3P Plugs and Receptacles

Industrial Heavy Duty Interlocked


Application and Selection

Applications: Considerations for Options:


• Where extra protection is a requirement; Selection: • Special polarity and conduit
interlocked units provide dead front arrangements are available to meet
Environmental:
receptacles; connection cannot be made specific needs. See individual listing
or broken when unit is under load • The environment of the enclosure pages for details.
location in terms of NEMA/EEMAC type
• In areas where dirt, moisture, and required
corrosion are a problem; to supply
power for portable electrical equipment • Material and construction to withstand
and provide safe disconnect means and rough usage and corrosive atmospheric
short circuit protection conditions
Electrical:
• Sufficient current carrying capacity to
meet load requirements
• Compatibility with electrical system (new
or existing installations)
• Interchangeability of plugs with
hazardous and non-hazardous area
receptacles
Function:
• Switch vs. circuit breaker See "Quick
Selector Chart" below and
"Interchangeability Chart" on next page.

Quick Selector Chart


Receptacle NEMA/EEMAC Mating Electrical
Series Interlocked With Rating Plug Characteristics
CSR Disconnect switch 3, 4X, 12 APJ/NPJ Circuit breaker: Receptacle:
30, 60 amp. 30, 60 amp.
600VAC 600VAC
Fusible or non-fusible 3-wire, 4-pole
NBR Circuit breaker 3, 12 APJ/NPJ Circuit breaker: Receptacle:
100 amp. frame size 30, 60, 100 amp.
250VDC/600VAC 250VDC/600VAC
3-pole 3-wire, 3-pole
3-wire, 4-pole
NSR Disconnect 3, 12 APJ/NPJ Switch: Receptacle:
switch 30, 60, 100 amp. 30, 60, 100 amp.
250VDC/240VAC 250VDC/600VAC
600VAC 3-wire, 3-pole
3-pole 3-wire, 4-pole
Fusible or non-fusible
WSR Disconnect 3R, 4, 12 APJ/NPJ Switch: Receptacle:
switch 30, 60, 100 amp. 30, 60, 100 amp.
250VDC/240VAC 250VDC/600VAC
600VAC 3-wire, 3-pole
3-pole 3-wire, 4-pole
Fusible or non-fusible
WSRD Disconnect 3R, 12 APJ/NPJ Switch: Receptacle:
switch 60 amp. 60 amp.
250VDC/240VAC 250VDC/600VAC
600VAC 3-wire, 3-pole
3-pole 3-wire, 4-pole
Fusible or non-fusible
3P

1282 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds
Plugs and Receptacles 3P
Industrial Heavy Duty Interlocked
Interchangeability Chart

Interchangeability Chart
Many of the plugs listed in this section can be used interchangeably
with receptacles from other sections, both in hazardous and non-
hazardous areas, provided electrical rating and style of plug and
receptacle are the same. The following table is a summary of
possible combinations.

Can be Used
Plugs with these
Shown in Receptacle Listed in Plug & Receptacle
Section 3P Series Section Electrical Rating
AP AR 1P 200 and 400 amp.
3-wire, 4-pole
APJ/NPJ AR 1P 30, 60, 100 amp.
DBR, EBBR 4P 3-wire, 3-pole
FSQ, EPC, EPCB 4P 3-wire, 4-pole
SP BHR 4P 30, 60, 100 amp.
2-wire, 3-pole
3-wire, 4-pole
4-wire, 5-pole

3P

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds 1283
3P WSR, WSRD, WSRDW Interlocked 30, 60, 100A
NEMA 3, 3R, 4, 12
Arktite® Receptacles with Raintight
Enclosed Disconnect Switches Watertight
Corrosion-Resistant

WSR WSRD WSRDW

Aluminum Sheet Metal Sheet Metal


NEMA 3R, 4, 12 NEMA 3R, 12 Viewing Window
NEMA 3R, 12

Applications: • The switch enclosure covers are Standard Materials:


interlocked with the body and operating WSR and WSRD:
• The WSR and WSRD disconnect mechanism and cannot be opened when
switches are used as a service outlet for • Receptacle housings and plug exteriors
the plug is engaged and the switch is – copper-free aluminum
portable or fixed electrical equipment – closed ("ON"). When the switch is open,
generators, compressors, welders, etc. • Insulation (plug and receptacle) –
the switch cannot be put in a closed fiberglass-reinforced polyester
• They are designed for use in non- ("ON") position with the door open. • Pressure contacts – brass
hazardous areas where dust, moisture
WSR: • Crimp/solder contacts – leaded red
and corrosion may be a problem.
• Mounting lugs may be rotated 90° or brass
• Designed for flush or surface mounting. moved to the vertical centerline portion WSR:
• A fusible type switch, when used, also for pole mounting. • Enclosure – copper-free aluminum
provides short circuit protection. • Side hinged covers are retained in a • Operating handle – copper-free
closed position by compression spring aluminum
• Other exterior parts – stainless steel
Features: draw-pull catches, which permit the
WSRD:
opening or closing of the cover without
WSR and WSRD: • Enclosure – sheet steel
tools.
• Switches are NEMA type HD heavy duty • Operating handle – sheet steel
3-pole, with visible blades; a quick • The switch operating handle may be • Other exterior parts – stainless steel
make-and-break mechanism with padlocked in the "ON" or "OFF"
reinforced, positive pressure type blade position, thereby preventing
and jaw construction. Fusible types have unauthorized operation of the switch Standard Finishes:
fuse clips with steel reinforcing springs and/or opening of the enclosure. Up to • Copper-free aluminum – WSR enclosure,
of positive pressure type. Pressure three padlocks may be used. In addition, plug exteriors – natural
connectors are used for wire a unique hinge arrangement has been • Leaded red brass – electro-tin-plate
connectors. devised to allow the door of the unit to • Brass – natural
be padlocked. This feature allows • Sheet steel – baked grey enamel
• For maximum safety, the spring door operation while preventing unqualified or • Fiberglass-reinforced polyester – natural
receptacle at the bottom of the unit is unauthorized entry. (red)
mechanically interlocked with the switch
operating mechanism. The switch
cannot be closed until the plug is fully Certifications and Electrical Rating Ranges:
• 3 and 4 pole; fusible or non-fusible; 240
inserted and the plug cannot be Compliances: VAC, 250 VDC; 600 VAC
withdrawn or inserted unless the switch
is open. With the switch open, WSR: • 30, 60, 100 amperes
• 71/2 to 75 HP
3P

accidental plug withdrawal is prevented • NEMA 3R, 4, 12 (enclosure)


by the interlock mechanism. Withdrawal • UL Standard 98
can only be accomplished by activation WSRD: Options:
of the interlock release lever located on • NEMA 3R, 12 Description Suffix
the receptacle. • Interiors rotated 221/2° to the right
• UL Standard 98
• Enclosures are compact and rectangular (viewed from face).......................... S4
in shape with a gasketed, hinged door. • Auxiliary switch, 600 VAC-DC
• Enclosure, handle and other exterior heavy duty pushbutton station
parts are corrosion resistant. rating, can be supplied, and its
contacts will close after safety
switch contacts open and close
before safety switch opens............. S483

1284 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds
WSR, WSRD, WSRDW Interlocked 30, 60, 100A
NEMA 3, 3R, 4, 12
3P
Arktite® Receptacles with Raintight
Enclosed Disconnect Switches Watertight
Corrosion-Resistant
APJ/NPJ Plugs
WSR WSRD‡■ For viewing window see note 2
240VAC Max. Max. Max. Max.† Max.†
Conduit 600VAC HP HP HP 600VAC HP HP
Opening 250VDC Rating Rating Rating 250VDC Rating Rating
System Amps Sizes§ Cat. # 240VAC 480VAC 600VAC Cat. # 480VAC 600VAC
30 1 WSR3351* 71/ 2 15 20 WSRD3351* 15 20
3-Wire, 3-Pole
60 11/ 4 WSR6351* 15 30 50 WSRD6351* 30 50
Style 1, Fusible 100 11/ 2 WSR10351* 30 60 75 WSRD10351* 60 75
30 1 WSR3352* 71/ 2 15 20 WSRD3352* 15 20
3-Wire, 4-Pole 60 11/ 4 WSR6352* 15 30 50 WSRD6352* 30 50
Style 2, Fusible 100 11/ 2 WSR10352* 30 60 75 WSRD10352* 60 75
3-Wire, 3-Pole 30 1 WSR33541 71/ 2 15 20 WSRD33541 15 20
Style 1, Non- 60 11/ 4 WSR63541 15 30 50 WSRD63541 30 50
fusible 100 11/ 2 WSR103541 30 60 75 WSRD103541 60 75
3-Wire, 4-Pole 30 1 WSR33542 71/ 2 15 20 WSRD33542 15 20
Style 2, Non- 60 11/ 4 WSR63542 15 30 50 WSRD63542 30 50
fusible 100 11/ 2 WSR103542 30 60 75 WSRD103542 60 75
*Arranged for NEC Class H fuses. May be field converted to NEC Class J fuses.
§Furnished with reducer which may be removed to obtain one size larger opening. Locknut and bushing used must meet NEC requirements (WSR only).
†Ratings of unfused and fusible switches with time delay fuses.
■ Viewing window – add "W" to prefix, i.e.: WSRDW6352.
‡Conduit entrances not furnished.

