Sunteți pe pagina 1din 36

HALFEN PRECAST PANEL ANCHORS FB 07.

1-E

FAÇADE
HA LF E N
Global market leader for fixing systems for concrete façades

MST.factory,
HTP Husemann,
Timmermann and partner,
Braunschweig

Hotel Royal Meridien,


Engineering consultants
Windels, Timm, Morgen,
Hamburg

Alexa Berlin,
Ortner & Ortner, Berlin/
RTKL, Baltimore,
Berlin
HA LF E N
Global market leader for fixing systems for concrete façades

Basic planning information for the concrete façade


You want to implement your ideas
In this catalog, you will find all the necessary constructional planning and dimen- from the planning safely and eco-
sioning information and details necessary for the constructive design of concrete nomically.
façades.
Innovative production techniques
In addition, we support you in your planning with our HALFEN Software, through of the prefabricated concrete works
the support consultation of our representatives and the project work of our techni- and the new, self-sealing types of
cians. concrete make new and modern
surface structures possible, together
The products from HALFEN offer safety and quality and protection for you and with a wide range of façades con-
your company. nectors from high quality, efficient,
practical and sophisticated prefabri-
cated concrete components.

The suspended panel These façades will be secured to


the load-bearing construction of
▪ Many types of architecture the building as independent, thin
▪ Economical façade elements . In doing this, a
▪ Fast installation differentiation is made between
▪ High insulation thicknesses the following types of construction:

▪ suspended façade panels


▪ angled panels
▪ parapet elements

This catalog presents the necessary


The angled panel anchoring and fixation elements
for various types of construction
▪ Aesthetic building isolation for concrete façades.
▪ Avoidance of cold bridges
▪ Fast installation and storage HALFEN will assist you with its ex-
tensive experience and its compre-
hensive range of products from the
start of the planning, through the
dimensioning and static consulta-
tion up to the installation of the
constructions.
We will thereby support you in the
The parapet panel realization of your planning.

▪ Higher level of prefabrication


▪ Many types of architecture
▪ Safe and quick installation

3
HA LF E N F I X A T IO N S YS TE MS F O R C ONCR ETE FAÇADES
Contents

FPA-3 Page 7 FPA-5 Page 8 FPA-5S Page 8

ed
ed

ov
ov

pr
pr

-ap
-ap

pe
pe

Ty
Ty

Façade panel anchors with cast-in Façade panel anchors with cast-in part Façade panel anchors with cast-in part
part in the façade element and in the in the façade element. Fixation of the in the façade element. Fixation of the
supporting structure (cast-in part); installation part to the supporting struc- installation part from the side with
connected together by installation ture with either HALFEN HB anchor HALFEN HB anchor bolt to the sup-
parts. bolts or HALFEN cast-in channels. porting element.

FPA-S FPA-5Z Page 8 FPA-5A / FPA-5AZ Page 9

Façade panel anchors with HALFEN Façade panel anchors with cast-in Façade panel anchors for roof parapet
cast-in channel as cast-in part in the part in the façade element and with with cast-in part in the façade element
façade element and with fixation of two-point suspension of the installation and with HALFEN HB anchor bolt
the installation part to an HALFEN HB parts to the supporting structure. fixation of the installation part to the
anchor bolt or to a HALFEN cast-in supporting structure.
channel.

4
HA LF E N F I X A T IO N S YS TE MS CO NCRETE FAÇADE
Contents

WPA Page 14 Horizontal anchors / Pinnings Page 17-27

Spacer bolts DS Wind anchors WDI/WDK


Page 17-19 Page 22/23

ed
ov
pr
-ap
pe
Ty

Adjustable restraints LD Restraint with turnbuckle SPV


Page 20 Page 21
Top fixing dowel: Supporting anchor
or dowel suspension for corner panels
as the upper roof fixation

BRA Page 28
ed
ov
pr
-ap
pe
Ty

Restraint ties HKZ Pinning HFV


Page 24/25 Page 26/27

Parapet corbel: for taking up large


forces in parapet or roof elements or
for the deflection-resistant anchorage
of other prefabricated concrete parts
to the supporting concrete construction

Universal tie Page 30 Software Page 31 Fundamental static calculations Page 32/33

HALFEN FASSAD
ENPLAT TENANK ER
Statische G
rundlagen

Bemessung
der Ankerkr
äfte HA LF
EN
Einwirkungen: Sta
tisc BR ÜS
G = Vertikalgew
he
Gru TU NG
icht aus anteiligem ndl SA NK
Bei symmetrisch Eigengewicht age
er Aufhängung der Platte Ein n ER
ist G pro Anker wir
= ½ Gewicht kun
W = Windlast der Platte gen
pro Horizontala Einw , Te
Bei unterschied nker (¼¼ Windlast auf irku
ngen:
ilsi
lichen Überstände Platte) G = che
rhe
Spitzensog
pitzensog sind n der Abstützung
en oder bei
V V1 =R Eigenge itsb
die Horizontalla wic eiw
wd d = 1,25 x cp sten genauer zu Hd = Vertikallas ht erte
x q x antlg. A bestimmen
wss = 1,1 x cp W = Horizon t (Blu
x q x antlg. A Win tallast mentro
dlast (Ho g)
Teilsich lmd Sta
lt. Gutachten globale ruck) tisc
D
erheits he
Sicherheit von γG = o
Sys
1,2 gegen Abheben beiw tem
γQ = α 1,35 h2 erte für e
Teilsicherhe
icherheitsbe 1,5 (Eig Einw
itsbeiwerte
iwerte für Einwirkunge enla irku
γG n: H (Verke st) ngen:
= 1,35 ständige Einwirkung hrslaste
γQ = 1,50 veränderlich (Eigenlast) n) H
e Einwirkung (Windlast)
W Bem
Ankerkräfte:
räfte: h essung
Vd = Vertikale Kraft (siehe h1
Hd im Anker = G 1. auch V
= Horizontalkraft x γG V Typens a1
Rd im Anker = V tatik)
= Resultierend d x tan α 2.
h1

e Schrägzugkraft e L
im Anker = Wurzel
Dod (Vd 2 + Hd 2) Z
= Horizontalkraft 3.
Dud oben (aus Do
= Horizontalkraft g,d + Dow,d ) Du te
unten (aus Du My
2

g,d + Duw,d )
h/

Dog,d = Horizontalk
max Dow,d = Horizontalk raft oben aus Eigengewich f b aus
t x γG Eige Mi
min Dow,d = Horizontalk raft oben aus Wind (wd x ngewic W
raft oben aus γQ) ht D
ew

Dug,d = Horizontalk Wind (ws x γ aus Z


Q) Vertika
max Duw,d = Horizontalk raft unten aus Eigengewich 4. llast
t x γ (Blu
min Duw,d = Horizontalk raft unten aus Wind (wd x
G aus WV
Horizon mentro
raft unten aus γQ) g)
Wind (ws x γ h1 tallast
Q) aus (Ho
2

Win
h/

Bedingung: Du d lmd G
ruck) 65
Wenn min Do aus
d < 0 → Sogsicherun Vertika y
Wenn min Du g erforderlich 50
d < 0 → Sogsicherun (z.B: Luftspaltdre lversch
g erforderlich hanker) b
(z.B: Luftspaltdre α = Neigungswi iebung f
Berechnung: hanker) nkel (Tab. 7 bzw.8)
ΣMA → Du
g,d = Hd x h +
2 Vd x e / h
max Dud = Du 1
g,d + max Du Tabe
min Dud = Du wd Befe
lle 27 mit
stigu Befe
g,d – min Du Half stigu
w,d ensc ng ng
HTA hien
ΣH → Dog,d = H – Du Half - Fz ,Rd
e HTA
BRA
d ensc und
max Dod = Do
g,d HS - hrau
be HS
[kN] 40/ 1
Fz ,R 25
g,d + max Do d 11,2 BRA
wd
min Dod = Do [kN] M12 49/ 2
g,d – min Do Tabe
lle 28
30
w,d 13 16,8 BRA Bitte
Bean Bean 49/ 3 tigen Verwend
Mpl,y,d spruchba spru M16 30
rkeit chba
rkeit 24,2 16,8 BRA unse Ankerty en Sie
Mpl,z,d 4 re Bem ps und für die
[kNc M16 49/
Npl,d m] essu Auswah
[kNc BRA
1 24,2 16,8
30
BRA ngss den stat
Vpl,z,d m] oftw isch l
[kN]
203
M16 54/ 5 are. en Nacdes rich
[kN]
185 BRA
2 24,2 30,8
33
BRA hwe -
137 is
244
M20 54/ 6
44 228 BRA 33
3 37,8 30,8 BRA
148 420 54/ 7
32 M20 33
46 398 BRA
4 37,8 30,8 BRA
231 631 54/ 8
M20 33
73 599 BRA
5 37,8 30,8
279 879
M20
86 816 BRA
6 37,8
374 120
4
119 108 BRA
6 7
427 152
9
136 143 BRA
7 8
540 210
6
170 203
4
769
246

33

5
HALFEN Façade PANEL ANCHORS

FPA-3

Table 1 Load range Component parts e.g. FPA-3


Load range Resistance FPA - 3 - R: (cast-in part)
F FV,Rd
Support arm and recess former

[kN] [kN]
FPA - 3 - M: (installation part)
5.0 6.75
Perforated strap with locating pin,
8.0 10.80
nut, U-washer and locking bolts
11.5 15.53
16.0 21.60
FPA - 3/5 - E: (cast-in part)
22.0 29.70
Cast part with angle cleat and recess
34.0 45.90
former
46.0 62.1
56.0 75.6
FPA - 3 - G: (complete set)
FPA - 3 - R
+ FPA - 3 - M
+ FPA - 3 - E

FPA-3/5-E cast-in part for the prefabricated element

The assembly and installation instructions


The cast-in parts for the façade panel anchors are the same for all models and can be selected
and the color coding can be found on
from the following table.
Pages 12-13.

