Rev. 6-12-02
CCEZ+ manual.p65
Table of Contents
Definitions i
Warranty 1
Introduction 2
Drivecon Corporation
820 Lakeside Drive
Gurnee, IL 60031 USA
Definitions:
Qualified Person:
For the purpose of this instruction manual and product labels, a QUALIFIED PERSON is one
who is familiar with the installation, construction, operation and maintenance of the equipment,
and the hazards involved. In addition, the person must have the following qualifications:
1. Is trained and authorized to energize, de-energize, clear, ground and tag circuits and
equipment in accordance with established safety practices.
2. Is trained in the proper care and use of protective equipment such as rubber gloves,
hard hat, safety glasses or face shields, flash clothing, etc., in accordance with
established safety practices.
3. Is trained in rendering first aid.
DANGER: For the purpose of this manual and product labels, DANGER indicates loss of
life, severe personal injury or substantial property damage WILL result if proper
precautions are not taken.
WARNING: For the purpose of this manual and product labels, WARNING indicates loss of
life, severe personal injury or substantial property damage CAN result if proper
precautions are not taken.
CAUTION: For the purpose of this manual and product labels, CAUTION indicates minor
personal injury or property damage can result if precautions are not taken.
NOTE: For the purpose of this manual and product labels, NOTES merely call attention
to information that is especially significant in understanding and operating the
drive.
i
Thank You!
We at Drivecon and affiliated dealer appreciate your purchase of this 'CCez+' inverter or,
adjustable frequency drive. When properly installed, operated and maintained, the inverter will
provide a lifetime of reliable operation. It is mandatory that the person who operates, inspects,
and maintains this equipment thoroughly read and understand this manual.
This instruction manual has been designed to serve as a self-supporting guide for the proper
installation, operation, and maintenance of the inverter adjustable frequency drive. If you
require additional assistance please feel free to contact either your local supplier or Drivecon
at (847) 855-9150.
DANGER!
Hazardous voltage within can cause serious injury or death. Operating drive from keypad may
disable safety circuits and result in danger or injury. Only qualified personnel should work on this
equipment after familiarization with its operation. Turn OFF and lock out power at main panel.
Allow capacitors to bleed off prior to servicing.
DANGER: DO NOT touch any circuit components while AC main power is on or immediately
after the main AC power is disconnected from the unit. Please wait 3 minutes before perform-
ing any service work to inverter.
DANGER: DO NOT make any contact with the circuit before inverter is disconnected from the
AC line and discharged. Failure to adhere t ent. The CCez is designed for operation of
traverse motions or hoist motions with properly operating mechanical load brakes. Consult
Drivecon for operating hoists without mechanical load brakes. The CCez is suited for CMAA
class A-D use only.
WARRANTY:
Drivecon warrants that all products manufactured by it to be free from defects in material and/
or workmanship under proper and normal use by the initial user. This warranty shall expire
twenty-four (24) months following the date of shipment of such product to the purchaser.
Drivecon is the sole determinant of all claims under warranty and no credit will be allowed for
damaged equipment resulting from improper installation or unauthorized repairs or alterations.
During this warranty period, Drivecon will repair or replace, FOB its plant, any parts reported to
and found to be defective by its inspection. Drivecon will not assume any expenses or liability
for any work done on its equipment outside of Drivecon plant without its written consent and
such unauthorized work will automatically void Drivecon's warranty. Equipment purchased
from others and resold by Drivecon, will carry the warranty of the manufacturer. This warranty
is in lieu of all other warranties expressed or implied including warranty of merchantability of
fitness for a particular use. Also Drivecon specifically does not warrant for any consequential
damages whatsoever. Drivecon does not assume or authorize any other person to assume for
it any obligation in connection with the sale of its products, except as herin expressly stated.
1
Introduction
General
CCez+ series is a high performance 460V crane duty inverter which incorporates a high effi-
ciency Pulse Width Modulated (PWM) design. The output closely approximates a sinusoidal
current waveform to allow variable speed control of any conventional 3 phase squirrel cage
induction motor. Please consult Drivecon if any question exists regarding the motor planned to
be connected to the inverter.
Receiving
This unit has been put through strict Q.C. tests at the factory prior to shipment.
Please compare the description of the product found on the name plate with your
purchase order.
Inspect for transport damage (serious damage of carton may lead to unit damage)
If the specifications (current and voltage) on the front cover name plate matches your
application requirements.
Note: If any part of the inverter is damaged or lost, please notify the carrier and
Drivecon immediately.