APJ/NPJ Plugs
††Style 1 - Grounded through shell. Style 2 - Grounded
Outside Dia. of Cable, through extra pole and shell. For a detailed description of
Flexible Conduit or Style 1†† 3-wire, Style 2†† 3-wire, these grounding methods, see page 1230.
Amps Max. Volts Armored Cable 3-pole Cat. # 4-pole Cat. #
0.60 to 1.20 APJ3485
250 DC 0.55 to .070 NPJ3483
APJ3375
600 AC 0.70 to 0.85 NPJ3484
30
0.75 to 1.45 APJ6485
250 DC 0.75 to 1.07 NPJ6484
60 APJ6375
600 AC 1.07 to 1.35 NPJ6485
1.00 to 1.70 APJ10487
250 DC
100 0.93 to 1.21 APJ10377 NPJ10486
600 AC
1.21 to 1.50 NPJ10487

Dimensions
In Inches:
WSR
Dims. 30 Amps 60 Amps 100 Amps
a 113/4 113/4 147/8
b 201/16 201/16 265/16
c 69/16 69/16 99/16
d 71/4 71/4 81/4
e 215/32 215/32 27/8
f 2711/16 2811/16 353/8
g 43/4 51/4 71/4
gg 7 613/16 73/4
Mtg. Holes 3/8 3
/8 7
/16
Dim. "g" and "gg" are exposed portion of plug when
engaged with receptacle.

WSRD
3P

Dims. 60 Amps
g 513/16
WSR WSRD gg 613/16
Mtg. Holes 5
/16
Dim. "g" and "gg" are exposed portion of plug when
engaged with receptacle.

APJ NPJ APJ NPJ

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds 1285
3P Arktite® WSRD SM S901 30, 60 and 100 Amp
Enclosure Type 3, 4, 4X, 12
Watertight
Corrosion-Resistant
Stainless Steel Interlocked IP66
Receptacles UL and cUL Listed
Fused and Non-fused

WSRD SM S901 Series


Stainless Steel Arktite®
Interlocked Receptacles
Cooper Crouse-Hinds Arktite Stainless
Steel Interlocks prevent engagement and
disengagement of the plug under load,
providing safe portable connections and
extended product life.
Available in 30–100 Amp in both fused and
non-fused versions, the Stainless Steel
Interlock is rated Enclosure Type 4X
watertight and features an optional viewing
window.

Arktite Stainless Steel


Interlocked Receptacles:
• Supply power to portable or fixed
electrical equipment such as welders,
compressors, conveyors, portable tools,
lighting systems and similar equipment.
• Are used in damp or corrosive locations.
• Are ideal for use in wet locations and
hosedown areas.

Additional Features and Benefits:


• Heavy duty Arktite receptacle is compatible with existing Cooper Crouse-Hinds Arktite
plugs of same rating and configuration
• Self-wiping, naval brass contacts in receptacle assure reliable performance and long
dependable life
• Stainless steel interior hardware
• Ground bar supplied as standard and connected to 4th wire in receptacle
• UL and cUL Listed

Ordering Information: 3-Pole, 4-Wire - 600 VAC


Cooper Crouse-Hinds
3P

Weight Mating Arktite Plug


Amps Cat. # Description (lbs.) Cat. #
30 WSRDW3352 SM S901 Fused w/Window 24 APJ3485 & NPJ3485
30 WSRD33542 SM S901 Non-fused 22 APJ3485 & NPJ3485
30 WSRDW33542 SM S901 Non-fused w/Window 22 APJ3485 & NPJ3485
60 WSRDW6352 SM S901 Fused w/Window 30 APJ6485 & NPJ6485
60 WSRD63542 SM S901 Non-fused 29 APJ6485 & NPJ6485
60 WSRDW63542 SM S901 Non-fused w/Window 29 APJ6485 & NPJ6485
100 WSRDW10352 SM S901 Fused w/Window 36 APJ10487 & NPJ10487
100 WSRD103542 SM S901 Non-fused 35 APJ10487 & NPJ10487
100 WSRDW103542 SM S901 Non-fused w/Window 35 APJ10487 & NPJ10487

1286 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds
Arktite® WSRD SM S901 30, 60 and 100 Amp
Enclosure Type 3, 4, 4X, 12
Watertight
Corrosion-Resistant
3P
Stainless Steel Interlocked IP66
Receptacles UL and cUL Listed
Fused and Non-fused

Optional window allows viewing of


both visible blade and indicating type
fuses.

Plug locks into receptacle, providing


positive, worry-free power
engagement as well as watertight
protection.