fmin
y
ed
ov
pr

30°
-ap
pe

dbr min c
Ty

br
e

z
w

m n

cr min
Øx
The stirrup is cropped for
the load range ≥ 34 kN

Table 2 FPA-3/-5-E cast-in parts for prefabricated elements in mm


Load Façade slab cast-in part FPA-3/5-E suitable for FPA-3-R, FPA-5, FPA-5S, FPA-5A, FPA-5AZ Steel reinforcement stirrup (user supplied)
range f br cr
[kN] c e m n w Øx y z
min min min
5.0 70 * 50 107 120 22 11 40 107 6 - 250
8.0 70 * 60 112 130 28 13 40 116 6 - 250
11.5 80 * 70 122 140 36 14 46 133 8 - 250
16.0 80 * 80 132 160 39 18 50 148 8 - 350
22.0 90 100 132 160 42 21 50 151 8 - 400
34.0 100 110 160 200 52 25 50 164 10 25 500
46.0 115 140 180 220 62 30 50 166 12 42 500
56.0 125 150 180 230 69 35 50 173 12 52 600
* under compliance with Cmin

6
HALFEN Façade PANEL ANCHORS

FPA-3
ed
ov
pr
-ap

ro
dmin
pe
Ty

ar min
b a

dbr =4xds
to

p
hx see Table 6

g
α
ds

Order spacer
bolt and sleeve
separately,
see Page 17

[mm]

Component part FPA-3 Example of the anchor designation:

FPA - 3 - R: : (cast-in part) FPA - 3 - G - 16.0 - 200


support arm and recess former Product
FPA - 3 - M: : (installation part) Type
perforated strap with locating pin, Component part
nut, U-washer and locking bolts Load range
FPA - 3 - E: (cast-in part) Cavity b
Cast part with angle cleat and recess
former
FPA - 3 - G: (complete set)
FPA - 3 - R
+ FPA - 3 - M Steel reinforcement stirrups made from BSt 500 S
are not included in the component part.
+ FPA - 3 - E

Table 3 Dimensional table FPA-3-R


Load Perforated Installation lateral separati- Stirrup
range strap angle depth on of edge
to ro p
ds g
α a dmin ar min
[kN] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
5.0 25.0° 81 100 70 121 38 38 6 200
8.0 25.0° 85 115 80 130 40 38 6 200
11.5 25.0° 96 125 90 150 45 50 8 200
16.0 25.0° 115 140 120 165 50 55 8 250
22.0 22.5° 134 160 130 179 60 59 10 250
34.0 22.5° 155 180 150 202 70 72 12 300
46.0 20.0° 190 240 170 236 80 86 16 350
56.0 20.0° 213 300 200 255 94 95 16 400
With utilization of ar min large values for dmin will be necessary
You can find more information about the perforated strap on Page 11.

7
HALFEN Façade PANEL ANCHORS

FPA-5 FPA-5Z
ed
ov
pr

ar
-ap

b dmin b dmin ar
pe
Ty

sZ
d
dZ
hx see table 7

hx see table 7
α α

[mm] [mm]

part FPA-5 FPA-5 Example of the anchor designation:


Information regarding the use of
FPA - 5 - M: (installation part) FPA - 5 - G - 16.0 - 200 fixations for the façade anchors
Perforated strap with nut and washer, Product We recommend the use of HTA
locking bolts and slotted strap Type cast-in anchor channels or HALFEN
FPA - 3/5 - E: (cast-in part) ( 5 / 5Z ) anchor bolt suitable for the tension
Cast part with angle cleat and recess Component part zone. If anchors are used that are
former Load range not suitable for the tension zone,
Cavity b the reliability of their use must be
FPA - 5 - G: (complete set) clarified in advance.
FPA - 5 - M Order spacer bolt and socket seperatly All fixings must be calculated with
+ FPA - 5 - E see page 17 the loads that are present.

Table 4 Dimensional table FPA-5 and FPA-5Z


Load Perforated Variation in angle α for smaller cavities Hole diameter sZ
range strap Cavity installation part
b
α [mm] d dZ
[kN] 60 70 80 90 100 110 120 >120 [mm] [mm] [mm]
5.0 25.0° 18.5° 21.5° 25.0° 25.0° 25.0° 25.0° 25.0° 25.0° 13 8.5 120
8.0 25.0° 18.5° 21.5° 25.0° 25.0° 25.0° 25.0° 25.0° 25.0° 17 10.5 135
11.5 25.0° 16.5° 19.0° 22.0° 25.0° 25.0° 25.0° 25.0° 25.0° 21 12.5 160
16.0 25.0° 14.5° 17.0° 19.5° 22.5° 25.0° 25.0° 25.0° 25.0° 21 12.5 160
22.0 22.5° 13.5° 15.5° 18.0° 20.0° 22.5° 22.5° 22.5° 22.5° 21 16.5 170
34.0 22.5° - 14.0° 16.0° 18.5° 20.5° 22.5° 22.5° 22.5° 25 22.5 190
46.0 20.0° - - - - 16.0° 18.0° 20.0° 20.0° 28 25.0 250
56.0 20.0° - - - - - 15.0° 17.0° 20.0° 31 25.0 315
reduced tolerance range.
dmin and ar depend on the fixation system.
you can find more information about the perforated straps on Page 11.

8
HALFEN Façade PANEL ANCHORS

FPA-5A FPA-5AZ

b ar b ar sZ
d variable dZ variable
hxA see table 7

hxA see table 7


α α

[mm] [mm]

Component parts for FPA-5A Example of the anchor designation: Order the spacer bolt and socket separately,
see page 17
FPA - 5A - M: (installation part) FPA - 5A - G - 16.0 - 200
Perforated strap with nut and washer, Product
locking bolts, slotted strap and corner Type
protection ( 5 / 5Z ) e1
ar
FPA - 3/5 - E: (cast-in part) Component part
Molded part with angle cleat and Load range d
recess former Cavity b

FPA - 5A - G: (complete set) slotted strap FPA-5A


FPA - 5A - M
+ FPA - 5 - E

Table 5 Dimension table FPA-5A and FPA-5AZ


Load Perforated Variation in angle α for smaller cavities Hole diameter Loch- Rand-
range strap Cavity installation part abstand abstand
b nur FPA-5A nur FPA-5A
α [mm] d dZ e1 ar
[kN] 60 70 80 90 100 110 120 >120 [mm] [mm] [mm] [mm]
5.0 25.0° 18.5° 21.5° 25.0° 25.0° 25.0° 25.0° 25.0° 25.0° Ø 11 Ø 8.5 24 110
8.0 25.0° 18.5° 21.5° 25.0° 25.0° 25.0° 25.0° 25.0° 25.0° Ø 13 Ø 10.5 28 135
11.5 25.0° 16.5° 19.0° 22.0° 25.0° 25.0° 25.0° 25.0° 25.0° Ø 17 Ø 12.5 37 155
16.0 25.0° 14.5° 17.0° 19.5° 22.5° 25.0° 25.0° 25.0° 25.0° Ø 21 Ø 12.5 46 210
22.0 22.5° 13.5° 15.5° 18.0° 20.0° 22.5° 22.5° 22.5° 22.5° Ø 21 Ø 16.5 46 210
34.0 22.5° - 14.0° 16.0° 18.5° 20.5° 22.5° 22.5° 22.5° Ø 25 Ø 22.5 55 260
46.0
on request
56.0
reduced tolerance range.
ar quote ar when ordering.
you can find more information about the perforated straps on Page 11.

9
HALFEN Façade PANEL ANCHORS
Table for the selection of the correct hole in the perforated strap

Dimensional table perforated strap

FPA-3 FPA-5 und FPA-5Z FPA-5A and FPA-AZ

b b

hx hx hxA

Table 6 Table 7

Table 6 FPA-3, Dimensional table perforated strap


Load range 5.0 kN 8.0 kN 11.5 kN 16.0 kN 22.0 kN 34.0 kN 46.0 kN 56.0 kN
Thread M8 M10 M12 M14 M16 M20 M27 M30
t [mm] 11 13 17 21 21 25 28 31
u [mm] 21 25 33 41 41 50 56 62

Cavity
b hx L Z hx L Z hx L Z hx L Z hx L Z hx L Z hx L Z hx L Z
[mm]

60 120 251 130 284 120 283 125 320 155 378 155 392 195 458 210 499
70 145 293 150 309 145 316 145 361 180 378 180 442 225 514 235 561
80 165 314 170 334 165 349 170 361 205 419 205 442 250 514 265 561
435 453 515 630 724 794
90 185 335 195 359 185 506 382 190 402 230 614 440 225 492 280 570 290 623
(12) (10) (6) (6) (6) (6)
100 205 356 215 384 205 (8) 382 210 402 230 (8) 460 250 492 305 570 320 623
110 230 377 235 384 230 415 235 443 275 501 275 542 330 626 345 685
120 250 398 260 409 250 448 255 443 300 501 300 542 360 626 375 685
130 270 419 280 434 270 448 275 484 325 542 325 592 385 682 400 747
140 295 461 300 459 295 481 295 525 350 583 345 592 415 682 430 747
150 315 482 325 484 315 514 320 525 370 583 370 642 440 738 455 747
160 335 503 345 509 335 547 340 679 566 395 624 395 642 465 738 485 809
653 (6)
170 360 645 524 365 534 355 547 360 566 420 665 420 692 495 948 794 510 809
(10) 830
180 380 (12) 545 385 559 380 580 385 607 445 665 445 692 520 (6) 794 540 1042 871
704 (6)
190 400 566 410 584 400 613 405 648 470 860 706 465 742 550 850 570 (6) 871
(8)
200 420 587 430 609 420 613 425 648 490 (8) 706 490 742 575 906 600 933
210 440 608 450 634 440 646 515 747 510 742 600 906 625 933
220 460 629 460 646 540 747 535 792 625 906 650 933
230 485 679 565 788 560 792 675 995
240 505 679 590 788 705 995
250 615 829
For the number of holes, refer to the values in the brackets

10
HALFEN Façade PANEL ANCHORS
Table for the selection of the correct hole in the perforated strap

Dimensional table perforated strap

loose locking bolts

L
u

M
t

Axis of the pre-selected


hole for the fixation Z

Table 7 FPA-5, Dimensional table perforated strap


Load
5.0 kN 8.0 kN 11.5 kN 16.0 kN 22.0 kN 34.0 kN 46.0 kN 56.0 kN
range
Thread M8 M10 M12 M14 M16 M20 M27 M30
t [mm] 11 13 17 21 21 25 28 31
u [mm] 21 25 33 41 41 50 56 62

