Multilin™ F60

Advanced Protection, Control & Automation Protection & Control


for Distribution Feeders • High-impedance fault detection (downed
conductor detection)
The Multilin F60 Feeder Protection System provides feeder protection, control, monitoring and metering
• Thermal overload, incipient cable fault and
in an integrated, economical, and compact package.
broken conductor detection
The F60 incorporates a unique and matured algorithm to detect high-impedance faults, such as downed • Four-shot autorecloser, VT fuse failure
conductor detection. It also provides fast and deterministic execution of programmable logic, which is detection, and synchronism check
necessary for substation automation applications. Graphical programming tools (Viewpoint Engineer),
supported by a library of logic components, make the F60 simple to use and configure.
Communications
Key Benefits • 3 independent Ethernet ports for simultaneous
& dedicated network connections with
• Advanced and flexible protection and control for distribution feeder applications with unique and
IEEE 1588 support
secure downed conductor detection backed by many years of field experience
• Supported industry protocols: IEC 61850 Ed. 2,
• Flexible load encroachment allows secure operation during heavy load conditions
SFTP, MMS File Transfer Service, DNP 3.0,
• Voltage and frequency elements provide load shedding & transfer schemes for increased system Modbus Serial/TCP, IEEE 1588, IEC 60870-5-104
uptime and stability and 103, PRP, SNTP, HTTP, TFTP
• Embedded Synchrophasor measurement capabilities (per IEEE® C37.118), eliminating the need for • Direct I/O for secure, high-speed exchange
dedicated PMUs and support for synchrophasor multi-cast (per IEC® 61850-90-5) reducing bandwidth of data between URs for DTT & pilot-aided
and communications infrastructure costs schemes
• Advanced IEC 61850 Ed. 2 implementation, complete settings via SCL files and IEC 61850-9-2 process
bus solution enable resource and platform managing optimization and reduce cost of ownership
• Increased network availability via failover time reduced to zero through IEC® 62439-3 “PRP” support
Cyber Security
• CyberSentry™ provides high-end cyber
• CyberSentry™ provides high-end cyber security aligned to industry standards and services (NERC® CIP,
security aligned to industry standards and
AAA, Radius, RBAC, Syslog)
services (NERC® CIP, AAA, Radius, RBAC, Syslog)
• Advanced fault and disturbance recording, including internal relay operating signals, eliminating the
• Setting for security audit trails, tracking
need for external recording devices
changes to device configurations

Applications
• Primary protection and control for feeders on solidly, impedance or resonant (Petersen coil) grounded
Monitoring & Metering
systems • P&M class synchrophasors of voltage, current,
• Busblocking / interlocking schemes and sequence components

• Distribution load shedding schemes based on voltage and frequency elements • Advanced recording capabilities with high-
capacity event recorder, configurable and
• High-speed fault detection for arc flash mitigation extended waveform capture and data logger
• Throw over schemes (bus transfer scheme applications) • Metering: current, voltage, power, energy,
• Backup protection for transmission lines, feeders and transformers frequency, and harmonics
• Distributed Generation (DG) interconnect protection , including active and passive anti-islanding
F60 Feeder Protection System

Protection and Control F60 - Protection, Metering, Monitoring and Control


As part of the Universal Relay (UR) family, the
F60 features high-performance protection,
expandable I/O options, integrated monitoring
and metering, high-speed communications,
and extensive programming and configuration
capabilities including:

Downed Conductor (Hi-Z) Detection


Fires, injuries, and even fatalities may be caused
by a live downed conductor. Unfortunately,
these high risk incidences often go undetected
by conventional protective relays.

