PROJECT: Construction of Expansion of Yashoda Hospital- Phase-1

GRAND SUMMARY
S No Item Supply Installation Total Remarks

1 SANITARY FIXTURES

2 WATER SUPPLY SYSTEM

3 PUMPS & MOTORS

4 INTERNAL & EXTERNAL SANITARY PIPING SYSTEM

5 RAIN WATER DISPOSAL SYSTEM

6 WATER TREATMENT PLANT WORKS

7 HOT WATER SYSTEM

TOTAL AMOUNT
In Words:

For Employer Page 1 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0
S.No DESCRIPTION UNIT QTY RATE AMOUNT
Supply Installation Supply Installation
A SANITARY FIXTURES

1 Supply, Fixing in position of Wall mounted European Water Closet suite No's 100.00
of approved make & colour, comprising of :

Glazed vitreous chin aware Wall mounted European water closet of


approved make and co lour with wash down pattern fixed to wall with
necessary CI / MS chair bracket, GI bolts & nuts, WC connector with
rubber gaskets as per manufacturer's specifications, including cutting
and making good the walls & flooring etc. complete. Providing and
fixing matching colour solid plastic seat & cover of approved make
conforming to IS: 2548 specifications and bearing ISI mark.

25mm Concealed flush valve immediate releasing spring type having all
parts made of corrosion resistant materials and of approved make with
necessary piping from flush valve to the water closet as per water closet
manufacturer's specification for satisfactory operation of system. The
top cover plate shall be made of engineering plastic with CP finish /
brass with CP finish / polished SS and the flush actuation plate
preferably be of square / circular shape with central push button, with
necessary 25mm diameter GI/ Threaded PVC piping not exceeding 1m
in length from flush valve to water closet for satisfactory operation of
system.

Providing and fixing of Floor Mounted European water closet


2 comprising the following including cutting and making good the No's 8.00
walls /floor wherever required all complete.(For Disabled Toilets)

For Employer Page 2 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0
White vitreous China Floor mounted pan with `P' or `S' trap of Make,
model, size as specified in the enclosed list. Matching color
polypropylene seat cover with necessary C.P. brass hinges, rubber
bushes etc. of Make as specified in the enclosed list

25mm Concealed flush valve immediate releasing spring type having all
parts made of corrosion resistant materials and of approved make with
necessary piping from flush valve to the water closet as per water closet
manufacturer's specification for satisfactory operation of system. The
top cover plate shall be made of engineering plastic with CP finish /
brass with CP finish / polished SS and the flush actuation plate
preferably be of square / circular shape with central push button, with
necessary 25mm diameter GI/ Threaded PVC piping not exceeding 1m
in length from flush valve to water closet for satisfactory operation of
system.

Supply, Fixing of CP brass Health faucet of approved make comprising


3 of: heavy casted CP brass wall flange and one CP brass Health faucet of No's 108.00
approved make with 1m long PVC tube of 8mm dia.Complete all as
specified and directed with approved fittings.

Supply, Fixing of oval under counter wash basin with CP bottle trap of
4 approved colour, comprising of : (Common toilets for Ground Floor to No's 24.00
3rd Floor)

Glazed vitreous china ware oval counter top wash hand basin of
approved make of size 650x410mm .The gap between the counter and
the top of the basin shall in no case exceed 5mm, silicone sealant shall
be applied to the top of the basin before fixing in position so as to
completely seal the gap. The excess sealant shall be wiped out using a
clean blade flush with the basin inner profile.

For Employer Page 3 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

One 15mm CP brass quarter turn type pillar cock wth one no of 15mm
CP brass quarter turn type angle stop cock with ceramic disc cartridge of
approved make with necessary wall flanges and two 15mm PVC flexible
inlet connection pipe 600mm long with CP brass nuts at both ends and
necessary rubber washers complete.

One 32mm heavy quality CP brass waste coupling & CP brass bottle trap
with extension piece & wall flange of approved make and conforming to
IS specifications. 40mm dia.UPVC pipe with specials from extension
piece of bottle trap to the ceiling suspended trap.The scope includes
necessary UPVC pipe ,fitting & necessary sealent to connect Floor Trap
etc,complete.

Supply ,Fixing of wash basin comprising the following including cutting


5 and making good the walls/ floors wherever necesssary all complete as No's 112.00
per specifications .(For all Guest rooms & Consultant rooms)

Wall hung wash basin (without pedestal) from approved make


white/Colour Wash basin including cutting and making good the walls/
floors wherever necesssary all complete as per specifications

Fixing of 15mm n.b C.P pillar cock,32mm heavy quality CP brass waste
coupling & CP brass bottle trap with extension piece & wall flange of
approved make and conforming to IS specifications. 40mm PVC waste
pipe with specials from extension piece of bottle trap to the floor trap,
length not exceeding 1m concealed in the wall, including cutting and
making good the floors and walls.

6 Supply, Fixing of approved make Coat Hook fixed to wall with cp screws No's 108.00
and required all accessories etc,complete.

For Employer Page 4 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supply, Fixing of approved make Soap Dispenser fixed to wall with cp


7 screws and required all accessories etc,complete.(For all common No's 65.00
toilets & OP Rooms)

8 Supply, Fixing of CP brass Towel Ring of 150mm dia.fixed to wall,with No's 65.00
CP screws.(For all common toilets & OP Rooms)

Supply, Fixing of approved make Toilet Paper Holder fixed to wall with
9 No's 108.00
cp screws and required all accessories etc,complete.

Supply, Fixing of approved make automatic hand drier operated with


10 sensors,air flow up to 15cms, fixed to wall with cp screws and required No's 8.00
all accessories etc,complete.

Supply, Fixing of approved make CP Brass Towel Rail of 20mm


11 No's 49.00
dia.600mm long fixed to wall with CP brass screws etc., complete

12 Supply, Fixing of CP brass Tumbler Holder fixed to wall,with CP screws. No's 49.00

Supply&Fixing of Flat back Half White Large URINAL fixed with screws to
wall with waste coupling,bottle trap,waste pipe drop to lower
floor&connected to P-Trap with 50mm dia.Galvanized Iron pipe .The
13 scope includes necessary GI fittings(T-Joint) & necessary sealent to No's 32.00
connect P- Trap etc,complete.. Concealed Sensor for URINALS with
installation box &control cock,CP Dome and all accessories completed
provision for manual operation to be made with concealed stop cock.

Supply&Fixing of Granite Urinal Division Plates of 1200mmx600mm size


14 No's 28.00
with wall cutting and making good completed

For Employer Page 5 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0
Supply, Fixing of CP brass Shower assembly comprising of the
15 No's 49.00
following :
15 mm CP brass overhead shower with hand shower and heavy casted
shower arm with wall flange of approved make.
One quarter turn type with ceramic disc cartridge, CP brass Single Lever
Diverter with built in spout & CP bend for overhead shower of
approved make. Complete all as specified & directed with approved
fittings.
Supply ,Fixing of CP brass Shower assembly comprising of the
16 No's URO
following :
15 mm CP brass overhead shower with hand shower and heavy casted
shower arm with wall flange of approved make.
Fixing of wall mixer with bend provision for overhead shower of
approved make. Complete all as specified & directed with approved
fittings. The scope includes supply of necessary accessories
etc,complete.

17 Supply, Fixing of Stainless steel sink & drain board of approved make of No's 10.00
size 61cmx25cmx45cm supported on suitable RC or Granite platform.

Two No's 15mm sink cocks with swivel casted spout conforming to IS
specifications.

One 40mm heavy quality CP brass waste coupling of approved make


with removable crumb cup strainer. 40mm dia. UPVC pipe with specials
from extension piece of bottle trap to the ceiling suspended trap.The
scope includes necessary UPVC fittings & necessary sealent to connect
Floor Trap etc,complete.

Fixing of CP long body bib cock for wash area water supply conforming
18 to IS specifications.The scope includes supply of necessary accessories No's 6.00
etc,complete.
Supply & fixing of approved make soap dish fixed to wall with CP screws
19 No's 49.00
etc.complete.(Near Shower )

For Employer Page 6 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supply, Installation, testing and commissioning of commercial water


purifier of water flow rate 15.0 Ltr/Hr,Including all components as per
20 manufacture specifications,including connections from water supply No's 20.00
line and final connection to water cooler electric wiring & plug top
etc.with all accessories complete.

Grab bar -Supplying & fixing floor - wall mounted safety armrest for
handicapped,made of stainless steel profiled tube with multi-
functional, ergonomic grip area, antislip profile, diameter 32 mm with
21 one 90 deg. & one 180 deg.and two extruded fastening flanges with two No's 8.00
holes each,made of stainless steel 8 mm diameter, 3 mm thick, with
plastic collar, including fastening set. Execution selectable right-hand or
left-hand.

Providing & fixing of Glazed vitreous china ware Lab sink with drain
board (SD) comprising of :drain board of approved make size
450x370mm supported on suitable RC or granite platform .One 15mm
CP brass quarter turn type sink mixer and two no's of 15mm CP brass
quarter turn type angle stop cock with ceramic disc cartridge of
22 approved make with necessary wall flanges conforming to IS No's 6.00
specifications. One 40mm heavy quality CP brass waste coupling of
approved make with removable crumb cup strainer. 40mm dia. UPVC
pipe with specials from extension piece of bottle trap to the ceiling
suspended trap.The scope includes necessary UPVC & fittings &
necessary sealent to connect Floor Trap etc,complete.(For Scrub Area)

Supply ,installation of hand sanitizer with require accessories


23 No's 110.00
etc,complete.
Fixing of CP angular stop cock for water cooler and , RO plant water
24 supply conforming to IS specifications.The scope includes supply of No's 20.00
necessary accessories etc,complete.

For Employer Page 7 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0
Fixing of CP long body pillar tap for lab sinks conforming to IS
25 specifications.The scope includes supply of necessary accessories No's 12.00
etc,complete.

