Sunteți pe pagina 1din 2

157

DEEP SEA ELECTRONICS PLC RELAY


EXPANSION
053-040
DESCRIPTION Issue 5
C US JM 23/08/07
The 157 is an output relay Using this modular approach and
expansion module for DSE utilising the benefits of single wire
control modules. It can be host connection, enhanced
configured to provide volt-free specifications can be achieved with
contacts, which allow the OEM to minimum modification to standard
meet increasingly complex panels.
specifications in the industry by
adding to the capacity of the Traditional methods would have
controllers. required the use of a PLC based SPECIFI C ATIO N
system or extensive additional DC SUPPLY :
The module comprises a single relay logic with all its added The 157 is powered from the plant
‘DIN’ rail mounted module with an complexity. battery or from a low voltage supply
interconnecting FCC 68 cable. between 8V to 35V DC. It is able to
This enables rapid fixing into a For a complete list of all the survive 0V for 50ms during cranking,
panel and can be situated up to possible control sources for the providing supply was at least 10V
50 metres away from the host 157 relay module, please refer to before dropout and supply recovers to
module. the appropriate configuration 5V. This is achieved without the need
Software manual. for internal batteries.
The relay expansion features MAX. OPERATING CURRENT:
eight 5A DC rated, voltage-free 120mA @ 12V, 70mA @ 24V.
relay contacts which can be CONFIGUR ATIO N
configured to be normally de- MAX. STANDBY CURRENT:
The module will automatically
energised, close on command, or 25mA @ 12V, 18mA @ 24V
respond to signals from a correctly
normally energised, open on
configured module, which must be AUXILIARY RELAY CONTACTS:
command.
configured via the appropriate 5A DC rated voltage free.
interface and a PC. The
The relay expansion is an
Expansion relays appear in the DIMENSIONS:
extension of the modules’ output
Output configuration menu. For 160mm x 77mm x 72mm
capabilities. Simply connect the (6.3” x 3” x 2.8”)
more information on configuration
relay board to a correctly DIN Rail mounted housing.
and output states refer to the
configured module expansion
appropriate Software Manual.
socket. OPERATING TEMPERATURE
RANGE:
o o
Supported controllers are -15 C to +55 C
configured to control the NOTE:- The 157 Relay
expansion relays. The 157 relay SELECTOR SWITCHES:
Expansion Module must only be
expansion will operate with the Test - Operates all relays to test
connected to module types 520, 521,
operation.
following controllers: 530, 540, 541, 550, 555, 556, 560,
Unused - No Function.
520, 521, 530, 540, 541, 550, 5210, 5220, 5310, 5320, 5510, 5520,
Enable Lamp Test - Relays will
555, 556, 560, 5210, 5220, 5310, 5560 or future compatible modules.
energise on receipt of a Lamp test
5320, 5510, 5520, 5560. signal from compatible Host module.
(NB. The 157 relay expansion module will A/B Select - Determines whether the
NOT operate with module types 511, 512, NOTE:- Input expansion modules 157 responds to signals for Expansion
5110, 5120 or 509) are available for all modules : A or B relays - (See Note)
540 / 541 protection expansion
On the 55x, 53xx and 55xx annuciators can be used with all INDICATIONS:
modules two 157 relay boards DSE control modules to increase Power On LED
can be used to give 16 the number of basic digital inputs. ‘Link Lost’ (to controller) LED Flashing
independent relay outputs. This 8 Relay active LED’s
P130 input expansion module is
is achieved by identifying one of compatible with module types
the 157 modules as module ‘A’ 5310, 5310, 5510, 5520 and 5560
and the other as module ‘B’ by and provides an additional two
means of a small selector switch analogue inputs and eight In line with our policy of continual improvement,
DSE reserve the right to change the
fitted to the 157. enhanced digital inputs. specification without prior notice.
C ASE DI MENSI O NS

POWER ON LED

RELAY ACTIVE LED'S

72.0mm 77.0mm

LINK LOST LED


FUNCTION
SELECTOR

160.0mm
77.0mm

Imperial
157 Relaymeasurements:
Expansion (6.3”
Unit xArrangement
3” x 2.8”)

TYPIC AL CO NNE CTIO NS

NOTE: The 157 relay status is updated a minimum of twice a second. While this makes the response of the
relays fast enough for annunciation, remote monitoring and normal system control it is not considered suitable
for use in time critical applications such as high speed breaker tripping etc. If this type of function is intended we
would recommend using the host modules own relay outputs to control such systems.

NOTE: The 157 must be used in the correct mode to function correctly. The ‘A’ mode is used to number the
157 Relays 1 through to 8. The ‘B’ mode is used to number the Relays 9 through to 16. Thus using one 157 in
‘A’ mode and one ‘B’ mode 157 give 16 independent Relays. Mode selection is via a function selector switch on
the module.
The A/B selector switch must be set to the ‘A’ position for the 157 module to operate the following modules as
these support only one expansion module and do not support ‘B’ mode: 520, 521, 530, 540, 541, 560, 5210,
5220.