2
1.0 CCez+ Frequency converter for travel
;
;
The frequency converter changes the speed and direction of rotation of the travelling motor
according to the commands given by the operator.
The frequency converter has a green LED (3) indicating its operating status and a red LED (2)
to indicate a malfunction. When the operating status LED (3) is lit, the frequency converter is
operating normally. When the operating status LED (3) is flashing, a malfunction has occured
but it has been reset, operation is possible. When the malfunction LED (2) is lit, a malfunction
has occurred that prevents operation of the inverter.
The settings for the frequency converter have been pre-set at the factory with the parameter
switches (4). All control signal connections to the frequency converter are made via connector
X1 (1). Power cabling connections to the frequency converter are made via connector X2 (1).
The frequency converter contains live parts at voltages that could cause death by electric
shock. Wait at least (3) three minutes after disconnecting the electricity supply before carrying
out any service procedures on the frequency converter.
Test the correct operation of the frequency converter by driving a motor via the use of the
operator controls.
Check the LED (3) for operational status and the LED (2) for any malfunction.
If the malfunction signal lamp (2) of the frequency converter is lit, contact Drivecon at 847-955-
9150, 800-374-8266 or on the web at www.drivecon.com or your authorized dealer.
3
1.2 Specifications:
4
2.0 Installation of the CCez+
Location
Proper location of the inverter is imperative to achieve specified performance & normal
operation life expectancy. The inverter should always be installed in areas where the following
conditions exist:
Select a mounting location with adequate ventilation and clearance as shown in drawing be-
low. Insure location selected to include the following:
NOTE: Inverter life expectancy will be shortened if these points are not followed.
Clearances
For cooling and maintenance purpose, sufficient clearance (as shown in figure 2.0) around
inverter is necessary to keep effective ventilation. Inverter must be installed with heat sink fins
oriented vertically.
5
2.0 Installation of the CCez+
DANGER! There are high voltages inside the inverter (including the programming
switches). Wait for at least three minutes after the supply voltage has been switched off
before performing any service activities.
'ULYHFRQ
0 2 7 2 5 ' 5 , 9 ( 6 $ 1 ' & 2 1 7 5 2 / 6
6
2.2 Connections
Control signals are connected to terminal block X1 located on top of inverter (dark gray) as
follows: Use 16 AWG MTW type copper wire for all connections to X1.
Note: Read terminal numbers from left to right looking down at top of inverter. See Fig. 2.1.
Note:
1) Do not connect any inductive loads in parallel with DI-DI5. Back emf surge will destroy
input circuit.
2) Install R-C suppressor across any inductive loads.
3) Do not exceed rated supply voltage of input supply.
1XPEHU 1DPH 'HVFULSWLRQ
', 'ULYHFRPPDQG'LUHFWLRQRU9
+]
', 'ULYHFRPPDQG'LUHFWLRQRU9
+]
', 'LJLWDOLQSXWRU9+]
', 'LJLWDOLQSXWRU9+]
', 'LJLWDOLQSXWRU9+]
1 &RQWUROYROWDJHQHXWUDO
5 5HOD\RXWSXW
5 5HOD\RXWSXW
(PSW\
Power cabling is connected to terminal block X2 located on botton of inverter (green) as fol-
lows. Adhere to following Cautions. Note: Read terminal numbers from left to right looking at
front of inverter. See drawing Fig. 2.1.
Notes:
1) Crane power supply conductor rail must have double collectors.
2) Inverter and motor must be grounded.
3) Motor must be suited for inverter use. If not, an OLF motor protection filter must be
added between the motor and inverter.
4) If the line supply transformer is greater than 50KVA Drivecon recommends the addition
of a 3 phase line reactor on the input side.
5) Use 14 AWG MTW type copper wire for all connections to X2.
6) Install proper line fuses per NEC code for short circuit protection.
7) Add separate motor protection overload device if motor thermostats are not provided.
8) Wire in accordance with all local regulations and NEC codes.
