Sunteți pe pagina 1din 4

3-Way Solenoid SERIES

4 For Oil-Free Instrument Air


1/4" ANPT NT8320

The NT Series, 3-way direct acting solenoid valve, is used


primarily as a Class 1E safety-related pilot operator on
larger control valves in nuclear power plants.
Qualification Report AQR 35115-3/AQR 100115

Features
• Elastomers (gaskets, o-rings, discs): resist high radiation,
high temperature degradation effects
• Designed for integration into digital controls
• DC valves have suppression diode
• Quick Disconnect Connector (QDC)*
• Field side connector supplied with up to 30 ft. leads,
with a temp rating of up to 392°F (200°C)*
• One piece solenoid/coil design for ease of maintenance
*See coil and connector order page

Construction
Valve Parts in Contact with Fluids 1
Body Brass NC
3 2
Core Tube 305 Stainless Steel
Core and Plugnut 430F Stainless Steel
NO
Core Guide (AC Model) Brass U
Springs 302 Stainless Steel
Seals and Disc Gamma +
Disc-Holder Stainless Steel

Electrical

Watt Rating and Power Consumption


Standard Coil AC
and Class
of Insulation DC Watts Watts VA Holding VA Inrush
H 14.6 10.1 25 50

Replacement Coil Base Part Number Installation


(without voltage and lead length) Solenoid can be mounted in any position without
affecting operation
DC
Without Solenoid Enclosures
Coil/Lead Type With Diode Diode AC
Standard: Watertight, Types 3, 3S, 4, & 4X
Peek Leads G432267 G434924 G431786
Silicone Leads G433397 G512230 G501520
Coil w/QDC G438046 N/A G438440
Nominal Ambient Temp. Ranges
32°F to 140°F (0°C to 60°C)
Nominal Voltages: 48, 125, or 250VDC; 120/60 or 220/50 AC.
Must be specified when ordering
Approvals
% CSA Certified.

1
SERIES
NT8320 4
Specifications
Maximum Operating Cv (Kv=m3/h)
Pipe Orifice Pressure Differential Air psi (bar) Flow Factor Watt Rating
Size Size Safe Working Pressure Cylinder
(in) in (mm) AC DC Pressure psi (bar) to Cylinder to Exhaust Base Catalog Number AC DC
Normally Closed
1/4 1/16 (1.6) 175 (12) 160 (11) 300 (21) 0.07 (0.06) 0.09 (0.08) NT[ ]8320G182[ ] 10.1 14.6
1/4 3/32 (2.4) 150 (10) 115 (8) 300 (21) 0.10 (0.09) 0.15 (0.13) NT[ ]8320G184[ ] 10.1 14.6
1/4 1/8 (3.2) 85 (6.9) 60 (4.1) 300 (21) 0.18 (0.15) 0.29 (0.25) NT[ ]8320G186[ ] 10.1 14.6
1/4 11/64 (4.4) 45 (3.1) 25 (1.7) 300 (21) 0.27 (0.23) 0.41 (0.35) NT[ ]8320G188[ ] 10.1 14.6
Normally Open
1/4 1/16 (1.6) 175 (12) 135 (9) 300 (21) 0.07 (0.06) 0.09 (0.08) NT[ ]8320G192[ ] 10.1 14.6
1/4 3/32 (2.4) 140 (10) 100 (7) 300 (21) 0.13 (0.11) 0.10 (0.09) NT[ ]8320G194[ ] 10.1 14.6
1/4 1/8 (3.2) 70 (4.8) 55 (3.8) 300 (21) 0.23 (0.20) 0.20 (0.17) NT[ ]8320G196[ ] 10.1 14.6
1/4 11/64 (4.4) 40 (2.8) 30 (2.1) 300 (21) 0.31 (0.27) 0.28 (0.24) NT[ ]8320G198[ ] 10.1 14.6
Universal Operation (Pressure at port 2 or 3 only)
1/4 1/16 (1.6) 125 (7) 75 (5.2) 300 (21) 0.07 (0.06) 0.09 (0.08) NT[ ]8320G172[ ] 10.1 14.6
1/4 3/32 (2.4) 75 (5.2) 60 (4.1) 300 (21) 0.10 (0.09) 0.10 (0.09) NT[ ]8320G174[ ] 10.1 14.6
1/4 1/8 (3.2) 35 (2.4) 25 (1.7) 300 (21) 0.17 (0.15) 0.20 (0.17) NT[ ]8320G176[ ] 10.1 14.6
1/4 11/64 (4.4) 20 (1.4) 12 (0.8) 300 (21) 0.31 (0.27) 0.28 (0.24) NT[ ]8320G178[ ] 10.1 14.6