Cavitiy
b hx hxA L Z hx hxA L Z hx hxA L Z hx hxA L Z hx hxA L Z hx hxA L Z hx hxA L Z hx hxA L Z
[mm]

60 185 170 167 185 195 184 210 - 217 240 - 238 260 - 255 - - - - - - - - -
70 180 165 167 180 190 184 210 215 217 235 - 238 260 - 255 285 - 292 - - - - - -
246
80 175 160 167 175 180 278 184 205 210 217 230 245 238 255 260 255 285 - 292 - - - - - -
(4) 341
90 200 180 188 195 175 (4) 184 200 205 217 225 240 238 250 255 255 280 285 292 - - 346 - - -
(4) 392 409
100 220 200 209 215 195 209 220 200 217 220 230 238 245 250 255 275 275 292 380 - 346 - - -
(4) (4) 480 556
110 240 220 230 240 220 234 240 220 250 245 220 238 270 240 296 270 270 292 365 - 346 450 - 437
(4) (4)
120 265 245 251 260 240 259 265 240 283 265 240 279 290 265 296 295 265 292 365 - 346 450 - 608 437
130 285 265 272 280 260 284 285 260 316 285 260 279 315 290 337 320 290 342 375 - 402 450 - (4) 437
140 305 285 435 293 305 280 309 305 280 316 310 285 320 340 315 337 340 315 342 385 - 402 450 - 437
453
150 325 305 (12) 314 325 305 334 325 305 349 330 305 361 365 335 378 365 335 392 410 - 402 450 - 437
(10) 506
160 350 330 335 345 325 359 350 325 382 350 325 361 390 360 419 390 360 392 435 - 458 450 - 437
(8) 515
170 370 350 377 370 350 384 370 345 382 375 345 402 410 385 614 419 415 385 442 465 - 458 465 - 437
(6)
180 390 370 398 390 370 409 390 365 415 395 370 402 435 410 (8) 460 440 410 442 490 - 458 495 - 499
190 415 395 419 410 390 434 415 385 448 415 390 443 460 435 501 460 435 630 492 520 - 514 520 - 499
724
200 435 415 440 430 415 459 435 410 448 440 410 443 485 460 501 485 460 (6) 492 545 - 514 550 - 499
(6)
210 455 440 440 450 435 459 455 435 481 460 435 484 510 485 501 505 475 492 570 - 570 575 - 561
220 475 460 461 475 460 484 475 455 481 480 455 484 535 510 542 530 500 542 595 - 570 600 - 794 561
230 495 480 482 495 480 653 509 500 480 514 500 475 525 560 535 583 555 525 542 620 - 626 625 - (6) 623
645
240 520 505 524 515 500 (10) 534 520 500 547 520 495 525 580 555 583 580 550 592 650 - 626 655 - 623
(12) 704 679
250 540 525 545 540 525 559 540 520 547 545 520 566 605 580 624 605 575 592 675 - 682 680 - 685
(8) (6)
260 560 545 566 560 545 584 560 540 580 565 540 566 630 605 665 630 600 642 705 - 682 710 - 685
860
270 580 565 587 580 565 609 585 565 613 585 560 607 655 630 665 655 625 642 730 - 738 735 - 747
(8) 830
280 605 590 608 605 590 634 605 585 646 605 580 607 680 655 706 680 650 692 760 - 948 738 765 - 747
(6)
290 625 610 629 625 605 646 630 605 648 705 680 706 705 675 742 785 - (6) 794 790 - 747
300 650 630 679 650 625 648 730 705 747 725 695 742 815 - 794 820 - 1042 809
310 755 730 788 750 720 742 840 - 850 845 - (6) 809
320 775 750 788 775 745 792 870 - 850 875 - 871
330 800 775 829 800 770 792 895 - 906 905 - 871
340 930 - 871
350 960 - 933
For the number of holes, refer to the values in the brackets hx for FPA-5 / 5Z
For these cavities, the matching spacer bolts are available on request. hxA for FPA-5A / 5AZ

11
HALFEN Façade PANEL ANCHORS
Installation of the façade panel anchors FPA-3 and FPA-5

Mounting of the lower cast-in element FPA-3/5-E Installation of the cast-in support FPA-3-R

1.1 The cast-in part FPA-3/5-E, consisting of molded part, 2.1 Place the recess former onto the support arm.
angle cleat and polystyrene recess former, is delivered
pre-assembled. 2.2 Insert the reinforcement stirrup through the rear holes in
the frame of the support arm.
1.2 The reinforcement stirrups are inserted into the holes
provided. 2.3 Attach the cast-in support to the formwork with 2 nails
(securing with additional reinforcement where neces-
1.3 Secure to the formwork with nails. Nail holes are pro- sary).
vided for this on the molded part and on the angle cleat.

Fig. 1.1 Fig. 2.1


molded part

polystyrene
angle cleat recess former
molded part

polystyrene
recess former

Fig. 1.2 Fig. 2.2


reinforcement
(customer supplied)

reinforcement
(customer supplied)

Fig. 1.3 Fig. 2.3

wooden board as
temporary construction

12
HALFEN Façade PANEL ANCHORS
Mounting of the façade panel anchors FPA-3 and FPA-5

Mounting the perforated strap Assembly of the pre-cast panel 1.1-2.3 FPA-5 / 3.1-3.2FPA-3

1.1 Remove the polystyrene recess former. Any polystyrene 2.1 Mount the slotted strap onto the threaded rod of the
remaining in the gap between the molded part and perforated strap using a nut and washer.
angle cleat can be pushed out with the perforated strap.
2.2 Fix the upper part on the mounted dowel or rail.
1.2 Insert the perforated strap between the molded part and
the angle cleat. 2.3 Since 12/07 we have coated nuts. Molykote® is not
necessary than and adjust the complete assembly on the
1.3 Roughly adjust the required length of the perforated strap slotted strap.
Fig. 2.2
according to Table 6 or 7 on Pages 10 and 11. Lock the
Fig. 2.1
perforated strap using the locating pins (thereby turning
the pins through 180°) and bend over the angle cleat.

1.4 Tighten the nuts to the torque values listed in Table 8.

Fig. 1.1

slotted strap
Fig. 2.3
Fig. 1.2

Fig. 1.4
3.1 Mount the locating pin, washer and nut on the threaded
rod of the perforated strap and suspend from the cast-in
part.
3.2 Adjust the complete assembly on the support arm. The
complete assembly remains hanging on the construction
locating pin crane during the adjustment.

Fig. 1.3
Fig. 3.1

Table 8: Recommended tightening torque for façade panel cast-in parts


Load range Tightening Spanner size Colour code locating
Fig. 3.2 pin
[kN] [Nm]
5.0 5 13 yellow
8.0 5 13 red
11.5 10 17 blue
16.0 15 19 green
22.0 15 19 brown
34.0 30 24 black
46.0 60 30 orange
56.0 60 30 white

13
HA LF E N T O P F IXING DO WE L

WPA-A/-B

The top fixing dowel permits a height


adjustment of ± 20 mm (with b = 20
mm : +15/-10 mm). One dowel should
always be fitted with a plastic sleeve to
allow for thermal expansion.

Type WPA -B
(with plastic sleeve
to allow thermal
expansiong)
WPA -A
(fixed point)

Ordering example: WPA-A-11.5-60


Product
Type
Load range (kn)
Dimension b (mm)

Anchor dimensioning
a
M
square threaded plate Øp
(rotating)

H
g lg b

c
l

lt
V

Ød
Du

Individual certification:
Not necessary if max. H and max. V are complied with according to the table.
d

Example: Given: V = 10.0 kN


H = 2.0 kN
b = 8 cm
Dimensioning:
Pre-selection of a load range Pre-selection = Load range 11.5
Nd = 1.35 * V [kN] Nd = 1.35 * 10.0 = 13.5 kN
Md = 1.4 * H * (b+Ød) [kNcm] Md = 1.4 * 2.0 * (8.0 +2.9) = 30.52 kNcm
Nd / (κ*NRd) + Md / My,Rd + temp ≤ 1.0 13.5 / 94 + 30.52 / 57.2 + 0.26 = 0.937 < 1.00

14
HA LF E N T O P F IXING DO WE L

Table 9 Top fixing dowel WPA


Load range- Top cavity
κ*NRd My,Rd temp max H d Thread Ød x L lg + lt ax g Øp min c
Cavity Distance
max V b M
[kN] [cm] [kN] [kNcm] [-] [kN] [cm] [mm] [mm] [mm] [mm] [mm]
2.0 64 0.12 2.20 15
4.0 58 0.16 1.55 15
5.0 24.9 M24 x 1.5 22 x 295 135 + 160 110 x 10 60 160
6.0 53 0.20 1.15 15
8.0 49 0.24 0.88 15
2.0 99 0.10 3.90 20
4.0 92 0.13 2.90 18
8.0 46.1 M28 x 1.5 27 x 295 135 + 160 115 x 10 70 160
6.0 86 0.16 2.20 16
8.0 80 0.19 1.75 15
2.0 115 0.14 4.20 20
4.0 108 0.18 3.10 18
11.5 57.2 M30 x 1.5 29 x 330 140 + 190 120 x 12 70 190
6.0 101 0.22 2.30 16
8.0 94 0.26 1.75 15
2.0 161 0.13 6.50 26
4.0 153 0.16 4.80 22
16.0 92.1 M35 x 1.5 34 x 335 145 + 190 125 x 12 70 190
6.0 144 0.20 3.70 20
8.0 136 0.23 2.90 18
2.0 204 0.13 8.40 30
4.0 194 0.17 6.30 24
22.0 128.5 M39 x 1.5 38 x 365 145 + 220 140 x 15 80 220
6.0 184 0.20 4.85 22
8.0 175 0.24 3.85 20
2.0 277 0.14 11.50 34
4.0 265 0.18 8.80 30
34.0 199.6 M45 x 1.5 44 x 395 145 + 250 140 x 15 80 250
6.0 254 0.21 6.80 25
8.0 243 0.25 5.40 23
The values take a vertical adjustment range of ± 20 mm into consideration

Assembly and installation instructions

1. A recess (grout hole) is provided in 3. A recess is provided in the precast 5. The tapped plate is moved. Adjust-
the structure for the threaded bolt, part for the grouting of the dowel ment is carried out horizontally in
or the bolt may be cast directly once it has been aligned. the grout recess and vertically with
into the concrete, whereby it must 4. The thread is left exposed, and the the using the tapped plate.
be ensured that the dowel remains tapped plate is turned onto it and 6. After the adjustment, the recess
completely perpendicular. pre-adjusted. in the panel is filled with concrete
2. The dowels must be grouted verti- (concrete strength ≥ 25 N/mm²).
cally into the recesses in the struc- The position of the corner panel
ture (if they are not directly cast in) must be secured until the concrete
(≥ C30/37). grout has hardened.

