/400 50 3130 2580 210 0.62/0.36 — 72 200 -25 to +55


*2D 300 (1) M2D 074-DF A
3~ 230/400 60 3350 2750 300 0.83/0.48 — 73 125 -25 to +40 3.0 C1)/C2)
1~ 230 50 3410 2700 230 1.10 8.0 /400 73 200 -25 to +50
*2E 300 M2E 074-DF B
1~ 230 60 3740 3000 350 1.55 8.0 /400 76 50 -25 to +40 3.0 A1)
subject to alterations (1) 230 VAC ∆ / 400 VAC Y

n P1 I
Curves [rpm] [W] [A]

A 1 2530 228 0.68/0.39


[Pa]

[in H O]
2

A 2 2400 273 0.78/0.45


200

160
0,6

120
A
0,4

80
0,2

40

0 500 1000 1500 2000 [CFM]

1000 2000 3000 [m3/h]

50 Hz 60 Hz

32
information
General
AC axial fans
– Motor protection: A Without TOP, B TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, B also CE
– Approvals: CCC

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A2D 300-AP02 -01 W2D 300-CP02 -30 S2D 300-BP02 -30 S2D 300-AP02 -30
"A" A2D 300-AP02 -02 W2D 300-CP02 -31 S2D 300-BP02 -31 S2D 300-AP02 -31
"V" A2E 300-AP02 -01 W2E 300-CP02 -30 S2E 300-BP02 -30 S2E 300-AP02 -30
"A" A2E 300-AP02 -02 W2E 300-CP02 -31 S2E 300-BP02 -31 S2E 300-AP02 -31

EC axial
S series
Q-motor
n P1 I
Curves [rpm] [W] [A]

B 1 2680 252 1.11


[Pa]

[in H O]
2

ESM
B 2 2560 290 1.27
200

160
EC-SYSTEMS
0,6

120
0,4

Accessories

80

B
0,2

40
Technology

0 500 1000 1500 2000 [CFM]

1000 2000 3000 [m3/h]

50 Hz 60 Hz
Contacts

33
Drawings Guard grille Wall ring Terminal box Capacitor Electr. connections
p. 34 f. p. 362 f. p. 372 f. p. 381 p. 382 f. p. 416 f.
AC axial fans 2-pole
S series, Ø 300, drawings of directions of air flow "V" and "A"

Type
Without attachments
A2D 300-AP02 -01 "V"
- 0 + Depth of screw
A2D 300-AP02 -02 "A"
max. 10 mm
30 ±3 38 ±3 A2E 300-AP02 -01 "V"
A2E 300-AP02 -02 "A"
M4
Brass lead tips M6
5
Ø298 ±2

4x90˚
Ø75

Ø102

37

6
85
450 ±20

104 ±2 90 ±0,2

 "V"
"A" 

Type
With full round nozzle
W2D 300-CP02 -30 "V"
80 W2D 300-CP02 -31 "A"
11 W2E 300-CP02 -30 "V"
W2E 300-CP02 -31 "A"

380
Ø326
Ø397

15˚
9
˚
60
6x

0
 "V"
"A" 

Type
With guard grille for full nozzle
S2D 300-BP02 -30 "V"
0 S2D 300-BP02 -31 "A"
5 6,5 S2E 300-BP02 -30 "V"
S2E 300-BP02 -31 "A"
360

 "V"
"A" 

34
0
5

54
18
50

 "V"
"A" 
324
With guard grille for short nozzle

6,5

360
S2E
S2E
S2D
S2D
Type

300-AP02
300-AP02
300-AP02
300-AP02

-31
-30
-31
-30

"V"
"V"

"A"
"A"

35
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans 4-pole
S series, Ø 300

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

3~ 230/400 50 1860 1370 60 0.29/0.17 — 57 90 -25 to +45


*4D 300 (1) M4D 068-CF A
3~ 230/400 60 2080 1540 75 0.26/0.15 — 60 60 -25 to +40 1.9 C1)/C2)
1~ 230 50 1740 1400 68 0.30 2.0 /400 59 80 -25 to +60
*4E 300 M4E 068-CF B
1~ 230 60 2040 1630 92 0.41 2.0 /400 63 70 -25 to +45 1.9 A1)
subject to alterations (1) 230 VAC ∆ / 400 VAC Y

n P1 I
Curves [rpm] [W] [A]

1350 66 0.29/0.17
[Pa]

[in H O]

A 1
2

A 2 1260 88 0.33/0.19
100

80 2
0,3

60
0,2

40
0,1

20

0 250 500 750 1000 [CFM]

500 1000 1500 [m3/h]

50 Hz 60 Hz

36
information
General
AC axial fans
– Motor protection: A Without TOP, B TOP wired internally
– Cable exit: A Axial, B variable
– Protection class: I
– Product conforming to standards: EN 60335-1, B also CE
– Approvals: CCC; B also GOST

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A4D 300-AP28 -01 W4D 300-CP28 -30 S4D 300-BP28 -30 S4D 300-AP28 -30
"A" A4D 300-AP28 -02 W4D 300-CP28 -31 S4D 300-BP28 -31 S4D 300-AP28 -31
"V" A4E 300-AP26 -01 W4E 300-CP26 -30 S4E 300-BP26 -30 S4E 300-AP26 -30
"A" A4E 300-AP26 -02 W4E 300-CP26 -31 S4E 300-BP26 -31 S4E 300-AP26 -31

EC axial
S series
Q-motor
n P1 I
Curves [rpm] [W] [A]

1390 72 0.32
[Pa]

[in H O]

B 1
2

ESM
B 2 1290 88 0.39
100

80 2
EC-SYSTEMS
B
0,3

60
0,2

Accessories

40
0,1

20
Technology

0 250 500 750 1000 [CFM]

500 1000 1500 [m3/h]

50 Hz 60 Hz
Contacts

37
Drawings Guard grille Wall ring Terminal box Capacitor Electr. connections
p. 38 f. p. 362 f. p. 372 f. p. 381 p. 382 f. p. 416 f.
AC axial fans 4-pole
S series, Ø 300, drawings of directions of air flow "V" and "A"

Type
Without attachments c
A4D 300-AP28 -01 "V" 13.0
- 0 + Depth of screw
A4D 300-AP28 -02 "A" -7.0
max. 5 mm
c ±3 60 ±3 A4E 300-AP26 -01 "V" 13.0
A4E 300-AP26 -02 "A" -7.0
M4
Brass lead tips M4
2

4x90˚
Ø300-2
Ø27

Ø92

27

6
85
450 ±20

73 ±2 58 ±0,2

 "V"
"A" 

Type
With full round nozzle k
W4D 300-CP28 -30 "V" 0.0
80 W4D 300-CP28 -31 "A" 30.0
11 W4E 300-CP26 -30 "V" 0.0
W4E 300-CP26 -31 "A" 30.0

380
Ø326
Ø397

15˚
9
˚
60
6x

k
 "V"
"A" 

Type
With guard grille for full nozzle k
S4D 300-BP28 -30 "V" 0.0
k S4D 300-BP28 -31 "A" 30.0
4 4,5 S4E 300-BP26 -30 "V" 0.0
S4E 300-BP26 -31 "A" 30.0
360

 "V"
"A" 

38
information
General
AC axial fans
Type
With guard grille for short nozzle k u v
S4D 300-AP28 -30 "V" 0.0 23.0 23.0
50 S4D 300-AP28 -31 "A" 30.0 29.0 49.0
4 4,5
S4E 300-AP26 -30 "V" 0.0 23.0 23.0

AC axial
S series
S4E 300-AP26 -31 "A" 30.0 29.0 49.0
k
329,5

360

AC axial
K series
u

AC axial
A series
v

 "V"
"A" 

EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

39
AC axial fans
S series, Ø 315

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

3~ 230/400 50 2450 1400 85 0.45/0.26 — 60 120 -25 to +55


*4D 315 (1) M4D 068-DF A
3~ 230/400 60 2810 1620 110 0.42/0.24 — 64 120 -25 to +55 2.4 C1)/C2)
1~ 230 50 2440 1410 102 0.52 4.0 /400 59 120 -25 to +55
*4E 315 M4E 068-DF B
1~ 230 60 2840 1650 120 0.53 4.0 /400 64 120 -25 to +55 2.4 A1)
1~ 230 50 1650 950 65 0.33 2.0 /400 51 70 -25 to +50
*6E 315 M6E 068-DF C
1~ 230 60 1950 1120 68 0.30 2.0 /450 55 80 -25 to +60 2.4 A1)
subject to alterations (1) 230 VAC ∆ / 400 VAC Y

n P1 I
Curves [rpm] [W] [A]

A 1 1400 90 0.45/0.26
[Pa]

[in H O]
2

A 2 1380 103 0.47/0.27

120
0,4

100

80
0,3

60 2
0,2

40
0,1

1
20

0 250 500 750 1000 1250 1500 [CFM]

600 1200 1800 2400 [m3/h]

50 Hz 60 Hz

40
Drawings
p. 42 f.
information
General
AC axial fans
– Motor protection: A Without TOP, B C TOP wired internally
– Cable exit: Axial
– Protection class: I
– Product conforming to standards: EN 60335-1, B C also CE
– Approvals: CCC; A also GOST

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"
Without With full With guard grille With guard grille In-line duct fan
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A4D 315-AP10 -01 W4D 315-CP10 -30 S4D 315-BP10 -30 S4D 315-AP10 -30 W4D 315-IP10 -01
"A" A4D 315-AP10 -02 W4D 315-CP10 -31 S4D 315-BP10 -31 S4D 315-AP10 -31 —
"V" A4E 315-AP18 -01 W4E 315-CP18 -30 S4E 315-BP18 -30 S4E 315-AP18 -30 W4E 315-IP18 -01
"A" A4E 315-AP18 -02 W4E 315-CP18 -31 S4E 315-BP18 -31 S4E 315-AP18 -31 —
"V" A6E 315-AP02 -01 W6E 315-CP02 -30 S6E 315-BP02 -30 S6E 315-AP02 -30 —
"A" A6E 315-AP02 -02 W6E 315-CP02 -31 S6E 315-BP02 -31 S6E 315-AP02 -31 —

EC axial
S series
Q-motor
n P1 I
Curves [rpm] [W] [A]

B 1 1400 108 0.54


[Pa]

[in H O]
2

ESM
B 2 1380 120 0.57

120 C 1 945 63 0.33


C 2 930 66 0.33
0,4

100
EC-SYSTEMS

80
0,3

60 2
Accessories
0,2

40

2
0,1

C 1
20
Technology

0 250 500 750 1000 1250 1500 [CFM]

600 1200 1800 2400 [m3/h]

50 Hz 60 Hz
Contacts

41
Guard grille Streamer Wall ring Terminal box Capacitor Electr. connections
p. 362 f. p. 371 p. 372 f. p. 381 p. 382 f. p. 416 f.
AC axial fans
S series, Ø 315, drawings of directions of air flow "V" and "A"

Type
Without attachments c
A4D 315-AP10 -01 "V" 5.0
- 0 + Depth of screw
A4D 315-AP10 -02 "A" -7.0
max. 5 mm
c ±3 85 A4E 315-AP18 -01 "V" 5.0
A4E 315-AP18 -02 "A" -7.0
M4
Brass lead tips A6E 315-AP02 -01 "V" 5.0
M4
2 A6E 315-AP02 -02 "A" -7.0

4x90˚
Ø312 ±2
Ø27

Ø92

27

6
85
450 ±20

83 ±2 58 ±0,2

 "V"
"A" 

Type
With full round nozzle
W4D 315-CP10 -30 "V"
74 W4D 315-CP10 -31 "A"
11 W4E 315-CP18 -30 "V"
W4E 315-CP18 -31 "A"
W6E 315-CP02 -30 "V"
380 W6E 315-CP02 -31 "A"
Ø347
Ø397

15˚
9
˚
60
6x

33
 "V"
"A" 

Type
With guard grille for full nozzle
S4D 315-BP10 -30 "V"
30 S4D 315-BP10 -31 "A"
4,5 6,5 S4E 315-BP18 -30 "V"
S4E 315-BP18 -31 "A"
S6E 315-BP02 -30 "V"
S6E 315-BP02 -31 "A"
375

 "V"
"A" 

42
information
General
AC axial fans
Type
With guard grille for short nozzle u
S4D 315-AP10 -30 "V" 40.0
80 S4D 315-AP10 -31 "A" 28.0
4,5 6,5
S4E 315-AP18 -30 "V" 40.0

AC axial
S series
S4E 315-AP18 -31 "A" 28.0

30 S6E 315-AP02 -30 "V" 40.0


S6E 315-AP02 -31 "A" 28.0
336,5

375

AC axial
K series
u

AC axial
A series
33

 "V"
"A" 

Type
In-line duct fan

EC axial fans
W4D 315-IP10 -01 "V"
W4E 315-IP18 -01 "V"

EC axial
S series
Q-motor
 "V"

ESM
EC-SYSTEMS
Accessories
Technology
Contacts

43
AC axial fans
S series, Ø 330

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

3~ 230/400 50 2800 1390 100 0.45/0.26 — 59 120 -25 to +55


*4D 330 (1) M4D 068-DF A
3~ 230/400 60 3180 1570 130 0.42/0.24 — 63 120 -25 to +45 2.6 C1)/C2)
1~ 230 50 2830 1390 120 0.57 4.0 /400 63 90 -25 to +50
*4E 330 M4E 068-DF B
1~ 230 60 3230 1600 140 0.60 4.0 /400 67 75 -25 to +40 2.5 A1)
1~ 230 50 1940 940 65 0.33 2.0 /400 49 60 -25 to +50
*6E 330 M6E 068-DF C
1~ 230 60 2280 1100 72 0.32 2.0 /450 53 70 -25 to +65 2.5 A1)
subject to alterations (1) 230 VAC ∆ / 400 VAC Y

n P1 I
Curves [rpm] [W] [A]

A 1 1370 102 0.45/0.26


[Pa]

[in H O]
2

A 2 1325 126 0.48/0.28


0,5

120
0,4

100

80
0,3

2
60
0,2

40
0,1

1
20

0 500 1000 1500 [CFM]

500 1000 1500 2000 2500 3000 [m3/h]

50 Hz 60 Hz

44
information
General
AC axial fans
– Motor protection: A Without TOP, B C TOP wired internally
– Cable exit: Axial
– Protection class: I
– Product conforming to standards: EN 60335-1, B C also CE
– Approvals: B C CCC

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A4D 330-AP10 -01 W4D 330-CP10 -30 S4D 330-BP10 -30 S4D 330-AP10 -30
"A" A4D 330-AP10 -02 W4D 330-CP10 -31 S4D 330-BP10 -31 S4D 330-AP10 -31
"V" A4E 330-AP18 -01 W4E 330-CP18 -30 S4E 330-BP18 -30 S4E 330-AP18 -30
"A" A4E 330-AP18 -02 W4E 330-CP18 -31 S4E 330-BP18 -31 S4E 330-AP18 -31
"V" A6E 330-AP02 -01 W6E 330-CP02 -30 S6E 330-BP02 -30 S6E 330-AP02 -30
"A" A6E 330-AP02 -02 W6E 330-CP02 -31 S6E 330-BP02 -31 S6E 330-AP02 -31

EC axial
S series
Q-motor
n P1 I
Curves [rpm] [W] [A]

B 1 1375 122 0.58


[Pa]

[in H O]
2

ESM
B 2 1325 140 0.64
C 1 925 68 0.34
0,5

120
C 2 910 70 0.35
EC-SYSTEMS
0,4

100

80
0,3

2
Accessories

60
B
0,2

40

2
C
0,1

1
20
Technology

0 500 1000 1500 [CFM]

500 1000 1500 2000 2500 3000 [m3/h]

50 Hz 60 Hz
Contacts

45
Drawings Guard grille Wall ring Terminal box Capacitor Electr. connections
p. 46 f. p. 362 f. p. 372 f. p. 381 p. 382 f. p. 416 f.
AC axial fans
S series, Ø 330, drawings of directions of air flow "V" and "A"

Type
Without attachments c
A4D 330-AP10 -01 "V" 6.0
- 0 + Depth of screw
A4D 330-AP10 -02 "A" -8.0
max. 5 mm
c ±3 87 A4E 330-AP18 -01 "V" 6.0
A4E 330-AP18 -02 "A" -8.0
M4
Brass lead tips A6E 330-AP02 -01 "V" 6.0
M4
2 A6E 330-AP02 -02 "A" -8.0

4x90˚
Ø27

Ø330 ±2
Ø92

27

6
85
450 ±20

83 ±2 58 ±0,2

 "V"
"A" 

Type
With full round nozzle
W4D 330-CP10 -30 "V"
80 W4D 330-CP10 -31 "A"
11 W4E 330-CP18 -30 "V"
W4E 330-CP18 -31 "A"
W6E 330-CP02 -30 "V"
404 W6E 330-CP02 -31 "A"
Ø369
Ø440

15˚
9
˚
60
6x

30
 "V"
"A" 

Type
With guard grille for full nozzle
S4D 330-BP10 -30 "V"
30 S4D 330-BP10 -31 "A"
4,5 6,5 S4E 330-BP18 -30 "V"
S4E 330-BP18 -31 "A"
S6E 330-BP02 -30 "V"
S6E 330-BP02 -31 "A"
410

 "V"
"A" 

46
information
General
AC axial fans
Type
With guard grille for short nozzle u
S4D 330-AP10 -30 "V" 43.0
80 S4D 330-AP10 -31 "A" 29.0
4,5 6,5
S4E 330-AP18 -30 "V" 43.0

AC axial
S series
S4E 330-AP18 -31 "A" 29.0

30 S6E 330-AP02 -30 "V" 43.0


S6E 330-AP02 -31 "A" 29.0
354,5

410

AC axial
K series
u

AC axial
A series
33

 "V"
"A" 

EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

47
AC axial fans
S series, Ø 350

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: A C "B", B "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

3~ 230/400 50 3340 1420 135 0.73/0.42 — 64 120 -25 to +60


*4D 350 (1) M4D 068-EC A
3~ 230/400 60 3815 1620 185 0.64/0.37 — 68 145 -25 to +45 3.6 C1)/C2)
1~ 230 50 3250 1365 132 0.58 5.0 /400 64 90 -25 to +60
*4E 350 M4E 068-EC B
1~ 230 60 3640 1530 180 0.80 5.0 /400 67 65 -25 to +50 3.6 A1)
1~ 230 50 2110 905 60 0.27 2.5 /400 55 40 -25 to +60
*6E 350 M6E 068-DF C
1~ 230 60 2420 1040 85 0.38 2.5 /400 58 45 -25 to +55 3.6 A1)
subject to alterations (1) 230 VAC ∆ / 400 VAC Y

n P1 I
Curves [rpm] [W] [A]

A 1 1400 150 0.75/0.43


[Pa]

[in H O]
2

A 2 1380 173 0.75/0.43

160
0,6

120
0,4

80 2

A
0,2

40
1

0 500 1000 1500 2000 [CFM]

1000 2000 3000 [m3/h]

50 Hz 60 Hz

48
Drawings
p. 50 f.
information
General
AC axial fans
– Motor protection: A Without TOP, B C TOP wired internally
– Cable exit: A Lateral, B C axial
– Protection class: I
– Product conforming to standards: EN 60335-1, B C also CE

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"
Without With full With guard grille With guard grille In-line duct fan
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A4D 350-AR06 -01 W4D 350-CR06 -30 S4D 350-BR06 -30 S4D 350-AR06 -30 W4D 350-IR06 -01
"A" A4D 350-AR06 -02 W4D 350-CR06 -31 S4D 350-BR06 -31 S4D 350-AR06 -31 —
"V" A4E 350-AR06 -01 W4E 350-CR06 -30 S4E 350-BR06 -30 S4E 350-AR06 -30 W4E 350-IR06 -01
"A" A4E 350-AR06 -02 W4E 350-CR06 -31 S4E 350-BR06 -31 S4E 350-AR06 -31 —
"V" A6E 350-AR08 -01 W6E 350-CR08 -30 S6E 350-BR08 -30 S6E 350-AR08 -30 —
"A" A6E 350-AR08 -02 W6E 350-CR08 -31 S6E 350-BR08 -31 S6E 350-AR08 -31 —

EC axial
S series
Q-motor
n P1 I
Curves [rpm] [W] [A]

B 1 1335 142 0.63


[Pa]

[in H O]
2

ESM
B 2 1260 166 0.74
C 1 880 63 0.28
0,4

100
C 2 825 68 0.30
EC-SYSTEMS

80 2
0,3

60
0,2

B
Accessories

40 2
C

1
0,1

20 1
Technology

0 500 1000 1500 2000 [CFM]

1000 2000 3000 [m3/h]

50 Hz 60 Hz
Contacts

49
Guard grille Streamer Wall ring Terminal box Capacitor Electr. connections
p. 362 f. p. 371 p. 372 f. p. 381 p. 382 f. p. 416 f.
AC axial fans
S series, Ø 350, drawings of directions of air flow "V" and "A"

Type
Without attachments a c
A4D 350-AR06 -01 "V" 102.0 10.0
- 0 + Depth of screw
A4D 350-AR06 -02 "A" 102.0 -10.0
max. 5 mm
c ±3 92 ±3 A4E 350-AR06 -01 "V" 102.0 10.0
A4E 350-AR06 -02 "A" 102.0 -10.0
M4
Brass lead tips A6E 350-AR08 -01 "V" 83.0 5.0
M4
2 A6E 350-AR08 -02 "A" 83.0 -12.0
Ø352 ±2

4x90˚
Ø27

Ø92

27

6
85
600 ±20

a ±2 58 ±0,2

 "V"
"A" 

Type
With full round nozzle
W4D 350-CR06 -30 "V"
80 W4D 350-CR06 -31 "A"
12 W4E 350-CR06 -30 "V"
W4E 350-CR06 -31 "A"
W6E 350-CR08 -30 "V"
442 W6E 350-CR08 -31 "A"
Ø390
Ø460

15˚
9
˚
60
6x

30
 "V"
"A" 

Type
With guard grille for full nozzle
S4D 350-BR06 -30 "V"
30 S4D 350-BR06 -31 "A"
4,5 6,5 S4E 350-BR06 -30 "V"
S4E 350-BR06 -31 "A"
S6E 350-BR08 -30 "V"
S6E 350-BR08 -31 "A"
422

 "V"
"A" 

50
information
General
AC axial fans
Type
With guard grille for short nozzle u v
S4D 350-AR06 -30 "V" 52.0 52.0
80 S4D 350-AR06 -31 "A" 32.0 52.0
4,5 6,5
S4E 350-AR06 -30 "V" 52.0 52.0

AC axial
S series
S4E 350-AR06 -31 "A" 32.0 52.0

30 S6E 350-AR08 -30 "V" 47.0 33.0


S6E 350-AR08 -31 "A" 30.0 33.0

422
374

AC axial
K series
u

AC axial
A series
v

 "V"
"A" 

Type
In-line duct fan

EC axial fans
W4D 350-IR06 -01 "V"
W4E 350-IR06 -01 "V"

EC axial
S series
Q-motor
 "V"

ESM
EC-SYSTEMS
Accessories
Technology
Contacts

51
AC axial fans
S series, Ø 400

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: A B "B", C "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

3~ 230/400 50 4000 1450 135 0.76/0.44 — 68 150 -25 to +40


*4D 400 (1)(2) M4D 074-EI A
3~ 230/400 60 4610 1690 185 0.68/0.39 — 72 120 -25 to +40 4.2 C1)/C2)
1~ 230 50 4235 1430 160 0.73 6.0 /400 69 150 -25 to +40
*4E 400 M4E 074-EI B
1~ 230 60 4950 1700 240 1.06 6.0 /400 73 75 -25 to +40 4.2 A1)
1~ 230 50 3290 940 120 0.55 3.0 /450 59 50 -25 to +40
*6E 400 M6E 074-DF C
1~ 230 60 3780 1080 170 0.75 3.0 /400 62 40 -25 to +60 4.0 A1)
subject to alterations (1) 400 VAC ∆/Y for two speed steps available on request (2) 230 VAC ∆ / 400 VAC Y

n P1 I
Curves [rpm] [W] [A]

A 1 1440 152 0.82/0.47


[Pa]

[in H O]
2

A 2 1415 195 0.86/0.50


160
0,6

120
0,4

80

A
0,2

40

0 500 1000 1500 2000 2500 [CFM]

1000 2000 3000 4000 [m3/h]

50 Hz 60 Hz

52
Drawings
p. 54 f.
information
General
AC axial fans
– Motor protection: A Without TOP, B C TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, B C also CE
– Approvals: CCC

AC axial
S series
– Options: Terminal box

AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"
Without With full With guard grille With guard grille In-line duct fan
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A4D 400-AP12 -01 W4D 400-CP12 -30 S4D 400-BP12 -30 S4D 400-AP12 -03 W4D 400-IP12 -01
"A" A4D 400-AP12 -02 W4D 400-CP12 -31 S4D 400-BP12 -31 S4D 400-AP12 -04 —
"V" A4E 400-AP02 -01 W4E 400-CP02 -30 S4E 400-BP02 -30 S4E 400-AP02 -03 W4E 400-IP02 -01
"A" A4E 400-AP02 -02 W4E 400-CP02 -31 S4E 400-BP02 -31 S4E 400-AP02 -04 —
"V" A6E 400-AP10 -01 W6E 400-CP10 -30 S6E 400-BP10 -30 S6E 400-AP10 -30 —
"A" A6E 400-AP10 -02 W6E 400-CP10 -31 S6E 400-BP10 -31 S6E 400-AP10 -31 —

EC axial
S series
Q-motor
n P1 I
Curves [rpm] [W] [A]

B 1 1430 172 0.78


[Pa]

[in H O]
2

ESM
B 2 1395 210 0.93
160
C 1 935 126 0.57
0,6

C 2 895 140 0.62


EC-SYSTEMS

120
0,4

80
Accessories
0,2

2
B
40
C
Technology

1
1

0 500 1000 1500 2000 2500 [CFM]

1000 2000 3000 4000 [m3/h]

50 Hz 60 Hz
Contacts

53
Guard grille Streamer Wall ring Terminal box Capacitor Electr. connections
p. 362 ff. p. 371 p. 372 f. p. 381 p. 382 f. p. 416 f.
AC axial fans
S series, Ø 400, drawings of directions of air flow "V" and "A"

Type
Without attachments a c p
A4D 400-AP12 -01 "V" 117.0 26.0 68.0
- 0 + Depth of screw
A4D 400-AP12 -02 "A" 117.0 22.0 68.0
max. 10 mm
c ±3 p ±3 A4E 400-AP02 -01 "V" 117.0 26.0 68.0
A4E 400-AP02 -02 "A" 117.0 22.0 68.0
M4
Brass lead tips A6E 400-AP10 -01 "V" 104.0 -5.0 90.0
M6
5 A6E 400-AP10 -02 "A" 104.0 14.0 88.0

4x90˚
Ø392 ±2
Ø75

Ø102

37

6
85
600 ±20

a ±2 90 ±0,2

 "V"
"A" 

Type
With full round nozzle
W4D 400-CP12 -30 "V"
96 W4D 400-CP12 -31 "A"
12 W4E 400-CP02 -30 "V"
W4E 400-CP02 -31 "A"
W6E 400-CP10 -30 "V"
504 W6E 400-CP10 -31 "A"
Ø419
Ø528

15˚
9
˚
60
6x

30
 "V"
"A" 

Type
With guard grille for full nozzle
S4D 400-BP12 -30 "V"
30 S4D 400-BP12 -31 "A"
5 9 S4E 400-BP02 -30 "V"
S4E 400-BP02 -31 "A"
S6E 400-BP10 -30 "V"
S6E 400-BP10 -31 "A"
502

 "V"
"A" 

54
information
General
AC axial fans
Type
With guard grille for short nozzle f k u v
S4D 400-AP12 -03 "V" 420.0 10.0 24.0 47.0
80 S4D 400-AP12 -04 "A" 420.0 10.0 20.0 47.0
5 9
S4E 400-AP02 -03 "V" 420.0 10.0 24.0 47.0

AC axial
S series
S4E 400-AP02 -04 "A" 420.0 10.0 20.0 47.0

k S6E 400-AP10 -30 "V" 414.0 30.0 35.0 54.0


S6E 400-AP10 -31 "A" 414.0 30.0 52.0 54.0

470
f

AC axial
K series
u

AC axial
A series
v

 "V"
"A" 

Type
In-line duct fan

EC axial fans
W4D 400-IP12 -01 "V"
W4E 400-IP02 -01 "V"

EC axial
S series
Q-motor
 "V"

ESM
EC-SYSTEMS
Accessories
Technology
Contacts

55
AC axial fans
S series, Ø 420

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Plastic, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Speed/rpm (1)

Max. current

attachments
Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm W A µF/VDB Pa °C kg p. 416 f.

A 3~ 400 ∆ 50 1360 260 0.52 — 95 -40 to +60


B 3~ 400 Y 50 1060 185 0.31 — 60 -40 to +60 5.8 F1b)/F2b)
*4D 420 M4D 094-EA
C 3~ 400 ∆ 60 1490 385 0.65 — 110 -40 to +60
D 3~ 400 Y 60 970 220 0.37 — 47 -40 to +60 5.8 F1b)/F2b)
1~ 230 50 1360 280 1.25 7.0 /400 95 -40 to +60
*4E 420 M4E 094-EA E
1~ 230 60 1520 385 1.68 7.0 /400 100 -40 to +60 5.8 A2b)
subject to alterations (1) Nominal data in operating point with maximum load

n P1 I LpA
Curves [rpm] [W] [A] [dB(A)]

A 1 1380 225 0.47 67


[Pa]

[in H O]
2

A 2 1360 260 0.52 65

120 B 1 1120 170 0.29 61


B 2 1060 185 0.31 58
0,4

100
2
C

80
0,3

60 2

B
0,2

40 1
D
1
0,1

20

0 1000 2000 3000 [CFM]

1000 2000 3000 4000 5000 [m3/h]

50 Hz 60 Hz

56
information
General
AC axial fans
– Motor protection: A - D Design with thermal overload protector, E TOP wired internally
– Cable exit: Lateral via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A4D 420-AU02 -01 W4D 420-CU02 -30 S4D 420-BU02 -30 S4D 420-AU02 -03
"A" A4D 420-AU02 -02 W4D 420-CU02 -31 S4D 420-BU02 -31 S4D 420-AU02 -04

"V" A4E 420-AU03 -01 W4E 420-CU03 -30 S4E 420-BU03 -30 S4E 420-AU03 -03
"A" A4E 420-AU03 -02 W4E 420-CU03 -31 S4E 420-BU03 -31 S4E 420-AU03 -04

EC axial
S series
Q-motor
n P1 I LpA
Curves [rpm] [W] [A] [dB(A)]

E 1 1390 247 1.13 67


[Pa]

[in H O]
2

ESM
E 2 1360 280 1.25 65

120
0,4

100
EC-SYSTEMS

80
0,3

60
Accessories
0,2

40 1
0,1

20
Technology

0 1000 2000 3000 [CFM]

1000 2000 3000 4000 5000 [m3/h]

50 Hz 60 Hz
Contacts

57
Drawings Guard grille Wall ring Capacitor Electr. connections
p. 58 f. p. 362 f. p. 372 f. p. 382 f. p. 416 f.
AC axial fans
S series, Ø 420, drawings of directions of air flow "V" and "A"

Type
Without attachments b c1 h
A4D 420-AU02 -01 "V" Ø 89 2.0 33.5
Depth of screw
A4D 420-AU02 -02 "A" Ø 89 16.0 33.5
max. 10 mm
A4E 420-AU03 -01 "V" 99x99 2.0 59.5
A4E 420-AU03 -02 "A" 99x99 16.0 59.5

Cable gland

 "V"
"A" 

Type
With full round nozzle
W4D 420-CU02 -30 "V"
W4D 420-CU02 -31 "A"
W4E 420-CU03 -30 "V"
W4E 420-CU03 -31 "A"

 "V"
"A" 

Type
With guard grille for full nozzle c2
S4D 420-BU02 -30 "V" 77.5
S4D 420-BU02 -31 "A" 91.5
S4E 420-BU03 -30 "V" 77.5
S4E 420-BU03 -31 "A" 91.5

 "V"
"A" 

58
 "V"
"A" 
With guard grille for short nozzle

S4E
S4E
S4D
S4D
Type

420-AU03
420-AU03
420-AU02
420-AU02

-04
-03
-04
-03

"V"
"V"

"A"
"A"
c3

61.5
47.5
61.5
47.5

59
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans 6-pole
S series, Ø 420 / 450

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

1~ 230 50 3940 940 145 0.67 4.0 /450 60 90 -25 to +50


*6E 420 M6E 074-EI A
1~ 230 60 4570 1090 205 0.90 4.0 /450 63 80 -25 to +45 4.4 A1)
1~ 230 50 4725 940 165 0.80 4.0 /450 63 70 -25 to +40
*6E 450 M6E 074-GA B
1~ 230 60 5450 1070 225 0.98 4.0 /450 67 45 -25 to +40 5.0 A1)
subject to alterations

n P1 I
Curves [rpm] [W] [A]

A 1 930 155 0.71


[Pa]

[in H O]
2

A
A 2 890 176 0.80
160
0,6

120
0,4

80

2
0,2

40
1

0 1000 2000 3000 [CFM]

1000 2000 3000 4000 5000 [m3/h]

50 Hz 60 Hz

60
information
General
AC axial fans
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC

AC axial
S series
– Options: Terminal box

AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A6E 420-AP02 -01 W6E 420-CP02 -30 S6E 420-BP02 -30 S6E 420-AP02 -30
"A" A6E 420-AP02 -02 W6E 420-CP02 -31 S6E 420-BP02 -31 S6E 420-AP02 -31
"V" A6E 450-AP02 -01 W6E 450-CP02 -01 S6E 450-BP02 -01 S6E 450-AP02 -01
"A" A6E 450-AP02 -02 W6E 450-CP02 -02 S6E 450-BP02 -02 S6E 450-AP02 -02

EC axial
S series
Q-motor
n P1 I
Curves [rpm] [W] [A]

B 1 930 171 0.82


[Pa]

[in H O]

B
2

ESM
B 2 870 200 0.94

120
0,4

100
EC-SYSTEMS

80
0,3

2
60
Accessories
0,2

40
0,1

20
Technology

0 1000 2000 3000 [CFM]

1000 2000 3000 4000 5000 6000 [m3/h]

50 Hz 60 Hz
Contacts

61
Drawings Guard grille Wall ring Terminal box Capacitor Electr. connections
p. 62 f. p. 362 ff. p. 372 f. p. 381 p. 382 f. p. 416 f.
AC axial fans
S series, Ø 420 / 450, drawings of directions of air flow "V" and "A"

Type
Without attachments a b c p
A6E 420-AP02 -01 "V" 117.0 418.0 2.0 89.0
- 0 + Depth of screw
A6E 420-AP02 -02 "A" 117.0 418.0 21.0 89.0
max. 10 mm
c ±3 p ±3 A6E 450-AP02 -01 "V" 129.0 446.0 10.0 92.0
A6E 450-AP02 -02 "A" 129.0 446.0 25.0 92.0
M4
Brass lead tips M6
5

4x90˚
Ø75

Ø102
Øb ±2

37

6
85
600 ±20

a ±2 90 ±0,2

 "V"
"A" 

Type
With full round nozzle s t u v w x
W6E 420-CP02 -30 "V" 9.0 520.0 96.0 12.0 447.0 544.0
u W6E 420-CP02 -31 "A" 9.0 520.0 96.0 12.0 447.0 544.0
v W6E 450-CP02 -01 "V" 11.0 578.0 100.0 14.0 465.0 607.0
W6E 450-CP02 -02 "A" 11.0 578.0 100.0 14.0 465.0 607.0

t
Øw
Øx

15˚
s
˚
60
6x

30
 "V"
"A" 

Type
With guard grille for full nozzle r
S6E 420-BP02 -30 "V" 502.0
30 S6E 420-BP02 -31 "A" 502.0
5 9 S6E 450-BP02 -01 "V" 522.0
S6E 450-BP02 -02 "A" 522.0
r

 "V"
"A" 

62
information
General
AC axial fans
Type
With guard grille for short nozzle f r u v
S6E 420-AP02 -30 "V" 452.0 502.0 41.0 67.0
80 S6E 420-AP02 -31 "A" 452.0 502.0 60.0 67.0
5 9
S6E 450-AP02 -01 "V" 476.0 522.0 52.0 79.0

AC axial
S series
S6E 450-AP02 -02 "A" 476.0 522.0 67.0 79.0

30

r
f

AC axial
K series
u

AC axial
A series
v

 "V"
"A" 

EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

63
AC axial fans
S series, Ø 450

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Plastic, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Speed/rpm (1)

Max. current

attachments
Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm W A µF/VDB Pa °C kg p. 416 f.

A 3~ 400 ∆ 50 1250 340 0.61 — 120 -40 to +60


B 3~ 400 Y 50 875 200 0.33 — 60 -40 to +60 6.0 F1b)/F2b)
*4D 450 M4D 094-EA
C 3~ 400 ∆ 60 1360 415 0.70 — 85 -40 to +50
D 3~ 400 Y 60 860 205 0.35 — 35 -40 to +50 6.0 F1b)/F2b)
1~ 230 50 1300 350 1.55 8.0 /400 120 -40 to +55
*4E 450 M4E 094-EA E
1~ 230 60 1490 425 1.87 8.0 /400 50 -40 to +45 6.0 A2b)
subject to alterations (1) Nominal data in operating point with maximum load

n P1 I LpA
Curves [rpm] [W] [A] [dB(A)]

A 1 1300 285 0.54 67


[Pa]

[in H O]
2

A 2 1250 340 0.61 64

120 2 B 1 985 180 0.30 59


B 2 875 200 0.33 54
A
0,4

100

80
C
0,3

60 2 1
B
0,2

40

1
D
0,1

20

0 1000 2000 2000 [CFM]

1000 2000 3000 4000 5000 6000 [m3/h]

50 Hz 60 Hz

64
information
General
AC axial fans
– Motor protection: A - D Design with thermal overload protector, E TOP wired internally
– Cable exit: Lateral via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A4D 450-AU01 -01 W4D 450-CU01 -01 S4D 450-BU01 -01 S4D 450-AU01 -01
"A" A4D 450-AU01 -02 W4D 450-CU01 -02 S4D 450-BU01 -02 S4D 450-AU01 -02

"V" A4E 450-AU03 -01 W4E 450-CU03 -01 S4E 450-BU03 -01 S4E 450-AU03 -01
"A" A4E 450-AU03 -02 W4E 450-CU03 -02 S4E 450-BU03 -02 S4E 450-AU03 -02

EC axial
S series
Q-motor
n P1 I LpA
Curves [rpm] [W] [A] [dB(A)]

E 1 1350 310 1.35 68


[Pa]

[in H O]
2

ESM
E 2 1300 350 1.55 65

120 2
0,4

100
EC-SYSTEMS

80
0,3

60 1
Accessories
0,2

40 E
0,1

20
Technology

0 1000 2000 3000 [CFM]

1000 2000 3000 4000 5000 6000 [m3/h]

50 Hz 60 Hz
Contacts

65
Drawings Guard grille Wall ring Capacitor Electr. connections
p. 66 f. p. 362 f. p. 372 f. p. 382 f. p. 416 f.
AC axial fans
S series, Ø 450, drawings of directions of air flow "V" and "A"

Type
Without attachments b c1 h
A4D 450-AU01 -01 "V" Ø 89 6.0 33.5
Depth of screw
A4D 450-AU01 -02 "A" Ø 89 20.0 33.5
max. 10 mm
A4E 450-AU03 -01 "V" 99x99 6.0 59.5
A4E 450-AU03 -02 "A" 99x99 20.0 59.5

Cable gland

 "V"
"A" 

Type
With full round nozzle
W4D 450-CU01 -01 "V"
W4D 450-CU01 -02 "A"
W4E 450-CU03 -01 "V"
W4E 450-CU03 -02 "A"

 "V"
"A" 

Type
With guard grille for full nozzle c2
S4D 450-BU01 -01 "V" 60.5
S4D 450-BU01 -02 "A" 74.5
S4E 450-BU03 -01 "V" 60.5
S4E 450-BU03 -02 "A" 74.5

 "V"
"A" 

66
 "V"
"A" 
With guard grille for short nozzle

S4E
S4E
S4D
S4D
Type

450-AU03
450-AU03
450-AU01
450-AU01

-02
-01
-02
-01

"V"
"V"

"A"
"A"
c3

33.5
19.5
33.5
19.5

67
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
S series, Ø 450

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Speed/rpm (1)

Max. current

attachments
Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm W A µF/VDB Pa °C kg p. 416 f.

A 3~ 400 ∆ 50 1330 585 1.10 — 200 -40 to +70


B 3~ 400 Y 50 1000 390 0.67 — 110 -40 to +70 7.9 F1b)/F2b)
*4D 450 M4D 094-HA
C 3~ 400 ∆ 60 1540 660 1.16 — 110 -40 to +50
D 3~ 400 Y 60 1060 400 0.70 — 55 -40 to +50 7.9 F1b)/F2b)
1~ 230 50 1350 480 2.10 10.0 /400 125 -40 to +65
*4E 450 M4E 094-HA E
1~ 230 60 1490 665 2.90 10.0 /400 115 -40 to +50 7.9 A2b)
subject to alterations (1) Nominal data in operating point with maximum load

n P1 I LpA
Curves [rpm] [W] [A] [dB(A)]

A 1 1400 392 0.89 72


[Pa]

[in H O]
2

A 2 1370 476 0.98 70


B 1 1170 303 0.53 68
0,8

200
B 2 1030 375 0.63 66

160
0,6

120 A
0,4

2
B
C
80
0,2

40 D
1 1

0 1000 2000 3000 4000 [CFM]

2000 4000 6000 [m3/h]

50 Hz 60 Hz

68
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Lateral via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"
Without With full With guard grille With guard grille In-line duct fan
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A4D 450-BA14 -01 W4D 450-GA14 -01 S4D 450-HA14 -01 S4D 450-GA14 -01 —
"A" A4D 450-BA14 -02 W4D 450-GA14 -02 S4D 450-HA14 -02 S4D 450-GA14 -02 —

"V" A4E 450-BA09 -01 W4E 450-GA09 -01 S4E 450-HA09 -01 S4E 450-GA09 -01 —
"A" A4E 450-BA09 -02 W4E 450-GA09 -02 S4E 450-HA09 -02 S4E 450-GA09 -02 —

EC axial
S series
Q-motor
n P1 I LpA
Curves [rpm] [W] [A] [dB(A)]

E 1 1380 413 2.01 72


[Pa]

[in H O]
2

ESM
E 2 1360 460 2.20 70
0,8

200

EC-SYSTEMS

160
0,6

120
0,4

2
Accessories

80 E
0,2

40 1
Technology

0 1000 2000 3000 4000 [CFM]

2000 4000 6000 [m3/h]

50 Hz 60 Hz
Contacts

69
Drawings Guard grille Streamer Wall ring Capacitor Electr. connections
p. 72 f. p. 362 ff. p. 371 p. 372 f. p. 382 f. p. 416 f.
AC axial fans
S series, Ø 450

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

in-line duct fan


Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor

Mass of
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm W A µF/VDB Pa °C kg p. 416 f.

A 3~ 400 ∆ 50 1350 490 1.00 — 115 -40 to +95


*4D 450 M4D 110-EF 0° B 3~ 400 Y 50 1075 340 0.58 — 75 -40 to +95 14.5 F1b)/F2b)
1~ 230 50 1330 500 2.20 10.0 /400 100 -40 to +80
*4E 450 M4E 110-EF 0° C 14.5 A2b)
subject to alterations (1) Nominal data in operating point with maximum load

n P1 I LwA
Curves [rpm] [W] [A] [dB(A)]

A 1 1370 450 0.97 76


[Pa]

[in H O]
2

A 2 1360 470 0.99 77


A 3 1350 490 1.00 79
120
3 B 1 1120 320 0.56 71
A B 2 1090 330 0.57 73
0,4

100 B 3 1075 340 0.58 75

2
80
0,3

3
B

60
2
0,2

40
1
0,1

20

0 1000 2000 3000 4000 [CFM]

1000 2000 3000 4000 5000 6000 7000 [m3/h]

-10° -5° 0°

70
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"
Without With full With guard grille With guard grille In-line duct fan
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" — — — — W4D 450-IG01 -01
"A" — — — — —
"V" — — — — W4E 450-IG01 -01
"A" — — — — —

EC axial
S series
Q-motor
n P1 I LwA
Curves [rpm] [W] [A] [dB(A)]

C 1 1360 460 2.00 76


[Pa]

[in H O]
2

ESM
C 2 1340 480 2.10 77
C 3 1330 500 2.20 78
100
0,4

C
EC-SYSTEMS

2
80
0,3

60
0,2

Accessories

40
0,1

20
Technology

0 1000 2000 3000 4000 [CFM]

1000 2000 3000 4000 5000 6000 7000 [m3/h]


-10° -5° 0°
Contacts

71
Drawings Capacitor Electr. connections
p. 73 p. 382 f. p. 416 f.
AC axial fans
S series, Ø 450, drawings of directions of air flow "V" and "A"

Type
Without attachments b c h
A4D 450-BA14 -01 "V" Ø 89 35.0 33.5
A4D 450-BA14 -02 "A" Ø 89 36.7 33.5
A4E 450-BA09 -01 "V" 99x99 35.0 59.5
A4E 450-BA09 -02 "A" 99x99 36.7 59.5

Depth of screw
Cable gland max. 12 mm
 "V"
"A" 

Type
With full round nozzle
W4D 450-GA14 -01 "V"
W4D 450-GA14 -02 "A"
W4E 450-GA09 -01 "V"
W4E 450-GA09 -02 "A"

 "V"
"A" 

Type
With guard grille for full nozzle
S4D 450-HA14 -01 "V"
S4D 450-HA14 -02 "A"
S4E 450-HA09 -01 "V"
S4E 450-HA09 -02 "A"

 "V"
"A" 

72
information
General
AC axial fans
Type
With guard grille for short nozzle u
S4D 450-GA14 -01 "V" 64.0
S4D 450-GA14 -02 "A" 65.7
S4E 450-GA09 -01 "V" 64.0

AC axial
S series
S4E 450-GA09 -02 "A" 65.7

AC axial
K series
AC axial
A series
 "V"
"A" 

Type
In-line duct fan

EC axial fans
W4D 450-IG01 -01 "V"
W4E 450-IG01 -01 "V"

EC axial
S series
Q-motor
 "V"

ESM
EC-SYSTEMS
Accessories
Technology
Contacts

73
AC axial fans
S series, Ø 500

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A µF/VDB Pa °C p. 416 f.

A 3~ 400 ∆ 50 1310 0.58 1.10 — 155 -40 to +85


*4D 500 M4D 110-EF -10° B 3~ 400 Y 50 1010 0.38 0.65 — 95 -40 to +85 F1b)/F2b)
C 3~ 400 ∆ 50 1325 0.82 1.59 — 160 -40 to +80
*4D 500 M4D 110-GF 0° D 3~ 400 Y 50 1035 0.55 0.95 — 100 -40 to +80 F1b)/F2b)
E 3~ 400 ∆ 50 1360 0.69 1.43 — 160 -40 to +90
*4D 500 M4D 110-GF -5° F 3~ 400 Y 50 1110 0.49 0.86 — 105 -40 to +90 F1b)/F2b)
subject to alterations (1) Nominal data in operating point 3 with maximum load

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

1355 0.46 0.97 76


[Pa]

[in H O]

A 1
2

A 2 1340 0.50 1.01 78


160 3 3 A 3 1310 0.58 1.10 80
3
0,6

B 1 1110 0.33 0.56 72


140 B 2 1070 0.34 0.60 73
B 3 1010 0.38 0.65 74
2
120
C 1 1355 0.70 1.39 77
A 2
3 C 2 1345 0.75 1.44 78
0,4

100 3 C 3 1325 0.82 1.59 80


2
3
D 1 1100 0.50 0.84 73
80 2 D 2 1070 0.52 0.87 72
B 2 1
E

1 C D 3 1035 0.55 0.95 74


2
60
F 1 E 1 1390 0.57 1.23 76
0,2

1
1 E 2 1380 0.62 1.29 77
40 1 E 3 1360 0.69 1.43 80
F 1 1180 0.43 0.72 73
D
20 F 2 1150 0.46 0.77 73
F 3 1110 0.49 0.86 76
0 1250 2500 3750 5000 [CFM]

2000 4000 6000 8000 [m3/h]

-10˚ -5˚ 0˚

74
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A"  "A"   "V"
Without With full With guard grille With guard grille With guard grille With guard grille In-line duct fan
attachments square nozzle for full nozzle for short nozzle for full nozzle for short nozzle

EC axial fans
"V" A4D 500-AI01 -01 W4D 500-GI01 -01 S4D 500-CI01 -01 S4D 500-AI01 -01 — — —
"A" A4D 500-AI01 -02 W4D 500-DI01 -02 — — S4D 500-BI01 -02 S4D 500-AI01 -02 —
"V" A4D 500-AD03 -01 W4D 500-GD03 -01 S4D 500-CD03 -01 S4D 500-AD03 -01 — — W4D 500-ID03 -01
"A" A4D 500-AD03 -02 W4D 500-DD03 -02 — — S4D 500-BD03 -02 S4D 500-AD03 -02 —
"V" A4D 500-AE03 -01 W4D 500-GE03 -01 S4D 500-CE03 -01 S4D 500-AE03 -01 — — —
"A" A4D 500-AE03 -02 W4D 500-DE03 -02 — — S4D 500-BE03 -02 S4D 500-AE03 -02 —

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

75
Drawings Speed setting Motor protection Electr. connections
p. 82 ff. p. 384 f. p. 386 ff. p. 416 f.
AC axial fans
S series, Ø 500

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A µF/VDB Pa °C p. 416 f.

A 3~ 400 ∆ 50 920 0.32 0.75 — 75 -40 to +75


*6D 500 M6D 110-EF 0° B 3~ 400 Y 50 765 0.23 0.40 — 50 -40 to +75 F1b)/F2b)
C 3~ 400 ∆ 50 945 0.29 0.74 — 80 -40 to +80
*6D 500 M6D 110-EF -5° D 3~ 400 Y 50 790 0.20 0.36 — 60 -40 to +80 F1b)/F2b)
E 3~ 400 ∆ 50 950 0.23 0.69 — 65 -40 to +80
*6D 500 M6D 110-EF -10° F1b)/F2b)
G 3~ 400 ∆ 50 700 0.21 0.61 — 45 -40 to +70
*8D 500 M8D 110-EF 0° H 3~ 400 Y 50 615 0.12 0.25 — 34 -40 to +70 F1b)/F2b)
subject to alterations (1) Nominal data in operating point 3 with maximum load

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

A 1 935 0.29 0.75 70


[Pa]

[in H O]
2

A 2 930 0.30 0.76 70


A 3 920 0.32 0.75 71
3
80
B 1 800 0.20 0.36 67
3
B 2 785 0.21 0.37 66
0,3

3
B 3 765 0.23 0.40 67

3
C 1 950 0.24 0.71 69
2
60
E
C 2 940 0.25 0.72 69
2
3 C 3 945 0.29 0.74 72
2
0,2

A
D 1 845 0.17 0.31 66
22 D 2 830 0.18 0.33 66
C
40
1 D 3 790 0.20 0.36 68
1
E 1 960 0.20 0.68 68
11
1 E 2 955 0.21 0.68 70
0,1

20
B E 3 950 0.23 0.69 71

0 1000 2000 3000 [CFM]

1000 2000 3000 4000 5000 6000 [m3/h]

-10˚ -5˚ 0˚

76
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A"  "A"   "V"
Without With full With guard grille With guard grille With guard grille With guard grille In-line duct fan
attachments square nozzle for full nozzle for short nozzle for full nozzle for short nozzle

EC axial fans
"V" A6D 500-AG03 -01 W6D 500-GG03 -01 S6D 500-CG03 -01 S6D 500-AG03 -01 — — —
"A" A6D 500-AG03 -02 W6D 500-DG03 -02 — — S6D 500-BG03 -02 S6D 500-AG03 -02 —
"V" A6D 500-AH03 -01 W6D 500-GH03 -01 S6D 500-CH03 -01 S6D 500-AH03 -01 — — —
"A" A6D 500-AH03 -02 W6D 500-DH03 -02 — — S6D 500-BH03 -02 S6D 500-AH03 -02 —
"V" A6D 500-AI03 -01 W6D 500-GI03 -01 S6D 500-CI03 -01 S6D 500-AI03 -01 — — —
"A" A6D 500-AI03 -02 W6D 500-DI03 -02 — — S6D 500-BI03 -02 S6D 500-AI03 -02 —
"V" A8D 500-AG01 -01 W8D 500-GG01 -01 S8D 500-CG01 -01 S8D 500-AG01 -01 — — —

EC axial
S series
"A" A8D 500-AG01 -02 W8D 500-DG01 -02 — — S8D 500-BG01 -02 S8D 500-AG01 -02 —

Q-motor
n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

G 1 710 0.19 0.64 64


[Pa]

[in H O]
2

ESM
G 2 710 0.20 0.63 62
G 3 700 0.21 0.61 65
0,20

50
H 1 635 0.11 0.23 61
3
H 2 630 0.12 0.24 60
615 0.12 0.25 61
EC-SYSTEMS
G H 3

40
0,15

3
2

30
2
0,10

Accessories

H
1
20
1
0,05

10
Technology

0 500 1000 1500 2000 2500 [CFM]

1000 2000 3000 4000 [m3/h]

-10˚ -5˚ 0˚
Contacts

77
Drawings Speed setting Motor protection Electr. connections
p. 82 ff. p. 384 f. p. 386 ff. p. 416 f.
AC axial fans
S series, Ø 500

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A µF/VDB Pa °C p. 416 f.

*4E 500 M4E 110-EF -10° A 1~ 230 50 1300 0.53 2.31 10.0 /450 115 -40 to +75 A2b)

*4E 500 M4E 110-GF 0° B 1~ 230 50 1270 0.76 3.33 14.0 /400 130 -40 to +60 A2b)

*4E 500 M4E 110-GF -5° C 1~ 230 50 1330 0.71 3.10 14.0 /450 160 -40 to +70 A2b)
subject to alterations (1) Nominal data in operating point 3 with maximum load

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

1345 0.47 2.06 76


[Pa]

[in H O]

A 1
2

3
A 2 1320 0.51 2.21 77
160 A 3 1300 0.53 2.31 78
0,6

B 1 1305 0.71 3.13 77


140
3 B 2 1285 0.75 3.28 77
B 3 1270 0.76 3.33 78
120 2
3 2 C 1 1375 0.59 2.59 76
C 2 1355 0.64 2.80 77
0,4

100 C 3 1330 0.71 3.10 80


B
2

80 1
1

60 A

1
0,2

40

20

0 1250 2500 3750 5000 [CFM]

2000 4000 6000 8000 [m3/h]

-10˚ -5˚ 0˚

78
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A"  "A"   "V"
Without With full With guard grille With guard grille With guard grille With guard grille In-line duct fan
attachments square nozzle for full nozzle for short nozzle for full nozzle for short nozzle

EC axial fans
"V" A4E 500-AI01 -01 W4E 500-GI01 -01 S4E 500-CI01 -01 S4E 500-AI01 -01 — — —
"A" A4E 500-AI01 -02 W4E 500-DI01 -02 — — S4E 500-BI01 -02 S4E 500-AI01 -02 —
"V" A4E 500-AD03 -01 W4E 500-GD03 -01 S4E 500-CD03 -01 S4E 500-AD03 -01 — — W4E 500-ID03 -01
"A" A4E 500-AD03 -02 W4E 500-DD03 -02 — — S4E 500-BD03 -02 S4E 500-AD03 -02 —
"V" A4E 500-AE03 -01 W4E 500-GE03 -01 S4E 500-CE03 -01 S4E 500-AE03 -01 — — —
"A" A4E 500-AE03 -02 W4E 500-DE03 -02 — — S4E 500-BE03 -02 S4E 500-AE03 -02 —

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

79
Drawings Capacitor Speed setting Motor protection Electr. connections
p. 82 ff. p. 382 f. p. 384 f. p. 386 ff. p. 416 f.
AC axial fans
S series, Ø 500

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A µF/VDB Pa °C p. 416 f.