Supply and fixing of electric storage type verticle/horizontal Instant


water heater of approved make & colour,storage tank manufactured
from 99% pure Copper which is suitable for both hard & soft water with
all other internal fittings,internal insulation, inside non-return valve as
26 per IS 2083-1978 with three core heavy duty copper cable 1m long , No's 10.00
15Amps 3 pin plug,CP brass angle valves, fusible plug automatic
pressure releaf valve, 600mm CP copper connecting pipe with end nuts
for hot & cold water connections etc. complete. Capacity : 25
Ltrs(Each) (For Delux Rooms)

TOTAL FOR SANITARY FIXTURES


B WATER SUPPLY SYSTEM

Providing, laying, jointing, fixing, testing, commissioning of Composite


PL pipes with Brass & crimp fittings conforming to IS 15450:2004. The
scope includes providing threaded fittings having brass threaded ring for
outlets for connecting metallic pipes and fittings, including chasing the
walls / floors, making holes, clamping to walls and restoring the same to
1 original conditions etc., complete all as specified and directed and as
per manufacturer's specification.The scope includes ceiling suspended
8mm dia.GI Hitech clamps/anchor rods (Spacing between two supports
as per specifications )for suspended pipes wherever it necessary. Note:
Brass fittings are used for utility connections & crimp fittings for all
vertical & external pipes.

The entire piping system in part or as a whole has to be tested to a


hydraulic test pressure of 7 kg/sq.cm for a period of not less than 24
hours. the piping shall be concealed / commissioned only after
satisfactory testing of the system.

For Employer Page 8 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0
a) 20MM (Internal Dia) Rmt 1100.00
b) 25MM (Internal Dia) Rmt 600.00
c) 32MM (Internal Dia) Rmt 250.00

Providing, laying, jointing, fixing, testing, painting, commissioning GI


medium quality type pipe of approved make conforming to IS:1239,
including cost of GI specials, cutting the pipes to the required lengths,
threading, jointing the pipes, chasing,making holes necessary in walls &
floors, clamping to walls / supports using fabricated MS
2 brackets(40x40x5mm Angle or 40 x6mm Flat) of approved design, GI
threaded U clamps on the bracket, HITECH pipe supports & restoring
the walls & floors to the original conditions etc., complete all as
specified and directed. The exposed pipes shall be painted with 2 coats
of approved synthetic enamel paint over a coat of metal primer,
including making the necessary colour bands as specified in the
tech.spects.

The entire piping system in part or as a whole has to be tested to a


hydraulic test pressure of 7 kg/sq.cm for a period of not less than 24
hours. the piping shall be concealed / commissioned only after
satisfactory testing of the system.
a) 20MM Dia. Rmt 610.00
b) 25MM Dia. Rmt 140.00
c) 32MM Dia. Rmt 300.00
d) 40MM Dia. Rmt 100.00
e) 50MM Dia. Rmt 265.00
f) 65MM Dia. Rmt 550.00

For Employer Page 9 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supply & fixing of heavy quality Ball valves shall have body of carbon
steel. The ball and the shaft shall be of stainless steel. The seat shall be
of PTFE. The valve shall be complete with socket weld ends and the
float of copper sheet. The minimum thickness of copper sheet used for
3 making the float shall be 0.45mm for a float exceeding 115mm dia. The
body of the high pressure ball valve when assembled in working
condition with the float immersed to not more than half of its diameter
shall remain closed against a test pressure of 3.5kg/sqcm.of following
sizes, conforming to IS:1703: 1977,PN 1.0 and bearing ISI mark,
including testing, making good the leakages etc., complete.

a) 20 mm Dia No’s 80.00


b) 25 mm Dia No’s 80.00
c) 32 mm Dia No’s 12.00
d) 40 mm Dia No’s 10.00
e) 50 mm Dia No’s 28.00

Providing & fixing butterfly valve (Body : Grey Cast Iron, Shaft: SS, Disc :
SG Iron (Rilson coated), Liner: HT - EPDM) (upto 150mm dia with hand
4 lever operation & above with gear box operation). Tested to a pressure
not less than 10Kg/Sq.cm. Including rubber gasket, flanges, nuts, bolts,
washers & painting complete as required.

a) 65 mm Dia No’s 19.00


b) 80 mm Dia No’s 1.00
c) 100 mm Dia No’s 1.00

For Employer Page 10 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supply, delivery, installation, testing, commissioning of digital water


level controller , digital display of water level in the tank, trigger for
automatic operation of pump set when the water level reaches low
5 level, including fixing necessary stainless steel sensors, float level Each 6.00
switch, probes, etc. The control cabling from panel to sump, making
connections from the level controller to the pump starter, necessary
conduiting shall have to be done by qualified electrical contractor only.

Supplying and fixing of digital percentage level indicator for water


storage tanks consisting of display unit and level sensor. The display unit
should have 2-1/2 digit seven segment LED to display the levels as 0%,
6 10% --- 100%. The unit should be weather proof and wall / panel Each 6.00
mounted input to the unit should be 230V AC. The level sensor should
consists of float operated magnetic float switch with one PUF float
suitable mounting flange and flame proof enclosure.

Providing and fixing in position 65mm dia flanged Cast Iron dirt box Y-
7 Type Strainer having body fabricated in Cast Iron and strainer made of Each 2.00
SS perforated sheet having perforations of suitable size.

Constructing water meter chamber or valve chamber of sizes as


mentioned below over 100mm thick CC 1:4:8 leveling course, 100mm
thick CC 1:3:6 for foundation with 150mm offset around, 230mm thick
8 brick masonry in CM 1:3 using table mold bricks, 12mm thick plaster on
outside, inside surfaces in CM 1:3, providing, fixing frame & cover in
100mm thick RCC 1:2:4 using 20mm metal, finishing top surface with
CM 1:3 plaster and finished smooth.

1200x1200mm internal clear dimension with 900x900mm SFRC frame &


cover of medium duty (MD-10 grade)(For Municipal Water Incoming Each 1.00
Line)

For Employer Page 11 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

9 Supply and fixing of following mentioned dia. Water meter inclusive of


2 isolating ball valves, GI union and strainer inside the valve chamber.

a) 50mm dia. Each 1.00


Supply,Laying of 50mm(28 Gauge) thick Rock Wool insulation with
10 mechanical protection, GI wire mesh( 14 Gx3/4”) and Al(28 Gauge)
cladding.(All Terrace ,Vertical Down Takes & internal toilet Hot Water
Pipes) .
a) 20MM Dia. Each 530.00
b) 25MM Dia. Each URO
c) 32MM Dia. Each 180.00

Supply, fixing in position auto air release valve (ARV)of 25mm n.b. of
approved make with body made of Cast Iron and Rubber Coated
11 Wooden Brass with Brass Plug and other moving parts of stainless steel No’s 8.00
& Screwed Ends as per IS 14845,PN 1.0.The scope includes provision of
ball valve (between ring main & ARV ) for any maintenance shall be
made.

Supplying & fixing Flanged CI non return valve with necessary nuts,
12 bolts, rubber gaskets etc. complete. of approved make. (To be placed at
pump room )
a) 40mm dia. No’s 2.00
b) 65mm dia. No’s 4.00
Providing and fixing of following mentioned dia dial pressure gauge to
13 read up to 15kg/sq.cm, to be fixed on delivery main of pump sets with
isolation cock.
a) 25mm dia. No’s 4.00
Construction of P.C.C/ Brick Masonry pedestals
14 600mmx300mmx150mm with MS brackets & GI clamps for laying pipes No’s 250.00
on terrace

15 Supplying & fixing of 20 mm dia. hose bib with valve of 20 mm dia. (For No’s 10.00
external gardening) .

For Employer Page 12 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0
Supply, installation, testing & commissioning of Ductile iron(DI )
16 medium duty rectangular manhole cover with frame for the feasibility No’s 12.00
of access in the tank Size : 600 x 600 (65 kg)
Providing and fixing in position G.I. vent with brass mosquito proof
17 coupling and air filter including return bend, complete as required. The No’s 24.00
entire fitting shall be hot dip galvanised.
Providing and fixing PPP Water hammer arrestors complete with
18 necessary fittings for inlet dia of 20mm. No’s 8.00

Providing & fixing manhole foot rests; poly propylene, steel


reinforcement The polypropylene shall confirm to ASTM D-410 and shall
19 be injection molded around 12mm dia Fe-415 Steel reinforcing bar. The No’s 80.00
foot rest shall be provided in RCC walls / brick walls as per requirement
of design / project manager.

The external water piping system in part or as a whole has to be filled


with water mixed with filtered bleaching powder solution of 50ppm
chlorine and kept for a contact shower rose, pillar cocks, flushing cistern
20 etc., shall be operated with this water for effective disinfection Care LS 1.00
shall be taken to see that this water is not used for drinking and other
purposes. The system shall be flushed with potable water before
commissioning.

Liaison charges for Making water supply connection to municipal Water


supply main with all the necessary works which shall be paid as per
actual including cutting the corporation road and making good the road
21 LS 1.00
after the connection. the contractors responsibility shall include
submitting the papers to the corporation follow-up and get the approval
etc.,complete (only statutory charges to be paid by the client)

Supply & Fixing of G.I Puddle Flanges of various dia and size made out
of G.I. with screwed ends, cap and plain for embedment n concrete as
22 necessary with suitable accessories, consumables welding accessories
including placing in position, complete for Under Ground Sumps &
Overhead Tanks.

