Description: Technical data:
The EDS 3400 with IO-Link Input data
communication interface is a compact Measuring ranges 40; 100; 250; 400; 600 bar
electronic pressure switch with Overload range 80; 200; 500; 800; 1000 bar
integrated digital display for relative Burst pressures 200; 500; 1000; 2000, 2000 bar
pressure measurement in the high- Mechanical connection G1/4 A DIN 3852
pressure range. Threaded port DIN 3852-G1/4
The device is equipped with a switching Torque value 20 Nm
output and additional output that can be Parts in contact with medium Mech. connection: Stainless steel
configured as switching or analogue Sensor cell: Stainless steel
(4 .. 20 mA or 0 .. 10 V). Seal: FPM
Compared with the standard version, Output data
the IO-Link interface enables Output signals Output 1: PNP Transistor switching output
bidirectional communication between Output 2: can be configured as PNP transistor
the device and the control. switching output or analogue output
Parameterisation and cyclical Accuracy to DIN 16086 ≤ ± 0.5 % FS typ.
transmission of process and service Max. setting (display, analogue output) ≤ ± 1 % FS max.
data is therefore possible. Repeatability ≤ ± 0.25 % FS max.
The pressure switch series EDS 3400 Temperature drift ≤ ± 0.025 % FS / °C max. zero point
≤ ± 0.025 % FS / °C max. range
with communication interface IO-Link
Analogue output
according to specification V1.1 has
been specially designed for connecting Signal selectable: 4 .. 20 mA load resistance max. 500 Ω
0 .. 10 V load resistance min. 1 kΩ
sensors in automation systems.
Switch outputs
Typical fields of application are
machine tools, handling and assembly Type PNP transistor switching output
automation, intralogistics or the Switching current max. 250 mA per output
packaging industry. Switching cycles > 100 million
Reaction time < 10 ms
Long term drift ≤ ± 0.3 % FS typ. / year
Special features: Parameterisation Via IO-Link interface, with HYDAC
 1 PNP transistor switching output programming device HPG 3000 or push
 1 universal output, configurable buttons on the EDS 3400
as PNP transistor switching output or Environmental conditions
analogue output Compensated temperature range -10 .. +70 °C
 Accuracy ≤ ± 1 % FS Operating temperature range -25 .. +80 °C
Storage temperature range -40 .. +80 °C
 4-digit digital display
Fluid temperature range -25 .. +80 °C
 Optimum alignment: can be rotated in - mark EN 61000-6-1 / 2 / 3 / 4
two axes Vibration resistance according to ≤ 10 g
DIN EN 60068-2-6 (0 .. 500 Hz)
Shock resistance according to ≤ 50 g
DIN EN 60068-2-29 (11 ms)
Protection class to IEC 60529 IP 67
Other data
Supply voltage 9 .. 35 V DC without analogue output
18 .. 35 V DC with analogue output
Current consumption ≤ 0.535 A with active switching outputs
≤ 35 mA with inactive switching outputs
≤ 55 mA with inactive switching output
and analogue output
E 18.368.1.0/11.13

Display 4-digit, LED, 7-segment, red,


height of digits 7 mm
Weight ~ 120 g
Note: Excess voltage, override protection and short circuit protection are provided.
FS (Full Scale) = relative to complete measuring range

43
Setting options: IO-Link-specific data:
All terms and symbols used for setting the
EDS 3400 as well as the menu structure Baud rate 38.4 kBaud *
comply with the specifications in the Cycle time 2.5 ms
VDMA Standard for pressure switches. Process data width 16 Bit
Frame type 2.2
Setting ranges for the switch Specification V1.1
outputs: * Connection with unshielded standard sensor line possible
up to a max. line length of 20 m.
Measuring Lower limit of Upper limit of Download the IO Device Description (IODD) from:
range RP / FL SP / FH http://www.hydac.com/de-en/service/downloads-software-on-request/
in bar in bar in bar
0 .. 40 0.4 40.0
0 .. 100 1.0 100.0 Model code:
0 .. 250 2.5 250.0
0 .. 400 4 400
EDS 3 4 X 6 – L – XXXX – 000
0 .. 600 6 600 Mechanical connection
4 = G1/4 A DIN 3852 (male)
Measuring Min. difference Incre-
9 = Threaded port DIN 3852-G1/4
range betw. ment* Electrical connection
3 RP and SP 6 = Male M12x1, 4 pole
in bar & FL and FH in bar (connector not supplied)
0 .. 40 0.4 0.1 Output
0 .. 100 1.0 0.2 L = IO Link Interface
0 .. 250 2.5 0.5 Pressure ranges in bar
0 .. 400 4 1 0040; 0100; 0250; 0400; 0600
0 .. 600 6 1 Modification number
000 = Standard
* All ranges given in the table are
adjustable by the increments shown.
SP = switch point Notes:
RP = switch-back point On instruments with a different modification number, please read the label or the
FL = pressure window lower value technical amendment details supplied with the instrument.
FH = pressure window upper value Accessories:
Appropriate accessories, such as electrical connectors, mechanical adapters, splash
Additional functions: guards, clamps for wall-mounting etc can be found in the Accessories brochure.
 Switching mode of the switching outputs
adjustable (switching point function or
window function)
 Switching direction of the switching
outputs adjustable (N/C or N/O function) Dimensions: Ø 42
25.5 40.4
M12x1 11
 Switch-on and switch-off delay
adjustable from 0.00 .. 99.99 seconds
 Analogue output signal selectable: display turns
4 .. 20 mA or 0 .. 10 V thru 270°

 Pressure can be displayed in


16.1

bar, psi, MPa.


91.5

Pin connections:
64

75

housing turns
thru 340°
2 +0.1

M12x1, 4 pole
12

L+ hex. SW27
IO-Link G1/4 A DIN 3852-E
Ø 18.9 -0.2 16.1
1 C/Q
2 4 Ø 29.5
3
Elastomer profile gasket
DIN 3869
L- Standard IO Ø 53.5
I/Q

Pin Signal Description


1 L+ Supply voltage male elect. conn. M12x1
4 pole
2 I/Q Switching output (SP2) /
analogue output
3 L- Gnd
4 C/Q IO-Link communication /
Note:
switching output (SP1) The information in this brochure relates to
E 18.368.1.0/11.13

the operating conditions and


HYDAC electronic GmbH
applications described. Hauptstraße 27, D-66128 Saarbrücken
For applications or operating conditions Telephone +49 (0)6897 509-01
not described, please contact the relevant Fax +49 (0)6897 509-1726
technical department. E-mail: electronic@hydac.com
Subject to technical modifications. Internet: www.hydac.com

44

S-ar putea să vă placă și