*6E 500 M6E 110-EF 0° A 1~ 230 50 890 0.30 1.32 8.0 /400 70 -40 to +80 A2b)

*6E 500 M6E 110-EF -5° B 1~ 230 50 910 0.27 1.19 8.0 /450 80 -40 to +85 A2b)

*6E 500 M6E 110-EF -10° C 1~ 230 50 930 0.25 1.10 8.0 /450 85 -40 to +85 A2b)

*8E 500 M8E 110-EF 0° D 1~ 230 50 690 0.19 1.11 4.0 /450 40 -40 to +80 A2b)
subject to alterations (1) Nominal data in operating point 3 with maximum load

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

A 1 910 0.28 1.20 71


[Pa]

[in H O]
2

A 2 900 0.29 1.25 69


3 A 3 890 0.30 1.32 70
3 B

80
B 1 935 0.24 1.04 69
B 2 925 0.25 1.09 69
0,3

C 3 B 3 910 0.27 1.19 72


2
C 1 945 0.23 0.99 69
60 C 2 940 0.24 1.04 71
2 2
C 3 930 0.25 1.10 74
0,2

A
1

40
1
1
0,1

20

0 1000 2000 3000 [CFM]

1000 2000 3000 4000 5000 6000 [m3/h]

-10˚ -5˚ 0˚

80
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A"  "A"   "V"
Without With full With guard grille With guard grille With guard grille With guard grille In-line duct fan
attachments square nozzle for full nozzle for short nozzle for full nozzle for short nozzle

EC axial fans
"V" A6E 500-AG03 -01 W6E 500-GG03 -01 S6E 500-CG03 -01 S6E 500-AG03 -01 — — W6E 500-IG03 -01
"A" A6E 500-AG03 -02 W6E 500-DG03 -02 — — S6E 500-BG03 -02 S6E 500-AG03 -02 —
"V" A6E 500-AH03 -01 W6E 500-GH03 -01 S6E 500-CH03 -01 S6E 500-AH03 -01 — — —
"A" A6E 500-AH03 -02 W6E 500-DH03 -02 — — S6E 500-BH03 -02 S6E 500-AH03 -02 —
"V" A6E 500-AI03 -01 W6E 500-GI03 -01 S6E 500-CI03 -01 S6E 500-AI03 -01 — — —
"A" A6E 500-AI03 -02 W6E 500-DI03 -02 — — S6E 500-BI03 -02 S6E 500-AI03 -02 —
"V" A8E 500-AG01 -01 W8E 500-GG01 -01 S8E 500-CG01 -01 S8E 500-AG01 -01 — — —

EC axial
S series
"A" A8E 500-AG01 -02 W8E 500-DG01 -02 — — S8E 500-BG01 -02 S8E 500-AG01 -02 —

Q-motor
n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

D 1 695 0.18 1.09 64


[Pa]

[in H O]
2

ESM
D 2 695 0.19 1.10 63
D 3 690 0.19 1.11 63
0,20

50

EC-SYSTEMS
3
40
0,15

2
30
0,10

Accessories

1
20
0,05

10
Technology

0 500 1000 1500 2000 2500 [CFM]

1000 2000 3000 4000 [m3/h]

-10˚ -5˚ 0˚
Contacts

81
Drawings Capacitor Speed setting Motor protection Electr. connections
p. 82 ff. p. 382 f. p. 384 f. p. 386 ff. p. 416 f.
AC axial fans
S series, Ø 500, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] c d g
A4D 500-AI01 -01 8.8 92.0 78.0 188.5
A4D 500-AD03 -01 11.0 104.0 101.0 208.5
A4D 500-AE03 -01 11.0 98.0 89.0 208.5
A6D 500-AG03 -01 8.8 104.0 101.0 188.5
A6D 500-AH03 -01 8.8 98.0 89.0 188.5
A6D 500-AI03 -01 8.8 92.0 78.0 188.5
A8D 500-AG01 -01 8.8 104.0 101.0 188.5
A4E 500-AI01 -01 8.8 92.0 78.0 188.5
A4E 500-AD03 -01 11.0 104.0 101.0 208.5
A4E 500-AE03 -01 11.0 98.0 89.0 208.5
A6E 500-AG03 -01 8.8 104.0 101.0 188.5
A6E 500-AH03 -01 8.8 98.0 89.0 188.5
A6E 500-AI03 -01 8.8 92.0 78.0 188.5
Depth of screw A8E 500-AG01 -01 8.8 104.0 101.0 188.5
max. 12 mm
Cable gland

 "V"

Type Mass
With full square nozzle [kg]
W4D 500-GI01 -01 18.6
W4D 500-GD03 -01 21.0
W4D 500-GE03 -01 21.0
W6D 500-GG03 -01 18.6
W6D 500-GH03 -01 18.6
W6D 500-GI03 -01 18.6
W8D 500-GG01 -01 18.6
W4E 500-GI01 -01 18.6
W4E 500-GD03 -01 21.0
W4E 500-GE03 -01 21.0
W6E 500-GG03 -01 18.6
W6E 500-GH03 -01 18.6
W6E 500-GI03 -01 18.6
W8E 500-GG01 -01 18.6

 "V"

Type Mass
With guard grille for full nozzle [kg] r s t
S4D 500-CI01 -01 12.6 63.5 91.0 123.0
6,5 S4D 500-CD03 -01 14.8 65.5 103.0 143.0
View X S4D 500-CE03 -01 14.8 65.5 97.0 143.0
S6D 500-CG03 -01 12.6 65.5 103.0 123.0
S6D 500-CH03 -01 12.6 65.5 97.0 123.0
S6D 500-CI03 -01 12.6 63.5 97.0 123.0
S8D 500-CG01 -01 12.6 63.5 103.0 123.0
S4E 500-CI01 -01 12.6 63.5 91.0 123.0
S4E 500-CD03 -01 14.8 65.5 103.0 143.0
S4E 500-CE03 -01 14.8 65.5 97.0 143.0
S6E 500-CG03 -01 12.6 63.5 103.0 123.0
S6E 500-CH03 -01 12.6 63.5 97.0 123.0
S6E 500-CI03 -01 12.6 63.5 97.0 123.0
S8E 500-CG01 -01 12.6 63.5 103.0 123.0

 "V"

82
information
General
AC axial fans
Type Mass
With guard grille for short nozzle [kg] u v
S4D 500-AI01 -01 13.3 32.0 64.0
S4D 500-AD03 -01 15.5 44.0 84.0
S4D 500-AE03 -01 15.5 38.0 84.0

AC axial
S series
S6D 500-AG03 -01 13.3 44.0 64.0
S6D 500-AH03 -01 13.3 38.0 64.0
S6D 500-AI03 -01 13.3 32.0 64.0
S8D 500-AG01 -01 13.3 44.0 64.0
S4E 500-AI01 -01 13.3 32.0 64.0
S4E 500-AD03 -01 15.5 44.0 84.0

AC axial
K series
S4E 500-AE03 -01 15.5 38.0 84.0
S6E 500-AG03 -01 13.3 44.0 64.0
S6E 500-AH03 -01 13.3 38.0 64.0
S6E 500-AI03 -01 13.3 32.0 64.0
S8E 500-AG01 -01 13.3 44.0 64.0

AC axial
A series
 "V"

Type Mass
In-line duct fan

EC axial fans
[kg]
W4D 500-ID03 -01 16.8
W4E 500-ID03 -01 16.8
W6E 500-IG03 -01 14.8

EC axial
S series
Q-motor
 "V"

ESM
EC-SYSTEMS
Accessories
Technology
Contacts

83
AC axial fans
S series, Ø 500, drawings for direction of air flow "A"

Type Mass
Without attachments [kg] c d g
A4D 500-AI01 -02 8.8 95.0 78.0 188.5
A4D 500-AD03 -02 11.0 131.0 101.0 208.5
A4D 500-AE03 -02 11.0 126.0 89.0 208.5
A6D 500-AG03 -02 8.8 131.0 101.0 188.5
A6D 500-AH03 -02 8.8 126.0 89.0 188.5
A6D 500-AI03 -02 8.8 120.0 78.0 188.5
A8D 500-AG01 -02 8.8 131.0 101.0 188.5
A4E 500-AI01 -02 8.8 120.0 78.0 188.5
A4E 500-AD03 -02 11.0 131.0 101.0 208.5
A4E 500-AE03 -02 11.0 126.0 89.0 208.5
A6E 500-AG03 -02 8.8 131.0 101.0 188.5
A6E 500-AH03 -02 8.8 126.0 89.0 188.5
A6E 500-AI03 -02 8.8 120.0 78.0 188.5
Depth of screw A8E 500-AG01 -02 8.8 131.0 101.0 188.5
max. 12 mm
Cable gland

"A" 

Type Mass
With full square nozzle [kg]
W4D 500-DI01 -02 18.8
W4D 500-DD03 -02 21.0
W4D 500-DE03 -02 21.0
W6D 500-DG03 -02 18.8
W6D 500-DH03 -02 18.8
W6D 500-DI03 -02 18.8
W8D 500-DG01 -02 18.8
W4E 500-DI01 -02 18.8
W4E 500-DD03 -02 21.0
W4E 500-DE03 -02 21.0
W6E 500-DG03 -02 18.8
W6E 500-DH03 -02 18.8
W6E 500-DI03 -02 18.8
W8E 500-DG01 -02 18.8

"A" 

Type Mass
With guard grille for full nozzle [kg] s t
S4D 500-BI01 -02 12.6 95.0 99.0
S4D 500-BD03 -02 14.8 119.0 106.0
S4D 500-BE03 -02 14.8 119.0 101.0
S6D 500-BG03 -02 12.6 99.0 106.0
S6D 500-BH03 -02 12.6 99.0 101.0
S6D 500-BI03 -02 12.6 95.0 99.0
S8D 500-BG01 -02 12.6 106.0 99.0
S4E 500-BI01 -02 12.6 95.0 99.0
S4E 500-BD03 -02 14.8 119.0 106.0
S4E 500-BE03 -02 14.8 119.0 101.0
S6E 500-BG03 -02 12.6 106.0 99.0
S6E 500-BH03 -02 12.6 101.0 99.0
S6E 500-BI03 -02 12.6 95.0 99.0
S8E 500-BG01 -02 12.6 106.0 99.0

"A" 

84
information
General
AC axial fans
Type Mass
With guard grille for short nozzle [kg] u v
S4D 500-AI01 -02 12.3 45.0 49.0
S4D 500-AD03 -02 14.5 56.0 69.0
S4D 500-AE03 -02 14.5 51.0 69.0

AC axial
S series
S6D 500-AG03 -02 12.3 56.0 49.0
S6D 500-AH03 -02 12.3 51.0 49.0
S6D 500-AI03 -02 12.3 45.0 49.0
S8D 500-AG01 -02 12.3 56.0 49.0
S4E 500-AI01 -02 12.3 45.0 49.0
S4E 500-AD03 -02 14.5 56.0 69.0

AC axial
K series
S4E 500-AE03 -02 14.5 51.0 69.0
S6E 500-AG03 -02 12.3 56.0 49.0
S6E 500-AH03 -02 12.3 51.0 49.0
S6E 500-AI03 -02 12.3 45.0 49.0
S8E 500-AG01 -02 12.3 56.0 49.0

AC axial
A series
"A" 

EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

85
AC axial fans
S series, Ø 560

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A µF/VDB Pa °C p. 416 f.

A 3~ 400 ∆ 50 1305 0.93 1.78 — 195 -40 to +65


*4D 560 M4D 110-GF -10° B 3~ 400 Y 50 995 0.60 1.05 — 110 -40 to +65 F1b)/F2b)
C 3~ 400 ∆ 50 1355 1.17 2.53 — 170 -40 to +60
*4D 560 M4D 110-IA -5° D 3~ 400 Y 50 1080 0.80 1.45 — 113 -40 to +60 F1b)/F2b)
E 3~ 400 ∆ 50 860 0.50 0.95 — 80 -40 to +55
*6D 560 M6D 110-EF 0° F 3~ 400 Y 50 615 0.30 0.52 — 40 -40 to +55 F1b)/F2b)
G 3~ 400 ∆ 50 890 0.43 0.90 — 90 -40 to +70
*6D 560 M6D 110-EF -5° H 3~ 400 Y 50 660 0.28 0.48 — 50 -40 to +70 F1b)/F2b)
subject to alterations (1) Nominal data in operating point 3 with maximum load

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

1350 0.76 1.50 79


[Pa]

0,8 [in H O]

A 1
2

A 2 1330 0.84 1.60 79


200 3
A 3 1305 0.93 1.78 80
3 B 1 1085 0.53 0.89 76
A

B 2 1040 0.56 0.95 75


160
B 3 995 0.60 1.05 75
0,6

2 C 1 1385 0.99 2.33 80


C
C 2 1370 1.07 2.45 80
120
3 3 2
C 3 1355 1.17 2.53 81
D 1 1155 0.72 1.28 77
0,4

B D 2 1125 0.76 1.35 76


2 D
80 2
1 D 3 1080 0.80 1.45 77

1
0,2

1
40

0 1500 3000 4500 6000 [CFM]

2000 4000 6000 8000 10000 [m3/h]

-10˚ -5˚ 0˚

86
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A"  "A"   "V"
Without With full With guard grille With guard grille With guard grille With guard grille In-line duct fan
attachments square nozzle for full nozzle for short nozzle for full nozzle for short nozzle

EC axial fans
"V" A4D 560-AF03 -01 W4D 560-GF03 -01 S4D 560-CF03 -01 S4D 560-AF03 -01 — — —
"A" A4D 560-AF03 -02 W4D 560-DF03 -02 — — S4D 560-BF03 -02 S4D 560-AF03 -02 —
"V" A4D 560-AB01 -01 W4D 560-GB01 -01 S4D 560-CB01 -01 S4D 560-AB01 -01 — — W4D 560-IB01 -01
"A" A4D 560-AB01 -02 W4D 560-DB01 -02 — — S4D 560-BB01 -02 S4D 560-AB01 -02 —
"V" A6D 560-AG03 -01 W6D 560-GG03 -01 S6D 560-CG03 -01 S6D 560-AG03 -01 — — W6D 560-IG03 -01
"A" A6D 560-AG03 -02 W6D 560-DG03 -02 — — S6D 560-BG03 -02 S6D 560-AG03 -02 —
"V" A6D 560-AH03 -01 W6D 560-GH03 -01 S6D 560-CH03 -01 S6D 560-AH03 -01 — — —

EC axial
S series
"A" A6D 560-AH03 -02 W6D 560-DH03 -02 — — S6D 560-BH03 -02 S6D 560-AH03 -02 —

Q-motor
n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

E 1 885 0.43 0.87 73


[Pa]

[in H O]
2

ESM
E 2 875 0.46 0.89 73
E 3 860 0.50 0.95 74
0,4

100
F 1 670 0.28 0.49 66
3
G F 2 645 0.29 0.50 66
615 0.30 0.52 66
EC-SYSTEMS
F 3

80 3
G 1 915 0.36 0.78 71
0,3

G 2 900 0.39 0.81 71


2
G 3 890 0.43 0.90 71
60 2
H 1 720 0.25 0.40 66
H
3
E H 2 695 0.26 0.42 65
0,2

Accessories

H 3 660 0.28 0.48 64


3
40 2
1
1
F 2
0,1

1
20 1
Technology

0 1250 2500 3750 5000 [CFM]

2000 4000 6000 8000 [m3/h]

-10˚ -5˚ 0˚
Contacts

87
Drawings Speed setting Motor protection Electr. connections
p. 90 ff. p. 384 f. p. 386 ff. p. 416 f.
AC axial fans
S series, Ø 560

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A µF/VDB Pa °C p. 416 f.

*4E 560 M4E 110-IA -5° A 1~ 230 50 1300 1.05 4.60 20.0 /400 110 -40 to +60 A2b)

*6E 560 M6E 110-GF -5° B 1~ 230 50 910 0.43 1.95 10.0 /450 90 -40 to +70 A2b)
subject to alterations (1) Nominal data in operating point 3 with maximum load

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

1330 0.97 4.21 79


[Pa]

[in H O]

A 1
2

A 2 1310 1.01 4.39 79


0,5

A 3 1300 1.05 4.60 79


120
3

100
0,4

2
80
0,3

60

1
0,2

40
0,1

20

0 1500 3000 4500 6000 [CFM]

2000 4000 6000 8000 10000 [m3/h]

-10˚ -5˚ 0˚

88
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A"  "A"   "V"
Without With full With guard grille With guard grille With guard grille With guard grille In-line duct fan
attachments square nozzle for full nozzle for short nozzle for full nozzle for short nozzle

EC axial fans
"V" A4E 560-AB01 -01 W4E 560-GB01 -01 S4E 560-CB01 -01 S4E 560-AB01 -01 — — W4E 560-IB01 -01
"A" A4E 560-AB01 -02 W4E 560-DB01 -02 — — S4E 560-BB01 -02 S4E 560-AB01 -02 —
"V" A6E 560-AE01 -01 W6E 560-GE01 -01 S6E 560-CE01 -01 S6E 560-AE01 -01 — — —
"A" A6E 560-AE01 -02 W6E 560-DE01 -02 — — S6E 560-BE01 -02 S6E 560-AE01 -02 —

EC axial
S series
Q-motor
n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

B 1 935 0.37 1.65 73


[Pa]

[in H O]
2

ESM
B 2 925 0.39 1.80 72
B 3 910 0.43 1.95 72
0,4

100 3

EC-SYSTEMS

80 B
0,3

2
60
0,2

Accessories

40

1
0,1

20
Technology

0 1250 2500 3750 5000 [CFM]

2000 4000 6000 8000 [m3/h]

-10˚ -5˚ 0˚
Contacts

89
Drawings Capacitor Speed setting Motor protection Electr. connections
p. 90 ff. p. 382 f. p. 384 f. p. 386 ff. p. 416 f.
AC axial fans
S series, Ø 560, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] c d g
A4D 560-AF03 -01 11.5 95.0 96.0 208.5
A4D 560-AB01 -01 13.5 105.0 113.0 223.5
A6D 560-AG03 -01 9.0 114.0 129.0 188.5
A6D 560-AH03 -01 9.0 105.0 113.0 188.5
A4E 560-AB01 -01 13.5 105.0 113.0 223.5
A6E 560-AE01 -01 11.5 105.0 113.0 208.5

Depth of screw
max. 12 mm
Cable gland

 "V"

Type Mass
With full square nozzle [kg]
W4D 560-GF03 -01 20.0
W4D 560-GB01 -01 21.5
W6D 560-GG03 -01 18.0
W6D 560-GH03 -01 18.0
W4E 560-GB01 -01 21.5
W6E 560-GE01 -01 20.0

 "V"

Type Mass
With guard grille for full nozzle [kg] s t
S4D 560-CF03 -01 14.0 95.0 144.0
6,5 S4D 560-CB01 -01 15.5 105.0 159.0
View X S6D 560-CG03 -01 12.0 114.0 124.0
S6D 560-CH03 -01 12.0 105.0 124.0
S4E 560-CB01 -01 15.5 105.0 159.0
S6E 560-CE01 -01 14.0 105.0 144.0

 "V"

90
information
General
AC axial fans
Type Mass
With guard grille for short nozzle [kg] u v
S4D 560-AF03 -01 15.5 35.0 84.0
S4D 560-AB01 -01 17.0 45.0 99.0
S6D 560-AG03 -01 13.5 54.0 64.0

AC axial
S series
S6D 560-AH03 -01 13.5 45.0 64.0
S4E 560-AB01 -01 17.0 45.0 99.0
S6E 560-AE01 -01 15.5 45.0 84.0

AC axial
K series
AC axial
A series
 "V"

Type Mass
In-line duct fan

EC axial fans
[kg]
W4D 560-IB01 -01 20.9
W6D 560-IG03 -01 16.4
W4E 560-IB01 -01 20.9

EC axial
S series
Q-motor
 "V"

ESM
EC-SYSTEMS
Accessories
Technology
Contacts

91
AC axial fans
S series, Ø 560, drawings for direction of air flow "A"

Type Mass
Without attachments [kg] c d g
A4D 560-AF03 -02 11.5 134.0 96.0 208.5
A4D 560-AB01 -02 13.5 142.0 113.0 223.5
A6D 560-AG03 -02 9.0 149.0 129.0 188.5
A6D 560-AH03 -02 9.0 142.0 113.0 188.5
A4E 560-AB01 -02 13.5 142.0 113.0 223.5
A6E 560-AE01 -02 11.5 142.0 113.0 208.5

Depth of screw
max. 12 mm
Cable gland

"A" 

Type Mass
With full square nozzle [kg]
W4D 560-DF03 -02 20.3
W4D 560-DB01 -02 21.8
W6D 560-DG03 -02 18.3
W6D 560-DH03 -02 18.3
W4E 560-DB01 -02 21.8
W6E 560-DE01 -02 20.3

"A" 

Type Mass
With guard grille for full nozzle [kg] s t
S4D 560-BF03 -02 14.0 134.0 124.0
S4D 560-BB01 -02 15.5 149.0 132.0
S6D 560-BG03 -02 12.0 114.0 139.0
S6D 560-BH03 -02 12.0 114.0 132.0
S4E 560-BB01 -02 15.5 149.0 132.0
S6E 560-BE01 -02 14.0 134.0 132.0

"A" 

92
information
General
AC axial fans
Type Mass
With guard grille for short nozzle [kg] u v
S4D 560-AF03 -02 14.5 59.0 69.0
S4D 560-AB01 -02 16.0 67.0 84.0
S6D 560-AG03 -02 12.5 74.0 49.0

AC axial
S series
S6D 560-AH03 -02 12.5 67.0 49.0
S4E 560-AB01 -02 16.0 67.0 84.0
S6E 560-AE01 -02 14.5 67.0 69.0

AC axial
K series
AC axial
A series
"A" 

EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

93
AC axial fans
S series, Ø 630

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A µF/VDB Pa °C p. 416 f.

A 3~ 400 ∆ 50 1330 1.94 3.40 — 200 -40 to +65


*4D 630 M4D 138-HF -5° B 3~ 400 Y 50 1040 1.29 2.20 — 120 -40 to +65 F1b)/F2b)
C 3~ 400 ∆ 50 1360 1.62 3.02 — 200 -40 to +65
*4D 630 M4D 138-HF -10° D 3~ 400 Y 50 1120 1.12 1.87 — 130 -40 to +65 F1b)/F2b)
E 3~ 400 ∆ 50 1340 2.53 4.95 — 240 -40 to +60
*4D 630 M4D 138-LA 0° F 3~ 400 Y 50 1045 1.64 2.88 — 145 -40 to +60 F1b)/F2b)
subject to alterations (1) Nominal data in operating point 3 with maximum load

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

1350 1.66 3.03 79


[Pa]

[in H O]

A 1
2

220
A 2 1335 1.78 3.17 79
3
3
A 3 1330 1.94 3.40 81
0,8

200 B 1 1095 1.16 1.95 73


A
180
B 2 1065 1.22 2.04 73
B 3 1040 1.29 2.20 75
160
C 2 C 1 1390 1.29 2.58 80
0,6

140
C 2 1380 1.41 2.70 80
3
3
2 C 3 1360 1.62 3.02 83
120 B
D 1 1190 0.98 1.65 76
D D 2 1160 1.04 1.75 75
0,4

100 2 1
2 D 3 1120 1.12 1.87 78
80 1

1
60 1
0,2

40

20

0 2500 5000 7500 10000 [CFM]

4000 8000 12000 16000 [m3/h]

-10˚ -5˚ 0˚

94
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A"  "A"   "V"
Without With full With guard grille With guard grille With guard grille With guard grille In-line duct fan
attachments square nozzle for full nozzle for short nozzle for full nozzle for short nozzle

EC axial fans
"V" A4D 630-AN01 -01 W4D 630-GN01 -01 S4D 630-CN01 -01 S4D 630-AN01 -01 — — W4D 630-IN01 -01
"A" A4D 630-AN01 -02 W4D 630-DN01 -02 — — S4D 630-BN01 -02 — —
"V" A4D 630-AO01 -01 W4D 630-GO01 -01 S4D 630-CO01 -01 S4D 630-AO01 -01 — — —
"A" A4D 630-AO01 -02 W4D 630-DO01 -02 — — S4D 630-BO01 -02 — —
"V" A4D 630-AJ01 -01 W4D 630-GJ01 -01 S4D 630-CJ01 -01 S4D 630-AJ01 -01 — — —
"A" A4D 630-AJ01 -02 W4D 630-DJ01 -02 — — S4D 630-BJ01 -02 — —

EC axial
S series
Q-motor
n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

1355 2.28 4.43 78


[Pa]

1,0 [in H O]

E 1
2

ESM
E 2 1345 2.40 4.63 79
3
E 3 1340 2.53 4.95 81
240
E F 1 1085 1.56 2.73 72
F 2 1065 1.61 2.82 73
0,8

200 1045 1.64 2.88 75


EC-SYSTEMS
F 3
2

160 3
0,6

1
120 2
Accessories
0,4

80 1
0,2

40
Technology

0 4000 8000 12000 [CFM]

4000 8000 12000 16000 20000 [m3/h]

-10˚ -5˚ 0˚
Contacts

95
Drawings Speed setting Motor protection Electr. connections
p. 96 ff. p. 384 f. p. 386 ff. p. 416 f.
AC axial fans
S series, Ø 630, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] c d g
A4D 630-AN01 -01 20.0 147.0 133.0 251.0
A4D 630-AO01 -01 20.0 142.0 118.0 251.0
A4D 630-AJ01 -01 24.0 152.0 147.0 276.0

Depth of screw
max. 18 mm
Cable gland

 "V"

Type Mass
With full square nozzle [kg]
W4D 630-GN01 -01 37.0
W4D 630-GO01 -01 37.0
W4D 630-GJ01 -01 41.0

 "V"

Type Mass
With guard grille for full nozzle [kg] s t
S4D 630-CN01 -01 28.0 146.0 175.0
68
S4D 630-CO01 -01 28.0 141.0 175.0
7,5

15,5
26
10

View X S4D 630-CJ01 -01 32.0 76.0 151.0

92

 "V"

96
information
General
AC axial fans
Type Mass
With guard grille for short nozzle [kg] u v
S4D 630-AN01 -01 29.5 80.0 109.0
S4D 630-AO01 -01 29.5 75.0 109.0
S4D 630-AJ01 -01 33.5 85.0 134.0

AC axial
S series
AC axial
K series
AC axial
A series
 "V"

Type Mass
In-line duct fan

EC axial fans
[kg]
W4D 630-IN01 -01 27.9

EC axial
S series
Q-motor
 "V"

ESM
EC-SYSTEMS
Accessories
Technology
Contacts

97
AC axial fans
S series, Ø 630, drawings for direction of air flow "A"

Type Mass
Without attachments [kg] c d g
A4D 630-AN01 -02 20.0 175.0 133.0 251.0
A4D 630-AO01 -02 20.0 165.0 118.0 251.0
A4D 630-AJ01 -02 24.0 185.0 147.0 276.0

Depth of screw
Cable gland max. 18 mm

"A" 

Type Mass
With full square nozzle [kg]
W4D 630-DN01 -02 38.0
W4D 630-DO01 -02 38.0
W4D 630-DJ01 -02 42.0

"A" 

Type Mass
With guard grille for full nozzle [kg] s t
S4D 630-BN01 -02 29.0 126.0 127.0
S4D 630-BO01 -02 29.0 116.0 127.0
S4D 630-BJ01 -02 33.0 136.0 152.0

"A" 

98
99
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
S series, Ø 630

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A µF/VDB Pa °C p. 416 f.

A 3~ 400 ∆ 50 890 0.61 1.26 — 105 -40 to +60


*6D 630 M6D 110-GF -5° B 3~ 400 Y 50 680 0.40 0.72 — 60 -40 to +60 F1b)/F2b)
C 3~ 400 ∆ 50 910 0.53 1.15 — 110 -40 to +70
*6D 630 M6D 110-GF -10° D 3~ 400 Y 50 725 0.38 0.67 — 70 -40 to +70 F1b)/F2b)
E 3~ 400 ∆ 50 885 0.83 1.68 — 120 -40 to +55
*6D 630 M6D 110-IA 0° F 3~ 400 Y 50 655 0.53 0.95 — 68 -40 to +55 F1b)/F2b)
G 3~ 400 ∆ 50 640 0.38 0.91 — 62 -40 to +65
*8D 630 M8D 110-GF 0° H 3~ 400 Y 50 440 0.21 0.42 — 30 -40 to +65 F1b)/F2b)
I 3~ 400 ∆ 50 660 0.33 0.85 — 65 -40 to +75
*8D 630 M8D 110-GF -5° J 3~ 400 Y 50 500 0.20 0.40 — 35 -40 to +75 F1b)/F2b)
subject to alterations (1) Nominal data in operating point 3 with maximum load

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

925 0.48 1.12 75


[Pa]

0,5 [in H O]

A 1
2

A 2 915 0.52 1.16 75


A 3 890 0.61 1.26 76
120
3 3
B 1 770 0.35 0.63 72
3 B 2 745 0.37 0.66 71
100 E
0,4

B 3 680 0.40 0.72 71


C 1 940 0.41 1.04 75
A
3
C 2 930 0.45 1.06 75
80 D C
2
C 3 910 0.53 1.15 78
0,3

3
3 F
2
D 1 825 0.29 0.52 73
60 D 2 805 0.31 0.55 72
2 D 3 725 0.38 0.67 74
0,2

2
2 1 E 1 915 0.67 1.48 75
40 2
1
E 2 905 0.72 1.54 76
B E 3 885 0.83 1.68 76
11
0,1

1
1 F 1 735 0.47 0.83 71
20
F 2 710 0.49 0.86 71
F 3 655 0.53 0.95 70

0 1500 3000 4500 6000 [CFM]

2000 4000 6000 8000 10000 [m3/h]

-10˚ -5˚ 0˚

100
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A"  "A"   "V"
Without With full With guard grille With guard grille With guard grille With guard grille In-line duct fan
attachments square nozzle for full nozzle for short nozzle for full nozzle for short nozzle

EC axial fans
"V" A6D 630-AE01 -01 W6D 630-GE01 -01 S6D 630-CE01 -01 S6D 630-AE01 -01 — — —
"A" A6D 630-AE01 -02 W6D 630-DE01 -02 — — S6D 630-BE01 -02 S6D 630-AE01 -02 —
"V" A6D 630-AF01 -01 W6D 630-GF01 -01 S6D 630-CF01 -01 S6D 630-AF01 -01 — — —
"A" A6D 630-AF01 -02 W6D 630-DF01 -02 — — S6D 630-BF01 -02 S6D 630-AF01 -02 —
"V" A6D 630-AA01 -01 W6D 630-GA01 -01 S6D 630-CA01 -01 S6D 630-AA01 -01 — — W6D 630-IA01 -01
"A" A6D 630-AA01 -02 W6D 630-DA01 -02 — — S6D 630-BA01 -02 S6D 630-AA01 -02 —
"V" A8D 630-AD01 -01 W8D 630-GD01 -01 S8D 630-CD01 -01 S8D 630-AD01 -01 — — —

EC axial
S series
"A" A8D 630-AD01 -02 W8D 630-DD01 -02 — — S8D 630-BD01 -02 S8D 630-AD01 -02 —
"V" A8D 630-AE01 -01 W8D 630-GE01 -01 S8D 630-CE01 -01 S8D 630-AE01 -01 — — —
"A" A8D 630-AE01 -02 W8D 630-DE01 -02 — — S8D 630-BE01 -02 S8D 630-AE01 -02 —

Q-motor
n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

G 1 660 0.33 0.84 69


[Pa]

[in H O]
2

ESM
G 2 655 0.35 0.85 69
70 G 3 640 0.38 0.91 69
3
3 H 1 495 0.19 0.40 63
60 G H 2 475 0.20 0.41 62
440 0.21 0.42 61
EC-SYSTEMS
H 3
I
I 1 680 0.28 0.81 69
0,2

50
2 I 2 675 0.30 0.82 70
2 I 3 660 0.33 0.85 71
40
3 J 1 555 0.17 0.36 71
J
J 2 535 0.18 0.38 71
Accessories

3
30 J 3 500 0.20 0.40 71
2
H 1
0,1

2
1
20

10
Technology

0 1250 2500 3750 5000 [CFM]

2000 4000 6000 8000 [m3/h]

-10˚ -5˚ 0˚
Contacts

101
Drawings Speed setting Motor protection Electr. connections
p. 104 ff. p. 384 f. p. 386 ff. p. 416 f.
AC axial fans
S series, Ø 630

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A µF/VDB Pa °C p. 416 f.

*6E 630 M6E 110-GF -5° A 1~ 230 50 880 0.61 2.65 14.0 /450 100 -40 to +60 A2b)

*6E 630 M6E 110-GF -10° B 1~ 230 50 905 0.49 2.15 12.0 /450 100 -40 to +70 A2b)

*6E 630 M6E 110-IA 0° C 1~ 230 50 860 0.76 3.35 16.0 /450 100 -40 to +50 A2b)

*8E 630 M8E 110-GF -5° D 1~ 230 50 655 0.35 1.79 7.0 /450 60 -40 to +60 A2b)
subject to alterations (1) Nominal data in operating point 3 with maximum load

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

905 0.55 2.41 75


[Pa]

[in H O]

A 1
2

A 2 895 0.58 2.51 75


3
3 3 A 3 880 0.61 2.65 76
100
0,4

B 1 925 0.43 1.89 75


2

C
B 2 920 0.45 1.99 76
2 B 3 905 0.49 2.15 78
B
80
C 1 890 0.71 3.11 76
0,3

2 C 2 875 0.73 3.23 76


1
C 3 860 0.76 3.35 76
60 A

1
0,2

1
40
0,1

20

0 1500 3000 4500 6000 [CFM]

2000 4000 6000 8000 10000 [m3/h]

-10˚ -5˚ 0˚

102
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A"  "A"   "V"
Without With full With guard grille With guard grille With guard grille With guard grille In-line duct fan
attachments square nozzle for full nozzle for short nozzle for full nozzle for short nozzle

EC axial fans
"V" A6E 630-AE01 -01 W6E 630-GE01 -01 S6E 630-CE01 -01 S6E 630-AE01 -01 — — —
"A" A6E 630-AE01 -02 W6E 630-DE01 -02 — — S6E 630-BE01 -02 S6E 630-AE01 -02 —
"V" A6E 630-AF01 -01 W6E 630-GF01 -01 S6E 630-CF01 -01 S6E 630-AF01 -01 — — —
"A" A6E 630-AF01 -02 W6E 630-DF01 -02 — — S6E 630-BF01 -02 S6E 630-AF01 -02 —
"V" A6E 630-AA03 -01 W6E 630-GA03 -01 S6E 630-CA03 -01 S6E 630-AA03 -01 — — W6E 630-IA03 -01
"A" A6E 630-AA03 -02 W6E 630-DA03 -02 — — S6E 630-BA03 -02 S6E 630-AA03 -02 —
"V" A8E 630-AE01 -01 W8E 630-GE01 -01 S8E 630-CE01 -01 S8E 630-AE01 -01 — — —

EC axial
S series
"A" A8E 630-AE01 -02 W8E 630-DE01 -02 — — S8E 630-BE01 -02 S8E 630-AE01 -02 —

Q-motor
n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

D 1 685 0.30 1.61 69


[Pa]

[in H O]
2

ESM
D 2 675 0.32 1.68 69
70 D 3 655 0.35 1.79 69

3
60
EC-SYSTEMS

D
0,2

50

2
40
Accessories

30
0,1

1
20

10
Technology

0 1250 2500 3750 5000 [CFM]

2000 4000 6000 8000 [m3/h]

-10˚ -5˚ 0˚
Contacts

103
Drawings Capacitor Speed setting Motor protection Electr. connections
p. 104 ff. p. 382 f. p. 384 f. p. 386 ff. p. 416 f.
AC axial fans
S series, Ø 630, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] c d g
A6D 630-AE01 -01 12.5 108.0 116.0 208.5
A6D 630-AF01 -01 12.5 96.0 96.0 208.5
A6D 630-AA01 -01 14.0 120.0 135.0 223.5
A8D 630-AD01 -01 12.5 120.0 135.0 208.5
A8D 630-AE01 -01 12.5 108.0 116.0 208.5
A6E 630-AE01 -01 12.5 108.0 116.0 208.5
A6E 630-AF01 -01 12.5 96.0 96.0 208.5
A6E 630-AA03 -01 14.0 120.0 135.0 223.5
A8E 630-AE01 -01 12.5 108.0 116.0 208.5

Depth of screw
max. 12 mm
Cable gland

 "V"

Type Mass
With full square nozzle [kg]
W6D 630-GE01 -01 20.5
W6D 630-GF01 -01 20.5
W6D 630-GA01 -01 23.0
W8D 630-GD01 -01 20.5
W8D 630-GE01 -01 20.5
W6E 630-GE01 -01 20.5
W6E 630-GF01 -01 20.5
W6E 630-GA03 -01 23.0
W8E 630-GE01 -01 20.5

 "V"

Type Mass
With guard grille for full nozzle [kg] s t
S6D 630-CE01 -01 14.5 97.5 111.5
6,5 S6D 630-CF01 -01 14.5 85.5 111.5
View X S6D 630-CA01 -01 17.0 109.5 126.5
S8D 630-CD01 -01 14.5 109.5 133.5
S8D 630-CE01 -01 14.5 97.5 111.5
S6E 630-CE01 -01 14.5 97.5 133.5
S6E 630-CF01 -01 14.5 85.5 111.5
S6E 630-CA03 -01 17.0 109.5 148.5
S8E 630-CE01 -01 14.5 97.5 133.5

 "V"

104
information
General
AC axial fans
Type Mass
With guard grille for short nozzle [kg] u v
S6D 630-AE01 -01 16.0 23.0 59.0
S6D 630-AF01 -01 16.0 11.0 59.0
S6D 630-AA01 -01 18.5 35.0 74.0

AC axial
S series
S8D 630-AD01 -01 16.0 35.0 59.0
S8D 630-AE01 -01 16.0 23.0 59.0
S6E 630-AE01 -01 16.0 23.0 59.0
S6E 630-AF01 -01 16.0 11.0 59.0
S6E 630-AA03 -01 18.5 35.0 74.0
S8E 630-AE01 -01 16.0 23.0 59.0

AC axial
K series
AC axial
A series
 "V"

Type Mass
In-line duct fan

EC axial fans
[kg]
W6D 630-IA01 -01 21.4
W6E 630-IA03 -01 21.4

EC axial
S series
Q-motor
 "V"

ESM
EC-SYSTEMS
Accessories
Technology
Contacts

105
AC axial fans
S series, Ø 630, drawings for direction of air flow "A"

Type Mass
Without attachments [kg] c d g
A6D 630-AE01 -02 12.5 142.0 116.0 208.5
A6D 630-AF01 -02 12.5 134.0 96.0 208.5
A6D 630-AA01 -02 14.0 149.0 135.0 223.5
A8D 630-AD01 -02 12.5 149.0 135.0 208.5
A8D 630-AE01 -02 12.5 142.0 116.0 208.5
A6E 630-AE01 -02 12.5 142.0 116.0 208.5
A6E 630-AF01 -02 12.5 134.0 96.0 208.5
A6E 630-AA03 -02 14.0 149.0 135.0 223.5
A8E 630-AE01 -02 12.5 142.0 116.0 208.5

Depth of screw
max. 12 mm
Cable gland

"A" 

Type Mass
With full square nozzle [kg]
W6D 630-DE01 -02 21.0
W6D 630-DF01 -02 21.0
W6D 630-DA01 -02 23.5
W8D 630-DD01 -02 21.0
W8D 630-DE01 -02 21.0
W6E 630-DE01 -02 21.0
W6E 630-DF01 -02 21.0
W6E 630-DA03 -02 23.5
W8E 630-DE01 -02 21.0

"A" 

Type Mass
With guard grille for full nozzle [kg] s t
S6D 630-BE01 -02 14.5 164.0 162.0
S6D 630-BF01 -02 14.5 164.0 154.0
S6D 630-BA01 -02 17.0 179.0 169.0
S8D 630-BD01 -02 14.5 164.0 169.0
S8D 630-BE01 -02 14.5 164.0 162.0
S6E 630-BE01 -02 14.5 164.0 162.0
S6E 630-BF01 -02 14.5 164.0 154.0
S6E 630-BA03 -02 17.0 179.0 169.0
S8E 630-BE01 -02 14.5 164.0 162.0

"A" 

106
information
General
AC axial fans
Type Mass
With guard grille for short nozzle [kg] u v
S6D 630-AE01 -02 15.0 92.0 94.0
S6D 630-AF01 -02 15.0 84.0 94.0
S6D 630-AA01 -02 17.5 99.0 109.0

AC axial
S series
S8D 630-AD01 -02 15.0 99.0 94.0
S8D 630-AE01 -02 15.0 92.0 94.0
S6E 630-AE01 -02 15.0 92.0 94.0
S6E 630-AF01 -02 15.0 84.0 94.0
S6E 630-AA03 -02 17.5 99.0 109.0
S8E 630-AE01 -02 15.0 92.0 94.0

AC axial
K series
AC axial
A series
"A" 

EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

107
AC axial fans
S series, Ø 710

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A µF/VDB Pa °C p. 416 f.

A 3~ 400 ∆ 50 1350 2.32 4.65 — 280 -40 to +70


*4D 710 M4D 138-LA -10° B 3~ 400 Y 50 1090 1.59 2.78 — 180 -40 to +70 F1b)/F2b)
C 3~ 400 ∆ 50 910 1.01 2.40 — 130 -40 to +80
*6D 710 M6D 138-HF -5° D 3~ 400 Y 50 750 0.70 1.33 — 87 -40 to +80 F1b)/F2b)
subject to alterations (1) Nominal data in operating point 3 with maximum load

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

1380 1.96 4.13 82


[Pa]

[in H O]

A 1
2

3 A 2 1360 2.21 4.49 86


A 3 1350 2.32 4.65 87
1,0

250 2
B 1 1160 1.43 2.50 78
A B 2 1110 1.55 2.70 80
B 3 1090 1.59 2.78 81
0,8

200

2
0,6

150 1
B

1
0,4

100
0,2

50

0 2000 4000 6000 8000 10000 12000 [CFM]

4000 8000 12000 16000 20000 [m3/h]

-10˚ -5˚ 0˚

108
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A"  "A"   "V"
Without With full With guard grille With guard grille With guard grille With guard grille In-line duct fan
attachments square nozzle for full nozzle for short nozzle for full nozzle for short nozzle

EC axial fans
"V" A4D 710-AL01 -01 W4D 710-GL01 -01 S4D 710-CL01 -01 S4D 710-AL01 -01 — — W4D 710-IL01 -01
"A" A4D 710-AL01 -02 W4D 710-DL01 -02 — — S4D 710-BL01 -02 — —
"V" A6D 710-AN01 -01 W6D 710-GN01 -01 S6D 710-CN01 -01 S6D 710-AN01 -01 — — W6D 710-IN01 -01
"A" A6D 710-AN01 -02 W6D 710-DN01 -02 — — S6D 710-BN01 -02 — —

EC axial
S series
Q-motor
n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

925 0.91 2.32 72


[Pa]

[in H O]

C 1
2

ESM
C 2 920 0.97 2.38 75
140 C 3 910 1.01 2.40 77
3
D 1 780 0.65 1.22 69
0,5

120
D 2 765 0.68 1.27 71
2
750 0.70 1.33 72
EC-SYSTEMS
D 3

C
0,4

100
3
1
80 2
0,3

D
Accessories

60 1
0,2

40
0,1

20
Technology

0 2500 5000 7500 10000 [CFM]

4000 8000 12000 16000 [m3/h]

-10˚ -5˚ 0˚
Contacts

109
Drawings Speed setting Motor protection Electr. connections
p. 110 ff. p. 384 f. p. 386 ff. p. 416 f.
AC axial fans
S series, Ø 710, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] g
A4D 710-AL01 -01 25.0 276.0
A6D 710-AN01 -01 21.0 251.0

Depth of screw
max. 18 mm
Cable gland

 "V"

Type Mass
With full square nozzle [kg]
W4D 710-GL01 -01 43.0
W6D 710-GN01 -01 39.0

 "V"

Type Mass
With guard grille for full nozzle [kg] t
S4D 710-CL01 -01 34.0 193.5
68
S6D 710-CN01 -01 30.0 168.5
7,5

15,5
26
10

View X

92

 "V"

110
information
General
AC axial fans
Type Mass
With guard grille for short nozzle [kg] u v
S4D 710-AL01 -01 35.5 31.0 90.0
S6D 710-AN01 -01 31.5 27.0 65.0

AC axial
S series
AC axial
K series
AC axial
A series
 "V"

Type Mass
In-line duct fan

EC axial fans
[kg]
W4D 710-IL01 -01 40.0
W6D 710-IN01 -01 36.0

EC axial
S series
Q-motor
 "V"

ESM
EC-SYSTEMS
Accessories
Technology
Contacts

111
AC axial fans
S series, Ø 710, drawings for direction of air flow "A"

Type Mass
Without attachments [kg] g
A4D 710-AL01 -02 25.0 276.0
A6D 710-AN01 -02 21.0 251.0

Depth of screw
Cable gland max. 18 mm

"A" 

Type Mass
With full square nozzle [kg]
W4D 710-DL01 -02 44.0
W6D 710-DN01 -02 40.0

"A" 

Type Mass
With guard grille for full nozzle [kg] s t
S4D 710-BL01 -02 35.0 144.0 160.0
S6D 710-BN01 -02 32.0 154.0 155.0

"A" 

112
113
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
S series, Ø 800

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A µF/VDB Pa °C p. 416 f.

A 3~ 400 ∆ 50 870 1.45 3.20 — 150 -40 to +60


*6D 800 M6D 138-HF -5° B 3~ 400 Y 50 610 0.81 1.64 — 75 -40 to +60 F1b)/F2b)
C 3~ 400 ∆ 50 895 1.14 2.45 — 160 -40 to +75
*6D 800 M6D 138-HF -10° D 3~ 400 Y 50 710 0.75 1.45 — 98 -40 to +75 F1b)/F2b)
E 3~ 400 ∆ 50 895 2.00 4.30 — 180 -40 to +60
*6D 800 M6D 138-LA 0° F 3~ 400 Y 50 685 1.27 2.50 — 100 -40 to +60 F1b)/F2b)
G 3~ 400 ∆ 50 910 2.18 5.17 — 120 -40 to +55
*6D 800 M6D 138-NA +5° H 3~ 400 Y 50 730 1.47 2.80 — 75 -40 to +55 F1b)/F2b)
I 3~ 400 ∆ 50 915 2.08 4.62 — 180 -40 to +60
*6D 800 M6D 138-NA 0° J 3~ 400 Y 50 740 1.43 2.66 — 118 -40 to +60 F1b)/F2b)
subject to alterations (1) Nominal data in operating point 3 with maximum load

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

910 1.07 2.50 72


[Pa]

[in H O]

A 1
2

A 2 890 1.23 2.69 72


3
180 A 3 870 1.45 3.20 74

3 E
B 1 745 0.72 1.35 68
160
B 2 690 0.79 1.49 66
0,6

140
C
A
B 3 610 0.81 1.64 67
2 2 C 1 920 0.94 2.29 74
120 C 2 910 1.04 2.40 75
C 3 895 1.14 2.45 78
3 2
0,4

100 3 D 1 770 0.66 1.24 70


2 F 1
D 2 735 0.71 1.34 70
80 3 2
D 3 710 0.75 1.45 71

2
E 1 915 1.55 3.48 71
60 1 B
1 E 2 900 1.75 3.72 72
0,2

40 1
E 3 895 2.00 4.30 78
1
D F 1 750 1.08 2.02 68
1
20 F 2 705 1.16 2.17 67
F 3 685 1.27 2.50 72

0 4000 8000 12000 16000 [CFM]

5000 10000 15000 20000 25000 [m3/h]

-10˚ -5˚ 0˚

114
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A"  "A"   "V"
Without With full With guard grille With guard grille With guard grille With guard grille In-line duct fan
attachments square nozzle for full nozzle for short nozzle for full nozzle for short nozzle

EC axial fans
"V" A6D 800-AN01 -01 W6D 800-GN01 -01 S6D 800-CN01 -01 S6D 800-AN01 -01 — — —
"A" A6D 800-AN01 -02 W6D 800-DN01 -02 — — S6D 800-BN01 -02 — —
"V" A6D 800-AO01 -01 W6D 800-GO01 -01 S6D 800-CO01 -01 S6D 800-AO01 -01 — — —
"A" A6D 800-AO01 -02 W6D 800-DO01 -02 — — S6D 800-BO01 -02 — —
"V" A6D 800-AJ01 -01 W6D 800-GJ01 -01 S6D 800-CJ01 -01 S6D 800-AJ01 -01 — — W6D 800-IJ01 -01
"A" A6D 800-AJ01 -02 W6D 800-DJ01 -02 — — S6D 800-BJ01 -02 — —
"V" A6D 800-AS01 -01 W6D 800-GS01 -01 S6D 800-CS01 -01 S6D 800-AS01 -01 — — —

EC axial
S series
"A" A6D 800-AS01 -02 W6D 800-DS01 -02 — — S6D 800-BS01 -02 — —
"V" A6D 800-AP01 -01 W6D 800-GP01 -01 S6D 800-CP01 -01 S6D 800-AP01 -01 — — —
"A" A6D 800-AP01 -02 W6D 800-DP01 -02 — — S6D 800-BP01 -02 — —

Q-motor
n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

920 2.01 4.99 74


[Pa]

[in H O]

G 1
2

ESM
G 2 915 2.11 5.15 74
180 G 3 910 2.18 5.17 75
I
H 1 755 1.40 2.68 69
160
H 2 740 1.44 2.75 69
0,6

730 1.47 2.80 71


EC-SYSTEMS
H 3
140 2
I 1 940 1.63 4.26 72
3
120 J 3 I 2 925 1.85 4.47 73
G
I 3 915 2.08 4.62 79
0,4

100 J 1 810 1.22 2.25 69


2
2
J 2 775 1.33 2.44 70
Accessories

80 3 J 3 740 1.43 2.66 73

60 2
1
1
0,2

40 1
1
H
Technology

20

0 4000 8000 12000 16000 [CFM]

5000 10000 15000 20000 25000 [m3/h]

-10˚ -5˚ 0˚ +5˚


Contacts

115
Drawings Speed setting Motor protection Electr. connections
p. 118 ff. p. 384 f. p. 386 ff. p. 416 f.
AC axial fans
S series, Ø 800

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A µF/VDB Pa °C p. 416 f.

A 3~ 400 ∆ 50 680 0.79 2.15 — 100 -40 to +55


*8D 800 M8D 138-HF -5° B 3~ 400 Y 50 540 0.48 1.05 — 60 -40 to +55 F1b)/F2b)
C 3~ 400 ∆ 50 665 1.05 2.70 — 80 -40 to +70
*8D 800 M8D 138-LA +5° D 3~ 400 Y 50 500 0.63 1.31 — 45 -40 to +70 F1b)/F2b)
E 3~ 400 ∆ 50 660 0.98 2.41 — 105 -40 to +65
*8D 800 M8D 138-LA 0° F 3~ 400 Y 50 515 0.57 1.21 — 57 -40 to +65 F1b)/F2b)
G 3~ 400 ∆ 50 435 0.37 1.15 — 44 -40 to +80
*ZD 800 MZD 138-HF 0° H 3~ 400 Y 50 330 0.20 0.48 — 25 -40 to +80 F1b)/F2b)
subject to alterations (1) Nominal data in operating point 3 with maximum load

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

700 0.60 2.08 67


[Pa]

[in H O]

A 1
2

A 2 690 0.68 2.10 67


3
A 3 680 0.79 2.15 71
100
0,4

3 E B 1 605 0.40 0.87 64


B 2 575 0.44 0.94 63
A
B 3 540 0.48 1.05 65
80
2 3 C 1 680 0.96 2.57 68
0,3

C
C 2 670 1.01 2.61 69
C 3 665 1.05 2.70 71
60 33 2
F 2 D 1 525 0.60 1.26 63
D 2 510 0.62 1.29 63
0,2

2 D 3 500 0.63 1.31 64


3
40 2
E 1 690 0.76 2.21 67
2 1
1 E 2 680 0.85 2.28 67
B E 3 660 0.98 2.41 71
0,1

1
20 1 1
1 F 1 560 0.50 1.06 63
F 2 530 0.54 1.13 62
D F 3 515 0.57 1.21 64

0 4000 8000 12000 [CFM]

4000 8000 12000 16000 20000 [m3/h]

-10˚ -5˚ 0˚ +5˚

116
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A"  "A"   "V"
Without With full With guard grille With guard grille With guard grille With guard grille In-line duct fan
attachments square nozzle for full nozzle for short nozzle for full nozzle for short nozzle

EC axial fans
"V" A8D 800-AN01 -01 W8D 800-GN01 -01 S8D 800-CN01 -01 S8D 800-AN01 -01 — — —
"A" A8D 800-AN01 -02 W8D 800-DN01 -02 — — S8D 800-BN01 -02 — —
"V" A8D 800-AT03 -01 W8D 800-GT03 -01 S8D 800-CT03 -01 S8D 800-AT03 -01 — — —
"A" A8D 800-AT03 -02 W8D 800-DT03 -02 — — S8D 800-BT03 -02 — —
"V" A8D 800-AJ01 -01 W8D 800-GJ01 -01 S8D 800-CJ01 -01 S8D 800-AJ01 -01 — — —
"A" A8D 800-AJ01 -02 W8D 800-DJ01 -02 — — S8D 800-BJ01 -02 — —
"V" AZD 800-AM03 -01 WZD 800-GM03 -01 SZD 800-CM03 -01 SZD 800-AM03 -01 — — —

EC axial
S series
"A" AZD 800-AM03 -02 WZD 800-DM03 -02 — — SZD 800-BM03 -02 — —

Q-motor
n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

455 0.31 1.09 59


[Pa]

[in H O]

G 1
2

ESM
G 2 445 0.33 1.10 58
45
3 G 3 435 0.37 1.15 61
G
40
H 1 375 0.17 0.43 55
H 2 360 0.18 0.45 55
0,15

330 0.20 0.48 55


EC-SYSTEMS
35 H 3

2
30

3
25
0,1

H
Accessories

2
20

15
1
0,05

10
1
Technology

0 2000 4000 6000 [CFM]

2000 4000 6000 8000 10000 12000 [m3/h]

-10˚ -5˚ 0˚
Contacts

117
Drawings Speed setting Motor protection Electr. connections
p. 118 ff. p. 384 f. p. 386 ff. p. 416 f.
AC axial fans
S series, Ø 800, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] c d g
A6D 800-AN01 -01 22.0 147.0 133.0 251.0
A6D 800-AO01 -01 22.0 142.0 118.0 251.0
A6D 800-AJ01 -01 26.0 152.0 147.0 276.0
A6D 800-AS01 -01 29.0 157.0 162.0 296.0
A6D 800-AP01 -01 29.0 152.0 147.0 296.0
A8D 800-AN01 -01 22.0 147.0 133.0 251.0
A8D 800-AT03 -01 26.0 157.0 162.0 276.0
A8D 800-AJ01 -01 26.0 152.0 147.0 276.0
AZD 800-AM03 -01 22.0 152.0 147.0 251.0

Depth of screw
max. 18 mm
Cable gland

 "V"

Type Mass
With full square nozzle [kg]
W6D 800-GN01 -01 42.0
W6D 800-GO01 -01 42.0
W6D 800-GJ01 -01 46.0
W6D 800-GS01 -01 49.0
W6D 800-GP01 -01 49.0
W8D 800-GN01 -01 42.0
W8D 800-GT03 -01 46.0
W8D 800-GJ01 -01 46.0
WZD 800-GM03 -01 42.0

 "V"

Type Mass
With guard grille for full nozzle [kg] s t
S6D 800-CN01 -01 32.0 136.5 165.5
68
S6D 800-CO01 -01 32.0 131.5 165.5
7,5

15,5
26
15

View X S6D 800-CJ01 -01 36.0 141.5 190.5


S6D 800-CS01 -01 39.0 146.5 210.5
92
S6D 800-CP01 -01 39.0 141.5 210.5
S8D 800-CN01 -01 32.0 136.5 165.5
S8D 800-CT03 -01 36.0 146.5 190.5
S8D 800-CJ01 -01 36.0 141.5 190.5
SZD 800-CM03 -01 32.0 141.5 165.5

 "V"

118
information
General
AC axial fans
Type Mass
With guard grille for short nozzle [kg] u v
S6D 800-AN01 -01 34.0 17.0 51.0
S6D 800-AO01 -01 34.0 17.0 51.0
S6D 800-AJ01 -01 38.0 27.0 76.0

AC axial
S series
S6D 800-AS01 -01 41.0 32.0 96.0
S6D 800-AP01 -01 41.0 27.0 96.0
S8D 800-AN01 -01 34.0 22.0 51.0
S8D 800-AT03 -01 38.0 32.0 76.0
S8D 800-AJ01 -01 38.0 27.0 76.0
SZD 800-AM03 -01 34.0 17.0 51.0

AC axial
K series
AC axial
A series
 "V"

Type Mass
In-line duct fan

EC axial fans
[kg]
W6D 800-IJ01 -01 43.8

EC axial
S series
Q-motor
 "V"

ESM
EC-SYSTEMS
Accessories
Technology
Contacts

119
AC axial fans
S series, Ø 800, drawings for direction of air flow "A"

Type Mass
Without attachments [kg] c d g
A6D 800-AN01 -02 22.0 175.0 133.0 251.0
A6D 800-AO01 -02 22.0 165.0 188.0 251.0
A6D 800-AJ01 -02 26.0 185.0 147.0 276.0
A6D 800-AS01 -02 29.0 194.0 162.0 296.0
A6D 800-AP01 -02 29.0 185.0 147.0 296.0
A8D 800-AN01 -02 22.0 175.0 133.0 251.0
A8D 800-AT03 -02 26.0 194.0 162.0 276.0
A8D 800-AJ01 -02 26.0 185.0 147.0 276.0
AZD 800-AM03 -02 22.0 185.0 147.0 251.0

Depth of screw
Cable gland max. 18 mm

"A" 

Type Mass
With full square nozzle [kg]
W6D 800-DN01 -02 43.5
W6D 800-DO01 -02 43.5
W6D 800-DJ01 -02 47.5
W6D 800-DS01 -02 50.5
W6D 800-DP01 -02 50.5
W8D 800-DN01 -02 43.5
W8D 800-DT03 -02 47.5
W8D 800-DJ01 -02 47.5
WZD 800-DM03 -02 43.5

"A" 

Type Mass
With guard grille for full nozzle [kg] s t
S6D 800-BN01 -02 33.0 172.0 173.0
S6D 800-BO01 -02 33.0 162.0 173.0
S6D 800-BJ01 -02 37.0 182.0 198.0
S6D 800-BS01 -02 40.0 191.0 218.0
S6D 800-BP01 -02 40.0 182.0 218.0
S8D 800-BN01 -02 34.0 172.0 173.0
S8D 800-BT03 -02 37.0 191.0 198.0
S8D 800-BJ01 -02 37.0 182.0 198.0
SZD 800-BM03 -02 34.0 182.0 173.0

"A" 

120
121
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
S series, Ø 910

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A µF/VDB Pa °C p. 416 f.