Certifications and Compliances:


• UL Listed – (UL Standards 98, 1682)
• cUL Listed (Certified by UL to CSA Standards C22.2 Nos. 4, 182.1)
Complies with OSHA lockout/tagout
• Enclosure Type 3, 4, 4X, 12 requirements.
• IP66 Enclosure

Standard Materials: Standard Finishes:


• Enclosure – Type 304 stainless steel • Stainless Steel – natural
• Hardware – stainless steel • Aluminum – Corro-free™ epoxy powder
• Receptacle Housing – aluminum • Brass – natural
• Power Contacts – naval brass
3P

• Interlock Mechanism – stainless steel

Options:
Description Suffix
• Factory Installed Auxiliary Contacts........................................ S483
• Rotated Interior (221/2° to right)................................................ S4
Heavy-duty, epoxy coated cast
aluminum receptacle with stainless
steel interlocking mechanism for
superior durability and corrosion
resistance.

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds 1287
3P Arktite® WSRD SM S901 30, 60 and 100 Amp Watertight
Enclosure Type 3, 4, 4X, 12 Corrosion-Resistant
Stainless Steel Interlocked IP66
Receptacles UL and cUL Listed
Fused and Non-fused

Horsepower Ratings
240 VAC 240 VAC 480 VAC 480 VAC 600 VAC 600 VAC 250
Cat. # Amps Fusing (1 PH) (3 PH) (1 PH) (3 PH) (1 PH) (3 PH) VDC
WSRD33542 SM S901 30 Non-fused 5 10 7.5 20 10 30 5
WSRDW33542 SM S901 30 Non-fused 5 10 7.5 20 10 30 5
WSRDW3352 SM S901 30 Fused 1.5 (3) 3 (7.5) 3 (7.5) 5 (15) 3 (10) 7.5 (20) 5
WSRD63542 SM S901 60 Non-fused 10 20 20 50 25 60 10
WSRDW63542 SM S901 60 Non-fused 10 20 20 50 25 60 10
WSRDW6352 SM S901 60 Fused 3 (10) 7.5 (15) 5 (20) 15 (30) 10 (25) 15 (50) 10
WSRD103542 SM S901 100 Non-fused 15 40 30 75 40 100 20
WSRDW103542 SM S901 100 Non-fused 15 40 30 75 40 100 20
WSRDW10352 SM S901 100 Fused 7.5 (15) 15 (30) 10 (30) 25 (60) 15 (40) 30 (75) 20
Note:
Values for Non-Fused units are maximum horsepower.
Values for Fused units are standard horsepower with standard fuse and (maximum horsepower with time delay).

Dimensions
In Inches:

Amps A B C D E
30 5.47 16.49 23.49 9.00 8.61
60 7.99 18.49 25.49 11.52 8.61
100 8.47 24.18 31.18 12.00 8.61
3P

1288 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds
3P

3P

US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds 1289


3P Arktite® CSR Series 30, 60 and 100 Amp Watertight
Enclosure Type 3, 4, 4X, 12 Corrosion-Resistant
Non-metallic Interlocked IP66
Receptacles UL and cUL Listed
Fused and Non-fused

CSR Series Compact


Interlocked Arktite®
Receptacles
Cooper Crouse-Hinds
interlocked receptacles prevent
engagement and disengagement of
the plug under load, providing safe
portable connections and extended
product life.

Arktite Compact Interlocked


Receptacles are Used:
• To supply power to portable or fixed
electrical equipment such as welders,
compressors, conveyors, portable tools,
lighting systems and similar equipment.
• In damp or corrosive locations.
• In wet locations.
• In hosedown areas.

Additional Features and Benefits:


• Enclosure Type 4X, Watertight, IP66.
• Compact enclosure is designed to fit into the web of an I-beam.
• Heavy duty Arktite® receptacle is compatible with existing Cooper Crouse-Hinds Arktite®
plugs of same rating and configuration.
• Bussmann® CubeFuse™ with Indicator – the world's first "finger-safe" industrial power fuse.
• Front mounted handle permits the interlocked receptacles to be easily mounted side by
side or in tight spots.
• Molded-in-place mounting feet require only four screws to mount the entire unit.
• UL and cUL Listed.

Ordering Information: 600 VAC


Amps Configuration Hub Size Fusing Cat. # Mating Cat. #
3P

30 3W, 4P 1" Fused CSR3352 APJ3485/NPJ3484


30 3W, 4P 1" Non-fused CSR33542 APJ3485/NPJ3484
60 3W, 4P 11/4" Fused CSR6352 APJ6485/NPJ6484
60 3W, 4P 11/4" Non-fused CSR63542 APJ6485/NPJ6484

1290 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds
Arktite® CSR Series 30, 60 and 100 Amp
Enclosure Type 3, 4, 4X, 12
Watertight
Corrosion-Resistant
3P
Non-metallic Interlocked IP66
Receptacles UL and cUL Listed
Fused and Non-fused

Fully rated for 30A and 60A at 600


VAC. For use with Bussmann
CubeFuse. Fuses not included.