The Hi-Z element in the F60, unique to Multilin,


provides reliable detection of faults caused by
downed conductors. Sophisticated algorithms
developed over the past 20 years, detect
downed conductors, tree branch contacts, and
insulation fault in underground cables. This The F60 offers an integrated protection, control, metering and monitoring package that can directly
unique, field-proven algorithm incorporates connect into DCS or SCADA monitoring control systems, such as Viewpoint Monitoring.
artificial intelligence to maximize dependability.
Key benefits of Hi-Z detection in the F60:

Functional Block Diagram

52

79(4)
2 CLOSE TRIP 81U
Monitoring 6

81O
50P 50_2 51_2 50BF 51P/V 67P 67_2 32 49 50N 51N 67N/G 50NBF 4
4 2 2 2 4 2 2 2 2 4 4 2 2
27P
3

Transducer 59P
FlexElement™ METERING Inputs
3

87G 50G 51G 59N


3
4 4

27X 59X 59_2


2 2 3
25
F60 Feeder Protection System 4

ANSI® Device Numbers & Functions


DEVICE DEVICE DEVICE
FUNCTION FUNCTION FUNCTION
NUMBER NUMBER NUMBER
25 (2) Synchrocheck 50_2 (2) Negative Sequence Instantaneous 59X Auxiliary Overvoltage
27P Phase Undervoltage 51G (2) Overcurrent 59_2 Negative Sequence Overvoltage
27X Auxiliary Undervoltage 51N (2) Ground Time Overcurrent 67N (2) Neutral Directional Overcurrent
32 Sensitive Directional Power 51N (2) Neutral Time Overcurrent 67P (2) Phase Directional
50BF/50BNF(2) Breaker Failure 51P (2) Phase Time Overcurrent 67_2 (2) Negative Sequence Directional Overcurrent
50DD Disturbance Detector 51_2 (2) Negative Sequence Time Overcurrent 79 Automatic Recloser
50G (2) Ground Instantaneous Overcurrent 52 AC Circuit Breaker 81O (4) Overfrequency
50N (2) Neutral Instantaneous Overcurrent 59N Neutral Overvoltage 81U (6) Underfrequency
50P (2) Phase Instantaneous Overcurrent 59P Phase Overvoltage 87G(RFG) Restricted Ground Fault

2 GEDigitalEnergy.com
F60 Feeder Protection System

Auto-Transfer Scheme Implementation Example It allows the phase overcurrent elements to be


set to see end-of-line phase faults in heavily
loaded feeder applications.

FIBER/COPPER Over/Under Voltage Protection


CB1 CB2 The F60 includes the following voltage elements:
F60-1 F60-2

• Up to 2 phase undervoltage and 3 phase


overvoltage elements
• 1 auxiliary under/over voltage element
• 1 neutral overvoltage element
The following are some of the key applications
where voltage elements can be used:
TCB1
• Source transfer schemes
CB3 CB4 CB5 CB6
• Load shedding schemes
• Backup capacitor bank protection and
control
• Backup motor protection to prevent
Auto-transfer schemes can be implemented using programmable FlexLogic. Wiring between relays automatic restart
can be eliminated using peer-to-peer communication.
Abnormal Frequency Protection
The F60 offers over and underfrequency
• Reliable detection of faults caused by The F60 allows the use of directional elements
elements to improve network (grid) stability
downed conductors for supervision of ground overcurrent protection
using voltage or frequency-based load
• Fast response to hazardous situations elements and provide sensitive tripping for
shedding techniques. The F60 can be integrated
faults in one direction. Typical application for
• Dependable and secure operation using into a communications network containing
directional overcurrent includes:
artificial intelligence N60 network stability relays to implement
• Detection of arcing faults • Isolation of faulted feeders in ring bus or wide area, intelligent load shedding schemes.
parallel feeder arrangements It also provides backup protection when
• Easy integration by the addition of a Hi-Z
• Prevention of back-feeding utility source fault protecting feeders and other frequency-
module to a new or existing F60 relay
from industrial plant generators sensitive power equipment.
Directional Overcurrent Protection • Sensitive high-speed ground fault protection
Frequency Rate of Change Protection
The F60 also has built-in standard IEEE, IEC, IAC for transformers
and FlexCurves™ overcurrent characteristics Frequency rate of change (df/dt) elements are
For neutral directional sensing, the residual
(TOC), most commonly used for primary and included in the F60 to provide protection against
current of the phase CTs is used as the operating
backup protection in various protective zones. It system disturbances through load shedding
current . For current polarization, a residual
has phase IOC elements with separate outputs and to provide anti-islanding protection for
CT is used to measure zero-sequence current.
for each phase. Each TOC element has the distributed generator interconnections.
For voltage polarization, the calculated or
following programmable characteristics: measured zero-sequence voltage can be used.
Cold Load Pickup
• Pickup current level for trip, alarm, or control The maximum torque angle is programmable.
Two enhanced dual polarization modes use A cold load condition can be caused by a
• Choice of 17 curve shapes (including prolonged outage of the load, by opening the
both current and voltage signals to determine
FlexCurves) and curve multipliers circuit breaker, or by a loss of supply even if the
polarity. “Dual-V” polarization gives priority to
• Instantaneous or linear reset time polarity determined based on voltage while breaker remains closed (cyclic loads like HVAC,
characteristic to coordinate with upstream “Dual-I” polarization gives priority to polarity refrigeration systems). F60 can automatically
transformer damage curves and downstream determined based on current. detect conditions that would lead to cold load
reclosers and fuses pickup and selectively block protection elements
• Voltage restraint to increase sensitivity Load Encroachment for security during feeder energization.