For Employer Page 13 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0
a) 20mm dia. No’s 6.00
b) 80mm dia. No’s 10.00
c) 100mm dia. No’s 2.00
d) 160mm dia. No’s 2.00
e) 250mm dia. No’s 2.00
f) 50mm dia. No’s 11.00
g) 40mm dia. No’s 14.00
Supplying, installing, testing and Commissioning approved make
GM/Brass pressure reducing station(PRS) with union, ball valve /
23 butterfly valve 3 nos of required dia, pressure gauge 2 nos with all
necessary accessories etc. complete all conforming to IS.
a) 40mm dia. No’s 3.00
b) 32mm dia. No’s 6.00
c) 25mm dia. No’s 6.00
d) 20mm dia. No’s URO
Supply ,installation of Electrically operated Solenoid valve to be
mounted on the over head tank incoming line, 220V/24V/50 Hz, de-
24 energized closing following mentioned dia.with necessary cabling from
Over Head Tank to Under Ground Sump & required accessories
complete.
a) 25mm Dia. No’s URO

25 Supplying, fixing in position approved make following mentioned


diameter Foot Valve conforming to IS 778 with unions etc., complete.

a) 65mm dia. No’s 2.00


b) 50mm dia. No’s 2.00

Supply , fixing of approved make manually operated 25mm dia .drain


26 valve on terrace ring mains (Ball Valve) made of cast iron TFE coated, No’s 4.00
hand wheel operated with Screwed ends for two sides & one end
threaded outlet for Drain Water as per ASTM 150 standards(PN 1.0)

TOTAL FOR WATER SUPPLY SYSTEM

For Employer Page 14 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0
C PUMPS & MOTORS

Supply of Vertical Multi stage Centrifugal Pump with suitable capacity


415V, 3-phase,50Hz motor and coupling with base frame having
discharge capacity of 10 Cum/Hr against total head of 65m from all
causes, with starter consists of suitable MPCB, Cont actor, Overload
1 Set 1.00
relay, Single Phase Prevent or, Push buttons, LED on indicators, all in
comings in Weather Proof box and necessary suitable copper cables
from starter panel to pump etc., complete as required.(Domestic Water
Lifting Pump)

Each Pump capacity : 10.0 cu.m/Hr


No of Pumps : 1 working + 1 standby
Delivery head : 65 m
Suction : Negative of 3.0 meters

Supply of Vertical Multi stage Centrifugal Pump with suitable capacity


415V, 3-phase,50Hz motor and coupling with base frame having
discharge capacity of 5 Cum/Hr against total head of 65m from all
causes, with starter consists of suitable MPCB, Cont actor, Overload
2 Set 1.00
relay, Single Phase Prevent or, Push buttons, LED on indicators, all in
comings in Weather Proof box and necessary suitable copper cables
from starter panel to pump etc., complete as required.(Flush Water
Lifting Pump)

Each Pump capacity : 5.0 cu.m/Hr


No of Pumps : 1 working + 1 standby
Delivery head : 65 m
Suction : Negative of 3.0 meters

For Employer Page 15 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supply, delivery, testing, commissioning of De-watering submersible


pump made of Cast Iron Construction .Impeller shaft shall be S.S
construction with mechanical seal suitable for building application..The
3 unit shall include TEFC motor suitable for 415V,3Phase,50Hz & Set 2.00
Insulation -Class F,IP 68 Protection and Automatic ON/OFF Level Switch,
Base plates,Coupling,Nylon ropes for lifting pumps with necessary
control cables etc,complete.(De water Pumps for Lower Basement floor
Drain)

Each Pump capacity : 50.0 cu.m/Hr


No of Pumps : 1 working + 1 standby
Delivery head : 20 m

Supply, delivery, testing, commissioning of In line Booster pump with


suitable capacity 230V, 1-phase,50Hz motor and coupling with base
frame having discharge capacity of 5 Cum/Hr against total head of 20m
4 Set 1.00
from all causes , without starter, complete as required .The scope
includes necessary pressure vessel & switch for the auto on/off of the
pump.

Each Pump capacity : 5.0 cu.m/Hr


No of Pumps : 1 working + 1 standby
Delivery head : 20 m
Pressure Vessel for Auto ON/OFF : 25 Ltrs Capacity

Supply, delivery, testing, commissioning of De-watering submersible


pump made of Cast Iron Construction .Impeller shaft shall be S.S
construction with mechanical seal suitable for building application..The
unit shall include TEFC motor suitable for 415V,3Phase,50Hz &
5 Insulation -Class F,IP 68 Protection and Automatic ON/OFF Level Set 1.00
Switch, ,Base plates,Coupling,Nylon ropes for lifting pumps with
necessary control cables etc,complete.(Drain water lifting pump at
pump room)

Each Pump capacity : 5.0 cu.m/Hr


No of Pumps : 1 working + 1 standby
Delivery head : 20 m

For Employer Page 16 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0
TOTAL FOR PUMPS & MOTORS
D INTERNAL & EXTERNAL SANITARY PIPING SYSTEM

Supply,fixing of 150mm deep Multi floor traps of self cleansing design


with following mentioned outlet diameter of approved make, including
1 making connection with PVC soil/waste pipes using rubber gaskets and
top shall be covered with removable CP strainer & cockroach jolly etc.,
complete all as specified & directed.

a) 110mm dia. NO's 16.00


b) 75mm dia. NO's 180.00

Supply,laying of under floor UPVC drainage pipes, specials of approved


make conforming to to IS:13592 Type 'B' (6 kg/sq.cm.) using lubricant as
per manufacturer's specification, including cutting the pipes square to
the required lengths, necessary wall cutting, chasing & restoring to the
original condition, testing for water tightness etc. (Specials at junctions
of lateral pipe must have access doors for inspection).The formation of
2 pipe sockets by heating the pipe shall not be permitted the joints for
plain ended pipes shall be made using couplers if necessary. Rate shall
also include the cost of GI 'U' clamps of 12/16mm thick to be provided
at not more than 1.5m c/c for horizontal ceiling suspended pipes.
(Concealed & Ceiling Suspended Piping) .The scope includes FRP
sealant for all UPVC pipe joints for ceiling susspended pipes where
ever it is necessary.

a) 40mm Dia. RMT 250.00


b) 75mm Dia. RMT 550.00
c) 110mm Dia. RMT 310.00

For Employer Page 17 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supply,laying of under floor UPVC drainage pipes, specials & rubber


rings of approved make conforming to to IS:13592 Type 'B' (6 kg/sq.cm.)
and as per manufacturer's specification, including cutting the pipes
square to the required lengths, necessary wall cutting, chasing &
restoring to the original condition, testing for water tightness etc.,
(Specials at junctions of lateral pipe & vertical stack must have access
doors for inspection and vent cowls for soil,waster water & anti
siphonage pipes). The formation of pipe sockets by heating the pipe
3 shall not be permitted the joints for plain ended pipes shall be made
using couplers if necessary. Rate shall also includes the cost of GI 'U'
clamps to be provided at not more than 2.0m c/c for vertical pipes . The
GI 'U' clamps shall be made of hot dip galvanized 10mm dia MS rod
threaded at both ends and of length to suit the secure fixing of the pipe
on the bracket of the clamping system with necessary nuts, plate
washers and rubber insertions etc., complete (Vertical Down Take
Pipes).

a) 75mm Dia. RMT 750.00


b) 110mm Dia. RMT 400.00
c) 160mm Dia. RMT URO

For Employer Page 18 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Providing, laying, jointing MDPE pipes and specials PE-80 grade (PN 6
Class )conforming to As per ISO4427-1996 Suitable for Max allowable
design stress of 6.3MPA (SDR11) by electrofusion jointing as per
manufacturers specifications, providing flanges for fixing of valves as
required, including hydrostaitc pressure testing the pipe system to a
hydraulic pressure of 7kg/sq.cm or 3 times the working pressure
whichever is higher, the pipe system shall be observed for a period of
not less than 6 hours, making good leaks if any etc., complete.The scope
4 includes necessary Electrofusion Couplers,Tees ,bends and,necessary
tapping saddles etc.complete.Rate shall also includes the cost of GI 'U'
clamps to be provided at not more than 1.0m c/c for horizontal pipes .
The GI 'U' clamps shall be made of hot dip galvanized 10mm dia MS rod
threaded at both ends and of length to suit the secure fixing of the pipe
on the bracket of the clamping system with necessary nuts, plate
washers and rubber insertions etc., complete(7th & 6th Floor ceiling
suspended & basement header pipes)

i) 160MM DIA. RMT 80.00


ii) 110MM DIA. RMT 20.00
iii) 75MM DIA. RMT 40.00
iv) 200MM DIA. RMT 200.00

For Employer Page 19 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supply ,fixing of pipe support system for pipes using brackets of length
as per details fabricated from 50x50x6mm or suitable MS angles etc., as
per approved design and drawings. The brackets shall be fixed to the
wall at all levels at a distance not less than 2.0m c/c at all heights up to
80m above ground level with necessary scaffolding as necessary with 4
5 Nos of 10mm dia.expansion fasteners having a safe working load of 150
kg each with necessary nuts, washers etc.,complete. The brackets shall
be installed true to plumb vertically with necessary insertions, spacer
blocks etc as required etc., complete. The clamps shall be painted with 2
coats of approved synthetic enamel paint over a coat approved metal
primer.

Note: The length of the bracket shall be equal to the sum of the outer
diameters of all pipe and 50mm for working space per pipe of size 15 to
Kg 1678.00
75mm and 100mm for working space per pipe for pipes of size 75mm
and above diameters.

Supplying, installing, testing and commissioning of R.C.C Socket and


Spigot Pipes(NP2 CLASS) conforming to BIS 458/1988, laid to the
required level and grade with rubber rings / joining in CM 1:3 and filling
6 the excavated trench with approved quality saturated sand on sides,
bottom and top surface of pipe with all leads and lifts, making necessary
connections as required etc., complete.

a) 225mm Dia RMT URO


b) 300mm Dia RMT URO

Providing weep hole for raised floor toilet area with 40mm pipe for
draining moisture, including making necessary holes in the sunk slab,
7 No's 40.00
placing pipe sleeve in position, grouting the opening in CM 1:2 etc.,
complete.

For Employer Page 20 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supplying and fixing cast brass clean out plug with suitable insert keys
8 for opening male threaded plug jointed to GI socket caulked to soil &
waste pipe as required & completed…

a) 75 mm dia No's 10.00


b) 110 mm dia No's 35.00
c) 160 mm dia No's 15.00
d) 200 mm dia No's 6.00
9 Supply of vent pipes mosquito proof grating suitable for the ventilation No's 12.00
purpose of the various tanks

Drilling with core cutting machine in RCC floor slab etc., for laying pipes
and rendering the same in RCC 1:2:4, finishing the same to the
satisfaction of the owner or his authorized representative etc., including
10
nominal reinforcement wherever required, . The quoted rate shall also
include for providing EPOXY based water proofing compound for sealing
the joints around the pipes as approved by site incharge.

a) 110mm dia. No's 140.00


b) 160mm dia. No's 110.00
c) 65mm dia. No's 50.00

Supplying, installing and commissioning of the ACO make grease


separators model no ECO-FPI NS-2 with necessary Extension RCC rings,
11 with direct suction with concrete cover and cover and cover plate of Each 1.00
load class D 400 with 120 lites and sludge storage of 400 liters.