Plug locks into receptacle, providing


positive, worry-free power engagement
as well as watertight protection.

Certifications and Compliances:


• UL Listed – (UL Standards 508, 1682)
• cUL Listed (Certified by UL to CSA Standards C22.2 Nos. 14,
182.1)
• Enclosure Type 3, 4, 4X, 12 Complies with OSHA lockout/
• IP66 Enclosure tagout requirements.

Standard Materials: Standard Finishes:


• Enclosure – fiber reinforced polyester • Aluminum – Corro-free™ epoxy powder
• Hardware – stainless steel • Brass – natural
• Receptacle Housing – aluminum • Stainless Steel – natural
• Power Contacts – naval brass
3P

• Interlock Mechanism – stainless steel

Options:
Description Suffix
• Factory Installed Auxiliary Contacts................................... S483 Heavy-duty, epoxy coated cast
• Rotated Interior (221/2° to right)........................................... S4 aluminum receptacle with stainless steel
interlocking mechanism for superior
Horsepower Ratings durability and corrosion resistance.
Amps 250 VAC 480 VAC 600 VAC
30 10 HP 20 HP 25 HP
60 20 HP 40 HP 40 HP

US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds 1291


3P Arktite® CSR Series 30, 60 and 100 Amp
Enclosure Type 3, 4, 4X, 12
Watertight
Corrosion-Resistant
Non-metallic Interlocked IP66
Receptacles UL and cUL Listed
Fused and Non-fused

Dimensions
In Inches:

Amps Style Dimension A Dimension B Hub Size


30 Fused 18.26 8.00 1"
30 Non-fused 18.26 7.87 1"
60 Fused 19.26 8.00 11/4"
60 Non-fused 19.26 7.87 11/4"
3P

1292 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds
WSQC Interlocked Arktite® 30 and 60A Raintight 3P
600 VAC Dust-tight
Receptacles with Enclosed NEMA 3R, 12
Switches
APJ Plugs

Applications:
WSQC dead front interlocked receptacles
with APJ, NPJ, BP or FP plugs are used:
• To supply power to portable electrical
equipment such as hand lamps, lighting
systems, power tools, conveyors,
welders, compressors, etc.
• In damp, wet or corrosive locations
• Indoors or outdoors in non-hazardous
areas
• In locations where mounting area is
confined and compact equipment is
required

Features:
• NEMA 3R, 12
• Rainproof, dust-tight
• Available in 30 and 60 amps
• Horsepower rated switch
• Smallest footprint for interlocked
Dimensions
receptacles In Inches:
• Padlockable in OFF position; meets
OSHA lockout/tagout requirements
• Compatible with Arktite® APJ aluminum
and NPJ Krydon® material non-metallic
plugs

Certifications and
Compliances:
• NEMA 3R, 12
• CSA Standard: C22.2 No. 14, 182.1
• UL and cUL Listed

Standard Materials:
• Enclosure – copper-free aluminum
• Cover and spring door – copper-free
aluminum
• Insulator – Krydon® material
Amps A B C D E
• Contacts – brass
30A 31/8 93/4 — 53/4 3
/8
• Cover gasket – neoprene
60A 5 147/16 81/2 7 13
/32

Horsepower Ratings:
Single Phase Three Phase
Amps 120V 240V 480V 600V 120V 240V 480V 600V
30A 2 5 71/2 71/2 3 71/2 15 15
60A 10 25 30 10 25 30

Ordering Information:
Amps Hub Config. Cat. # Options:
3P

Description Suffix
3
/4" 2W3P WSQC2330
• Interior rotated 221/2° to the right
1" 2W3P WSQC3330 (viewed from face)................................. S4
30A WSQC2340
3
/4" 3W4P ex: WSQC5640 S4
1" 3W4P WSQC3340
11/2" 2W3P WSQC5630
60A
11/2" 3W4P WSQC5640