A 3~ 400 ∆ 50 880 1.30 2.75 — 150 -40 to +60


*6D 910 M6D 138-HF -10° B 3~ 400 Y 50 670 0.81 1.56 — 85 -40 to +60 F1b)/F2b)
C 3~ 400 ∆ 50 900 1.84 3.76 — 150 -40 to +60
*6D 910 M6D 138-LA -5° D 3~ 400 Y 50 700 1.20 2.24 — 88 -40 to +60 F1b)/F2b)
E 3~ 400 ∆ 50 930 1.41 3.20 — 165 -40 to +75
*6D 910 M6D 138-LA -10° F 3~ 400 Y 50 780 1.03 1.90 — 115 -40 to +75 F1b)/F2b)
G 3~ 400 ∆ 50 890 2.45 5.20 — 160 -40 to +50
*6D 910 M6D 138-NA 0° H 3~ 400 Y 50 685 1.56 2.90 — 95 -40 to +50 F1b)/F2b)
I 3~ 400 ∆ 50 920 1.96 4.50 — 170 -40 to +60
*6D 910 M6D 138-NA -5° J 3~ 400 Y 50 760 1.37 2.55 — 115 -40 to +60 F1b)/F2b)
K 3~ 400 ∆ 50 940 1.53 4.45 — 170 -40 to +70
*6D 910 M6D 138-NA -10° L 3~ 400 Y 50 830 1.14 2.15 — 130 -40 to +70 F1b)/F2b)
subject to alterations (1) Nominal data in operating point 3 with maximum load

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

910 1.06 2.56 77


[Pa]

[in H O]

A 1
2

E 3
A 2 890 1.21 2.72 78
160
3 A 3 880 1.30 2.75 82
0,6

3
C B 1 740 0.72 1.36 72
140
B 2 700 0.78 1.47 72
F
A 2
B 3 670 0.81 1.56 74
2
120 3
2 C 1 920 1.59 3.51 76
C 2 910 1.72 3.67 77
0,4

100 C 3 900 1.84 3.76 79


3 2
1
3
D 1 745 1.10 2.01 71
80
2 D 2 720 1.15 2.11 71
B
2 D 3 700 1.20 2.24 72
1 1
60
1 E 1 945 1.11 2.91 78
0,2

1 E 2 935 1.27 3.08 79


40 1
E 3 930 1.41 3.20 83
F 1 840 0.85 1.56 75
20 F 2 805 0.96 1.74 75
D
F 3 780 1.03 1.90 78

0 4000 8000 12000 16000 [CFM]

5000 10000 15000 20000 25000 [m3/h]

-10˚ -5˚ 0˚

122
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A"  "A"   "V"
Without With full With guard grille With guard grille With guard grille With guard grille In-line duct fan
attachments square nozzle for full nozzle for short nozzle for full nozzle for short nozzle

EC axial fans
"V" A6D 910-AO01 -01 W6D 910-GO01 -01 S6D 910-CO01 -01 S6D 910-AO01 -01 — — —
"A" A6D 910-AO01 -02 W6D 910-DO01 -02 — — S6D 910-BO01 -02 — —
"V" A6D 910-AK01 -01 W6D 910-GK01 -01 S6D 910-CK01 -01 S6D 910-AK01 -01 — — —
"A" A6D 910-AK01 -02 W6D 910-DK01 -02 — — S6D 910-BK01 -02 — —
"V" A6D 910-AL01 -01 W6D 910-GL01 -01 S6D 910-CL01 -01 S6D 910-AL01 -01 — — —
"A" A6D 910-AL01 -02 W6D 910-DL01 -02 — — S6D 910-BL01 -02 — —
"V" A6D 910-AP01 -01 W6D 910-GP01 -01 S6D 910-CP01 -01 S6D 910-AP01 -01 — — —

EC axial
S series
"A" A6D 910-AP01 -02 W6D 910-DP01 -02 — — S6D 910-BP01 -02 — —
"V" A6D 910-AQ01 -01 W6D 910-GQ01 -01 S6D 910-CQ01 -01 S6D 910-AQ01 -01 — — —
"A" A6D 910-AQ01 -02 W6D 910-DQ01 -02 — — S6D 910-BQ01 -02 — —
"V" A6D 910-AR01 -01 W6D 910-GR01 -01 S6D 910-CR01 -01 S6D 910-AR01 -01 — — —
"A" A6D 910-AR01 -02 W6D 910-DR01 -02 — — S6D 910-BR01 -02 — —

Q-motor
n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

920 1.99 4.65 76


[Pa]

[in H O]

G 1
2

ESM
G 2 905 2.24 4.95 76
180
3 3 G 3 890 2.45 5.20 79
3
160 H 1 760 1.39 2.57 72
G H 2 725 1.49 2.76 70
0,6

685 1.56 2.90 72


EC-SYSTEMS
140 K H 3
3 2
2 I 1 940 1.64 4.33 77
120 3 I 2 930 1.82 4.51 78
J
2 I 3 920 1.96 4.50 80
100 2 I
0,4

3
2 J 1 810 1.20 2.23 73
J 2 780 1.30 2.40 73
Accessories

80 1

1
J 3 760 1.37 2.55 75
L 2
60 1 H K 1 960 1.24 4.27 78
1
K 2 950 1.40 4.35 80
0,2

1
40 K 3 940 1.53 4.45 83
1
L 1 875 0.94 1.79 76
Technology

20 L 2 850 1.05 1.97 77


L 3 830 1.14 2.15 80

0 4000 8000 12000 16000 [CFM]

5000 10000 15000 20000 25000 30000 [m3/h]

-10˚ -5˚ 0˚
Contacts

123
Drawings Speed setting Motor protection Electr. connections
p. 126 ff. p. 384 f. p. 386 ff. p. 416 f.
AC axial fans
S series, Ø 910

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Encased in aluminium
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" clockwise, direction of air flow "A"
counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
Nominal voltage

Speed/rpm (1)

Max. current
Blade angle

Max. power
Frequency

Capacitor
draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A µF/VDB Pa °C p. 416 f.

A 3~ 400 ∆ 50 645 0.85 2.09 — 90 -40 to +60


*8D 910 M8D 138-HF -5° B 3~ 400 Y 50 450 0.45 1.00 — 43 -40 to +60 F1b)/F2b)
C 3~ 400 ∆ 50 665 1.11 2.70 — 90 -40 to +65
*8D 910 M8D 138-LA 0° D 3~ 400 Y 50 495 0.68 1.36 — 50 -40 to +65 F1b)/F2b)
E 3~ 400 ∆ 50 425 0.42 1.15 — 40 -40 to +70
*ZD 910 MZD 138-HF 0° F 3~ 400 Y 50 315 0.22 0.50 — 21 -40 to +70 F1b)/F2b)
G 3~ 400 ∆ 50 430 0.32 0.86 — 42 -40 to +100
*ZD 910 MZD 138-HF -5° H 3~ 400 Y 50 320 0.17 0.40 — 22 -40 to +100 F1b)/F2b)
subject to alterations (1) Nominal data in operating point 3 with maximum load

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

670 0.73 1.94 68


[Pa]

[in H O]

A 1
3 3
2

A 2 655 0.80 2.03 68


90
A 3 645 0.85 2.09 69

80
B 1 500 0.43 0.95 62
B 2 460 0.44 0.99 60
0,3

2
70 2
B 3 450 0.45 1.00 60
C C 1 685 0.94 2.49 69
60 C 2 675 1.03 2.57 69
A
3
C 3 665 1.11 2.70 71
50
0,2

D 1 540 0.62 1.23 64


3
2 1 1 D 2 515 0.65 1.30 63
40
B
D D 3 495 0.68 1.36 64
2

30
1
0,1

1
20

10

0 2000 4000 6000 8000 10000 12000 [CFM]

4000 8000 12000 16000 20000 [m3/h]

-10˚ -5˚ 0˚

124
information
General
AC axial fans
– Motor protection: Design with thermal overload protector
– Cable exit: Via terminal box
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A"  "A"   "V"
Without With full With guard grille With guard grille With guard grille With guard grille In-line duct fan
attachments square nozzle for full nozzle for short nozzle for full nozzle for short nozzle

EC axial fans
"V" A8D 910-AN07 -01 W8D 910-GN07 -01 S8D 910-CN07 -01 S8D 910-AN07 -01 — — —
"A" A8D 910-AN07 -02 W8D 910-DN07 -02 — — S8D 910-BN07 -02 — —
"V" A8D 910-AJ03 -01 W8D 910-GJ03 -01 S8D 910-CJ03 -01 S8D 910-AJ03 -01 — — —
"A" A8D 910-AJ03 -02 W8D 910-DJ03 -02 — — S8D 910-BJ03 -02 — —
"V" AZD 910-AM03 -01 WZD 910-GM03 -01 SZD 910-CM03 -01 SZD 910-AM03 -01 — — —
"A" AZD 910-AM03 -02 WZD 910-DM03 -02 — — SZD 910-BM03 -02 — —
"V" AZD 910-AN05 -01 WZD 910-GN05 -01 SZD 910-CN05 -01 SZD 910-AN05 -01 — — —

EC axial
S series
"A" AZD 910-AN05 -02 WZD 910-DN05 -02 — — SZD 910-BN05 -02 — —

Q-motor
n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

445 0.36 1.11 61


[Pa]

[in H O]

E 1
2

ESM
E 2 435 0.39 1.13 59
45
E 3 425 0.42 1.15 61
3

40
3 F 1 345 0.20 0.46 54
F 2 330 0.21 0.48 53
0,15

315 0.22 0.50 53


EC-SYSTEMS
35 F 3
G E
G 1 450 0.27 0.81 60
30 2 G 2 440 0.29 0.84 59
2

H
G 3 430 0.32 0.86 61
25
0,1

H 1 360 0.16 0.36 54


3
3 H 2 340 0.17 0.38 53
Accessories

F
20
1
H 3 320 0.17 0.40 53
2
2 1
15
0,05

1
10 1
Technology

0 2000 4000 6000 8000 [CFM]

2000 4000 6000 8000 10000 12000 14000 [m3/h]

-10˚ -5˚ 0˚
Contacts

125
Drawings Speed setting Motor protection Electr. connections
p. 126 ff. p. 384 f. p. 386 ff. p. 416 f.
AC axial fans
S series, Ø 910, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] c d g
A6D 910-AO01 -01 22.0 147.0 104.0 251.0
A6D 910-AK01 -01 27.0 152.0 115.0 276.0
A6D 910-AL01 -01 27.0 147.0 104.0 276.0
A6D 910-AP01 -01 30.0 156.0 123.0 296.0
A6D 910-AQ01 -01 30.0 152.0 115.0 296.0
A6D 910-AR01 -01 30.0 147.0 104.0 296.0
A8D 910-AN07 -01 22.0 152.0 115.0 251.0
A8D 910-AJ03 -01 27.0 156.0 123.0 276.0
AZD 910-AM03 -01 22.0 157.0 123.0 251.0
AZD 910-AN05 -01 22.0 152.0 115.0 251.0

Depth of screw
max. 18 mm
Cable gland

 "V"

Type Mass
With full square nozzle [kg]
W6D 910-GO01 -01 42.0
W6D 910-GK01 -01 47.0
W6D 910-GL01 -01 47.0
W6D 910-GP01 -01 50.0
W6D 910-GQ01 -01 50.0
W6D 910-GR01 -01 50.0
W8D 910-GN07 -01 42.0
W8D 910-GJ03 -01 47.0
WZD 910-GM03 -01 42.0
WZD 910-GN05 -01 42.0

 "V"

Type Mass
With guard grille for full nozzle [kg] s t
S6D 910-CO01 -01 33.0 134.0 163.0
76
S6D 910-CK01 -01 38.0 139.0 188.0
10

20
29
15

View X S6D 910-CL01 -01 38.0 134.0 188.0


S6D 910-CP01 -01 41.0 143.0 208.0
116
S6D 910-CQ01 -01 41.0 139.0 208.0
S6D 910-CR01 -01 41.0 134.0 208.0
S8D 910-CN07 -01 33.0 139.0 163.0
S8D 910-CJ03 -01 38.0 143.0 188.0
SZD 910-CM03 -01 33.0 143.0 163.0
SZD 910-CN05 -01 33.0 139.0 163.0

 "V"

126
information
General
AC axial fans
Type Mass
With guard grille for short nozzle [kg] u v
S6D 910-AO01 -01 35.0 17.0 46.0
S6D 910-AK01 -01 40.0 22.0 71.0
S6D 910-AL01 -01 40.0 17.0 71.0

AC axial
S series
S6D 910-AP01 -01 43.0 26.0 91.0
S6D 910-AQ01 -01 43.0 22.0 91.0
S6D 910-AR01 -01 43.0 17.0 91.0
S8D 910-AN07 -01 35.0 22.0 46.0
S8D 910-AJ03 -01 40.0 26.0 71.0
SZD 910-CM03 -01 35.0 26.0 46.0

AC axial
K series
SZD 910-CN05 -01 35.0 22.0 46.0

AC axial
A series
 "V"

EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

127
AC axial fans
S series, Ø 910, drawings for direction of air flow "A"

Type Mass
Without attachments [kg] c d g
A6D 910-AO01 -02 22.0 145.0 104.0 251.0
A6D 910-AK01 -02 27.0 154.0 115.0 276.0
A6D 910-AL01 -02 27.0 145.0 104.0 276.0
A6D 910-AP01 -02 30.0 157.0 123.0 296.0
A6D 910-AQ01 -02 30.0 154.0 115.0 296.0
A6D 910-AR01 -02 30.0 145.0 104.0 296.0
A8D 910-AN07 -02 22.0 154.0 115.0 251.0
A8D 910-AJ03 -02 27.0 157.0 123.0 276.0
AZD 910-AM03 -02 22.0 157.0 123.0 251.0
AZD 910-AN05 -02 22.0 154.0 115.0 251.0

Depth of screw
Cable gland max. 18 mm

"A" 

Type Mass
With full square nozzle [kg]
W6D 910-DO01 -02 43.5
W6D 910-DK01 -02 48.5
W6D 910-DL01 -02 48.5
W6D 910-DP01 -02 51.5
W6D 910-DQ01 -02 51.5
W6D 910-DR01 -02 51.5
W8D 910-DN07 -02 43.5
W8D 910-DJ03 -02 48.5
WZD 910-DM03 -02 43.5
WZD 910-DN05 -02 43.5

"A" 

Type Mass
With guard grille for full nozzle [kg] s t
S6D 910-BO01 -02 34.0 159.0 195.0
S6D 910-BK01 -02 39.0 168.0 215.0
S6D 910-BL01 -02 39.0 159.0 215.0
S6D 910-BP01 -02 42.0 171.0 235.0
S6D 910-BQ01 -02 42.0 168.0 235.0
S6D 910-BR01 -02 42.0 159.0 235.0
S8D 910-BN07 -02 34.0 168.0 195.0
S8D 910-BJ03 -02 39.0 171.0 215.0
SZD 910-BM03 -02 34.0 171.0 195.0
SZD 910-BN05 -02 34.0 168.0 195.0

"A" 

128
129
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
130
AC axial fans K series

AC axial fans, K series


Ø 250 - Ø 450

131
132

Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
K series, Ø 250 / 300

– Material: Guard grille: Steel, phosphated and coated in black plastic


Blades: PA plastic, black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

1~ 230 50 800 1350 41 0.18 1.5 /400 47 60 -25 to +60


*4E 250 M4E 068-BF A
1~ 230 60 910 1550 50 0.23 1.5 /400 50 60 -25 to +70 1.2 A1)
1~ 230 50 1100 1100 52 0.23 1.5 /400 53 50 -25 to +45
*4E 300-*E M4E 068-BF B
1~ 230 60 1150 1150 60 0.27 1.5 /400 54 50 -25 to +40 1.3 A1)
1~ 230 50 1340 1350 70 0.31 1.5 /400 58 80 -25 to +60
*4E 300-*H M4E 068-CF C
1~ 230 60 1460 1480 90 0.40 1.5 /400 61 65 -25 to +55 1.7 A1)
subject to alterations

n P1 I
Curves [rpm] [W] [A]

A 1 1315 42 0.19
[Pa]

[in H O]
2

A 2 1280 44 0.20
80
0,3

60
0,2

40
A
0,1

20 1

0 100 200 300 400 500 [CFM]

200 400 600 800 [m3/h]

50 Hz 60 Hz

132
information
General
AC axial fans
– Motor protection: TOP wired internally
– Cable exit: A C Axial, B variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A" 
Without With guard grille
attachments for short nozzle

EC axial fans
"V" A4E 250-AE32 -05 S4E 250-AE32 -01
"A" A4E 250-AE32 -06 S4E 250-AE32 -02
"V" A4E 300-AE20 -05 S4E 300-EE20 -05
"A" A4E 300-AE20 -06 S4E 300-EE20 -06
"V" A4E 300-AH26 -05 S4E 300-EH26 -05
"A" A4E 300-AH26 -06 S4E 300-EH26 -06

EC axial
S series
Q-motor
n P1 I
Curves [rpm] [W] [A]

B 1 1060 53 0.24
[Pa]

[in H O]
2

ESM
B 2 985 55 0.24
80
C 1 1325 71 0.32
0,3

C 2 1310 73 0.33
EC-SYSTEMS

60
0,2

40 2
C
Accessories

B
1,0

20 1 1
Technology

0 200 400 600 [CFM]

300 600 900 1200 [m3/h]

50 Hz 60 Hz
Contacts

133
Drawings Guard grille Terminal box Capacitor Electr. connections
p. 134 f. p. 366 p. 381 p. 382 f. p. 416 f.
AC axial fans
K series, Ø 250 / 300, drawings of directions of air flow "V" and "A"

Type
Without attachments a b c1 j
A4E 250-AE32 -05 "V" 68.0 250.0 -9.0 63.0
Depth of screw
A4E 250-AE32 -06 "A" 68.0 250.0 -2.0 63.0
- 0 + max. 5 mm
A4E 300-AE20 -05 "V" 75.0 294.0 -9.0 63.0
c1 ±3
A4E 300-AE20 -06 "A" 75.0 294.0 -3.0 63.0
Brass lead tips A4E 300-AH26 -05 "V" 75.0 294.0 -4.0 73.0
A4E 300-AH26 -06 "A" 75.0 294.0 -4.0 73.0
2 j ±3 M4
Ø27

4x90˚
Ø92
Øb

27,5

6
85
450

a ±3 58

 "V"
"A" 

Type Type
Installation arrangement without attachments without guard grille t x
A4E 250-AE32 -05 S4E 250-AE32 -01 "V" 32.0 260.0
t A4E 250-AE32 -06 S4E 250-AE32 -02 "A" 32.0 260.0
A4E 300-AE20 -05 S4E 300-EE20 -05 "V" 38.0 306.0
 "V" A4E 300-AE20 -06 S4E 300-EE20 -06 "A" 38.0 306.0
A4E 300-AH26 -05 S4E 300-EH26 -05 "V" 38.0 306.0
A4E 300-AH26 -06 S4E 300-EH26 -06 "A" 38.0 306.0
Øx

"A" 

134
information
General
AC axial fans
Type
With guard grille for short nozzle c2 f r s u v w
S4E 250-AE32 -01 "V" 25.0 271.0 300.0 13.5 67.5 4.5 33.5
u S4E 250-AE32 -02 "A" 36.0 271.0 300.0 13.5 67.5 4.5 33.5
v S4E 300-EE20 -05 "V" 66.0 — 360.0 12.5 30.0 4.0 26.0

AC axial
S series
S4E 300-EE20 -06 "A" 72.0 — 360.0 12.5 30.0 4.0 26.0
S4E 300-EH26 -05 "V" 71.0 — 360.0 12.5 30.0 4.0 26.0
w S4E 300-EH26 -06 "A" 71.0 — 360.0 12.5 30.0 4.0 26.0

AC axial
K series
r
f

AC axial
A series
c2 ±5 4,5
 "V" s
"A" 

EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

135
AC axial fans
K series, Ø 350

– Material: Guard grille: Steel, phosphated and coated in black plastic


Blades: PA plastic, black
Rotor: Coated in black
– Number of blades: 7
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

1~ 230 50 2390 1350 105 0.50 3.0 /400 63 80 -25 to +50


*4E 350 M4E 068-DC A
1~ 230 60 2650 1500 135 0.60 3.0 /400 66 60 -25 to +40 2.0 A1)
subject to alterations

n P1 I
Curves [rpm] [W] [A]

A 1 1335 110 0.52


[Pa]

[in H O]
2

A 2 1300 120 0.56

80
0,3

60 2
0,2

40 A
0,1

20 1

0 300 600 900 1200 1500 [CFM]

600 1200 1800 2400 [m3/h]

50 Hz 60 Hz

136
information
General
AC axial fans
– Motor protection: TOP wired internally
– Cable exit: Axial
– Protection class: I
– Product conforming to standards: EN 60335-1, CE

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A" 
Without With guard grille
attachments for short nozzle

EC axial fans
"V" A4E 350-AF20 -05 S4E 350-AF20 -01
"A" A4E 350-AF20 -06 S4E 350-AF20 -02

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

137
Drawings Guard grille Terminal box Capacitor Electr. connections
p. 138 f. p. 366 p. 381 p. 382 f. p. 416 f.
AC axial fans
K series, Ø 350, drawings of directions of air flow "V" and "A"

Type
Without attachments c1
A4E 350-AF20 -05 "V" 18.0
Depth of screw
A4E 350-AF20 -06 "A" 28.0
max. 5 mm
c1 ±3

Brass lead tips


2 83 ±3 M4
Ø350 -2

4x90˚
Ø27

Ø92

27,5

6
85
450

55 ±3 58

 "V"
"A" 

Type Type
Installation arrangement without attachments without guard grille
A4E 350-AF20 -05 S4E 350-AF20 -01 "V"
26 A4E 350-AF20 -06 S4E 350-AF20 -02 "A"
20

 "V"
Ø358

"A" 

20
26

138
61,3

 "V"
"A" 
4,5
380

c2 ±5
With guard grille for short nozzle

6,5
15,5
422
Type

S4E 350-AF20 -02


S4E 350-AF20 -01
"V"
"A"
c2

29.0
19.0

139
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
K series, Ø 360

– Material: Guard grille: Steel, phosphated and coated in black plastic


Blades: PA plastic, black
Rotor: Coated in black
– Number of blades: 3
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

1~ 230 50 2030 850 65 0.29 2.5 /400 46 40 -25 to +50


*6E 360 M6E 068-DF A
1~ 230 60 2290 960 85 0.38 2.5 /400 51 40 -25 to +40 2.0 A1)
subject to alterations

n P1 I
Curves [rpm] [W] [A]

A 1 850 65 0.29
[Pa]

[in H O]
2

A 2 820 67 0.30

40
0,15

30 2
0,10

A
20
0,05

10 1

0 250 500 750 1000 1250 [CFM]

400 800 1200 1600 2000 [m3/h]

50 Hz 60 Hz

140
information
General
AC axial fans
– Motor protection: TOP wired internally
– Cable exit: Axial
– Protection class: I
– Product conforming to standards: EN 60335-1, CE

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A" 
Without With guard grille
attachments for short nozzle

EC axial fans
"V" A6E 360-AE08 -01 S6E 360-AE08 -01
"A" A6E 360-AE08 -02 —

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

141
Drawings Guard grille Terminal box Capacitor Electr. connections
p. 142 f. p. 366 p. 381 p. 382 f. p. 416 f.
AC axial fans
K series, Ø 360, drawings of directions of air flow "V" and "A"

Type
Without attachments c1
A6E 360-AE08 -01 "V" 13.0
- 0 + Depth of screw
A6E 360-AE08 -02 "A" -42.0
max. 5 mm
c1 ±3

Brass lead tips


2,5 M4
27,5
Ø360 ±2

4x90˚
Ø 92
Ø29

6
85
450

83 ±3 58 ±0,1
125 ±3

 "V"
"A" 

Type Type
Installation arrangement without attachments without guard grille
A6E 360-AE08 -01 S6E 360-AE08 -01 "V"
97 A6E 360-AE08 -02 — "A"

 "V"
Ø370

"A" 

97

142
17
21
4,5

 "V"
c2 ±5
With guard grille for short nozzle

6,5
15,5
400
Type

S6E 360-AE08 -01


"V"
c2
134.0

143
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
K series, Ø 360

– Material: Guard grille: Steel, phosphated and coated in black plastic


Blades: PA plastic, black
Rotor: Coated in black
– Number of blades: 4
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

1~ 230 50 2275 1320 115 0.54 3.0 /400 55 55 -25 to +40


*4E 360 M4E 068-DF A
1~ 230 60 2440 1430 145 0.64 3.0 /400 57 40 -25 to +40 2.1 A1)
1~ 230 50 1850 850 65 0.29 2.5 /400 49 50 -25 to +55
*6E 360 M6E 068-DF B
1~ 230 60 2060 960 85 0.38 2.5 /400 52 40 -25 to +45 2.2 A1)
subject to alterations

n P1 I
Curves [rpm] [W] [A]

A 1 1310 116 0.55


[Pa]

[in H O]
2

A 2 1300 119 0.57

60 B 1 840 66 0.29
B 2 790 71 0.31
0,20

50

40 2 2
0,15

30
0,10

20 1 1
0,05

10
B A

0 250 500 750 1000 1250 [CFM]

400 800 1200 1600 2000 [m3/h]

50 Hz 60 Hz

144
information
General
AC axial fans
– Motor protection: TOP wired internally
– Cable exit: Axial
– Protection class: I
– Product conforming to standards: EN 60335-1, CE

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A" 
Without With guard grille
attachments for short nozzle

EC axial fans
"V" A4E 360-AC20 -05 S4E 360-EC20 -05
"A" A4E 360-AC20 -06 —
"V" A6E 360-AA08 -05 S6E 360-EA08 -05
"A" A6E 360-AA08 -06 —

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

145
Drawings Guard grille Terminal box Capacitor Electr. connections
p. 146 f. p. 366 p. 381 p. 382 f. p. 416 f.
AC axial fans
K series, Ø 360, drawings of directions of air flow "V" and "A"

Type
Without attachments c1 h
A4E 360-AC20 -05 "V" 8.0 84.0
- 0 + Depth of screw
A4E 360-AC20 -06 "A" -8.0 84.0
max. 5 mm
c1±3 A6E 360-AA08 -05 "V" -11.0 103.0
A6E 360-AA08 -06 "A" -8.0 103.0
Brass lead tips
2,5 83 ±3 M4
Ø360 ±2

4x90˚
Ø29

Ø92

27,5

6
85
450

h ±3 58

 "V"
"A" 

Type Type
Installation arrangement without attachments without guard grille l
A4E 360-AC20 -05 S4E 360-EC20 -05 "V" 43.0
l A4E 360-AC20 -06 — "A" 43.0
A6E 360-AA08 -05 S6E 360-EA08 -05 "V" 65.0
 "V" A6E 360-AA08 -06 — "A" 65.0
Ø370

"A" 

146
24

4
5

 "V"
c2±5
With guard grille for short nozzle

6,6
16,6
400
Type

S6E 360-EA08 -05


S4E 360-EC20 -05
"V"
"V"
c2

65.0
88.0

147
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
K series, Ø 450

– Material: Guard grille: Steel, phosphated and coated in black plastic


Blades: PA plastic, black
Rotor: Coated in black
– Number of blades: 3
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

1~ 230 50 4565 890 140 0.62 4.0 /400 57 45 -25 to +45


*6E 450-AF M6E 074-EI A 3.7 A1)
1~ 230 50 4550 890 142 0.65 4.0 /400 57 45 -25 to +50
*6E 450-AG M6E 074-GA B
1~ 230 60 5050 990 190 0.84 4.0 /400 61 50 -25 to +40 4.2 A1)
subject to alterations

n P1 I
Curves [rpm] [W] [A]

A 1 890 147 0.65


[Pa]

[in H O]
2

A 2 870 155 0.68


B 1 880 151 0.68
0,20

50
B 2 860 160 0.71
B 2

40
0,15

30
0,10

20 1
0,05

A
10

0 1000 2000 [CFM]

1000 2000 3000 4000 [m3/h]

50 Hz 60 Hz

148
information
General
AC axial fans
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC

AC axial
S series
– Options: Terminal box

AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A" 
Without With guard grille
attachments for short nozzle

EC axial fans
"V" A6E 450-AF08 -01 S6E 450-AF08 -01
"A" A6E 450-AF08 -02 —
"V" A6E 450-AG05 -01 S6E 450-AG05 -01
"A" A6E 450-AG05 -02 —

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

149
Drawings Guard grille Terminal box Capacitor Electr. connections
p. 150 f. p. 366 p. 381 p. 382 f. p. 416 f.
AC axial fans
K series, Ø 450, drawings of directions of air flow "V" and "A"

Type
Without attachments a c1
A6E 450-AF08 -01 "V" 117.0 4.0
- 0 + Depth of screw
A6E 450-AF08 -02 "A" 117.0 -18.0
c1 ±2 max. 10 mm
A6E 450-AG05 -01 "V" 129.0 4.0
A6E 450-AG05 -02 "A" 129.0 -18.0

5 a±1 M6
Ø 446 ±1

4x90˚
Ø 102
Ø 75

37
20

60
6
85

90 ±0,2
144 ±2
Brass lead tips

 "V"
"A" 

Type Type
Installation arrangement without attachments without guard grille
A6E 450-AF08 -01 S6E 450-AF08 -01 "V"
110 A6E 450-AF08 -02 — "A"
10-40
A6E 450-AG05 -01 S6E 450-AG05 -01 "V"
A6E 450-AG05 -02 — "A"
 "V"
Ø460

"A" 

10-40
110

150
30
5
80

 "V"
c2 ±5
476
With guard grille for short nozzle

522
Type

S6E 450-AG05 -01


S6E 450-AF08 -01
"V"
"V"
c2

98.0
98.0

151
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
K series, Ø 450

– Material: Guard grille: Steel, phosphated and coated in black plastic


Blades: PA plastic, black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

1~ 230 50 4415 900 145 0.64 4.0 /400 61 45 -25 to +55


*6E 450 M6E 074-EI A 3.7 A1)
subject to alterations

n P1 I
Curves [rpm] [W] [A]

A 1 880 151 0.66


[Pa]

[in H O]
2

A 2 850 160 0.70


0,20

50

40 2
0,15

A
30
0,10

20 1
0,05

10

0 500 1000 1500 2000 2500 [CFM]

1000 2000 3000 4000 [m3/h]

152
information
General
AC axial fans
– Motor protection: TOP wired internally
– Cable exit: Lateral
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Options: Terminal box

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A" 
Without With guard grille
attachments for short nozzle

EC axial fans
"V" A6E 450-AN08 -01 S6E 450-BN08 -01
"A" A6E 450-AN08 -02 S6E 450-BN08 -02

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

153
Drawings Guard grille Terminal box Capacitor Electr. connections
p. 154 f. p. 366 p. 381 p. 382 f. p. 416 f.
AC axial fans
K series, Ø 450, drawings of directions of air flow "V" and "A"

Type
Without attachments c1
A6E 450-AN08 -01 "V" 8.0
- 0 + Depth of screw
A6E 450-AN08 -02 "A" 25.0
c1 ±2 max. 10 mm

5 122 ±1 M6
Ø446 ±2

4x90˚
Ø102
Ø 75
600

6
85

92 ±1 90 ±0,2
Brass lead tips

 "V"
"A" 

Type Type
Installation arrangement without attachments without guard grille
A6E 450-AN08 -01 S6E 450-BN08 -01 "V"
100 A6E 450-AN08 -02 S6E 450-BN08 -02 "A"

20
 "V"
Ø452

20
"A" 

100

154
30
5

 "V"
c2 ±5

"A" 
476
With guard grille for short nozzle

9
19
522
Type

S6E 450-BN08 -02


S6E 450-BN08 -01
"V"
"A"
c2

117.0
100.0

155
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
156
AC axial fans A series

AC axial fans, A series


Ø 200 - Ø 350

157
158

Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
A series, Ø 200

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

3~ 230/400 50 830 2800 53 0.26/0.15 — 67 140 -25 to +75


*2D 200 (1) M2D 068-CF A
3~ 230/400 60 940 3150 70 0.24/0.14 — 70 140 -25 to +75 1.7 C1)/C2)
1~ 230 50 740 2740 50 0.24 1.5 /400 65 200 -25 to +75
*2E 200 M2E 068-CA B
1~ 230 60 830 3120 61 0.28 1.5 /400 69 200 -25 to +75 1.4 A1)
3~ 230/400 50 390 1450 22 0.16/0.09 — 51 70 -25 to +60
*4D 200 (1) M4D 068-CF C
3~ 230/400 60 460 1730 21 0.12/0.07 — 55 100 -25 to +80 1.5 C1)/C2)
1~ 230 50 375 1380 40 0.30 — 52 60 -25 to +50
*4S 200 M4S 068-BF D
1~ 230 60 445 1630 34 0.24 — 53 80 -25 to +65 1.2 B)
subject to alterations (1) 230 VAC ∆ / 400 VAC Y

n P1 I
Curves [rpm] [W] [A]

2785 53 0.15
[Pa]

[in H O]

A 1
2

240 A 2 2770 55 0.15


B 1 2670 51 0.24
B 2 2670 50 0.24
0,8

200

160
0,6

120
0,4

2 2
80
B

A
0,2

40 1 1

0 100 200 300 400 [CFM]

200 400 600 [m3/h]

50 Hz 60 Hz

158
information
General
AC axial fans
– Motor protection: A C Without TOP, B D TOP wired internally
– Cable exit: A C D Lateral, B variable
– Protection class: I
– Product conforming to standards: EN 60335-1, B D also CE
– Approvals: B CCC

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille
attachments round nozzle for full nozzle

EC axial fans
"V" A2D 200-AA02 -01 W2D 200-CA02 -01 S2D 200-BA02 -01
"A" A2D 200-AA02 -02 W2D 200-CA02 -02 S2D 200-BA02 -02
"V" A2E 200-AF02 -01 W2E 200-CF02 -01 S2E 200-BF02 -01
"A" A2E 200-AF02 -02 W2E 200-CF02 -02 S2E 200-BF02 -02
"V" A4D 200-AA04 -01 W4D 200-CA04 -01 S4D 200-BA04 -01
"A" A4D 200-AA04 -02 W4D 200-CA04 -02 S4D 200-BA04 -02
"V" A4S 200-AA02 -01 W4S 200-CA02 -01 S4S 200-BA02 -01

EC axial
S series
"A" A4S 200-AA02 -02 W4S 200-CA02 -02 S4S 200-BA02 -02

Q-motor
n P1 I
Curves [rpm] [W] [A]

C 1 1460 24 0.09
[Pa]

[in H O]
2

ESM
C 2 1460 24 0.09
D 1 1375 40 0.30
0,4

100
D 2 1380 39 0.29
EC-SYSTEMS

80
0,3

C
60
0,2

Accessories

40

D
0,1

2 2

20
1
Technology

0 50 100 150 200 250 [CFM]

100 200 300 400 [m3/h]

50 Hz 60 Hz
Contacts

159
Drawings Guard grille Wall ring Terminal box Capacitor Electr. connections
p. 160 p. 365 p. 372 f. p. 381 p. 382 f. p. 416 f.
AC axial fans
A series, Ø 200, drawings of directions of air flow "V" and "A"

Type
Without attachments c
A2D 200-AA02 -01 "V" 21.0
2 73 ±3 Depth of screw
A2D 200-AA02 -02 "A" 21.0
max. 5 mm
58 A2E 200-AF02 -01 "V" 21.0
A2E 200-AF02 -02 "A" 21.0
Ø 27 ±0,1

A4D 200-AA04 -01 "V" 20.0

M4
A4D 200-AA04 -02 "A" 20.0
A4S 200-AA02 -01 "V" 20.0
Ø195-2
Ø92

A4S 200-AA02 -02 "A" 20.0


450 ±20

c ±3 33 ±3
Brass lead tips
 "V"
"A" 

Type
With full round nozzle
W2D 200-CA02 -01 "V"
9 80 W2D 200-CA02 -02 "A"
6 W2E 200-CF02 -01 "V"
1,25

W2E 200-CF02 -02 "A"


˚
60
6x

W4D 200-CA04 -01 "V"


W4D 200-CA04 -02 "A"
W4S 200-CA02 -01 "V"
250
15˚
Ø 280
Ø 200

W4S 200-CA02 -02 "A"


45˚

7
 "V"
"A" 

Type
With guard grille for full nozzle
S2D 200-BA02 -01 "V"
12,5 S2D 200-BA02 -02 "A"
4 73 ±3 4,5 S2E 200-BF02 -01 "V"
S2E 200-BF02 -02 "A"
S4D 200-BA04 -01 "V"
S4D 200-BA04 -02 "A"
S4S 200-BA02 -01 "V"
S4S 200-BA02 -02 "A"

245

 "V"
"A" 

160
161
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
A series, Ø 250

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

3~ 230/400 50 1685 2650 110 0.38/0.22 — 72 300 -25 to +70


*2D 250 (1) M2D 068-DF A
3~ 230/400 60 1845 2950 160 0.45/0.26 — 75 300 -25 to +40 2.2 C1)/C2)
1~ 230 50 1610 2550 115 0.51 4.0 /400 72 150 -25 to +55
*2E 250 M2E 068-DF B
1~ 230 60 1740 2750 165 0.74 4.0 /400 73 130 -25 to +50 2.2 A1)
3~ 230/400 50 890 1420 30 0.16/0.09 — 58 90 -25 to +75
*4D 250 (1) M4D 068-CF C
3~ 230/400 60 1035 1650 35 0.14/0.08 — 62 100 -25 to +75 1.6 C1)/C2)
1~ 230 50 870 1400 72 0.53 — 58 80 -25 to +40
*4S 250 M4S 068-CF D
1~ 230 60 1000 1620 67 0.46 — 62 100 -25 to +50 1.7 B)
subject to alterations (1) 230 VAC ∆ / 400 VAC Y

n P1 I
Curves [rpm] [W] [A]

2645 123 0.23


[Pa]

[in H O]

A 1
2

A 2 2615 131 0.24


B 1 2520 122 0.54
B 2 2480 126 0.55
300
A
1,0

200
0,5

100 2
B 2

1 1

0 250 500 750 1000 [CFM]

400 800 1200 1600 [m3/h]

50 Hz 60 Hz

162
information
General
AC axial fans
– Motor protection: A C Without TOP, B D TOP wired internally
– Cable exit: A C D Lateral, B variable
– Protection class: I
– Product conforming to standards: EN 60335-1, B D also CE
– Approvals: A B CCC

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille
attachments round nozzle for full nozzle

EC axial fans
"V" A2D 250-AA02 -01 W2D 250-CA02 -01 S2D 250-BA02 -01
"A" A2D 250-AA02 -02 W2D 250-CA02 -02 S2D 250-BA02 -02
"V" A2E 250-AE65 -01 W2E 250-CE65 -01 S2E 250-BE65 -01
"A" A2E 250-AE65 -02 W2E 250-CE65 -02 S2E 250-BE65 -02
"V" A4D 250-AA04 -01 W4D 250-CA04 -01 S4D 250-BA04 -01
"A" A4D 250-AA04 -02 W4D 250-CA04 -02 S4D 250-BA04 -02
"V" A4S 250-AA02 -01 W4S 250-CA02 -01 S4S 250-BA02 -01

EC axial
S series
"A" A4S 250-AA02 -02 W4S 250-CA02 -02 S4S 250-BA02 -02

Q-motor
n P1 I
Curves [rpm] [W] [A]

C 1 1420 32 0.09
[Pa]

[in H O]
2

ESM
C 2 1410 33 0.09
D 1 1400 70 0.52
0,4

100 D 2 1395 71 0.52

C
EC-SYSTEMS

80
0,3

60
0,2

Accessories

40

2
0,1

D
20
1
Technology

0 200 400 600 [CFM]

200 400 600 800 1000 [m3/h]

50 Hz 60 Hz
Contacts

163
Drawings Guard grille Wall ring Terminal box Capacitor Electr. connections
p. 164 p. 365 p. 372 f. p. 381 p. 382 f. p. 416 f.
AC axial fans
A series, Ø 250, drawings of directions of air flow "V" and "A"

Type
Without attachments a c
A2D 250-AA02 -01 "V" 83.0 27.0
2 a ±3 Depth of screw
A2D 250-AA02 -02 "A" 83.0 27.0
max. 5 mm
58 A2E 250-AE65 -01 "V" 83.0 27.0
A2E 250-AE65 -02 "A" 83.0 27.0
Ø 27 ±0,1

A4D 250-AA04 -01 "V" 73.0 19.0

M4
A4D 250-AA04 -02 "A" 73.0 19.0
A4S 250-AA02 -01 "V" 73.0 19.0
Ø250-2
Ø92

A4S 250-AA02 -02 "A" 73.0 19.0


450 ±20

c ±3 39 ±3
Brass lead tips
 "V"
"A" 

Type
With full round nozzle
W2D 250-CA02 -01 "V"
9 85 W2D 250-CA02 -02 "A"
6 W2E 250-CE65 -01 "V"
1,25

W2E 250-CE65 -02 "A"


˚
60
6x

W4D 250-CA04 -01 "V"


W4D 250-CA04 -02 "A"
W4S 250-CA02 -01 "V"
295
15˚
Ø 320
Ø 254

W4S 250-CA02 -02 "A"


45˚

7
 "V"
"A" 

Type
With guard grille for full nozzle a
S2D 250-BA02 -01 "V" 83.0
12,5 S2D 250-BA02 -02 "A" 83.0
4 a ±3 4,5 S2E 250-BE65 -01 "V" 83.0
S2E 250-BE65 -02 "A" 83.0
S4D 250-BA04 -01 "V" 73.0
S4D 250-BA04 -02 "A" 73.0
S4S 250-BA02 -01 "V" 73.0
S4S 250-BA02 -02 "A" 73.0

290

 "V"
"A" 

164
165
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
A series, Ø 300

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

3~ 230/400 50 2760 2650 180 0.54/0.31 — 76 150 -25 to +60


*2D 300 (1) M2D 068-EC A
3~ 230/400 60 2940 2800 270 0.71/0.41 — 77 100 -25 to +40 2.7 C1)/C2)
1~ 230 50 2440 2650 140 0.62 5.0 /400 75 150 -25 to +55
*2E 300 M2E 068-EC B
1~ 230 60 2700 2900 190 0.83 5.0 /400 78 150 -25 to +50 2.5 A1)
3~ 230/400 50 1740 1370 85 0.36/0.21 — 66 100 -25 to +55
*4D 300 (1) M4D 068-DF C
3~ 230/400 60 1910 1520 110 0.38/0.22 — 69 110 -25 to +40 2.3 C1)/C2)
1~ 230 50 1690 1350 95 0.44 3.0 /400 65 120 -25 to +45
*4E 300 M4E 068-DF D
1~ 230 60 1830 1450 105 0.47 2.0 /400 66 100 -25 to +40 2.3 A1)
1~ 230 50 1440 1380 94 0.67 — 62 75 -25 to +30
*4S 300 M4S 068-DF E
1~ 230 60 1600 1550 94 0.67 — 64 60 -25 to +40 2.1 B)
subject to alterations (1) 230 VAC ∆ / 400 VAC Y

n P1 I
Curves [rpm] [W] [A]

A 1 2610 190 0.32


[Pa]

[in H O]
2

A 2 2535 220 0.35


B 1 2600 149 0.66
160
B 2 2530 162 0.71
0,6

120
0,4

2 A

80
0,2

40 1 1

0 400 800 1200 [CFM]

600 1200 1800 2400 [m3/h]

50 Hz 60 Hz

166
information
General
AC axial fans
– Motor protection: A C Without TOP, B D E TOP wired internally
– Cable exit: A C E Lateral, B D variable
– Protection class: I
– Product conforming to standards: EN 60335-1, B D E also CE
– Approvals: A C CCC, B GOST

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille
attachments round nozzle for full nozzle

EC axial fans
"V" A2D 300-AD02 -01 W2D 300-CD02 -01 S2D 300-BD02 -01
"A" A2D 300-AD02 -02 W2D 300-CD02 -02 S2D 300-BD02 -02
"V" A2E 300-AC47 -01 W2E 300-CC47 -01 S2E 300-BC47 -01
"A" A2E 300-AC47 -02 W2E 300-CC47 -02 S2E 300-BC47 -02
"V" A4D 300-AA02 -01 W4D 300-CA02 -01 S4D 300-BA02 -01
"A" A4D 300-AA02 -02 W4D 300-CA02 -02 S4D 300-BA02 -02
"V" A4E 300-AA01 -01 W4E 300-CA01 -01 S4E 300-BA01 -01

EC axial
S series
"A" A4E 300-AA01 -02 W4E 300-CA01 -02 S4E 300-BA01 -02
"V" A4S 300-AA02 -01 W4S 300-CA02 -01 S4S 300-BA02 -01
"A" A4S 300-AA02 -02 W4S 300-CA02 -02 S4S 300-BA02 -02

Q-motor
n P1 I
Curves [rpm] [W] [A]

C 1 1360 86 0.21
[Pa]

[in H O]
2

ESM
C 2 1345 94 0.22

120 D 1 1345 96 0.43


D 2 1315 101 0.45
C E 1 1375 92 0.67
0,4

100
EC-SYSTEMS
E 2 1360 94 0.67

D
80
0,3

2 2
60
Accessories
0,2

40 2
0,1

E
20
Technology

1 11

0 250 500 750 1000 [CFM]

400 800 1200 1600 [m3/h]

50 Hz 60 Hz
Contacts

167
Drawings Guard grille Wall ring Terminal box Capacitor Electr. connections
p. 168 p. 365 p. 372 f. p. 381 p. 382 f. p. 416 f.
AC axial fans
A series, Ø 300, drawings of directions of air flow "V" and "A"

Type
Without attachments a b c
A2D 300-AD02 -01 "V" 101.0 30.0 32.0
2 a ±3 Depth of screw
A2D 300-AD02 -02 "A" 101.0 30.0 32.0
c ±3 b ±3 max. 5 mm
A2E 300-AC47 -01 "V" 98.0 20.0 30.0
58
A2E 300-AC47 -02 "A" 98.0 20.0 30.0
A4D 300-AA02 -01 "V" 83.0 56.0 20.0
Ø 27 ±0,1

A4D 300-AA02 -02 "A" 83.0 56.0 20.0


A4E 300-AA01 -01 "V" 83.0 56.0 20.0

M4
Ø 300 -2

A4E 300-AA01 -02 "A" 83.0 56.0 20.0


Ø 92

A4S 300-AA02 -01 "V" 83.0 30.0 20.0


450 ±20

A4S 300-AA02 -02 "A" 83.0 30.0 20.0

 "V"
"A" 
Brass lead tips

Type
With full round nozzle
W2D 300-CD02 -01 "V"
10 80 W2D 300-CD02 -02 "A"
11 W2E 300-CC47 -01 "V"
W2E 300-CC47 -02 "A"
˚
60

W4D 300-CA02 -01 "V"


6x

W4D 300-CA02 -02 "A"


380

W4E 300-CA01 -01 "V"


W4E 300-CA01 -02 "A"
15˚
Ø 326
Ø 397

W4S 300-CA02 -01 "V"


W4S 300-CA02 -02 "A"
45˚

9
 "V"
"A" 

Type
With guard grille for full nozzle h
S2D 300-BD02 -01 "V" 64.0
8 S2D 300-BD02 -02 "A" 64.0
4,5 4,5 S2E 300-BC47 -01 "V" 50.0
S2E 300-BC47 -02 "A" 37.0
S4D 300-BA02 -01 "V" 73.0
S4D 300-BA02 -02 "A" 73.0
S4E 300-BA01 -01 "V" 73.0
S4E 300-BA01 -02 "A" 73.0
S4S 300-BA02 -01 "V" 52.0
S4S 300-BA02 -02 "A" 52.0

h 360

 "V"
"A" 

168
169
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
A series, Ø 315

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

3~ 230/400 50 1990 1400 78 0.33/0.19 — 65 150 -25 to +80


*4D 315 (1) M4D 068-EC A
3~ 230/400 60 2260 1590 115 0.36/0.21 — 68 150 -25 to +60 2.8 C1)/C2)
1~ 230 50 1950 1400 120 0.53 5.0 /400 67 180 -25 to +50
*4E 315 M4E 068-EC B
1~ 230 60 2230 1610 135 0.60 4.0 /400 70 120 -25 to +45 2.8 A1)
subject to alterations (1) 230 VAC ∆ / 400 VAC Y

n P1 I
Curves [rpm] [W] [A]

A 1 1390 82 0.19
[Pa]

[in H O]
2

A 2 1370 95 0.20
B 1 1395 123 0.55
B B 2 1360 136 0.60
160
0,6

120
0,4

80 2
0,2

A
40

0 250 500 750 1000 1250 [CFM]

400 800 1200 1600 2000 [m3/h]

50 Hz 60 Hz

170
information
General
AC axial fans
– Motor protection: A Without TOP, B TOP wired internally
– Cable exit: Lateral
– Protection class: I
– Product conforming to standards: EN 60335-1, B also CE
– Approvals: CCC

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille
attachments round nozzle for full nozzle

EC axial fans
"V" A4D 315-AC20 -01 W4D 315-CC20 -01 S4D 315-BC20 -01
"A" A4D 315-AC20 -02 W4D 315-CC20 -02 S4D 315-BC20 -02
"V" A4E 315-AA05 -01 W4E 315-CA05 -01 S4E 315-BA05 -01
"A" A4E 315-AA05 -02 W4E 315-CA05 -02 S4E 315-BA05 -02

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

171
Drawings Guard grille Wall ring Terminal box Capacitor Electr. connections
p. 172 p. 365 p. 372 f. p. 381 p. 382 f. p. 416 f.
AC axial fans
A series, Ø 315, drawings of directions of air flow "V" and "A"

Type
Without attachments a
A4D 315-AC20 -01 "V" 101.0
2 a ±3 Depth of screw
A4D 315-AC20 -02 "A" 101.0
22 ±3 65±3 max. 5 mm
A4E 315-AA05 -01 "V" 92.0
58
A4E 315-AA05 -02 "A" 92.0
Ø 27 ±0,1

M4
Ø 312 -2
Ø 92
450 ±20

 "V"
"A" 
Brass lead tips

Type
With full round nozzle
W4D 315-CC20 -01 "V"
10 74 W4D 315-CC20 -02 "A"
11 W4E 315-CA05 -01 "V"
W4E 315-CA05 -02 "A"
˚
60
6x

380
15˚
Ø 347
Ø 397

45˚

9
 "V"
"A" 

Type
With guard grille for full nozzle
S4D 315-BC20 -01 "V"
8 S4D 315-BC20 -02 "A"
4,5 6,4 S4E 315-BA05 -01 "V"
S4E 315-BA05 -02 "A"

84 375

 "V"
"A" 

172
173
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
AC axial fans
A series, Ø 350

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 5
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Mass without
Current draw

attachments
Power input
Speed/rpm
Frequency

Capacitor
Air flow
Curve

Nominal data
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg p. 416 f.

3~ 230/400 50 2900 1420 145 0.68/0.39 — 69 150 -25 to +45


*4D 350 (1) M4D 068-EC A
3~ 230/400 60 3300 1620 190 0.62/0.36 — 72 150 -25 to +40 3.1 C1)/C2)
1~ 230 50 2850 1390 140 0.62 5.0 /400 68 120 -25 to +60
*4E 350 M4E 068-EC B
1~ 230 60 3190 1550 195 0.86 5.0 /400 70 90 -25 to +40 3.1 A1)
subject to alterations (1) 230 VAC ∆ / 400 VAC Y

n P1 I
Curves [rpm] [W] [A]

A 1 1405 154 0.39


[Pa]

[in H O]
2

A 2 1390 169 0.40


B 1 1375 147 0.65
160
B 2 1345 161 0.71
A
0,6

120
0,4

80 2 2
0,2

B
40

11

0 500 1000 1500 2000 [CFM]

1000 2000 3000 [m3/h]

50 Hz 60 Hz

174
information
General
AC axial fans
– Motor protection: A Without TOP, B TOP wired internally
– Cable exit: Lateral
– Protection class: I
– Product conforming to standards: EN 60335-1, B also CE

AC axial
S series
AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille
attachments round nozzle for full nozzle

EC axial fans
"V" A4D 350-AA06 -01 W4D 350-CA06 -01 S4D 350-BA06 -01
"A" A4D 350-AA06 -02 W4D 350-CA06 -02 S4D 350-BA06 -02
"V" A4E 350-AA06 -01 W4E 350-CA06 -01 S4E 350-BA06 -01
"A" A4E 350-AA06 -02 W4E 350-CA06 -02 S4E 350-BA06 -02

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

175
Drawings Guard grille Wall ring Terminal box Capacitor Electr. connections
p. 176 p. 365 p. 372 f. p. 381 p. 382 f. p. 416 f.
AC axial fans
A series, Ø 350, drawings of directions of air flow "V" and "A"

Type
Without attachments
A4D 350-AA06 -01 "V"
2 102 ±3 Depth of screw
A4D 350-AA06 -02 "A"
21±3 70±3 max. 5 mm
A4E 350-AA06 -01 "V"
58
A4E 350-AA06 -02 "A"
Ø 27 ±0,1

M4
Ø 353 -2
Ø 92
450 ±20

 "V"
"A" 
Brass lead tips

Type
With full round nozzle
W4D 350-CA06 -01 "V"
11 80 W4D 350-CA06 -02 "A"
12 W4E 350-CA06 -01 "V"
W4E 350-CA06 -02 "A"
˚
60
6x

442
15˚
Ø 390
Ø 460

45˚

9
 "V"
"A" 

Type
With guard grille for full nozzle
S4D 350-BA06 -01 "V"
11 S4D 350-BA06 -02 "A"
4,5 6,4 S4E 350-BA06 -01 "V"
S4E 350-BA06 -02 "A"

85 422

 "V"
"A" 

176
177
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
178
EC axial fans
EC diagonal fans
EC axial fans, EC diagonal fans

Ø 200 - Ø 250
Ø 180 - Ø 208

179
181
180

Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC diagonal fans
Ø 180

– Material: – Mode of operation: Continuous operation (S1)


Wall ring: Die-cast aluminium – Bearings: Maintenance-free ball bearings
Blades: Plastic PA – Technical features: Control input 0-10 VDC /
Rotor: Galvanized PWM, tach output, polarity and locked rotor
– Number of blades: 5 protection, soft start
– Direction of air flow: "V", exhaust over – EMC:
struts Interference emission acc. to EN 61000-6-3
– Direction of rotation: Counter-clockwise, Interference immunity acc. to EN 61000-6-2
seen on rotor – Cable exit: Lateral
– Type of protection: IP 20 – Protection class: I
– Insulation class: "B" – Product conforming to standard: EN 60950-1
– Mounting position: Any – Approvals: UL, CSA;
– Condensate discharges: None A (48 VDC) with CCC

Max. operative range


Sound pressure level

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Power input
Speed/rpm
Air flow
Curve

Mass
Nominal data
Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C kg

W1G180-AB31 -01 M1G 074-BF A 24 16-28 900 4550 93 4.30 68 — -25 to +60 1.8
W1G180-AB47 -01 M1G 074-BF A 48 36-57 925 4600 100 2.30 69 — -25 to +60 1.8
subject to alterations

n P1 LpA tL n P1 LpA tL


[rpm] [W] [dB(A)] [%] [rpm] [W] [dB(A)] [%]
70 ±0,2
400 +20 2,5 A 1’ 5180 133 71 — A 3 4340 112 66 67
4970 141 70 70 4550 105 67 55
0

A 2’ A 4
22

6
08
Ø2

A 3’ 4760 146 68 67 A 5 3920 60 66 —


A 4’ 5010 140 69 55 A 6 3790 64 65 70
A 1 4600 100 69 — A 7 3660 68 63 67
4500 106 68 70 3790 63 63 55
147,1)

A 2 A 8
Ø169,7±1
Ø200 ±1

Curves (established at 48 VDC)


(

C
[Pa]

[in H O]

A
C
2

800
45˚
3,0

90˚ "V"  700

Section C-C Red = +


Blue = – 600
Ø4,3 ±0,15

Ø4,3 ±0,15

Yellow = PWM/Lin control input UR


White = Tach output
2,0

500

12 ±0,3 12 ±0,3 400


UN 4'

300 4
3'
1,0

3
8
200
7
2'
100 2
6

5 1 1'
0 200 400 600 [CFM]

200 400 600 800 1000 [m3/h]

180
Guard grille
p. 366
information
General
EC axial fans
Ø 200

AC axial fans
– Material: – Mode of operation: Continuous operation (S1)
Wall ring: Die-cast aluminium – Bearings: Maintenance-free ball bearings
Blades: Sheet steel, coated in black – Technical features: Control input 0-10 VDC /
Rotor: Coated in black PWM, tach output, polarity and locked rotor
– Number of blades: 9 protection

AC axial
S series
– Direction of air flow: "V", exhaust over – EMC:
struts Interference emission acc. to EN 61000-6-3
– Direction of rotation: Counter-clockwise, Interference immunity acc. to EN 61000-6-2
seen on rotor – Connection leads: Terminal strip
– Type of protection: IP 42 – Protection class: I
– Insulation class: "B" – Product conforming to standard: EN 60950-1

AC axial
K series
– Mounting position: Any – Approvals: UL, CSA;
– Condensate discharges: None B (48 VDC) with CCC

Max. operative range


Sound pressure level

Perm. amb. temp.


Nominal voltage

AC axial
Voltage range

A series
Current draw
Power input
Speed/rpm
Air flow
Curve

Mass
Nominal data
Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C kg

EC axial fans
W1G200-HH77 -52 M1G 074-BF B 24 16-28 1090 2950 55 2.60 60 — -25 to +60 2.1
W1G200-HH01 -52 M1G 074-BF B 48 36-57 1005 2750 45 1.10 60 — -25 to +60 2.1
subject to alterations

80 ±0,3

EC axial
S series
n P1 LpA tL n P1 LpA tL
[rpm] [W] [dB(A)] [%] [rpm] [W] [dB(A)] [%] 7
B 1’ 2300 73 63 — B 3 2800 61 61 64 2,6
B 2’ 2970 77 62 67 B 4 2780 63 64 54
B 3’ 3100 80 63 64 B 5 2270 27 55 —
22
5

B 4’ 2970 80 66 54 B 6 2230 28 54 67

Q-motor
B 1 2950 55 60 — B 7 2170 29 54 64
B 2 2890 58 60 67 B 8 2130 30 57 54
12

Curves (established at 24 VDC)


[Pa]

[in H O]

B PE (1)(2) – +
2

ESM
Ø4,5 +0,2
1,0

240
4
240
EC-SYSTEMS
0,8

200 260 "V" 

160 (1) Control input


(2) Tach output
0,6

UR

UN
Accessories

120 4'
0,4

4 3'

80 3

8
0,2

7 2'
40 2
Technology

5 1 1'
0 200 400 600 [CFM]

200 400 600 800 1000 [m3/h]


Contacts

181
Guard grille
p. 369
EC diagonal fans
Ø 208

– Material: – Mode of operation: Continuous operation (S1)


Wall ring: Die-cast aluminium – Bearings: Maintenance-free ball bearings
Blades: Plastic PA – Technical features: Control input 0-10 VDC /
Rotor: Galvanized PWM, tach output, polarity and locked rotor
– Number of blades: 5 protection
– Direction of air flow: "V", exhaust over – EMC:
struts Interference emission acc. to EN 61000-6-3
– Direction of rotation: Counter-clockwise, Interference immunity acc. to EN 61000-6-2
seen on rotor – Connection leads: Terminal strip
– Type of protection: IP 20 – Protection class: I
– Insulation class: "B" – Product conforming to standard: EN 60950-1
– Mounting position: Any – Approvals: VDE, UL, CSA;
– Condensate discharges: None A (48 VDC) with CCC

Max. operative range


Sound pressure level

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Power input
Speed/rpm
Air flow
Curve

Mass
Nominal data
Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C kg

W1G208-BA35 -52 M1G 074-BF A 24 16-28 1050 3500 96 4.40 74 — -25 to +72 2.3
W1G208-BA73 -52 M1G 074-BF A 48 36-57 1050 3500 96 2.26 74 — -25 to +72 2.3
subject to alterations

n P1 LpA tL n P1 LpA tL


[rpm] [W] [dB(A)] [%] [rpm] [W] [dB(A)] [%]
A 1’ 3740 116 75 — A 3 3250 100 72 53
A 2’ 3500 118 74 52 A 4 3330 99 73 48
A 3’ 3450 119 73 53 A 5 2960 58 70 —
A 4’ 3530 118 75 48 A 6 2830 63 69 52
A 1 3500 96 74 — A 7 2780 64 68 53
A 2 3300 99 72 52 A 8 2840 62 70 48

Curves
[Pa]

[in H O]

A
2

300
UR
"V" 
1,00

250
4'

Section C-C Red = + UN


Blue = – 4
Yellow = PWM/Lin control input
200 3'
Ø4,5
Ø4,5

0,75

White = Tach output


3

8
150
2'
10 ±0,3 10 ±0,3 7 2
0,50

100
6
0,25

50

5 1 1'
0 200 400 600 [CFM]

200 400 600 800 1000 [m3/h]

182
Guard grille
p. 367
information
General
EC axial fans
Ø 250

AC axial fans
– Material: – Mode of operation: Continuous operation (S1)
Wall ring: Die-cast aluminium – Bearings: Maintenance-free ball bearings
Blades: Sheet steel, coated in black – Technical features: Control input 0-10 VDC /
Rotor: Coated in black PWM, tach output, polarity and locked rotor
– Number of blades: 7 protection

AC axial
S series
– Direction of air flow: "V", exhaust over – EMC:
struts Interference emission acc. to EN 61000-6-3
– Direction of rotation: Counter-clockwise, Interference immunity acc. to EN 61000-6-2
seen on rotor – Connection leads: Terminal strip
– Type of protection: IP 42 – Protection class: I
– Insulation class: "B" – Product conforming to standard: EN 60950-1

AC axial
K series
– Mounting position: Any – Approvals: VDE, UL, CSA;
– Condensate discharges: None B (48 VDC) with CCC

Max. operative range


Sound pressure level

Perm. amb. temp.