The majority of distribution systems are either The load encroachment function in the F60
Wattmetric Ground Fault Protection
solidly grounded or grounded through a low provides the capability to manage load growth
impedance. Fast fault clearance is required in feeders. The load encroachment element can A sensitive wattmetric zero-sequence directional
due to the ground fault impact. The following be set for the feeder’s expected maximum load, function can be used on isolated or resonant
functions are incorporated in the F60 to provide reducing the likelihood of false tripping for load (Petersen coil) grounded, low-resistance
secure ground protection: conditions while maintaining dependability to grounded and solidly grounded systems to
trip for legitimate faults. detect ground faults.
• Neutral IOC and TOC
• Ground IOC and TOC

GEDigitalEnergy.com 3
F60 Feeder Protection System

This function determines the presence and The Multilin HardFiber System offers the Monitoring and Metering
direction of ground faults by measuring the following benefits:
The F60 includes high accuracy metering and
value and direction of zero-sequence power.
• Communicates using open standard recording for all AC signals. Voltage, current,
This flexible element responds to power derived
IEC 61850 messaging and power metering are built into the relay
from zero-sequence voltage and current in a
• Drastically reduces P&C design, installation as a standard feature. Current and voltage
direction specified by the element characteristic
and testing labor by eliminating individual parameters are available as total RMS
angle. Power can be selected as active, reactive,
copper terminations magnitude, and as fundamental frequency
or apparent . Therefore, the element may
• Integrates with existing F60’s by replacing magnitude and angle. The F60 also measures
be used to sense either forward or reverse
traditional CT/VT inputs with the IEC 61850 up to the 25th harmonic on voltage and current,
ground faults.
Process Bus module suitable for power quality applications.
Autorecloser • Does not introduce new cyber security
Fault and Disturbance Recording
Two autoreclose elements are provided for use concerns
The advanced disturbance and event recording
with distribution lines in three-pole tripping Visit the HardFiber System product page on the
features within the F60 can significantly reduce
schemes with up to two breakers. Up to four GE Digital Energy web site for more details.
the time needed for postmortem analysis of
selectable recloser “shots” are possible prior to
power system events and creation of regulatory
locking out. Any of the autoreclose elements
can be dynamically blocked or unblocked by
Advanced Automation reports. Recording functions include:

other elements or user logic. This way they can The F60 incorporates advanced automation • Sequence of Event (SOE)
coordinate with the F60 protection setting groups. features including powerful FlexLogic - 1024 time stamped events
programmable logic, communication, and • Oscillography
Synchronism Check SCADA capabilities that far surpass what is found - 64 digital & up to 40 analog channels
The F60 provides four synchrocheck elements in the average feeder relay. The F60 integrates - Events with up to 45s length
that monitor voltage difference, phase angle seamlessly with other UR relays for complete
• Data Logger and Disturbance Recording
difference and slip frequency to ensure proper system protection, including the unit and auxiliary
- 16 channels up to 1 sample/cycle/channel
breaker closure as per user requirements. Any transformers, and balance of plant protection.
• Fault Reports
of the four synchrocheck elements can be
FlexLogic - Powerful summary report of pre-fault and
dynamically blocked or unblocked by other
fault values
elements or user logic. This way they can FlexLogic is the powerful UR-platform
programming logic engine that provides the • Extensive breaker info (continuous coil
coordinate with the F60 protection setting groups.
ability to create customized protection and monitor, arcing current, operating time,
Breaker Failure and Control operation counter for asset management)
control schemes, minimizing the need and
The F60 provides the required elements to associated costs of auxiliary components The very high sampling rates and large amount
and wiring. Using FlexLogic, the F60 can be of storage space available for data recording
perform two independent breaker failure
programmed to provide the required tripping in the F60 can eliminate the need for installing
functions. The F60 can provide independent
logic along with custom scheme logic for costly stand-alone recording equipment.
breaker failure protection for both breakers
on a feeder with a breaker-and-a-half or ring auto transfer schemes (main-tie-main), load
shedding based on frequency, voltage and Advanced Device Health Diagnostics
bus terminal. The relay also provides for the
control of one or two breakers from faceplate communication, loop restoration schemes, The F60 performs comprehensive device health
pushbuttons, remote communications or other remedial action schemes and dynamic diagnostic tests at startup and continuously
contact inputs. A breaker position can be setting group changes. during run-time to test its own major functions
indicated by LEDs on the faceplate. and critical hardware. These diagnostic tests
Scalable Hardware monitor for conditions that could impact security
The F60 is available with a multitude of I/O and availability of protection, and present device
IEC 61850 Process Bus configurations to suit the most demanding status via SCADA communications and front
The IEC 61850 Process Bus module is designed application needs. The expandable modular panel display. Providing continuous monitoring
to interface with the Multilin HardFiber System, design allows for easy configuration and future and early detection of possible issues help
allowing bi-directional IEC 61850 fiber optic upgrades. improve system uptime.
communications. The HardFiber System is
• Flexible, modular I/O covering a broad range • Comprehensive device health diagnostic
designed to integrate seamlessly with existing
of input signals and tripping schemes performed at startup
UR applications, including protection functions,
• Types of digital outputs include trip- • Monitors the CT/VT input circuitry to validate
FlexLogic, metering and communications.
rated Form-A and Solid State Relay (SSR) the integrity of all signals
mechanically latching, and
Form-C outputs
• RTDs and DCmA inputs are available to
monitor equipment parameters such as
temperature and pressure

4 GEDigitalEnergy.com
F60 Feeder Protection System

Cyber Security – CyberSentry UR Communications • Implements Edition 2 of the standard across


