C O N T E N T S General 4
Features 6
Application Data 8
Technical Data 10
Unit Type and Versions 12
Specification Guide 13
Certificate 18
General
The switchgear is isolated by grounded metal •CB poles are horizontally installed in the circuit
plates so that any live part is not exposed to breaker compartment.
the operator when the door is opened.
•The three position switch in the bus
Compact design with three-phase enclosure allows compartment prepares 3 conditions
very systematic construction.
In addition, the switching section can be dismantled –Current interrupted condition(“OPEN”)
or added in a very short time without the busbar –Current alive condition(“CLOSED”)
being disconnected. –Earthing condition(“EARTH”)
The switchgear is applicable at voltage ratings up to •All operating mechanisms are fitted outside of
24 kV(25.8 kV) for indoor installation. the gas compartment.
The switchgear and all components are designed,
manufactured and tested in accordance with the •Mechanical interlocks ensure safe operating
latest standards including : sequence.
04 05
Features
Compactness
•Compact and systematical design Bay control and protection unit HIMAP-BC
•Optimum engineering provides the benefits of the following.
•Modular design
•Intelligent digital control and protection system •Economic advantage
•High reliable vacuum interrupters •State-of-the-art technology
•Panels coupled by plug-in connecting system •Reliability and availability
•Extension capability of existing systems to the •International standard
both sides •Flexibility
•Factory-assembled panels with insulating gas at •Experience sharing
operating pressure •Easy operation and mounting
•Simple interface and application
•High reliability and safety This unit is divided into five completely separate
•Safe operation areas each with its own front doors.
•Interlock system and monitoring
•Three-position switch mechanically interlocked •Bus compartment
with circuit breaker •Circuit breaker compartment
•Circuit breaker function accompanied by •Cable compartment
earthing function in combination with a three •Low voltage compartment
position switch •Gas duct
•Operating mechanism to be accessed from
outside of enclosure.
•Independent compartments
•Duct for pressure relief
•Inert SF6 insulating gas prevents fire in the
system and contact to oxidation.
•Safe manual closing of energy storage circuit
breaker with spring charge mechanism.
06 07
HMGS-G10
Application Data
1 2 3 4 5 6
LP LP
2350
3600(3800)
BUS1
BUS2
The design criteria dictate that all performance tests meet the requirements of the standards.
The basic IEC test series include short circuit, BIL, dielectric continuous current, mechanical life,
thermal and environmental conditions.
08 09
HMGS-G10
Technical Data
1 Gas Duct
2 Bursting Disc
3 Bus Connector
5 Current Transformer
3-Position Switch 10
Mechanism
2 Bursting Disc
Circuit Breaker 9
Mechanism 6 Cable Socket
1 Gas Duct
5 Current Transformer
8 Power Cable
Medium Voltage > > SF6 Gas Insulated Metal-clad Switchgear
10 11
HMGS-G10
Optimum user-friendly control for digital type bay control unit, HIMAP-BC.
HMGS-G10 is suitable for both single and double bus systems.
BUS1
BUS2
Specification Guide
SF6 Gas Insulated Metal-clad switchgear, The switchgear consists of bus compartments and
HMGS-G10 designed up to 24,000 volts 3-phase circuit breaker compartment that are hermetically
3 wire 50/60 Hz system. pressure sealed with SF6 gas.
The switchgear shall be rated up to 24,000 volts •Welded stainless steel enclosure
and has horizontally installed vacuum circuit •Modular design
breakers. •Duct for pressure relief
•Panels coupled by plug in bus connectors
The switchgear includes vacuum circuit breakers, •Cable connection inner cone plug in system
meters, relays, etc.
Note : Color denoted information to be provided to Circuit breaker(CB) compartment contains feeder
the purchaser regarding : busbars(tie off conductors), Vacuum Interrupter(VI),
Current Transformer(CT) and cable sockets.
1. Choice of alternates
2. Addition of optional features CB compartment is filled with SF6 gas and
3. Specific information equipped with a safety device (bursting disc)
activated by overpressure.
12 13
HMGS-G10
Specification Guide
Bus(BB) compartments contain main busbar, feeder Low voltage compartment contains CB operating
busbar (tie off conductors) including mechanism, 3PS and DS operating mechanisms,
the 3-position switch(3PS) or disconnector(DS) bay control unit and mounting plate.
and filled with SF6 gas with safety devices
(bursting disc) activated by overpressure.
Gas Duct
Gas duct on the top/rear is to guide the exhausted hot gas flow from the gas filled
compartments(CB, BB compartments) when the internal arc fault occur.
Medium Voltage > > SF6 Gas Insulated Metal-clad Switchgear
Cable Compartment
Cable compartment contains the incoming or outgoing cable supports, earthing busbars and fixing facilities.
The relief device, easy-to-open door to the rear gas duct, exhausts, hot gas flow can be opened
when internal arc fault occur.
Power Cable
Relief Device
(easy-to-open-door) Earthing Bus Cable Clamp & Support
14 15
HMGS-G10
Specification Guide
Bus Connector
16 17
Medium Voltage
Certificate
18 19
HHIS-WC-SE-B13-03 2008. 1 Designed by Design Korea