Nominal voltage

AC axial
Voltage range

A series
Current draw
Power input
Speed/rpm
Air flow
Curve

Mass
Nominal data
Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C kg

EC axial fans
W1G250-HH37 -52 M1G 074-BF B 24 16-28 1920 2750 105 5.00 70 — -25 to +60 2.5
W1G250-HH67 -52 M1G 074-BF B 48 36-57 1920 2750 105 2.60 70 — -25 to +60 2.5
subject to alterations

80 ±0,3

EC axial
S series
n P1 LpA tL n P1 LpA tL
[rpm] [W] [dB(A)] [%] [rpm] [W] [dB(A)] [%] 7
B 1’ 2920 129 71 — B 3 2520 111 69 60 2,6
B 2’ 2800 132 72 63 B 4 2440 114 70 45
B 3’ 2680 135 71 60 B 5 2610 73 66 —
28
0

B 4’ 2600 139 72 45 B 6 2320 75 67 63

Q-motor
B 1 2750 105 70 — B 7 2230 78 67 60
B 2 2630 110 69 63 B 8 2170 80 68 45
12

Curves
[Pa]

[in H O]

B PE (1)(2) – +
2

ESM
240
Ø5,4 +0,2
0,8

200 4
UR 295
EC-SYSTEMS

320 "V" 
160
0,6

(1) Control input


4'
(2) Tach output
UN
120 4
Accessories
0,4

8 3'

80 3

7
0,2

2'
40 2
6
Technology

5 1 1'
0 400 800 [CFM]

400 800 1200 1600 [m3/h]


Contacts

183
Guard grille
p. 369
184
EC axial fans S series

EC axial fans, S series, 24 / 48 VDC

EC axial fans, S series, mains-powered


Ø 250 - Ø 990
Ø 200 - Ø 300
186

185
198

Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans 24 /48 VDC
S series, Ø 200

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 9
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Voltage range

Mass without
Current draw

attachments
Power input
Speed/rpm
Air flow
Curve

Nominal data
Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C kg p. 420

*1G 200 M1G 074-BF A 24 16-28 1090 2950 55 2.60 60 — -25 to +60 1.5 G)

*1G 200 M1G 074-BF A 48 36-57 1005 2750 45 1.10 60 — -25 to +60 1.5 G)
subject to alterations

n P1 LpA tL
Curves (established at 24 VDC) [rpm] [W] [dB(A)] [%]

A 1’ 2300 73 63 —
[Pa]

[in H O]

A
2

A 2’ 2970 77 62 67
A 3’ 3100 80 63 64
1,0

A 4’ 2970 80 66 54
240
A 1 2950 55 60 —
A 2 2890 58 60 67
0,8

200 A 3 2800 61 61 64
A 4 2780 63 64 54

160 A 5 2270 27 55 —
0,6

UR A 6 2230 28 54 67
UN A 7 2170 29 54 64
120 4' A 8 2130 30 57 54
0,4

4 3'

80 3

8
0,2

7 2'
40 2

5 1 1'
0 200 400 600 [CFM]

200 400 600 800 1000 [m3/h]

186
information
General
AC axial fans
– Technical features: • Tach output
• Control input 0-10 VDC / PWM • Polarity and locked rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable

AC axial
S series
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA

AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle (1) for full nozzle for short nozzle

EC axial fans
"V" A1G 200-AH77 -52 W1G 200-CH77 -52 S1G 200-BH77 -52 S1G 200-AH77 -52
"A" A1G 200-AI77 -52 W1G 200-CI77 -52 S1G 200-BI77 -52 S1G 200-AI77 -52
"V" A1G 200-AH01 -52 W1G 200-CH01 -52 S1G 200-BH01 -52 S1G 200-AH01 -52
"A" A1G 200-AI01 -52 W1G 200-CI01 -52 S1G 200-BI01 -52 S1G 200-AI01 -52
(1) Increased noise levels in "V" direction of air flow

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

187
Drawings Guard grille Wall ring Electr. connection
p. 188 f. p. 362 f. p. 372 f. p. 420
EC axial fans 24 /48 VDC
S series, Ø 200, drawings of directions of air flow "V" and "A"

Type
Without attachments
A1G 200-AH77 -52 "V"
Depth of screw
A1G 200-AI77 -52 "A"
max. 6 mm
17±5 A1G 200-AH01 -52 "V"
35 ±3 M4 A1G 200-AI01 -52 "A"

15
0,
±
58
Brass lead tips
Ø197-2
Ø92

32,7
6
85
450 +20
65 ±1

 "V"
"A" 

Type
With full round nozzle
W1G 200-CH77 -52 "V"
9 80 15˚ W1G 200-CI77 -52 "A"
5 W1G 200-CH01 -52 "V"
˚

W1G 200-CI01 -52 "A"


60
6x 7
1,25
Ø200
Ø280

250

 "V"
"A" 

Type
With guard grille for full nozzle
S1G 200-BH77 -52 "V"
S1G 200-BI77 -52 "A"
S1G 200-BH01 -52 "V"
3,9 4,6
S1G 200-BI01 -52 "A"
245

 "V"
"A" 

188
13 ±5

46

 "V"
"A" 
3,9
23
With guard grille for short nozzle

6,5

260
S1G
S1G
S1G
S1G
Type

200-AI01
200-AI77
200-AH01
200-AH77

-52
-52
-52
-52

"V"
"V"

"A"
"A"

189
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans 24 /48 VDC
S series, Ø 250

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 7 for direction of air flow "V", 9 for direction of air flow "A"
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Voltage range

Mass without
Current draw

attachments
Power input
Speed/rpm
Air flow
Curve

Nominal data
Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C kg p. 420

*1G 250 M1G 074-BF A 24 16-28 1920 2750 105 5.00 70 — -25 to +60 1.6 G)

*1G 250 M1G 074-BF A 48 36-57 1920 2750 105 2.60 70 — -25 to +60 1.6 G)
subject to alterations

n P1 LpA tL
Curves [rpm] [W] [dB(A)] [%]

A 1’ 2920 129 71 —
[Pa]

[in H O]

A
2

240 A 2’ 2800 132 72 63


A 3’ 2680 135 71 60
A 4’ 2600 139 73 45
0,8

200 A 1 2750 105 70 —


UR
A 2 2630 110 69 63
A 3 2520 111 69 60
160 A 4 2440 114 71 45
0,6

4'
A 5 2610 73 66 —
UN A 6 2320 75 67 63
120 4
A 7 2230 78 67 60
2170 80 68 45
0,4

A 8
8 3'

80 3

7
0,2

2'
40 2
6

5 1 1'
0 400 800 [CFM]

400 800 1200 1600 [m3/h]

190
information
General
AC axial fans
– Technical features: • Tach output
• Control input 0-10 VDC / PWM • Polarity and locked rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable

AC axial
S series
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA

AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle (1) for full nozzle for short nozzle

EC axial fans
"V" A1G 250-AH37 -52 W1G 250-CH37 -52 S1G 250-BH37 -52 S1G 250-AH37 -52
"A" A1G 250-AI37 -52 W1G 250-CI37 -52 S1G 250-BI37 -52 S1G 250-AI37 -52
"V" A1G 250-AH67 -52 W1G 250-CH67 -52 S1G 250-BH67 -52 S1G 250-AH67 -52
"A" A1G 250-AI67 -52 W1G 250-CI67 -52 S1G 250-BI67 -52 S1G 250-AI67 -52
(1) Increased noise levels in "V" direction of air flow

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

191
Drawings Guard grille Wall ring Electr. connection
p. 192 f. p. 362 f. p. 372 f. p. 420
EC axial fans 24 /48 VDC
S series, Ø 250, drawings of directions of air flow "V" and "A"

Type
Without attachments
A1G 250-AH37 -52 "V"
Depth of screw
A1G 250-AI37 -52 "A"
max. 6 mm
21±5 A1G 250-AH67 -52 "V"
35 ±3 M4 A1G 250-AI67 -52 "A"

5
,1
±0
58
Brass lead tips
Ø251 +1-2
Ø92

32,7
6
85
450 +20
65 ±1

 "V"
"A" 

Type
With full round nozzle
W1G 250-CH37 -52 "V"
9 87 15˚ W1G 250-CI37 -52 "A"
6 W1G 250-CH67 -52 "V"
˚

W1G 250-CI67 -52 "A"


60
6x 7
1,25
Ø257
Ø320

295

 "V"
"A" 

Type
With guard grille for full nozzle
S1G 250-BH37 -52 "V"
S1G 250-BI37 -52 "A"
S1G 250-BH67 -52 "V"
3,9 4,6
S1G 250-BI67 -52 "A"
290

 "V"
"A" 

192
18 ±5

45

 "V"
"A" 
3,9
27
With guard grille for short nozzle

6,5

300
S1G
S1G
S1G
S1G
Type

250-AI67
250-AI37
250-AH67
250-AH37

-52
-52
-52
-52

"V"
"V"

"A"
"A"

193
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans 24 /48 VDC
S series, Ø 300

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 7
– Direction of rotation: Direction of air flow "V" counter-clockwise, direction of air flow "A"
clockwise, seen on rotor
– Type of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range


Sound pressure level

Perm. amb. temp.

Electr. connection
Nominal voltage

Voltage range

Mass without
Current draw

attachments
Power input
Speed/rpm
Air flow
Curve

Nominal data
Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C kg p. 420

*1G 300 M1G 074-CF A 24 16-28 2450 1800 90 4.00 65 — -25 to +60 2.2 G)

*1G 300 M1G 074-CF A 48 36-57 2450 1800 90 2.00 65 — -25 to +60 2.2 G)
subject to alterations

n P1 LpA tL
Curves [rpm] [W] [dB(A)] [%]

A 1’ 1940 108 67 —
[Pa]

[in H O]

A
2

A 2’ 1850 111 66 71
A 3’ 1790 113 66 71
A 4’ 1720 116 66 60
160
A 1 1800 90 65 —
0,6

A 2 1720 89 65 71
UR A 3 1670 91 65 71
120 A 4 1600 93 64 60
A 5 1480 49 61 —
4'
0,4

A 6 1440 52 62 71
UN 4
A 7 1400 55 61 71
80 A 8 1350 58 59 60
8 3'
3
0,2

40 7
2'
2

5 1 1'
0 400 800 1200 [CFM]

600 1200 1800 2400 [m3/h]

194
information
General
AC axial fans
– Technical features: • Tach output
• Control input 0-10 VDC / PWM • Polarity and locked rotor protection
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
– Cable exit: Variable

AC axial
S series
– Protection class: I
– Product conforming to standard: EN 60950-1
– Approvals: UL, CSA

AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A1G 300-AE19 -54 W1G 300-CE19 -54 S1G 300-BE19 -54 S1G 300-AE19 -54
"A" A1G 300-AE19 -52 W1G 300-CE19 -52 S1G 300-BE19 -52 S1G 300-AE19 -52
"V" A1G 300-AE33 -54 W1G 300-CE33 -54 S1G 300-BE33 -54 S1G 300-AE33 -54
"A" A1G 300-AE33 -52 W1G 300-CE33 -52 S1G 300-BE33 -52 S1G 300-AE33 -52

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

195
Drawings Guard grille Wall ring Electr. connection
p. 196 f. p. 362 f. p. 372 f. p. 420
EC axial fans 24 /48 VDC
S series, Ø 300, drawings of directions of air flow "V" and "A"

Type
Without attachments c
A1G 300-AE19 -54 "V" 19.7
A1G 300-AE19 -52 "A" 19.2
A1G 300-AE33 -54 "V" 19.7
A1G 300-AE33 -52 "A" 19.2
58 ±0,15
c ±5 60 ±3 M4 Depth of screw
max. 6 mm
Brass lead tips

4x90˚
Ø300 -2
Ø92

6
31

85
450 +20
75 ±1

 "V"
"A" 

Type
With full round nozzle
W1G 300-CE19 -54 "V"
W1G 300-CE19 -52 "A"
80 W1G 300-CE33 -54 "V"
11 W1G 300-CE33 -52 "A"
˚
60
6x
9
15˚
Ø326
Ø397

380

 "V"
"A" 

Type
With guard grille for full nozzle
S1G 300-BE19 -54 "V"
S1G 300-BE19 -52 "A"
S1G 300-BE33 -54 "V"
3,9 4,6 S1G 300-BE33 -52 "A"
360

 "V"
"A" 

196
50

 "V"
"A" 
4,5
With guard grille for short nozzle

4,3

360
S1G
S1G
S1G
S1G
Type

300-AE33
300-AE33
300-AE19
300-AE19

-52
-54
-52
-54

"V"
"V"

"A"
"A"

197
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 250

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black
Blades: Sheet steel, coated in black
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 7 for direction of air flow "V", 9 for direction of air flow "A"
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom (rotor on top on request)
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Mass without
Max. current

attachments
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm W A Pa °C kg p. 423

*3G 250 M3G 074-CF A 1~ 100-130 50/60 2850 170 2.20 170 -25 to +60 2.4 J1)

*3G 250 M3G 074-CF B 1~ 200-277 50/60 3050 175 1.40 210 -25 to +60 2.4 J1)
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC

n P1 I LpA tL
Curves [rpm] [W] [A] [dB(A)] [%]

A 1 2850 162 1.80 71 —


[Pa]

[in H2O]

A
A 2 2820 158 1.90 71 84
200
A 3 2800 153 2.00 72 84
A 4 2770 144 2.00 74 79
A 5 2360 85 1.10 66 —
160 A 6 2360 91 1.20 66 77
4
0,6

A 7 2340 94 1.20 67 77
A 8 2310 95 1.20 68 70
120 A 9 1650 33 0.50 62 —
8
A 10 1650 35 0.50 56 68
0,4

3 A 11 1650 36 0.50 58 70
A 12 1650 37 0.50 59 68
80

12
0,2

2
40
6
11

10

9 5 1
0 250 500 750 1000 1250 [CFM]

400 800 1200 1600 2000 [m3/h]

198
information
General
AC axial fans
– Technical features: • Output 10 VDC max. 1.1 mA
• PFC (passive) • Tach output
• Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2

AC axial
S series
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for

AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle (2) for full nozzle for short nozzle

EC axial fans
"V" A3G 250-AC71 -01 W3G 250-CC71 -01 S3G 250-BC71 -01 S3G 250-AC71 -01
"A" A3G 250-AD71 -01 W3G 250-CD71 -01 S3G 250-BD71 -01 S3G 250-AD71 -01
"V" A3G 250-AC54 -01 W3G 250-CC54 -01 S3G 250-BC54 -01 S3G 250-AC54 -01
"A" A3G 250-AD54 -01 W3G 250-CD54 -01 S3G 250-BD54 -01 S3G 250-AD54 -01
(2) Increased noise levels in "V" direction of air flow

EC axial
S series
Q-motor
n P1 I LpA tL
Curves [rpm] [W] [A] [dB(A)] [%]

B 1 3050 170 1.30 72 —


[Pa]

[in H2O]

ESM
B 2 2970 169 1.30 73 89
200
B 3 2900 169 1.30 74 88
B 4 2820 168 1.30 75 86
4 B 5 2500 96 0.70 68 —
160
2410 94 0.70 68 86
EC-SYSTEMS
B 6
0,6

B 7 2360 94 0.70 69 86
B 8 2300 94 0.70 69 81
120 B 9 1740 37 0.30 57 —
8
3 B 10 1700 37 0.30 56 75
0,4

B 11 1660 37 0.30 58 75
Accessories

B 12 1610 37 0.30 59 72
80
7

12 2
0,2

40 6
11
Technology

10

9 5 1
0 250 500 750 1000 1250 [CFM]

400 800 1200 1600 2000 [m3/h]


Contacts

199
Drawings Guard grille Wall ring Electr. connection
p. 200 f. p. 362 f. p. 372 f. p. 423
EC axial fans mains-powered
S series, Ø 250, drawings of directions of air flow "V" and "A"

Type
Without attachments
A3G 250-AC71 -01 "V"
A3G 250-AD71 -01 "A"
(1)
105,2±1 M4 A3G 250-AC54 -01 "V"
(2)
21±3 M4 A3G 250-AD54 -01 "A"
(3)
32,5±0,5 M4
3±0,2
Ø133±0,3
Ø115,3

Ø92,1

4x90˚
+1
-2
Ø251

Ø9 8
Ø5
0
25
+2
0 45˚ Ø1
8 0
45 35±3
85
Core-end sleeve
 "V"
"A"  (1) Depth of screw max. 8 mm (pilot hole for self-tapping thread)
(2) Depth of screw max. 6 mm (pilot hole for self-tapping thread)
(3) Depth of screw 8-10 mm

Type
With full round nozzle
W3G 250-CC71 -01 "V"
W3G 250-CD71 -01 "A"
94,4±2 7
W3G 250-CC54 -01 "V"
86,5±2
W3G 250-CD54 -01 "A"
˚
60
6x
15˚
Ø320±1
Ø250±1

Ø257±1

5
29
6

 "V"
"A" 

Type
With guard grille for full nozzle
S3G 250-BC71 -01 "V"
S3G 250-BD71 -01 "A"
S3G 250-BC54 -01 "V"
33,25±1 55,25±3 4,2
S3G 250-BD54 -01 "A"
Ø290±1,5
Ø250±1

 "V"
"A" 

200
Ø281±1

71,25±2
38±1,5

 "V"
"A" 
5
Ø300±1,5
With guard grille for short nozzle

17,25±3
6,2
S3G
S3G
S3G
S3G
Type

250-AC54
250-AC71

250-AD54
250-AD71

-01
-01
-01
-01

"V"
"V"

"A"
"A"

201
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 300

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black
Blades: Sheet steel, coated in black
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" counter-clockwise, "A" clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom (rotor on top on request)
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Mass without
Max. current

attachments
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm W A Pa °C kg p. 423

*3G 300 M3G 074-CF A 1~ 100-130 50/60 1790 125 1.70 110 -25 to +60 2.7 J1)

*3G 300 M3G 074-CF B 1~ 200-277 50/60 1710 110 0.70 110 -25 to +60 2.7 J1)
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC

n P1 I LpA tL
Curves [rpm] [W] [A] [dB(A)] [%]

A 1 1790 92 1.20 64 —
[Pa]

[in H2O]

A
A 2 1770 98 1.30 64 62
A 3 1750 101 1.30 63 66
0,4

100 A 4 1720 106 1.40 62 67


A 5 1460 50 0.70 58 —
4
A 6 1430 53 0.70 58 61
80 A 7 1420 55 0.80 57 67
0,3

A 8 1400 58 0.80 56 65
A 9 1030 21 0.30 48 —
60 A 10 1030 22 0.30 49 52
8
3 A 11 1020 23 0.40 48 55
0,2

A 12 1010 24 0.40 46 59
40
7
12
2
0,1

20
11 6

10

9 5 1
0 250 500 750 1000 1250 [CFM]

400 800 1200 1600 2000 [m3/h]

202
information
General
AC axial fans
– Technical features: • Output 10 VDC max. 1.1 mA
• PFC (passive) • Tach output
• Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2

AC axial
S series
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for

AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A3G 300-AB77 -01 W3G 300-CB77 -01 S3G 300-BB77 -01 S3G 300-AB77 -01
"A" A3G 300-AB77 -02 W3G 300-CB77 -02 S3G 300-BB77 -02 S3G 300-AB77 -02
"V" A3G 300-AB56 -01 W3G 300-CB56 -01 S3G 300-BB56 -01 S3G 300-AB56 -01
"A" A3G 300-AB56 -02 W3G 300-CB56 -02 S3G 300-BB56 -02 S3G 300-AB56 -02

EC axial
S series
Q-motor
n P1 I LpA tL
Curves [rpm] [W] [A] [dB(A)] [%]

B 1 1710 76 0.60 62 —
[Pa]

[in H2O]

ESM
B 2 1680 81 0.60 62 64
B 3 1670 85 0.60 62 66
100
0,4

B 4 1650 89 0.70 60 69
B 5 1410 49 0.40 56 —
1390 52 0.40 57 57
EC-SYSTEMS
B 6
80 B 7 1345 54 0.50 56 61
4
0,3

B 8 1375 57 0.50 55 61
B 9 1000 21 0.20 47 —
60 B 10 990 22 0.20 48 54
8 B 11 990 23 0.20 46 58
0,2

Accessories

3 B 12 980 24 0.20 45 60
40

12
0,1

2
20
11 6
Technology

10

9 5 1
0 250 500 750 1000 1250 [CFM]

400 800 1200 1600 2000 [m3/h]


Contacts

203
Drawings Guard grille Wall ring Electr. connection
p. 204 f. p. 362 f. p. 372 f. p. 423
EC axial fans mains-powered
S series, Ø 300, drawings of directions of air flow "V" and "A"

Type
Without attachments c
A3G 300-AB77 -01 "V" 16.5

(1)
A3G 300-AB77 -02 "A" 16.0
105,2±1 M4 A3G 300-AB56 -01 "V" 16.5
(2)
c±3 M4
(3) A3G 300-AB56 -02 "A" 16.0
M4
32,5±0,5
3±0,2
Ø133±0,3
Ø115,3

Ø300-2
Ø92,1

4x90˚

Ø9 8
Ø5
Ø1 0
8 0 +2
0
25
45 45˚
85 60±3
Core-end sleeve
 "V"
"A"  (1) Depth of screw max. 8 mm (pilot hole for self-tapping thread)
(2) Depth of screw max. 6 mm (pilot hole for self-tapping thread)
(3) Depth of screw 8-10 mm

Type
With full round nozzle
W3G 300-CB77 -01 "V"
W3G 300-CB77 -02 "A"
W3G 300-CB56 -01 "V"
W3G 300-CB56 -02 "A"

 "V"
"A" 

Type
With guard grille for full nozzle
S3G 300-BB77 -01 "V"
S3G 300-BB77 -02 "A"
33,25±1 75,75±3 4,2 S3G 300-BB56 -01 "V"
S3G 300-BB56 -02 "A"
Ø360±1,5
Ø330±1

 "V"
"A" 

204
 "V"
"A" 
With guard grille for short nozzle

S3G
S3G
S3G
S3G
Type

300-AB56
300-AB56
300-AB77
300-AB77

-02
-01
-02
-01

"V"
"V"

"A"
"A"

205
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 315

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black
Blades: Sheet steel, coated in black
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" counter-clockwise, "A" clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom (rotor on top on request)
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Mass without
Max. current

attachments
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm W A Pa °C kg p. 423

*3G 315 M3G 074-CF A 1~ 100-130 50/60 1670 160 2.10 110 -25 to +60 2.9 J1)

*3G 315 M3G 074-CF B 1~ 200-277 50/60 1660 170 1.30 130 -25 to +60 2.9 J1)
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC

n P1 I LpA tL
Curves [rpm] [W] [A] [dB(A)] [%]

A 1 1670 109 1.40 63 —


[in H2O]
[Pa]

A
A 2 1660 118 1.50 62 53
A 3 1630 126 1.60 62 60
120 4
A 4 1610 138 1.80 60 55
A 5 1130 38 0.60 53 —
0,4

100 A 6 1120 42 0.60 52 48


A 7 1120 45 0.60 52 54
A 8 1110 49 0.70 50 50
3
80
A 9 560 8 0.10 32 —
0,3

A 10 560 9 0.20 31 25
60 A 11 560 9 0.20 31 33
8 A 12 560 10 0.20 29 30
0,2

40 2
7
0,1

20 6
12
11
10
9 5 1
0 400 800 1200 [CFM]

600 1200 1800 2400 [m3/h]

206
information
General
AC axial fans
– Technical features: • Output 10 VDC max. 1.1 mA
• PFC (passive) • Tach output
• Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2

AC axial
S series
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for

AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A3G 315-AA76 -01 W3G 315-CA76 -01 S3G 315-BA76 -01 S3G 315-AA76 -01
"A" A3G 315-AA76 -02 W3G 315-CA76 -02 S3G 315-BA76 -02 S3G 315-AA76 -02
"V" A3G 315-AA58 -01 W3G 315-CA58 -01 S3G 315-BA58 -01 S3G 315-AA58 -01
"A" A3G 315-AA58 -02 W3G 315-CA58 -02 S3G 315-BA58 -02 S3G 315-AA58 -02

EC axial
S series
Q-motor
n P1 I LpA tL
Curves [rpm] [W] [A] [dB(A)] [%]

B 1 1660 110 0.80 62 —


[Pa]

[in H2O]

ESM
B 2 1640 119 0.90 61 43
B 3 1625 125 0.90 62 52
120
B 4 1610 135 1.00 60 50
4 B 5 1250 50 1.00 55 —
0,4

100 1250 55 1.00 54 24


EC-SYSTEMS
B 6

B 7 1220 55 1.00 54 40
B 8 1170 57 1.00 52 43
80
B 9 640 11 0.40 35 —
0,3

3 B 10 630 12 0.40 34 17
60 B 11 630 12 0.50 34 31
Accessories

8 B 12 620 13 0.50 33 37
0,2

40 7
2
0,1

20 6
12
Technology

11
10
9 5 1
0 400 800 1200 [CFM]

600 1200 1800 2400 [m3/h]


Contacts

207
Drawings Guard grille Wall ring Electr. connection
p. 208 f. p. 362 f. p. 372 f. p. 423
EC axial fans mains-powered
S series, Ø 315, drawings of directions of air flow "V" and "A"

Type
Without attachments c
A3G 315-AA76 -01 "V" 6.0

(1)
A3G 315-AA76 -02 "A" -6.0
105,2±1 M4 A3G 315-AA58 -01 "V" 6.0
(2)
c±3 M4
(3) A3G 315-AA58 -02 "A" -6.0
32,5±0,5 M4

3±0,2
Ø133±0,3
Ø115,3

Ø312±2
Ø92,1

4x90˚

Ø9 58
Ø
Ø1 0
25
20
8 0+
45 45˚
85 85±3
Core-end sleeve
 "V"
"A"  (1) Depth of screw max. 8 mm (pilot hole for self-tapping thread)
(2) Depth of screw max. 6 mm (pilot hole for self-tapping thread)
(3) Depth of screw 8-10 mm

Type
With full round nozzle
W3G 315-CA76 -01 "V"
W3G 315-CA76 -02 "A"
W3G 315-CA58 -01 "V"
W3G 315-CA58 -02 "A"

 "V"
"A" 

Type
With guard grille for full nozzle s
S3G 315-BA76 -01 "V" 91.0
S3G 315-BA76 -02 "A" 79.0
S3G 315-BA58 -01 "V" 91.0
S3G 315-BA58 -02 "A" 79.0

 "V"
"A" 

208
 "V"
"A" 
With guard grille for short nozzle

S3G
S3G
S3G
S3G
Type

315-AA58
315-AA58
315-AA76
315-AA76

-02
-01
-02
-01

"V"
"V"

"A"
"A"
u

29.0
41.0
29.0
41.0

209
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 330

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black
Blades: Sheet steel, coated in black
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" counter-clockwise, "A" clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom (rotor on top on request)
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Mass without
Max. current

attachments
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm W A Pa °C kg p. 423

*3G 330 M3G 074-CF A 1~ 100-130 50/60 1660 170 2.20 120 -25 to +60 2.9 J1)

*3G 330 M3G 074-CF B 1~ 200-277 50/60 1630 170 1.30 120 -25 to +60 2.9 J1)
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC

n P1 I LpA tL
Curves [rpm] [W] [A] [dB(A)] [%]

A 1 1660 131 1.70 68 —


[in H2O]
[Pa]

A
A 2 1630 144 1.80 66 81
A 3 1610 147 1.90 64 78
120
A 4 1570 163 2.10 63 61
4 A 5 1350 72 1.00 64 —
100
0,4

A 6 1340 83 1.10 62 80
A 7 1330 87 1.20 60 74
A 8 1290 92 1.20 58 62
80
3 A 9 830 20 0.30 51 —
0,3

8
A 10 820 23 0.30 48 63
60 A 11 810 25 0.40 45 59
A 12 800 27 0.40 44 48
7
0,2

2
40

6
12
0,1

20 11

10

9 5 1
0 500 1000 1500 2000 [CFM]

1000 2000 3000 [m3/h]

210
information
General
AC axial fans
– Technical features: • Output 10 VDC max. 1.1 mA
• PFC (passive) • Tach output
• Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2

AC axial
S series
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for

AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A3G 330-AA76 -01 W3G 330-CA76 -01 S3G 330-BA76 -01 S3G 330-AA76 -01
"A" A3G 330-AA76 -02 W3G 330-CA76 -02 S3G 330-BA76 -02 S3G 330-AA76 -02
"V" A3G 330-AA58 -01 W3G 330-CA58 -01 S3G 330-BA58 -01 S3G 330-AA58 -01
"A" A3G 330-AA58 -02 W3G 330-CA58 -02 S3G 330-BA58 -02 S3G 330-AA58 -02

EC axial
S series
Q-motor
n P1 I LpA tL
Curves [rpm] [W] [A] [dB(A)] [%]

B 1 1630 130 0.95 68 —


[in H2O]
[Pa]

ESM
B 2 1600 139 1.00 65 70
B 3 1590 146 1.10 64 67
120
B 4 1580 151 1.10 63 60

4 B 5 1350 76 0.60 63 —
100
0,4

1330 82 0.60 61 72
EC-SYSTEMS
B 6

B 7 1330 86 0.65 60 69
B 8 1310 93 0.70 58 59
80
B 9 970 33 0.30 54 —
0,3

8 3
B 10 960 36 0.30 52 74
60 B 11 960 37 0.30 50 70
Accessories

B 12 950 40 0.30 49 60
0,2

40 2
12

6
11
0,1

20
Technology

10

9 5 1
0 500 1000 1500 2000 [CFM]

1000 2000 3000 [m3/h]


Contacts

211
Drawings Guard grille Wall ring Electr. connection
p. 212 f. p. 362 f. p. 372 f. p. 423
EC axial fans mains-powered
S series, Ø 330, drawings of directions of air flow "V" and "A"

Type
Without attachments c
A3G 330-AA76 -01 "V" 6.0

(1)
A3G 330-AA76 -02 "A" -7.0
105,2±1 M4 A3G 330-AA58 -01 "V" 6.0
(2)
c±3 M4
(3) A3G 330-AA58 -02 "A" -7.0
32,5±0,5 M4

3±0,2
Ø133±0,3
Ø115,3

Ø330±2
Ø92,1

4x90˚

Ø9 58
Ø
0
5
20
8 0+ 2
Ø1
45 45˚
85 87±3
Core-end sleeve
 "V"
"A"  (1) Depth of screw max. 8 mm (pilot hole for self-tapping thread)
(2) Depth of screw max. 6 mm (pilot hole for self-tapping thread)
(3) Depth of screw 8-10 mm

Type
With full round nozzle
W3G 330-CA76 -01 "V"
W3G 330-CA76 -02 "A"
W3G 330-CA58 -01 "V"
W3G 330-CA58 -02 "A"

 "V"
"A" 

Type
With guard grille for full nozzle s
S3G 330-BA76 -01 "V" 93.0
S3G 330-BA76 -02 "A" 80.0
S3G 330-BA58 -01 "V" 93.0
S3G 330-BA58 -02 "A" 80.0

 "V"
"A" 

212
 "V"
"A" 
With guard grille for short nozzle

S3G
S3G
S3G
S3G
Type

330-AA58
330-AA58
330-AA76
330-AA76

-02
-01
-02
-01

"V"
"V"

"A"
"A"
u

30.0
43.0
30.0
43.0

213
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 350

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black
Blades: Sheet steel, coated in black
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" counter-clockwise, "A" clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom (rotor on top on request)
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Mass without
Max. current

attachments
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm W A Pa °C kg p. 423

*3G 350 M3G 074-CF A 1~ 100-130 50/60 1600 170 2.20 100 -25 to +60 2.9 J1)

*3G 350 M3G 074-CF B 1~ 200-277 50/60 1540 170 1.30 100 -25 to +60 2.9 J1)
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC

n P1 I LpA tL
Curves [rpm] [W] [A] [dB(A)] [%]

A 1 1600 165 2.10 66 —


[in H2O]
[Pa]

A
A 2 1540 167 2.10 66 68
A 3 1490 167 2.10 64 72
120
A 4 1410 167 2.10 61 60

4 A 5 1300 91 1.20 62 —
0,4

100 A 6 1250 91 1.20 61 68


A 7 1210 92 1.20 59 70
A 8 1150 91 1.20 55 59
80
A 9 910 36 0.50 54 —
0,3

8 A 10 880 35 0.50 52 62
3
60 A 11 850 35 0.50 50 64
A 12 820 35 0.50 46 55
0,2

7
40
12
2
0,1

11 6
20

10

9 5 1
0 500 1000 1500 2000 [CFM]

1000 2000 3000 [m3/h]

214
information
General
AC axial fans
– Technical features: • Output 10 VDC max. 1.1 mA
• PFC (passive) • Tach output
• Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2

AC axial
S series
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 60950-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, EN 61800-5-1, EN 60950-1, CE
– Approvals: VDE, UL, CSA, CCC, GOST are applied for

AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A3G 350-AA76 -01 W3G 350-CA76 -01 S3G 350-BA76 -01 S3G 350-AA76 -01
"A" A3G 350-AA76 -02 W3G 350-CA76 -02 S3G 350-BA76 -02 S3G 350-AA76 -02
"V" A3G 350-AA58 -01 W3G 350-CA58 -01 S3G 350-BA58 -01 S3G 350-AA58 -01
"A" A3G 350-AA58 -02 W3G 350-CA58 -02 S3G 350-BA58 -02 S3G 350-AA58 -02

EC axial
S series
Q-motor
n P1 I LpA tL
Curves [rpm] [W] [A] [dB(A)] [%]

B 1 1540 150 1.20 67 —


[in H2O]
[Pa]

ESM
B 2 1520 162 1.20 66 62
B 3 1490 168 1.30 64 66
120
B 4 1430 167 1.20 61 61
4 B 5 1260 87 0.70 61 —
0,4

100 1240 91 0.70 60 60


EC-SYSTEMS
B 6

B 7 1200 90 0.70 58 64
B 8 1150 91 0.70 55 57
80
B 9 870 33 0.30 51 —
0,3

8 B 10 850 35 0.30 50 58
3
60 B 11 840 34 0.30 48 63
Accessories

B 12 810 34 0.30 45 57
0,2

40 7

12
2
0,1

20 11 6
Technology

10

9 5 1
0 500 1000 1500 2000 [CFM]

1000 2000 3000 [m3/h]


Contacts

215
Drawings Guard grille Wall ring Electr. connection
p. 216 f. p. 362 f. p. 372 f. p. 423
EC axial fans mains-powered
S series, Ø 350, drawings of directions of air flow "V" and "A"

Type
Without attachments c
A3G 350-AA76 -01 "V" 7.0

(1)
A3G 350-AA76 -02 "A" -12.0
105,2±1 M4 A3G 350-AA58 -01 "V" 7.0
(2)
c±3 M4
(3) A3G 350-AA58 -02 "A" -12.0
32,5±0,5 M4

3±0,2
Ø133±0,3
Ø115,3

Ø352±2
Ø92,1

4x90˚

Ø9 58
Ø
0
5
20
8 0+ 2
Ø1
45 45˚
85 92±3
Core-end sleeve
 "V"
"A"  (1) Depth of screw max. 8 mm (pilot hole for self-tapping thread)
(2) Depth of screw max. 6 mm (pilot hole for self-tapping thread)
(3) Depth of screw 8-10 mm

Type
With full round nozzle
W3G 350-CA76 -01 "V"
W3G 350-CA76 -02 "A"
W3G 350-CA58 -01 "V"
W3G 350-CA58 -02 "A"

 "V"
"A" 

Type
With guard grille for full nozzle s
S3G 350-BA76 -01 "V" 99.0
S3G 350-BA76 -02 "A" 80.0
S3G 350-BA58 -01 "V" 99.0
S3G 350-BA58 -02 "A" 80.0

 "V"
"A" 

216
 "V"
"A" 
With guard grille for short nozzle

S3G
S3G
S3G
S3G
Type

350-AA58
350-AA58
350-AA76
350-AA76

-02
-01
-02
-01

"V"
"V"

"A"
"A"
u

30.0
49.0
30.0
49.0

217
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 400

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black
Blades: Sheet steel, coated in black
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" counter-clockwise, "A" clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom (rotor on top on request)
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Mass without
Max. current

attachments
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm W A Pa °C kg p. 425

*3G 400 M3G 084-FA A 1~ 100-130 50/60 1620 350 4.20 165 -25 to +60 5.2 K1)

*3G 400 M3G 084-FA B 1~ 200-277 50/60 1690 390 2.50 180 -25 to +60 5.2 K1)
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC

n P1 I LpA tL
Curves [rpm] [W] [A] [dB(A)] [%]

A 1 1620 310 3.80 69 —


[Pa]

[in H O]

A
2

A 2 1590 332 4.00 68 66


175 A 3 1565 349 4.20 68 62
4 A 4 1550 350 4.20 68 54

150
0,5

125

100

75
0,25

2
50

25

1
0 1000 2000 3000 [CFM]

1000 2000 3000 4000 5000 [m3/h]

218
information
General
AC axial fans
– Technical features: • Output 10 VDC max. 1.1 mA
• PFC (passive) • Alarm relay
• Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2

AC axial
S series
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: B UL, CSA; A B VDE, CCC, GOST are applied for

AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A3G 400-AA37 -81 W3G 400-CA37 -81 S3G 400-KA37 -81 S3G 400-LA37 -81
"A" A3G 400-AA37 -82 W3G 400-CA37 -82 S3G 400-KA37 -82 S3G 400-LA37 -82
"V" A3G 400-AA22 -71 W3G 400-CA22 -71 S3G 400-KA22 -71 S3G 400-LA22 -71
"A" A3G 400-AA22 -72 W3G 400-CA22 -72 S3G 400-KA22 -72 S3G 400-LA22 -72

EC axial
S series
Q-motor
n P1 I LpA tL
Curves [rpm] [W] [A] [dB(A)] [%]

B 1 1690 340 2.10 75 —


[Pa]

[in H O]

B
2

ESM
B 2 1660 375 2.30 72 64
B 3 1640 380 2.40 70 61
B 4 1630 390 2.50 68 54
0,5

150 B 5 1300 162 1.00 68 —


1300 179 1.10 66 64
EC-SYSTEMS
3 B 6

B 7 1300 192 1.20 64 61


8 B 8 1300 203 1.20 63 54
B 9 1000 76 0.50 61 —
100 B 10 1000 91 0.60 60 64
7 2 B 11 1000 93 0.60 57 61
Accessories

B 12 1000 100 0.70 56 54


12
0,25

6
50 11

10
Technology

9 5 1
0 1000 2000 3000 [CFM]

1000 2000 3000 4000 5000 [m3/h]


Contacts

219
Drawings Guard grille Wall ring Electr. connection
p. 220 f. p. 362 ff. p. 372 f. p. 425
EC axial fans mains-powered
S series, Ø 400, drawings of directions of air flow "V" and "A"

Type
Without attachments
A3G 400-AA37 -81 "V"
Depth of screw 8-10 mm
A3G 400-AA37 -82 "A"
A3G 400-AA22 -71 "V"
A3G 400-AA22 -72 "A"

Core-end sleeve  "V"


"A" 

Type
With full round nozzle
W3G 400-CA37 -81 "V"
W3G 400-CA37 -82 "A"
W3G 400-CA22 -71 "V"
W3G 400-CA22 -72 "A"

 "V"
"A" 

Type
With guard grille for full nozzle
S3G 400-KA37 -81 "V"
S3G 400-KA37 -82 "A"
S3G 400-KA22 -71 "V"
S3G 400-KA22 -72 "A"

 "V"
"A" 

220
 "V"
"A" 
With guard grille for short nozzle

S3G
S3G
S3G
S3G
Type

400-LA22
400-LA22
400-LA37
400-LA37

-72
-71
-82
-81

"V"
"V"

"A"
"A"

221
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 450

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black
Blades: Sheet steel, coated in black
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" counter-clockwise, "A" clockwise, seen on rotor
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Shaft horizontal or rotor on bottom (rotor on top on request)
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Mass without
Max. current

attachments
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm W A Pa °C kg p. 425

*3G 450 M3G 084-FA A 1~ 100-130 50/60 1270 310 3.70 120 -25 to +60 5.5 K1)

*3G 450 M3G 084-FA B 1~ 200-277 50/60 1310 325 2.10 120 -25 to +60 5.5 K1)
subject to alterations (1) Nominal data in operating point with maximum load and 115 or 230 VAC

n P1 I LpA tL
Curves [rpm] [W] [A] [dB(A)] [%]

A 1 1270 267 3.30 69 —


[Pa]

[in H O]

A
2

A 2 1245 282 3.50 69 70


175 A 3 1230 300 3.70 67 66
A 4 1220 308 3.70 63 42

150
0,5

125
4

100

3
75
0,25

50
2

25

1
0 1000 2000 3000 [CFM]

1000 2000 3000 4000 5000 [m3/h]

222
information
General
AC axial fans
– Technical features: • Output 10 VDC max. 1.1 mA
• PFC (passive) • Alarm relay
• Control input 0-10 VDC / PWM • Over-temperature protected electronics / motor
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2

AC axial
S series
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 61800-5-1, CE
– Approvals: B UL, CSA; A B VDE, CCC, GOST are applied for

AC axial
K series
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"/ "A"   "V"/ "A" 
Without With full With guard grille With guard grille
attachments round nozzle for full nozzle for short nozzle

EC axial fans
"V" A3G 450-AA40 -81 W3G 450-CA40 -81 S3G 450-KA40 -81 S3G 450-LA40 -81
"A" A3G 450-AA40 -82 W3G 450-CA40 -82 S3G 450-KA40 -82 S3G 450-LA40 -82
"V" A3G 450-AA14 -71 W3G 450-CA14 -71 S3G 450-KA14 -71 S3G 450-LA14 -71
"A" A3G 450-AA14 -72 W3G 450-CA14 -72 S3G 450-KA14 -72 S3G 450-LA14 -72

EC axial
S series
Q-motor
n P1 I LpA tL
Curves [rpm] [W] [A] [dB(A)] [%]

B 1 1310 245 1.50 73 —


[Pa]

[in H O]

B
2

ESM
B 2 1290 262 1.70 72 70
200
B 3 1270 290 1.90 70 66
B 4 1240 325 2.10 66 42
B 5 1000 108 0.70 68 —
160
1000 122 0.80 67 70
EC-SYSTEMS
B 6
0,6

B 7 1000 140 0.90 65 66


B 8 1000 174 1.10 61 42
120 4 B 9 700 38 0.30 61 —
B 10 700 42 0.30 60 70
0,4

B 11 700 48 0.30 58 66
Accessories

3
B 12 700 60 0.40 56 42
80
8
0,2

7
40 12
2

6
Technology

11

10

9 5 1
0 1000 2000 3000 [CFM]

1000 2000 3000 4000 5000 [m3/h]


Contacts

223
Drawings Guard grille Wall ring Electr. connection
p. 224 f. p. 362 ff. p. 372 f. p. 425
EC axial fans mains-powered
S series, Ø 450, drawings of directions of air flow "V" and "A"

Type
Without attachments
A3G 450-AA40 -81 "V"
Depth of screw 8-10 mm
A3G 450-AA40 -82 "A"
A3G 450-AA14 -71 "V"
A3G 450-AA14 -72 "A"

Core-end sleeve
 "V"
"A" 

Type
With full round nozzle
W3G 450-CA40 -81 "V"
W3G 450-CA40 -82 "A"
W3G 450-CA14 -71 "V"
W3G 450-CA14 -72 "A"

 "V"
"A" 

Type
With guard grille for full nozzle
S3G 450-KA40 -81 "V"
S3G 450-KA40 -82 "A"
S3G 450-KA14 -71 "V"
S3G 450-KA14 -72 "A"

 "V"
"A" 

224
 "V"
"A" 
With guard grille for short nozzle

S3G
S3G
S3G
S3G
Type

450-LA14
450-LA14
450-LA40
450-LA40

-72
-71
-82
-81

"V"
"V"

"A"
"A"

225
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 500

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 427

*3G 500 M3G 112-GA A 1~ 200-277 50/60 1250 0.69 3.10 110 -25 to +60 L1)
subject to alterations (1) Nominal data in operating point with maximum load and 230 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

A 1 1260 0.61 2.80 74 —


[in H2O]
[Pa]

A
A 2 1260 0.67 3.00 76 62
200
A 3 1250 0.69 3.10 77 60
A 4 — — — — —
A 5 1020 0.41 1.90 80 —
160
A 6 1030 0.36 1.70 70 67
0,6

A 7 1020 0.37 1.70 71 67


A 8 1020 0.36 1.70 73 63
120 A 9 750 0.16 0.80 70 —
3 A 10 740 0.15 0.70 62 73
8
0,4

A 11 740 0.15 0.70 62 72


A 12 740 0.15 0.70 63 68
80
7

2
12
0,2

6
40 11

10

9 5 1
0 1000 2000 3000 4000 5000 6000 [CFM]

2000 4000 6000 8000 10000 [m3/h]

226
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage detection
• PFC (active) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST; CCC is applied for
Direction of air flow

AC axial
A series
 "V"  "V"  "V"  "V"
Without With full With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle

EC axial fans
"V" A3G 500-AE33 -11 W3G 500-CE33 -11 S3G 500-BE33 -11 S3G 500-AE33 -11

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

227
Drawings Electr. connection
p. 230 f. p. 427
EC axial fans mains-powered
S series, Ø 500

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 427

*3G 500 M3G 112-GA A 3~ 200-240 50/60 1450 1.04 3.40 195 -25 to +60 L2)

*3G 500 M3G 112-GA B 3~ 380-480 50/60 1450 1.04 1.70 195 -25 to +60 L2)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

A 1 1450 1.21 3.80 97 —


[in H2O]
[Pa]

A
A 2 1450 1.00 3.20 79 77
200
4 A 3 1450 1.05 3.40 81 68
A 4 1450 1.04 3.40 82 60
A 5 1220 0.70 2.40 87 —
160
A 6 1270 0.66 2.20 76 81
0,6

8
3
A 7 1260 0.67 2.40 77 73
A 8 1260 0.66 2.20 79 62
120 A 9 1080 0.47 1.80 83 —
12
7 A 10 1110 0.44 1.80 73 81
0,4

A 11 1110 0.46 1.80 74 72


11
A 12 1100 0.45 1.80 75 63
80 2

6
0,2

10
40

9 5 1
0 1000 2000 3000 4000 5000 6000 [CFM]

2000 4000 6000 8000 10000 [m3/h]

228
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST; CCC is applied for
Direction of air flow

AC axial
A series
 "V"  "V"  "V"  "V"
Without With full With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle

EC axial fans
"V" A3G 500-AE38 -06 W3G 500-CE38 -06 S3G 500-BE38 -06 S3G 500-AE38 -06

"V" A3G 500-AE33 -01 W3G 500-CE33 -01 S3G 500-BE33 -01 S3G 500-AE33 -01

EC axial
S series
Q-motor
n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

B 1 1450 1.21 1.90 97 —


[in H2O]
[Pa]

ESM
B 2 1450 1.00 1.60 79 77
200
4 B 3 1450 1.05 1.70 81 68
B 4 1450 1.04 1.70 82 60
B 5 1220 0.70 1.20 87 —
160
1270 0.66 1.10 76 81
EC-SYSTEMS
B 6
0,6

8
3
B 7 1260 0.67 1.20 77 73
B 8 1260 0.66 1.10 79 62
120 B 9 1080 0.47 0.90 83 —
12
7 B 10 1110 0.44 0.90 73 81
0,4

B 11 1110 0.46 0.90 74 72


Accessories

11
B 12 1100 0.45 0.90 75 63
80 2

6
0,2

10
40
Technology

9 5 1
0 1000 2000 3000 4000 5000 6000 [CFM]

2000 4000 6000 8000 10000 [m3/h]


Contacts

229
Drawings Electr. connection
p. 230 f. p. 427
EC axial fans mains-powered
S series, Ø 500, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
A3G 500-AE33 -11 8.7
A3G 500-AE38 -06 8.7
A3G 500-AE33 -01 8.7

Depth of screw
12-16 mm
Cable gland

 "V"

Type Mass
With full square nozzle [kg]
W3G 500-CE33 -11 16.2
W3G 500-CE38 -06 16.2
W3G 500-CE33 -01 16.2

 "V"

Type Mass
With guard grille for full nozzle [kg]
S3G 500-BE33 -11 11.2
S3G 500-BE38 -06 11.2
S3G 500-BE33 -01 11.2

 "V"

230
 "V"
With guard grille for short nozzle
Type

S3G 500-AE33 -01


S3G 500-AE38 -06
S3G 500-AE33 -11
[kg]

12.4
12.4
12.4
Mass

231
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 560

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 427

*3G 560 M3G 112-GA A 1~ 200-277 50/60 1160 0.79 3.50 155 -25 to +60 L1)
subject to alterations (1) Nominal data in operating point with maximum load and 230 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

A 1 1160 0.66 3.00 77 —


[in H2O]
[Pa]

A
A 2 1160 0.73 3.30 80 82
200
A 3 1150 0.77 3.40 80 74
A 4 1160 0.79 3.50 80 65
A 5 970 0.35 1.60 73 —
160 4 A 6 950 0.39 1.80 75 92
0,6

A 7 930 0.40 1.80 74 82


A 8 940 0.41 1.90 74 72
120 A 9 680 0.14 0.70 67 —
8 3
A 10 690 0.16 0.80 67 96
0,4

A 11 680 0.17 0.80 65 88


A 12 680 0.17 0.80 66 76
80
7

2
12
0,2

6
40 11

10

9 5 1
0 2000 4000 6000 [CFM]

2000 4000 6000 8000 10000 12000 [m3/h]

232
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage detection
• PFC (active) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST; CCC is applied for
Direction of air flow

AC axial
A series
 "V"  "V"  "V"  "V"
Without With full With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle

EC axial fans
"V" A3G 560-AE41 -11 W3G 560-CE41 -11 S3G 560-BE41 -11 S3G 560-AE41 -11

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

233
Drawings Electr. connection
p. 236 f. p. 427
EC axial fans mains-powered
S series, Ø 560

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 427

*3G 560 M3G 112-GA A 3~ 200-240 50/60 1260 0.97 3.20 180 -25 to +60 L2)

*3G 560 M3G 112-GA B 3~ 380-480 50/60 1260 0.97 1.60 180 -25 to +60 L2)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

A 1 1260 0.81 2.80 77 —


[in H2O]
[Pa]

A
A 2 1260 0.92 3.20 80 75
200
A 3 1260 0.96 3.20 81 65
4
A 4 1260 0.97 3.20 83 58
A 5 1080 0.50 2.00 73 —
160
A 6 1060 0.53 2.00 75 80
0,6

A 7 1050 0.54 2.00 76 71


A 8 1040 0.54 2.00 78 63
8 3
120 A 9 800 0.22 1.00 67 —
A 10 790 0.24 1.00 68 86
0,4

A 11 780 0.24 1.00 69 75


7
A 12 780 0.24 1.00 69 66
80
12 2

11 6
0,2

40
10

9 5 1
0 2000 4000 6000 [CFM]

2000 4000 6000 8000 10000 12000 [m3/h]

234
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST; CCC is applied for
Direction of air flow

AC axial
A series
 "V"  "V"  "V"  "V"
Without With full With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle

EC axial fans
"V" A3G 560-AE43 -06 W3G 560-CE43 -06 S3G 560-BE43 -06 S3G 560-AE43 -06

"V" A3G 560-AE32 -01 W3G 560-CE32 -01 S3G 560-BE32 -01 S3G 560-AE32 -01

EC axial
S series
Q-motor
n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

B 1 1260 0.81 1.40 77 —


[in H2O]
[Pa]

ESM
B 2 1260 0.92 1.60 80 75
200
B 3 1260 0.96 1.60 81 65
4
B 4 1260 0.97 1.60 83 58
B 5 1080 0.50 1.00 73 —
160
1060 0.53 1.00 75 80
EC-SYSTEMS
B 6
0,6

B 7 1050 0.54 1.00 76 71


B 8 1040 0.54 1.00 78 63
8 3
120 B 9 800 0.22 0.50 67 —
B 10 790 0.24 0.50 68 86
0,4

B 11 780 0.24 0.50 69 75


Accessories

7
B 12 780 0.24 0.50 69 66
80
12 2

11 6
0,2

40
10
Technology

9 5 1
0 2000 4000 6000 [CFM]

2000 4000 6000 8000 10000 12000 [m3/h]


Contacts

235
Drawings Electr. connection
p. 236 f. p. 427
EC axial fans mains-powered
S series, Ø 560, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
A3G 560-AE41 -11 8.9
A3G 560-AE43 -06 8.9
A3G 560-AE32 -01 8.9

Depth of screw
12-16 mm
Cable gland

 "V"

Type Mass
With full square nozzle [kg]
W3G 560-CE41 -11 18.0
W3G 560-CE43 -06 18.0
W3G 560-CE32 -01 18.0

 "V"

Type Mass
With guard grille for full nozzle [kg]
S3G 560-BE41 -11 11.9
S3G 560-BE43 -06 11.9
S3G 560-BE32 -01 11.9

 "V"

236
 "V"
With guard grille for short nozzle
Type

S3G 560-AE32 -01


S3G 560-AE43 -06
S3G 560-AE41 -11
[kg]

13.6
13.6
13.6
Mass

237
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 630

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 427

*3G 630 M3G 112-GA A 1~ 200-277 50/60 970 0.73 3.30 135 -25 to +60 L1)
subject to alterations (1) Nominal data in operating point with maximum load and 230 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

A 1 970 0.55 2.60 74 —


[in H2O]
[Pa]

A
A 2 970 0.66 3.00 76 88
160 A 3 960 0.69 3.20 77 79
0,6

A 4 970 0.73 3.30 79 68


A 5 750 0.25 1.20 68 —
4
A 6 750 0.30 1.40 70 92
120 A 7 750 0.32 1.50 71 83
A 8 750 0.33 1.60 72 70
0,4

3 A 9 540 0.11 0.70 61 —


A 10 540 0.13 0.70 63 92
80 8 A 11 540 0.14 0.60 63 85
A 12 540 0.14 0.70 63 71
2
7
0,2

12
40 6
11

10

9 5 1
0 2000 4000 6000 [CFM]

2000 4000 6000 8000 10000 12000 [m3/h]

238
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage detection
• PFC (active) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST; CCC is applied for
Direction of air flow

AC axial
A series
 "V"  "V"  "V"  "V"
Without With full With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle

EC axial fans
"V" A3G 630-AE37 -11 W3G 630-CE37 -11 S3G 630-BE37 -11 S3G 630-AE37 -11

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

239
Drawings Electr. connection
p. 242 f. p. 427
EC axial fans mains-powered
S series, Ø 630

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 427

*3G 630 M3G 112-GA A 3~ 200-240 50/60 1010 0.83 3.00 150 -25 to +60 L2)

*3G 630 M3G 112-GA B 3~ 380-480 50/60 1010 0.83 1.50 150 -25 to +60 L2)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

A 1 1010 0.62 2.20 75 —


[in H2O]
[Pa]

A
A 2 1010 0.74 2.60 77 87
160 A 3 1010 0.78 2.80 78 77
0,6

4 A 4 1010 0.83 3.00 79 65


A 5 920 0.45 1.80 73 —
A 6 900 0.51 2.00 75 92
120 A 7 880 0.49 1.80 75 83
3
8 A 8 860 0.51 2.00 76 68
0,4

A 9 680 0.20 0.80 66 —


7 A 10 680 0.22 1.00 67 49
80 A 11 660 0.22 1.00 67 91
2
A 12 650 0.23 1.00 68 74
12
6
0,2

11

40
10

9 5 1
0 2000 4000 6000 [CFM]

2000 4000 6000 8000 10000 12000 [m3/h]

240
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST; CCC is applied for
Direction of air flow

AC axial
A series
 "V"  "V"  "V"  "V"
Without With full With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle

EC axial fans
"V" A3G 630-AE42 -06 W3G 630-CE42 -06 S3G 630-BE42 -06 S3G 630-AE42 -06

"V" A3G 630-AE31 -01 W3G 630-CE31 -01 S3G 630-BE31 -01 S3G 630-AE31 -01

EC axial
S series
Q-motor
n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

B 1 1010 0.62 1.10 75 —


[in H2O]
[Pa]

ESM
B 2 1010 0.74 1.30 77 87
160 B 3 1010 0.78 1.40 78 77
0,6

4 B 4 1010 0.83 1.50 79 65


B 5 920 0.45 0.90 73 —
900 0.51 1.00 75 92
EC-SYSTEMS
B 6

120 B 7 880 0.49 0.90 75 83


3
8 B 8 860 0.51 1.00 76 68
0,4

B 9 680 0.20 0.40 66 —


7 B 10 680 0.22 0.50 67 49
80 B 11 660 0.22 0.50 67 91
Accessories

2
B 12 650 0.23 0.50 68 74
12
6
0,2

11

40
10
Technology

9 5 1
0 2000 4000 6000 [CFM]

2000 4000 6000 8000 10000 12000 [m3/h]


Contacts

241
Drawings Electr. connection
p. 242 f. p. 427
EC axial fans mains-powered
S series, Ø 630, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
A3G 630-AE37 -11 9.1
A3G 630-AE42 -06 9.1
A3G 630-AE31 -01 9.1

Depth of screw
12-16 mm
Cable gland

 "V"

Type Mass
With full square nozzle [kg]
W3G 630-CE37 -11 20.4
W3G 630-CE42 -06 20.4
W3G 630-CE31 -01 20.4

 "V"

Type Mass
With guard grille for full nozzle [kg]
S3G 630-BE37 -11 12.8
S3G 630-BE42 -06 12.8
S3G 630-BE31 -01 12.8

 "V"

242
 "V"
With guard grille for short nozzle
Type

S3G 630-AE31 -01


S3G 630-AE42 -06
S3G 630-AE37 -11
[kg]

14.6
14.6
14.6
Mass

243
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 630

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Blade angle

Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 428

*3G 630 M3G 150-FF 0° A 3~ 200-240 50/60 1220 1.70 5.20 215 -25 to +60 M)

*3G 630 M3G 150-FF 0° B 3~ 380-480 50/60 1220 1.70 2.60 215 -25 to +60 M)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

1220 1.30 4.00 77 —


[in H2O]
[Pa]

A A 1

220
A 2 1220 1.52 4.80 76 77
4
A 3 1220 1.60 5.00 78 70
0,8

200 A 4 1220 1.70 5.20 81 58

180
A 5 1100 0.95 3.00 75 —
8
3
A 6 1100 1.11 3.60 74 77
160 A 7 1100 1.18 3.60 76 70
0,6

A 8 1100 1.24 3.80 79 58


140 12
7
A 9 980 0.67 2.20 72 —
120 A 10 980 0.79 2.40 72 77
2
11 A 11 980 0.83 2.60 73 70
0,4

100
6
A 12 980 0.88 2.80 76 58
80
10

60
0,2

40

20

9 5 1
0 2500 5000 7500 10000 [CFM]