1XPEHU 1DPH 'HVFULSWLRQ
/ 0DLQVSKDVH9+]
/ 0DLQVSKDVH9+]
/ 0DLQVSKDVH9+]
87 0RWRUSKDVH
97 0RWRUSKDVH
:7 0RWRUSKDVH
5 %UDNLQJUHVLVWRUSRVLWLYH
5 %UDNLQJUHVLVWRUQHJDWLYH
3( 3URWHFWLYHHDUWK
WARNING!!! Inverter must not be connected to following networks:
- isolated ground system (Delta or open delta supply systems)
- high-impedance grounded system
- phase grounded/grounded leg system. (Grounded B phase systems)
Note: An isolation transformer may be required if the user's power supply is any
one of the above systems. 7
2.2 Wiring diagram
Fig. 2.2
8
2.3 Normal operation
The inverter goes into the ready-to-run state within one second after the power supply is con-
nected. During operation the inverter follows the operators speed command according to the
set acceleration/deceleration ramp. During operation the brake relay (R01 and R02) is kept
closed. When drive command is switched off the inverter decelerates to zero according to the
set ramp and opens the brake relay.
Note: It is required to wire holding brake through brake contactor operated by relay terminals
R01 and R02.
The programming of the inverter is performed by dip-switches. The state of each switch is
either OFF (0) or ON (1). It is possible to set he following parameters by the switches S1-S6.
S1 = Maximum speed
S2 = Minimimum speed
S3 = Acceleration / deceleration time
S4 = Motor frequency and IR-compensation
S5 = Motor current, fast deceleration, stopping method
S6 = Control mode, slowdown limit speed, speed # 2, speed # 3
Turn to section 3 for additional details on programming the inverter via dip switches.
Note: The inverter is normally shipped with all dip switches in the off mode. The in-
verter will not operate in this mode until the switches are programmed accordingly.
9
3.0 Programming of the application parameters
Note: Check that the wiring and the desired performance of the
machinery is suitable for the selected application parameters.
PRWRU PRWRU
0D[IUHT+] 0LQIUHT+]
0D[IUHT+] 0LQIUHT+]
0D[IUHT+] 0LQIUHT+]
6ZLWFK6
5DPSWLPH
VHF
It is possible to reduce the deceleration ramp time by 30% if necessary. The fast deceleration
ramp is activated by switching S5-3 ON (1).
12
3.2 Stopping method
The motor can be stopped either by dynamic braking (by a ramp) or by mechanical brake.
When stopping by mechanical brake is selected and drive command is switched off the in-
verter immediately cuts off the motor current and opens the run status relay contact (R01 and
R02). The stopping method is selected by switch S5-4 as follows:
$FFHO $FFHOHUDWLRQFRPPDQG
6 6ORZGRZQOLPLWIRUZDUG
6 6WRSOLPLWIRUZDUG
63 6SHHG
+63 +LJKVSHHG
6 'ULYHFRPPDQGUHYHUVH
+2/' +ROGVSHHGFRPPDQG
6 6ORZGRZQOLPLWUHYHUVH
6 6WRSOLPLWUHYHUVH
63 6SHHG
13
3.4 Slow down travel limits
Fig. 3.4
Slowdown frequency is activated in 2 and 3 step infinitely variable control modes when the
slowdown limit circuit is opened. In 2 step infinitely variable there are separate inputs for both
limit switch, therefore it is possible to drive high speed in the slowdown area in the safe direc-
tion. In 3 step infinitely variable there is only one input and therefore the speed is limited in
both directions in the slowdown area. There are two alternatives for the level of slowdown
speed which are selected by switch S6-3 as follows:
S6-3 = 0 Slowdown speed is 20% of the maximum speed (set by switch S1)
S6-3 = 1 Slowdown speed is 35% of the maximum speed (set by switch S1)
Fig. 3.6
14
4.0 Programming of the motor parameters
The motor parameters are set by switches S4 and S5 according to the following tables. Set-
tings for other motors can be defined when motor nominal frequency, voltage, current and the
torque boost are known. See section 3.1 for more details.
Motor nominal voltage and frequency are selected by switches S4-1 and S4-2 according to the
following table:
By the torque boost compensation the effect of the stator resistance at low frequencies is
compensated by increasing the V/f-ratio. Typically the necessary amount of compensation
(added voltage) is higher for small motors. The torque boost compensation is set by switches
S4-3 and S4-4. Estimation of the correct setting of torque boost compensation is made by
calculating the IR-rate of the motor.
Fig. 4.1
Note: Torque boost rate will vary from application to application. It is suggested to set the
torque boost so that the motor rotates at low speed under worst load conditions.
Note: Do not turn torque boost higher than actually required since motor heat rise will in-
crease.
15
Calculation of IR-rate: IR-rate= INOM*RS*p*n
Settings:
,5UDWH 6HWWLQJRI6
6 6
6 6
6 6
6 6
For conical brake motors it is recommended to set the torque boost compensation one step
higher than the IR-rate indicates. Reliable operation of the brake must be verified during start-
up.