the entire family of UR devices
CyberSentry UR enabled UR devices deliver full The F60 provides advanced commun-ications
• Provides full relay setting management via
cyber security features that help customers to technologies for remote data and engineering
standard SCL files (ICD, CID and IID)
comply with NERC CIP and NIST® IR 7628 cyber access, making it easy and flexible to use and
security requirements. integrate into new and existing infrastructures. • Enables automated relay setting
Direct support for fiber optic Ethernet provides management using 3rd party tools through
This software option delivers the following core standard file transfer services (MMS and SFTP)
high-bandwidth communications allowing
features:
for low-latency controls and high-speed • Increases the number of Logical Devices and
AAA Server Support (Radius/LDAP) file transfers of relay fault and event record data mapped to them, GOOSE messages, and
information. The available three independent reports to support different organizational
Enables integration with centrally managed needs for data transfer and reduce
Ethernet ports, redundant Ethernet option
authentication and accounting of all user dependency on generic logical nodes
and the embedded managed Ethernet switch
activities and uses modern industry best
provide the means to create fault tolerant • Configures GE Systems based on IEC 61850
practices and standards that meet and exceed
communication architectures in an easy, using universal 3rd party tools
NERC CIP requirements for authentication and
cost-effective manner without the need for
password management. • Multicast IEEE C37.118 synchrophasor
intermediary communication hardware. data between PMU and PDC devices using
Role Based Access Control (RBAC) The F60 supports the most popular industry IEC 91850-90-5
standard protocols enabling easy, direct
Efficiently administrate users and roles within Direct I/O Messaging
integration into DCS and SCADA systems.
UR devices. The new and advanced access
Direct I/O allows for the sharing of high-speed
functions allow users to configure up to five • IEC 61850 Ed. 2 with 61850-9-2 and
digital information between multiple UR
roles for up to eight configurable users with 61850-90-5 support
relays via direct back-to-back connections or
independent passwords. The standard “Remote • DNP 3.0 (serial & TCP/IP) multiplexed through a standard DS0 multiplexer
Authentication Dial In User Service” (Radius) is
• Ethernet Global Data (EGD) channel bank. Regardless of the connection
used for authentication.
method, direct I/O provides continuous
• IEC 60870-5-103 and IEC 60870-5-104
real-time channel monitoring that supplies
Event Recorder (Syslog for SEM) • Modbus RTU, Modbus TCP/IP
diagnostics information on channel health.
Capture all cyber security related events within • HTTP, TFTP, SFTP and MMS file transfer Direct I/O provides superior relay-to-relay
a SOE element (login, logout, invalid password communications that can be used in advanced
• SNTP and IEEE 1588 for time synchronization
attempts, remote/local access, user in session, interlocking, generation rejection and other
settings change, FW update, etc), and then • PRP as per IEC 62439-3
special protection schemes.
serve and classify data by security level using
Interoperability with Embedded • Communication with up to 16 UR relays
standard Syslog data format. This will enable
IEC 61850 Edition 2 in single or redundant rings rather than
integration with established SEM (Security Event
Management) systems. The new IEC 61850 implementation in the UR strictly limited to simplistic point-to-point
Family positions GE as an industry leader in this configurations between two devices
standard. • Connect to standard DS0 channel banks
through standard RS422, G.703 or
IEEE C37.94 interfaces or via direct fiber optic
connections
Fiber LAN, single
or redundant, for • No external or handheld tester required to
Source
added security provide channel diagnostic information

CB1 LAN Redundancy


Substation LAN redundancy has been traditionally
accomplished by reconfiguring the active network
Fault 1
topology in case of failure. Regardless of the type
CB2
of LAN architecture (tree, mesh, etc), reconfiguring
the active LAN requires time to switchover, during
which the LAN is unavailable. UR devices deliver
CB3 redundancy as specified by PRP-IEC 62439-3,
which eliminates the dependency on LAN
reconfiguration and the associated switchover
Fault 2 time. The UR becomes a dual attached node
that transmits data packets over both main and
redundant networks simultaneously, so in case
Reverse zone interlocking protection. By using the IEC 61850/GOOSE or hi-speed direct I/O capability of failure, one of the data packets will reach the
blocking signals can be transferred upstream, allowing for minimal coordination delays. Fast clearance
can be provided for Fault 1 while still maintaining coordination for Fault 2. receiving device with no time delay.

GEDigitalEnergy.com 5
F60 Feeder Protection System

Multi-Language Included in Launchpad is a document archiving Viewpoint UR Engineer provides the following
and management system that ensures critical configuration and commissioning utilities:
UR devices support multiple languages: English,
documentation is up-to-date and available when
French, Russian, Chinese, Turkish and German. • Graphical Logic Designer
needed. Documents made available include:
These language options are available on the • Graphical System Designer
front panel, in the EnerVista setup software, and • Manuals
• Graphical Logic Monitor
in the product manuals. Easily switch between • Application Notes
English and an additional language on the local • Graphical System Monitor
• Guideform Specifications
displays without uploading new firmware.
• Brochures Viewpoint Maintenance