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds 1293
3P NBR Arktite® Interlocked NEMA 3, 3R, 4*, 4X*, 12
Watertight
Receptacles with Enclosed Corrosion-Resistant
Circuit Breakers
APJ/NPJ Arktite Plugs
Applications: Certifications and
NBR Arktite interlocked receptacles with Compliances:
enclosed circuit breakers are used:
• NEMA 3, 3R, 4*, 4X*, 12
• To supply power and provide short
• ANSI/UL Standard: 489
circuit protection, thermal overload
protection, and a disconnect means for • UL Standard: 1682
portable electrical equipment such as • CSA
motor generator sets, compressors,
conveyors, and other similar equipment Standard Materials:
• In locations where corrosion is present • Enclosure, covers and operating handles
such as in offshore and marine – Krydon fiberglass-reinforced polyester
locations, pulp and paper mills, chemical material
plants, food processing, and sewage
treatment plants • Operating shafts – stainless steel
• Indoors and outdoors in damp, wet or • Receptacle housings – copper-free
hosedown locations aluminum
• Receptacle insulators – Krydon material
• Crimp/solder contacts – leaded red
Features: brass
• Enclosures are made of Krydon® high
impact strength fiberglass-reinforced
polyester material having excellent Standard Finishes:
resistance to corrosion and heat • Copper-free aluminum – baked on
• Receptacles are mechanically powder epoxy
interlocked with circuit breakers which • Stainless steel – natural
provide a disconnect means, short • Enclosure – natural
circuit protection, and thermal time delay • Receptacle insulators – natural (red)
overload protection
• Brass – natural Interchangeability of Plugs
• For maximum safety, the spring door
• Leaded red brass – electro-tin-plated
receptacle at the bottom is mechanically With Other Non-hazardous
interlocked with the circuit breaker
operating mechanism. The circuit Electrical Rating Range: and Hazardous Location
breaker cannot be closed until the plug • Receptacles – 30, 60 and 100 amperes Receptacles:
is fully inserted and the plug cannot be • Plugs listed for use with NBR
withdrawn unless the breaker is open • Circuit Breakers – 100 ampere frame
size assemblies are standard Arktite
• Enclosure has hinged access door for APJ/NPJ plugs. Other standard
easy wiring and maintenance. Three APJ/NPJ and CPH plugs of the same
Note: For additional dimensional data,
screws, hidden behind access door in rating, style and number of poles may
door frame, prevent disassembly when see page 496, enclosure catalog number
be used with NBR receptacles, as well
door is locked NCB1024.
as EBBR, EPC and EPCB receptacles
• Enclosure access door is mechanically listed in Section 4P
interlocked with operating handle and Options: • Portable equipment, suitable for the
cannot be opened unless operating Description Suffix locations and equipped with the proper
handle operator is in "OFF" position Special polarity – for use where two plug, can be used with non-hazardous
• A Krydon material hub (not mounted) is or more receptacles of the same rated AR receptacles, DBR and WSR
supplied with each enclosure as follows: ampere rating, style and number of interlocked receptacles located in non-
poles are to be installed on the hazardous locations, with EBBR, EPC
Rating Hub Size (In.) Cat. # same premises for use of different and EPCB receptacles for Class I,
30A /4
3
NHUB2 voltages. Receptacle interior rotated Groups B, C, D hazardous locations,
60A 11/4 NHUB4 221/2° to right (viewed from face) and with DR and DBR interlocked
100A 2 NHUB6 plug changed to match ..................... S4 receptacles for Class II, Groups F, G
Hubs for other conduit sizes can be hazardous locations, and with NBR/NSR
For alternate hub sizes, see page 646 supplied. See page 646. interlocked receptacles for wet and
• Receptacle has self-closing spring door corrosive locations
assembly to provide environmental
protection
3P

• Operating handle can be padlocked in


"OFF" position. Breaker is trip-free of
handle and will open under short circuit
or overload when handle is in the "ON"
position
• Provided with top and bottom mounting
feet which may be rotated 90° to vertical
or horizontal mounting positions

*30 and 60A Style 2 only.