4000 8000 12000 16000 [m3/h]

244
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST; B also VDE
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A" 
Without With full With guard grille With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle for full nozzle

EC axial fans
"V" A3G 630-AG12 -13 W3G 630-CG12 -13 S3G 630-BG12 -13 S3G 630-AG12 -13 —
"A" A3G 630-AG12 -14 W3G 630-CG12 -14 — — S3G 630-CG12 -14
"V" A3G 630-AG08 -03 W3G 630-CG08 -03 S3G 630-BG08 -03 S3G 630-AG08 -03 —
"A" A3G 630-AG08 -04 W3G 630-CG08 -04 — — S3G 630-CG08 -04

EC axial
S series
Q-motor
n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

1220 1.30 2.00 77 —


[in H2O]
[Pa]

B B 1

ESM
220
B 2 1220 1.52 2.40 76 77
4
B 3 1220 1.60 2.50 78 70
0,8

200 B 4 1220 1.70 2.60 81 58

180
B 5 1100 0.95 1.50 75 —
8
1100 1.11 1.80 74 77
EC-SYSTEMS
B 6
3
160 B 7 1100 1.18 1.80 76 70
0,6

B 8 1100 1.24 1.90 79 58


140 12
7
B 9 980 0.67 1.10 72 —
120 B 10 980 0.79 1.20 72 77
2
11 B 11 980 0.83 1.30 73 70
0,4

100
Accessories

6
B 12 980 0.88 1.40 76 58
80
10

60
0,2

40
Technology

20

9 5 1
0 2500 5000 7500 10000 [CFM]

4000 8000 12000 16000 [m3/h]


Contacts

245
Drawings Electr. connection
p. 248 ff. p. 428
EC axial fans mains-powered
S series, Ø 630

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Blade angle

Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 428

*3G 630 M3G 150-IF 0° A 3~ 200-240 50/60 1490 3.10 9.40 340 -25 to +60 M)

*3G 630 M3G 150-IF 0° B 3~ 380-480 50/60 1490 3.10 4.70 340 -25 to +60 M)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

1490 2.35 7.20 82 —


[in H2O]
[Pa]

A A 1

A 2 1490 2.77 8.40 82 74


4
A 3 1490 2.94 9.00 84 64
320
A 4 1490 3.10 9.40 87 55
8
1,2

A 5 1400 1.95 6.00 80 —


280 3
A 6 1400 2.30 7.00 80 74
12
1400 2.44 7.40 83 64
1,0

A 7
240 7
A 8 1400 2.55 7.80 85 55
11 A 9 1300 1.56 4.80 79 —
200
0,8

2
A 10 1300 1.84 5.60 79 74
6
A 11 1300 1.95 6.00 81 64
160
0,6

10 A 12 1300 2.04 6.20 84 55

120
0,4

80
0,2

40

9 5 1
0 4000 8000 12000 [CFM]

4000 8000 12000 16000 20000 [m3/h]

246
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST; B also VDE
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A" 
Without With full With guard grille With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle for full nozzle

EC axial fans
"V" A3G 630-AH07 -13 W3G 630-CH07 -13 S3G 630-BH07 -13 S3G 630-AH07 -13 —
"A" A3G 630-AH07 -14 W3G 630-CH07 -14 — — S3G 630-CH07 -14
"V" A3G 630-AH02 -03 W3G 630-CH02 -03 S3G 630-BH02 -03 S3G 630-AH02 -03 —
"A" A3G 630-AH02 -04 W3G 630-CH02 -04 — — S3G 630-CH02 -04

EC axial
S series
Q-motor
n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

1490 2.35 3.60 82 —


[in H2O]
[Pa]

B B 1

ESM
B 2 1490 2.77 4.20 82 74
4
B 3 1490 2.94 4.50 84 64
320
B 4 1490 3.10 4.70 87 55
8
1,2

B 5 1400 1.95 3.00 80 —


280 3
1400 2.30 3.50 80 74
EC-SYSTEMS
B 6
12
1400 2.44 3.70 83 64
1,0

B 7
240 7
B 8 1400 2.55 3.90 85 55
11 B 9 1300 1.56 2.40 79 —
200
0,8

2
B 10 1300 1.84 2.80 79 74
6
B 11 1300 1.95 3.00 81 64
160
Accessories
0,6

10 B 12 1300 2.04 3.10 84 55

120
0,4

80
0,2

Technology

40

9 5 1
0 4000 8000 12000 [CFM]

4000 8000 12000 16000 20000 [m3/h]


Contacts

247
Drawings Electr. connection
p. 248 ff. p. 428
EC axial fans mains-powered
S series, Ø 630, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
A3G 630-AG08 -03 23.0
A3G 630-AG12 -13 23.0
A3G 630-AH02 -03 26.0
A3G 630-AH07 -13 26.0

Depth of screw
Cable gland 20-25 mm

 "V"

Type Mass
With full square nozzle [kg]
W3G 630-CG08 -03 38.0
W3G 630-CG12 -13 38.0
W3G 630-CH02 -03 41.0
W3G 630-CH07 -13 41.0

 "V"

Type Mass
With guard grille for full nozzle [kg]
S3G 630-BG08 -03 27.5
92
7,6

25

S3G 630-BG12 -13 27.5


View X S3G 630-BH02 -03 30.5
10

15
68
S3G 630-BH07 -13 30.5

 "V"

248
 "V"
With guard grille for short nozzle

S3G
S3G
S3G
S3G
Type

630-AH07
630-AH02
630-AG12
630-AG08

-13
-03
-13
-03
[kg]

29.5
29.5
26.5
26.5
Mass

249
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 630, drawings for direction of air flow "A"

Type Mass
Without attachments [kg]
A3G 630-AG08 -04 23.0
A3G 630-AG12 -14 23.0
A3G 630-AH02 -04 26.0
A3G 630-AH07 -14 26.0

Depth of screw
Cable gland 20-25 mm

"A" 

Type Mass
With full square nozzle [kg]
W3G 630-CG08 -04 39.0
W3G 630-CG12 -14 39.0
W3G 630-CH02 -04 42.0
W3G 630-CH07 -14 42.0

"A" 

Type Mass
With guard grille for full nozzle [kg]
S3G 630-CG08 -04 28.5
S3G 630-CG12 -14 28.5
S3G 630-CH02 -04 31.5
S3G 630-CH07 -14 31.5

"A" 

250
251
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 650

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 427

*3G 650 M3G 112-GA A 1~ 200-277 50/60 890 0.66 3.00 90 -25 to +60 L1)
subject to alterations (1) Nominal data in operating point with maximum load and 230 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

A 1 910 0.55 2.50 76 —


[in H2O]
[Pa]

A
A 2 900 0.63 2.90 77 90
140 A 3 890 0.66 3.00 79 78
A 4 — — — — —

120 A 5 830 0.41 1.90 73 —


A 6 830 0.48 2.20 75 91
8 A 7 820 0.49 2.30 76 84
0,4

100
3
A 8 810 0.51 2.30 76 65
A 9 650 0.19 0.90 67 —
7
80 A 10 640 0.23 1.10 68 95
A 11 640 0.24 1.10 69 86
12
60
A 12 630 0.25 1.20 70 67
2
0,2

11
6
40

10

20

9 5 1
0 2000 4000 6000 [CFM]

2000 4000 6000 8000 10000 12000 [m3/h]

252
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage detection
• PFC (active) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-4 (industrial environment)
Interference immunity acc. to EN 61000-6-2 (industrial environment)
Harmonics acc. to DIN EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST; CCC is applied for
Direction of air flow

AC axial
A series
 "V"  "V"  "V"  "V"
Without With full With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle

EC axial fans
"V" A3G 650-AE34 -11 W3G 650-CE34 -01 S3G 650-BE34 -11 S3G 650-AE34 -11

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

253
Drawings Electr. connection
p. 256 f. p. 427
EC axial fans mains-powered
S series, Ø 650

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: PA plastic
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 427

*3G 650 M3G 112-GA A 3~ 200-240 50/60 910 0.72 2.60 125 -25 to +60 L2)

*3G 650 M3G 112-GA B 3~ 380-480 50/60 910 0.72 1.30 125 -25 to +60 L2)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

A 1 910 0.53 1.80 75 —


[in H2O]
[Pa]

A
A 2 910 0.62 2.20 77 87
140 A 3 910 0.66 2.40 78 74
A 4 910 0.72 2.60 79 60
4

120 A 5 830 0.39 1.60 73 —


A 6 810 0.43 1.60 74 91
A 7 790 0.43 1.60 74 79
0,4

100 8 3 A 8 790 0.46 1.80 75 62


A 9 630 0.17 0.80 66 —
80 A 10 620 0.19 0.80 67 94
7
A 11 600 0.19 0.80 67 83
60
A 12 610 0.21 0.80 67 63
12
2
0,2

11 6
40

10
20

9 5 1
0 2000 4000 6000 [CFM]

2000 4000 6000 8000 10000 12000 [m3/h]

254
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST; CCC is applied for
Direction of air flow

AC axial
A series
 "V"  "V"  "V"  "V"
Without With full With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle

EC axial fans
"V" A3G 650-AE44 -06 W3G 650-CE44 -06 S3G 650-BE44 -06 S3G 650-AE44 -08

"V" A3G 650-AE35 -01 W3G 650-CE35 -01 S3G 650-BE35 -01 S3G 650-AE35 -01

EC axial
S series
Q-motor
n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

B 1 910 0.53 0.90 75 —


[in H2O]
[Pa]

ESM
B 2 910 0.62 1.10 77 87
140 B 3 910 0.66 1.20 78 74
B 4 910 0.72 1.30 79 60
4

120 B 5 830 0.39 0.80 73 —


810 0.43 0.80 74 91
EC-SYSTEMS
B 6

B 7 790 0.43 0.80 74 79


0,4

100 8 3 B 8 790 0.46 0.90 75 62


B 9 630 0.17 0.40 66 —
80 B 10 620 0.19 0.40 67 94
7
B 11 600 0.19 0.40 67 83
Accessories

60
B 12 610 0.21 0.40 67 63
12
2
0,2

11 6
40

10
20
Technology

9 5 1
0 2000 4000 6000 [CFM]

2000 4000 6000 8000 10000 12000 [m3/h]


Contacts

255
Drawings Electr. connection
p. 256 f. p. 427
EC axial fans mains-powered
S series, Ø 650, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
A3G 650-AE34 -11 9.2
A3G 650-AE44 -06 9.2
A3G 650-AE35 -01 9.2

Depth of screw
12-16 mm
Cable gland

 "V"

Type Mass
With full square nozzle [kg]
W3G 650-CE34 -01 21.5
W3G 650-CE44 -06 21.5
W3G 650-CE35 -01 21.5

 "V"

Type Mass
With guard grille for full nozzle [kg]
S3G 650-BE34 -11 13.1
S3G 650-BE44 -06 13.1
S3G 650-BE35 -01 13.1

 "V"

256
 "V"
With guard grille for short nozzle
Type

S3G 650-AE35 -01


S3G 650-AE44 -08
S3G 650-AE34 -11
[kg]

14.7
14.7
14.7
Mass

257
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 650

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Blade angle

Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 428

*3G 650 M3G 150-FF -5° A 3~ 200-240 50/60 1250 1.65 5.20 240 -25 to +60 M)

*3G 650 M3G 150-FF -5° B 3~ 380-480 50/60 1250 1.65 2.60 240 -25 to +60 M)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

1250 1.07 3.20 78 —


[in H2O]
[Pa]

A A 1

240
4 A 2 1250 1.38 4.20 78 82
A 3 1250 1.52 4.60 80 71
220 A 4 1250 1.65 5.20 83 59
0,8

200 A 5 1100 0.73 2.20 76 —


8 A 6 1100 0.94 2.80 75 82
180 3
A 7 1100 1.03 3.20 77 71
160 A 8 1100 1.12 3.40 80 59
0,6

140 12 7 A 9 950 0.47 1.40 72 —


2
A 10 950 0.60 1.80 72 82
120 A 11 950 0.67 2.00 74 71
11 A 12 950 0.72 2.20 77 59
0,4

100 6

80
10

60
0,2

40

20

9 5 1
0 2500 5000 7500 10000 [CFM]

4000 8000 12000 16000 [m3/h]

258
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST; B also VDE
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A" 
Without With full With guard grille With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle for full nozzle

EC axial fans
"V" A3G 650-AJ12 -13 W3G 650-CJ12 -13 S3G 650-BJ12 -13 — —
"A" A3G 650-AJ12 -14 W3G 650-CJ12 -14 — — S3G 650-CJ12 -14
"V" A3G 650-AJ08 -03 W3G 650-CJ08 -03 S3G 650-BJ08 -03 — —
"A" A3G 650-AJ08 -04 W3G 650-CJ08 -04 — — S3G 650-CJ08 -04

EC axial
S series
Q-motor
n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

1250 1.07 1.60 78 —


[in H2O]
[Pa]

B B 1

ESM
240
4 B 2 1250 1.38 2.10 78 82
B 3 1250 1.52 2.30 80 71
220 B 4 1250 1.65 2.60 83 59
0,8

200 B 5 1100 0.73 1.10 76 —


8 1100 0.94 1.40 75 82
EC-SYSTEMS
B 6
180 3
B 7 1100 1.03 1.60 77 71
160 B 8 1100 1.12 1.70 80 59
0,6

140 12 7 B 9 950 0.47 0.70 72 —


2
B 10 950 0.60 0.90 72 82
120 B 11 950 0.67 1.00 74 71
Accessories

11 B 12 950 0.72 1.10 77 59


0,4

100 6

80
10

60
0,2

40
Technology

20

9 5 1
0 2500 5000 7500 10000 [CFM]

4000 8000 12000 16000 [m3/h]


Contacts

259
Drawings Electr. connection
p. 262 ff. p. 428
EC axial fans mains-powered
S series, Ø 650

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Blade angle

Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 428

*3G 650 M3G 150-IF -5° A 3~ 200-240 50/60 1500 2.87 8.80 350 -25 to +60 M)

*3G 650 M3G 150-IF -5° B 3~ 380-480 50/60 1500 2.87 4.40 350 -25 to +60 M)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

1500 1.86 5.60 82 —


[in H2O]
[Pa]

A A 1

A 2 1500 2.37 7.20 82 82


360
4 1500 2.65 8.00 84 70
1,4

A 3

A 4 1500 2.87 8.80 87 59


320
A 5 1350 1.35 4.20 80 —
1,2

280 8 A 6 1350 1.73 5.20 80 82


3
A 7 1350 1.93 5.80 82 70
1,0

240 A 8 1350 2.09 6.40 85 59


12
7 A 9 1200 0.95 3.00 78 —
200
0,8

A 10 1200 1.21 3.60 77 82


11
2 A 11 1200 1.35 4.20 79 70
160 A 12 1200 1.47 4.40 82 59
0,6

120
10
0,4

80
0,2

40

9 5 1
0 4000 8000 12000 [CFM]

4000 8000 12000 16000 20000 [m3/h]

260
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST; B also VDE
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A" 
Without With full With guard grille With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle for full nozzle

EC axial fans
"V" A3G 650-AK07 -13 W3G 650-CK07 -13 S3G 650-BK07 -13 — —
"A" A3G 650-AK07 -14 W3G 650-CK07 -14 — — S3G 650-CK07 -14
"V" A3G 650-AK02 -03 W3G 650-CK02 -03 S3G 650-BK02 -03 — —
"A" A3G 650-AK02 -04 W3G 650-CK02 -04 — — S3G 650-CK02 -04

EC axial
S series
Q-motor
n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

1500 1.86 2.80 82 —


[in H2O]
[Pa]

B B 1

ESM
B 2 1500 2.37 3.60 82 82
360
4 1500 2.65 4.00 84 70
1,4

B 3

B 4 1500 2.87 4.40 87 59


320
B 5 1350 1.35 2.10 80 —
1,2

8 1350 1.73 2.60 80 82


EC-SYSTEMS
B 6
280
3
B 7 1350 1.93 2.90 82 70
1,0

240 B 8 1350 2.09 3.20 85 59


12
7 B 9 1200 0.95 1.50 78 —
200
0,8

B 10 1200 1.21 1.80 77 82


11
2 B 11 1200 1.35 2.10 79 70
Accessories

160 B 12 1200 1.47 2.20 82 59


0,6

120
10
0,4

80
0,2

Technology

40

9 5 1
0 4000 8000 12000 [CFM]

4000 8000 12000 16000 20000 [m3/h]


Contacts

261
Drawings Electr. connection
p. 262 ff. p. 428
EC axial fans mains-powered
S series, Ø 650, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
A3G 650-AJ12 -13 23.5
A3G 650-AJ08 -03 23.5
A3G 650-AK07 -13 26.5
A3G 650-AK02 -03 26.5

Depth of screw
Cable gland 20-25 mm

 "V"

Type Mass
With full square nozzle [kg]
W3G 650-CJ12 -13 40.0
W3G 650-CJ08 -03 40.0
W3G 650-CK07 -13 43.0
W3G 650-CK02 -03 43.0

 "V"

Type Mass
With guard grille for full nozzle [kg]
S3G 650-BJ12 -13 28.5
92
7,6

25

S3G 650-BJ08 -03 28.5


View X S3G 650-BK07 -13 31.5
10

15
68
S3G 650-BK02 -03 31.5

 "V"

262
263
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 650, drawings for direction of air flow "A"

Type Mass
Without attachments [kg]
A3G 650-AJ12 -14 23.5
A3G 650-AJ08 -04 23.5
A3G 650-AK07 -14 26.5
A3G 650-AK02 -04 26.5

Depth of screw
Cable gland 20-25 mm

"A" 

Type Mass
With full square nozzle [kg]
W3G 650-CJ12 -14 41.0
W3G 650-CJ08 -04 41.0
W3G 650-CK07 -14 44.0
W3G 650-CK02 -04 44.0

"A" 

Type Mass
With guard grille for full nozzle [kg]
S3G 650-CJ12 -14 29.5
S3G 650-CJ08 -04 29.5
S3G 650-CK07 -14 32.5
S3G 650-CK02 -04 32.5

"A" 

264
265
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 710

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Blade angle

Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 428

*3G 710 M3G 150-FF 0° A 3~ 200-240 50/60 1050 1.68 5.20 160 -25 to +60 M)

*3G 710 M3G 150-FF 0° B 3~ 380-480 50/60 1050 1.68 2.60 160 -25 to +60 M)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

1050 1.26 3.80 76 —


[in H2O]
[Pa]

A A 1

4
A 2 1050 1.57 4.80 76 73
160 1050
A 3 1.63 5.00 77 68
0,6

A 4 1050 1.68 5.20 79 63


140 3
8
A 5 950 0.94 2.80 74 —
A 6 950 1.17 3.60 74 73
120 A 7 950 1.22 3.80 75 68
7 2
12
A 8 950 1.25 3.80 77 63
100
0,4

A 9 850 0.67 2.00 72 —


11 6
A 10 850 0.84 2.60 72 73
80 A 11 850 0.87 2.60 73 68
10
A 12 850 0.90 2.80 74 63
60
0,2

40

20

9 5 1
0 4000 8000 12000 [CFM]

4000 8000 12000 16000 20000 [m3/h]

266
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST; B also VDE
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A" 
Without With full With guard grille With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle for full nozzle

EC axial fans
"V" A3G 710-AG09 -13 W3G 710-CG09 -13 S3G 710-BG09 -13 S3G 710-AG09 -13 —
"A" A3G 710-AG09 -14 W3G 710-CG09 -14 — — S3G 710-CG09 -14
"V" A3G 710-AG01 -03 W3G 710-CG01 -03 S3G 710-BG01 -03 S3G 710-AG01 -03 —
"A" A3G 710-AG01 -04 W3G 710-CG01 -04 — — S3G 710-CG01 -04

EC axial
S series
Q-motor
n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

1050 1.26 1.90 76 —


[in H2O]
[Pa]

B B 1

ESM
4
B 2 1050 1.57 2.40 76 73
160 1050
B 3 1.63 2.50 77 68
0,6

B 4 1050 1.68 2.60 79 63


140 3
8
B 5 950 0.94 1.40 74 —
950 1.17 1.80 74 73
EC-SYSTEMS
B 6
120 B 7 950 1.22 1.90 75 68
7 2
12
B 8 950 1.25 1.90 77 63
100
0,4

B 9 850 0.67 1.00 72 —


11 6
B 10 850 0.84 1.30 72 73
80 B 11 850 0.87 1.30 73 68
Accessories

10
B 12 850 0.90 1.40 74 63
60
0,2

40

20
Technology

9 5 1
0 4000 8000 12000 [CFM]

4000 8000 12000 16000 20000 [m3/h]


Contacts

267
Drawings Electr. connection
p. 270 ff. p. 428
EC axial fans mains-powered
S series, Ø 710

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Blade angle

Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 428

*3G 710 M3G 150-IF 0° A 3~ 200-240 50/60 1240 2.75 8.50 255 -25 to +60 M)

*3G 710 M3G 150-IF 0° B 3~ 380-480 50/60 1240 2.75 4.20 255 -25 to +60 M)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

1240 1.99 6.00 80 —


[in H2O]
[Pa]

A A 1

A 2 1240 2.47 7.50 80 74


4
1,0

A 3 1240 2.59 7.80 81 67


240
A 4 1240 2.70 8.40 84 61
A 5 1100 1.39 4.20 77 —
200 3
0,8

8 A 6 1100 1.72 5.20 77 74


A 7 1100 1.81 5.40 79 67
A 8 1100 1.89 5.60 82 61
160 7
2 A 9 960 0.92 2.80 74 —
12
0,6

A 10 960 1.15 3.40 74 74


120 11 6 A 11 960 1.20 3.60 76 67
A 12 960 1.25 3.80 79 61
0,4

10
80
0,2

40

9 5 1
0 4000 8000 12000 16000 [CFM]

5000 10000 15000 20000 25000 [m3/h]

268
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST; B also VDE
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A" 
Without With full With guard grille With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle for full nozzle

EC axial fans
"V" A3G 710-AH10 -13 W3G 710-CH10 -13 S3G 710-BH10 -13 S3G 710-AH10 -13 —
"A" A3G 710-AH10 -14 W3G 710-CH10 -14 — — S3G 710-CH10 -14
"V" A3G 710-AH06 -03 W3G 710-CH06 -03 S3G 710-BH06 -03 S3G 710-AH06 -03 —
"A" A3G 710-AH06 -04 W3G 710-CH06 -04 — — S3G 710-CH06 -04

EC axial
S series
Q-motor
n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

1240 1.99 3.00 80 —


[in H2O]
[Pa]

B B 1

ESM
B 2 1240 2.47 3.70 80 74
4
1,0

B 3 1240 2.59 3.90 81 67


240
B 4 1240 2.70 4.20 84 61
B 5 1100 1.39 2.10 77 —
200 3
0,8

1100 1.72 2.60 77 74


EC-SYSTEMS
8 B 6

B 7 1100 1.81 2.70 79 67


B 8 1100 1.89 2.80 82 61
160 7
2 B 9 960 0.92 1.40 74 —
12
0,6

B 10 960 1.15 1.70 74 74


120 11 6 B 11 960 1.20 1.80 76 67
Accessories

B 12 960 1.25 1.90 79 61


0,4

10
80
0,2

40
Technology

9 5 1
0 4000 8000 12000 16000 [CFM]

5000 10000 15000 20000 25000 [m3/h]


Contacts

269
Drawings Electr. connection
p. 270 ff. p. 428
EC axial fans mains-powered
S series, Ø 710, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
A3G 710-AG09 -13 24.0
A3G 710-AG01 -03 24.0
A3G 710-AH10 -13 27.0
A3G 710-AH06 -03 27.0

Depth of screw
Cable gland 20-25 mm

 "V"

Type Mass
With full square nozzle [kg]
W3G 710-CG09 -13 43.5
W3G 710-CG01 -03 43.5
W3G 710-CH10 -13 46.5
W3G 710-CH06 -03 46.5

 "V"

Type Mass
With guard grille for full nozzle [kg]
S3G 710-BG09 -13 29.5
92
7,6

25

S3G 710-BG01 -03 29.5


View X S3G 710-BH10 -13 32.5
10

15
68
S3G 710-BH06 -03 32.5

 "V"

270
 "V"
With guard grille for short nozzle

S3G
S3G
S3G
S3G
Type

710-AH06
710-AH10
710-AG01
710-AG09

-03
-13
-03
-13
[kg]

31.0
31.0
28.0
28.0
Mass

271
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 710, drawings for direction of air flow "A"

Type Mass
Without attachments [kg]
A3G 710-AG09 -14 24.0
A3G 710-AG01 -04 24.0
A3G 710-AH10 -14 27.0
A3G 710-AH06 -04 27.0

Depth of screw
Cable gland 20-25 mm

"A" 

Type Mass
With full square nozzle [kg]
W3G 710-CG09 -14 44.5
W3G 710-CG01 -04 44.5
W3G 710-CH10 -14 47.5
W3G 710-CH06 -04 47.5

"A" 

Type Mass
With guard grille for full nozzle [kg]
S3G 710-CG09 -14 30.5
S3G 710-CG01 -04 30.5
S3G 710-CH10 -14 33.5
S3G 710-CH06 -04 33.5

"A" 

272
273
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 800

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Blade angle

Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 428

*3G 800 M3G 150-FF 0° A 3~ 200-240 50/60 830 1.35 4.40 155 -25 to +60 M)

*3G 800 M3G 150-FF 0° B 3~ 380-480 50/60 830 1.35 2.20 155 -25 to +60 M)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

830 0.88 2.80 72 —


[in H2O]
[Pa]

A A 1

A 2 830 1.13 3.40 70 75


160 830
A 3 1.24 3.80 72 67
0,6

4 A 4 830 1.35 4.40 77 57


140 A 5 750 0.65 2.00 69 —
A 6 750 0.83 2.60 68 75
120 8
3 A 7 750 0.91 2.80 70 67
A 8 750 0.99 3.00 75 57
100
0,4

12 7
A 9 670 0.46 1.40 67 —
A 10 670 0.60 1.80 66 75
2
80 A 11 670 0.65 2.00 68 67
11
A 12 670 0.71 2.20 72 57
6
60
10
0,2

40

20

9 5 1
0 4000 8000 12000 [CFM]

4000 8000 12000 16000 20000 [m3/h]

274
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST; B also VDE
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A" 
Without With full With guard grille With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle for full nozzle

EC axial fans
"V" A3G 800-AG10 -13 W3G 800-CG10 -13 S3G 800-BG10 -13 S3G 800-AG10 -13 —
"A" A3G 800-AG10 -14 W3G 800-CG10 -14 — — S3G 800-CG10 -14
"V" A3G 800-AG02 -03 W3G 800-CG02 -03 S3G 800-BG02 -03 S3G 800-AG02 -03 —
"A" A3G 800-AG02 -04 W3G 800-CG02 -04 — — S3G 800-CG02 -04

EC axial
S series
Q-motor
n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

830 0.88 1.40 72 —


[in H2O]
[Pa]

B B 1

ESM
B 2 830 1.13 1.70 70 75
160 830
B 3 1.24 1.90 72 67
0,6

4 B 4 830 1.35 2.20 77 57


140 B 5 750 0.65 1.00 69 —
750 0.83 1.30 68 75
EC-SYSTEMS
B 6
120 8
3 B 7 750 0.91 1.40 70 67
B 8 750 0.99 1.50 75 57
100
0,4

12 7
B 9 670 0.46 0.70 67 —
B 10 670 0.60 0.90 66 75
2
80 B 11 670 0.65 1.00 68 67
11
Accessories

B 12 670 0.71 1.10 72 57


6
60
10
0,2

40

20
Technology

9 5 1
0 4000 8000 12000 [CFM]

4000 8000 12000 16000 20000 [m3/h]


Contacts

275
Drawings Electr. connection
p. 278 ff. p. 428
EC axial fans mains-powered
S series, Ø 800

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Blade angle

Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 428

*3G 800 M3G 150-IF 0° A 3~ 200-240 50/60 980 2.20 6.80 230 -25 to +60 M)

*3G 800 M3G 150-IF 0° B 3~ 380-480 50/60 980 2.20 3.40 230 -25 to +60 M)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

980 1.37 4.20 74 —


[in H2O]
[Pa]

A A 1
4
A 2 980 1.76 5.40 73 78
A 3 980 1.93 5.80 76 67
200
0,8

A 4 980 2.20 6.80 82 52


8

3
A 5 900 1.06 3.20 73 —
A 6 900 1.36 4.20 72 78
160 12 A 7 900 1.50 4.30 73 67
7
0,6

A 8 900 1.71 5.20 80 52


A 9 820 0.80 2.40 71 —
11
120 2
A 10 820 1.03 3.20 70 78
A 11 820 1.13 3.40 73 67
0,4

6
A 12 820 1.30 4.00 78 52
80 10
0,2

40

9 5 1
0 4000 8000 12000 16000 [CFM]

5000 10000 15000 20000 25000 [m3/h]

276
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST; B also VDE
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A" 
Without With full With guard grille With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle for full nozzle

EC axial fans
"V" A3G 800-AH12 -13 W3G 800-CH12 -13 S3G 800-BH12 -13 S3G 800-AH12 -13 —
"A" A3G 800-AH12 -14 W3G 800-CH12 -14 — — S3G 800-CH12 -14
"V" A3G 800-AH03 -03 W3G 800-CH03 -03 S3G 800-BH03 -03 S3G 800-AH03 -03 —
"A" A3G 800-AH03 -04 W3G 800-CH03 -04 — — S3G 800-CH03 -04

EC axial
S series
Q-motor
n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

980 1.37 2.10 74 —


[in H2O]
[Pa]

B B 1
4

ESM
B 2 980 1.76 2.70 73 78
B 3 980 1.93 2.90 76 67
200
0,8

B 4 980 2.20 3.40 82 52


8

3
B 5 900 1.06 1.60 73 —
900 1.36 2.10 72 78
EC-SYSTEMS
B 6

160 12 B 7 900 1.50 2.30 73 67


7
0,6

B 8 900 1.71 2.60 80 52


B 9 820 0.80 1.20 71 —
11
120 2
B 10 820 1.03 1.60 70 78
B 11 820 1.13 1.70 73 67
0,4

Accessories

6
B 12 820 1.30 2.00 78 52
80 10
0,2

40
Technology

9 5 1
0 4000 8000 12000 16000 [CFM]

5000 10000 15000 20000 25000 [m3/h]


Contacts

277
Drawings Electr. connection
p. 278 ff. p. 428
EC axial fans mains-powered
S series, Ø 800, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
A3G 800-AG10 -13 25.0
A3G 800-AG02 -03 25.0
A3G 800-AH12 -13 28.0
A3G 800-AH03 -03 28.0

Depth of screw
Cable gland 20-25 mm

 "V"

Type Mass
With full square nozzle [kg]
W3G 800-CG10 -13 46.5
W3G 800-CG02 -03 46.5
W3G 800-CH12 -13 49.5
W3G 800-CH03 -03 49.5

 "V"

Type Mass
With guard grille for full nozzle [kg]
S3G 800-BG10 -13 31.5
92
7,6

25

S3G 800-BG02 -03 31.5


View X S3G 800-BH12 -13 34.5
15

15
68
S3G 800-BH03 -03 34.5

 "V"

278
 "V"
With guard grille for short nozzle

S3G
S3G
S3G
S3G
Type

800-AH03
800-AH12
800-AG02
800-AG10

-03
-13
-03
-13
[kg]

33.0
33.0
30.0
30.0
Mass

279
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 800, drawings for direction of air flow "A"

Type Mass
Without attachments [kg]
A3G 800-AG10 -14 25.0
A3G 800-AG02 -04 25.0
A3G 800-AH12 -14 28.0
A3G 800-AH03 -04 28.0

Depth of screw
Cable gland 20-25 mm

"A" 

Type Mass
With full square nozzle [kg]
W3G 800-CG10 -14 47.5
W3G 800-CG02 -04 47.5
W3G 800-CH12 -14 50.5
W3G 800-CH03 -04 50.5

"A" 

Type Mass
With guard grille for full nozzle [kg]
S3G 800-CG10 -14 32.5
S3G 800-CG02 -04 32.5
S3G 800-CH12 -14 35.5
S3G 800-CH03 -04 35.5

"A" 

280
281
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 910

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Blade angle

Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 428

*3G 910 M3G 150-FF 0° A 3~ 200-240 50/60 720 1.15 3.60 100 -25 to +60 M)

*3G 910 M3G 150-FF 0° B 3~ 380-480 50/60 720 1.15 1.80 100 -25 to +60 M)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

720 0.77 2.40 72 —


[in H2O]
[Pa]

A A 1

A 2 720 0.99 3.00 71 75


A 3 720 1.08 3.40 71 70
100
0,4

4 A 4 720 1.15 3.60 72 64


A 5 650 0.56 1.80 70 —
A 6 650 0.72 2.20 68 75
80 8 A 7 650 0.78 2.40 68 70
3
0,3

A 8 650 0.84 2.60 70 64

12
A 9 580 0.40 1.20 67 —
7
60 A 10 580 0.51 1.60 66 75
2 A 11 580 0.55 1.80 66 70
0,2

11
A 12 580 0.60 1.80 68 64
6
40
10
0,1

20

9 5 1
0 4000 8000 12000 16000 [CFM]

5000 10000 15000 20000 25000 [m3/h]

282
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST; B also VDE
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A" 
Without With full With guard grille With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle for full nozzle

EC axial fans
"V" A3G 910-AG10 -13 W3G 910-CG10 -13 S3G 910-BG10 -13 S3G 910-AG10 -13 —
"A" A3G 910-AG10 -14 W3G 910-CG10 -14 — — S3G 910-CG10 -14
"V" A3G 910-AG02 -03 W3G 910-CG02 -03 S3G 910-BG02 -03 S3G 910-AG02 -03 —
"A" A3G 910-AG02 -04 W3G 910-CG02 -04 — — S3G 910-CG02 -04

EC axial
S series
Q-motor
n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

720 0.77 1.20 72 —


[in H2O]
[Pa]

B B 1

ESM
B 2 720 0.99 1.50 71 75
B 3 720 1.08 1.70 71 70
100
0,4

4 B 4 720 1.15 1.80 72 64


B 5 650 0.56 0.90 70 —
650 0.72 1.10 68 75
EC-SYSTEMS
B 6

80 8 B 7 650 0.78 1.20 68 70


3
0,3

B 8 650 0.84 1.30 70 64

12
B 9 580 0.40 0.60 67 —
7
60 B 10 580 0.51 0.80 66 75
2 B 11 580 0.55 0.90 66 70
0,2

11
Accessories

B 12 580 0.60 0.90 68 64


6
40
10
0,1

20
Technology

9 5 1
0 4000 8000 12000 16000 [CFM]

5000 10000 15000 20000 25000 [m3/h]


Contacts

283
Drawings Electr. connection
p. 288 ff. p. 428
EC axial fans mains-powered
S series, Ø 910

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Blade angle

Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 428

*3G 910 M3G 150-IF 0° A 3~ 200-240 50/60 870 1.90 5.80 140 -25 to +60 M)

*3G 910 M3G 150-IF 0° B 3~ 380-480 50/60 870 1.90 2.90 140 -25 to +60 M)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

870 1.30 4.00 76 —


[in H2O]
[Pa]

A A 1

A 2 870 1.62 5.00 75 74


4
140 A 3 870 1.76 5.40 75 71
A 4 870 1.90 5.80 77 66
0,5

120 8
A 5 800 1.01 3.20 74 —
A 6 800 1.26 3.80 73 74
3
A 7 800 1.35 4.20 73 71
100
0,4

12
A 8 800 1.46 4.40 75 66
7
A 9 730 0.77 2.40 72 —
80 A 10 730 0.76 3.00 71 74
0,3

11
2 A 11 730 1.03 3.20 71 71

60 6
A 12 730 1.11 3.40 73 66

10
0,2

40
0,1

20

9 5 1
0 4000 8000 12000 16000 [CFM]

5000 10000 15000 20000 25000 30000 [m3/h]

284
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST; B also VDE
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A" 
Without With full With guard grille With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle for full nozzle

EC axial fans
"V" A3G 910-AH09 -13 W3G 910-CH09 -13 S3G 910-BH09 -13 S3G 910-AH09 -13 —
"A" A3G 910-AH09 -14 W3G 910-CH09 -14 — — S3G 910-CH09 -14
"V" A3G 910-AH04 -03 W3G 910-CH04 -03 S3G 910-BH04 -03 S3G 910-AH04 -03 —
"A" A3G 910-AH04 -04 W3G 910-CH04 -04 — — S3G 910-CH04 -04

EC axial
S series
Q-motor
n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

870 1.30 2.00 76 —


[in H2O]
[Pa]

B B 1

ESM
B 2 870 1.62 2.50 75 74
4
140 B 3 870 1.76 2.70 75 71
B 4 870 1.90 2.90 77 66
0,5

120 8
B 5 800 1.01 1.60 74 —
800 1.26 1.90 73 74
EC-SYSTEMS
B 6
3
B 7 800 1.35 2.10 73 71
100
0,4

12
B 8 800 1.46 2.20 75 66
7
B 9 730 0.77 1.20 72 —
80 B 10 730 0.76 1.50 71 74
0,3

11
2 B 11 730 1.03 1.60 71 71
Accessories

60 6
B 12 730 1.11 1.70 73 66

10
0,2

40
0,1

20
Technology

9 5 1
0 4000 8000 12000 16000 [CFM]

5000 10000 15000 20000 25000 30000 [m3/h]


Contacts

285
Drawings Electr. connection
p. 288 ff. p. 428
EC axial fans mains-powered
S series, Ø 910

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Blade angle

Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 428

*3G 910 M3G 150-NA 0° A 3~ 380-480 50/60 980 2.80 4.30 220 -25 to +60 M)
subject to alterations (1) Nominal data in operating point with maximum load and 400 VAC

n P1 I LwA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

980 1.82 2.80 80 —


[in H2O]
[Pa]

A A 1

220 4 A 2 980 2.24 3.40 80 73


A 3 980 2.55 3.90 83 65
200
0,8

A 4 980 2.80 4.30 86 56


8
180
A 5 900 1.41 2.20 78 —
A 6 900 1.76 2.60 78 73
3
160 A 7 900 1.97 3.00 82 65
12
0,6

A 8 900 2.15 3.30 84 56


140 7
A 9 820 1.07 1.60 76 —
120 A 10 820 1.31 2.00 76 73
11
A 11 820 1.49 2.30 80 65
100
0,4

A 12 820 1.63 2.50 82 56


2
80
6

10
60
0,2

40

20

9 5 1
0 4000 8000 12000 16000 [CFM]

5000 10000 15000 20000 25000 30000 [m3/h]

286
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A" 
Without With full With guard grille With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle for full nozzle

EC axial fans
"V" A3G 910-AI02 -03 W3G 910-CI02 -03 S3G 910-BI02 -03 S3G 910-AI02 -03 —
"A" A3G 910-AI02 -04 W3G 910-CI02 -04 — — S3G 910-CI02 -04

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

287
Drawings Electr. connection
p. 288 ff. p. 428
EC axial fans mains-powered
S series, Ø 910, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] g
A3G 910-AG10 -13 25.5 249.5
A3G 910-AG02 -03 25.5 249.5
A3G 910-AH09 -13 28.5 249.5
A3G 910-AH04 -03 28.5 249.5
A3G 910-AI02 -03 33.0 284.5

Depth of screw
Cable gland 20-25 mm

 "V"

Type Mass
With full square nozzle [kg]
W3G 910-CG10 -13 51.0
W3G 910-CG02 -03 51.0
W3G 910-CH09 -13 54.0
W3G 910-CH04 -03 54.0
W3G 910-CI02 -03 58.5

 "V"

Type Mass
With guard grille for full nozzle [kg] t
S3G 910-BG10 -13 34.0 134.5
116
29
10

S3G 910-BG02 -03 34.0 134.5


View X S3G 910-BH09 -13 37.0 134.5
15

20
76
S3G 910-BH04 -03 37.0 134.5
S3G 910-BI02 -03 41.5 169.5

 "V"

288
information
General
AC axial fans
Type Mass
With guard grille for short nozzle [kg] v
S3G 910-AG10 -13 36.0 19.5
S3G 910-AG02 -03 36.0 19.5
S3G 910-AH09 -13 39.0 19.5

AC axial
S series
S3G 910-AH04 -03 39.0 19.5
S3G 910-AI02 -03 43.5 54.5

AC axial
K series
AC axial
A series
 "V"

EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

289
EC axial fans mains-powered
S series, Ø 910, drawings for direction of air flow "A"

Type Mass
Without attachments [kg] g
A3G 910-AG10 -14 25.5 249.5
A3G 910-AG02 -04 25.5 249.5
A3G 910-AH09 -14 28.5 249.5
A3G 910-AH04 -04 28.5 249.5
A3G 910-AI02 -04 33.0 284.5

Depth of screw
Cable gland 20-25 mm

"A" 

Type Mass
With full square nozzle [kg]
W3G 910-CG10 -14 52.0
W3G 910-CG02 -04 52.0
W3G 910-CH09 -14 55.0
W3G 910-CH04 -04 55.0
W3G 910-CI02 -04 59.5

"A" 

Type Mass
With guard grille for full nozzle [kg] t
S3G 910-CG10 -14 35.0 160.5
S3G 910-CG02 -04 35.0 160.5
S3G 910-CH09 -14 38.0 160.5
S3G 910-CH04 -04 38.0 160.5
S3G 910-CI02 -04 42.5 195.5

"A" 

290
291
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
EC axial fans mains-powered
S series, Ø 990

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 7
– Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 428

*3G 990 M3G 150-FF A 3~ 200-240 50/60 545 0.90 3.80 90 -25 to +60 M)

*3G 990 M3G 150-FF B 3~ 380-480 50/60 545 0.90 1.90 90 -25 to +60 M)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LpA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

A 1 545 0.63 2.40 70 —


[Pa]

[in H O]

A
2

A 2 545 0.74 2.60 71 72


A 3 545 0.81 2.80 71 70
120
A 4 545 0.88 3.00 70 57
A 5 450 0.36 1.40 65 —
0,4

100 A 6 450 0.42 1.60 66 72


A 7 450 0.46 1.80 66 70
4
A 8 450 0.50 1.80 65 57
80
A 9 380 0.22 0.80 61 —
0,3

A 10 380 0.26 1.00 61 72


60 8
A 11 380 0.28 1.20 61 70
3
A 12 380 0.31 1.20 61 57
0,2

12
40 7

11 2
0,1

20 6
10

9 5 1
0 3000 6000 9000 12000 15000 18000 [CFM]

5000 15000 25000 [m3/h]

292
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: UL, CSA, CCC, GOST; B also VDE
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A" 
Without With full With guard grille With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle for full nozzle

EC axial fans
"V" A3G 990-AC04 -13 W3G 990-CC04 -13 S3G 990-BC04 -13 — —
"A" A3G 990-AC04 -14 W3G 990-CC04 -14 — — S3G 990-CC04 -14
"V" A3G 990-AC03 -03 W3G 990-CC03 -03 S3G 990-BC03 -03 — —
"A" A3G 990-AC03 -04 W3G 990-CC03 -04 — — S3G 990-CC03 -04

EC axial
S series
Q-motor
n P1 I LpA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

B 1 545 0.63 1.20 70 —


[Pa]

[in H O]

B
2

ESM
B 2 545 0.74 1.30 71 72
B 3 545 0.81 1.40 71 70
120
B 4 545 0.88 1.50 70 57
B 5 450 0.36 0.70 65 —
0,4

100 450 0.42 0.80 66 72


EC-SYSTEMS
B 6

B 7 450 0.46 0.90 66 70


4
B 8 450 0.50 0.90 65 57
80
B 9 380 0.22 0.40 61 —
0,3

B 10 380 0.26 0.50 61 72


60 8
B 11 380 0.28 0.60 61 70
Accessories

3
B 12 380 0.31 0.60 61 57
0,2

12
40 7

11 2
0,1

20 6
Technology

10

9 5 1
0 3000 6000 9000 12000 15000 18000 [CFM]

5000 15000 25000 [m3/h]


Contacts

293
Drawings Electr. connection
p. 298 f. p. 428
EC axial fans mains-powered
S series, Ø 990

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 7
– Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 428

*3G 990 M3G 150-IF A 3~ 200-240 50/60 650 1.50 4.80 120 -25 to +60 M)

*3G 990 M3G 150-IF B 3~ 380-480 50/60 650 1.50 2.60 120 -25 to +60 M)
subject to alterations (1) Nominal data in operating point with maximum load and 200 or 400 VAC

n P1 I LpA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

A 1 650 1.02 3.60 75 —


[Pa]

[in H O]

A
2

A 2 650 1.21 4.00 76 72


4
A 3 650 1.32 4.40 76 70
120
A 4 650 1.44 4.60 75 57
A 5 540 0.60 2.20 70 —
0,4

100 A 6 540 0.71 2.60 71 72


A 7 540 0.78 2.80 71 70
8 A 8 540 0.84 3.00 70 57
80 3
A 9 450 0.36 1.40 65 —
0,3

A 10 450 0.42 1.60 66 72


60 12
A 11 450 0.46 1.80 66 70
7 A 12 450 0.50 1.80 65 57
0,2

40 11 2

6
0,1

20 10

9 5 1
0 3000 6000 9000 12000 15000 18000 [CFM]

5000 15000 25000 [m3/h]

294
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: UL, CSA, GOST; B also VDE
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A" 
Without With full With guard grille With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle for full nozzle

EC axial fans
"V" A3G 990-AD11 -13 W3G 990-CD11 -13 S3G 990-BD11 -13 — —
"A" A3G 990-AD11 -14 W3G 990-CD11 -14 — — S3G 990-CD11 -14
"V" A3G 990-AD05 -03 W3G 990-CD05 -03 S3G 990-BD05 -03 — —
"A" A3G 990-AD05 -04 W3G 990-CD05 -04 — — S3G 990-CD05 -04

EC axial
S series
Q-motor
n P1 I LpA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

B 1 650 1.02 1.80 75 —


[Pa]

[in H O]

B
2

ESM
B 2 650 1.21 2.00 76 72
4
B 3 650 1.32 2.20 76 70
120
B 4 650 1.44 2.30 75 57
B 5 540 0.60 1.10 70 —
0,4

100 540 0.71 1.30 71 72


EC-SYSTEMS
B 6

B 7 540 0.78 1.40 71 70


8 B 8 540 0.84 1.50 70 57
80 3
B 9 450 0.36 0.70 65 —
0,3

B 10 450 0.42 0.80 66 72


60 12
B 11 450 0.46 0.90 66 70
Accessories

7 B 12 450 0.50 0.90 65 57


0,2

40 11 2

6
0,1

20 10
Technology

9 5 1
0 3000 6000 9000 12000 15000 18000 [CFM]

5000 15000 25000 [m3/h]


Contacts

295
Drawings Electr. connection
p. 298 f. p. 428
EC axial fans mains-powered
S series, Ø 990

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Die-cast aluminium
Rotor: Cast-in with PA plastic
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 7
– Direction of rotation: Dir. of air flow "V" clockwise, "A" counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. operative range

Perm. amb. temp.

Electr. connection
voltage range

Max. current
Max. power
Speed/rpm
Frequency
Nominal

draw (1)
input (1)
Curve

Nominal data
Type Motor VAC Hz rpm kW A Pa °C p. 428

*3G 990 M3G 150-NA A 3~ 380-480 50/60 720 2.00 3.00 150 -25 to +60 M)
subject to alterations (1) Nominal data in operating point with maximum load and 400 VAC

n P1 I LpA tL
Curves [rpm] [kW] [A] [dB(A)] [%]

720 1.47 2.20 74 —


[in H O]

A 1
[Pa]

A
2

4
A 2 720 1.72 2.60 75 79
140 A 3 720 1.89 2.90 77 73
A 4 720 1.99 3.00 78 60
0,5

8
120 A 5 655 1.10 1.70 72 —
3
A 6 655 1.29 2.00 73 75
A 7 655 1.40 2.10 74 73
0,4

100 12
7 A 8 655 1.51 2.30 76 60
A 9 580 0.77 1.20 73 —
80 A 10 580 0.90 1.40 74 75
0,3

11
A 11 580 0.97 1.50 75 73
60 2 A 12 580 1.05 1.60 77 60
0,2

40 10
0,1

20

9 5 1
0 3000 6000 9000 12000 15000 18000 [CFM]

5000 15000 25000 [m3/h]

296
information
General
AC axial fans
– Technical features: • Slave output 0-10 V max. 3 mA • Line undervoltage / phase failure detection
• PFC (passive) • Output 20 VDC (±20 %) max. 50 mA • Motor current limitation
• Integrated PID controller • Output 10 VDC (+10 %) max. 10 mA • Over-temperature protected electronics / motor
• Control input 0-10 VDC / PWM • RS485 ebmBUS • Locked rotor protection
• Input for sensor 0-10 V or 4-20 mA • Alarm relay • Soft start

AC axial
S series
– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Connection leads: Via terminal strip
– Protection class: I (acc. to EN 61800-5-1)

AC axial
K series
– Product conforming to standard: CE
– Approvals: VDE, UL, CSA, GOST
Direction of air flow

AC axial
A series
 "V"/ "A"   "V"/ "A"   "V"  "V" "A" 
Without With full With guard grille With guard grille With guard grille
attachments square nozzle for full nozzle for short nozzle for full nozzle

EC axial fans
"V" A3G 990-AE03 -03 W3G 990-CE03 -03 S3G 990-BE03 -03 — —
"A" A3G 990-AE03 -04 W3G 990-CE03 -04 — — S3G 990-CE03 -04

EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

297
Drawings Electr. connection
p. 298 f. p. 428
EC axial fans mains-powered
S series, Ø 990, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] g
A3G 990-AC04 -13 26.5 219.5
A3G 990-AC03 -03 26.5 219.5
A3G 990-AD11 -13 30.5 249.5
A3G 990-AD05 -03 30.5 249.5
A3G 990-AE03 -03 35.0 284.5

Cable gland Depth of screw


20-25 mm
 "V"

Type Mass
With full square nozzle [kg]
W3G 990-CC04 -13 55.0
W3G 990-CC03 -03 55.0
W3G 990-CD11 -13 59.0
W3G 990-CD05 -03 59.0
W3G 990-CE03 -03 63.5

 "V"

Type Mass
With guard grille for full nozzle [kg] t
S3G 990-BC04 -13 36.5 122.0
76
S3G 990-BC03 -03 36.5 122.0
10

29

20
15

View X S3G 990-BD11 -13 40.5 152.0


116
S3G 990-BD05 -03 40.5 152.0
S3G 990-BE03 -03 45.0 187.0

 "V"

298
information
General
EC axial fans mains-powered
S series, Ø 990, drawings for direction of air flow "A"

AC axial fans
Type Mass
Without attachments [kg] g
A3G 990-AC04 -14 26.5 219.5
A3G 990-AC03 -04 26.5 219.5
A3G 990-AD11 -14 30.5 249.5

AC axial
S series
A3G 990-AD05 -04 30.5 249.5
A3G 990-AE03 -04 35.0 284.5

AC axial
K series
Cable gland Depth of screw

AC axial
A series
20-25 mm
"A" 

Type Mass
With full square nozzle

EC axial fans
[kg]
W3G 990-CC04 -14 56.0
W3G 990-CC03 -04 56.0
W3G 990-CD11 -14 60.0
W3G 990-CD05 -04 60.0
W3G 990-CE03 -04 64.5

EC axial
S series
Q-motor
"A" 

ESM
Type Mass
With guard grille for full nozzle [kg] t
S3G 990-CC04 -14 37.5 169.5 EC-SYSTEMS
S3G 990-CC03 -04 37.5 169.5
S3G 990-CD11 -14 41.5 199.5
S3G 990-CD05 -04 41.5 199.5
S3G 990-CE03 -04 46.0 234.5
Accessories
Technology

"A" 
Contacts

299
Multi-function

Plug terminal

UL and CSA
Standard

Frigo
Table of options
= available ex stock Page 302 Page 304 Page 305 Page 306 Page 307

18 mm (height 48 mm)  
Foot measure
26 mm (height 51 mm)    

A side (3 x M4, Ø 71.4 mm) 

Mount B side (3 x M4, Ø 71.4 mm)  

Thread ends, A side (4 x M4)     

Jacketed cable (3 x 0.5 mm2) 450 mm 1500 mm 1500 mm

Electr. terminals Plug terminal (3 x 0.5 mm2) 

UL jacketed cable (3 x AWG20) 450 mm

300
information
General
Square shaded-pole motors (Q-motors)

AC axial fans
Standard design 302

Multi-function design 304

Frigo design 305

AC axial
S series
Plug terminal design 306

UL and CSA design 307

Air performance curves 308

AC axial
K series
AC axial
A series
EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

301
Square shaded-pole motors
Standard design

– Foot mounting: Track dimension 26 mm (height 51 mm)


– Type of protection: IP 42
– Electrical connection: Jacketed cable 3 x 0.5 mm2 with brass lead tips
– Product conforming to standard: CE
– Approvals: VDE
– Curves: Page 308
Motor axial impeller

Perm. amb. temp.


Nominal voltage
Combination:

Power output

Current draw
Power input
Speed/rpm
Frequency
Curve

Mass
Nominal data Dimensions
Type VAC Hz rpm W W A °C kg B E K

A 1~ 230 50 1300 5 29 0.19 -30 to +40


M4Q 045-BD01 -01 A B 1~ 230 60 1550 5 26 0.17 -30 to +40 0.9 76 42 15

C 1~ 230 50 1300 7 31 0.20 -30 to +40


M4Q 045-CA01 -01 B D 1~ 230 60 1550 8 30 0.20 -30 to +40 1.1 82 42 15

E 1~ 230 50 1300 10 36 0.25 -30 to +40


M4Q 045-CA03 -51 C F 1~ 230 60 1550 9 34 0.22 -30 to +40 1.2 82 42 15

G 1~ 230 50 1300 16 60 0.42 -30 to +40


M4Q 045-CF01 -01 D H 1~ 230 60 1550 16 58 0.36 -30 to +40 1.3 87 42 15

I 1~ 230 50 1300 18 70 0.48 -30 to +40


M4Q 045-DA01 -01 (1) E J 1~ 230 60 1550 18 62 0.42 -30 to +40 1.6 93 54 15

K 1~ 230 50 1300 23 86 0.62 -30 to +40


M4Q 045-DA05 -01 (1) F L 1~ 230 60 1550 25 80 0.55 -30 to +40 1.6 93 54 15

M 1~ 230 50 1300 25 90 0.62 -30 to +40


M4Q 045-EA01 -01 (1) G N 1~ 230 60 1550 26 80 0.55 -30 to +40 2.0 103 59 16

O 1~ 230 50 1300 34 110 0.75 -30 to +40


M4Q 045-EF01 -01 (1) H P 1~ 230 60 1550 34 100 0.65 -30 to +40 2.2 125 79 33

subject to alterations (1) Foot mounting possible on A or B side

83 F ±2
67 B
58
 Direction of rotation

K
Ø25,4
Ø3,6

Ø41
71,4

ØD
51

M4
H
450

B side A side
1,5 E ±2

C
26 G ±2

Foot measure  "V" "A" 

302
Axial impeller Guard grille Basket guard grille Wall ring Mounting bracket
p. 377 p. 378 p. 378 p. 379 p. 380
information
General
AC axial fans
Valid for all designs:
– Material: Housing made of die-cast aluminium – Mounting: Guard grille and wall ring are mounted onto the protruding
Stator pack: Coated in black thread ends of the A side. The Q-motor can also be screwed on via the
– Direction of air flow: "V" or "A" (depending on axial impeller used) mounting flanges (integrated in the bearing shields).
– Direction of rotation: Counter-clockwise, seen on shaft end – Axial impeller mounting: Mounted to the motor shaft using a plastic
– Insulation class: "B" adapter with pulling peg and an M4 screw (combination A-D) or M5

AC axial
S series
– Mounting position: Any, preferrably horizontal (combination E-H) screw.
– Condensate discharges: None – Power specifications: At 60 Hz, the blade angle of the axial impellers
– Mode of operation: Continuous operation (S1) must be reduced by 6° each.
– Bearing: Self-adjusting calotte sleeve bearing (mean service life of
30,000 hours in horizontal installation position)
– Motor protection: Impedance protection (combination A-C) or thermal

AC axial
K series
overload protector internally switched (combination D-H)
– Protection class: I

AC axial
A series
Axial impellers Blade angle 22° ± 1°30´ Blade angle 28° ± 1°30´ Blade angle 34° ± 1°30´

ØD H F G C m /h (2)
3
F G C m /h (2)
3
F G C m3/h (2)

EC axial fans
154 90 61 56 27.5 60 56 59 32.0 100 54 62 37.0 140
172 103 58 57 31.0 120 55 59 36.0 180 53 63 42.0 230
200 123 58 58 32.0 190 55 60 37.5 300 — — — —
200 123 65 58 32.0 190 62 60 37.5 300 59 64 45.0 400
230 123 64 62 35.0 500 — — — — — — — —

EC axial
S series
230 123 64 62 35.0 500 60 65 43.0 630 52 68 50.0 820
254 135 64 62 37.0 580 — — — — — — — —

254 135 70 62 37.0 580 65 66 45.0 840 — — — —

254 135 76 74 37.0 580 72 78 45.0 840 67 80 52.0 1070

Q-motor
300 160 75 79 43.0 1000 — — — — — — — —

300 160 75 79 43.0 1000 67 81 53.5 1400 — — — —

300 160 86 84 43.0 1000 77 86 53.5 1400 — — — —

ESM
300 160 108 104 43.0 1000 104 106 53.5 1400 95 112 61.0 1700

(2) established at counterpressure of 20 Pa


EC-SYSTEMS
Accessories
Technology
Contacts

303
Square shaded-pole motors
Multi-function design

– Foot mounting: Track dimension 26 mm (height 51 mm) or 18 mm (height 48 mm)


possible
– Bearing shields: A and B-sides, tapped holes 3 x M4, diameter of pitch circle 71.4 mm;
mounting of guard grille and wall ring on A-side bearing shield;
opposite M4 are securely installed in the feet
(knurled hex nuts are not included in delivery scope)
– Type of protection: IP 42
– Electrical connection: Jacketed cable 3 x 0.5 mm2 with brass lead tips
– Product conforming to standard: CE
– Approvals: VDE
– Curves: Page 308
Motor axial impeller

Perm. amb. temp.