For Employer Page 21 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Construction of Inspection Chamber with best quality, approved fly ash


bricks in CM 1:6, 600x600x1000mm depth over a bed of 150mm thick
PCC 1:4:8, walls plastered smooth inside in CM 1:3 and outside with
CM 1:3 with sponge finish benching and channeling in PCC 1:2:4. The
12 Inspection Chamber shall be provided with 600x600mm rectangular Each 3.00
medium duty approved make frame and cover etc., complete. The
quoted rate shall also include for necessary excavation, refilling,
disposing off surplus earth with in a lead of 300M etc., complete.

Providing & laying best quality Salt glazed stoneware gully trap of size
100mm square with 100mm outlet embedded in plain cement concrete
1:4:8 (20mm metal), providing & fixing 100mm square CI grating on top
of the trap, all the above encased in a chamber of 300x300mm built
with 115mm thick brick masonry using first class country bricks in CM
13 Each 5.00
1:3 over a bed of CC 1:4:8 using 40mm down size metal 100mm thick,
plastering with CM 1:3,13mm thick inside,exposed to surface, finished
smooth with a floating coat of neat cement, providing & fixing SFRC
frame & cover of size 300x300mm etc., complete all as specified &
directed.

TOTAL FOR INTERNAL & EXTERNAL SANITARY PIPING SYSTEM


E RAIN WATER DISPOSAL SYSTEM

For Employer Page 22 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supply,laying of under floor UPVC drainage pipes, specials & rubber


rings of approved make conforming to to IS:13592 Type 'B' (6 kg/sq.cm.)
and as per manufacturer's specification, including cutting the pipes
square to the required lengths, necessary wall cutting, chasing &
restoring to the original condition, testing for water tightness etc.,
(Specials at junctions of lateral pipe & vertical stack must have access
doors for inspection and vent cowls for soil,waster water & anti
siphonage pipes). The formation of pipe sockets by heating the pipe
1 shall not be permitted the joints for plain ended pipes shall be made
using couplers if necessary. Rate shall also includes the cost of GI 'U'
clamps to be provided at not more than 2.0m c/c for vertical pipes . The
GI 'U' clamps shall be made of hot dip galvanized 10mm dia MS rod
threaded at both ends and of length to suit the secure fixing of the pipe
on the bracket of the clamping system with necessary nuts, plate
washers and rubber insertions etc., complete (Vertical Down Take
Pipes).

a) 160mm diameter RMT 250.00


b) 110mm diameter RMT 50.00

Supply,fixing of PVC grating for inlet of rain water pipes at terrace level
2 in CM 1:2, including making bores in the roof, setting in position and
forming smooth rain water inlet gutter to direct rain water into the rain
water pipe etc., complete all as specified and directed.

a) 160x160mm No's 6.00


b) 110x110mm No's 2.00

For Employer Page 23 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Rain water recharge pit of size 2mx1.5m x3m clear size , two layers are
top & bottom filled with 60mm metals up to depth of 600mm each ,
middle layer is filled with 40mm thick metal up to depth of 600mm
thick, 1-2mm coarse sand of 200mm depth layers on the top of filter
3 media, including with boring & laying of 150mm slotted G I epoxy No's 10.00
coated pipes up to a depth of 6mtr long as directed includes with full
size slotted RCC reinforced cover of 600x600x50mm on top and with
necessary excavation, refilling etc. complete as directed & including all
taxes , duties finish to complete item.

Supply & installion of Heavy moulded(with stand up to 25.0 tons of


vehicle load) 150mm wide x 150mm Depth x 1000 Length PVC ramp
4 No's 12.00
drain grating at entrance of the ramps(Each Ramp two No's) . Make :
ECO
TOTAL RAIN WATER DISPOSAL SYSTEM
F WATER TREATMENT PLANT WORKS

Supply, installation, Testing & commissioning of Reverse Osmosis


Plant(RO) , the features of the plant is , Plant skid made from MS
(Powder coated) Pre filtration in FRP/ SS vessel. Pre filter with sediment
and housing. High pressure pumps (Rotary vane type/ vertical) Anti
1 scalene dosing pump. Membrane housing (FRP)/ Stainless Steel) High Set 1.00
pressure & Low pressure control switch. Full electronic/ MCB panel
with Auto water level sensor. High quality Astral PVC/ SS Piping.
Membrane cleaning system. Fully automatic with TDS meter, flow meter
& pressure gauge . (For Drinking Water Purpose only)

Capacity : 500 Ltrs/Hour


2 Supply ,installation of 500 Ltrs Food Grade HDPE/PVC water storage tank No's 1.00
with required necessary accessories etc,complete.

For Employer Page 24 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supply, installation, Testing & commissioning of Water Softener with


strongly acidic cation exchanger in sodium ions and thus produce soft
water of less than 50ppm ( Raw Water Hardness - 450 ppm).the plant
for soft water in a period of 10 hours operation for following OBR with
3 necessary accessories complete with frontal piping,valves,suitable Set 1.00
supports for mounting pressure gauges,orifice plates. The filter shall be
made of FRP with necessary accessories. The cost of filter shall also
include initial charge of media to suit the requirement etc.complete as
per standards.

Capacity :7.5 Cum/Hour @ 75 Cum OBR(Output Between Regenaration)

One vertical cylindrical pressure filter with dished ends made of Fibre
with suitable nozzles and manhole.
Design Pressure: 3 Kg per Cm2
Filter Media: acidic cation exchanger , One Charge
Pressure guages to indicate loss of head (Which indicates when back
wash is necessary)
Floating message for operation and regeneration as
Multiport valve with necessary accessories etc,complete and the scope
includes Brine solution tank with necessary connections.
Size of the Vessel : As per Manufacture Standard sizes

Supply, installation, Testing & commissioning of Pressure Sand Filter


with necessary accessories complete with frontal piping,valves,suitable
4 supports for mounting pressure gauges,orifice plates. The filter shall be Set 1.00
made of FRP with necessary accessories. The cost of filter shall also
include initial charge of under bed with pebbles & Coarse Sand media to
suit the requirement etc.complete as per standards.

Capacity :7.5 Cum/Hour @ 75 Cum OBR(Output Between Regenaration)

For Employer Page 25 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0
One vertical cylindrical pressure filter with dished ends made of Fibre
with suitable nozzles and manhole.
Design Pressure: 3 Kg per Cm2
Filter Media: Coarse Sand , Capacity : One Charge
Pressure guages to indicate loss of head (Which indicates when back
wash is necessary)
Floating message for operation and regeneration as
Multiport valve with necessary accessories etc,complete .
Size of the Vessel : As per Manufacture Standard sizes

Supply, installation, Testing & commissioning of Activated Carbon


Filter with necessary accessories complete with frontal
piping,valves,suitable supports for mounting pressure gauges,orifice
5 plates. The filter shall be made of FRP with necessary accessories. The Set 1.00
cost of filter shall also include initial charge of under bed with pebbles
& Activated carbon filter media to suit the requirement etc.complete as
per standards.

Capacity :7.5 Cum/Hour @ 75 Cum OBR(Output Between Regenaration)

One vertical cylindrical pressure filter with dished ends made of Fibre
with suitable nozzles and manhole.
Design Pressure: 3 Kg per Cm2
Filter Media: Activated Carbon Capacity : One Charge
Pressure guages to indicate loss of head (Which indicates when back
wash is necessary)
Floating message for operation and regeneration as
Multiport valve with necessary accessories etc,complete .
Size of the Vessel : As per Manufacture Standard sizes

For Employer Page 26 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supply of Vertical Multi stage Centrifugal Pump with suitable capacity


415V, 3-phase,50Hz motor and coupling with base frame having
discharge capacity of 7.5 Cum/Hr against total head of 35m from all
6 causes, with starter consists of suitable MPCB, Cont actor, Overload Set 1.00
relay, Single Phase Prevent or, Push buttons, LED on indicators, all in
comings in Weather Proof box and necessary suitable copper cables
from starter panel to pump etc., complete as required.

Pump Capacity : 7.5 Cum/Hour @ 35 meter Head


No of pumps : 1Working + 1 Stand by
Suction : Negative (3.0 meter)

Supply, installation, Testing & commissioning of UV - sterilization


7 plant .The plant consists of Rinsing set for UV-disinfection plants for URO
cleaning of deposits on quartz and internal surface of protective tube.

Flow Capacity : 7.5 Cum/Hour

Supply,Installation ,Testing & Commissioning approved make Electronic


dosing system for dosing Hypo chlorite solution or any other
equivalent to the bio medical waste with pre-set dosage based on the
8 quantity of water.The dosing system shall consist of Electronic dosing Set 1.00
pump with positive displacement type with adjustable stroke length and
frequency.The quoted rate shall also include FRP chemical solution
tank,necessary electricals etc.complete to make the operation
automatic.

Max.Working Pressure = 3.0 Kg/SqCm


Max.Flow Rate = 1 Litre/Hr @ 20 Hr Cycle

For Employer Page 27 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supply,Installation ,Testing & Commissioning approved make Electronic


dosing system for dosing residual chlorine to the stp treated water at
terrace over head tank with pre-set dosage based on the quantity of
9 water.The dosing system shall consist of Electronic dosing pump with Set 1.00
positive displacement type with adjustable stroke length and
frequency.The quoted rate shall also include FRP chemical solution
tank,necessary electricals etc.complete to make the operation
automatic.

Max.Working Pressure = 3.0 Kg/SqCm


Max.Flow Rate = 1 Litre/Hr @ 20 Hr Cycle

Providing, laying, jointing, fixing, testing & commissioning of piping


sytem with UPVC SCH-40 pipes fittings,required valves and instruments
for processing in treatment plant. The scope includes cutting the pipes
10 to required lengths, jointing the pipes using solvent joint type. And Lot 1.00
necessary chasing the walls / floors, making holes, clamping to walls
and restoring the same to original conditions etc., complete all as
specified and directed and as per manufacturer's specification.