• Wiring Diagrams Viewpoint Maintenance provides tools that


EnerVista Software will create reports on the operating status of
• FAQ’s
The EnerVista suite is an industry-leading set the relay, simplify the steps to download fault
of software programs that simplifies every • Service Bulletins and event data, and reduce the work required
aspect of using the F60 relay. The EnerVista for cyber security compliance audits. Tools
Viewpoint Monitoring
suite provides all the tools to monitor the status available in Viewpoint Maintenance include:
of the protected asset, maintain the relay, and Viewpoint Monitoring is a simple-to-use and
• Settings Security Audit Report
integrate information measured by the F60 into full-featured monitoring and data recording
DCS or SCADA monitoring systems. Convenient software package for small systems. Viewpoint • Device Health Report
COMTRADE and SOE viewers are an integral part Monitoring provides a complete HMI package • Single-Click Fault Data Retrieval
of the UR setup software included with every UR with the following functionality:
relay, to carry out postmortem event analysis and EnerVista Integrator
• Plug-&-Play Device Monitoring
ensure proper protection of system operation. EnerVista Integrator is a toolkit that allows
• System Single-Line Monitoring & Control
seamless integration of Multilin devices into
EnerVista Launchpad • Annunciator Alarm Screens new or existing automation systems. Included in
EnerVista Launchpad is a powerful software • Trending Reports EnerVista Integrator is:
package that provides users with all of • Automatic Event Retrieval • OPC/DDE Server
the setup and support tools needed for
• Automatic Waveform Retrieval • Multilin Drivers
configuring and maintaining Multilin products.
The setup software within Launchpad allows Viewpoint UR Engineer • Automatic Event Retrieval
for the configuration of devices in real-time • Automatic Waveform Retrieval
Viewpoint UR Engineer is a set of powerful
by communicating using serial, Ethernet , or
tools that allows the configuration and testing
modem connections, or offline by creating
of GE relays at a system level in an easy-to-
setting files to be sent to devices at a later time.
use graphical drag-and-drop environment .

Power System Troubleshooting


The F60 contains many tools and reports that simplify and reduce the amount of time required for troubleshooting power system events, increase uptime and
reduce loss of production.

Analyze feeder faults and disturbances using both analog and digital power
Record the operation of the internal F60 elements and external connected system quantities that are measured and recorded up to a rate of 64 samples
devices with 1ms time-stamped accuracy to identify the Sequence of per cycle.
Operation of station devices during faults and disturbances.

6 GEDigitalEnergy.com
F60 Feeder Protection System

User Interface 48 Configurable LED Indicators

The F60 front panel provides extensive local


HMI capabilities. The local display is used for
Multi-Language
monitoring, status messaging, fault diagnosis, Display
and device configuration. User-configurable • English
messages that combine text with live data can be • Russian
displayed when user-defined conditions are met. • French
• Chinese
• Turkish
• German

User-Programmable Pushbuttons

Typical Wiring

A B C

52

CONNECTION
F 5a

F 6a

F 7a

F 5a

F 6a

F 7a

F 8a

F 1a

F 1b

F 2a

F 2b

F 3a

F 3b

F 4a

F 4b
F 5c

F 6c

F 7c

F 5c

F 6c

F 7c

F 8c

F 1c

F 2c

F 3c

F 4c
VX
VB

VC

VB

VC
VA

VA

VX

IG5

IG1
VB

VC

VB

VC

IG
VA

VA

IA5

IA1

IB

IC
IA

IC5

IC1
IB5

IB1

8L/8M
H7a 6B I H1a TC 1
H7c H1 H1b
V
H8a H1c
H8c I H2a
H7b H2 H2b
V
H2c
H8b SURGE
H3a
H3 H3b TC 2
H3c
H4a
Digital Energy H4 H4b
Multilin H4c
H5a
H5
F60
H5b
H5c
H6a
H6 H6b
H6c
W5a 6A I W1a
W5c W1 W1b
V
W6a W1c
W6c I W2a
W5b W2 W2b
V
W2c
W7a
W3a
W7c
W3 W3b
W8a
W3c
W8c
W4a
W7b
W4 W4b
W8b SURGE W4c
P1a
6C

P1 P1b
U1a
6D

U1c P1c
U2a P2a
P2 P2b
U2c
U1b P2c
P3a
U3a P3 P3b
U3c P3c UR COMPUTER
U4a P4a
U4c 1 1 8
P4 P4b
U3b TXD 2 2 3 RXD
P4c
RXD 3 3 2 TXD
U5a P5a
4 4 20
U5c P5 P5b
SGND 5 5 7 SGND
U6a P5c
6 6 6
U6c P6a
P6 7 7 4
U5b P6b
8 8 5
U7a P6c
9 9 22
U7c P7a
P7 P7b
U8a
U8c P7c CONNECTOR
CONNECTOR
U7b P8a
P8 P8b
U8b SURGE RS-232
P8c
DB-9
B1b M1a
CRITICAL
1