Nominal voltage
Combination:

Power output

Current draw
Power input
Speed/rpm
Frequency
Curve

Mass
Nominal data Dimensions
Type p.302 VAC Hz rpm W W A °C kg A B E F K

A 1~ 230 50 1300 5 29 0.19 -30 to +40


M4Q 045-BD01 -75 A B 1~ 230 60 1550 5 26 0.17 -30 to +40 0.9 43 76 43.5 12 15.0
C 1~ 230 50 1300 7 31 0.20 -30 to +40
M4Q 045-CA01 -75 B D 1~ 230 60 1550 8 30 0.20 -30 to +40 1.1 49 82 43.5 10 15.0
E 1~ 230 50 1300 10 36 0.25 -30 to +40
M4Q 045-CA03 -75 C F 1~ 230 60 1550 9 34 0.22 -30 to +40 1.2 49 82 43.5 10 15.0
G 1~ 230 50 1300 16 60 0.42 -30 to +40
M4Q 045-CF01 -75 D H 1~ 230 60 1550 16 58 0.36 -30 to +40 1.3 54 87 43.5 10 15.0
I 1~ 230 50 1300 18 70 0.48 -30 to +40
M4Q 045-DA01 -75 E J 1~ 230 60 1550 18 62 0.42 -30 to +40 1.6 59 93 43.5 10 15.0
K 1~ 230 50 1300 23 86 0.62 -30 to +40
M4Q 045-DA05 -75 F L 1~ 230 60 1550 25 80 0.55 -30 to +40 1.6 59 93 43.5 10 15.0
M 1~ 230 50 1300 25 90 0.62 -30 to +40
M4Q 045-EA01 -75 G N 1~ 230 60 1550 26 80 0.55 -30 to +40 2.0 69 103 44.0 10 15.5
O 1~ 230 50 1300 34 110 0.75 -30 to +40
M4Q 045-EF01 -75 H P 1~ 230 60 1550 34 100 0.65 -30 to +40 2.2 92 125 61.0 10 33.0
subject to alterations

26 Foot measure
E ±2 M4
3x120° B side K A side M4
11,5
Ø3,6
51
M4
M4

71,4
Ø25,4

71,4
48
1500

M4

M4
M4 (4x)
13

M4 F
85

M4 A 3x120°
18 B
Foot measure 67
83

304
Axial impeller Guard grille Basket guard grille Wall ring Mounting bracket
p. 377 p. 378 p. 378 p. 379 p. 380
information
General
Square shaded-pole motors
Frigo design (specially for spare parts requirements)

AC axial fans
– Foot mounting: Track dimension 18 mm (height 48 mm)
– Bearing shields: B-side, tapped holes 3 x M4, diameter of pitch circle 71.4 mm;
mounting of guard grille and wall ring on A-side bearing shield;
M4 knurled hex nuts (2x) are enclosed in loose form
– Type of protection: IP 42

AC axial
S series
– Electrical connection: Jacketed cable 3 x 0.5 mm2 with brass lead tips
– Product conforming to standard: CE
– Approvals: VDE
– Curves: Page 308

AC axial
K series
Motor axial impeller

Perm. amb. temp.


Nominal voltage
Combination:

AC axial
A series
Power output

Current draw
Power input
Speed/rpm
Frequency
Curve

Mass
Nominal data Dimensions
Type p.302 VAC Hz rpm W W A °C kg A B F K

EC axial fans
A 1~ 230 50 1300 5 29 0.19 -30 to +40
M4Q 045-BD01 -A4 A B 1~ 230 60 1550 5 26 0.17 -30 to +40 0.9 48.5 76 12 15
C 1~ 230 50 1300 7 31 0.20 -30 to +40
M4Q 045-CA01 -N4 B D 1~ 230 60 1550 8 30 0.20 -30 to +40 1.1 48.5 82 10 15
E 1~ 230 50 1300 10 36 0.25 -30 to +40
M4Q 045-CA03 -A4 C F 1~ 230 60 1550 9 34 0.22 -30 to +40 1.2 48.5 82 10 15
G 1~ 230 50 1300 16 60 0.42 -30 to +40

EC axial
S series
M4Q 045-CF01 -A4 D H 1~ 230 60 1550 16 58 0.36 -30 to +40 1.3 48.5 87 10 15
I 1~ 230 50 1300 18 70 0.48 -30 to +40
M4Q 045-DA01 -A4 E J 1~ 230 60 1550 18 62 0.42 -30 to +40 1.6 48.5 93 10 15
K 1~ 230 50 1300 23 86 0.62 -30 to +40
M4Q 045-DA05 -A4 F L 1~ 230 60 1550 25 80 0.55 -30 to +40 1.6 48.5 93 10 15
M 1~ 230 50 1300 25 90 0.62 -30 to +40
M4Q 045-EA01 -A4 G N 1~ 230 60 1550 26 80 0.55 -30 to +40 2.0 49.0 103 10 16

Q-motor
O 1~ 230 50 1300 34 110 0.75 -30 to +40
M4Q 045-EF01 -A4 H P 1~ 230 60 1550 34 100 0.65 -30 to +40 2.2 66.0 125 10 33
subject to alterations

71,4

ESM
B side A side
K M4
20°
3x1
Ø3,6
Ø25,4

1500
EC-SYSTEMS

85
M4
48

M4
M4(4x)
13

Accessories

F M4
A 18
B Foot measure 67
83
Technology
Contacts

305
Axial impeller Guard grille Basket guard grille Wall ring Mounting bracket
p. 377 p. 378 p. 378 p. 379 p. 380
Square shaded-pole motors
Plug terminal design

– Foot mounting: Track dimension 26 mm (height 51 mm)


– Type of protection: IP 42
– Electrical connection: Rast 5.6 mm terminal connector, 2.8 x 0.5 mm blade terminal;
connection lines available in 420 mm to 4970 mm lengths
– Product conforming to standard: CE
– Approvals: VDE (put into operation with ebm-papst connection line only!)
– Curves: Page 308
Motor axial impeller

Perm. amb. temp.


Nominal voltage
Combination:

Power output

Current draw
Power input
Speed/rpm
Frequency
Curve

Mass
Nominal data Dimensions
Type p.302 VAC Hz rpm W W A °C kg B E F K

A 1~ 230 50 1300 5 29 0.19 -30 to +40


M4Q 045-BD01 -08 A B 1~ 230 60 1550 5 26 0.17 -30 to +40 0.9 76 43.5 12 15
C 1~ 230 50 1300 7 31 0.20 -30 to +40
M4Q 045-CA01 -08 B D 1~ 230 60 1550 8 30 0.20 -30 to +40 1.1 82 43.5 10 15
E 1~ 230 50 1300 10 36 0.25 -30 to +40
M4Q 045-CA03 -08 C F 1~ 230 60 1550 9 34 0.22 -30 to +40 1.2 82 43.5 10 15
G 1~ 230 50 1300 16 60 0.42 -30 to +40
M4Q 045-CF01 -08 D H 1~ 230 60 1550 16 58 0.36 -30 to +40 1.3 87 43.5 10 15
I 1~ 230 50 1300 18 70 0.48 -30 to +40
M4Q 045-DA01 -52 (1) E J 1~ 230 60 1550 18 62 0.42 -30 to +40 1.6 93 43.5 10 15
K 1~ 230 50 1300 23 86 0.62 -30 to +40
M4Q 045-DA05 -52 (1) F L 1~ 230 60 1550 25 80 0.55 -30 to +40 1.6 93 43.5 10 15
M 1~ 230 50 1300 25 90 0.62 -30 to +40
M4Q 045-EA01 -52 (1) G N 1~ 230 60 1550 26 80 0.55 -30 to +40 2.0 103 44.0 10 16
O 1~ 230 50 1300 34 110 0.75 -30 to +40
M4Q 045-EF01 -52 (1) H P 1~ 230 60 1550 34 100 0.65 -30 to +40 2.2 125 61.0 10 33
subject to alterations (1) Foot mounting possible on A or B side

14,5
9 B side K A side
Blade terminal
2.8 x 0.5 mm
Ø3,6
Ø25,4

Rast 5.6 mm
18
20

51

PE
According to VDE, motor
M4(4x)

must be put into operation


with ebm-papst connection M4 5 F
11,5

line only!
26 9 E
Foot measure 67 B
83

306
Connection lead Axial impeller Guard grille Basket guard grille Wall ring Mounting bracket
p. 376 p. 377 p. 378 p. 378 p. 379 p. 380
information
General
Square shaded-pole motors
UL and CSA design

AC axial fans
– Description: Designs with UL/CSA approvals; connection lines, temperature monitor and
dynamo wire are UL/CSA-approved components
– Foot mounting: Track dimension 26 mm (height 51 mm)
– Type of protection: IP 42
– Electrical connection: Jacketed cable 3 x AWG20 with brass lead tips

AC axial
S series
– Product conforming to standard: UL547, UL1004, CSA C22.2 No. 100,
CSA C22.2 No. 77, CE
– Approvals: UL, CSA
– Curves: Page 308
– Drawing: See standard design on page 302

AC axial
K series
Motor axial impeller

Perm. amb. temp.


Nominal voltage
Combination:

AC axial
A series
Power output

Current draw
Power input
Speed/rpm
Frequency
Curve

Mass
Nominal data Dimensions
Type p.302 VAC Hz rpm W W A °C kg B E K

EC axial fans
A 1~ 115 50 1300 5 29 0.38 -30 to +40
M4Q 045-BD03 -04 (2) A B 1~ 115 60 1550 5 26 0.35 -30 to +40 0.9 76 42 15
A 1~ 230 50 1300 5 29 0.19 -30 to +40
M4Q 045-BD01 -04 (2) A B 1~ 230 60 1550 5 26 0.17 -30 to +40 0.9 76 42 15
C 1~ 115 50 1300 7 31 0.40 -30 to +40
M4Q 045-CA17 -04 (2) B D 1~ 115 60 1550 8 30 0.40 -30 to +40 1.1 82 42 15
C 1~ 230 50 1300 7 31 0.20 -30 to +40

EC axial
S series
M4Q 045-CA01 -04 (2) B D 1~ 230 60 1550 8 30 0.20 -30 to +40 1.1 82 42 15
E 1~ 115 50 1300 10 36 0.50 -30 to +40
M4Q 045-CA27 -04 (2) C F 1~ 115 60 1550 9 34 0.45 -30 to +40 1.2 82 42 15
E 1~ 230 50 1300 10 36 0.25 -30 to +40
M4Q 045-CA25 -04 (2) C F 1~ 230 60 1550 9 34 0.22 -30 to +40 1.2 82 42 15
G 1~ 115 50 1300 16 60 0.80 -30 to +40
M4Q 045-CF07 -04 (2) D H 1~ 115 60 1550 16 58 0.74 -30 to +40 1.3 87 42 15

Q-motor
G 1~ 230 50 1300 16 60 0.42 -30 to +40
M4Q 045-CF01 -04 (2) D H 1~ 230 60 1550 16 58 0.36 -30 to +40 1.3 87 42 15
I 1~ 115 50 1300 18 70 0.98 -30 to +40
M4Q 045-DA11 -04 (1)(3) E J 1~ 115 60 1550 18 62 0.87 -30 to +40 1.6 93 54 15
I 1~ 230 50 1300 18 70 0.48 -30 to +40
M4Q 045-DA01 -04 (1)(3) E J 1~ 230 60 1550 18 62 0.42 -30 to +40 1.6 93 54 15
K 1~ 115 50 1300 23 86 1.25 -30 to +40
M4Q 045-DA13 -04 (1)(3) F 1.6 93 54 15

ESM
L 1~ 115 60 1550 25 80 1.10 -30 to +40
K 1~ 230 50 1300 23 86 0.62 -30 to +40
M4Q 045-DA05 -04 (1)(3) F L 1~ 230 60 1550 25 80 0.55 -30 to +40 1.6 93 54 15
M 1~ 115 50 1300 25 90 1.25 -30 to +40
M4Q 045-EA03 -04 (1)(3) G N 1~ 115 60 1550 26 80 1.10 -30 to +40 2.0 103 59 16 EC-SYSTEMS
M 1~ 230 50 1300 25 90 0.62 -30 to +40
M4Q 045-EA01 -04 (1)(3) G N 1~ 230 60 1550 26 80 0.55 -30 to +40 2.0 103 59 16
O 1~ 115 50 1300 34 110 1.50 -30 to +40
M4Q 045-EF03 -04 (1)(3) H P 1~ 115 60 1550 34 100 1.35 -30 to +40 2.2 125 79 33
O 1~ 230 50 1300 34 110 0.75 -30 to +40
M4Q 045-EF01 -04 (1)(3) H P 1~ 230 60 1550 34 100 0.65 -30 to +40 2.2 125 79 33
subject to alterations (1) A and B-side foot mounting possible (2) File No. E 171165 (3) File No. E 76226
Accessories
Technology
Contacts

307
Axial impeller Guard grille Basket guard grille Wall ring Mounting bracket
p. 377 p. 378 p. 378 p. 379 p. 380
Square shaded-pole motors
Air performance curves (measured in wall ring)

M4Q045-BD01-**, Ø 154, 50 Hz M4Q045-BD01-**, Ø 154, 60 Hz


[Pa]

[Pa]
A B

90 90

80 80

70 70

60 60

50 50

40 40

30 30

20 20

10 10

50 100 150 200 250 [m3/h] 50 100 150 200 250 [m3/h]

22° 28° 34° 22° 28° 34°

M4Q045-BD01-**, Ø 172, 50 Hz M4Q045-BD01-**, Ø 172, 60 Hz


[Pa]

[Pa]

A B

70
50

60

40
50

30 40

30
20

20

10
10

50 100 150 200 250 300 [m3/h] 50 100 150 200 250 300 350 [m3/h]

22° 28° 34° 22° 28° 34°

308
information
General
AC axial fans
M4Q045-BD01-**, Ø 200, 50 Hz M4Q045-BD01-**, Ø 200, 60 Hz

[Pa]
[Pa]

A B

AC axial
S series
50

50

40
40

AC axial
K series
30
30

20
20

AC axial
A series
10 10

EC axial fans
50 100 150 200 250 300 350 [m3/h] 50 100 150 200 250 300 350 400 [m3/h]

22° 28° 22° 28°

EC axial
S series
M4Q045-CA01-**, Ø 200, 50 Hz M4Q045-CA01-**, Ø 200, 60 Hz
[Pa]
[Pa]

C D

70 70

Q-motor
60 60

50 50

40 40

ESM
30 30
EC-SYSTEMS

20 20

10 10
Accessories

100 200 300 400 [m3/h] 100 200 300 400 [m3/h]

22° 28° 34° 22° 28° 34°


Technology
Contacts

309
Square shaded-pole motors
Air performance curves (measured in wall ring)

M4Q045-CA01-**, Ø 230, 50 Hz M4Q045-CA01-**, Ø 230, 60 Hz

[Pa]
[Pa]

C D

40

60

50 30

40

20
30

20
10

10

100 200 300 400 [m3/h] 100 200 300 400 500 [m3/h]

22° 22°

M4Q045-CA03-**, Ø 230, 50 Hz M4Q045-CA03-**, Ø 230, 60 Hz


[Pa]

[Pa]

E F
60
80

70 50

60
40

50

30
40

30
20

20

10
10

100 200 300 400 500 600 700 [m3/h] 100 200 300 400 500 600 700 [m3/h]

22° 28° 34° 22° 28° 34°

310
information
General
AC axial fans
M4Q045-CA03-**, Ø 254, 50 Hz M4Q045-CA03-**, Ø 254, 60 Hz

[Pa]
[Pa]

E F

AC axial
S series
35
60

30
50

25

AC axial
K series
40

20

30
15

AC axial
A series
20
10

10
5

EC axial fans
100 200 300 400 500 600 [m3/h] 100 200 300 400 500 600 700 [m3/h]

22° 22°

EC axial
S series
M4Q045-CF01-**, Ø 254, 50 Hz M4Q045-CF01-**, Ø 254, 60 Hz
[Pa]
[Pa]

G H

100
80

Q-motor
80

60

60

ESM
40

40
EC-SYSTEMS

20
20
Accessories

200 400 600 800 [m3/h] 200 400 600 800 [m3/h]

22° 28° 22° 28°


Technology
Contacts

311
Square shaded-pole motors
Air performance curves (measured in wall ring)

M4Q045-DA01-**, Ø 254, 50 Hz M4Q045-DA01-**, Ø 254, 60 Hz


[Pa]

[Pa]
I J

100

100

80

80

60
60

40
40

20
20

200 400 600 800 [m3/h] 200 400 600 800 1000 [m3/h]

22° 28° 34° 22° 28° 34°

I M4Q045-DA01-** / K -DA05-**, Ø 300, 50 Hz J M4Q045-DA01-** / L -DA05-**, Ø 300, 60 Hz


[Pa]

[Pa]

100

40

80

K 30
60
I

20 J
40

10
20

200 400 600 800 1000 1200 [m3/h] 200 400 600 800 1000 1200 [m3/h]

22° 22°

312
information
General
AC axial fans
M4Q045-EA01-**, Ø 300, 50 Hz M4Q045-EA01-**, Ø 300, 60 Hz

[Pa]
[Pa]

M N

50

AC axial
S series
100

40

80

AC axial
K series
30
60

20
40

AC axial
A series
10
20

EC axial fans
200 400 600 800 1000 1200 [m3/h] 200 400 600 800 1000 1200 1400 [m3/h]

22° 22°

EC axial
S series
M4Q045-EF01-**, Ø 300, 50 Hz M4Q045-EF01-**, Ø 300, 60 Hz
[Pa]

[Pa]

O P

80
100

Q-motor
80 60

60

ESM
40

40 EC-SYSTEMS

20
20
Accessories

400 800 1200 1600 [m3/h] 400 800 1200 1600 [m3/h]

22° 28° 34° 22° 28° 34°


Technology
Contacts

313
314
Air performance curves

Energy-saving axial fans


Energy-saving motors (ESM)
Energy-saving motors (ESM)

315
326
320
316

Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
Energy-saving motors (ESM)

– Material: Housing made of die-cast aluminium


Rotor: Coated in black
– Direction of air flow: "V" or "A" (depending on axial impeller used)
– Direction of rotation: Counter-clockwise, seen on shaft end
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Perm. amb. temp.


Nominal voltage

Lower speed (1)


Upper speed (1)

Power output
Power input
Frequency
Curve

Mass
Nominal data
Type VAC Hz rpm rpm W W °C kg

M1G 055-BD95 -12 A 1~ 115

50/60 2200 1500 22.0 15.0 -30 to +50 0.9

M1G 055-BD91 -12 A 1~ 230

M1G 055-BD95 -16 B 1~ 115

50/60 1750 1300 22.0 12.5 -30 to +50 0.9

M1G 055-BD91 -16 B 1~ 230

M1G 055-BD95 -21 C 1~ 115

50/60 1550 1100 21.0 10.4 -30 to +50 0.9

M1G 055-BD91 -21 C 1~ 230

subject to alterations (1) preprogrammed speeds

Including line cord with


plug (450 mm long)
 Direction of rotation

B side A side

Fastening thread M4  "V" "A" 

316
Connection lead Programming Axial impeller (Basket) guard grille Wall ring Mounting angle
p. 374 device p. 375 p. 377 p. 378 p. 379 p. 381
information
General
AC axial fans
– Motor protection: Via electronics – Speed settings: The pre-programmed upper speed is reached
– Electrical connection: Line cord with plug with the speed relay open; lower speed is reached when the speed
– Protection class: II relay is closed.
– Product conforming to standard: CE Speeds from 10% to 100% of the maximum speed can be preset
– Approvals: VDE, UL using the programming unit (see page 375). However, we recommend

AC axial
S series
– Curves: Page 320 not allowing it to fall below 1000 rpm ( A B C ).
– Mounting: Guard grille and wall ring are mounted onto the protruding
thread ends of the A side.
– Axial impeller mounting: Mounted to the motor shaft using a plastic
adapter with pulling peg and an M4 screw.

AC axial
K series
AC axial
A series
Axial impellers Blade angle 22° ± 1°30´ Blade angle 28° ± 1°30´ Blade angle 34° ± 1°30´

ØD rpm m /h (2)
3
W (3) F C m /h (2)
3
W (3) F C m /h (2)
3
W (3) F C

EC axial fans
2200 250 4.0 310 5.3 350 6.7
154 74.0 27.5 71.5 32.0 69.0 37.0
1500 170 1.3 210 1.7 240 2.1
2200 380 7.0 440 10.0 500 13.6
172 72.0 31.0 69.5 36.0 66.5 42.0
1500 260 2.2 300 3.2 340 4.3
2200 560 13.4 640 (4)19.5

EC axial
S series
200 71.5 32.0 69.0 37.5
1500 380 4.3 435 6.2
1750 200 2.0 250 2.7 280 3.4
154 74.0 27.5 71.5 32.0 69.0 37.0
1300 150 1.3 215 1.7 240 2.1
1750 300 3.5 350 5.0 400 6.8
172 72.0 31.0 69.5 36.0 66.5 42.0
1300 225 2.2 300 3.2 345 4.3

Q-motor
1750 450 6.7 510 9.9 620 (4)16.8
200 71.5 32.0 69.0 37.5 65.0 45.0
1300 335 4.2 440 6.2 530 10.6
1550 180 1.4 220 1.9 240 2.3
154 74.0 27.5 71.5 32.0 69.0 37.0
1100 130 0.5 155 0.7 170 0.8
1550 270 2.5 310 3.5 350 4.8
172 72.0 31.0 69.5 36.0 66.5 42.0

ESM
1100 190 0.9 220 1.3 250 1.7
1550 400 4.7 450 6.9 550 (4)12.7
200 71.5 32.0 69.0 37.5 65.0 45.0
1100 285 1.7 320 2.5 390 4.5
1550 710 (4)15.4
EC-SYSTEMS
230 70.0 35.0
1100 505 6.0
(2) Running at free air flow (3) Power requirement of impeller (4) Permitted with corresponding cooling of the motor (shaft power > output power)

– Electr.
Accessories

connection: black L1 1

Power system: 115 or 230 VAC, blue N 2


50/60 Hz Energy-
saving
Speed selection motor
5 (ESM)
Technology

brown

115 or 230 VAC


L or N
Contacts

317
Energy-saving motors (ESM)

– Material: Housing made of die-cast aluminium


Rotor: Coated in black
– Direction of air flow: "V" or "A" (depending on axial impeller used)
– Direction of rotation: Counter-clockwise, seen on shaft end
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Perm. amb. temp.


Nominal voltage

Lower speed (1)


Upper speed (1)

Power output
Power input
Frequency
Curve

Mass
Nominal data
Type VAC Hz rpm rpm W W °C kg

M1G 055-BD91 -45 D 1~ 115

50/60 1400 1000 9.0 5.9 -30 to +50 0.9

M1G 055-BD87 -25 D 1~ 230

M1G 055-BD95 -26 E 1~ 115


50/60 1400 1000 27.0 12.0 -30 to +50 0.9
M1G 055-BD91 -26 E 1~ 230

M1G 055-BD91 -17 F 1~ 115

50/60 1200 800 12.0 7.5 -30 to +50 0.9

M1G 055-BD87 -17 F 1~ 230

M1G 055-BD95 -30 G 1~ 115


50/60 1200 800 15.4 6.3 -30 to +50 0.9
M1G 055-BD91 -30 G 1~ 230

subject to alterations (1) preprogrammed speeds

Including line cord with plug


(450 mm long)
 Direction of rotation

B side A side

Fastening thread M4  "V" "A" 

318
Connection lead Programming Axial impeller (Basket) guard grille Wall ring Mounting angle
p. 374 device p. 375 p. 377 p. 378 p. 379 p. 381
information
General
AC axial fans
– Motor protection: Via electronics – Speed settings: The pre-programmed upper speed is reached
– Electrical connection: Line cord with plug with the speed relay open; lower speed is reached when the speed
– Protection class: II relay is closed.
– Product conforming to standard: CE Speeds from 10% to 100% of the maximum speed can be preset
– Approvals: VDE, UL using the programming unit (see page 375). However, we recommend

AC axial
S series
– Curves: Page 320 not allowing it to fall below 600 rpm ( D F ) or 1000 rpm ( E G ).
– Mounting: Guard grille and wall ring are mounted onto the protruding
thread ends of the A side.
– Axial impeller mounting: Mounted to the motor shaft using a plastic
adapter with pulling peg and an M4 screw.

AC axial
K series
AC axial
A series
Axial impellers Blade angle 22° ± 1°30´ Blade angle 28° ± 1°30´ Blade angle 34° ± 1°30´

ØD rpm m /h (2)
3
W (3) F C m /h (2)
3
W (3) F C m /h (2)
3
W (3) F C

EC axial fans
1400 160 1.0 200 1.3 220 1.7
154 74.0 27.5 71.5 32.0 69.0 37.0
1000 115 0.4 145 0.5 160 0.6
1400 240 1.8 280 2.5 320 3.5
172 72.0 31.0 69.5 36.0 66.5 42.0
1000 170 0.6 200 1.0 230 1.3
1400 360 3.4 410 5.0

EC axial
S series
200 71.5 32.0 69.0 37.5
1000 260 1.3 295 1.8
1400 500 8.6
200 65.0 45.0
1000 360 3.1
1400 640 11.0 700 (4)12.5 860 (4)14.7
230 70.0 35.0 66.0 43.0 62.5 50.0
1000 460 4.0 500 4.6 615 5.3

Q-motor
1200 140 0.6 170 0.8 190 1.1
154 74.0 27.5 71.5 32.0 69.0 37.0
800 95 0.2 110 0.2 130 0.3
1200 210 1.1 240 1.6 270 2.2
172 72.0 31.0 69.5 36.0 66.5 42.0
800 140 0.3 160 0.5 180 0.7
1200 310 2.1 350 3.2 420 5.4
200 71.5 32.0 69.0 37.5 65.0 45.0

ESM
800 210 0.6 235 1.0 290 1.6
1200 550 (4) 6.9 600 (4) 7.9 740 (4) 9.3
230 70.0 35.0 66.0 43.0 62.5 50.0
800 365 2.0 400 2.3 495 2.7
1200 610 (4)10.3
EC-SYSTEMS
254 69.0 37.0
800 405 3.0
(2) Running at free air flow (3) Power requirement of impeller (4) Permitted with corresponding cooling of the motor (shaft power > output power)

– Electr.
Accessories

connection: black L1 1

Power system: 115 or 230 VAC, blue N 2


50/60 Hz Energy-
saving
Speed selection motor
5 (ESM)
Technology

brown

115 or 230 VAC


L or N
Contacts

319
Energy-saving motors (ESM)
Air performance curves

Ø 154, 2200 rpm / 1500 rpm Ø 172, 2200 rpm / 1500 rpm

[Pa]
[Pa]

A A

50
35

30
40

25

30
20

15 20

10

10
5

50 100 150 200 250 300 350 [m3/h] 100 200 300 400 [m3/h]

2200 min-1: 22˚ 28˚ 34˚ 2200 min-1: 22˚ 28˚ 34˚
1500 min-1: 22˚ 28˚ 34˚ 1500 min-1: 22˚ 28˚ 34˚

Ø 200, 2200 rpm / 1500 rpm


[Pa]

40

30

20

10

100 200 300 400 500 [m3/h]

2200 min-1: 22˚ 28˚ 34˚


1500 min-1: 22˚ 28˚ 34˚

320
information
General
AC axial fans
Ø 154, 1750 rpm / 1300 rpm Ø 172, 1750 rpm / 1300 rpm
[Pa]

[Pa]
B B

24

AC axial
S series
30

20
25

16

AC axial
K series
20

12
15

AC axial
A series
10

4 5

EC axial fans
50 100 150 200 250 [m3/h] 50 100 150 200 250 300 350 [m3/h]

1750 min-1: 22˚ 28˚ 34˚ 1750 min-1: 22˚ 28˚ 34˚
1300 min-1: 22˚ 28˚ 34˚ 1300 min-1: 22˚ 28˚ 34˚

EC axial
S series
Ø 200, 1750 rpm / 1300 rpm
[Pa]

50

Q-motor
40

30

20 ESM
EC-SYSTEMS

10
Accessories

100 200 300 400 500 [m3/h]

1750 min-1: 22˚ 28˚ 34˚


1300 min-1: 22˚ 28˚ 34˚
Technology
Contacts

321
Energy-saving motors (ESM)
Air performance curves

Ø 154, 1550 rpm / 1100 rpm Ø 172, 1550 rpm / 1100 rpm
[Pa]

[Pa]
C C

25
16

20

12

15

10

4
5

40 80 120 160 200 [m3/h] 50 100 150 200 250 300 350 [m3/h]

1550 min-1: 22˚ 28˚ 34˚ 1550 min-1: 22˚ 28˚ 34˚
1100 min-1: 22˚ 28˚ 34˚ 1100 min-1: 22˚ 28˚ 34˚

Ø 200, 1550 rpm / 1100 rpm Ø 230, 1550 rpm / 1100 rpm
[Pa]

[Pa]

C C

40
35

30

30
25

20
20

15

10
10

100 200 300 400 500 [m3/h] 100 200 300 400 500 600 700 [m3/h]

1550 min-1: 22˚ 28˚ 34˚ 1550 min-1: 22˚ 28˚ 34˚
1100 min-1: 22˚ 28˚ 34˚ 1100 min-1: 22˚ 28˚ 34˚

322
information
General
AC axial fans
Ø 154, 1400 rpm / 1000 rpm Ø 172, 1400 rpm / 1000 rpm

[Pa]
[Pa]

D D
24

AC axial
S series
14

20
12

10 16

AC axial
K series
8
12

AC axial
A series
4

4
2

EC axial fans
40 80 120 160 200 [m3/h] 50 100 150 200 250 300 [m3/h]

1400 min-1: 22˚ 28˚ 34˚ 1400 min-1: 22˚ 28˚ 34˚
1000 min-1: 22˚ 28˚ 34˚ 1000 min-1: 22˚ 28˚ 34˚

EC axial
S series
Ø 200, 1400 rpm / 1000 rpm Ø 230, 1400 rpm / 1000 rpm
[Pa]
[Pa]

E
E

35
30

Q-motor
30
25

25
20
D
20

ESM
E
15
D
15

10
EC-SYSTEMS

D 10
D

5
5
Accessories

100 200 300 400 [m3/h] 200 400 600 800 [m3/h]

1400 min-1: 22˚ 28˚ 34˚ 1400 min-1: 22˚ 28˚ 34˚
1000 min-1: 22˚ 28˚ 34˚ 1000 min-1: 22˚ 28˚ 34˚
Technology
Contacts

323
Energy-saving motors (ESM)
Air performance curves

Ø 154, 1200 rpm / 800 rpm Ø 172, 1200 rpm / 800 rpm

[Pa]
[Pa]

F F

16

10
14

8 12

10
6
8

4 6

2
2

40 80 120 160 [m3/h] 50 100 150 200 250 [m3/h]

1200 min-1: 22˚ 28˚ 34˚ 1200 min-1: 22˚ 28˚ 34˚
800 min-1: 22˚ 28˚ 34˚ 800 min-1: 22˚ 28˚ 34˚

Ø 200, 1200 rpm / 800 rpm Ø 230, 1200 rpm / 800 rpm
[Pa]

[Pa]

F G

24 28

24
20

20
16

16

12

12

8
8

4
4

100 200 300 400 [m3/h] 100 200 300 400 500 600 700 [m3/h]

1200 min-1: 22˚ 28˚ 34˚ 1200 min-1: 22˚ 28˚ 34˚
800 min-1: 22˚ 28˚ 34˚ 800 min-1: 22˚ 28˚ 34˚

324
[Pa]

5
10
15
20

100
Ø 254, 1200 rpm / 800 rpm

200

800 min-1:
300
1200 min-1:
400

22˚
22˚
500

28˚
28˚
G

[m3/h]

34˚
34˚

325
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
Energy-saving axial fans

– Material: Wall ring: Plastic PP20TV – Mode of operation: Continuous operation (S1)
Blade: Sheet steel, coated in – Bearings: Maintenance-free ball bearings
black – Motor protection: Via electronics
Rotor: Coated in black – Electrical connection: Line cord with plug
– Number of blades: 5 – Protection class: II
– Direction of air flow: "V", exhaust over – Product conforming to standard: CE
struts – Approvals: VDE, UL, CSA
– Direction of rotation: Counter-clockwise, – Speed: Using the programming unit
seen on rotor (see page 375), 2 speeds
– Type of protection: IP 44 between nmin and nmax can be programmed.
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None

Max. operative range


Sound pressure level

Perm. amb. temp.


Nominal voltage

Current draw
Power input
Speed/rpm
Frequency

Air flow
Curve

Mass
Nominal data
Type Motor VAC Hz m3/h rpm W A dB(A) Pa °C kg

W1G200-EA91 -27 M1G 055-BD A 115 50/60 500 1400 7 0.12 42 — -30 to +50 1.0

W1G200-EA95 -47 M1G 055-BD B 115 50/60 800 2200 27 0.42 56 — -30 to +50 1.0

W1G200-EA87 -25 M1G 055-BD A 230 50/60 500 1400 7 0.06 42 — -30 to +50 1.0

W1G200-EA91 -45 M1G 055-BD B 230 50/60 800 2200 27 0.21 56 — -30 to +50 1.0
subject to alterations

Curves (programmable) Curves (programmable)


[Pa]

[in H O]
[Pa]

[in H O]

A B
2
2
0,20

0,4

50 100

40 80
0,15

0,3

30 60
0,10

0,2

20 40
0,05

0,1

10 20

0 50 100 150 200 250 300 [CFM] 0 100 200 300 400 [CFM]

100 200 300 400 500 [m3/h] 100 300 500 700 [m3/h]

n max. = 1400 min-1 n min. = 500 min-1 n max. = 2200 min-1 n min. = 800 min-1

326
information
General
AC axial fans
– Electr.
connection:
black L1 1

Power system: 115 or 230 VAC, blue N 2


50/60 Hz Energy-

AC axial
S series
saving
Speed selection motor
brown 5 (ESM)

115 or 230 VAC


L or N

AC axial
K series
AC axial
A series
EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories

 "V"
Technology

Including line cord with plug


(450 mm long)
Contacts

327
Connection lead Programming Mounting angle
p. 374 device p. 375 p. 381
328
information
General
EC-SYSTEMS

AC axial fans
Options 330

Switch power supplies 334

AC axial
S series
External commutation electronics for rail technology 338

Accessories: Temperature sensor / control module, pressure control, selection module, interface converter, ... 340

HMS controller 358

AC axial
K series
AC axial
A series
EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

329
EC-SYSTEMS
Options

EC fan
EC fans 24 / 48 VDC
PWM and Lin 0-10 VDC
with integrated commutation electronics

red Linear input:


24 / 48 VDC < 1 VDC -> n=0
blue
1 VDC -> nmin
Control input Lin 0-10 VDC yellow 10 VDC -> nmax
PWM
PWM input:
white
< 10% PWM -> n=0
Tach output
10% PWM -> nmin
100% PWM -> nmax

Power supply 230 VAC / 48 VDC EC fan 48 VDC


EC fans 48 VDC
PWM and Lin 0-10 VDC
with integrated commutation electronics

red Linear input:


230 VAC, 50 / 60 Hz
< 1 VDC -> n=0
blue 1 VDC -> nmin
yellow 10 VDC -> nmax
Optional board (built-in):
PWM input:
white
< 10% PWM -> n=0
10% PWM -> nmin
Selector switch 3 speed steps
100% PWM -> nmax

Control input Lin 0-10 VDC or


Constant air flow
selector switch

PC with interface
converter (RS485) RS485 / ebmBUS

Commutation electronics 650 W EC fan


EC fans
with external commutation electronics
650 W, 110 VDC (rail technology)
110 VDC

PC with interface
converter (RS485)

Actual value 0-10 VDC


(e.g. pressure, temperature, air flow,
air speed, moisture, CO2)

Control input Lin 0-10 VDC


Potentiometer for set values

Tach output

Alarm

Controller enabling 10-100 VDC


10-253 VAC

330
information
General
AC axial fans
EC fan with integrated electronics
EC fans (motor size 055)
with integrated commutation electronics
1~ 115 VAC or 230 VAC
50/60 Hz mains operation

AC axial
S series
EC fans (motor size 074)
Mains operation, 50 / 60 Hz with integrated commutation electronics
1~ 100 -130 VAC or 200 -277 VAC
50/60 Hz mains operation

AC axial
K series
PC with interface
converter (RS485)

Control input 0-10 VDC / PWM


Actual value input 0-10 VDC

AC axial
A series
Supply for potentiometer 10 V

Tach output

EC axial fans
Slave output

EC fan with integrated electronics


EC fans (motor size 084)
with integrated commutation electronics
1~ 100 -130 VAC or 200 -277 VAC

EC axial
S series
50/60 Hz mains operation

Mains operation, 50 / 60 Hz

Q-motor
PC with interface
converter (RS485)

Control input 0-10 VDC / PWM

ESM
Actual value input 0-10 VDC

Supply for potentiometer 10 V


EC-SYSTEMS
Alarm

Slave output
Accessories
Technology
Contacts

331
EC-SYSTEMS
Options

EC fan with integrated electronics


EC fans (motor size 084, ebmBUS)
with integrated commutation electronics
1~ 200-277 VAC,
50/60 Hz mains operation

Mains operation, 50 / 60 Hz

PC with interface
converter (RS485)

On/off and alarm


output 15 V

EC fan with integrated electronics


EC fans (motor size 112/150)
with integrated commutation electronics
1~ 200-277 VAC or
3~ 200-240 / 380-480 VAC
50/60 Hz mains operation

Mains operation, 50 / 60 Hz

PC with interface
converter (RS485)

Control input 0-10 VDC / PWM


Actual value input 0-10 VDC

Actual value input 4-20 mA

Supply for external sensor 20 V

Supply for potentiometer 10 V

Alarm

Slave output

332
information
General
AC axial fans
Customer PC with LISA Interface converter Electronics EC fan
EC-SYSTEMS:
5.1 control software and repeater Networked EC fans with interface
converter and repeater
Control software
part no.
25711-2-0199

AC axial
S series
integrated electronics

Interface converter
part no. 21487-1-0174

AC axial
K series
max. 31
Features of control addresses
software LISA 5.1
Power supply 150 W
– Individual control
and monitoring of Repeater
max. 7,905 fans part no.
25708-1-0174

AC axial
A series
– Group-oriented
arrangement of the fans
– Level 1: Overview
display for 10 floors
max. 31
– Level 2: Overview addresses
display for 255 groups

EC axial fans
integrated electronics
– Level 3: Overview
display for 31 fans
within a group
– Broadcast command for
a group or all fans
– Speed, temperature or
pressure control

EC axial
S series
– Alarm signal

integrated electronics

Q-motor
Repeater
max. 31
addresses

ESM
EC-SYSTEMS
Accessories
Technology
Contacts

333
Switch power supply with PFC, basic version
48 VDC, 150 W / 300 W

– General remarks: Switch power supply with an output power of 150 W / 300 W to supply
48 VDC EC motors from the 115 / 230 VAC mains. It is also possible to run several motors
up to an overall power of 150 W / 300 W. Data on the 60 W switching power supply is
available on request.
– Function: Supply of an electrically insulated direct voltage of 48 VDC at the output when
connected to the 115 / 230 V mains. The power supply is sustainably short-circuit proof,
open-circuit proof and protected against overheating. An integrated EMC filter guarantees
RFI suppression of the unit according to EN 61000-3-2.
– Material: Housing made of stainless steel
– Protection class: I
– Type of protection: IP 20 (acc. to EN 60529)

Rated output current


Nominal voltage

Output voltage
Frequency

P1 max.
Output

Mass
Nominal data Dimensions
Type VAC Hz VDC W A kg a b c d e f

CNW015-AB06 -01 1~ 115 50/60 48 150 3.10 0.7 187 176 167 50 110 1
CNW015-AB02 -01 1~ 230 50/60 48 150 3.10 0.7 187 176 167 50 110 1
CNW030-AC06 -01 1~ 100-120 50/60 48 300 6.25 1.3 272 260 251 66 112 2
CNW030-AC02 -01 1~ 200-277 50/60 48 300 6.25 1.3 272 260 251 66 112 2
subject to alterations

– EMC: Interference emission acc. to EN 61000-6-3


Interference immunity acc. to EN 61000-6-1
d

– Product conforming to standards: EN 50178, CE


f

– Approvals: UL/CSA (File No. E 181381)


e

5
a
c
b

80
10

108

334
Line side

V L
N
PE
red
Motor side

blue
V
red
+48 GND +48 GND
blue
Blower 1
exhaust air
Blower 2
exhaust air

335
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
Switch power supply with PFC, RS485 and ebmBUS
48 VDC, 150 W / 300 W

– General remarks: Switch power supply with an output power of 150 W / 300 W to supply
48 VDC EC motors from the 115 / 230 VAC mains. It is also possible to run several motors
up to an overall power of 150 W / 300 W. Data on the 60 W switching power supply is
available on request.
– Function: Supply of an electrically insulated direct voltage of 48 VDC at the output when
connected to the 115 / 230 V mains. The power supply is sustainably short-circuit proof,
open-circuit proof and protected against overheating. An integrated EMC filter guarantees
RFI suppression of the unit according to EN 61000-3-2.
– Material: Housing made of stainless steel
– Protection class: I
– Type of protection: IP 20 (acc. to EN 60529)

Rated output current


Nominal voltage

Output voltage
Frequency

P1 max.
Output

Mass
Nominal data Dimensions
Type VAC Hz VDC W A kg a b c d e f

CNW015-AB06 -05 1~ 115 50/60 48 150 3.10 0.7 187 176 167 50 110 1
CNW015-AB02 -05 1~ 230 50/60 48 150 3.10 0.7 187 176 167 50 110 1
CNW030-AC06 -05 1~ 100-120 50/60 48 300 6.25 1.3 272 260 251 66 112 2
CNW030-AC02 -05 1~ 200-277 50/60 48 300 6.25 1.3 272 260 251 66 112 2
subject to alterations

– EMC: Interference emission acc. to EN 61000-6-3


Interference immunity acc. to EN 61000-6-1
d

– Product conforming to standards: EN 50178, CE


f

– Approvals: UL/CSA (File No. E 181381)


e – Technical features: Control board for RS485, ebmBUS and LISA functions
5
a
c
b

80
10

108

336
information
General
AC axial fans
Blower
RS232
RS485
Interface converter

AC axial
S series
To next switch

~
power supply
white yellow

AC axial
K series
Line side Motor side Tach PWM
RS485 RS485
2 x RJ45:
PIN 5 - RS B
PIN 6 - RS A

L N PE +48 GND +48 GND


V V

AC axial
A series
red blue

EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

337
External commutation electronics
for rail technology, 110 VDC, 650 W

– General remarks: For EC motors and fans with 3 cores and without integrated
commutation electronics
– Function: Commutation unit for three-core EC motors up to a power input of 650 W.
Various basic functions are integrated: open loop speed control, closed loop speed control,
RS485 interface. In combination with sensors, all control tasks as required in air technology
can be executed.
– Protection class: I
– Type of protection: IP 20 (acc. to DIN EN 60529)
– NB: Connected fans have to be designed for a rated voltage of 127 VDC!

Perm. amb. temp.


Nominal voltage

Current draw
Power input
P1 max.

Mass

Nominal data
Type VDC W A °C kg

CEG 485-HB50 -01 110 650 5.9 -25 to +40 2.0


subject to alterations

169 – EMC / EMI: Acc. to EN 50155 and EN 50121


– Legislation: Low voltage directive 73/23/EEC, VDE 0160/EN 50178
– Design:
• Motor output protected against short circuit phase to phase and conditionally
68
2,2

phase to earth
• 0-10 V input (Ri: 100 k)
190 • 0-10 V input (Ri: 100 k) for connection of external actual value input
• RS485 interface (ebmBUS)
• Floating alarm contact 250 VAC / 5A, during alarm, relay is released (low-active)
• Wide voltage input for external controller enabling via RESET function
• Tach output
1,5

179,5
• LED for operation and alarm mode
green: unit on
red: alarm
63

• Setting of minimum and maximum values via potentiometer


• Operational modes (to be set via DIP switch):
5,5

Open loop speed control


193

Closed loop speed control


64

Controlling external parameters


• Direction of motor rotation reversible
– Connectors for external electronics:
63

KL1 2-pole connector; centreline 7.5; Co. Wago part no.: 231-202/026-000
KL2A 6-pole connector; centreline 5; Co. Wago part no.: 231-106/026-000
KL2B 6-pole connector; centreline 5; Co. Wago part no.: 231-106/026-000
1,5
40

KL3A 2-pole connector; centreline 5; Co. Wago part no.: 231-102/026-000


KL3B 2-pole connector; centreline 5; Co. Wago part no.: 231-102/026-000
146,5 KL4 2-pole connector; centreline 5; Co. Wago part no.: 231-102/026-000
KL5A 5-pole connector; centreline 5; Co. Wago part no.: 231-105/026-000
KL5B 5-pole connector; centreline 5; Co. Wago part no.: 231-105/026-000
KL6 3-pole connector; centreline 7.5; Co. Wago part no.: 731-603

338
information
General
AC axial fans
AC axial
S series
AC axial
K series
KL2B KL3B KL5B
PE1 PE2
+18 Sensor
GND
+10 0-10
GND NC COM H+ TW
H+ PTC H- H-
V 1 V V

+ - RS RS RS RS An GND NO COM EN EN H1 H2 H3 U V W
A B A B + -

AC axial
A series
Tacho

KL1 KL2A KL3A KL4 KL5A KL6

EC axial fans
Connector Connection Assignment / function Connector Connection Assignment / function

EC axial
S series
PE1 Ground connection KL3A NO Relay contact for alarm, make for failure
PE2 Ground connection COM Relay contact for alarm
KL1 + 110 VDC KL3B NC Relay contact for alarm, break for failure
- 110 VDC COM Relay contact for alarm
KL2A RS A Interface connection RS A KL4 EN + Enable input via RESET function
RS B Interface connection RS B EN - Enable input via RESET function

Q-motor
RS A Interface connection RS A KL5A H1 Hall-sensor 1
RS B Interface connection RS B H2 Hall-sensor 2
An, Tacho Tach output, open collector H3 Hall-sensor 3
GND Reference KL2 (for KL2 only) Shielding connection
KL2B +18 V +18 V (non-stabilised, +20%, 20 mA) for supplying Shielding connection
external sensors KL5B H+ Power supply for hall-sensors (+)

ESM
Sensor 1 Input for external sensor, Ri = 100 k H+ Power supply for hall-sensors (+)
GND Reference KL2 (for KL2 only) TW / PTC Thermal switch or PTC connection
+10 V +10 V (stabilised +/- 3 %, 25 mA) H- Power supply for hall-sensors (-)
0-10 V Input for set value 0 - 10 V, Ri = 100 k H- Power supply for hall-sensors (-)
EC-SYSTEMS
GND Reference KL2 (for KL2 only) KL6 U Motor winding U
V Motor winding V
W Motor winding W
Accessories
Technology
Contacts

339
Temperature sensor

Output impedance

measuring range
Nominal voltage

Output voltage

Output current
Current draw

Temperature

Mass
Nominal data
Part no. VDC mA VDC mA k °C kg

50005-1-0174 15-30 10 0-10 1.0 1.1 -20 to +80 0.02


subject to alterations

3 +0,2
Ø7 +0,5
– Electr. connection:
1±0,1

Ø3,5
2,5

Ø4,9
3,3

red
8

15-30 VDC

84,7 yellow
0-10 VDC
45
output
37,5
6,5
13
5

6,9

38,5
450 +20

Output (yellow) Core-end sleeve


+ (red) blue
– (blue)
6
85

Temperature sensor

– Output voltage depending on temperature:


U/V
10

0
-20 80 Temp. °C

Tolerance ±3 K

340
information
General
Temperature control module

AC axial fans
AC axial
S series
AC axial
K series
Output impedance
Nominal voltage

Output voltage

Output current

AC axial
A series
control range
Current draw

Temperature

Mass
Nominal data
Part no. VDC mA VDC mA k °C kg

EC axial fans
50002-1-0174 18-60 10 2-10 0.1 6.8 +30 to +55 0.02
50003-1-0174 18-60 10 0-10 0.1 6.8 +10 to +45 0.02
subject to alterations

3 +0,2

EC axial
S series
Ø7 +0,5
– Electr. connection:
1±0,1

Ø3,5
2,5

Ø4,9
3,3

red red
8

18-60 VDC Maximum ripple


± 3.5 %

84,7 yellow yellow


2-10 VDC Control input 47 K
45

Q-motor
or 0-10 VDC 0 - 10 VDC
37,5 output Counter
Isink max.

47 K
6,5 10 mA
Controller
white
Tach output, 680 
13
5

Alarm pulses per revolution


6,9

38,5 Speed display


450 +20

47 V
Output (yellow) Core-end sleeve

ESM
+ (red) blue blue
– (blue) GND

6
85
EC-SYSTEMS

Temperature control module Connection Fans

– Control function: Both designs have "cooling" as control function


U/V U/V
10 10
Accessories

2
1

0 30 55 Temp. °C 0 6 10 45 Temp. °C
Technology

50002-1-0174 50003-1-0174
Tolerance ±3 K
Contacts

341
Pressure control with integrated pressure sensor

– Functions: Integrated PID controller, day/night/linear set point preset, integrated set point
potentiometer for day and night, external set point preset via potentiometer
– Pressure sensor: 0-500 Pa, bursting strength 200 mbar, for non-aggressive
gaseous media
– Type of protection: IP 55

Perm. amb. temp.


Nominal voltage,

Pressure control
voltage range

alternative
Frequency
Nominal

range

Nominal data
Type VAC Hz VDC Pa °C

CCC 000-AC04 -01 1~ 100-277 50/60 20 @ 50 mA 50-500 -25 to +60


subject to alterations

167
89,5
35,5

162
1,5
10,5

195
180±0,4
95±0,2
125

115

pressure controller IP55


43

100-277 VAC 50/60 Hz


pressure range 0-500 Pa
10

Ø 5,5
7,5

342
information
General
AC axial fans
Fan
Set value
potentiometer Selector switch

AC axial
S series
Day Linear
Night
Mains Alarm

AC axial
K series
20 V IN

0-10 V
+10 V

Night
PWM
COM

COM

Tach
GND

GND

GND

GND

GND
OUT

Day
NC

NC
PE

PE
N

N
L

ST1 ST2 ST7 ST8 ST3 ST4

AC axial
A series
Control terminals Line terminals

EC axial fans
Connector Connection Assignment / function Connector Connection Assignment / function

EC axial
S series
ST1 PE Protective earth ST3 20 V IN DC voltage supply (optional),
L Mains 50/60 Hz, phase with reverse polarity protection
N Mains 50/60 Hz, neutral GND GND
ST2 PE Protective earth ST4 Tach Tach output from fan
L Mains 50/60 Hz, phase OUT Control voltage for fan, 0-10 V
N Mains 50/60 Hz, neutral GND GND

Q-motor
ST7 NC Relay contact for alarm, break for failure +10 V Set value potentiometer,
COM Relay contact for alarm supply 10 V (-10 %), 10 mA
ST8 NC Relay contact for alarm, break for failure 0-10 V PWM Set value potentiometer
COM Relay contact for alarm GND Set value potentiometer
Day Selector switch terminal
GND Selector switch terminal

ESM
Night Selector switch terminal
GND Selector switch terminal

EC-SYSTEMS
Accessories
Technology
Contacts

343
Selection module for 3 speeds

– General remarks: Using an external selector switch, one of three preset speeds
can be chosen. Presetting is done via one integrated potentiometer each.
– Material: Plastics
– Type of protection: IP 20

Type

CBC 000-AE04 -01


subject to alterations

50
24
90

344
– Electr.
connection:

Selector switch

Day

Party
Night
+10 V
fan
red

blue

Connection
Connection

yellow

selector switch
GND
+10 V

0-10 V output
Fan

345
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
Interface converter RS232 - RS485

– General remarks: This interface converter permits bi-directional connection of


RS232 devices (laptop or PC) with ebmBUS devices (electronic commutation units with
RS485 interface)
– Safety: Electrical insulation between the RS232 and RS485 side is provided
– Material: Plastic housing for standard rail mounting according to DIN EN 50022-35
– Status display: Via LEDs
green: supply voltage OK
red: data exchange

no-load operation
Nominal voltage

Current draw at
Supply voltage

Mass (incl. PS)


power supply

Nominal data
Part no. VAC VAC / VDC mA kg

21487-1-0174 1~ 230 12-24 150 0.4


subject to alterations

RS232 RS485 – Mode of operation: RS485 2-wire mode with echo and automatic control
– Galvanic insulation: Min. 1kV insulation voltage between RS232 and RS485 interfaces and
22

between power supply and interfaces


– ESD immunity: Up to 15 kV (acc. to IEC 801-2, Stage 4)
– Delivery scope: • Interface converter
• Supply plug unit (230 VAC / 12 VDC, 500 mA)
• Adaptor leads with 2 x 9-pole SUB-D sockets
• Adaptor leads with 9-pole SUB-D socket
• Screw terminal RS485
105
M L+

75

346
information
General
Interface converter RS232 - RS485

AC axial fans
– General remarks: This interface converter permits bi-directional connection of
RS232 devices (laptop / PDA) with ebmBUS devices (electronic commutation units with
RS485 interface). Power supplied by RS232 of the laptop / PDA.
– Material: Plastic housing
– Status display: Via LEDs

AC axial
S series
PWR: Power supply
TXD: Data transfer (send)
RXD: Data transfer (receive)

AC axial
K series
AC axial
A series
Mass

Nominal data
Part no. kg

EC axial fans
21495-2-0174 0.1
subject to alterations

– Mode of operation: RS485 2-wire mode with echo and automatic control
TX+ TX- GND RX+ RX-
19

– Delivery scope: Interface converter, English-language operating manual

EC axial
S series
TRX+ TRX-
– Electrical terminals: Screw terminal, TRX+ = RSA, TRX– = RSB

Q-motor
RS422

RS485

74
RXD
TXD
PWR

ESM
37

EC-SYSTEMS
Accessories
Technology
Contacts

347
RS485 repeater

– General remarks: The physical RS485 repeater is used for the connection of two segments
on an RS485 basis. It can split a segment with network bus wires that are too long, or with
too many nodes into two smaller, standardised units. A maximum of 31 nodes can be
connected to the repeater.
– Installation: The repeater housing is mounted on the wall or in the cable duct with two
screws (Ø 4 mm) or with cable ties.
– Material: Housing made of galvanised sheet steel
– Type of protection: IP 20 according to DIN EN 60529

Perm. operating temp.

Perm. storage temp.


Supply voltage

Power input
Frequency

Mass
Nominal data
Part no. VAC Hz VA °C °C kg

25708-1-0174 1~ 200-277 50/60 <3 0 to +50 -20 to +70 0.3


subject to alterations

38 – Type of transceiver: 2 x ANSI standard RS485 transceiver


– Galvanic insulation: Operating insulation 500 V between both channels
– Network connection: Screw terminals
– Mains connection: Wieland connector GST 18/3 (part of delivery)
50

Bus2

Bus2

– Pin configuration of network:


Bus1

Bus1

Pin No. Assignment / function


Wieland Bamberg
Mating connector

1-4 not assigned


screw terminal

8765432 1 8765432 1
GST 18/3

5 Connection RS485, line B


A A
B B 6 Connection RS485, line B
BUS1 BUS2
7, 8 not assigned
(each looped through within BUS1 and BUS2)

12 3 4 5 6 7 8 12 3 4 5 6 7 8
200

190

LED
3

30
Ø4
.3

Supply connection

348
information
General
RS485 terminal box with lead connections
for centrifugal fans with EC motor size 084 (ebmBUS, RS485)

AC axial fans
– General remarks: RS485 terminal box with
• 2x RJ45 sockets for ebmBUS
• ebmBUS line with Molex Mini-Fit female connector for connection to the motor
• 3-pole 4-pin unit connector with AMP Mate-N-Lock female connector to
connect to motor

AC axial
S series
• Mode of operation display (LED2 green) and alarm display (LED 1 red)
– Delivery scope:
• Terminal Box
• Supply line (800 mm)
• ebmBUS line (800 mm)
– Material: ABS (fire rating V0 according to UL)

AC axial
K series
AC axial
A series
Part no.

EC axial fans
54002-4-1040
subject to alterations

– Pin configuration of supply lead:

EC axial
S series
Colour Assignment / function

green/yellow PE
black 2 N
57
black 1 L
61.6 73
45.4 – Pin configuration of ebmBUS lead:

Q-motor
61

Colour Assignment / function

yellow RS A
white RS B
111
87

99

red Operation: +15 V Alarm: 0V


blue Operation: 0 V Alarm: +15 V

ESM
– Pin configuration of RJ45 sockets:
Pin No. Assignment / function
Mounting dimensions
EC-SYSTEMS
5 RS B
58 6 RS A
Accessories
88

99
4

Technology

61
Contacts

349
Hand-held control terminal

– General remarks: Terminal to control networked fans and to set their parameters;
RS485 (ebmBUS)
– Type of protection: IP 20 (acc. to DIN EN 60529)
– Protection class: III
– Display: Plain text LCD, 2x8 characters
– Accumulator and charging electronics: 2 x round cell R6 DIN 40863 NiMH 1,500 mAh,
operating time approx. 40 hrs, standby time approx. 100 days, charging time max. 4 hrs.
– Parts included in delivery: Hand-held control terminal, power supply and accumulator
unit, BUS cable, 2 x round cell R6 NiMH 1,500 mAh

Perm. storage temp.


Perm. amb. temp.
Nominal voltage

Supply voltage
range power

Frequency
supply

Mass
Nominal data
Type VAC Hz VDC °C °C kg

CBC 000-AB06 -01 1~ 100-240 50/60 12 0 to +45 -20 to +65 0.4


subject to alterations

68 44
95

350
351
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
Speed setting device
with housing

– Material: Housing made of plastic


– Type of protection: IP 54
– Design: The speed setting device can be operated with the entire range of ebm-papst
EC fans. It is supplied with current via the fan's DC output and supplies a 0-10 V signal
that allows infinitely variable open loop speed control. The control also permits fan speed
measurement using a multimeter equipped with a frequency meter (for which a tach output
is given from the fan).
– Cable inputs: 4 x M16 or M20
– Mounting holes: Suitable for 4 mm mounts
Max. current draw

Perm. amb. temp.


Supply voltage

Resistance

Mass

Nominal data
Type VDC mA k °C kg

CLC 000-AE04 -01 10 1.1 0-10 Lin 50 0.10


subject to alterations

65 – Speed measurement: Connect a frequency meter to the connection points


(labelled + and -) on the PCB board. The fan has an output of 1 pulse per
revolution, so that the measured frequency can be converted into rpm using
the following equation:
rpm = frequency (Hz) x 60
65

– Comment:
• A single controller can be used to control multiple fans with the same speed setting.
• The connection to the controller is made using four screw connections or one Molex
connection (adaptor lead available).
• If the tach cable is required, this device can only be connected to one fan. Note that in
26

rare operating cases, it is possible that permanent connection of the tach cable can
cause a slight decrease in the maximum speed.
58

50
25
50

+ meter connection
– meter connection

352
– Electr.
connection:

red
Fan 2 yellow
blue
white

red
yellow
Fan 1

blue
white
yellow
red

white
blue
GND
Tacho
+10 V
Control

Tacho
GND
Control
+10 V

353
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
Speed setting device
without housing

– Design: The speed setting device can be operated with the entire range of ebm-papst
EC fans. It is supplied with current via the fan's DC output and supplies a 0-10 V signal
that allows infinitely variable open loop speed control. The control also permits fan speed
measurement using a multimeter equipped with a frequency meter (for which a tach output
is given from the fan).
– Mounting hole: 10 mm

Max. current draw

Perm. amb. temp.