TOTAL FOR WATER TREATMENT PLANT WORKS


G HOT WATER SYSTEM

For Employer Page 28 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supply ,Installation, testing and commissioning of Solar water heater


comprising of solar collectors, storage tank, associated piping and
controls. The collectors shall consists of 1.4mm thick Aluminum
collector frame, toughened clear glass for covering, 50mm Rock wool
Insulation for bottom & 25mm insulation for sides. The absorber plate
shall be of 36 SWG copper & NaLSUN coating. Reflective foil of 0.05mm
thick & Grommet is of EPDM, riser & inlet shall be of copper. The
collector size shall be 2080mm x 1070mm x 100mm. & the absorber
1 area is 2 Sq.Mt. 9 No. of riser tubes & absorber plate per collector with
88% glazing transmitivity. The coating absorptivity is 0.95 & coating
emissivity is 0.16. The absorber riser bonding shall be continuous
bonding. The storage tank shall be SS 304 grade(Wall Thickness of the
tank shall be 3.0mm) with built in thermostat ,auto air vent & drain
valves to be provided for the system, insulation of the tank shall be of
Rock wool with Aluminum cladding material. Necessary valves &
internal piping shall be made, with ISI fittings or equivalent as directed
by the Engineer-in -charge.

Capacity : 2000 Ltr Set 2.00


Supplying,installing,testing and commissioning approved make cast
2 brass body Digital water meter with necessary unions,valves for fixing
on the cold water main ,etc., complete
a) 32 mm nominal dia No 1.00
Supplying,installing,testing and commissioning approved make cast
3 brass body Digital water meter with necessary unions,valves for fixing
on the Hot water main ,etc., complete .
a) 25 mm nominal dia No 1.00

For Employer Page 29 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supply ,intallation,testing & commissioining of of Air Source Water


Heating System including the necessary accessories and safeties and
capable of delivering hot water at 60 Deg.C.The scope includes
4 automatic control panel microprocessor controller along with
necessary accessories. Please refer specifcations for rated input &
output capacities.

Heat Pump Capacity:750 Ltrs / Hour No 2.00

Supply ,installation & testing of MS fabricated floor supported


Horizontal type/ Vertical type storage tank ,internally lined with SS with
an adequate wall thickness, fabrication with dish ends and 500mm of
top manhole with pad plates .It consists of Solar water Input &
Output,Incoming connections for Re Circulation Water , thermostat
,auto air vent & drain valves to be provided for the system.Tank shall be
insulated with 100 mm thick rock wool insulation of 48 kg/cu.m.
density having approx. k value_0.03 W/mk and R value 3.34 sq.m
deg.C/W to withstand a temp. of 250deg.c.Thin polythene sheet
shall be used as covering between the glass wool and the cladding
5 sheet besides the retaining material such as chicken mesh etc.
Aluminum sheet of thickness 24 SWG shall be used for cladding the
tank insulation. The storage tank shall be properly installed at site
using enameled coated appropriate size angle iron stands, girder,
cement concrete pedestals of 1:2:3 ratio or any other specific
provision suitable to site.To ensure the stability against heavy
storm etc. but not less than 1’x1’x6” dimensions. External of
the tank should be properly insulated so that hot water
temperature does not decrease by more than 5 deg.C in about
16 hrs. Times. Necessary valves & internal piping shall be made, with ISI
fittings or equivalent as directed by the Engineer-in -charge.

Capacity : 4,000 Ltrs Set 1.00

For Employer Page 30 of 54 For Contractor


Project : Expansion of Yashoda Hospital- Phase-1
Client:Yashoda Hospitals Package: Supply,Installation,Testing and Commissioning of Internal and External
Architect: SMJ Design Inc Plumbing Works
PMC: KP Management Associates
MEP Consultant: Synergy Infra Consultant Pvt Ltd
BOQ
Interior Consultant: M/s. Prasad Badle Architects
Location: Somajiguda-Hyderabad Date: 28-Aug-2013 Rev: R0

Supply, delivery, testing, commissioning of Hot Water distribution


pump with suitable capacity 230V, 1-phase,50Hz motor and coupling
with base frame having discharge capacity of 5 Cum/Hr against total
6 head of 20m from all causes, without starter, complete as required. The Set 1.00
scope includes necessary pressure vessel & switch for auto on/off for
the pumps.

Each Pump capacity : 5.0 cu.m/Hr


No of Pumps : 1 working + 1 standby
Delivery head : 20 m
Pressure Vessel for Auto ON/OFF : 25 Ltrs Capacity
Supply, delivery, testing, commissioning of two stage centrifugal pump
with suitable capacity 230V, 1-phase,50Hz motor and coupling with
7 base frame having discharge capacity of 2.0 Cum/Hr against total head Set 1.00
of 15m from all causes, without starter, complete as required.(Hot
Water re-circulation pump).
Each Pump capacity : 2.0 cu.m/Hr
No of Pumps : 1 working + 1 standby
Delivery head : 15 m
Timer controller : 24Hours Operated
TOTAL FOR HOT WATER SYTEM
GRAND TOTAL

For Employer Page 31 of 54 For Contractor


FIRE FIGHTING WORKS

S.NO DESCRIPTION UNIT QTY Supply Instalation


1 Providing and fixing 63 mm dia (2.1/2”) N.B. hydrant Single headed oblique
landing Valve in SS Morris Pattern instanteous coupling type ISI certified
heavy type hydraulically tested to 250 psi working pressure with necessary
nuts, bolts Gaskets, GI chain twist release type plug. including fabricated tee Rmt 15 6200 300
connection, as per IS 5290

2 Supplying & fixing fire hydrant MS cabinet type shutter enclosure of following
size made up of 16 guage MS plate continuously welded on all edges or
fabricated with bends at all edges using single plate capable of
accommodating the 2 nos. 15 m fire hose And 1 nos.SS branch pipe.
Including railway coach lock up arrangement & lever for opening the door after
breaking the glass. Each hose box is to be fitted with front glass door painted
"FIRE" with red luminous paint. Hinges should be sturdy to bear the weight of
fully open door without sagging. Cabinet should be powder coated by
standard process on all sides with red paint of approved make suitable for
fixing to wall as directed by Architect (flush/surface mounted) etc. complete.
Contractor to get sample approved for workmanship from Architect.

a) )750mm wide x 400mm deep x 600mm Nos 15 3400 200


3 Supplying and fixing 63mm dia Hose pipe Reinforced Rubber lined as per
IS:636 type-A respectively with 15 M standard length including SS metal male
Nos 30 3000 200
and female Coupling duely bound with GI wire,etc. Complete As directed by
Architect in charge.

4 Supply and fixing of S.S. branch pipe with 63mm dia female inlet and male Nos 15 2000 100
threaded outlet with hexagonal based nozzle as per IS 903
5 Supplying & fixing first aid fire hosereel of Synthetic rubber suitably reinforced
Dunlop/NEWAGE/EQV make 20mm /25 MMsize & 30m standard length with
PVC nozzle with cut off valve attachment. Hose to be swinging type wall
mounted drum & recessing into hose cabinet to suit location including fixing Nos 14 6300 300
with lead anchor fasteners & bolts ( Incluiding drum and swivel arrangment )
etc complete.
6 Providing and fixing ball VALVE heavy quality fullway valves for isolation at 1200
inlet to hose reels (ISI certified make) etc. complete.
a) 25 mm dia Nos 14 1200 100
7 Supplying and fixing specially designed SS orifice plates on hydrant outlets of
landing valves including distant pieces of suitable size for adjustment of
delivery pressure of 3.5 kg/ sq.cm as required by LPA complete with necessary Nos 15 1200 200
companion flanges, nuts, bolts, gaskets etc. complete.

8 Supplying, installation testing and commissioning of the following (Class 'B')


MS pipes and fittings confirming to IS 1239 PI & II, with flanges welded
/welded joints) as required including pipe of shorter lengths, tapering
connecting pieces, short or long bends, specials like sockets, union nuts,
elbows, reducers, plugs, Tees etc.Complete to make the system operative as
required by local fire authorities. including welding, cutting, fixing in / on walls,
under ground etc., the pipes will have to be laid and fixed in trenches on walls,
ceilings, into brick walls or RCC with lead anchor fastners.The work includes
excavation in all types of soils and back filling and making holes in brick or
RCC walls, slabs/ roofs and making good the damages by bringing to the
original condition to the satisfaction of the Architect and painting two coats of
approved shade of enamel paint over a coat of approved primer.

a) 150mm dia Rmt 175 1150 450


b) 100mm dia Rmt 75 900 300

c) 80mm dia Rmt 50 750 250


d) 50mm dia Rmt 75 400 150
e) 25mm dia Rmt 50 275 75
9 Supplying, installation testing and commissioning Cast Iron Body Sluice valve
PN 1.6 Non-rising stem type conforming to IS:780, with flanged ends
17500
a) 100mm dia Nos 1 17500 500

SYNERGY infra CONSULTANTS PVT.LTD 1


FIRE FIGHTING WORKS

S.NO DESCRIPTION UNIT QTY Supply Instalation


10 Supplying, installation testing and commissioning C.I. Non-return valve
conforming to IS : 5312 with flanged ends (heavy) tested to 250 psi hydraulic
pressure with necessary companion flanges, bolts, nuts, gasket packing and
any other spares, including indicator for open ands hut position as per fire
practice etc complete.

a) 100mm dia Nos 1 17500 500


11 Supply and installation of CI Butterfly valves (heavy) tested to 250 psi
hydraulic pressure with Vertical/horizontal gear unit with appropriate handle
conforming to IS:13039 with necessary companion flanges, neoprene gaskets
with necessary companion flanges, bolts, nuts, gasket packing and any other
spares, including indicator for open and Shut position as per fire practice etc
complete.
a) 150mm dia Nos 2 7000 500
12 Supply, installation, testing & commissioning of Gun metal Air release valve Nos 2 2300 200
with ball valve - 25mm dia