1294 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds
NBR Arktite® Interlocked 3-Pole, 600 VAC
NEMA 3, 3R, 4, 4X, 12
3P
Receptacles with Enclosed Watertight
Circuit Breakers Corrosion-Resistant
APJ/NPJ Arktite Plugs▲
100 Ampere Frame Size with Non-interchangeable TripठAPJ/NPJ Plugs
Enclosure 600 VAC
Receptacle Hub Ckt. Without With With Cable Grip and Neoprene
With Spring Size Brkr. Circuit Cutler-Hammer Circuit Bushing
Door Housing (In.) Amps Breaker Cat. # Breaker Cat. #
Style 1†
20 NBR53731 WT20 3
30 amp., 30 NBR53731 WT30 3
3
/4 40 NBR53731 NBR53731 WT40 3*
3-wire,
3-pole 50 NBR53731 WT50 3*
50 NBR56731 WT50 3
60 amp., 60 NBR56731 WT60 3
3-wire, 11/4 70 NBR56731 NBR56731 WT70 3*
3-pole 90 NBR56731 WT90 3*
100 NBR56731 WT100 3* APJ
60 NBR51731 WT60 3
100 amp., 70 NBR51731 WT70 3
3-wire, 2 90 NBR51731 NBR51731 WT90 3
3-pole 100 NBR51731 WT100 3
Style 2†
20 NBR53742 WT20 3
30 amp., 30 NBR53742 WT30 3
3
/4 40 NBR53742 NBR53742 WT40 3*
3-wire,
4-pole 50 NBR53742 WT50 3*
50 NBR56742 WT50 3 NPJ
60 amp., 60 NBR56742 WT60 3
3-wire, 1 /41 70 NBR56742 NBR56742 WT70 3* Style 1† Style 2†
4-pole 90 NBR56742 WT90 3* Cable 3-wire, 3-wire,
100 NBR56742 WT100 3*
O.D. 3-pole 4-pole
60 NBR51742 WT60 3 Amps Range Cat. # Cat. #
100 amp.,
70 NBR51742 WT70 3
3-wire, 2 NBR51742 0.60 to 1.20 APJ3375 APJ3485
90 NBR51742 WT90 3
4-pole 0.55 to 0.70 NPJ3483
100 NBR51742 WT100 3 30
*Circuit breaker trip rating may exceed receptacle rating for welding equipment applications only, as higher trip rating may 0.70 to 0.85 NPJ3484
not protect wiring.
†Style 1 – Grounded through shell. Style 2 – Grounded through extra pole and shell. For a detailed description of these
grounding methods, see page 1231.
0.75 to 1.45 APJ6375 APJ6485
§Also available with interchangeable trip breakers. Specify on order. 60 0.75 to 1.07 NPJ6484
‡ For detailed information on circuit breaker selection, see Section 3C.
1.07 to 1.35 NPJ6485
▲ Pressure connectors are standard. Crimp/solder type terminators are optionally available for 3 and 4-pole 30, 60 and
100 ampere. For details, see page 1233. To specify, add the suffix "T" to the catalog number. 1.00 to 1.70 APJ10377 APJ10487
For example: APJ3375-T (Plug).
100 0.93 to 1.21 NPJ10486
Dimensions (In Inches): 1.21 to 1.50 NPJ10487

Amps b a aa
30 313/ 8 413/ 16 7
60 33 513/ 16 613/ 16
100 333/ 4 65/ 8 73/ 4
Dim. "a" and "aa" are exposed portion of plug when
engaged with receptacle.
3P

APJ NPJ

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds 1295
3P NSR Arktite® Interlocked NEMA 3, 3R, 4*, 4X*, 12
Watertight
Receptacles With Enclosed Corrosion-Resistant
Disconnect Switches
APJ/NPJ Arktite Plugs
Applications:
NSR Arktite interlocked receptacles with
enclosed disconnect switches are used:
• To provide a power disconnect for fixed
or portable electrical equipment such as
welders, generators and compressors
where the switch will be subject to
frequent operation
• To provide short circuit protection when
a fusible switch is needed
• In non-hazardous indoor or outdoor
areas where corrosion, dust, hosedown
and moisture may be a problem such as
in offshore and marine locations, pulp
and paper mills, chemical plants,
sewage treatment plants and food
processing facilities
Features:
• Enclosures are made of Krydon® high
impact strength fiberglass-reinforced
polyester material having excellent
resistance to corrosion and heat
• Switches are NEMA type HD heavy duty
3-pole, enclosed blade; a quick make-
and-break mechanism with reinforced,
positive pressure type blade and jaw
construction. Fusible switches have fuse
clips with steel reinforcing springs
Interchangeability of Plugs
• For maximum safety, the spring door Standard Finishes:
receptacle at the bottom is mechanically With Other Non-hazardous • Copper-free aluminum – baked-on
interlocked with the switch operating
mechanism. The switch cannot be
and Hazardous Location powder epoxy
closed until the plug is fully inserted and Receptacles: • Stainless steel – natural
the plug cannot be withdrawn unless the • Plugs listed for use with NSR assemblies • Leaded red brass – electro-tin-plated
switch is open are standard Arktite APJ/NPJ plugs. • Enclosure – natural (gray)
• Switch enclosure access door is Other standard APJ/NPJ and CPH plugs • Insulator (plug and receptacle) – natural
mechanically interlocked with switch and of the same rating, style and number of (red)
cannot be opened unless switch poles may be used with NSR
operator is in "OFF" position receptacles, as well as with EBBR, Options:
• Enclosure has hinged access door for EPC and EPCB receptacles listed in Description Suffix
easy wiring and maintenance. Three Section 4P Special polarity – for use where two
screws, located behind access door in • Portable equipment, suitable for the or more receptacles for the same
door frame, prevent disassembly when locations and equipped with the proper ampere rating, style and number of
door is locked plug, can be used with non-hazardous poles are to be installed in the same
• A Krydon material hub (not mounted) is rated AR receptacles, DBR and WSR area for use on different voltages.
supplied with each enclosure as follows: interlocked receptacles located in non- Receptacle interior rotated 221/2° to
hazardous locations, with EBBR, EPC right (viewed from face) and
Rating Hub Size (In.) Cat. # and EPCB receptacles for Class I, matching plug ................................... S4
30A /4
3
NHUB2 Groups B, C, D hazardous locations,
60A 11/4 NHUB4 with DR and DBR interlocked Hubs for other conduit sizes can be
100A 2 NHUB6 receptacles for Class II, Groups F, G supplied. See page 646.
For alternate hub sizes, see page 646 hazardous locations, and with NBR/NSR
interlocked receptacles for wet and
• Receptacle has self-closing spring door
corrosive locations
assembly to provide environmental
protection
3P