Supply voltage

Resistance

Mass

Nominal data
Type VDC mA k °C kg

CLC 000-AD04 -01 10 1.1 0-10 Lin 50 0.05


subject to alterations

36 – Speed measurement: Connect a frequency meter to the connection points


28 (labelled + and -) on the PCB board. The fan has an output of 1 pulse per
4 x Ø3,5
revolution, so that the measured frequency can be converted into rpm using
the following equation:
rpm = frequency (Hz) x 60
36
28

– Comment:
• A single controller can be used to control multiple fans with the same speed setting.
• The connection to the controller is made using four screw connections or one Molex
connection (adaptor lead available).
• If the tach cable is required, this device can only be connected to one fan. Note that in
50

rare operating cases, it is possible that permanent connection of the tach cable can
22

12

cause a slight decrease in the maximum speed.

+ meter connection
– meter connection

354
– Electr.
connection:

red
Fan 2 yellow
blue
white

red
yellow
Fan 1

blue
white
yellow
red

white
blue
GND
Tacho
+10 V
Control

Tacho
GND
Control
+10 V

355
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
LISA
Control software for EC-SYSTEMS

– Version: LISA 5.1


– Features:
• Individual control and monitoring of 7,905 fans
• Group-oriented arrangement of the fans
• Level 1: Overview display for 10 floors
• Level 2: Overview display for 255 groups within a floor
• Level 3: Overview display for 31 fans within a group
• Broadcast command for one group or all fans
• Speed, temperature or pressure control
• Error message

Part no.

25711-2-0199
subject to alterations

– Suitable for: EC motors and electronics with ebmBUS


– System requirements: Windows 2000 / XP

356
information
General
Fan Control
Control software & accessories for Pocket PCs / PDAs

AC axial fans
– Version: Fan Control 1.00
– Features:
• Managing up to 31 fans
• Setting pre-set values and indicating actual values
• Setting parameters for PID control

AC axial
S series
• Setting fan address
• Setting mode of operation (heating/cooling)
• Alarm diagnosis
• Language selection for user interface

AC axial
K series
AC axial
A series
Part no.

EC axial fans
21500-1-0174
subject to alterations

– Delivery scope: Installation-CD, interface converter (RS232-RS485), BUS cable,


installation instruction and detailed manual (PDF). The Pocket PC / PDA and compatible

EC axial
S series
serial communication cables are not included in the scope of delivery.
– Suitable for: EC motors and electronics with ebmBUS
– System requirements: Pocket PC / PDA with Windows Mobile 5.0, RS232 interface,
and serial communication cable.
– Compatible Pocket PCs / PDAs: (as of 2006-09-14)
• Hewlett-Packard rx1950

Q-motor
• Hewlett-Packard hx2190
• Fujitsu-Siemens Pocket Loox C550
Set and actual values Mode of operation • Dell Axim x51v (624 MHz)
Refer to our website at www.ebmpapst.com/downloads for a continuously updated list of
approved Pocket PCs / PDAs along with the suitable serial communication cables.

ESM
EC-SYSTEMS

Fan address Graphic setting


Accessories
Technology
Contacts

357
HMS controller

– General remarks: The HMS controller is governed by a microprocessor and is specifically


designed for Heat Management Systems (= HMS). This controller allows for an almost
limitless programming variety as regards customer-specific fan speed / temperature
profiles. Moreover, this controller offers a multitude of the most diverse alarm
configurations.
Our HMS controller has been specially designed and adjusted to the product range of
ebm-papst in Mulfingen. Thus, any size of our fans or blowers can be used.
The most diverse of applications needing temperature-dependent control are possible.
Among these are applications in telecommunication and the IT industry, in refrigeration
and air-conditioning as well as in specific industrial plants and systems.

Perm. amb. temp.


Current draw (1)
Power input (1),

Power input (2),


Supply voltage

Mass
max.

max.

max.

Nominal data
Type VDC W W A °C kg

CCC 000-AA05 -03 16-57 10 130 0.175 -40 to +70 0.15


subject to alterations (1) without fans (2) per fan at nominal voltage

100 – Features:
7.25

81 • 4 fan speed / temperature characteristics that can be programmed independently


of each other
• 2 programmable no-frost relays for connecting 115 / 230 VAC heating devices
• 5 programmable alarm relays (with time lag):
- Temperature alarm (over / under-temperature)
- Fan good / bad alarm programming
- Temperature sensor alarm
75.5

- Programmable depending on signal inputs


• 4 programmable status outputs (with time lag):
- With "open collector" design to connect optical or acoustic displays / alarms
- Each fan speed can be set individually
• 4 signal inputs for external switches / limit switches
160

• Connection of two independent temperature sensors (NTCs) possible


• RS232 interface galvanic insulated
• Selective protection of each fan
• Programming via Windows software
(terminal program version 15 ff.: part no. 25710-2-0199)
70

– Requirements:
• Supply voltage of HMS controller: 16-57 VDC
• Fans with standard interface
- 24 / 48 VDC fan voltage
- PWM / linear control input (0-10 V)
- Open collector tach output
• NTC with R25 = 33 k (EPCOS type M 891/33k/J)
• System requirements: Windows 2000 / XP
– Safety: According to EN 50178
– EMC / EMI: Interference immunity EN 61000, interference emission EN 50081-1

358
information
General
AC axial fans
L1
16 - 57 VDC - +
K1
Heater 1 F1 3,15 A * / 250 V
H1
Fan 1
H2 + PWM Hall
-

AC axial
* / 250 V

S series
F6 10 A
F2 3,15 A * / 250 V
K2 Fan 2
N Heater 2
+ PWM Hall
-
N
F3 3,15 A * / 250 V
F7 10 A * / 250 V
Fan 3
N
+ PWM Hall
-

AC axial
K series
Alarm 1 Alarm 3 Alarm 5
F4 3,15 A * / 250 V
Alarm 2 Alarm 4 Fan 4
K3 K4 K5 K6 K7 + PWM Hall
-
Alarm
Status contact NTC 1 NTC 2 F5 3,15 A * / 250 V
1 2 3 4 1 2 3 4 1 1
DTR GND RS-232
RD TD RTS

AC axial
A series
1 1 1 electrically insulated

* time lag fuse


ê ê designation 9-pole Sub-D
2 4 3 5 7

0-57 V / 10 mA

EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

359
360
information
General
Accessories

AC axial fans
Guard grilles, streamers 362

Wall rings 372

AC axial
S series
Connection lines 374

Accessories for Q-motors and energy-saving motors (ESM) 374

Terminal boxes, capacitors, speed setting devices, motor protection switches, star-delta switches, repair switches 381

AC axial
K series
AC axial
A series
EC axial fans
EC axial
S series
Q-motor
ESM
EC-SYSTEMS
Accessories
Technology
Contacts

361
Guard grille

b – Material: Steel, phosphated and coated


in black plastic

c
Øe

Ød
Øf

a
h

Basket guard grille for S series axial fans


Part no. Size AC motor EC motor a b c d e f g h

19110-2-4039 200 068 074 (1) 3.9 6.5 4.3 260.0 25.0 229.0 — 39.0
19111-2-4039 250 068 074 (1) 3.9 6.5 4.5 300.0 25.0 271.0 — 38.0
19112-2-4039 250 068 074 (1) 3.9 6.5 4.5 300.0 25.0 271.0 — 53.0
74251-2-4039 250 — 074 (2) 5.0 6.2 4.2 300.0 125.0 265.0 — 38.0
64555-2-4039 300 068 074 (1) 4.5 4.3 4.3 360.0 58.0 329.5 — 50.0
64556-2-4039 300 068 — 4.5 4.3 4.3 360.0 58.0 329.5 26.0 50.0
64557-2-4039 300 074 — 5.0 6.5 6.5 360.0 90.0 324.0 — 50.0
74301-2-4039 300 — 074 (2) 5.0 4.2 4.2 360.0 125.0 331.0 10.0 60.0
64558-2-4039 315 068 — 4.5 6.5 4.5 375.0 58.0 336.5 30.0 80.0
74316-2-4039 315 — 074 (2) 5.0 6.4 4.2 375.0 125.0 344.0 35.0 85.0
64559-2-4039 330 068 — 4.5 6.5 4.5 410.0 58.0 354.5 30.0 80.0
74331-2-4039 330 — 074 (2) 5.0 6.4 4.2 410.0 125.0 370.0 35.0 85.0
64562-2-4039 350 068 — 5.0 6.5 4.5 422.0 58.0 374.0 30.0 80.0
74351-2-4039 350 — 074 (2) 5.0 6.4 4.2 422.0 125.0 378.0 35.0 85.0
64379-2-4039 400 074 — 5.0 9.0 6.5 470.0 90.0 414.0 30.0 80.0
74370-2-4039 400 — 084 (2) 5.0 9.0 6.5 470.0 164.0 420.0 30.0 80.0
64536-2-4039 420 074 — 5.0 9.0 6.5 502.0 90.0 452.0 30.0 80.0
64570-2-4039 420 094 — 5.0 9.0 6.5 502.0 115.0 452.0 30.0 60.0
64378-2-4039 450 074 — 5.0 9.0 6.5 522.0 90.0 476.0 30.0 80.0
74372-2-4039 450 — 084 (2) 5.0 9.0 6.5 522.0 164.0 482.0 30.0 80.0
25943-2-4039 450 094 (3) — 6.0 9.0 6.5 522.0 115.0 472.0 17.5 67.5
25938-2-4039 450 094 (4) — 7.0 9.0 7.0 515.0 115.0 472.0 16.5 80.0
subject to alterations (1) DC-fed (2) Mains-powered (3) Blades made of plastic (4) Blades made of sheet steel

362
information
General
Guard grille

AC axial fans
h b – Material: Steel, phosphated and coated
in black plastic

AC axial
S series
c
Ød
Øe
Øf

AC axial
K series
a

Guard grille for S-series axial fans

AC axial
A series
Part no. Size AC motor EC motor a b c d e f g h

18656-2-4039 200 068 — 3.9 4.6 4.6 245.0 58.0 — — —


62622-2-4039 200 — 074 (1) 3.9 4.6 4.6 245.0 58.0 — — —
09414-2-4039 250 068 — 3.9 4.6 4.6 290.0 58.0 — — —

EC axial fans
62623-2-4039 250 — 074 (1) 3.9 4.6 4.6 290.0 58.0 — — —
74250-2-4039 250 — 074 (2) 5.0 4.2 4.2 290.0 125.0 — — —
09415-2-4039 300 068 — 3.9 4.6 4.6 360.0 58.0 — — —
62624-2-4039 300 — 074 (1) 3.9 4.6 4.6 360.0 58.0 — — —
72320-2-4039 300 068 — 4.5 4.3 4.3 360.0 58.0 329.0 26.0 26.0
64052-2-4039 300 074 — 5.0 6.5 6.5 360.0 90.0 — — —

EC axial
S series
74300-2-4039 300 — 074 (2) 5.0 4.2 4.2 360.0 125.0 — — —
64491-2-4039 315 068 — 4.5 6.4 4.3 375.0 58.0 336.0 33.0 30.0
74315-2-4039 315 — 074 (2) 5.0 6.4 4.2 375.0 125.0 344.0 35.0 35.0
64490-2-4039 330 068 — 4.5 6.4 4.3 410.0 58.0 371.0 30.0 30.0

Q-motor
74330-2-4039 330 — 074 (2) 5.0 6.4 4.2 410.0 125.0 370.0 35.0 35.0
64563-2-4039 350 068 — 5.0 6.5 4.5 422.0 58.0 374.0 30.0 30.0
74350-2-4039 350 — 074 (2) 5.0 6.4 4.2 422.0 125.0 378.0 35.0 35.0
64538-2-4039 400 / 420 074 — 5.0 9.0 6.5 502.0 90.0 452.0 30.0 30.0
74373-2-4039 400 — 084 (2) 5.0 9.0 6.5 502.0 164.0 458.0 30.0 38.0
64539-2-4039 450 074 — 5.0 9.0 6.5 522.0 90.0 476.0 30.0 30.0

ESM
74374-2-4039 450 — 084 (2) 5.0 9.0 6.5 522.0 164.0 482.0 30.0 38.0
25950-2-4039 450 094 — 7.0 9.0 7.0 560.0 115.0 517.0 16.5 38.0
subject to alterations (1) DC-powered (2) Mains-powered EC-SYSTEMS
Accessories
Technology
Contacts

363
Guard grille

h 6,4 – Material: Steel, phosphated and coated


in black plastic
– Wall rings: See p. 373
– Comment: Contact us for article numbers
for complete fans.
c
Ød
Øe

g
a

Typical installation

Guard grille for S series fans (for nozzle-side mounting to square wall ring with long nozzle)
Part no. Size AC motor EC motor a c d e g h

35803-2-4039 400 074 (4 poles) — 5.0 6.5 413.0 90.0 — 16.0


35804-2-4039 400 074 (6 poles) — 5.0 6.5 413.0 90.0 30.0 28.0
74377-2-4039 400 — 084 (2) 5.0 6.5 413.0 164.0 30.0 48.0
35805-2-4039 450 074 (4 poles) — 5.0 6.5 466.0 90.0 — 25.0
35806-2-4039 450 074 (6 poles) — 5.0 6.5 466.0 90.0 20.0 30.0
74376-2-4039 450 — 084 (2) 5.0 6.5 467.0 164.0 30.0 48.0
26510-2-4039 450 094 — 7.0 7.0 466.0 115.0 16.5 41.0
subject to alterations (2) mains-powered

h 9 – Material: Steel, phosphated and coated


in black plastic

c
Ød
Øe
Øf

Basket guard grille for S series fans (for mounting to square wall ring with long nozzle)
Part no. Size AC motor EC motor a c d e f g h

63978-2-4039 420 / 450 074 — 5.0 6.5 562.0 90.0 526.0 30.0 30.0
74375-2-4039 450 — 084 (2) 5.0 6.5 562.0 164.0 526.0 30.0 38.0
25950-2-4039 450 094 — 7.0 7.0 560.0 115.0 523.0 16.5 38.0
subject to alterations (2) mains-powered

364
information
General
Guard grille

AC axial fans
max. g d – Material: Steel, phosphated and coated
in black plastic
2,8
max. 8

AC axial
S series
e
Ø87
Ø58

Øb
Øc

AC axial
K series
a
f

Basket guard grille for A series axial fans

AC axial
A series
Part no. Size a b c d e f g

19110-2-4039 200 3.9 260.0 229.0 6.5 4.3 39.0 6.0


19111-2-4039 250 3.9 300.0 271.0 6.5 4.5 38.0 6.0
19112-2-4039 250 3.9 300.0 271.0 6.5 4.5 53.0 6.0

EC axial fans
19113-2-4039 300 3.9 360.0 327.0 6.5 4.5 35.0 6.0
19114-2-4039 350 4.5 422.0 375.0 6.5 4.5 72.0 6.0
19115-2-4039 350 4.5 422.0 380.0 6.5 4.5 54.0 6.0
63406-2-4039 400 4.5 470.0 428.0 9.0 4.5 67.0 8.0
subject to alterations

EC axial
S series
h b – Material: Steel, phosphated and coated
in black plastic

Q-motor
g

c
d
e
f

ESM
a
EC-SYSTEMS

Guard grille for A series axial fans


Part no. Size a b c d e f g h

18656-2-4039 200 3.9 4.6 4.6 245.0 58.0 195.0 — —


09414-2-4039 250 3.9 4.6 4.6 290.0 58.0 247.0 — —
Accessories

09415-2-4039 300 3.9 4.6 4.6 360.0 58.0 300.0 — —


19699-2-4039 315 4.5 6.3 4.3 375.0 58.0 327.0 — 3.5
69667-2-4039 350 4.5 6.5 4.5 422.0 58.0 387.0 — 6.5
19117-2-4039 400 4.5 6.3 4.3 500.0 58.0 467.5 7.0 14.0
subject to alterations
Technology
Contacts

365
Guard grille

b – Material: Steel, phosphated and coated


in black plastic

c
Øe

Ød
Øf

a
h

Basket guard grille for K series axial fans


Part no. Size a b c d e f g h

66024-2-4039 250 4.5 4.3 4.3 300.0 58.0 271.0 26.0 60.0
77709-2-4039 300 3.9 4.5 4.5 360.0 58.0 340.0 26.0 26.0
19115-2-4039 350 4.5 6.5 4.5 422.0 58.0 380.0 — 54.0
62229-2-4039 360 4.5 6.3 4.3 400.0 58.0 357.0 12.0 16.0
64378-2-4039 450 5.0 9.0 6.5 522.0 90.0 476.0 30.0 80.0
64539-2-4039 450 5.0 9.0 6.5 522.0 90.0 476.0 30.0 30.0
subject to alterations

74 – Material: Steel, galvanized and blue


chromated (alternative: nickel-plated)
Ø182

Ø191

1,5 5,8
4 208

Guard grille for diagonal fan


Part no. Size

26388-2-4039 180
subject to alterations

366
information
General
Guard grille

AC axial fans
2,4 – Material: Steel, plastic-coated
(silver-metallic gloss)

5,5 +0.3

AC axial
S series
Ø 217,6 ±1
Ø 240 +2

Ø219,4

AC axial
K series
22,3

Guard grille for diagonal fan (inlet side mounting)

AC axial
A series
Part no. Size

35139-2-4039 208
subject to alterations

EC axial fans
EC axial
S series
2,4 – Material: Steel, plastic-coated
(silver-metallic gloss)
5,5 +0.3

Q-motor
Ø 240 +2

Ø 231 -1

Ø225

ESM
8,8

EC-SYSTEMS
Guard grille for diagonal fan (outlet side mounting)
Part no. Size

35138-2-4039 208
subject to alterations
Accessories
Technology
Contacts

367
Guard grille

A-B – Material: Steel, galvanized and blue


5 +1 passivated
167,5 ±0,5

3 ±0,25

11,5
65
5,5 ±0,2
152 ±1

A
137

56
6

2,5
B

Guard grille for diagonal fan


Part no. Size

51019-2-4039 130
subject to alterations

– Material: Steel, galvanized and blue


chromated (alternative: nickel-plated)

159
162
4,3

Ø142

1,5
2
6

Guard grille for axial fan (according to EN 294)


Part no. Size

50952-2-4039 130 / 142 / 143


subject to alterations

368
information
General
Guard grille

AC axial fans
2 – Material: Steel, plastic-coated
(silver-metallic gloss)

AC axial
S series
Ø154±1
Ø162

Ø139

AC axial
K series
4.3±0.3 4

Guard grille for diagonal fan

AC axial
A series
Part no. Size

03749-2-4039 142
04013-2-4039 143
subject to alterations

EC axial fans
– Material: Steel, plastic-coated
(silver-metallic gloss)

EC axial
S series
a
Ød

Øc

Q-motor
2,4 b
6,4

Guard grille for diagonal fan

ESM
Part no. Size a b c d

78128-2-4039 200 240.0 5.4 221.5 208.0


09418-2-4039 250 295.0 6.4 278.5 270.0
EC-SYSTEMS

subject to alterations
Accessories
Technology
Contacts

369
Guard grille

0˚ – Material: Steel, phosphated and coated


6x6 in black plastic

a
max. 8

b
c

Guard grilles (e.g. for axial fans)


Part no. Size a b c

09513-2-4039 200 250.0 227.0 6.0


09518-2-4039 250 295.0 265.0 7.0
09532-2-4039 300 380.0 323.0 9.0
subject to alterations

370
information
General
Streamers

AC axial fans
– Material: Plastic PA6, 30GV, black
(in accordance with UL 94 HB)

AC axial
S series
103
Øb

Øc
a

AC axial
K series
10 103
53
Typical installation

Streamers for axial fans

AC axial
A series
Part no. Size a b c Standard types (1)

S4D 315-AP10 -30


29550-2-2955 315 10.0 321.0 333.0 S4E 315-AP18 -30
S6E 315-AP02 -30

EC axial fans
S4D 350-BR06 -30 S4E 350-AR06 -30
29551-2-2955 350 10.0 361.0 373.0 S4D 350-AR06 -30 S6E 350-BR08 -30
S4E 350-BR06 -30 S6E 350-AR08 -30
S4D 400-AP12 -03
29552-2-2955 400 10.0 401.0 413.0 S4E 400-AP02 -03
S6E 400-AP10 -30

EC axial
S series
S4E 450-GA09 -01
29553-2-2955 450 12.0 466.0 478.0

S4E 500-CY09 -01 S6E 500-AS05 -01

Q-motor
29554-2-2955 500 13.0 496.0 508.0 S4E 500-AY09 -01 S6E 500-CT05 -01
S6E 500-CS05 -01 S6E 500-AT05 -01
subject to alterations (1) Mounting options for other axial fans respectively basket guard grilles upon request.

Thrust ranges (measured in a typical heat exchanger) Comparison

ESM
[m/s]

1,6

1,4
EC-SYSTEMS

1,2

1,0
With streamer
0,8

0,6
Accessories

0,4

0,2
v

s 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 [m] Without streamer


Technology

S4E315 (1670 m3/h @ 35 Pa) S4E350 (2140 m3/h @ 60 Pa) S4E450 (5430 m3/h @ 65 Pa)
S4E400 (3230 m3/h @ 45 Pa) S4E500 (5060 m3/h @ 180 Pa)
Contacts

371
Wall rings

b – Material: Sheet steel, pre-galvanised and


f d coated in black plastic
˚
60
6x

i
Øh
15˚

Øc

Øg
Øa

Wall rings with long nozzle for axial fans


Part no. Size a b c d e f g h i

18912-2-4037 200 280.0 80.0 202.5 5.0 7.0 4.5 245.0 250.0 1.25
64009-2-4037 250 (S series) 320.0 86.5 259.5 6.0 7.0 4.5 290.0 295.0 1.25
18910-2-4037 250 (A series) 320.0 85.0 256.5 6.0 7.0 4.5 290.0 295.0 1.25
18908-2-4037 300 397.0 80.0 326.0 11.0 9.0 M4 360.0 380.0 1.50
18902-2-4037 315 397.0 74.0 347.0 11.0 9.0 M6 374.0 380.0 1.50
18892-2-4037 330 440.0 80.0 369.0 11.0 9.0 M6 408.0 404.0 1.50
18900-2-4037 350 460.0 80.0 390.0 12.0 9.0 M6 422.0 442.0 1.50
18930-2-4037 400 528.0 96.0 419.0 12.0 9.0 M8 500.0 504.0 1.50
18929-2-4037 420 544.0 96.0 447.0 12.0 9.0 M8 500.0 520.0 1.50
64000-2-4037 450 (1) 607.0 100.0 465.0 14.0 11.0 M8 560.0 578.0 1.50
subject to alterations (1) For mounting the axial fan, use guard grille 63978-2-4039

1,5 – Material: Sheet steel, pre-galvanised


5
R1

Øb
±0
,5
Ø a ±1

c
d

45

Square wall rings with short nozzle for S series axial fans
Part no. Size a b c d

35222-2-4037 350 358.0 422.0 795.0 M6


35223-2-4037 400 400.0 468.0 840.0 M8
35224-2-4037 420 426.0 500.0 850.0 M8
35225-2-4037 450 452.0 515.0 850.0 M8
subject to alterations

372
information
General
Wall rings

AC axial fans
b – Material: Sheet steel, pre-galvanised and
d
coated in black plastic
1,5

AC axial
S series
Øc

AC axial
K series
e

h
a

Square wall rings with long nozzle for axial fans

AC axial
A series
Part no. Size a b c d e f g h

18918-2-4037 200 312.0 52.0 203.0 6.0 7.0 4.5 245.0 260.0
37701-2-4037 250 (S series) 370.0 56.0 260.0 6.0 7.0 4.5 290.0 320.0
18933-2-4037 250 (A series) 370.0 55.0 257.0 6.0 7.0 4.5 290.0 320.0

EC axial fans
18924-2-4037 300 430.0 80.0 326.0 11.0 9.0 4.5 360.0 380.0
18903-2-4037 315 430.0 72.5 345.0 11.0 9.0 M6 375.0 380.0
18901-2-4037 350 485.0 80.0 388.0 12.0 9.0 M6 422.0 435.0
64005-2-4037 400 540.0 98.0 417.0 12.0 9.0 M8 500.0 490.0
64006-2-4037 420 (1) 576.0 94.0 439.0 14.0 11.0 M8 560.0 535.0
64007-2-4037 450 (1) 576.0 100.0 465.0 14.0 11.0 M8 560.0 535.0

EC axial
S series
subject to alterations (1) For mounting the axial fan, use guard grille 63978-2-4039

Q-motor
b – Material: Sheet steel, pre-galvanised and
d coated in black plastic
– Guard grilles: See p. 364
– Comment: Contact us for article numbers
4x90˚
for complete fans.
45˚

ESM
Øc

f 4xM6
Øe

EC-SYSTEMS

h
a Typical installation

Square wall rings with long nozzle for S series axial fans (for nozzle-side mounting)
Accessories

Part no. Size a b c d e f h

64020-2-4037 400 540.0 98.0 409.0 12.0 9.0 10.0 490.0


64001-2-4037 450 576.0 100.0 463.0 14.0 11.0 10.0 535.0
subject to alterations
Technology
Contacts

373
Connection leads

– Plug terminal: 2.8 x 0.5 mm


7,5

15
10
7,5 a 23

Connection lines for axial compact fan (with plug terminal)


Part no. Size a

01434-4-6711 142 / 143 610


01477-4-6711 142 / 143 1000
01505-4-6711 142 / 143 2000
subject to alterations

a – Design: Cable conforms to UL standards,


31,5 40 sealed plug
10

7
27,5
22,5

9,3

Jacketed cable, internal line Brass lead tips


(UL Style 2464/1061)
3 x AWG20 (approx. 0.5 mm2)

Connection lines for energy-saving motors (ESM)


Part no. a

10637-4-1040 450
10640-4-1040 600
10638-4-1040 1500
10639-4-1040 32000
subject to alterations

374
information
General
Programming device
for energy-saving motors (ESM)

AC axial fans
– Description: Programming unit for setting 2 possible speeds via the USB port of a PC.
– System requirements: Windows 2000 / XP
– Delivery scope: Programming unit
Supply plug unit
USB connection line

AC axial
S series
Motor connecting cable
Programming software
– Type of protection: IP 20
– Protection class: III

AC axial
K series
Perm. storage temp.
Perm. amb. temp.

AC axial
A series
Nominal data
Type °C °C

EC axial fans
CBC 000-AC02 -02 0 to +45 -20 to +65
subject to alterations

50

EC axial
S series
24

Q-motor
ESM
90

EC-SYSTEMS
Accessories
Technology
Contacts

375
Connection leads

12,9
Brass lead tips

24
8

41 85 Cable cross-section (3 x 0.75 mm2)

Connection lines for Q-motors (plug terminal design)


Part no. a

79572-4-6711 420
79573-4-6711 970
79574-4-6711 1470
79575-4-6711 1970
79576-4-6711 2470
79577-4-6711 2970
79578-4-6711 3470
79579-4-6711 3970
79580-4-6711 4470
62402-4-6711 4970
subject to alterations

376
information
General
Axial impellers

AC axial fans
b b – Material: Sheet aluminium
a
c c

 Direction of rotation

AC axial
S series
6,6

AC axial
K series
 "V" "A"  4 x Ø 4.0 with pitch circle for holes Ø 25.4 mm

Axial impeller for Q-motors and energy-saving motors (ESM)

AC axial
A series
Part no. for direction of air flow "V" Part no. for direction of air flow "A" Blade angle  a b c

73801-2-3634 73761-2-3634 22° ± 1°30’ 154.0 27.5 14.0


73802-2-3634 73762-2-3634 28° ± 1°30’ 154.0 32.0 16.0
73803-2-3634 73763-2-3634 34° ± 1°30’ 154.0 37.0 18.0

EC axial fans
73804-2-3634 73764-2-3634 22° ± 1°30’ 172.0 31.0 14.5
73805-2-3634 73765-2-3634 28° ± 1°30’ 172.0 36.0 17.0
73806-2-3634 73766-2-3634 34° ± 1°30’ 172.0 42.0 21.0
73807-2-3634 73767-2-3634 22° ± 1°30’ 200.0 32.0 15.5
73808-2-3634 73768-2-3634 28° ± 1°30’ 200.0 37.5 18.0
73809-2-3634 73769-2-3634 34° ± 1°30’ 200.0 45.0 22.0

EC axial
S series
73810-2-3634 73770-2-3634 22° ± 1°30’ 230.0 35.0 17.5
73811-2-3634 73771-2-3634 28° ± 1°30’ 230.0 43.0 21.5
73812-2-3634 73772-2-3634 34° ± 1°30’ 230.0 50.0 24.0
73813-2-3634 73773-2-3634 22° ± 1°30’ 254.0 37.0 19.0

Q-motor
73814-2-3634 73774-2-3634 28° ± 1°30’ 254.0 45.0 23.5
73815-2-3634 73775-2-3634 34° ± 1°30’ 254.0 52.0 26.0
73816-2-3634 73776-2-3634 22° ± 1°30’ 300.0 43.0 21.5
73817-2-3634 73777-2-3634 28° ± 1°30’ 300.0 53.5 26.5
73818-2-3634 73778-2-3634 34° ± 1°30’ 300.0 61.0 30.0
subject to alterations

ESM
EC-SYSTEMS
Accessories
Technology
Contacts

377
Guard grille

– Material: Steel, galvanized and blue


chromated

94,5
Øa

2,7 5
c

Guard grille for Q-motors and energy-saving motors (ESM)


Part no. Size Max. blade angle  at "V" Max. blade angle  at "A" a b c

50967-2-4039 154 34° 34° 170.0 190.0 11.5


50968-2-4039 172 34° 34° 188.0 208.0 11.5
50969-2-4039 200 34° 28° 214.0 236.0 11.5
50970-2-4039 230 28° 28° 246.0 266.0 17.5
50971-2-4039 254 28° 28° 270.0 290.0 17.5
50972-2-4039 (1) 300 — 22° 324.0 344.0 17.5
subject to alterations (1) When used with M4Q045-EF, blade angles up to 34° are possible

2,7 – Material: Steel, galvanized and blue


chromated

94,5
92
Øa
Øb

c 5

Basket guard grille for Q-motors and energy-saving motors (ESM)


Part no. Size Max. blade angle  at "V" Max. blade angle  at "A" a b c

66309-2-4039 172 34° 34° 188.0 208.0 37.5


66310-2-4039 200 34° 28° 212.0 236.0 37.5
66311-2-4039 230 28° 28° 246.0 266.0 40.0
66312-2-4039 254 28° 28° 270.0 290.0 40.0
66313-2-4039 (1) 300 — 22° 324.0 344.0 46.8
subject to alterations (1) When used with M4Q045-EF, blade angles up to 34° are possible

378
information
General
Wall rings

AC axial fans
– Material: Sheet steel, coated in grey plastic
67

67

Øa
d  "V"
4,3

AC axial
S series
b

,5
R3
4,3 2 1
c 48

AC axial
K series
Wall rings for Q-motors and energy-saving motors (ESM), direction of air flow "V"

AC axial
A series
Part no. Size Max. blade angle  a b c d

52542-2-4037 154 34° 164.0 190.0 200.0 24.0


52543-2-4037 172 34° 182.0 208.0 223.0 24.0
52544-2-4037 200 34° 210.0 236.0 246.0 24.0

EC axial fans
52545-2-4037 230 28° 240.0 266.0 276.0 24.0
52546-2-4037 254 28° 264.0 290.0 300.0 24.0
52547-2-4037 (1) 300 22° 308.0 344.0 356.0 24.0
subject to alterations (1) When used with M4Q045-EF, blade angles up to 34° are possible

EC axial
S series
36 – Material: Sheet steel, coated in grey plastic
,5
1 R4
67

67

d "A" 

Q-motor
4,3 2
Øa
b

4,3
c

ESM
EC-SYSTEMS
Wall rings for Q-motors and energy-saving motors (ESM), direction of air flow "A"
Part no. Size Max. blade angle  a b c d

52550-2-4037 154 34° 162.0 190.0 200.0 24.0


52551-2-4037 172 34° 180.0 208.0 223.0 24.0
52552-2-4037 200 28° 208.0 236.0 246.0 24.0
Accessories

52553-2-4037 230 28° 238.0 266.0 276.0 24.0


52554-2-4037 254 28° 262.0 290.0 300.0 24.0
52555-2-4037 (1) 300 22° 308.0 344.0 356.0 24.0
subject to alterations (1) When used with M4Q045-EF, blade angles up to 34° are possible
Technology
Contacts

379
Mounting bracket

Vers. 1 Vers. 2 Vers. 3 – Material: Sheet steel, galvanized and blue


b b
chromated

10
a 9°

a
2,5

2,5
c c 26
d d
18
18 18 4,2
8,2
8,2

24
6,2
25
25

16

40
4,3 4,3

18
14 14 5
8

16,2

Mounting bracket for Q-motors (foot measure 18 mm)


Part no. Size Vers. a b c d Suitable Q-motor

51025-2-4053 172 1 56.0 51.0 78.0 100.0 M4Q045-BD01-**


51028-2-4053 200 1 67.0 51.0 78.0 100.0 M4Q045-BD01-**, M4Q045-CA01-**
51026-2-4053 230 1 74.5 51.0 78.0 100.0 M4Q045-CA01-**, M4Q045-CA03-**
51027-2-4053 254 2 85.5 51.0 78.0 100.0 M4Q045-CA03-**, M4Q045-CF01-**, M4Q045-DA01-**
51014-2-4053 300 3 112.0 — 150.0 172.0 M4Q045-DA01-**, M4Q045-DA05-**, M4Q045-EA01-**, M4Q045-EF01-**
subject to alterations

Vers. 1 Vers. 2 Vers. 3 – Material: Sheet steel, galvanized and blue


51 51 51
chromated
a

a
2,5

2,5

2,5

78 78 78
100 100 100
26
26
7

26
8,2
8,2
8,2

31,8
50,3
21
24

40
8

13
1,5

14 4,3
14 4,3 14 4,3

Mounting bracket for Q-motors (foot measure 26 mm)


Part no. Size Vers. a Suitable Q-motor

71881-2-4053 154 1 39.0 M4Q045-BD01-**


71882-2-4053 172 1 52.0 M4Q045-BD01-**
200 1 72.0 M4Q045-BD01-**, M4Q045-CA01-**
71883-2-4053
230 1 72.0 M4Q045-CA01-**, M4Q045-CA03-**
71884-2-4053 254 1 84.0 M4Q045-CA03-**, M4Q045-CF01-**
71885-2-4053 254 2 84.0 M4Q045-DA01-**
71886-2-4053 300 2 109.0 M4Q045-DA01-**, M4Q045-DA05-**
71887-2-4053 300 3 109.0 M4Q045-EA01-**, M4Q045-EF01-**
subject to alterations

380
information
General
Mounting angles, terminal boxes

AC axial fans
22x45˚ 15,5 2
– Material: Sheet steel, hot-galvanised

15,5
75
67

AC axial
S series
4,3
a

67

98 25
8,2

10

AC axial
K series
78
5x45˚

Mounting angle for energy-saving motors (ESM)

AC axial
A series
Part no. Size Max. blade angle  at "V" Max. blade angle  at "A" a b

63500-2-4060 154 / 172 34° 34° 103.0 152.0


63501-2-4060 200 34° 28° 123.0 172.0
63502-2-4060 230 / 254 28° 28° 135.0 184.0

EC axial fans
subject to alterations

EC axial
S series
= = – Material: ABS
91,5 b 56 3 – Description: Two-piece terminal box for
AC motors of size 068 or 074, terminal strip
c

with 4- or 7-pole.
Øa

12

Suitable for installation of capacitor with


10 µF max.
58
94

Q-motor
29

– Type of protection: IP 54

18 27,5

ESM
Terminal box
EC-SYSTEMS

Part no. AC motor a b c

64442-1-7612 068 (4 poles) 22.0 5.0 4.3


64444-1-7612 068 (7 poles) 22.0 5.0 4.3
64443-1-7612 074 (4 poles) 12x14.5 10.5 5.5
64445-1-7612 074 (7 poles) 12x14.5 10.5 5.5
Accessories

subject to alterations
Technology
Contacts

381
Capacitors

– Material: Housing made of thermoplastic resin


10 b c ±10 – Connection line: Multi-lead
7 ±1 PVC cable 0.5 mm2 with brass lead tips
– Approval: VDE according to DIN EN 60252
(VDE 0560/8)
Øa
M8

– Calculated life time:


400 V; -25 to +85°C; 30,000 hrs; class A
450 V; -25 to +85°C; 10,000 hrs; class B

MKP motor capacitors (without fuse)


Part no. Capacity a b (max.) c

02100-4-7320 1.0 µF 25-28 58.0 235.0


99282-4-7320 1.5 µF 25-28 58.0 235.0
99283-4-7320 2.0 µF 25-28 58.0 235.0
02103-4-7320 2.5 µF 25-28 70.0 235.0
68462-4-7320 3.0 µF 25-28 70.0 235.0
99284-4-7320 4.0 µF 28-32 58.0 235.0
02101-4-7320 5.0 µF 30-36 70.0 235.0
99285-4-7320 6.0 µF 30-36 70.0 235.0
66788-4-7320 7.0 µF 30-36 72.0 100.0
99286-4-7320 8.0 µF 35-40 72.0 235.0
99287-4-7320 10.0 µF 35-40 72.0 200.0
66786-4-7320 12.0 µF 40.0 72.0 100.0
30457-4-7320 14.0 µF 40-45 92.0 150.0
50090-4-7320 16.0 µF 35-40 95.0 100.0
90034-4-7320 20.0 µF 40.0 95.0 235.0
90025-4-7320 25.0 µF 40.0 120.0 235.0
subject to alterations

382
information
General
Capacitors

AC axial fans
c – Material: Plastic cap, aluminium cup
10 b – Designation: FPU or P2 according to
IEC 252 (non-flammable, non-explosive,
circuit-breaking)

Ø a + 3,5
– Approval: VDE according to DIN EN 60252
Øa
M8

AC axial
S series
(VDE 0560/8)
– Calculated life time:
420 V; -25 to +85°C; 30,000 hrs; class A
470 V; -25 to +85°C; 10,000 hrs; class B
7 ±1 35 +5 500 V; -25 to +85°C; 3,000 hrs; class C
235 +10

AC axial
K series
-5

MKP motor capacitors FPU or P2 (with fuse)

AC axial
A series
Part no. Capacity a b (max.) c (max.)

02151-4-7320 1.0 µF 25-30 77.0 92.0


02155-4-7320 1.5 µF 25.0 77.0 92.0
02156-4-7320 2.0 µF 25.0 77.0 92.0

EC axial fans
02159-4-7320 2.5 µF 30.0 71.0 92.0
02160-4-7320 3.0 µF 30.0 71.0 92.0
02161-4-7320 4.0 µF 25-30 104.0 135.0
02162-4-7320 5.0 µF 25-30 104.0 113.0
02163-4-7320 6.0 µF 30.0 101.0 110.0
02164-4-7320 7.0 µF 30-35 101.0 110.0

EC axial
S series
02165-4-7320 8.0 µF 30-35 102.0 111.0
02166-4-7320 10.0 µF 35.0 96.0 110.0
02167-4-7320 12.0 µF 35.0 96.0 110.0
90026-4-7320 14.0 µF 40.0 130.0 139.0

Q-motor
02168-4-7320 16.0 µF 40.0 96.0 130.0
02169-4-7320 20.0 µF 40.0 116.0 130.0
02170-4-7320 25.0 µF 40-45 116.0 130.0
subject to alterations

– Pull-off protector: The housing expands

ESM
by max. 9 mm. The protector responds to
overload by the generated excess pressure
max. 9 mm

snapping off the internal lead in a predeter-


mined breaking point.
EC-SYSTEMS
– Mounting: c is the overall dimension of the
capacitor which has to be taken into account
when mounting the part. The capacitor
design, however, depends on the manufac-
turer. The expansion (9 mm) is either added
to dimension b, or it is already integrated in
Accessories

the capacitor.
Technology
Contacts

383
Speed setting device, 3-phase (with 5 steps)
for wall assembly

– Technical features: Input for TOP


– Voltage steps: 3~ 400 / 280 / 230 / 180 / 140 VAC
– Type of protection: IP 20 (with vertical installation)

Nominal voltage

Current draw
Frequency

Mass

Nominal data
Type VAC Hz A kg

TCD 020-AA01 -05 3~ 400 50/60 2.0 9.5


TCD 040-AA01 -05 3~ 400 50/60 4.0 13.9
TCD 070-AA01 -05 3~ 400 50/60 7.0 19.7
subject to alterations

266
185

4xØ5,5
189
166

309
224

189

304

384
information
General
Speed setting device, single-phase (with 5 steps)
for wall assembly

AC axial fans
– Technical features: Input for TOP
– Voltage steps: 1~ 230 / 160 / 145 / 130 / 105 VAC
– Type of protection: IP 40

AC axial
S series
AC axial
K series
Nominal voltage

AC axial
A series
Current draw
Frequency

Mass

Nominal data
Type VAC Hz A kg

EC axial fans
TCE 021-AA01 -05 1~ 230 50/60 2.1 3.6
TCE 040-AA01 -05 1~ 230 50/60 4.0 4.8
TCE 075-AA01 -05 1~ 230 50/60 7.5 6.5
subject to alterations

EC axial
S series
144
4xØ7
86

Q-motor
ESM
167

147

EC-SYSTEMS

204
Accessories
154

200
Technology
Contacts

385
Motor protection switch, 3-phase
for assembly inside a cabinet

– Technical features: Input for TOP

Nominal voltage

Current draw
Frequency

Mass

Nominal data
Type VAC Hz A kg Auxiliary contactor

TPD 250-AB01 -01 3~ 400 50/60 25.0 0.3 Without auxiliary contactor
TPD 250-AB01 -02 3~ 400 50/60 25.0 0.3 With break contact
TPD 250-AB01 -03 3~ 400 50/60 25.0 0.3 With make contact
subject to alterations

– Electr. connection:
68

7 54,5
66,5

386
information
General
Motor protection switch, single-phase
for assembly inside a cabinet

AC axial fans
– Technical features: Input for TOP

AC axial
S series
AC axial
K series
Nominal voltage

AC axial
A series
Current draw
Frequency

Mass

Nominal data
Type VAC Hz A kg Auxiliary contactor

EC axial fans
TPE 100-AB01 -01 3~ 230 50/60 10.0 0.3 Without auxiliary contactor
TPE 100-AB01 -02 3~ 230 50/60 10.0 0.3 With break contact
TPE 100-AB01 -03 3~ 230 50/60 10.0 0.3 With make contact
subject to alterations

EC axial
S series
52,5 – Electr. connection:
46

Q-motor
103

45

70
78

ESM
EC-SYSTEMS
Accessories
Technology
Contacts

387
Motor-protection switch, single phase and three-phase
for wall assembly

– Technical features: Input for TOP


– Type of protection: IP 55

Nominal voltage

Current draw
Frequency

Mass

Nominal data
Type VAC Hz A kg Auxiliary contactor

TPD 250-AA01 -01 3~ 400 50/60 25.0 0.6 Without auxiliary contactor
TPD 250-AA01 -02 3~ 400 50/60 25.0 0.6 With break contact
TPD 250-AA01 -03 3~ 400 50/60 25.0 0.6 With make contact
TPE 100-AA01 -01 1~ 230 50/60 10.0 0.6 Without auxiliary contactor
TPE 100-AA01 -02 1~ 230 50/60 10.0 0.6 With break contact
TPE 100-AA01 -03 1~ 230 50/60 10.0 0.6 With make contact
subject to alterations

92 – Electr. connection, three-phase:


79 80
141

– Electr. connection, single-phase:

38 20

388
information
General
Star-delta switch / repair switch
Third-party accessories from Möller Electric GmbH

AC axial fans
For more information: www.moeller.net

AC axial
S series
AC axial
K series
for wall installation

Star-delta switch (available from Möller Electric GmbH)

AC axial
A series
Designation Installation

T0-4-8410/I1 Wall installation


T0-4-8410/E Cabinet installation
subject to alterations

EC axial fans
For more information: www.moeller.net

EC axial
S series
Q-motor
for wall installation

Repair switch, lockable (available from Möller Electric GmbH)

ESM
Designation Installation

T0-2-8900/I1/SVB-SW Wall installation


T0-2-8900/EA/SVB-SW Cabinet installation
EC-SYSTEMS

subject to alterations
Accessories
Technology
Contacts

389
390
Technology

Motors
Impellers

Control technology
Technical parameters & scope

391
414
410
396
392

Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
Technical parameters & scope

High standards for all ebm-papst products


Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best
possible product for your application. Careful monitoring of the market ensures that technical innovations are
reflected in the improvements of our products.
Based on the technical parameters listed below and the ambience you want our product to operate in,
we here at ebm-papst can always work out the best solution for your specific application.

General performance parameters Service life


Any deviations from the technical data and parameters described here The service life of ebm-papst products depends on two major factors:
are listed on the product-specific data sheet. – The service life of the insulation system
– The service life of the bearing system
Type of protection The service life of the insulation system mainly depends on voltage level,
The type of protection is specified in the product-specific data sheets. temperature and ambient conditions, such as humidity and condensation.
The service life of the bearing system depends mainly on the thermal load
Insulation class on the bearing.
The insulation class is specified in the product-specific data sheets. The majority of our products use maintenance-free ball bearings for
any mounting position possible. As an option, sleeve bearings can be
Mounting position used, which is indicated on the product-specific data sheet wherever
The mounting position is specified in the product-specific data sheets. applicable.
The service life L10 of the ball bearings can be taken as approx. 40,000
Condensate discharge holes operating hours at an ambient temperature of 40 °C, yet this estimate
Information on the condensate discharge holes is provided in the can vary according to the actual ambient conditions.
product-specific data sheets. We will gladly provide you with a lifetime calculation taking into account
your specific operating conditions.
Mode of operation
The mode of operation is specified in the product-specific data sheets. Motor protection / thermal protection
Information on motor protection and thermal protection is provided in the
Protection class product-specific data sheets.
The protection class is specified in the product-specific data sheets. Depending on motor type and field of application, the following protective
features are realised:
– Thermal overload protection (TOP), either in-circuit or external
– PTC with electronic diagnostics
– Impedance protection
– Thermal overload protection (TOP) with electronic diagnostics
– Current limitation via electronics
If an external TOP is connected, the customer has to make sure to
connect a conventional trigger device for switching it off.
All fans with 1~ AC voltage are equipped with a TOP that is connected
in the winding circuit.
Products without fitted TOP and without protection against improper use,
a motor protection complying with the valid standards has to be installed.

392
information
General
AC axial fans
AC axial
S series
Left: Endurance test room
Middle: Shock test

AC axial
K series
Right: Chamber test rig

Mechanical strain / performance parameters Legal and normative directives


All ebm-papst products are subjected to comprehensive tests complying The products described in this catalogue are designed, developed and

AC axial
A series
with the normative specifications. In addition to this, the tests also reflect produced in keeping with the standards in place for the relevant product
the vast experience and expertise of ebm-papst. and, if known, the conditions governing the relevant fields of application.

Vibration test Standards

EC axial fans
Vibration tests are carried out in compliance with Information on standards is provided in the product-specific data sheets.
– Vibration test in operation according to DIN IEC 68, parts 2-4
– Vibration test at standstill according to DIN IEC 68, parts 2-4 EMC
Information on EMC standards is provided in the product-specific data
Shock load sheets.

EC axial
S series
Shock load tests are carried out in compliance with Complying with the EMC standards has to be established on the final
– Shock load according to DIN IEC 68, parts 2-27 appliance, as different mounting situations can result in changed EMC
properties.
Balancing quality
Testing the balancing quality is carried out in compliance with Leakage current

Q-motor
– Residual imbalance according to DIN ISO 1940 Information on the leakage current is provided in the product-specific
– Standard balancing quality level G 6.3 data sheets.
Should you require a higher balancing quality level for your specific The measurement takes place according to Fig. D.1 according to
application, please let us know and specify this when ordering your IEC 60990, Fig. 4.
product.

ESM
Approvals
Chemo-physical strain / performance parameters In case you require a specific approval for your ebm-papst product
Should you have questions about chemo-physical strain, please direct (VDE, UL, GOST, CCC, CSA, etc.) please let us know.
EC-SYSTEMS

them to your ebm-papst contact. Most of our products can be supplied with the relevant approval.
Information on existing approvals is provided in the product-specific
Fields of application, industries and applications data sheets.
Our products are used in various industries and applications:
Ventilation, air-conditioning and refrigeration technology, clean room Air performance measurements
Accessories

technology, automotive and rail technology, medical and laboratory tech- All air performance measurements are carried out on inlet-side chamber
nology, electronics, computer and office technology, telecommunications, test rigs in conformity with the requirements of DIN 24163 and ISO 5801.
household appliances, heating, machines and plants, drive engineering. The fans being tested are installed on the measuring chamber at free air
Our products are not designed for use in the aviation and aerospace intake and discharge (installation type A according to DIN 24163 Part 1)
industry! and are operated at nominal voltage (for AC, also at nominal frequency)
Technology

without additional attachments such as the guard grille.


As required by the standard, the air performance curves correspond to
an air density of 1.2 kg/m3.
Contacts

393
Room for precision noise measuring

Measurement conditions for air and noise measurement


ebm-papst products are measured under the following conditions:
– Axial and centrifugal fans with direction of air flow "V", without guard
grille and in the wall ring
– Backward curved centrifugal fans, free-running and with inlet nozzle
– Forward curved single and dual inlet centrifugal fans with housing

Noise measurements
All noise measurements are carried out in low-reflective test rooms with
reverberant floor. Thus the ebm-papst acoustic test chambers meet the
requirements of precision class 1 according to DIN EN ISO 3745. For noise
measurement, the fans being tested are placed in a reverberant wall and
operated at nominal voltage (for AC, also at nominal frequency) without
additional attachments such as the guard grille.

Sound pressure level and sound level


All noise levels are measured in conformity to DIN 45635 and
ISO 3744/3745 according to precision class 2 and specified A-weighted.
When the sound pressure level (Lp) is measured, the microphone is on
the intake side of the fan being tested, usually at a distance of 1 m on
the fan axis.
To measure the sound level (Lw), 10 microphones are distributed over
an enveloping surface on the intake side of the fan being tested
(see graphic). The sound level measured can be roughly calculated
from the sound pressure level by adding 7 dB.
1,5d

Measurement configuration according to DIN 45635 T38:


D

10 measuring points
d≥D
h = 1.5d to 4.5d
Measurement area S = 6d2 + 7d (h + 1.5d)
3d
h

2d

394
information
General
AC axial fans
AC axial
S series
AC axial
K series
Curves

AC axial
A series
Adding multiple noise sources with the same level

15
[dB]
Adding 2 noise sources with the same volume results in a level increase
of approx. 3 dB. The noise characteristics of multiple identical fans can
Increase in sound pressure / sound power level

be determined in advance based on the noise values specified in the data


10

EC axial fans
9

sheet. This is shown in the diagram opposite.


Example: 8 A3G800 axial fans are on a condenser. According to the data
sheet, the sound pressure level of a fan is approximately 75 dB(A).
5

The level increase measured from the diagram is 9 dB. Thus the overall
sound level of the installation can be expected to be 84 dB(A).

EC axial
S series
0

1 2 5 8 10 15 20 25

Number of sources of sound with identical level

Adding two noise sources with different levels


3
[dB]

The acoustic performance of two different fans can be predetermined

Q-motor
based on the sound levels given in the data sheet. This is shown in the
Increase in sound pressure / sound power level

diagram opposite.
2

Example: There is an axial fan A3G800 with a sound pressure level of


1,5

75 dB(A) at the operating point and an axial fan A3G710 with 71 dB(A) in
a ventilation unit. The level difference is 4 dB. The level increase can now

ESM
1

be read in the diagram as approx. 1.5 dB. This means that the overall
sound level of the unit can be expected to be 76.5 dB(A).
EC-SYSTEMS
0

0 4 8 12 16 20 24

Difference in level with two sources of sound [dB]

Inverse square laws


0
[dB]

The sound level is independent of the distance from the noise source.
Conversely, the sound pressure level decreases as distance from the
-10

Accessories

noise source increases. The diagram to the right shows the level decrease
expressed in terms of an output measurement at a distance of 1 m from
Decrease in sound pressure level
-20

the noise source under far-field conditions.


Example: An axial fan A3G800 has a sound pressure level of 75 db(A) at
-26

the operating point. Now, you want to measure the noise characteristics at
-30

Technology

a distance of 20 m. In the diagram to the right, you can now read a


reduction of 26 dB for the 20 m distance.
-40

1 2 5 10 20 50 100

Distance [m]
Contacts

395
Impellers

Impellers made by ebm-papst


Like pumps and compressors, fans and blowers belong to the category of aerodynamic and fluid work machines.
A fan consists of an impeller, a drive motor and a housing for suspension and for guiding the air flow. The blades spaced
along the circumference of the impeller are designed in such a way as to cause the flowing work medium to change
direction, thus passing on pressure and speed energy.

ebm-papst construction designs Application-specific selection parameters


Depending on the geometrical shape of the impeller, there are different When selecting an application-specific fan or blower, the main parameters
construction designs, with their names taken from the main flow to be taken into account are these:
direction in the impeller. – Air flow at given back pressure
– Constructional design
The most important designs are: – Speed/rpm
– Axial fans – Impeller diameter
– Centrifugal fans with backward curved blades – Ambient conditions governing suction and exhaust side
– Single or dual inlet centrifugal blowers with forward curved blades
– Diagonal (mixed flow) fans (a cross between axial and centrifugal fans)

Relevant fields of application of the various construction designs


The different ebm-papst fan and blower designs correspond to the
different fields of application:
– Small back pressures: Axial fans
– High back pressures: Centrifugal fans with backward curved blades
and single or dual inlet centrifugal blowers
– Threshold between axial and centrifugal fans: Diagonal fans

Characteristic curves of the various designs


[Pa]

axial fans
centrifugal fans, backward curved
1200 centrifugal blowers, single inlet
centrifugal blowers, dual inlet
1000 diagonal fans

800

600

400

200

200 500 1000 2000 5000 10000 20000 50000 [m³/h]

396
information
General
AC axial fans
AC axial
S series
AC axial
K series
Axial fans

Operating range
Noise / efficiency curve
To the right of the "saddle" (right part of the air performance curve):

AC axial
A series
– Maximum efficiency

[%]
[dB(A)]
[Pa]
– Minimal noise
To the left of the "saddle" (left part of the air performance curve):
– Stall area

EC axial fans
– Drop in efficiency
– Soaring noise
The optimum operating range of the fan is shaded in green in the
curve given here.

EC axial
S series
stall area optimum operating range
0

[m³/h]

Q-motor
Direction of air flow
The direction of air flow is given as follows:

Direction of air flow "V" Direction of air flow "A"

ESM
EC-SYSTEMS

 "V" "A" 
Accessories
Technology
Contacts

397
Effects when mounted in wall ring or in the aperture
Curve
Mounting the fan in a wall ring can significantly increase the air
performance in the operating range.

[%]
[Pa]
1

1 Wall ring 2 Aperture

2 1
0

[m³/h]

Effects with axial position in the wall ring


Curve
Axial position in the wall ring influences air performance and efficiency.
[%]
[Pa]

2
1 Projecting on 2 Flush on 3 Immersed on
inlet side inlet side inlet side
x/D=7% x/D=0% x / D = -7 % 1 3

x x x

1
D

3 2
0

[m³/h]

398
information
General
AC axial fans
AC axial
S series
AC axial
K series
Effects with guard grilles
Curve
Mounting a guard grille reduces the air performance of the axial fan.

AC axial
A series
[%]
[Pa]
1 Without guard grille 1

2 With guard grille


2

EC axial fans
2 1

EC axial
S series
0

[m³/h]

Q-motor
The pressure drop in Pa can be roughly calculated according to the Diameter D Correction factor GG
following equation: 130 10000
∆pGG = GG . 10-8 . V2 V in [m3/h] 143 6600
180 2550

ESM
200 1650
For the guard grilles used at ebm-papst, the correction factor GG can be 250 650
used depending on the impeller diameter D from the table to the right. 300 300
315 240
350 150
EC-SYSTEMS

400 90
450 55
500 35
560 20
630 11
Accessories

710 6
800 3
910 1.5
990 0.9
Technology
Contacts

399
Effects of obstructions on the suction or exhaust side
Curve
Disturbances or obstructions on the suction or pressure side reduce
the air performance of the axial fan.

[Pa] 1

Obstructions on the inlet side


1 x/D= 
2 x / D = 35 %
2
3 x / D = 18 %
4 x/D= 9% 3
X
5 x/D= 5%
D

5
0

[m³/h]

Obstructions on the exhaust side


[Pa]

1 x/D= 
2 x / D = 35 %
3 x / D = 18 %
4 x/D= 9%
X
5 x/D= 5%
D

5 4 3 1
0

[m³/h]

400
information
General
AC axial fans
AC axial
S series
Centrifugal fans with backward curved blades

AC axial
K series
Operating range
Noise / efficiency curve
Middle part of air performance curve:

AC axial
A series
– Maximum efficiency

[%]
[dB(A)]
[Pa]
– Minimal noise
To the right and the left of the middle part of the air performance curve:
– Reduced efficiency

EC axial fans
– Increasing noise
The optimum operating range of the fan is shaded in green in the curve
given here.

EC axial
S series
optimum operating range
0

[m³/h]

Q-motor
Effects of nozzle gap dimension
Curve
The centrifugal air gap between the inlet nozzle and impeller cover plate
influences the air performance and efficiency of the centrifugal fan.
[%]
[Pa]

ESM
1 s / D = 0.4 %
2 s / D = 1.0 %
3 s / D = 1.4 %
S

EC-SYSTEMS

3 2 1
Accessories
D

3 2 1
0

[m³/h]
Technology
Contacts

401
Effects of overlapping dimension
Curve
The axial overlap between the inlet nozzle and impeller cover plate
influences the air performance and efficiency of a centrifugal fan.

[%]
[Pa]
1

2
3
1 x / D = 0.6 %
2 x/D= 0 %
X
3 x / D = -0.8 %
1
3 2
D

[m³/h]

Effects of installation space


Curve
When mounting our product in a rectangular box, air performance
might be reduced.
1,00
0,99

B
0,98
0,97
0,96
0,95
Correction factor for air flow

0,5xD
H

0,94
D

0,93
0,92

1,4 1,6 1,8 2,0 2,2 2,4 2,6 2,8

Hydraulic diameter dh/D


dh = Hydraulic diameter
Formula: dh = 2 x B x H / (B + H)
B = Width of box
H = Height of box
D = Outer diameter of the fan

402
information
General
AC axial fans
AC axial
S series
AC axial
K series
Air flow measurement for inlet nozzles
with pressure-measuring point

AC axial
A series
The differential pressure approach compares the static pressure before
the inlet nozzle with the static pressure inside the inlet nozzle.