15
OV E R V I E W OF HA LF E N HO RIZO NT AL AN CH ORING / D OW EL R ESTR AINTS

General information Spacer bolts

Pages 17-19
Horizontal anchors are used for the The selection of the product version

ed
ov
pr
horizontal support of facing panels is made according to the loading, sec-

-ap
pe
Ty
(façade slabs). In principle, a differ- tion, distance and accessibility.
entiation is made between horizontal
fixations for the acceptance of pressure HALFEN-DEHA offers a wide range of
and/or tensile forces of panels that are anchors with different load ranges for
aligned to each other in parallel or at this application.
right angles, as well as for the align-
ment of panels arranged above or be-
low each other with dowel restraints. • High pressure strengths
• Cavities < 300 mm
type-approved

Tension and pressure resistant connection in the space between parallel surfaces

Adjustable restraint Page 20 Restraint with turnbuckle Page 21 Wind anchor Pages 22/23
LD SPV WDI / WDK

• Cavity 60-300 mm • Cavity 100 - 200 mm • Installation from the front


• Tensile load < 6.0 kN • Load up to 10.0 kN • Tension and pressure resistant
• Compressive load connection
(dependent on the spacer bolt) • Loading
WDK bis 3.0 kN, WDI bis 7.0 kN

Tension and pressure resistant con- Dowel restraint fixings Universal tie
nection for lateral orthogonal surfaces

Restraint tie Pages 24/25 Dowel restraint fixings Pages 26/27 Universal tie Page 30
HKZ HFV ULZ

Hammer-head restraint in various mo- • Load up to 5.0 kN


dels for tensile and pressure loadings

16
HA LF E N H O R I ZO NTA L A NCHO RING / D OW EL R ESTR AINTS
HALFEN spacer bolts

DS 13 DS 18 DS 25

with tensile and compressive sockets with pressure plate with compressive socket
Can be screwed on from the front
ed
ov
pr
-ap

06
pe

20
Ty

W
NE
Plastic socket DS 1
DS 3 DS 1 DS 7 (separate) DS 2
DS 5

DS 8 pressure
plate + nut

Spacer bolt DS - 13 Spacer bolt DS - 18 Spacer bolt DS - 25


consisting of tensile/compressive consisting of: pressure plate DS 8 consisting of: compressive socket DS 5
socket DS 3 + nut spacer bolt DS 2
spacer bolt DS 1 spacer bolt DS 1
The plastic socket DS 7 must be The DS 5 socket is open ended, allow-
ordered separately. ing the DS 2 bolt, which has a slot on
the end of its shank, to remain adjust-
DS-18 and DS 25 are not suitable for able, even after assembly.
use as adjustable restraints with LD.

Tensile/Compressive Tensile/Compressive Ordering example: DS-13-10-100


sockets sockets Product
e Type
Thread
L DS 3 Cavity b
DS 1 e

L DS 7
LH
LH

Component parts:
DS 2
e
with slot
e DS 13: Spacer bolt DS 1 and tensile/
e compressive socket DS 3
DS 18: Spacer bolt DS 1 and pressure
DS 8 plate DS 8 including nut
LH DS 25: Spacer bolt DS 2 and socket
DS 5 DS 5 accessible from panel
surface

Table 10 Dimensions of the sockets and pressure plates in mm


M10 M12 M16 M20 M24 M27 M30
Type
LH e LH e LH e LH e LH e LH e LH e
DS 3 58 50 59 50 64 50 72 70 75 70 80 80 90 90
DS 7 70 41 70 41 80 45 80 50 - - - - - -
DS 8 - 50 - 50 - 50 - 70 - - - - - -
DS 5 50 50 50 70 70 - - - -
Please quote the length and plate thickness when ordering (for DS5, LH = f)

17
HA LF E N H O R I ZO NTA L A NCHO RING / D OW EL R ESTR AINTS
Dimension of the HALFEN spacer bolts

Length of the spacer bolts

DS 13 DS 18 DS 25

f b f b f b

L L L

DS1 and DS2 (M10-M20) DS1 DS2 (M24)

L
L
60 h 7
s h
60

M
M

Table 11 Lengths of the spacer bolts


Product M10 M12 M16 M20 M24 M27 M30
s 19 24 30 41 36 41 46
h 8 10 13 16 18 20 24
Spacer bolt DS13/25 DS 18 DS13/25 DS 18 DS13/25 DS 18 DS13/25 DS 18 DS13/25 DS 18 DS13/25 DS 18 DS13/25 DS 18
b = 40 mm 70 90 72 92 75 95 80 100 - - - - - -
b = 60 mm 90 110 92 112 95 115 100 120 105 - - - - -
b = 80 mm 110 130 112 132 115 135 120 140 125 - - - - -
b = 100 mm 130 150 132 152 135 155 140 160 145 - 145 - - -
b = 120 mm 150 170 152 172 155 175 160 180 165 - 165 - - -
b = 140 mm 170 190 172 192 175 195 180 200 185 - 185 - - -
b = 160 mm 190 210 192 212 195 215 200 220 205 - 205 - - -
b = 180 mm 210 230 212 232 215 235 220 240 225 - 225 - - -
b = 200 mm 230 250 232 252 235 255 240 260 245 - 245 - - -
b = 220 mm - - - - 255 275 260 280 265 - 265 - - -
b = 240 mm - - - - 275 295 280 300 285 - 285 - 285 -
b = 260 mm - - - - 295 315 300 320 305 - 305 - 305 -
b = 280 mm - - - - - - - - - - - - 325 -
b = 300 mm - - - - - - - - - - - - 345 -
Longer lengths on request

18
HA LF E N H O R I ZO NTA L A NCHO RING / D OW EL R ESTR AINTS
Load-bearing capacity of the HALFEN spacer bolts depending on the reinforcement

Table 12 Load-bearing capacity of HALFEN spacer bolts FD,Rd [kN] (with mesh reinforcement Q 188)
Spacer bolt M10 M12 M16 M20 M24 M27 M30
Pressure plate e [mm] 50 50 50 70 70 80 90
Plate thickness f [mm] 70 80 80 90 80 90 100 90 100 120 130 150 150 170 180 200
b = 60 mm 7.7 11.7 11.3 15.8 10.9 15.4 20.4 16.9 22.2 34.4 39.1 53.8 54.8 71.4 80.6 99.8
b = 80 mm 7.7 11.7 11.3 15.8 10.9 15.4 20.4 16.9 22.2 34.4 39.1 53.8 54.8 71.4 80.6 99.8
b = 100 mm 7.7 11.0 11.3 15.8 10.9 15.4 20.4 16.9 22.2 34.4 39.1 53.8 54.8 71.4 80.6 99.8
b = 120 mm 7.7 9.6 11.3 15.8 10.9 15.4 20.4 16.9 22.2 34.4 39.1 53.8 54.8 71.4 80.6 99.8
b = 140 mm 7.7 8.3 11.3 14.3 10.9 15.4 20.4 16.9 22.2 34.4 39.1 53.8 54.8 71.4 80.6 99.8
b = 160 mm 7.2 7.7 11.3 12.7 10.9 15.4 20.4 16.9 22.2 34.4 39.1 53.8 54.8 71.4 80.6 99.8
b = 180 mm 6.2 6.2 11.3 11.3 10.9 15.4 20.4 16.9 22.2 34.4 39.1 53.8 54.8 71.4 80.6 99.8
b = 200 mm 5.4 5.4 10.0 10.0 10.9 15.4 20.4 16.9 22.2 34.4 39.1 53.8 54.8 71.4 80.6 99.8
b = 220 mm 4.8 4.8 8.9 8.9 10.9 15.4 20.4 16.9 22.2 34.4 39.1 53.8 54.8 71.4 80.6 99.8
b = 240 mm 4.2 4.2 7.9 7.9 10.9 15.4 20.4 16.9 22.2 34.4 39.1 53.8 54.8 71.4 80.6 99.8
b = 260 mm 3.7 3.7 7.1 7.1 10.9 15.4 19.7 16.9 22.2 34.4 39.1 53.8 54.8 71.4 80.6 99.8
b = 280 mm 3.3 3.3 6.4 6.4 10.9 15.4 18.1 16.9 22.2 34.4 39.1 53.8 54.8 71.4 80.6 99.8
b = 300 mm 3.0 3.0 5.8 5.8 10.9 15.4 16.6 16.9 22.2 33.6 39.1 53.8 54.8 71.4 80.6 99.8

