R410A Tropical Split Type Technical Manual Troubleshooting

If the air conditioner fails and does not meet the above phenomena, check the system as the following table:
Symptoms Causes Handling methods
Power supply fails. Operate after power resumes.
Power switch is not connected. Connect the power supply properly.
The unit does not Replace the fuse or check whether
Fuse blows out or circuit breaker snaps off.
work electric leakage occurs.
The remote controller or the wire controller Check the remote controller or wire
fails. controller.
Temperature setting is higher than the
Air flowing
room temperature in cooling mode. Or
normally but Temperature setting is improper.
temperature setting is lower than the
completely can’t
room temperature in heating mode.
cooling
3-minute protection of compressor. Waiting for 3 minutes.
The system is lack of refrigerant. Or there is Fix the leakage places, and charge the
too much refrigerant in the system. proper quantity of refrigerant.
Air or non-condensable gas exists in the Vacuum the system and charge
The unit starts or
refrigerant system. refrigerant again.
stops frequently
Compressor fails. Repair or replace the compressor.
The voltage is too high or too low. Install a voltage regulator.
The refrigerant pipe is obstructed. Locate and replace that part.
The heat exchanger of outdoor unit or indoor
Clean the heat exchanger.
unit is too dirty.
The filter is too dirty. Clean the filter.
Air inlet or air outlet of the indoor/ outdoor Remove obstacles to keep well
unit is blocked. ventilating.
Doors or windows of the room are open. Close all the windows and doors.
Poor cooling effect
Directly exposed to sunlight. Use curtain to obstruct sunlight.
Too many heat sources in the room. Reduce the heat sources.
The outdoor ambient temperature is too
The cooling effect is poor but normal.
high.
Fix the leakage places, and charge the
The system is lack of refrigerant.
proper quantity of refrigerant.
The outdoor ambient temperature is lower
Use an assistance heating device.
than -7℃.
Poor heating Doors or windows of the room are not closed
Close the doors and windows properly.
effect tightly.
Fix the leakage places, and charge the
The system is lack of refrigerant.
proper quantity of refrigerant.