• Mounting feet may be rotated 90° to Standard Materials:


horizontal or vertical mounting positions • Receptacle housings – copper-free
• Switch operating handle may be aluminum
padlocked in the "OFF" position, • Insulators (plug and receptacle) – Krydon
preventing unauthorized operation of the material
switch • Crimp/solder contacts – leaded red
brass
Certifications and • Enclosure and operating handle –
Compliances: Krydon fiberglass-reinforced polyester
• NEMA 3, 3R, 4*, 4X*, 12 material
*30 and 60A Style 2 only.
• UL Standard: 1682, 98 • Other exterior parts – stainless steel

1296 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds
NSR Arktite® Interlocked 240 and 600 VAC
250 VDC
3P
Receptacles With Enclosed NEMA 3, 3R, 4, 4X, 12
Disconnect Switches Watertight
Corrosion-Resistant
APJ/NPJ Arktite Plugs††
240VAC/250VDC 600VAC/250VDC
Style 1† Style 2† Style 1† Style 2†
Conduit 3-wire, 3-wire, AC DC 3-wire, 3-wire, AC DC
Opening 3-pole 4-pole HP HP 3-pole 4-pole HP HP
Amps Sizes§ Cat. # Cat. # Rating Rating Cat. # Cat. # Rating Rating
Fusible
30 3
/4 NSR331‡ NSR332‡ 3 5 NSR3351* NSR3352* 71/2 5
60 11/4 NSR631‡ NSR632‡ 5 10 NSR6351* NSR6352* 20 10
100 2 NSR1031‡ NSR1032‡ 10 20 NSR10351* NSR10352* 30 20
Non-Fusible
30 3
/4 NSR3341 NSR3342 71/2 5 NSR33541 NSR33542 20 5
60 11/4 NSR6341 NSR6342 20 10 NSR63541 NSR63542 50 10
100 2 NSR10341 NSR10342 30 20 NSR103541 NSR103542 75 20

APJ/NPJ Plugs
600VAC/250VDC, with Cable Grip and Neoprene
Bushing

Cable Style 1† Style 2†


Amps O.D. Range 3-wire, 3-pole Cat. # 3-wire, 4-pole Cat. #
*Arranged for NEC Class H fuses. May be field converted to NEC Class J fuses.
0.60 to 1.20 APJ3375 APJ3485 ‡Fuse clips accommodate NEC Class H fuses. For NEC Class J fuses, use 600V switches.
30 0.55 to 0.70 NPJ3483 †Style 1 – Grounded through shell. Style 2 – Grounded through extra pole and shell. For a
0.70 to 0.85 NPJ3484 detailed description of these grounding methods, see page 1231.
§For alternate hub sizes, refer to catalog page see page 818.
0.75 to 1.45 APJ6375 APJ6485 †Style 1 - Grounded through shell. Style 2 - Grounded through extra pole and shell. For a
60 0.75 to 1.07 NPJ6484 detailed description of these grounding methods, see page 1231
1.07 to 1.35 NPJ6485 ††Pressure connectors are supplied as standard. To specify crimp/solder type terminators
add the suffix "T" to the catalog number. For example: APJ3375-T (Plug).
1.00 to 1.70 APJ10377 APJ10487
100 0.93 to 1.21 NPJ10486
1.21 to 1.50 NPJ10487

Dimensions
In Inches:
Amps b a aa
30 313/8 413/16 7
60 33 513/16 613/16
100 333/4 65/8 73/4
Dim. "a" and "aa" are exposed portion of plug when
engaged with receptacle.
3P

APJ NPJ

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2010 Cooper Crouse-Hinds 1297