Table 13 Load-bearing capacity of HALFEN spacer bolts FD,Rd [kN] (with stirrup reinforcement)
Spacer bolt M10 M12 M16 M20 M24 M27 M30
Reinforcement Ø 6 8 8 10 10 12 12
Pressure plate e [mm] 50 50 50 70 70 80 90
Plate thickness f [mm] 70 80 80 90 80 90 100 90 100 120 130 150 150 170 180 200
b = 60 mm 9.2 14.4 13.6 21.3 12.9 20.4 26.8 20.6 29.9 46.1 51.4 67.4 75.2 94.4 104.3 124.9
b = 80 mm 9.2 12.7 13.6 21.2 12.9 20.4 26.8 20.6 29.9 46.1 51.4 67.4 75.2 94.4 104.3 124.9
b = 100 mm 9.2 11.0 13.6 18.1 12.9 20.4 26.8 20.6 29.9 46.1 51.4 67.4 75.2 94.4 104.3 124.9
b = 120 mm 9.2 9.6 13.6 16.1 12.9 20.4 26.8 20.6 29.9 46.1 51.4 67.4 75.2 94.4 104.3 124.9
b = 140 mm 8.3 8.3 13.6 14.3 12.9 20.4 26.8 20.6 29.9 46.1 51.4 67.4 75.2 94.4 104.3 124.9
b = 160 mm 7.2 7.7 12.7 12.7 12.9 20.4 26.8 20.6 29.9 46.1 51.4 67.4 75.2 94.4 104.3 124.9
b = 180 mm 6.2 6.2 11.3 11.3 12.9 20.4 26.8 20.6 29.9 46.1 51.4 67.4 75.2 94.4 104.3 124.9
b = 200 mm 5.4 5.4 10.0 10.0 12.9 20.4 25.7 20.6 29.9 46.1 51.4 67.4 75.2 94.4 104.3 124.9
b = 220 mm 4.8 4.8 8.9 8.9 12.9 20.4 23.5 20.6 29.9 44.5 51.4 67.4 75.2 94.4 104.3 124.9
b = 240 mm 4.2 4.2 7.9 7.9 12.9 20.4 21.5 20.6 29.9 41.5 51.4 67.4 75.2 94.4 104.3 124.9
b = 260 mm 3.7 3.7 7.1 7.1 12.9 19.7 19.7 20.6 29.9 38.7 51.4 64.8 75.2 92.3 104.3 119.9
b = 280 mm 3.3 3.3 6.4 6.4 12.9 18.1 18.1 20.6 29.9 36.0 51.4 61.2 75.2 87.9 104.3 114.7
b = 300 mm 3.0 3.0 5.8 5.8 12.9 16.6 16.6 20.6 29.9 33.6 51.4 57.7 75.2 83.6 104.3 109.7

f b r
ds
≥5
r

ds
≥6e

FD,Rd
≥10ds

≤3e

Table 14 Edge distances for mesh reinforcement and stirrup reinforcement


Plate thickness f [mm] 70 80 90 100 120 130 150 170 180 200
Edge distance r [mm] 105 135 165 195 255 285 345 405 435 495
• With smaller edge distances, the load-bearing capacity must be interpolated linearly in relation to the upper row b = 60 mm,
but may not be bigger than the load-bearing capacity for the selected cavity b
•Selected: „Example: Cavity b = 180 mm, Mesh reinforcement Q188, Plate thickness 80 mm, Edge distance 100 mm
M10: red FD,Rd = 11.7 * 100 / 135 = 8.67 kN, but bigger than 6.2 kN at b = 180 mm thereby FD,Rd = 6.2 kN“ (permissible. FD = 6.2 / 1.5 = 4.13 kN)

19
HA LF E N H O R I ZO NTA L A NCHO RING / D OW EL R ESTR AINTS
Tension and pressure resistant connection in the space between parallel surfaces

HALFEN LD adjustable restraint (suitable for tensile and compressive loads)

t Ordering example: LD-3.5


Product
Load range

ø
L
FRd
Component part:

x
ø17
• Adjustable restraint with set-screw
a

Table 15 HALFEN LD adjustable restraint


Order the spacer bolt separately
Load Max. load L a t x ± 15 Ø according to Pages 17-19.
Pro- range FRd Fixing to the HALFEN spacer bolt
duct channel
[kN] [kN] [mm] [mm] [mm] [mm] [mm]
2.0 3.00 157 40 10 38 11 HTA 28/15 HS 28/15 M10x40
Approved dowels can also be used in
LD 3.5 5.25 148 48 12 39 13 HTA 38/17 HS 38/17 M12x50 place of the HALFEN cast-in channel
6.0 9.00 171 60 15 49 17 HTA 49/30 HS 50/30 M16x60 and HALFEN spacer bolt.
Short pieces 150, 200 and 250 mm long must be ordered separately
The HALFEN spacer bolts must be ordered separately
For the permissible compressive forces, see “Spacer bolts” on Page 19 The HALFEN LD adjustable restraint
Installation: can be combined with the M10, M12
1. Insert the spacer bolt through the 3. Pre-mount on the HALFEN cast-in and M16 spacer bolts.
slot in the strap (with a washer when channel. When using with M10 spacer bolts,
using an M10 thread spacer bolt) 4. Adjust to be parallel to the wall us- DIN 9021 washers must be fitted
2. Screw the spacer bolt into the ing the adjusting screw. between the bolt head and the slot
socket and adjust. 5. Tighten the HALFEN spacer bolt. (order separately).

HALFEN LD-A adjustable restraint (suitable for tensile and compressive loads)

t
Ordering example: LD-A-3.5-12
06
20

Product
W
NE

Load range
Thread of the spacer bolt
L

FRd
x

Component part:
• Clamping fork
a

Tabelle 16 HALFEN LD-A adjustable restraint anchor


Order the spacer bolt separately
Load Max. load L a t x Spacer U-Washer according to Pages 17-19.
Pro- range FRd ±15 bolt Fixing to HALFEN spacer
duct the channel bolt
[kN] [kN] [mm] [mm] [mm] [mm] DIN
1.8 2.70 130 21 22 40 M12 HTA 28/15 HS 28/15 M10x50 DIN 9021
1.8 2.70 130 25 22 40 M16 HTA 28/15 HS 28/15 M10x50 DIN 9021
Application:
3.5 5.25 135 21 30 40 M12 HTA 38/17 HS 38/17 M12x60 DIN 125
LD-A 3.5 5.25 135 25 30 40 M16 HTA 38/17 HS 38/17 M12x60 DIN 125
Tension and pressure resistant connec-
3.5 5.25 135 29 30 40 M20 HTA 38/17 HS 38/17 M12x60 DIN 9021 tion of curtain facing panels with cast
6.0 9.00 135 27 35 40 M16 HTA 50/30 HS 50/30 M16x80 DIN 125 concrete construction.
6.0 9.00 135 31 35 40 M20 HTA 50/30 HS 50/30 M16x80 DIN 125 Adjustable in three directions.
Short pieces 150, 200 and 250 mm long must be ordered separately
The HALFEN spacer bolts must be ordered separately
For the permissible compressive forces, see “Spacer bolts” on Page 19

20
HA LF E N H O R I ZO NTA L A NCHO RING / D OW EL R ESTR AINTS
Tension and pressure resistant connection in the space between parallel surfaces

HALFEN SPV restraint with turnbuckle

FRd

L
b

Ordering example: Component parts:

SPV-7.0-100-A4
Product
Load range
Cavity
Material • Turnbuckle SPH,
• 2 HALFEN spacer bolts (1 right-hand
thread, 1 left-hand thread -Li-),
• 3 flat nuts,
• 2 washers and
• 2 lock washers SIC

Order the HALFEN channels separately

Table 17 HALFEN SPV restraint with turnbuckle


Load range [kN] ±5.0 ±7.0 ±10.0
Max load FRd [kN] ±7.0 ±9.8 ±14.0
Cavity HALFEN spacer Turn- HALFEN spacer HALFEN spacer Turn- HALFEN spacer HALFEN spacer Turn- HALFEN spacer
bolt left-hand buckle bolt right-hand bolt left-hand buckle bolt right-hand bolt left-hand buckle bolt right-hand
thread thread thread thread thread thread
Product
b M12 L M12 M16 L M16 M16 L M16
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
100±10 * 50 60 40 50 60 40 - - -
120±15 50 75 40 50 75 40 - - -
140±15 50 75 60 50 75 60 80 60 50
SPV
160±15 50 95 60 50 95 60 80 75 60
180±15 50 115 60 50 115 60 80 95 60
200±15 50 135 60 50 135 60 80 115 60
HALFEN cast in channel HTA 38/17 HTA 38/17 HTA 49/30
Short pieces 150, 200 and 250
* Minus tolerance limited for load range 7.0

21
HA LF E N H O R I ZO NTA L A NCHO RING / D OW EL R ESTR AINTS
Tension and pressure resistant connection in the space between parallel surfaces

HALFEN WDK-3.0 Plastic wind anchor for push-through installation

(as constructional tension and pressure resistant connection)


Load range = ± 3.0 kN
Extension FRd = ± 4.5 kN

Ring plate
Only suitable for constructive fixations.
Threaded tube

Extension Mortar cartridge

Threaded rod,
thread M10
Plug wi- b
f
thout rim

Insert tube

Plug
with rim

Table 18 HALFEN WDK-3,0 Plastic wind anchor Selection table depending on f and b

Plug Insert tube Insert tube Extension Threaded tube Extension Threaded rod
Article with rim
description + Extension + Ring plate + Mrtar cartridge
* **
WDK-STR WDK-E-3.0-100 WDK-E-3.0-120 WDK-E-3.0-VRL20 WDK-M WDK-M-3.0-VRL40
Order No. 0250.060- 0247.010- 0247.010- 0247.010- 0247.020- 0247.020-
Typ 0430.010-
f b 00001 00001 00002 00003 00001 00004
80 60 1 1 - - 1 - 1 WDK-DUE-3.0-100- 20/ 60-A4 00014
80 80 1 1 - - 1 - 1 WDK-DUE-3.0-100- 20/ 60-A4 00014
80 100 1 1 - - 1 1 1 WDK-DUE-3.0-100- 70/100-A4 00015
80 120 1 1 - - 1 1 1 WDK-DUE-3.0-100- 70/100-A4 00015
100 60 1 1 - - 1 - 1 WDK-DUE-3.0-100- 20/ 60-A4 00014
100 80 1 1 - - 1 1 1 WDK-DUE-3.0-100- 70/100-A4 00015
100 100 1 1 - - 1 1 1 WDK-DUE-3.0-100- 70/100-A4 00015
100 120 1 1 - - 1 2 1 WDK-DUE-3.0-100-110/140-A4 00016
120 60 1 - 1 - 1 1 1 WDK-DUE-3.0-100- 70/100-A4 00015
120 80 1 - 1 - 1 1 1 WDK-DUE-3.0-100- 70/100-A4 00015
120 100 1 - 1 - 1 2 1 WDK-DUE-3.0-100-110/140-A4 00016
120 120 1 - 1 - 1 2 1 WDK-DUE-3.0-100-110/140-A4 00016
120 130 1 - 1 - 1 2 1 WDK-DUE-3.0-100-150/180-A4 00017
* alternative: Plug without rim WDK-STO, Order No. 0250.060-00002
** When using more than two extensions , additional spacer bolts (e.g. DS 13) at a separation pf approx. 15 - 30 cm be used to take up the pressure.