EC axial fans
0,5xD
D

EC axial
S series
Air flow can be calculated on the basis of the differential pressure

Q-motor
(difference in pressure of the static pressures) in keeping with the
following equation:
V = k . ∆p W V in [m3/h] and ∆pW in [Pa]
If constant air flow control is used, then the nozzle pressure has to be
kept constant: ∆pW = V2 : k2

ESM
k takes into account the specific nozzle characteristics.

One or four pressure measuring points are spaced along the


EC-SYSTEMS

circumference of the inlet nozzle. Connection on the customer side


is accomplished via a premounted T tube connector. This tube connector
is suited for pneumatic hoses with an internal diameter of 4 mm.
Accessories
Technology
Contacts

403
Single and dual inlet centrifugal blowers
with forward curved blades

The forward curved centrifugal impeller must always be operated inside


a scroll housing.
A dual inlet centrifugal blower shows the same behaviour as two single
inlet blowers operated in parallel: with size, speed and pressure being
identical, double the air flow is achieved.

Operating range
Noise / efficiency curve
Middle part of air performance curve:
– Maximum efficiency

[%]
[dB(A)]
[Pa]

– Minimal noise
– Higher performance density than with the backward curved
centrifugal fan
To the right and the left of the middle part of the air performance curve:
– Reduced efficiency
– Increasing noise
The optimum operating range of the fan is shaded in green in the curve
given here.

optimum operating range


0

[m³/h]

Dimensioning of the scroll


The dimensions of a typical scroll can be calculated with the following
formulae, subject to the impeller diameter D:
A = 1.062 · D
J
B = 0.992 · D
C = 0.922 · D
K
A

D = 0.853 · D
B

E = 0.784 · D
45˚ R
H F = 0.715 · D
45˚

C
26˚

G G = 0.646 · D
45˚

45˚

H = 0.612 · D
45˚ 45˚
D

J = 0.720 · D
F
E

K = 0.689 · D
R = 0.073 · D
Adjusting the dimensions to diminished mounting spaces is possible.

404
information
General
AC axial fans
AC axial
S series
AC axial
K series
Effects of step diffusers
Curve
A diffuser mounted on the exhaust side with connected exhaust tunnel

AC axial
A series
increases air performance and efficiency of the centrifugal blower.

[%]
[Pa]
1 without step diffuser 2 with step diffuser

EC axial fans
1 2

EC axial
S series
0

[m³/h]

Q-motor
Effects of obstructions on the intake side
Curve
Obstructions on the air intake side reduce the air performance of the
centrifugal blower.
[Pa]

ESM
1 x/D= 
2 x / D = 30 %
3 x / D = 23 % EC-SYSTEMS
4 x / D = 15 %
5 x / D = 7.5 %
D

X X
Accessories

5 4 3 2 1
0

[m³/h]
Technology
Contacts

405
Effects caused by obstructions on the inlet side for constant air flow
EC centrifugal blowers
Constant air flow is attained with unimpaired inflow only.
An obstructed (e. g. asymmetrical or partially blocked) air flow can have a
significant effect on the curve behaviour and cause large deviations from
a constant air flow curve.

Examples of obstructed inflows

Instructions for designing a sufficiently unobstructed inflow:


– The distance x between the blower intake and neighbouring walls or
obstructions should be at least 25 % of the impeller diameter.
– Inflows with angular momentum or asymmetrical rotation should be
avoided.
– The inflow can be made more uniform using resistances such as those
from filters or grilles.

On request, we offer calibrated blower designs that incorporate a specific


installation situation.

406
information
General
AC axial fans
AC axial
S series
AC axial
K series
Diagonal fans (axial design)

Operating range
Noise / efficiency curve
Directly to the right of the "saddle" (right part of the air

AC axial
A series
performance curve):

[%]
[dB(A)]
[Pa]
– Maximum efficiency
– Minimal noise
To the left of the "saddle" (left part of the air performance curve):

EC axial fans
– Stall area
– Drop in efficiency
– Soaring noise

The saddle of the diagonal/mixed flow fan is slightly higher than that

EC axial
S series
of the axial fan. This means that the technical ratings in the optimal
stall area optimum operating range
operating range are better than those of the axial fan.
0

0
The optimum operating range of the fan is shaded in green in the
[m³/h]
curve given here.

Q-motor
Mounting information
The conical housing (part of delivery) makes sure the necessary gap
dimension is kept.

ESM
Effects
The effects of the diagonal/mixed flow fan are similar to those listed
for the axial fan (p. 397-400). EC-SYSTEMS
Accessories
Technology
Contacts

407
Dimensioning / change in speed

Curve

Influence of speed n

160
[%]

140
A change in speed influences:
1.4n
– Air flow V 120 1.3n

V~n 1.2n
100

1.1n
– Static pressure increase pfa
n
80

∆pfa ~ n2 0.9n

– Requirement of energy P1
60

0.8n

P1 ~ n3 0.7n
40

0.6n
20
0

0 20 40 60 80 100 120 140

[%]

Curve

Influence of the speed n on the sound level Lw


[dB]

When the speed changes, the approximate sound level can be


20

determined using the diagram to the right and the following formula:
Lw - Lw = 50 dB . log (n : n )
2 1 2 1
10
modification in sound pressure level

Lw1 = Sound level after speed change


0

Lw2 = Sound level before speed change


n1 = Changed speed
-10

n2 = Starting speed
-20

0,5 1 1,5 2 2,5 3

factor of speed change

408
information
General
AC axial fans
AC axial
S series
AC axial
K series
Curve

AC axial
A series
Influence of impeller diameter D

160
[%]
1.3D

140
A change in impeller diameter influences:
– Air flow V 120
1.2D

V~ D3

EC axial fans
1.1D
100

– Static pressure increase ∆pfa


D
80

∆pfa ~ D2 0.9D
– Requirement of energy P1
60

0.8D

P1 ~ D5 0.7D
40

0.6D

EC axial
S series
20
0

0 20 40 60 80 100 120 140

[%]

Q-motor
Curve

Influence of width of air discharge b (only for centrifugal impellers)


160
[%]

140

A change in width of the air discharge influences, in approximation:

ESM
– Air flow V
120

V~b
100

– Static pressure increase ∆pfa


80

EC-SYSTEMS
∆pfa = const
60

– Requirement of energy P1
0.7b 0.9b 1.1b 1.3b
0.6b 0.8b b 1.2b 1.4b
P1 ~ b
40
20

Accessories
0

0 20 40 60 80 100 120 140

[%]
Technology
Contacts

409
Motors

Motors made by ebm-papst


In AC and EC technology, ebm-papst relies on the proven external-rotor motor principle, with the rotor turning
around the stator within. Advantages of the ebm-papst external-rotor principle are:
– Space saving design due to integrated bearings and direct installation inside the impeller
– Lower load and more precise balancing of the bearing due to the fixed connection of all rotating elements
– Prolonged service life due to the motor-impeller unit placed right within the air flow
The ebm-papst motors achieve very good results in efficiency and acoustic behaviour when used in EC technology.

Features AC motors EC motors


Shaded-pole motor Single-phase 3-phase motor Single-core motor 3-core motor
capacitor motor

1 ~ AC voltage Limited use


Yes Yes Yes Yes
connector (Steinmetz circuit)

3 ~ AC voltage
No No Yes No Yes
connector

DC voltage
No No No Yes Yes
connector

Electronics Electronics
(see p. 418) (see p. 418)

Design of
circuit diagram
- Stator -

Steinmetz circuit

Rotor principle Squirrel cage Squirrel cage Squirrel cage Magnetic rotor Magnetic rotor

Efficiency Low Medium Good Excellent Excellent

Continuous speed
No No No Yes Yes
setting integrated

Noise behaviour Medium Good Excellent Medium Excellent

410
information
General
AC axial fans
AC axial
S series
AC axial
K series
AC motors

AC motors (induction motors) are based in their function on the principle Shaded-pole motor
of the asynchronous rotation of the stator rotating field and rotor. Each pole of the motor is divided electro-magnetically into a main

AC axial
A series
and auxiliary pole (split) via a cage winding in order to generate a
Torque curves of the motor types starting torque.
At ebm-papst, shaded-pole motors are available as 2 or 4-pole
[Ncm]

2 symmetrical external or internal rotor designs.

EC axial fans
1

MK

EC axial
S series
4
M Sa
5
M St
Advantages:
– Extremely robust motor design due to cast squirrel cage rotor

Q-motor
and stable bearing system
Key: – Cost-efficient motor
1 - EC motor 5 - System characteristic – Extremely easy to connect
2 - 3-phase motor MSt - Starting torque
– Long service life
3 - Single-phase motor MSa - Saddle torque

ESM
4 - Shaded-pole motor MK - Breakdown torque

Start-up current
EC-SYSTEMS

The start-up current of our AC motors is maximally 4x higher than the


nominal current given.
Accessories
Technology
Contacts

411
Single-phase capacitor motor 3-phase motor
Two cores (main winding MW and auxiliary winding AW) generate The three motor cores are offset by 120° and generate a circular rotating
the rotating field of the single-phase capacitor motor via a capacitor field when connected to the 3-phase mains.
connected in series to form an auxiliary winding.
c ≈ 70 µF/kW
(230 VAC ∆)

Star Delta Steinmetz circuit

Advantages:
Advantages: – Extremely robust motor design due to cast squirrel cage rotor
– Extremely robust motor design due to cast squirrel cage rotor and stable bearing system
and stable bearing system – Very good vibration and noise behaviour
– Diverse options for setting speed – Efficiency between 40 % and 80 % (depending on the motor size)
– Efficiency between 30 % and 75 % (depending on motor size) – Long service life
– Long service life
– Good vibration and noise behaviour
Torque curves of 3-phase motors
[Ncm]

Key:
1 - Delta 3 - Steinmetz circuit
2 - Star

412
information
General
AC axial fans
AC axial
S series
AC axial
K series
EC motors

EC motors are based in their function on the principle of the Single-core motor
synchronous rotation of stator rotating field and rotor.

AC axial
A series
Torque curves of the motor types Electronics
[Ncm]

EC axial fans
1

Advantages:
MK – Integrated speed setting

EC axial
S series
– Efficiency between 50 % and 80 % (depending on the motor size)
4
– Long service life
M Sa
5
M St

Q-motor
3-core motor
Key:
1 - EC motor 5 - System characteristic
2 - 3-phase motor MSt - Starting torque Electronics
3 - Single-phase motor MSa - Saddle torque

ESM
4 - Shaded-pole motor MK - Breakdown torque

EC-SYSTEMS

Advantages:
– Integrated speed setting
– Good efficiency between 60 % and 90 %
(depending on the motor size)
Accessories

– Long service life


– Very good vibration and noise behaviour even in
controlled operation
– Can be used as drive motor
Technology
Contacts

413
Control technology

Open and closed loop control using ebm-papst technology


Depending on the field of application, fan speed has to be adjusted. In AC technology, the speed setting option can
result in an increase in installation expenditure and, typically, a less favourable noise performance and an increase in
power input.
Here, ebm-papst EC technology is a more eco-friendly and cost-efficient alternative. The EC motor with integrated
commutation electronics offers high efficiency across the entire speed range and optimal acoustic performance
at minimal installation expenditure.

Features AC EC commutating electronics


Phase-angle control

Phase-angle control

Frequency inverter

Frequency inverter
Series resistance

Speed stepping

Integrated with
with sine filter

with sine filter

switch power
Transformer

Integrated

External
supply
Installation + – + – – – – ++ – –
Noise behaviour + ++ – –– – – + ++ + +
Power input –– – – – – + + ++ + +
Service life + + – – + – + + + +
+ = positive + + = very positive – = negative – – = very negative

Acoustic performance of controlled motors Power input of controlled motors


[dBA]

[W]

70
1500
60

50 1000

40
500
30

0 1000 2000 3000 4000 5000 6000 [CFM] 0 1000 2000 3000 4000 5000 6000 [CFM]

2000 4000 6000 8000 10000 [m³/h] 2000 4000 6000 8000 10000 [m³/h]

Key: Key:
ebm-papst EC controls ebm-papst EC controls
Frequency inverter with sine filter Frequency inverter with sine filter
Phase-angle control without sine filter Phase-angle control without sine filter
Phase-angle control with sine filter Phase-angle control with sine filter
Transformer Transformer

414
information
General
AC axial fans
AC axial
S series
AC axial
K series
Speed setting with AC motors

Speed setting helps to optimise power input When selecting a voltage controller, note that the nominal current in the
and the flow noise as requested. partial load range can be up to 20 % (depending on the controller) above

AC axial
A series
the specified maximum current.

Series resistance
C – Fixed speed steps

EC axial fans
R1
AW ASM – Speed setting via change in motor voltage
1~
0
1
R2 – Cost-efficient
2 MW
L1
3 – Small capacities
N Note: Capacitors or chokes reduce the loss capacity.
PE

EC axial
S series
Transformer
L1
C – Fixed speed steps
4
Tr 3
AW ASM – Speed setting via change in motor voltage
2 1~
1

Q-motor
MW

PE

Phase-angle control

ESM
C – Continuous speed setting
AW ASM – Speed setting via change in motor voltage
1~
– Cost-efficient
MW
Tr – Acoustic performance and warming has to be reviewed
EC-SYSTEMS
L1

N in the application
PE

Frequency inverter with sine filter


Accessories

T1 T3 T5
ASM – Continuous speed setting
3~

L1
– Speed setting via change in frequency of rotating field
U
+ U
L2
V V W
– High efficiency
L3
W
Note: An all-pole sine filter (phase-phase and phase-earth)
T2 T4 T6
has to be used.
Technology

PE
Contacts

415
Electrical connections AC

Fans (1~ 230 VAC power line) Fans, 1 speed (3~ 230 VAC power line)

A1) Single-phase capacitor motor B) Shaded pole motor C1) Delta connection (3~ 230 VAC power system)
with TOP wired internally with TOP wired internally without TOP

L PE N U1 = blue L PE N L = blue PE L1 L2 L3 U1 = black


C
U2 = black N = brown U2 = green
Z = brown = green/ U1 V1 W1 V1 = blue
U1 U2 Z = green/ yellow V2 = white
yellow W1 = brown
U2 V2 W2 W2 = yellow
TOP TOP = green/
yellow

A2a) Single-phase capacitor motor D1) Delta connection (3~ 230 VAC power line)
with connection for external TOP with TOP

L PE N U1 = blue PE L1 L2 L3 TOP U1 = black


C TOP U2 = green
U2 = black
Z = brown U1 V1 W1 V1 = blue
U1 U2 Z V2 = white
= green/
yellow W1 = brown
U2 V2 W2
W2 = yellow
= green/
yellow

A2b) Single-phase capacitor motor Direction of rotation is reversed by swapping


with connection for external TOP two line phases.

U1 = blue
C U2 = black
Z = brown
U1 Z U2 TOP TOP
= green/
L N PE yellow

Fans
with terminal box

416
information
General
AC axial fans
AC axial
S series
AC axial
K series
Fans, 1 speed (3~ 400 VAC power line) Fans, 2 speeds via ∆/Y-switch (3~ 400 VAC power line)

AC axial
A series
C2) Star connection (3~ 400 VAC power system) E1) Delta connection (high speed) E2) Star connection (low speed)
without TOP without TOP without TOP

PE L1 L2 L3 U1 = black PE L1 L2 L3 U1 = black PE L1 L2 L3 U1 = black

EC axial fans
U2 = green U2 = green U2 = green
V1 = blue U1 V1 W1 V1 = blue V1 = blue
U1 V1 W1 U1 V1 W1
V2 = white V2 = white V2 = white
W1 = brown W1 = brown W1 = brown
U2 V2 W2 W2 = yellow U2 V2 W2 W2 = yellow U2 V2 W2 W2 = yellow
= green/ = green/ = green/
yellow yellow yellow

EC axial
S series
D2) Star connection (3~ 400 VAC power line) F1a) Delta connection (high speed) F2a) Star connection (low speed)
with TOP with TOP with TOP

U1 = black U1 = black U1 = black

Q-motor
PE L1 L2 L3 TOP PE L1 L2 L3 TOP PE L1 L2 L3 TOP
U2 = green U2 = green U2 = green
U1 V1 W1 V1 = blue U1 V1 W1 V1 = blue U1 V1 W1 V1 = blue
V2 = white V2 = white V2 = white
W1 = brown W1 = brown W1 = brown
U2 V2 W2 U2 V2 W2 U2 V2 W2
W2 = yellow W2 = yellow W2 = yellow
= green/ = green/ = green/

ESM
yellow yellow yellow

Direction of rotation is reversed by swapping F1b) Delta connection (high speed) F2b) Star connection (low speed)
two line phases. with TOP with TOP
EC-SYSTEMS

U1 = black U1 = black
U2 = green U2 = green
V1 = blue V1 = blue
U1 V1 W1 W2 U2 V2 TOP TOP U1 V1 W1 W2 U2 V2 TOP TOP
V2 = white V2 = white
L1 L2 L3 PE W1 = brown L1 L2 L3 PE W1 = brown
Accessories

W2 = yellow W2 = yellow
Fans = green/ Fans = green/
with terminal box yellow with terminal box yellow

Direction of rotation is reversed by swapping two line phases.


Technology
Contacts

417
Speed setting with EC motors

The speed of EC motors is set via commutation electronics. Via electronic


circuits and depending on the rotor position, this commutation switches
the motor currents on and off.

Principle of AC-fed commutation electronics Principle of DC-fed commutation electronics

Interface Control unit Power unit Interface Control unit Power unit
EMC filter
0-10 VDC 0-10 VDC
PWM DC/DC transformer PWM
EMC filter
Commutations unit
Rectifier

Commutations unit
Feedback Feedback
Link electrolytic capacitor

Inverter stage
CAN CAN
LON LON
Drive
Inverter stage
Drive
RS485 RS485

(with electrically isolated interface)

Integrated commutation electronics


– Compact unit
AC
– Easy to install
– Low installation expenditure
– Can be operated all over the world
Note: Motors with 12-72 VDC supply voltage have to be fed via
electrically isolated supply unit.
DC

Integrated commutation electronics with switch power supply


– Protective extra-low voltage 24 / 48 VDC AC
Note: Switch power supply is not included but has to be ordered
as accessory. DC

418
information
General
AC axial fans
AC axial
S series
AC axial
K series
Types of alarms and reactions with EC motors
Typical features of the ebm-papst commutation electronics:
With DC-fed EC motors, certain faults in modes of operation are

AC axial
A series
– Input for analogue and digital signals
recognised by the electronics, and the motor is automatically restarted.
– Open and closed loop control as well as monitoring of the motor
With AC-fed EC motors, certain faults in modes of operation are
– Integrated EMC filter
recognised by the electronics, and the motor is switched off.
– High efficiency throughout the entire speed range
The motor restarts automatically after the following failures have been

EC axial fans
– Speed setting via linear set value (0-10 VDC) or PWM signal
diagnosed:
– Low-noise operation across the entire speed range
– Line failure
– Minimal extra costs for additional functions
– Phase failure
(open/closed loop control)
– Line under-voltage
– Optional BUS interface
– DC link voltage too high or too low

EC axial
S series
– Locked rotor
With the following types of failures, there is no automatic restart.
Here, hardware or software reset is required:
– Motor temperature too high
– Temperature of cooling element or ambient temperature of

Q-motor
electronics too high
– Hall failure

Hardware reset
Switching off the fan and restarting it after one minute results in

ESM
hardware reset.

Software reset
EC-SYSTEMS

Software reset is via ebmBUS and LISA software, hand-held control


terminal, or PDA with Fan Control Software.
Accessories
Technology
Contacts

419
Electrical connections EC

G) EC motors (nominal voltage 24 / 48 VDC)


Notes on various control possibilities and their applications
Maximum ripple
± 3.5%
red

33 K 4.7 K
Lin/PWM control input
0-10 VDC / PWM
yellow
Counter

Tach output Isink max. 10 mA


Controller
U pulses per revolution
PWM
10 K white 680 
Alarm

12 V 12 V Speed display
47 V

GND
Temperature Speed setting Speed setting Full speed Speed setting blue
control module with
PWM 1 - 10 kHz potentiometer 1 V - 10 V
50002-1-0174
50003-1-0174
100% PWM -> n=max 10 V -> n=max
approx. 10% PWM -> n=min approx. 1 V -> n=min
< 10% PWM -> n=0 < 1 V -> n=0

start up at > 1.4 V start up at > 1.4 V

Customer circuit Connection Fan

Line 1
0-10 V
PWM
Tach
GND
+

red blue white yellow

Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 + red Maximum ripple ± 3.5 % 1 Tach white Tach output:
GND blue GND 2 pulses / revolution (M1G045 / M1G055)
3 pulses / revolution (M1G074/M3G084)
0-10 V / PWM yellow Control input (Impedance 100 k)

420
information
General
AC axial fans
AC axial
S series
AC axial
K series
H1) EC motors (size 055, line-fed)

AC axial
A series
Notes on various control possibilities and their applications
Umin = 15 V

Imax = L
10 mA Mains brown +
50/60 Hz N
blue -

EC axial fans
PE
green/yellow

+
PWM U Voltage output
+10 V max. 1.1 mA
10 K -
red

EC axial
S series
12 V
Lin/PWM control input
0-10 VDC / PWM
yellow

1 F
GND
blue
Counter

Q-motor
Speed setting Speed setting Full speed Speed setting Tach output
with variable 1 pulse per revolution Isink max. 10 mA
PWM 1 - 10 kHz resistance 1 V - 10 V
Controller white 680 
47 V
100% PWM -> n=max 10 V -> n=max
approx. 10% PWM -> n=min approx. 1 V -> n=min Alarm
< 10% PWM -> n=0 < 1 V -> n=0

start up at > 1.4 V start up at > 1.4 V Speed display

ESM
Customer circuit Connection Fan

Line 1 Line 2 EC-SYSTEMS


0-10 V
+10 V

PWM

Tach
GND
PE
N
L

brown blue green/yellow red yellow blue white

Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 L brown Mains 50/60 Hz, phase 2 +10 V red Voltage output +10 V max. 1.1 mA
N blue Mains 50/60 Hz, neutral 0-10 V / PWM yellow Control input (Impedance 100 k)
Accessories

PE green/yel Protective earth GND blue GND


Tach white Tach output: 1 pulse per revolution
Technology
Contacts

421
H2) EC motors (size 055, line-fed and constant air flow)
Notes on various control possibilities and their applications
Umin = 15 V

Imax = L
10 mA Mains brown +
50/60 Hz N
blue -
PE
green/yellow

+
PWM U Voltage output
+10 V max. 1.1 mA
10 K -
red
12 V Lin/PWM input
for set value
0-10 VDC / PWM
yellow

1 F
GND
blue
Air flow setting Air flow setting Max. Air flow setting Counter
Tach output
with variable air flow 1 pulse per revolution Isink max. 10 mA
PWM 1 - 10 kHz resistance 1 V - 10 V
Controller white 680 
47 V
100% PWM -> Vmax 10 V -> Vmax
17% PWM -> Vmin 1.7 V -> Vmin Alarm
< 15% PWM -> V= 0m3/h < 1.5 V -> V= 0m3/h

start up at > 1.4 V start up at > 1.4 V Speed display

Customer circuit Connection Fan

Line 1 Line 2
0-10 V
+10 V

PWM

Tach
GND
PE
N
L

brown blue green/yellow red yellow blue white

Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 L brown Mains 50/60 Hz, phase 2 +10 V red Voltage output +10 V max. 1.1 mA
N blue Mains 50/60 Hz, neutral 0-10 V / PWM yellow Input for set value (impedance 100 k)
PE green/yel Protective earth GND blue GND
Tach white Tach output: 1 pulse per revolution

422
information
General
AC axial fans
AC axial
S series
AC axial
K series
J1) EC motors (size 074, line-fed)

AC axial
A series
Notes on various control possibilities and their applications
Umin = 15 V

Imax = L
10 mA Mains black +
50/60 Hz N
blue -

EC axial fans
PE
green/yellow

+
PWM U Voltage output
+10 V max. 1.1 mA
10 K -
red

EC axial
S series
12 V
Lin/PWM control input
0-10 VDC / PWM
yellow

1 F
GND
blue
Counter

Q-motor
Speed setting Speed setting Full speed Speed setting Tach output
with variable 1 pulse per revolution Isink max. 10 mA
PWM 1 - 10 kHz resistance 1 V - 10 V
Controller white 680 
47 V
100% PWM -> n=max 10 V -> n=max
approx. 10% PWM -> n=min approx. 1 V -> n=min Alarm
< 10% PWM -> n=0 < 1 V -> n=0

start up at > 1.4 V start up at > 1.4 V Speed display

ESM
Customer circuit Connection Fan

Line 1 Line 2 EC-SYSTEMS


0-10 V
+10 V

PWM

Tach
GND
PE
N
L

black blue green/yellow red yellow blue white

Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 L black Mains 50/60 Hz, phase 2 +10 V red Voltage output +10 V max. 1.1 mA
N blue Mains 50/60 Hz, neutral 0-10 V / PWM yellow Control input (Impedance 100 k)
Accessories

PE green/yel Protective earth GND blue GND


Tach white Tach output: 1 pulse per revolution
Technology
Contacts

423
J2) EC motors (size 074, line-fed and constant air flow)
Notes on various control possibilities and their applications

L
Mains black +
50/60 Hz N
10 K blue -
PE
green/yellow

+
PWM U Voltage output
+10 V max. 1.1 mA
10 K -
red
12 V Lin/PWM input
for set value
0-10 VDC / PWM
yellow

1 F
GND
blue
Speed setting Air flow setting Max. Air flow setting Counter
Tach output
with variable air flow 1 pulse per revolution Isink max. 10 mA
PWM 1 - 10 kHz resistance 1 V - 10 V
Controller white 680 
47 V
100% PWM -> V=max 10 V -> V=max
approx. 17% PWM -> V=min approx. 1.7 V -> V=min Alarm
< 15% PWM -> V=0 < 1.5 V -> V=0

start up at > 1.4 V start up at > 1.4 V Speed display

Customer circuit Connection Fan

Line 1 Line 2
0-10 V
+10 V

PWM

Tach
GND
PE
N
L

black blue green/yellow red yellow blue white

Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 L black Mains 50/60 Hz, phase 2 +10 V red Voltage output +10 V max. 1.1 mA
N blue Mains 50/60 Hz, neutral 0-10 V / PWM yellow Input for set value (impedance 100 k)
PE green/yel Protective earth GND blue GND
Tach white Tach output: 1 pulse per revolution

424
information
General
AC axial fans
AC axial
S series
AC axial
K series
K1) EC motors (size 084, line-fed)

AC axial
A series
Notes on various control possibilities and their applications
Umin = 15 V

Imax = L
10 mA Mains black +
50/60 Hz N
blue -

EC axial fans
PE
green/yellow

NC
Alarm relay:
white1
Break for failure
+ COM
(2 A, 250 VAC, AC1)
PWM U white2
- Voltage output
10 K
red +10 V

EC axial
S series
max. 1.1 mA
12 V

Lin/PWM control input


yellow 0-10 VDC /
PWM
1 F
GND
blue

Q-motor
Speed setting Speed setting Full speed Speed setting
with variable
PWM 1 - 10 kHz resistance 1 V - 10 V

100% PWM -> n=max 10 V -> n=max


approx. 10% PWM -> n=min approx. 1 V -> n=min
< 10% PWM -> n=0 < 1 V -> n=0

start up at > 1.4 V start up at > 1.4 V

ESM
Customer circuit Connection Fan

Line 1 Line 2 EC-SYSTEMS


0-10 V
+10 V

PWM
COM

GND
NC
PE
N
L

black blue green/yellow white1 white2 red yellow blue

Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 L black Mains 50/60 Hz, phase 2 +10 V red Voltage output +10 V max. 1.1 mA
N blue Mains 50/60 Hz, neutral 0-10 V / PWM yellow Control input (Impedance 100 k)
Accessories

PE green/yel Protective earth GND blue GND


NC white1 Alarm relay, break for failure
COM white2 Alarm relay, COMMON
Technology
Contacts

425
K2) EC motors (size 084/112 with ebmBUS, mains-powered)
KL1 KL2

+15 V
RS B

RS A

0V
PE

Connector Connection Assignment / function Connector Connection Assignment / function


KL1 PE Protective earth KL2 RS B RS485 interface for ebmBUS; RS B
N Mains 50/60 Hz, neutral RS A RS485 interface for ebmBUS; RS A
L Mains 50/60 Hz, phase +15 V Operation: +15 V (50 mA); Alarm: 0 V
0V Operation: 0 V; Alarm: +15 V (50 mA)

426
information
General
AC axial fans
AC axial
S series
AC axial
K series
L1) EC motors (size 112, single-phase mains-powered)

AC axial
A series
KL3 KL2 KL1
4-20 mA
0-10 V

0-10 V
+20 V

+10 V
PWM

PWM
RS B

RS B

COM
RS A

RS A

GND

GND

OUT

NO

NC

PE
N
L
Connector Connection Assignment / function Connector Connection Assignment / function

EC axial fans
PE PE Protective earth KL3 OUT Master output 0-10 V max. 3 mA
KL1 N Mains 50/60 Hz, neutral GND GND
L Mains 50/60 Hz, phase 0-10 V / PWM Control / Actual value input (Impedance 100 k)
KL2 NC Alarm relay, break for failure +10 V Supply for external potentiometer,
COM Alarm relay, COMMON (2A, 250 VAC, AC1) 10 VDC (+10 %) @ 10 mA
NO Alarm relay, make for failure +20 V Supply for external sensor,

EC axial
S series
20 VDC (±20 %) @ 50 mA
4-20 mA Control / Actual value input
0-10 V / PWM Control / Actual value input
GND GND
RSB RS485 interface for ebmBUS; RS B
RSA RS485 interface for ebmBUS; RS A

Q-motor
RSB RS485 interface for ebmBUS; RS B
RSA RS485 interface for ebmBUS; RS A

L2) EC motors (size 112, three-phase mains-powered)


KL3 KL2 KL1

ESM
4-20 mA
0-10 V

0-10 V
+20 V

+10 V
PWM

PWM
RS B

RS B

COM
RS A

RS A

GND

GND

OUT

NO

NC

PE
L1

L2

L3

Connector Connection Assignment / function Connector Connection Assignment / function


EC-SYSTEMS

PE PE Protective earth KL3 OUT Master output 0-10 V max. 3 mA


KL1 L3 Mains; L3 GND GND
L2 Mains; L2 0-10 V / PWM Control / Actual value input (Impedance 100 k)
L1 Mains; L1 +10 V Supply for external potentiometer,
KL2 NC Alarm relay, break for failure 10 VDC (+10 %) @ 10 mA
COM Alarm relay, COMMON (2A, 250 VAC, AC1) +20 V Supply for external sensor,
Accessories

NO Alarm relay, make for failure 20 VDC (±20 %) @ 50 mA


4-20 mA Control / Actual value input
0-10 V / PWM Control / Actual value input
GND GND
RSB RS485 interface for ebmBUS; RS B
RSA RS485 interface for ebmBUS; RS A
Technology

RSB RS485 interface for ebmBUS; RS B


RSA RS485 interface for ebmBUS; RS A
Contacts

427
M) EC motors (size 150, three-phase mains-powered)
KL3 KL2 KL1
4-20 mA
0-10 V

0-10 V
+20 V

+10 V
PWM

PWM
RS B

RS B

COM
RS A

RS A

GND

GND

OUT

NO

NC

PE
L1

L2

L3
Connector Connection Assignment / function Connector Connection Assignment / function
PE PE Protective earth KL3 OUT Master output 0-10 V max. 3 mA
KL1 L3 Mains; L3 GND GND
L2 Mains; L2 0-10 V / PWM Control / Actual value input (Impedance 100 k)
L1 Mains; L1 +10 V Supply for external potentiometer,
KL2 NC Alarm relay, break for failure 10 VDC (+10 %) @ 10 mA
COM Alarm relay, COMMON (2A, 250 VAC, AC1) +20 V Supply for external sensor,
NO Alarm relay, make for failure 20 VDC (±20 %) @ 50 mA
4-20 mA Control / Actual value input
0-10 V / PWM Control / Actual value input
GND GND
RSB RS485 interface for ebmBUS; RS B
RSA RS485 interface for ebmBUS; RS A
RSB RS485 interface for ebmBUS; RS B
RSA RS485 interface for ebmBUS; RS A

428
RS A RS A RS A

RS B RS B RS B

PC with interface
converter (RS485)
RS A RS A RS A

RS B RS B RS B

GND GND GND

0-10 V 0-10 V 0-10 V


PWM PWM PWM

4-20 mA 4-20 mA 4-20 mA

sensor
Pressure
+20 V +20 V +20 V

+10 V +10 V +10 V

0-10 V 0-10 V 0-10 V


PWM PWM PWM

GND GND GND

OUT OUT OUT

NO NO NO
Connection diagram: Condensing pressure control with master-slave fans

COM COM COM


Alarm relay

NC NC NC

L1 L1 L1

L2 L2 L2

L3 L3 L3

PE PE PE

Slave
Slave
Master

Mains
Mains
Mains

50/60 Hz
50/60 Hz
50/60 Hz

429
Contacts Technology Accessories EC-SYSTEMS ESM Q-motor EC axial EC axial fans AC axial AC axial AC axial AC axial fans General
S series A series K series S series information
fan agent

compact fan agent


Distributors, agencies and subsidiaries
motor specialist

motor agent

Germany
ebm-papst ebm-papst ebm-papst
Mulfingen GmbH & Co. KG St. Georgen GmbH & Co. KG Landshut GmbH

Bachmühle 2 Hermann-Papst-Straße 1 Hofmark-Aich-Straße 25


D-74673 Mulfingen D-78112 St. Georgen D-84030 Landshut
Phone +49 (0) 79 38 / 81-0 Phone +49 (0) 77 24 / 81-0 Phone +49 (0) 8 71 / 707-0
Fax +49 (0) 79 38 / 81-110 Fax +49 (0) 77 24 / 81-13 09 Fax +49 (0) 8 71 / 707-465
info1@de.ebmpapst.com info2@de.ebmpapst.com info3@de.ebmpapst.com

www.ebmpapst.com www.ebmpapst.com www.ebmpapst.com

Contacts Koblenz Distributors


Winfried Schaefer
Berlin Frankfurt
Hinter der Kirch 10
Dipl.-Ing. (TH) Jens Duchow R.E.D. Handelsgesellschaft mbH
D-56767 Uersfeld
Händelstraße 7 Gutenbergstraße 3
Phone +49 (0) 26 57 / 16 96
D-16341 Panketal D-63110 Rodgau - Jügesheim
Fax +49 (0) 26 57 / 16 76
Phone +49 (0) 30 / 94 41 49 62 Phone +49 (0) 61 06 / 84 10
Winfried.Schaefer@de.ebmpapst.com
Fax +49 (0) 30 / 94 41 49 63 Fax +49 (0) 61 06 / 84 11 11
Jens.Duchow@de.ebmpapst.com Munich info@red-elektromechanik.de
Dipl.-Wirt.-Ing. (FH) Jens Peter www.red-elektromechanik.de
Dortmund
Steinbergweg 6
Dipl.-Ing. (FH) Hans-Joachim Pundt Hamburg
D-82285 Hattenhofen
Auf den Steinern 3 Breuell + Hilgenfeldt GmbH
Phone +49 (0) 81 45 / 80 92 25
D-59519 Möhnesee-Völlinghausen Grützmühlenweg 40
Fax +49 (0) 81 45 / 80 92 26
Phone +49 (0) 29 25 / 80 04 07 D-22339 Hamburg
Jens.Peter@de.ebmpapst.com
Fax +49 (0) 29 25 / 80 04 08 Phone +49 (0) 40 / 53 80 92 20
Hans-Joachim.Pundt@de.ebmpapst.com Nuremberg Fax +49 (0) 40 / 53 80 92 84
Friedrich Klein info@breuell.de
Frankfurt
Adlerstraße 49/1
Dipl.-Ing. Christian Kleffmann Munich
D-73540 Heubach
Dr. Hermann-Krause Straße 23 A. Schweiger GmbH
Phone +49 (0) 71 73 / 49 83
D-63452 Hanau Ohmstraße 1
Fax +49 (0) 71 73 / 80 53
Phone +49 (0) 61 81 / 18 98 12 D-82054 Sauerlach
Friedrich.Klein@de.ebmpapst.com
Fax +49 (0) 61 81 / 18 98 13 Phone +49 (0) 81 04 / 8 97 0
Christian.Kleffmann@de.ebmpapst.com Offenburg Fax +49 (0) 81 04 / 8 97 90
Dipl.-Ing (FH) Ralf Braun info@schweiger-gmbh.de
Halle
Hubeneck 21 www.schweiger-gmbh.com
Dipl.-Ing. (TU) Michael Hanning
D-77704 Oberkirch
Lerchenweg 4
Phone +49 (0) 78 02 / 98 22 52 (1 to 5 pieces)
D-06120 Lieskau
Fax +49 (0) 78 02 / 98 22 53
Phone +49 (0) 3 45 / 5 51 24 56 North
Ralf.Braun@de.ebmpapst.com
Fax +49 (0) 3 45 / 5 51 24 57 Breuell + Hilgenfeldt GmbH
Michael.Hanning@de.ebmpapst.com Stuttgart Grützmühlenweg 40
Dipl.-Ing. (FH) Rudi Weinmann D-22339 Hamburg
Hamburg
Mühlhaldenweg 13 Phone +49 (0) 40 / 53 80 92 20
Ingenieurbüro Breuell GmbH
D-73207 Plochingen Fax +49 (0) 40 / 53 80 92 84
Dirk Kahl
Phone +49 (0) 71 53 / 92 89 80 ebm@breuell.de
Elektroingenieur
Fax +49 (0) 71 53 / 92 89 81
Grützmühlenweg 40 South
Rudi.Weinmann@de.ebmpapst.com
D-22339 Hamburg HDS Ventilatoren Vertriebs GmbH
Phone +49 (0) 40 / 53 80 92 10 Ulm Glaswiesenstraße 1
Fax +49 (0) 40 / 53 80 92 84 Günter Wilhelm D-74677 Dörzbach
Dirk.Kahl@de.ebmpapst.com Allgäuer Straße 7 Phone +49 (0) 79 37 / 80 29 68
D-89269 Vöhringen Fax +49 (0) 79 37 / 80 25 78
Kassel
Phone +49 (0) 73 06 / 92 46 08 info@hds-gmbh.net
Dipl.-Ing. (FH) Ralph Brück
Fax +49 (0) 73 06 / 92 46 48
Hoherainstraße 38
Guenter.Wilhelm@de.ebmpapst.com
D-35075 Gladenbach
Phone +49 (0) 64 62 / 40 71 10
Fax +49 (0) 64 62 / 40 71 11
Ralph.Brueck@de.ebmpapst.com

430
information
General
AC axial fans
AC axial
S series
AC axial
K series
Europe Czech Republic / Slovakia Hungary
ebm-papst CZ s.r.o. ebm-papst Industries Kft.
Austria

AC axial
A series
Krátká 379 Mátyás u. 1/A
ebm-papst Motoren & Ventilatoren GmbH
CZ-66461 Rajhradice u Brna H-2220 Vecsés
Westbahnstraße 5
Phone +420 / 5 / 47 23 26 16 Phone +36 / 29 / 55 01 90
A-4490 St. Florian
Fax +420 / 5 / 47 23 26 22 Fax +36 / 29 / 55 01 94
Phone +43 / 72 24 / 66 01 10
info@ebmpapst.cz office@hu.ebmpapst.com
Fax +43 / 72 24 / 66 01 120
www.ebmpapst.cz www.ebmpapst.hu

EC axial fans
info@at.ebmpapst.com
www.ebmpapst.at Denmark Iceland
Jenk A/S RJ Engineers
Belarus
Vallensbækvej 21 Stangarhyl 1A
ebm-papst Bel AgmbH
DK-2605 Brøndby IS-110 Reykjavik
Prospekt Nesavisimosti 11/2 Zimmer 325, 512
Phone +45 / 43 / 63 11 11 Phone +354 / 567 80 30
BY-220050 Minsk
Fax +45 / 43 / 63 05 05 Fax +354 / 567 80 15
Phone +375 / 17 / 209 95 61
jenk@jenk.dk rj@rj.is

EC axial
S series
Fax +375 / 17 / 209 95 61
www.jenk.dk www.rj.is
info@by.ebmpapst.com
Estonia Ireland
Belgium
ebm-papst Oy ebm-papst Limited
VIBO Benelux B. V.
Eesti Filiaal Portlaoise Business & Technology Park
Sales office Belgium-Luxembourg
Kadaka tee 3 Mountrath Road
Romeinsestraat 6/0101
EST-10621 Tallinn IRL-Portlaoise, Co. Laois

Q-motor
Research Park Haasrode
Phone +372 / 655 / 6978 Phone +353 / 57 86 / 643 43
B-3001 Heverlee-Leuven
Fax +372 / 655 / 6979 Fax +353 / 57 86 / 643 46
Phone +32 / 16 / 39 62 00
sales@ie.ebmpapst.com
Fax +32 / 16 / 39 62 20 Finland
www.ebmpapst.ie
info@vibobenelux.com ebm-papst Oy
www.vibobenelux.com Puistotie 1 Italy
FIN-02760 Espoo ebm-papst Srl
Bulgaria

ESM
Phone +358 / 9 / 88 70 22 0 Via Cornaggia 108
ebm-papst Romania S.R.L.
Fax +358 / 9 / 88 70 22 13 I-22076 Mozzate (Co)
Str. Tirnavei Nr. 20
mailbox@ebmpapst.fi Phone +39 / 03 31 / 83 62 01
RO-500327 Brasov
www.ebmpapst.fi Fax +39 / 03 31 / 82 15 10
Phone +40 / 268 / 312 805
info@it.ebmpapst.com
Fax +40 / 268 / 312 805 France
EC-SYSTEMS
www.ebmpapst.it
dudasludovic@xnet.ro ebm-papst SARL
ZI Nord - rue A. Mohler Macedonia
Croatia
BP 62 ebm-papst Industries Kft.
ebm-papst Industries Kft.
F-67212 Obernai-Cedex Mátyás u. 1/A
Mátyás u. 1/A
Phone +33 / 820 326 266 H-2220 Vecsés
H-2220 Vecsés
Fax +33 / 3 / 88 67 38 83 Phone +36 / 29 / 55 01 90
Phone +36 / 29 / 55 01 90
info@ebmpapst.fr Fax +36 / 29 / 55 01 94
Accessories

Fax +36 / 29 / 55 01 94
www.ebmpapst.fr office@hu.ebmpapst.com
office@hu.ebmpapst.com
www.ebmpapst.hu
www.ebmpapst.hu Greece
Helcoma Netherlands
Cyprus
Th. Rotas & Co OE VIBO Benelux B. V.
MATERO LTD
Davaki 65 Engelseweg 127
37, St. Kyriakides Avenue
GR-17672 Kallithea-Attiki Postbus 230
Technology

P.O. Box 51744


Phone +30 / 210 / 951 37 05 NL-5705 AC Helmond
CY-3080 Limassol
Fax +30 / 210 / 951 34 90 Phone +31 / 4 92 / 50 29 00
Phone +357 / 25 / 87 00 30
contact@helcoma.gr Fax +31 / 4 92 / 50 29 50
Fax +357 / 25 / 38 13 66
www.helcoma.gr verkoop@vibobenelux.com
matero@cytanet.com.cy
www.vibobenelux.com
www.matero.com.cy
Contacts

431
fan agent

compact fan agent


Distributors, agencies and subsidiaries
motor specialist

motor agent

Norway ebm-papst Rus GmbH Switzerland


ebm-papst AS Nizhegorodskaya 32, str. 15 office 420 ebm-papst AG
P.B. 173 Holmlia RU-109029 Moskau Rütisbergstraße 1
N-1203 Oslo Phone +7 / 495 / 671 53 93 CH-8156 Oberhasli
Phone +47 / 22 / 76 33 40 Fax +7 / 495 / 671 53 95 Phone +41 / 44 / 732 20 70
Fax +47 / 22 / 61 91 73 info@ebmpapst.ru Fax +41 / 44 / 732 20 77
mailbox@ziehl-ebm.no www.ebmpapst.ru verkauf@ebmpapst.ch
www.ziehl-ebm.no www.ebmpapst.ch
ebm-papst Rus
Poland Saint-Petersburg´s Filial Turkey
ebm-papst Polska Sp. z o.o. Zastavskaya 7 Akantel Elektronik San. Tic. LTD. Sti.
ul. Annopol 4A RU-196084 Sankt-Petersburg Atatürk Organize Sanayi
PL-03236Warszawa Phone +7 / 812 / 449 96 07 Bölgesi 10007 SK. No.:6
Phone +48 / 22 / 675 78 19 Fax +7 / 812 / 449 96 07 TR-35620 Cigli-Izmir
Fax +48 / 22 / 676 95 87 spb@ru.ebmpapst.com Phone +90 / 2 32 / 32 82 090 -91
office@ebmpapst.pl Fax +90 / 2 32 / 32 80 270
Serbia & Montenegro
www.ebmpapst.pl akantel@akantel.com.tr
ebm-papst Industries Kft.
www.akantel.com.tr
Portugal Mátyás u. 1/A
ebm-papst (Portugal), Lda H-2220 Vecsés Ukraine
Av. Marechal Gomes da Costa, 35 e Phone +36 / 29 / 55 01 90 ebm-papst Ukraine LLC
Rua Conselheiro Emidio Navarro Fax +36 / 29 / 55 01 94 Lepse Boulevard, 4, Building 47
P-1800-255 Lisboa office@hu.ebmpapst.com UA-03067 Kiev
Phone +351 / 21 / 839 48 80 www.ebmpapst.hu Phone +38 / 044 / 206 30 91
Fax +351 / 21 / 839 47 59 Fax +38 / 044 / 206 30 91
Spain
info@pt.ebmpapst.com mail@ebmpapst.ua
ebm-papst Ibérica S.L.
www.ebmpapst.ua
Romania Avda. del Sistema Solar, 29
ebm-papst Romania S.R.L. E-28830 San Fernando de Henares (Madrid) United Kingdom
Str. Tirnavei Nr. 20 Phone +34 / 91 / 678 08 94 ebm-papst UK Ltd.
RO-500327 Brasov Fax +34 / 91 / 678 15 30 Chelmsford Business Park
Phone +40 / 268 / 312 805 ventas@ebmpapst.es GB-Chelmsford Essex CM2 5EZ
Fax +40 / 268 / 312 805 Phone +44 / 12 45 / 46 85 55
Sweden
dudasludovic@xnet.ro Fax +44 / 12 45 / 46 63 36
Ziehl-ebm AB
sales@uk.ebmpapst.com
Russia Äggelundavägen 2
www.ebmpapst.co.uk
ebm-papst Ural GmbH S-17562 Järfälla
Rosa Luxembourg Strasse 59 Phone +46 / 8 / 761 94 00 ebm-papst Automotive & Drives (UK) Ltd.
RU-620026 Jekaterinburg Fax +46 / 8 / 36 23 06 The Smithy
Phone +7 / 343 / 378 31 75 info@ebmpapst.se Fidlers Lane, East Ilsley
Fax +7 / 343 / 378 31 89 www.ebmpapst.se GB-Berkshire RG20 7LG
Konstantin.Molokov@ru.ebmpapst.com Phone +44 / 87 07 / 66 51 70
www.ebmpapst.ur.ru Fax +44 / 87 07 / 66 51 80
A&Dsales@uk.ebmpapst.com
www.ebmpapst-ad.com

432
information
General
AC axial fans
AC axial
S series
AC axial
K series
America USA Africa
ebm-papst Inc.
Argentinia South Africa

AC axial
A series
P.O. Box 4009
ebm-papst de Argentina S.A. ebm-papst South Africa (Pty) Ltd.
100 Hyde Road
Hernandarias 148 Lomas del Mirador P.O. Box 3124
USA-Farmington, CT 06034
Pcia. de Buenos Aires (1752) 1119 Yacht Avenue
Phone +1 / 860 / 674 15 15
Phone +54 / 11 46 57 61 35 ZA-2040 Honeydew
Fax +1 / 860 / 674 85 36
Fax +54 / 11 46 57 20 92 Phone +27 / 11 / 794 34 34
sales@us.ebmpapst.com

EC axial fans
ventas@ar.ebmpapst.com Fax +27 / 11 / 794 50 20
www.ebmpapst.us
info@za.ebmpapst.com
Brasil
ebm-papst Automotive & Drives, Inc. www.ebmpapst.co.za
ebm-papst Motores Ventiladores Ltda.
3200 Greenfield, Suite 255
Rua Francisco D´Amico, 155
USA-Dearborn, MI 48120
Bairro Pirajussara
Phone +1 / 313 / 406 80 80
BR-06785-290 Taboão da Serra-SP
Fax +1 / 313 / 406 80 81
Phone +55 /11 / 41 38 50 90
automotive@us.ebmpapst.com

EC axial
S series
Fax +55 /11 / 41 38 50 86
www.ebmpapst-automotive.us
vendas@br.ebmpapst.com
www.ebmpapst.com.br
Canada
ebm-papst Canada Inc.
1800 Ironstone Manor, Unit 2

Q-motor
CDN-Pickering, Ontario, L1W3J9
Phone +1 / 905 / 420 / 35 33
Fax +1 / 905 / 420 / 37 72
sales@ca.ebmpapst.com
www.ebmpapst.ca
Mexico
ebm Industrial S.de R.L. de C.V.

ESM
Paseo de Tamarindos 400-A-5to Piso
Col. Bosques de las Lomas
MEX-Mexico 05120, D.F.
Phone +52 / 55 / 50 91 44 44
Fax +52 / 55 / 50 91 44 43

EC-SYSTEMS
sales@mx.ebmpapst.com
www.ebmpapst.com.mx

Accessories
Technology
Contacts
433
fan agent

compact fan agent


Distributors, agencies and subsidiaries
motor specialist

motor agent

Asia Japan Thailand Australia


ebm-papst Industries Japan K.K. ebm-papst Thailand Co. Ltd.
China Australia
12 Floor, Benex S-3 Bldg. Representative Office
ebm-papst Ventilator (Shanghai) Co., Ltd. ebm-papst Australia Pty Ltd.
3-20-8 Shinyokohama, Kohoku-ku 99/349 Chaeng Wattana Road, Laksi
No. 418, Huajing Road 2 Silverton Close
J-222-0033 Yokohama Bangkok 10210, Thailand
WaiGaoQiao Free Trade Zone AUS-Laverton North, Victoria, 3026
Phone +81 / 45 / 470 / 57 51 Phone +66 / 2 / 576 / 15 24-5
No. 2001, Yang Gao (N) Road Phone +61 / 3 / 83 25 64 00
Fax +81 / 45 / 470 / 57 52 Fax +66 / 2 / 576 / 15 42
VRC-200131 Shanghai, P.R. of China Fax +61 / 3 / 83 25 64 64
info@jp.ebmpapst.com salesdept@th.ebmpapst.com
Phone +86 / 21 / 50 46 01 83 sales@ebmpapst.com.au
www.ebmpapst.jp
Fax +86 / 21 / 50 46 11 19 United Arab Emirates www.ebmpapst.com.au
sales@cn.ebmpapst.com Korea ebm-papst Middle East FZE
New Zealand
ebm-papst Korea Co. Ltd. PO Box 17755
Hong Kong ebm-papst Australia Pty Ltd.
6F, Trutec Bldg. Jebel Ali Free Zone / FZS1 / AP05
ebm-papst Ventilator (Shanghai) Co., Ltd. 102 Henderson Valley Road
B 6-2, Digital Media City (DMC) UAE-Dubai
Hong Kong Representative Office NZ-Henderson, Auckland 1230
Sangam-Dong, Mapo-Gu Phone +971 / 4 / 886 08 26
Unit Nos. 13, 9/F, Technology Park Phone +64 / 9 / 837 18 84
ROK-Seoul 121-270 Fax +971 / 4 / 886 08 27
18 On Lai Street, Sha Tin, N.T. Fax +64 / 9 / 837 18 99
Phone +82 / 2 / 36 62 / 13 24 info@ae.ebmpapst.com
HK-Hong Kong P.R. of China sales@ebmpapst.com.au
Fax +82 / 2 / 36 62 / 13 26
Phone +852 / 21 45 / 86 78 www.ebmpapst.com.au
info@kr.ebmpapst.com
Fax +852 / 21 45 / 76 78
www.ebmpapst.co.kr
chenghong@cn.ebmpapst.com
Malaysia
India
ebm-papst Malaysia
ebm NADI International Pvt Ltd.
Representative Office
26/3, G.N.T. Road, Erukkencherry
Block F1, 9A-4, Jalan PJU 1/42
IND-Chennai-600118
Dataran Prima
Phone +91 / 44 / 25 37 25 56
MAL-47301 Petaling Jaya
Fax +91 / 44 / 25 37 11 49
Phone +60 / 3 / 78 06 54 40
ebmnadi@md2.vsnl.net.in
Fax +60 / 3 / 78 06 54 41
www.ebmnadi.com
john.bulder@my.ebmpapst.com
Indonesia
Singapore
ebm-papst Indonesia
ebm-papst SEA Pte. Ltd.
Representative Office
23 Ubi Road 4, #05-00
Jalan Puri Kencana, Blok K7/3T
Olympia Industrial Building
RI-Jakarta 11610
SGP-Singapore 408620
Phone +62 / 21 / 582 / 31 18
Phone +65 / 68 42 84 38
Fax +62 / 21 / 582 / 31 17
Fax +65 / 68 42 84 39
sonny.sanjaya@id.ebmpapst.com
salesdept@sg.ebmpapst.com
Israel
Taiwan
Polak Bros. Import Agencies Ltd.
ETECO Engineering & Trading Corp.
9 Hamefalsim Street
10F-I, No. 92, Teh-Wei Str.
IL-Kiryat Arie, Petach-Tikva 49514
RC-Tsow-Inn District, Kaohsiung
Phone +972 / 3 / 910 03 00
Phone +886 / 7 / 557 42 68
Fax +972 / 3 / 579 66 79
Fax +886 / 7 / 557 27 88
polak@polak.co.il
eteco@ms22.hinet.net

434 435
fan agent

compact fan agent


Distributors, agencies and subsidiaries
motor specialist

motor agent

Asia Japan Thailand Australia


ebm-papst Industries Japan K.K. ebm-papst Thailand Co. Ltd.
China Australia
12 Floor, Benex S-3 Bldg. Representative Office
ebm-papst Ventilator (Shanghai) Co., Ltd. ebm-papst Australia Pty Ltd.
3-20-8 Shinyokohama, Kohoku-ku 99/349 Chaeng Wattana Road, Laksi
No. 418, Huajing Road 2 Silverton Close
J-222-0033 Yokohama Bangkok 10210, Thailand
WaiGaoQiao Free Trade Zone AUS-Laverton North, Victoria, 3026
Phone +81 / 45 / 470 / 57 51 Phone +66 / 2 / 576 / 15 24-5
No. 2001, Yang Gao (N) Road Phone +61 / 3 / 83 25 64 00
Fax +81 / 45 / 470 / 57 52 Fax +66 / 2 / 576 / 15 42
VRC-200131 Shanghai, P.R. of China Fax +61 / 3 / 83 25 64 64
info@jp.ebmpapst.com salesdept@th.ebmpapst.com
Phone +86 / 21 / 50 46 01 83 sales@ebmpapst.com.au
www.ebmpapst.jp
Fax +86 / 21 / 50 46 11 19 United Arab Emirates www.ebmpapst.com.au
sales@cn.ebmpapst.com Korea ebm-papst Middle East FZE
New Zealand
ebm-papst Korea Co. Ltd. PO Box 17755
Hong Kong ebm-papst Australia Pty Ltd.
6F, Trutec Bldg. Jebel Ali Free Zone / FZS1 / AP05
ebm-papst Ventilator (Shanghai) Co., Ltd. 102 Henderson Valley Road
B 6-2, Digital Media City (DMC) UAE-Dubai
Hong Kong Representative Office NZ-Henderson, Auckland 1230
Sangam-Dong, Mapo-Gu Phone +971 / 4 / 886 08 26
Unit Nos. 13, 9/F, Technology Park Phone +64 / 9 / 837 18 84
ROK-Seoul 121-270 Fax +971 / 4 / 886 08 27
18 On Lai Street, Sha Tin, N.T. Fax +64 / 9 / 837 18 99
Phone +82 / 2 / 36 62 / 13 24 info@ae.ebmpapst.com
HK-Hong Kong P.R. of China sales@ebmpapst.com.au
Fax +82 / 2 / 36 62 / 13 26
Phone +852 / 21 45 / 86 78 www.ebmpapst.com.au
info@kr.ebmpapst.com
Fax +852 / 21 45 / 76 78
www.ebmpapst.co.kr
chenghong@cn.ebmpapst.com
Malaysia
India
ebm-papst Malaysia
ebm NADI International Pvt Ltd.
Representative Office
26/3, G.N.T. Road, Erukkencherry
Block F1, 9A-4, Jalan PJU 1/42
IND-Chennai-600118
Dataran Prima
Phone +91 / 44 / 25 37 25 56
MAL-47301 Petaling Jaya
Fax +91 / 44 / 25 37 11 49
Phone +60 / 3 / 78 06 54 40
ebmnadi@md2.vsnl.net.in
Fax +60 / 3 / 78 06 54 41
www.ebmnadi.com
john.bulder@my.ebmpapst.com
Indonesia
Singapore
ebm-papst Indonesia
ebm-papst SEA Pte. Ltd.
Representative Office
23 Ubi Road 4, #05-00
Jalan Puri Kencana, Blok K7/3T
Olympia Industrial Building
RI-Jakarta 11610
SGP-Singapore 408620
Phone +62 / 21 / 582 / 31 18
Phone +65 / 68 42 84 38
Fax +62 / 21 / 582 / 31 17
Fax +65 / 68 42 84 39
sonny.sanjaya@id.ebmpapst.com
salesdept@sg.ebmpapst.com
Israel
Taiwan
Polak Bros. Import Agencies Ltd.
ETECO Engineering & Trading Corp.
9 Hamefalsim Street
10F-I, No. 92, Teh-Wei Str.
IL-Kiryat Arie, Petach-Tikva 49514
RC-Tsow-Inn District, Kaohsiung
Phone +972 / 3 / 910 03 00
Phone +886 / 7 / 557 42 68
Fax +972 / 3 / 579 66 79
Fax +886 / 7 / 557 27 88
polak@polak.co.il
eteco@ms22.hinet.net

434 435
37779-7-8811 • KO-08/07-10,8’
Printed in Germany
version 07
Axial fans

version 07
Axial fans
ebm-papst ebm-papst ebm-papst
Mulfingen GmbH & Co. KG St.Georgen GmbH & Co. KG Landshut GmbH

Bachmühle 2 Hermann-Papst-Straße 1 Hofmark-Aich-Straße 25


D-74673 Mulfingen D-78112 St.Georgen D-84030 Landshut
Phone +49 (0) 7938 / 81-0 Phone +49 (0) 7724 / 81-0 Phone +49 (0) 871/ 707-0