(front)
6K

B1a FAILURE M1 M1b


B2b M1c
DC B3a M2a
B3b OUTPUT M2 M2b
B5b HI M2c
CONTROL
B6b LO POWER M3a
B6a M3 M3b
B8a
B8b
SURGE
FILTER
M3c This diagram is based on
M4a
M4 M4b the following order code:
M4c
M5a F60-HG4-HLH-F8L-H6B-M6K-
* Optic
Fibre Tx1 10BaseFL M5 M5b
Rx1
NORMAL
M5c P6C-U6D-W6A
Tx2 10BaseFL COM
Rx2
ALTERNATE
1
M6
M6a
M6b
This diagram provides an
Shielded 10BaseT M6c example of how the device is
Remote M7a
D1a
Device
D2a
RS485 M7 M7b wired, not specifically how to
M7c
D3a com
M8a wire the device. Please refer
D4b M8 M8b
D4a IRIG-B
Input M8c to the Instruction Manual for
Co-axial BNC
additional details on wiring
IRIG-B
Co-axial BNC Output based on various configurations.

Minimum 832769A5.CDR

X W V U T S R P N M L K J H G F D B
6 6 6 6 6 8 9 1
Inputs/ Inputs/ Inputs/ Inputs/
outputs outputs outputs outputs Inputs/ CT/VT CPU Power
PROVIDED
* * * * outputs Supply