Installation parts: Component parts:


Threaded tube
Insert tube
Ring plate
SW27
Ø37

115
100
Extension (+40 mm)
for threaded tube

Extension (+20 mm) for 40


insert tube 20

22
HA LF E N H O R I ZO NTA L A NCHO RING / D OW EL R ESTR AINTS
Tension and pressure resistant connection in the space between parallel surfaces

HALFEN WDI Wind anchor for push-through installation

(as tension and pressure resistant connection)


Load range = ± 7.0 kN
FRd = ± 10.5 kN

The permissible pressure forces only


apply for k ≤ 200 mm. For k > 200 mm,
pressure loads must be certified.
Threaded rod
Pressure distribution plate
thread M12

b
Fixation plate f
Insert tubes k

Allen screws

Installation parts: Installation parts: Mortar set:

injection cartridge

WDI-7.0-E, Order No. 0247.030-f WDI-7.0-M, Order No. 0247.040-f-b


static mixer
consisting of: consisting of:
1x pressure distribution plate 1x fixation plate
extension tube
2x insert tube 2x allen screw
1x threaded rod

Always remember to quote the Always remember to quote the di- Injection Set, Order No. 0250.110-
dimension “f” when ordering. mensions “f” and “b” when ordering. 00006
consisting of:
injection cartridge including static
Installation accessories: Setting tool:
mixer
1x static mixer
1x extension tube 1m

(sufficient for approx. 30 drilled holes)


L = length threaded rod

WDI-Z2, L=240 Order No. 0250.110-00010 WDI-Z4, Order No. 0250.110-00011


WDI-Z2, L=330 Order No. 0250.110-00018
WDI-Z2, L=490 Order No. 0250.110-00019
Holder for the precise fixation of the
installation parts while cementing in. For installation, please refer to the
Threaded rod M14. Assembly Instructions

23
HA LF E N H O R I ZO NTA L A NCHO RING / D OW EL R ESTR AINTS
Tension and pressure resistant connection for lateral orthogonal surfaces

HALFEN HKZ restraint tie type (for tensile loads only)

20
FRd

b ar
a1
l

Product characteristics: Ordering example: HKZ-38/17-100-A4 Component parts:


The serrated grooves in the strap and • Hammer-head tie with serration
the counter-plate guarantee a statically Product • Serrated counter-plate
flawless load transmission. Three- Cavity a1
dimensional adjustability is ensured Material
through the half-channels that are con- (GV / A4)
creted in at right-angles to each other.

Order the HALFEN channels and


HALFEN head bolts separately

Table 19 HALFEN restraint tie HKZ


Characteristics: Product selection: gv = galvanized Product selection: Dimensions Dimensions
A4 = stainless steel of fixation to
grade 316 HALFEN cast-in
Load range Max. load Cavity Length Cavity Toler- Slot channel with
(tension) FD,Rd b Product a1 l ar ance HALFEN T-head
Product a1 bolt
[kN] [kN] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
0 HKZ 28/15 - 50 - gv HKZ 28/15 - 50 - A4 90
25 HKZ 28/15 - 75 - gv HKZ 28/15 - 75 - A4 115
50 HKZ 28/15 - 100 - gv HKZ 28/15 - 100 - A4 140 HTA 28/15
75 HKZ 28/15 - 125 - gv HKZ 28/15 - 125 - A4 165 HS 28/15
a1 M10x30
3.5 4.9 100 HKZ 28/15 - 150 - gv HKZ 28/15 - 150 - A4 190 50 11x55
± 20 Tightening
125 HKZ 28/15 - 175 - gv HKZ 28/15 - 175 - A4 215 torque
150 HKZ 28/15 - 200 - gv HKZ 28/15 - 200 - A4 240 MA=15Nm
175 HKZ 28/15 - 225 - gv HKZ 28/15 - 225 - A4 265
200 HKZ 28/15 - 250 - gv HKZ 28/15 - 250 - A4 290
0 HKZ 38/17 - 75 - gv HKZ 38/17 - 75 - A4 115
25 HKZ 38/17 - 100 - gv HKZ 38/17 - 100 - A4 140
50 HKZ 38/17 - 125 - gv HKZ 38/17 - 125 - A4 165
HTA 38/17
75 HKZ 38/17 - 150 - gv HKZ 38/17 - 150 - A4 190 HS 38/17
100 HKZ 38/17 - 175 - gv HKZ 38/17 - 175 - A4 215 a1 M12x50
7.0 9.8 75 13x55
125 HKZ 38/17 - 200 - gv HKZ 38/17 - 200 - A4 240 ± 20 Tightening
150 HKZ 38/17 - 225 - gv HKZ 38/17 - 225 - A4 265 torque
MA=25Nm
175 HKZ 38/17 - 250 - gv HKZ 38/17 - 250 - A4 290
200 HKZ 38/17 - 275 - gv HKZ 38/17 - 275 - A4 315
225 HKZ 38/17 - 300 - gv HKZ 38/17 - 300 - A4 340
Short pieces 150, 200, or 250 mm long or drilled bolts approved by building regulations. When using drilled bolts, check the edge distance ar.
Only limited use for facing panel anchorage!

24
HA LF E N H O R I ZO NTA L A NCHO RING / D OW EL R ESTR AINTS
Tension and pressure resistant connection for lateral orthogonal surfaces

HALFEN HKZ-GF restraint tie and HKZ-GU (for tensile and compressive loads)

HKZ-GU
FRd

b ar
a1
HKZ-GF
l

Product characteristics: Ordering example: HKZ-GU-50/30-225-A4 Component parts:


The serrated grooves in the strap and • Tie with serrations, welded-on
the counter-plate guarantee a statically Product threaded rod and pre-assembled
flawless load transmission. Cavity a1 tapped plate, nut and washer
The closure on both sides using Material • Serrated counter-plate
HALFEN T-head bolts and/or tapped (GV / A4)
plates with the use of concreted-in
HTA HALFEN channels guarantees a
non-positive and slip-free wind anchor-
age. Adjustments can be made in three Order the HALFEN channels and
directions during the installation. HALFEN head bolts separately

Tabelle 20 HALFEN Verankerungslasche HKZ-GF und HKZ-GU


Characteristics: Product selection: gv = galvanized Product selection: Dimensions Dimensions
A4 = stainless steel of fixation to
grade 316 HALFEN cast-in
Load range Max. load Cavity Length Cavity Toler- Slot channel with
Product a1 HALFEN T-head
(tension) FD,Rd b Product a1 l ar ance
bolt
[kN] [kN] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
25 HKZ - GF 28/15 - 75 - gv HKZ - GF 28/15 - 75 - A4 115 HTA 28/15
50 HKZ - GF 28/15 - 100 - gv HKZ - GF 28/15 - 100 - A4 140 HS 28/15
a1 M10x30
± 3.5 ± 4.9 75 HKZ - GF 28/15 - 125 - gv HKZ - GF 28/15 - 125 - A4 165 50 11x55
± 20 Tightening
100 HKZ - GF 28/15 - 150 - gv HKZ - GF 28/15 - 150 - A4 190 torque
125 HKZ - GF 28/15 - 175 - gv HKZ - GF 28/15 - 175 - A4 215 MA=15Nm
25 HKZ - GF 38/17 - 100 - gv HKZ - GF 38/17 - 100 - A4 143
50 HKZ - GF 38/17 - 125 - gv HKZ - GF 38/17 - 125 - A4 168 a1 HTA 38/17
75 13x55 HS 38/17
75 HKZ - GF 38/17 - 150 - gv HKZ - GF 38/17 - 150 - A4 193 ± 20
M12x50
± 7.0 ± 9.8 100 HKZ - GF 38/17 - 175 - gv HKZ - GF 38/17 - 175 - A4 218 Tightening
125 HKZ - GU 38/17 - 200 - gv HKZ - GU 38/17 - 200 - A4 243 torque
a1
150 HKZ - GU 38/17 - 225 - gv HKZ - GU 38/17 - 225 - A4 268 75 13x60 MA=25Nm
± 20
175 HKZ - GU 38/17 - 250 - gv HKZ - GU 38/17 - 250 - A4 293
50 HKZ - GU 50/30 - 200 - gv HKZ - GU 50/30 - 200 - A4 240 HTA 49/30
75 HKZ - GU 50/30 - 225 - gv HKZ - GU 50/30 - 225 - A4 265 HS 50/30
a1 M16x50
± 12.0 ± 16.8 100 HKZ - GU 50/30 - 250 - gv HKZ - GU 50/30 - 250 - A4 290 150 17x60
± 20 Tightening
125 HKZ - GU 50/30 - 275 - gv HKZ - GU 50/30 - 275 - A4 315 torque
150 HKZ - GU 50/30 - 300 - gv HKZ - GU 50/30 - 300 - A4 340 MA=60Nm

Short pieces 150, 200, or 250 mm long or drilled bolts approved by building regulations. When using drilled bolts, check the edge distance ar.
Only limited use for facing panel anchorage!