Note: See next page for a complete catalog number example and optional features.

Dimensions: inches (mm)


Flow Diagrams

Universal
De-Energized Energized

Standard leaded version


3 3

2 1 2 1

Normally Closed
De-Energized Energized

2 1 3

Press. 3 Cyl. Press. 3 Cyl.

2 1 2 1

Exh. Exh.

Normally Open
De-Energized Energized

Exh. 3 Cyl. Exh. 3 Cyl.


2 1 2 1

Press. Press.

2
SERIES
4 NT8320

Dimensions: inches (mm)


with Quick Disconnect Connector (QDC)
QUICK DISCONNECT
6.23
[158]

3.88
1/2 NPT
[99]
1.95
2.06 [50]
[52]

2.78
[71]
.19 3.79 1.73
[5] [96] [44]
2.73
2 1 [69] 3

.37
[9]
“MOUNTING 1/4 NPT
SURFACE” 3 PLACES

.22 .85 .190-32 UNF-2B x .25 [6.4] DEEP .81


[6] [21] MOUNTING HOLES [21]
2 PLACES

.44 1.40
[11] [36]

1.69
[43]

Ordering Example
NT Q X 8320G182 xxxxx 250/DC Z D
Nuclear Product Series Voltage Type
NT – 1-E safety related Base Catalog A – AC
Number Example D – DC

Coil type Selection Leads Length


Q – Coil with Quick Dis-Connector (QDC) see table below for details
MH – Leaded coil with diode
Voltage Value
Blank – Leaded wire coil without diode
48, 125 250/DC
120/60, 220/50
Option Feature
X – with 5 digits number Option Feature Code (TPL) Number
Blank – without 5 digits number see table below for details

Optional features table – “X” with 5 digits number Field side QDC ordering information
Valve Feature Option “X” with Option Number Lead Wire Type Field Side QDC P/N
Valve with Suppression Diode Coil with ASCO QDC** 27253 PEEK Lead Wires G437960-001-[ ]*
Valve with Standard Coil with ASCO QDC 27252 Jacketed Silicone Lead Wires G437960-002-[ ]*
Valve with Fiberglass Jacketed Silicone Lead Wire** 27233
Note: ** Suppression Diode Coil is for DC voltages only.

Lead length information for leaded coil & QDC field side
Length Code Length (in)
D 18 (standard)
K 72
W 240
Z 360
3
SERIES
NT8320 4
Environmental Qualifications
• IEEE 323-1974/1983/ 2003
• IEEE 382-1996/ 2006
• EMC Type Testing: Meets Regulatory Guide 1.180
• Up to 170 Megarads Gamma Radiation
• 20,000 Mechanical Cycles

Design Basis Event


• HELB: 14 days @ 485°F (251°C) Peak plus 30 days post accident aging , covers
AP1000 Zones 5 & 10
• LOCA: Double Peaks, 30 days @ 440°F (227°C) Maximum, covers IEEE 323-1983/2003;
AP1000 Zone 1, Groups 2, 3, 7, 9 (Mild Environment), Group 6 (Harsh Environment)

Seismic Qualification
• IEEE 344-1975/1987/ 2004
• Required Input Motion (RIM) Operation Basis Earthquake (OBE): 4.0 g peak; Safe Shutdown
Earthquake (SSE): 6.0 peak at 2.0-64.00 Hz
• Certified Seismic Design Response Spectra (CSDRS) & Hard Rock High Frequency (HRHF)
SSE input: 6.0 g’s @ 5% damping