GEDigitalEnergy.com 7
Ordering
F60 - * ** - H * * - F ** - H ** - M ** - P ** - U ** - W ** For Full Sized Horizontal Mount
Base Unit F60 Base Unit
CPU E RS485 + RS485 (IEC 61850 option not available)
J RS485 + multimode ST 100BaseFX
K RS485 + multimode ST Redundant 100BaseFX
N RS485 + 10/100 BaseT
T RS485 + three multimode SFP LC 100BaseFX. Req FW v7xx or higher
U RS485 + two multimode SFP LC 100BaseFX + one SFP RJ45 100BaseT.
Req FW v7xx or higher
V RS485 + three SFP RJ45 100BaseT. Req FW v7xx or higher
Software Options 00 No Software Options
(see note 1 below) 03 IEC 61850
06 PMU
07 IEC 61850 + PMU
A0 CyberSentry Lvl 1. Req UR FW 7.xx or higher
B0 IEEE 1588. Req UR FW 7.xx or higher
C0 PRP
D0 IEEE 1588 + CyberSentry. Req UR FW 7.xx or higher
M0 IEC 61850 + PMU + 61850-90-5
Mount / Coating H Horizontal (19" rack) - Standard
A Horizontal (19" rack) - Harsh Chemical Environment Option
V Vertical (3/4 size) - Standard
B Vertical (3/4 size) - Harsh Chemical Environment Option
User Interface F Vertical Front Panel with English Display
I Enhanced German Front Panel
J Enhanced German Front Panel with User-Programmable Pushbuttons
K Enhanced English Front Panel
L Enhanced English Front Panel with User-Programmable Pushbuttons
M Enhanced French Front Panel
N Enhanced French Front Panel with User-Programmable Pushbuttons
Q Enhanced Russian Front Panel
T Enhanced Russian Front Panel with User-Programmable Pushbuttons
U Enhanced Chinese Front Panel
V Enhanced Chinese Front Panel with User-Programmable Pushbuttons
W Enhanced Turkish Front Panel
Y Enhanced Turkish Front Panel with User-Programmable Pushbuttons
Power Supply H 125 / 250 V AC/DC
(see note 2 below) H RH 125/250 V AC/DC with redundant 125/250 V AC/DC power supply
L 24 - 48 V (DC only)
CT/VT DSP 8F Standard 4CT/4VT
8G Sensitive Ground 4CT/4VT
8H Standard 8CT
8J Sensitive Ground 8CT
8L 8L Standard 4CT/4VT w/ enhanced diagnostics
8M 8M Sensitive Ground 4CT/4VT w/ enhanced diagnostics
8N 8N Standard 8CT w/ enhanced diagnostics
8R 8R Sensitive Ground 8CT w/ enhanced diagnostics
8Z HI-Z 4CT (high impedance fault detection)
IEC 61850 Process Bus 81 8 Port IEC 61850 Process Bus Module
Digital I/O XX XX XX XX XX No module
4A 4A 4A 4A 4A 4 Solid State (No Monitoring) MOSFET Outputs
4C 4C 4C 4C 4C 4 Solid State (Current w/opt Voltage) MOSFET Outputs
4D 4D 4D 4D 4D 16 Digital Inputs with Auto-Burnish
4L 4L 4L 4L 4L 14 Form-A (No Monitoring) Latchable Outputs
67 67 67 67 67 8 Form-A (No Monitoring) Outputs
6C 6C 6C 6C 6C 8 Form-C Outputs
6D 6D 6D 6D 6D 16 Digital Inputs
6E 6E 6E 6E 6E 4 Form-C Outputs, 8 Digital Inputs
6F 6F 6F 6F 6F 8 Fast Form-C Outputs
6K 6K 6K 6K 6K 4 Form-C & 4 Fast Form-C Outputs
6L 6L 6L 6L 6L 2 Form-A (Current w/ opt Voltage) & 2 Form-C Outputs, 8 Digital Inputs
6M 6M 6M 6M 6M 2 Form-A (Current w/ opt Voltage) & 4 Form-C Outputs, 4 Digital Inputs
6N 6N 6N 6N 6N 4 Form-A (Current w/ opt Voltage) Outputs, 8 Digital Inputs
6P 6P 6P 6P 6P 6 Form-A (Current w/ opt Voltage) Outputs, 4 Digital Inputs
6R 6R 6R 6R 6R 2 Form-A (No Monitoring) & 2 Form-C Outputs, 8 Digital Inputs
6S 6S 6S 6S 6S 2 Form-A (No Monitoring) & 4 Form-C Outputs, 4 Digital Inputs
6T 6T 6T 6T 6T 4 Form-A (No Monitoring) Outputs, 8 Digital Inputs
6U 6U 6U 6U 6U 6 Form-A (No Monitoring) Outputs, 4 Digital Inputs
6V 6V 6V 6V 6V 2 Form-A (Cur w/ opt Volt) 1 Form-C Output, 2 Latching Outputs, 8 Digital Inputs
Transducer I/O 5C 5C 5C 5C 5C 8 RTD Inputs
5E 5E 5E 5E 5E 4 dcmA Inputs, 4 RTD Inputs
5F 5F 5F 5F 5F 8 dcmA Inputs
Inter-Relay Communications 7A 820 nm, multimode, LED, 1 Channel
7B 1300 nm, multimode, LED, 1 Channel
7C 1300 nm, singlemode, ELED, 1 Channel
7H 820 nm, multimode, LED, 2 Channels
7I 1300 nm, multimode, LED, 2 Channels
7J 1300 nm, singlemode, ELED, 2 Channels
7S G.703, 2 Channels
7W RS422, 2 Channels
76 IEEE C37.94, 820 nm, multimode, LED, 1 Channel
77 IEEE C37.94, 820 nm, multimode, LED, 2 Channel
Ordering Note: 1 . To view all the options available for L90, please visit GE’s On-Line Store http://store.gedigitalenergy.com/viewprod.asp?model=F60
2. Redundant power supply only available in horizontal unit. If redundant is chosen, must be same type. Maximum 2 per chassis

GEDigitalEnergy.com
IEC is a registered trademark of Commission Electrotechnique Internationale. IEEE is a registered
trademark of the Institute of Electrical Electronics Engineers, Inc. Modbus is a registered trademark of
Schneider Automation. NERC is a registered trademark of North American Electric Reliability Council.
NIST is a registered trademark of the National Institute of Standards and Technology.
GE, the GE monogram, Multilin, FlexLogic, EnerVista and CyberSentry are trademarks of General
Electric Company.
GE reserves the right to make changes to specifications of products described at any time without
notice and without obligation to notify any person of such changes. GEA-12595G(E)
English
Copyright 2015, General Electric Company. 150203