25
HA LF E N H O R I ZO NTA L A NCHO RING / D OW EL R ESTR AINTS
HALFEN dowel restraint fitting (upper and lower parts)

Slotted (oval) socket H F V Slotted steel socket HFV 2 Grouting socket HFV 4
1

L
230

230
L

L
6

60
44/47
Remove the
polystyrene be-

90

B
60
B

B
fore positioning
the dowel, and
120 fill the socket
60
with mortar
Material: plastic Material: stainless steel A4 Material: stainless steel A4

Plastic socket HFV 5 Fixed dowel HFV 7 Plastic socket HFV 8

6 48
60

230
L

L
L

230

B B
6 48
75
45

45
50

Material: plastic Material: stainless steel A4 Material: stainless steel A4

Grouting socket HFV 9 Loose dowel HFV 3 Spiral reinforcement Type HFV B
B zu HFV 1, HFV 5 und HVF 9
Ø40x100

32/60x120
L

Spiral reinforcement 60 x 80 mm
D Order No.
Product
0249.100-
HFV-B-WB 00001
Fill with mortar after positioning the dowel.
Material: plastic Material: stainless steel A4 HFV-B-A4 00002

Table 21 HALFEN dowel restraint fitting Up to a grouting depth of 20 mm and a minimum plate thickness of 80 mm
Upper parts and lower parts Dowel
Product
HFV 1 HFV 2 HFV 4 HFV 5 HFV 7 HFV 8 HFV 9 HFV 3
40x100 32/60x120
Load range
[kN] B L B L B L B L D L B L B L B L D L
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
2.5 18 100 17 50 44 100 16.5 100 16 150 17 100 16 150
40 100 32/60 120
5.0 22 100 21 60 44 100 20.5 100 20 150 21 100 20 150

26
HA LF E N H O R I ZO NTA L A NCHO RING / D OW EL R ESTR AINTS
Possible combinations of the HALFEN dowel restraint fitting

Dowel HALFEN dowel restraint fitting – upper parts


HFV 3 HFV 1 HFV 2 HFV 5 HFV 8

HFV 4

HFV 5

e.g. Combination
Upper part HFV 8
Dowel HFV 3
Lower part HFV 4
HALFEN dowel restraint fitting – lower parts

HFV 7

Combina-
tion with-
out HFV 3
HFV 8
Ordering example: HFV - 8 3 4 - 2.5
Restraint
Upper part, type
Dowel, type
Lower part, type
Load range

HFV 9

27
HA LF E N P A R A PE T CO RBE LS
New parapet corbel from 2006

BRA-N, Standard version


ed
ov
pr
-ap

Standard parapet corbel without height parapet corbel using a HALFEN cast-in
pe
Ty

(vertical) adjustment bolt. channel or an approved anchor bolt.


Types: BRA-1 to BRA-8. This product is used, for example, to
Larger special profiles are possible. fix balcony units. In doing this, the
The adjustment of the height is only parapet corbel should be installed deep
possible to a limited extent. To do this, in the floor slab. Only install 2 parapet
additional steel shims are required, corbels per parapet unit; an adjustable
which are placed underneath at the version is strongly recommended for
front thrust bearing. Fixation of the more corbels.

BRA-A, Spandrel version


ed
ov
pr
-ap

Spandrel version parapet corbel with- parapet corbel using a HALFEN cast-in
pe
Ty

out height (vertical) adjustment bolt channel or an approved anchor bolt.


Types: BRA-1 to BRA-8. This product is used, for example, for
Larger special profiles are possible. spandrel elements in the roof area.
The adjustment of the height is only Only install 2 parapet corbels per
possible to a limited extent. To do this, spandrel element, an adjustable ver-
additional steel shims are required, sion is strongly recommended for more
which are placed underneath at the corbels.
front thrust bearing. Fixation of the

BRA-NJ, Standard version, adjustable


ed
ov
pr
-ap

Standard parapet corbel with height The adjusting unit BRA-M2 is necessary
pe
Ty

adjustment screw. for height (vertical) adjustment using


Types: BRA-1 to BRA-8. the adjusting bolt.
Larger special profiles are possible.
Fixation of the parapet corbel using a
HALFEN cast-in channel or an ap-
proved anchor bolt.

Parapet corbel, Spandrel version, adjustable


ed
ov
pr
-ap

Types: BRA-1 to BRA-8. The adjusting unit BRA-M2 is necessary


pe
Ty

Larger special profiles are possible. for height (vertical) adjustment using
Fixation of the parapet corbel using a the adjusting bolt.
HALFEN cast-in channel or an appro-
ved anchor bolt.

28
HA LF E N P A R A PE T CO RBE LS

Installation of the parapet corbel

BRA-N BRA-NJ
Standard model Standard model
without height with height
ds
ds adjustment bolt
adjustment bolt i
i
≥25 ≥35
≥25 ≥35
LL
LL

h
h

min f min f

65 50 b te 65 50 b te
L L

Table 22 BRA - Dimensions / Standard lengths L in mm Parapet slab thickness / Reinforcement


Preferenced profile length L for Cavity Embedded
Profile height Slot Slab thickness Rod Cavity
Type depth
0 - 40 60 - 100 120 - 140 h LL min f ds i
te
BRA 1 400 450 500 44 17 x 80 70 100 Ø 10 40
BRA 2 450 500 550 48 19 x 80 72 100 Ø 10 40
BRA 3 500 550 600 54 19 x 80 82 110 Ø 12 50
BRA 4 550 600 650 66 21 x 80 92 120 Ø 14 60
BRA 5 550 600 650 70 24 x 80 102 130 Ø 14 70
BRA 6 600 650 700 83 24 x 80 108 135 Ø 16 75
BRA 7 650 700 750 84 24 x 80 123 150 Ø 16 90
BRA 8 700 750 800 85 24 x 80 125 150 Ø 20 90
Material stainless steel A4

BRA Assembly accessories:


Order BRA-M1 separately Order BRA-M2 separately
Assembly parts for HALFEN para- Height adjustment for HALFEN
pet corbel parapet corbel BRA-NJ/-AJ

Complete set: Complete set:


Matrix plate, 2 shims Hexagonal bolt,
for level equalization, locking plate, 1 or 2
t = 3 and shims for level equaliza-
t = 6 mm tion, t = 6 mm

Table 23 BRA - Assembly accessories M1 depending on the profile Table 24 BRA - Assembly accessories M2 depending on the profile
Assembly kit 1 recommended HALFEN spacer bolt, Assembly kit 2 Dimensions supplied
order separately Hexagonal bolt Footplate washers
BRA - M1 - 1 HS 40/22 M12 x 80 BRA - M2 - 1 M16 x 60 40x40x 6
BRA - M1 - 2 HS 50/30 M16 x 80 BRA - M2 - 2 M16 x 60 40x40x 6
1 pcs
BRA - M1 - 3 HS 50/30 M16 x 80 BRA - M2 - 3 M20 x 60 40x40x 7
BRA - M1 - 4 HS 50/30 M16 x 80 BRA - M2 - 4 M24 x 80 40x40x 7
BRA - M1 - 5 HS 50/30 M20 x 75 BRA - M2 - 5 M27 x 80 60x60x10
BRA - M1 - 6 HS 50/30 M20 x 75 BRA - M2 - 6 M27 x 80 60x60x10
2 pcs
BRA - M1 - 7 HS 50/30 M20 x 75 BRA - M2 - 7 M30 x 80 70x70x12
BRA - M1 - 8 HS 50/30 M20 x 75 BRA - M2 - 8 M30 x 80 70x70x12
Material stainless steel A4 or galvanized Material stainless steel A4 or galvanized

29
HA LF E N U N I V E RS AL TIE S

HALFEN ULZ universal ties


06
20

Ordering example: ULZ-40-6-200

t
W
NE

Product
L Width c
f Thickness t
Length L

c
Table 26 HALFEN ULZ universal tie with serrations
L c t f Slot Matrix plate Max. load on positio-
Product ning FRd [kN]
[mm] [mm] [mm] [mm] [mm]
183 30 5
233 30 5
40 55/11 25/25/4 Ø11 4.9
283 30 5
333 30 5
200 40 6
240 40 6
280 40 6 45 55/13 30/30/5 Ø13 9.8
ULZ 320 40 6
450 40 6
240 60 6
320 60 6 40 60/17 35/40/5 Ø17 16.8
450 60 6
240 80 8
320 80 8 45 60/17 35/40/5 Ø17 16.8
450 80 8
• other dimensions on request • Material stainless steel A4
Max. load of the tie dependent on the bending shape

Delivery options for the ULZ universal tie - on request

Flat L-angle

U-angle Z-angle

Factory machining, please quote dimensions when ordering (sketch)

30
SO F TWA R E

HALFEN offers the planner an ideal tool with its dimensioning programs.

The HALFEN dimensioning programs BRA and FPA are user-friendly and easy to operate. The calculation takes place after the
entry of the dimensions of the facing or parapet slab, the selection of the anchor types and some options.

As an alternative, the dimen-


sions can also be entered via
a ViewEdit window.

BRA calculation result FPA calculation result

• Description of the parapet corbel profile • Description of the calculated anchorage type
• Loads per profile • Loads per anchor
• Recommendation for fixations to be used • Designation of the spacer bolts or of the dowel
• Output of the results with a drawing restraint fitting
• Output of the static verification • Loads for horizontal restraints
• Suction protection where required
• Output of the results with a drawing

It works without saying that both the FPA program and the You can obtain our program by
BRA program – as well as the other HALFEN software – are download from the Internet under
equipped with a simple-to-operate Help function. www.HALFEN-deha.de/Download
or on our latest Dimensioning
Software CD, which you can order
free of charge.

31
B A S I C S TA T I C CA LCULA TIO NS
HALFEN Façade Panel Anchor

HALFEN façade panel anchors

Dimensioning of the anchor forces:


G = Vertical weight from proportional dead weight of the slab
With symmetrical suspension, G per anchor is = ½ dead weight of the slab
V R
W = Wind load per horizontal anchor (¼ of the wind load on the slab)
In the case of different overhangs of the supports or in case of peak suction, the
horizontal loads must be calculated more accurately.
wd = 1.25 x cp x q x prop. A Do
ws = 1.1 x cp x q x prop. A
α h2

According to expertise, global safety of 1.2 against lifting off H

Partial safety correction values for the influences:


γG = 1.35 constant influence (dead load) W
h
γQ = 1.50 variable influence (wind load) h1

Anchor forces: G
Vd = Vertical force in the anchor = G x γG e
Hd = Horizontal force in the anchor = Vd x tan α
Rd = Resulting diagonal load in the anchor = Root (Vd2 + Hd2) Du

Dod = Horizontal force at top (from Dog,d + Dow,d)


Dud = Horizontal force at base (from Dug,d + Duw,d) f b

Dog,d = Horizontal force at top from dead weight x γG


max Dow,d = Horizontal force at top from wind (wd x γQ)
min Dow,d = Horizontal force at top from wind (ws x γQ)
Dug,d = Horizontal force at base from dead weight x γG h1
max Duw,d = Horizontal force at base from wind (wd x γQ) Du
min Duw,d = Horizontal force at base from wind (ws x γQ)

Condition:
If min Dod < 0 → Suction protection necessary (e.g. adjustable restraint) α = Angle of inclination
If min Dud < 0 → Suction protection necessary (e.g. adjustable restraint) (See Tables 3 to 5)

Berechnung:
ΣMA → Dug,d = ( Hd x h2 + Vd x e ) / h1
max Dud = Dug,d + max Duwd
min Dud = Dug,d – min Duw,d

ΣH → Dog,d = Hd – Dug,d
max Dod = Dog,d + max Dowd
min Dod = Dog,d – min Dow,d

32
B A S I C S TA T I C CA LCULA TIO NS
HALFEN parapet corbel

Influences, Partial safety correction factors Static systems

Influences:
G = Dead weight H
V1 = Vertical load (flower pot) V
Hd = Horizontal load (railing load)
a1
W = Wind load

h1
Partial security correction values for the influences:
γG = 1.35

h/2
(dead load) L
γQ = 1.5 (life loads) Z te

My
W
Mi

ew
Dimensioning (see also product statics)
WV
1. D

h/2
Z
2.
G
3. from dead weight

from vertical load (flower pot)


65 y 50 b f

from horizontal load (railing load)

from wind

4. Thrust
bearing

5. Vertical displacement

Please use our Dimensioning Software for the


selection of the correct type of anchor and the
static verification.