Example of motor current setting: there are two 1.5A motors. Setting is S5-1=0 and S5-2=1.
16
5.0 Description of control modes
5.1 2 preset speed control
Fig. 5.1
Fig. 5.2
S1 means "drive forward"
S2 means "drive reverse"
Accel means "accelerate"
When starting, S1 and S2 mean "accelerate to minimum speed"
When S1 and S2 are not active, the inverter decelerates to zero or stops
according to S5-4.
During running of S1 and S2 means "hold speed"
At maximum speed Accel will "hold speed", never allowing acceleration beyond
maximum speed.
17
5.3 3 step infinitely variable control
Fig. 5.3
S1 means "drive minimum speed forward"
S2 means "drive minimum speed reverse"
Accel means "accelerate"
HOLD means "hold speed"
When starting, S1 and S2 mean "accelerate to minimum speed"
When S1 and S2 are not active, the inverter decelerates to zero or stops according to S5-4.
During running of S1 and S2 means "hold speed"
At maximum speed Accel will "hold speed", never allowing acceleration beyond
maximum speed.
5.4 4 preset speed control
Fig. 5.4
S1 means "drive minimum speed forward"
S2 means "drive minimum speed reverse"
SP2 means "drive speed 2"
SP3 means "drive speed 3"
HSP means "drive maximum speed"
When S1 and S2 are not active, the inverter decelerates to zero or stops according to S5-4.
The "highest" active input sets the speed reference (i.e. if HSP is active SP2 and SP3 are
ignored. If SP3 is active, SP2 is ignored).
18
6 Fault codes, troubleshooting
CAUTION! There are high voltages inside the inverter (including the programming
switches). Wait for at least three minutes after the supply voltage has been switched off
before any service actions.
When the inverter detects a fault situation it stops running and starts signalling the fault code
by blinking the indication leds (green and red). The blinking of the code is carried on until a
new fault occurs or until power is switched off. The fault codes are explained in the table be-
low.
)DXOWFRGHFRORU )DXOW3RVVLEOHFDXVH&KHFNLQJV
2YHUYROWDJH0DLQVYROWDJHLVWRRKLJKRUGHFHOHUDWLRQUDPSWLPHLV
*UHHQ WRRVKRUW&KHFNWKHYROWDJHRIDOOVXSSO\SKDVHVDWWKHWHUPLQDO;,I
WKH\DUHRNVHWDORQJHUUDPSE\VZLWFK6DQG6
6WDOOVXSHUYLVLRQRYHUFXUUHQW%UDNHGRHVQRWRSHQSURSHUO\RUWKHUH
*UHHQ LVDQREVWDFNOHRQWKHWUDFN&KHFNDOVRWKHPRWRUGHSHQGHQW
SDUDPHWHUVVHHVHFWLRQ
'HFHOHUDWLRQUDPSVXSHUYLVLRQ'HFHOHUDWLRQUDPSKDVQRWEHHQ
*UHHQ IROORZHG,IWKHIDXOWRFFXUVDJDLQVHWORQJHUUDPSWLPHE\VZLWFK6
&KHFNDOVRWKHVHWWLQJRIWKHPRWRUQRPLQDOFXUUHQWVZLWFK6
0RWRURYHUWHPSHUDWXUH&KHFNWKHW\SHDQGWKHORDGLQJRIWKHPRWRU
*UHHQ ,IWKHUHLVQRVHQVRULQWKHPRWRUWKHLQYHUWHUWHUPLQDOV;PXVW
EHVKRUWFLUFXLWHG
,QYHUWHURYHUWHPSHUDWXUH0RWRUFXUUHQWLVWRRKLJKEHDULQJSUREOHP
DPELHQWWHPSHUDWXUHLVWRRKLJK
8QGHUYROWDJH&KHFNWKHYROWDJHRIDOOVXSSO\SKDVHVDWWKHWHUPLQDO
*UHHQ
;
6KRUWFLUFXLW6ZLWFKWKHSRZHURII&KHFNWKHLQVXODWLRQRIWKHPRWRU
5HG
FDEOHVDQGWKHPRWRUZLQGLQJV
0LFURSURVHVVRUIDXOW6ZLWFKWKHSRZHURIIIRUVHFRQGV7KHQ
5HG
SRZHUXSWKHLQYHUWHU
The latest active fault is removed from the memory always when power is switched off.