13 Supply installation and fixing of flow switches in the following Pipe line with
1NO+1NC Contacts

a)80mm dia Nos 14 5300 200

14 Supply and installation, and fixing of 1.1KV PVC XLPE insulated cables of
copper conductor with double compression type cable gland and heavy duty
tinned copper cable sockets as per the relevant IS standards. Rate shall be
inclusive of all sundry materials like adhesive tape , PVC sleeves , bolts
and nuts, washers etc. including plugging unused holes.

a) 3C x 1.5.sqmm Rmt 2500 55 10


15 Supply, installation, testing & commissioning of 16 WINDOW ANNUNCIATION NOS 1 24000 1000
PANEL FOR FIRE INDICATION from flow switch

TOTAL RATE

II FIRE HYDRANT INSTALLATION (EXTERNAL)

1 Providing and fixing 63 mm dia (2.1/2”) N.B. hydrant single headed oblique
landing Valve in SS Morris Pattern instanteous coupling type ISI certified
heavy type hydraulically tested to 250 psi working pressure with necessary Nos 6 6300 200
nuts, bolts Gaskets, GI chain twist release type plug. including fabricated tee
connection, as per IS 908
2 Supplying & fixing fire hydrant MS cabinet type shutter enclosure of following
size made up of 16 guage MS plate continuously welded on all edges or
fabricated with bends at all edges using single plate capable of accomodating
the 2 nos. 15 m fire hose And 1 nos SS branch pipe. Including railway coach
lock up arrangement & lever for opening the door after breaking the glass.
Each hose box is to be fitted with front glass door painted "FIRE" with red
luminous paint. Hinges should be sturdy to bear the weight of fully open door
without sagging. Cabinet should be powder coated by standard process on all
sides with red paint of approved make suitable for fixing to wall as directed by
Architect (flush/surface mounted) etc. complete. Contractor to get sample
approved for workmanship from Architect.

a) )750mm wide x 250mm deep x 600mm Nos 6 3400 200


3 Supplying and fixing 63mm dia Hose pipe Reinforced Rubber lined as per
IS:636 Part-A respectively with 15 M standard length including SS metal male
Nos 12 3000 200
and female Coupling duely bound with GI wire,etc. Complete As directed by
Architect in charge.
4 Supply and fixing of S.S. branch pipe with 63mm dia female inlet and male Nos 6 2000 100
threaded outlet with hexagonal based nozzle as per IS 903

SYNERGY infra CONSULTANTS PVT.LTD 2


FIRE FIGHTING WORKS

S.NO DESCRIPTION UNIT QTY Supply Instalation


5 Supplying and fixing specially designed SS orifice plates on hydrant outlets of
landing valves including distant pieces of suitable size for adjustment of
delivery pressure of 3.5 kg/ sq.cm as required by LPA complete with necessary Nos 6 1200 200
companion flanges, nuts, bolts, gaskets etc. complete.

6 Supplying, installation testing and commissioning of the following (Class 'B')


MS pipes and fittings confirming to IS 1239 PI & II, with flanges welded
/welded joints) as required including pipe of shorter lengths, tapering
connecting pieces, short or long bends, specials like sockets, union nuts,
elbows, reducers, plugs, Tees etc.Complete to make the system operative as
required by local fire authorities. including welding, cutting, fixing in / on walls,
under ground etc., Underground piping with necessary flanges & fittings such
as elbows,tees and providing and fixing anchor blocks in PCC 1:2:4 at all
bends, tees, alongwith pipe coating and wrapping of underground pipes with
`PYPKOTE' 4mm thick conforming to IS : 10221. It includes providing and
fixing pypkote (corrosion protection tape) including supply and application of
pipe coating and spiral Wrapping (wrapping should have overlap of 15 to 20
mm) etc. complete as per ASTM standards for corrosion protection of pipes
that will be laid under the ground]

a) 150mm dia Rmt 150 1150 450


b) 100mm dia Rmt 35 900 300
c) 80mm dia Rmt 15 750 250
7 Supplying, installing and commissioning of fire brigade inlet connection
conforming to IS 5290 comprising of 2nos.SS 63mm dia instantaneous
Nos 1 21500 500
couplings complete with CI non-return valve, CI butterfly valve, connected to
150 mm dia Fire TANK FILLINGand fire hydrant wet riser pipe.
8 Supplying, installing and commissioning of fire brigade inlet connection
conforming to IS 5290 comprising of 4nos.SS 63mm dia instantaneous
Nos 1 27500 500
couplings complete with CI non-return valve, CI butterfly valve, connected to
150 mm dia forRING MAIN
9 Constructing masonry Chamber 1200x1200x1000 mm, inside with 75 class
designation brick work in cement mortar 1:6 ( 1 cement : 6 fine sand ) for
sluice valve, with C.I.surface box 100mm top diameter, 160mm bottom
diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4
mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10
graded stone aggregate 40mm nominal size) and inside plastering with
Nos 3 12500 1500
cement mortar 1:3 (1 cement : 3 coarse sand ) 12mm thick finished with a
floating coat of neat cement complete as per standard design including curing,
back filling of the chamber sides with the excavated soil, disposing of the
surplus earth after back filling with initial lead of 30 meters. Providing medium
duty cast iron frame and cover etc., complete. ( weight: 110kgs.) as per
specification.

10 Supply, installation, testing & commissioning of Cast Iron Body Sluice valve PN
1.6 Non-rising stem type conforming to IS:14846, with flanged ends

a) 150mm dia Nos 3 21500 500


11 Supply, installation, testing & commissioning of R.C.C NP2 class Hume pipe
laid to the required level and grade with collars jointed with in CM1:3.
Including encasing the pipe around a depth of not less than 15cm thick with
selected earth (fine aggregate) available from the excavation as per
specification and direction of the engineer. The excavated soil shall be
deposited on banks with all lead, lift, including necessary wooden/steel form
work where ever required. Depositing of the surplus earth after backfilling to a
initial lead of 30 meters. Refilling of the pipe line trenches and foundation with
selected earth available from the trench excavation including watering
consolidation in layers of 15cm thickness complete as per specifications. The
back fill soil shall be graded soil free from stones, pebbles, clay lumps and
vegetation etc., complete as per the specifications, and drawings.

SYNERGY infra CONSULTANTS PVT.LTD 3


FIRE FIGHTING WORKS

S.NO DESCRIPTION UNIT QTY Supply Instalation


a) 300mm dia Rmt 20 1200 200

12 Supply, installation, testing & commissioning of Gun metal Air release valve Nos 3 2300 200
with ball valve - 25mm dia

13 Supply and installation of CI Butterfly valves (heavy) tested to 250 psi


hydraulic pressure with Vertical/horizontal gear unit with appropriate handle
conforming to IS:13039 with necessary companion flanges, neoprene gaskets
with necessary companion flanges, bolts, nuts, gasket packing and any other
spares, including indicator for open and Shut position as per fire practice etc
complete.

a) 150mm dia Nos 3 7000 500


TOTAL RATE

III FIRE PUMP HOUSE


1 Supplying & installing completely testing & commissioning of electrically Driven
End suction and back pull out pump with cast iron casing & bronze or
phosphor bronze internal parts, for fire duty, complete with coupling guard
necessary RCC foundation,capable of discharging 2850 lt/min against 88
metre head at 8.8 bar against all losses complete electrically operated TEFC
3-ph, 440-V, 50 Hz, 2900 RPM motor of ‘F’ class winding, make as approved
by TAC with automatic direct on line starter complete with single phasing
preventor & No volt release as per LPA requirements common base plate,
foundation bolts, suitable cable entry gland box for A-AL cable (95 sq.mm) Nos 2 15000
pressure guages & wired for automatic start of the water pump on drop of
pressure in the wet riser/ hydrant and sprinkler system. The motor starter and
pump should confirm to LPA / BSES & and IE Regulations. The pump shall be
capable of giving not less than 150% discharge at a head not less than 65% of
the rated head.(Main Hydrant Pump and sprinkler)

2 Supplying & installation, testing & commissioning of End suction and back pull
out diesel engine driven pump of capacity 2850 Litr/Min, 88 Mtrs head
Common Standby pumpset for wetriser & sprinkler system at 8.8 Bar and 2900
rpm with all necessary accessories like bronze impeller, stainless steel shaft
and mechanical seal along with anti-vibration mounting, coupling, gear box,
base plate for pump, fabricated mild steel channel with foundation bolts etc.,
It includes providing and fixing fuel oil tank (capacity as perTAC
Nos 1 455000 20000
requirements) with supports and necessary pipe works for diesel engine,
battery and battery charger to be connected to control panel of diesel engine
and exhaust silencer including necessary pipe work insulation and cladding,
etc., and shall be automatic in operation with diesel engine control diesel
engine control panel with 24V DC storage battery & its battery charger. (diesel
engine)

3 Supplying, installing, testing and commissioning of electrical motor Driven


jockey pump for hydrant system with discharge 180 lpm against head 88 mtrs
Nos 1 95000 5000
at 8.8 bar with M.S. frame and clamps as necessary for fixing the pumps on
the foundation slab as per site conditions
4 Supplying, installing, testing and commissioning of electrical motor Driven
Booster pump for hydrant system with discharge 900 lpm against head 35 m
RO 1 45000 5000
with M.S. frame and clamps as necessary for fixing the pumps on tthe
foundation of slab as per site conditions

SYNERGY infra CONSULTANTS PVT.LTD 4


FIRE FIGHTING WORKS

S.NO DESCRIPTION UNIT QTY Supply Instalation


5 Supply, Installation, Testing and Commissioning of Indoor / outdoor,
weatherproof 3 phase 415V 4 wire Free Standing Floor mounted MV panel
made out of 14 SWG CRCA sheet after seven tank process and painting with
Epoxy powder coating including all switchgear as detailed below. The panel
shall consist of suitable rating TPN Aluminium/Copper busbar (at the rating of
0.8A/Sq.mm/1.6A/sq.mm) supported with DMC/ SMC barriers and colour
coded with Heat shrinkable sleeves.The Metering shall be provided as
specified. The panel shall have Short circuit with standing capacity of minimum
50KA and consist of the switchgear as mentioned below. The panel shall be
mounted on channels grouted to the existing floor including all materials. The
panel shall be got fabricated from manufacturers with CPRI Test certificate
only. All the PCC/ Panels shall have at least two spare cubicles of the
maximum rating. All feeders shall be earthed with 2 GI flats of adequate size to
the main earth bus of 50x6mm GI flat. The size of all Panel Mounting Meters
shall be 96X96mm.The Panels shall be mounted on U channels including
supply and fixing of the same.All MCCBs shall have 80-100% thermal setting
plug. MCBs shall be provided for Control purposes.