Table 27 Fixation
Fixation BRA 1 BRA 2 BRA 3 BRA 4 BRA 5 BRA 6 BRA 7 BRA 8
HALFEN cast-in
40/25 49/30 49/30 49/30 54/33 54/33 54/33 54/33
channel HTA
HTA - Fz,Rd [kN] 11.2 16.8 16.8 16.8 30.8 30.8 30.8 30.8
HALFEN spacer
M12 M16 M16 M16 M20 M20 M20 M20
bolt HS
HS - Fz,Rd [kN] 13 24.2 24.2 24.2 37.8 37.8 37.8 37.8

Table 28 Maximum load


Max. load BRA 1 BRA 2 BRA 3 BRA 4 BRA 5 BRA 6 BRA 7 BRA 8
Mpl,y,d [kNcm] 203 244 420 631 879 1204 1529 2106
Mpl,z,d [kNcm] 185 228 398 599 816 1086 1437 2034
Npl,d [kN] 137 148 231 279 374 427 540 769
Vpl,z,d [kN] 44 46 73 86 119 136 170 246

33
HA LF E N F R ONT PANE L (F AÇADE ) FIX ATIONS

The façade of a building is the visible Concrete, cast stone- and natural stone façades
structural envelope and thereby the visit-
ing card of the company. In addition to
the aesthetic requirements on the façade,
HALFEN grout-in anchors
the latter also has, above all, very practi- An inexpensive and alternative fixation op-
cal functions to fulfill. It is primarily used tion for natural stone and cast stone slabs is
as a protection against damp, rain, heat offered by the grout-in anchor.
This fixation is suitable for both high loads
and noise. and large cantilevers. The round shape
has the advantage of not changing the
In conjunction with the architectural load-bearing capacities, even in the case of
possible misalignment along the tube axis.
requirements on the façade material and
the type of façade, rear-ventilated designs Please refer to our catalog for more infor-
in particular have proved their value with mation: HALFEN FS Natural Stone Anchors
regard to long service life for brickwork,
natural stone and concrete and cast
stone façades. The care that the architect
invests in the drafting and the design of
the outer envelope is just as necessary
for the planning of the non-visible sub-
structure.

This applies in an exemplary manner to HALFEN FM Body Anchor


The most effective way to mount thin
the curtain-type, rear-ventilated façades.
natural or cast stone slabs in front of a
The advantages are particularly large supporting concrete construction. The
here. The sound insulation factor and combination with grouted-in HALFEN
channels in particular makes a fast installa-
the heat protection, for example, can be
tion possible. Different products economi-
considerably improved. cally cover all the necessary requirements
The latter is particularly important with on loading and cantilevers.
regard to the continuously increasing
Please refer to our catalog for more infor-
requirements on energy and affects the mation: HALFEN FS Natural Stone Anchors
protection of heat in both the winter
and the summer periods. Large insula-
tion factors can be realized in the cavities
without problem.

HALFEN offers the appropriate sub-struc-


ture and façade fixation for all require-
ments. Our decades of experience and
our claims for safety, quality and long
service life have been vindicated.
Fixation for brickwork support systems
Rely on proven safety, in particular Large area rocks, slabs and brickwork can
also be supported with brickwork support
where you want to mount high quality systems. The brickwork support is avail-
façade facings whose service life should able in countless models and cantilever
correspond to that of the outer envelope. dimensions for all requirements.
Inaccessible façade cavities require a high
Please refer to our catalog for more infor-
quality standard. And this is the proven mation: HALFEN FM Brickwork Support
safety that HALFEN offers you. Systems

34
HA LF E N F R ONT PANE L (F AÇADE ) FIX ATIONS

Concrete, cast stone- and natural stone façades

HALFEN Substructure System


This construction for rear ventilated and
curtain wall façades made from thin natu-
ral stone slabs or cast stone is particularly
suitable for large cavities with large insula-
tion thicknesses and irregular cavities.

Please refer to our catalog for more infor-


mation: HALFEN FS Natural Stone Anchors

MVA Sleeve Sandwich Panel Anchor


The sleeve sandwich panel anchors for reinforced
concrete façade elements connect the facing
layer to the insulation and load-bearing layer.
The system is particularly suitable for large-area
slabs with a high insulation thickness.

Please refer to our catalog for more information:


DEHA MVA Sleeve Sandwich Panel Anchor

SPA Sandwich Panel Anchor


Sandwich panels combine the supporting cha-
racteristics of a concrete wall with the functional
and design elements of facing wall constructions,
linked by the type-tested HALFEN sandwich an-
chor. The insulation layer core is only penetrated
by a thin anchor.

Please refer to our catalog for more information:


HALFEN SPA Sandwich Panel Anchor

35
C ON TA C T H A L F E N WO RLDWIDE
HALFEN is represented with subsidiaries in the following 14 countries, please contact us:

Austria HALFEN Gesellschaft m.b.H. Phone: +43 - 1 - 259 6770 Fax: +43 - 1 - 259 - 6770 99
Leonard-Bernstein-Str. 10 E-Mail: office@halfen.at
1220 Wien Internet: www.halfen.at
Belgium/Luxembourg HALFEN-FRIMEDA N.V. Phone: +32 - 3 - 658 07 20 Fax: +32 - 3 - 658 15 33
Borkelstraat 131 E-Mail: info@halfen.be
2900 Schoten Internet: www.halfen.be
China HALFEN Construction Accessories Distribution Co.Ltd. Phone: +86 - 10 5861 4009 Fax: +86 - 10 5861 4012
Room 2112 Tower B, U-Space E-Mail: info@halfen.com
No. 8 Guang Qu Men Wai Street Internet: www.halfen.cn
Chao Yang District
Beijing · P.R. China 100022
Czechia HALFEN-DEHA s.r.o. Phone: +420 - 311 - 672 612 Fax: +420 - 311 - 671 417
K Vypichu 986 · Komercni zóna Rudná, hala 6 E-Mail: info@halfen.cz
25219 Rudná Internet: www.halfen.cz
France HALFEN S.A.S. Phone: +33 - 1 - 445231 00 Fax: +33 - 1 - 445231 52
18, rue Goubet E-Mail: halfen@halfen.fr
75019 Paris Internet: www.halfen.fr
Germany HALFEN-DEHA Vertriebsgesellschaft mbH Phone: +49 - 2173 - 970 0 Fax: +49 - 2173 - 970 225
Katzbergstraße 3 E-Mail: info@halfen.de
40764 Langenfeld Internet: www.halfen.de
Italy HALFEN-DEHA S.r.l. Soc. Unipersonale Phone: +39 - 035 - 0760711 Fax: +39 - 035 - 0760799
Via F.lli Bronzetti N° 28 E-Mail: info@halfen.it

applies also to copying in extracts.


© 2008 Halfen GmbH, Germany
24124 Bergamo Internet: www.halfen.it
Netherlands HALFEN b.v. Phone: +31 - 547 - 3830 30 Fax: +31 - 547 - 3830 35
Vonderweg 5 E-Mail: info@halfen.nl
7468 DC Enter Internet: www.halfen.nl
Norway HALFEN-FRIMEDA AS Phone: +47 - 51 82 34 00 Fax: +47 - 51 82 34 01
Postboks 2080 E-Mail: post@halfen.no
4095 Stavanger Internet: www.halfen.no
Poland HALFEN Sp. z o.o. Phone: +48 - 61 - 842 56 00 Fax: +48 - 61 - 842 56 01
Ul. Obornicka 287 E-Mail: info@halfen.pl
60-691 Poznan Internet: www.halfen.pl
Spain HALFEN-DEHA S.L. Phone: +34 - 91 - 632 18 40 Fax: +34 - 91 - 633 42 57
c/ Fuente de la Mora 2, 2° D E-Mail: info@halfen.es
28050 Madrid Internet: www.halfen.es
Sweden HALFEN AB Phone: +46 - 31 - 98 58 00 Fax: +46 - 31 - 98 58 01
Box 150 E-Mail: info@halfen.se
435 23 Mölnlycke Internet: www.halfen.se
Switzerland HALFEN Swiss AG Phone: +41 - 44 - 849 78 78 Fax: +41 - 44 - 849 78 79
Industriestrasse 32 E-Mail: mail@halfen.ch
8108 Dällikon Internet: www.halfen.ch
1.000 03/08

United Kingdom / HALFEN Ltd. Phone: +44 - 1582 - 47 03 00 Fax: +44 - 1582 - 47 03 04
Ireland Humphrys Road · Woodside Estate E-Mail: info@halfen.co.uk
Dunstable LU5 4TP Internet: www.halfen.co.uk

Furthermore HALFEN is represented with sales offices and distributors worldwide. Please contact us: www.halfen.com
F - 030 - E - 03/08

NOTES REGARDING THIS CATALOGUE


Technical and design changes reserved. The information in this publication is based on state-of-the-art technology at the time of publi-
cation. We reserve the right to make technical and design changes at any time. Halfen GmbH shall not accept liability for the accuracy of
the information in this publication or for any printing errors.

The Quality Management System of Halfen GmbH is certified for the locations in Germany, Switzerland and Poland according to DIN EN
ISO 9001:2000, Certificate No. QS-281 HH.

S-ar putea să vă placă și