Objective: Recommend quantity and size of aerators required for 2 basin activated sludge
process. Note that the oxygen demand from COD is greater than for BOD.
Design Data:
Wastewater Parameters
3
Average Flow = 4,001 m /day
o
Temperature = 30 C (summer, assumed)
o
= 20 C (winter, assumed)
Influent COD = 1000 mg/l
Influent TKN = 100 mg/l
Scope:
Recommend quantity and size of aerators required for 2 basin activated
sludge process.
Calculations:
Power Requirement
Power (aeration) = 243.25 kg/hr
1.04 kg/BHP-hr x 0.92
= 254.2 kW = 340.9 HP
= 127.1 kW / Basin = 170.5 HP / Basin
Recommendation:
Recommend using three (3) - 60 HP (44.7 kW) Aqua-Jet aerators in each of
two basins for a total of six (6) - 60 HP aerators.
DRH