Supply, installation, testing and commissioning of electrical control panel diesel


engine main motor and jockey pump, comprising of following. All contactors
shall have status feed back provision to BMS.

Incoming – 400A,50KA FP MCCB -1set


(with Mechanical interlocking between incommers and Bus couplers)
Busbars : 400A TPN aluminium BUSBARS- 1SET

Outgoings : (1) DOL starter with MCCB and contactor, over load relay,single
phasing preventor and ON/OFF/TRIPindication lamps for motor -2sets

(2) DOL starter same as above for 15HP motor - 1set

(3) 63A , TPN MCCB for terrace booster pump - 1 Set

(4) 32A, TPN MCB feeder for Engine control panel-1 Set

Metering ; Voltmeter, Ammeter, LED phase Indication lamps, Ammeters for


both outgoings The Rate shall include supply and fixing of all The Rate shall
Nos 1 220000 5000
include supply and fixing control devices for auto operation of pump of all
motors
6 Supply, installation, testing and commissioning of weather proof type starter
consisting of following and made of 2mm thick CRCA sheet including painting
with epoxy powder coating for 15HP Booster pump motor. The box shall be
suitable for terminating AYFY cable of 3core 6sq.mm size. The box shall be
mounted on suitable angle frame work of 450mm height on a PCC pedestal
including all materials. The stater shall have status feed back provision to BMS

DOL starter suitable for 15HP with MPCB and contactor, over load relay, single
phasing preventor and ON/OFF/TRIP indication A/M selection switch & push
RO 1 13000 2000
button for manual operations and with volt meter,Ammeter with selector
switches
7 Supplying, installation testing and commissioning of the following (Class 'B')
MS pipes and fittings confirming to IS 1239 PI & II. The pipes complete with
necessary specials such as tees, bends, flanges, reducers, etc. Rate quoted
shall include for painting of pipe with a coat of primer and two coats of
synthetic enamel paint of approved colour / make for aboveground piping and
coating & wrapping for under ground piping as per the TAC / IS standards and
Local fire service department requirement complete including supply and
installation of pipe supports, fasteners etc.,

Above ground piping with necessary flanges & fittings such as elbows, tees
and Painting, supports and Orifice plates if any necessary for the fire
protection system complete as per the requirement of Local fire service
department.

SYNERGY infra CONSULTANTS PVT.LTD 5


FIRE FIGHTING WORKS

S.NO DESCRIPTION UNIT QTY Supply Instalation


a) 200mm dia Rmt 30 1400 600
b) 150mm dia Rmt 20 1150 450
c) 100 mm dia Rmt 15 900 300
d) 80 mm dia Rmt 15 750 250
e) 50 mm dia Rmt 25 400 150
f) 25 mm dia Rmt 30 275 75
8 Supplying, installation testing and commissioning Cast Iron Body Sluice valve
PN 1.6 Non-rising stem type conforming to IS:780, with flanged ends

a) 200mm dia Nos 4 27500 500


b) 150 mm dia Nos 4 21500 500
c) 100mm dia Nos 1 17500 500
d) 80mm dia Nos 1 14500 500
9 Supplying, installation testing and commissioning C.I. Non-return valve
conforming to IS : 5312 with flanged ends (heavy) tested to 250 psi hydraulic
pressure with necessary companion flanges, bolts, nuts, gasket packing and
any other spares, including indicator for open ands hut position as per fire
practice etc complete.

a) 200mm dia Nos 1 27500 500


b) 150mm dia Nos 3 21500 500
c) 80mm dia Nos 1 17500 500
10 Supplying, installation testing and commissioning Foot valve/strainer with
Flanged ends.

a) 200mm dia Nos 3 31500 500


b) 100mm dia Nos 1 17500 500
11 Supplying, installation testing and commissioning of G.M. gate valves
conforming to IS 778

a) 25 mm dia Nos 5 2400 100


12 Supplying, installation testing and commissioning of G.M. Non-return valves
conforming to IS 778

a) 25mm dia Nos 5 2400 100


13 Supplying and fixing MS fabricated air vessel at pump room about 250mm dia
and 1500mm high on MS stand with necessary cut off drain and air release
arrangements and leading the drain pipe to the sump at pump room with
painting with red oxide primer and finished with fire red enamel paint. It shall
be inclusive of all relevant pipes, valves, specials upto pump header and other Nos 1 12500 1500
accessories as per Local fire service department standard / requirement.
including TAC approved pressure gauge with cork and of suitable range as for
Providing required pressure etc. complete.

14 Supplying, installation testing and commissioning of Pressure gauge (0-14


Kg./sqcm) of 100 mm dia Dial size with required fittings and accessories Nos 10 2200 100

15 Supplying, installation testing and commissioning of Pressure switch (0-15 Nos 5 4500 200
Kg./sqcm) with required fittings and accessories
16 Supply fabrication and erection of MS angle supports for Pipe lines Ton 1 60000 5000
17 Supplying, installation testing and commissioning of End termination for
1.1KV cables with double compression type cable gland and heavy duty
tinned copper cable sockets as per the relevant IS standards. Rate shall be
inclusive of all sundry materials like adhesive tape , PVC sleeves , bolts
and nuts, washers etc. including plugging unused holes.

a) 3C x 120.sqmm AYFY cable ( to main pump ) Rmt 60


b) 4C x .16sqmm AYFY cable ( for jockey pump & booster pumps) Rmt 25

c) 3C x 1.5.sqmm copper control cable ( To Pressure switches controllers) Rmt 75

SYNERGY infra CONSULTANTS PVT.LTD 6


FIRE FIGHTING WORKS

S.NO DESCRIPTION UNIT QTY Supply Instalation


18 Supply, fixing, testing and commissioning & installation of alarm gong valve
assemble contains of 1-no. Alarm valve, 1 no. Main stop valve, 1 no. water
meter with alarm gong, Pressure guage drain valve and drain piping etc.,

a) 150mm dia Set 1


19 Supply and installation of GI Perforated cable trays of following sizes made out
of 2mm thick GI sheet including all supports as required

a)300mmX50mm Rmt 60
20 Supply and laying of following size hot dip galvanized GI strips to run along
with cable trays for erathing of all motors

a)50X6mm GI strip Rmt 30


b)25X3mm GI strip Rmt 30
c) 8SWG GI Wire Rmt 10
21 Supplying, installation testing and commissioning priming HDPE tank (Sintex)
of 500Ltrs capacity at required level including MS angle supports, with
Nos 1
inlet,outlet,overflow & drain pipes including controlling valves,welding of
supports bolts and nuts etc., complete accessories
TOTAL

IV AUTOMATIC SPRINKLER SYSTEM.

1 Supply and installation, Providing and fixing approved make 15mm orifice
quartzoid bulb type sprinklers, 68°C rating, recessed pendent type with roset
Nos 700
plate (adjustable) off white finish wherever required and all accessories,
supports and painting etc.
2 Supply and installation, Providing and fixing approved make 15mm orifice
quartzoid bulb type sprinklers, 68°C rating, recessed wall mounted type with
Nos 100
roset plate (SINGLE ) off white finish wherever required and all accessories,
supports and painting etc.
3 Supply and installation, testing and commissioning of Sprinkler flexible Pipe Nos 250
required length of 1.5M including angles and supports
4 Supply and installation of CI Butterfly valves (heavy) tested to 250 psi
hydraulic pressure with Vertical/horizontal gear unit with appropriate handle
conforming to IS:13039 with necessary companion flanges, neoprene gaskets
with necessary companion flanges, bolts, nuts, gasket packing and any other
spares, including indicator for open ands hut position as per fire practice etc
complete.

a) 100mm dia Nos 10


b) 80mm dia Nos 4
c) 50mm dia Nos 4
5 Supplying, installation testing and commissioning of the following (Class 'B')
MS pipes and fittings confirming to IS 1239 PI & II, The pipes complete with
necessary specials such as tees, bends, flanges, reducers, etc. Rate quoted
shall include for painting of pipe with a coat of primer and two coats of
synthetic enamel paint of approved colour / make for aboveground piping and
coating & wrapping for under ground piping as per the TAC / IS standards and
Local fire service department requirement complete including supply and
installation of pipe supports from column/wall or suspenders from roof slab to
suit various dia of pipes made out of GI adjustable rods threaded for a
sufficient length to adjust the height of support along with clamping
arrangement for holding pipes of anchor fastening arrangement design of
hanger and should confirm to specification as indicated NFPA 13. etc.,

Above ground piping with necessary flanges & fittings such as elbows, tees
and Painting, supports and Orifice plates if any necessary for the fire
protection system complete as per the requirement of Local fire service
department.

a) 150 mm dia

SYNERGY infra CONSULTANTS PVT.LTD 7


FIRE FIGHTING WORKS

S.NO DESCRIPTION UNIT QTY Supply Instalation


Supply Rmt
installation Rmt
b) 100mm dia
Supply Rmt
installation Rmt
c) 80mm dia
Supply Rmt
installation Rmt
d) 65mm dia
Supply Rmt
installation Rmt
e) 50 mm dia
Supply Rmt
installation Rmt
f) 40 mm dia.
Supply Rmt
installation Rmt
g) 32 mm dia
Supply Rmt
installation Rmt
h) 25 mm dia
Supply Rmt
installation Rmt

6 Supplying, installation testing and commissioning of the CPVC pipes as per


IS:16088
Above ground piping with necessary flanges & fittings such as elbows, tees
and supports and Orifice plates if any necessary for the fire protection system
complete as per the requirement of Local fire service department.

a)50 mm dia Rmt 60


b)40 mm dia Rmt 30
c)25 mm dia Rmt 120
7 Supply installation and fixing of flow switches in the following Pipe line with
1NO+1NC Contacts

a)100mm dia Nos 10


b)80mm dia Nos 4

8 Supplying, fixing and testing approved make gun metal ball valve conforming
to IS 778 with unions etc., complete as per specifications.
a) 50 mm dia No 14
a) 25 mm dia No 4
9 Supply and installation, and fixing of 1.1KV PVC XLPE insulated cables of
copper conductor with double compression type cable gland and heavy duty
tinned copper cable sockets as per the relevant IS standards. Rate shall be
inclusive of all sundry materials like adhesive tape , PVC sleeves , bolts
and nuts, washers etc. including plugging unused holes.
a) 3C x 1.5.sqmm Rmt 2500
10 Supply, installation, testing & commissioning of 16 WINDOW ANNUNCIATION NOS 1
PANEL FOR FIRE INDICATION from flow switch
TOTAL
V WATER CURTAIN SYSTEM.

SYNERGY infra CONSULTANTS PVT.LTD 8


FIRE FIGHTING WORKS

S.NO DESCRIPTION UNIT QTY Supply Instalation


1 Supplying, installation testing and commissioning of the following (Class 'C') GI
pipes and fittings confirming to IS 1239 PI & II, for water curtain system . The
pipes complete with necessary specials such as tees, bends, flanges,
reducers, etc. Rate quoted shall include for painting of pipe with a coat of
primer and two coats of synthetic enamel paint of approved colour / make for
aboveground piping and coating & wrapping for under ground piping as per the
TAC / IS standards and Local fire service department requirement complete
including supply and installation of pipe supports from column/wall or
suspenders from roof slab to suit various dia of pipes made out of GI
adjustable rods threaded for a sufficient length to adjust the height of support
along with clamping arrangement for holding pipes of anchor fastening
arrangement design of hanger and should confirm to specification as indicated
NFPA 13. etc.,

Above ground piping with necessary flanges & fittings such as elbows, tees
and Painting, supports and Orifice plates if any necessary for the fire
protection system complete as per the requirement of Local fire service
department.
a) 80mm dia Rmt 300
2 Supply,installation,testing and commissioning of Motorized Butterfly valve with
actuator for Water curtains with electrical motors suitable for 220V, Single
Phase 50Hz AC supply operation

a) 80mm dia Nos 5

3 Supply and installation, of control panel for water curtain motor consisting of
suitable relay MPCB ,DOL starter with contactor , over load relay, auto/manual
Nos 5
switch ,push buttons in manual mode and ON/OFF trip indicators all prewired

4 Supply,installation,testing and commissioning of 15mm Dia open type water Nos 120
curtain nozzles with k-factor of 25-32.
5 Supplying, installation testing and commissioning of End termination for
1.1KV cables with double compression type cable gland and heavy duty
tinned copper cable sockets as per the relevant IS standards. Rate shall be
inclusive of all sundry materials like adhesive tape , PVC sleeves , bolts
and nuts, washers etc. including plugging unused holes.

c) 3C x 2.5.sqmm copper control cable ( To motorized butterfly valve to Rmt 1500


panel)

TOTAL

SYNERGY infra CONSULTANTS PVT.LTD 9


FIRE FIGHTING WORKS

S.NO DESCRIPTION UNIT QTY Supply Instalation

VI ADDRESSABLE FIRE ALARM SYSTEM

Supply, fixing, testing and commissioning of the following number of Loops


Microprocessor based analogue addressable type Fire Control panel with
1 Zonal Indications , The system should have BMS compatibility, The system
shall have a built-in relay & Hooter to initiate failure of FACP.

6 Loop fire alarm panel (with each loop supporting 125 Detectors & Devices). No 1
1.1
Supply testing and laying of PVC insulated, 1.5sq.mm shielded armoured
2 twisted pair copper cable including all fixing accessories when laid inside the Mtr 4500
building including complete with end terminations at both sides.
Supply installation testing and commissioning of analogue addressable type
Multi (smoke& Heat ) photo electric detectors with LED indication lamp and
3 No 325
with in built fault isolator.(Below false ceiling) with complete fixing accessories.

Supply installation testing and commissioning of analogue addressable type


Multi (smoke& Heat ) photo electric detectors with LED indication lamp and
4 No 325
with in built fault isolator.(Above false ceiling) with complete fixing accessories.

Supply installation testing and commissioning of response indicators with all No 325
5
fixing accessories
Supply installation testing and commissioning of Loop sounders with all fixing No 18
6
materials.
Supply and installation of analogue addressable type Manual call points with No 18
7
Glass, hammer and monitor module and fixing accessories
9 Supply and fixing of Exit Light fixtures with 1.5hrs battery backup No 22

Supply installation testing and commissioning of analogue addressable type No 30


10
monitor modules for monitoring the sprinkler flow switches

Supply installation testing and commissioning of analogue addressable type


11 control relay / control modules for AHUS, Electrical circuit tripping, and PA No 20
amplifier activation in case of fire alarm.
12 Supply and fixing of duct detectors for AHU's at different levels. No 20
Supply, installation, testing and commissioning of intelligent Addressable
network control Active Repeater panel on FACP network configuration to
monitor and control all local fire alarm control panels with RS 485 port on CPU
13 board with optional network software connectivity, fire/ fault indicators, audio No 1
visual signals, battery, battery charger, central processing unit 80 character
display unit complete in all respects.
Supply, installation, testing and commissioning of Fire alarm management
software system and graphical display interface to network the installed fire
14 alarm panels using a network manager program and the following shall be
pre-equipped with :
a) Preparation of graphics compatible to fire alarm monitoring software of
buildings and connected with slave panels including layout of the building and
wiring diagram of the fire alarm system
b) Interconnecting the same with fire alarm software located at master panel
testing the parameters and operations of individual detectors and slave panels

c) Establishing two way communication with master panel and slave panels. No 1

A server based PC with 21” LCD monitor with 4 GB RAM loaded, 500GB
HDD , with per-loaded software's shall include UPS with 15 min backup and
15 RO 1
along with all fixing accessories. ( The above said item shall be in client
scope )
TOTAL

VII PUBLIC ADDRESS SYSTEM


S.NO DESCRIPTION

SYNERGY infra CONSULTANTS PVT.LTD 10


FIRE FIGHTING WORKS

S.NO DESCRIPTION UNIT QTY Supply Instalation


1 Supply and installation testing and commissioning of 6Watt 180mm dia
recessed/ surface mounted white color speakers (along with junction boxes to Nos 45
be used in no false ceiling area).
3 Supply and surface laying of 25mm dia heavy guage PVC conduits including Mtr 3000
all fixing accessories like saddles etc ( Shall be on actuals ).
4 Supply and laying of shielded twin twisted pair 1.0 sqmm cable in existing Mtr 3500
conduit ( Shall be on actuals ).
5 Supply installation testing and commissioning of 480 watts amplifiers Nos 1
complete with accessories
6 Supply installation and testing of GOOSE NECK MICROPHONE for Nos 1
announcement purpose.
TOTAL
VIII FIRE EXTINGUISHERS
1 Supply installation testing and commissioning of Water CO2 type Fire
Extinguisher of 9lit capacity, fitted with discharge control valve ( squeeze grip
type ) , inside STORED PRESSURE with ISI mark, with discharge hase and Nos 78
open nozzel overall conforming to IS: 15683 with ISI mark along with wall
bracket and initial refilling at site . Fire Rating 2A.
2 Supply installation testing and commissioning of CO2 type Fire Extinguisher of
4.5 kgs capacity made from brand new seamless drawn steel cylinder as per
IS : 7285 with ISI mark and Chief of controller of explosives approval, fitted
with wheel valve as per IS: 3224 with ISI mark, with discharge hose and horn Nos 78
and supplied complete with initial charge overall conforming to IS: 15683 with
ISI mark and wall bracket. Fire Rating 21B

3 Supply installation testing and commissioning of ABC Dry Chemical Powder


6.0 kg capacity fitted with discharge control valve ( squeeze grip type ), inside
STORED PRESSURE with ISI mark and ABC powder as per IS: 14609 ( for
ABC class ) with ISI mark packed in 6kgs HDPE bags, with discharge hose Nos 10
and open nozzel and supplied complete with initial charge overall conforming
to ISI: 15683 ISI mark and wall bracket . Fire Rating 3A.34B.

4 Supply installation testing and commissioning of Clean Agent Fire Nos 18


Extinguishers, 2.0 kg capacity
5 Sealing of Fire shafts at all floor levels by using M.S. angle Iron frame around
the shaft M.S. chequered plate and PCC of 1:2:4 (100mm thick) on the plate
Sq.ft 50 0
for whole shaft area as per drawings and engineer- in - charge.

21943
TOTAL Rs.

SYNERGY infra CONSULTANTS PVT.LTD 11


FIRE FIGHTING WORKS

AMOUNT

SYNERGY infra CONSULTANTS PVT.LTD 12


FIRE FIGHTING WORKS

AMOUNT

SYNERGY infra CONSULTANTS PVT.LTD 13


FIRE FIGHTING WORKS

AMOUNT

SYNERGY infra CONSULTANTS PVT.LTD 14


FIRE FIGHTING WORKS

AMOUNT

SYNERGY infra CONSULTANTS PVT.LTD 15


FIRE FIGHTING WORKS

AMOUNT

SYNERGY infra CONSULTANTS PVT.LTD 16


FIRE FIGHTING WORKS

AMOUNT

SYNERGY infra CONSULTANTS PVT.LTD 17


FIRE FIGHTING WORKS

AMOUNT

SYNERGY infra CONSULTANTS PVT.LTD 18


FIRE FIGHTING WORKS

AMOUNT

SYNERGY infra CONSULTANTS PVT.LTD 19


FIRE FIGHTING WORKS

AMOUNT

SYNERGY infra CONSULTANTS PVT.LTD 20


FIRE FIGHTING WORKS

AMOUNT

AMOUNT

SYNERGY infra CONSULTANTS PVT.LTD 21


FIRE FIGHTING WORKS

AMOUNT

SYNERGY infra CONSULTANTS PVT.LTD 22