Technical

Loads and ULS Load


combinations to the Eurocodes
In the language of the Eurocodes, ‘dead loads’ become ‘permanent actions’, imposed loads, snow loads and
wind loads are collectively called ‘variable actions’ and ‘load combinations’ becomes ‘combinations of actions’.
David Brown, SCI Deputy Director, explains the Eurocode system.

Actions little interest in steel design!


Actions are determined from the relevant part of BS The first Q represents the ‘leading’ variable
EN 1991 Actions on Structures, not forgetting that action, and is multiplied by a partial factor, γQ
designers will need to consult the National Annex Finally there are the ‘other’ variable actions,
for each part. BS EN 1991-1-1 covers densities, which are to be summed, factored by a partial
self weight and imposed loads – and will be used factor γQ but also multiplied by a combination
for such things as imposed loads on floors and factor, ψ0.
roofs – although note that snow loads may be Actions are combined so long as they do not
more onerous and are determined from a different serve to relieve the effect being considered.
Eurocode part. Reduction factors are available for The National Annex to BS EN 1990 must be
large areas of floors and when calculating the load consulted for the values of the partial factors γG and
in a column from several storeys. BS EN 1991-1-1 γQ and the combination factors ψ0. The combination
also gives quite detailed allowances for moveable factors, ψ0 depend on the type of load – so care
partitions, which are often accounted for in design. must be taken when extracting these from the
Snow loads are to be taken from BS EN National Annex. The UK partial factors for actions
1991-1-3 and wind loads from BS EN 1991-1-4. are shown below, with some typical ψ0 factors, all
Unfortunately, the National Annex to BS EN taken from the UK National Annex.
1991-1-4 Wind Actions is not yet published – it is
expected later in the year. For UK designers, this Partial Factor Permanent action, γG = 1.35
National Annex is very important as it presents Variable action, γQ = 1.5
some quite significant changes from the Eurocode. Combination factor Office areas, ψ0 = 0.7
Roofs, ψ0 = 0.7
Combinations of actions at ULS Snow loads (at lower altitudes), ψ0 = 0.5
BS EN 1990 Basis of Structural Design requires Wind loads, ψ0 = 0.5
that structures and members are designed for all
possible combinations of actions that can occur The second approach is to use the more onerous of
simultaneously. Fortunately for building designers, expressions 6.10a and 6.10b.
a note in clause A1.2.1(1) allows the maximum
number of variable actions to be limited to two.
∑ γ G, j Gk, j + γ P P + γ Q,1ψ 0,1Q k,1 + ∑ γ Q,iψ 0,iQk,i (6.10a)
Some judgement may need to be exercised in j ≥1 i ≥1

choosing which two variable actions to combine –


in doubt, alternatives should be considered. ∑ ξ j γ G, j Gk, j + γ P P + γ Q,1Qk,1 + ∑ γ Q,iψ 0,iQk,i (6.10b)

j ≥1 i ≥1
Four Ultimate Limit States are considered
relevant in BS EN 1990; EQU, STR GEO and FAT, The subtle attraction of this pair of expression
concerned with equilibrium, strength, ground and derives from two important changes from 6.10s:
fatigue. Mostly, designers will be concerned about • the application of the ψ0 factor to the leading
EQU when considering sliding or overturning, and variable action in expression 6.10a (not applied
STR for the strength of frames and members. in 6.10)
Two methods of determining the combination • The introduction of a reduction factor ξ applied
of actions are allowed for the STR Ultimate Limit to the permanent actions in expression 6.10b
States. In the UK, the National Annex allows either (not applied in 6.10)
approach. For good economic reasons, it is likely The value of the reduction factor ξ is given in the UK
that UK designers will adopt the second approach. National Annex to EN 1990 as 0.925. If considering
All loading expressions take some digesting. the EQU ULS, (sliding or overturning,) the use of
The first approach is to use expression 6.10. 6.10a and 610b is not allowed.

∑ γ G, j Gk, j + γ P P + γ Q,1Qk,1 + ∑ γ Q,iψ 0,iQk,i (6.10)


Example 1
j ≥1 i ≥1
The following numerical example examines the
G represents permanent actions. These are to be combination of actions for a floor beam, subject
summed and multiplied by a partial factor, γG only to permanent and variable actions.
P represents prestressing, and is probably of

30 NSC March 2008


Technical

Permanent action = 3.5 kN/m² Expression Permanent action Variable actions


Variable action (office) = 5 kN/m² Self-weight Imposed floor Wind
(6.10) γGj,sup = 1.35 γQ,1 = 1.5 γQ,i ψ0,i = 1.5 x 0.5
Using expression 6.10
= 0.75
3.5 × 1.35 + 5 × 1.5 = 12.23 kN/m²
Use 12.23 kN/m² γGj,sup = 1.35 γQ,i ψ0,i = 1.5 x 0.7 γQ,1 = 1.5
= 1.05
From expression 6.10a
3.5 × 1.35 + 5 × 1.5 × 0.7 = 9.98 kN/m² (6.10a) γGj,sup = 1.35 γQ,i ψ0,1 = 1.5 x 0.7 γQ,i ψ0,i = 1.5 x 0.5
From expression 6.10b = 1.05 = 0.75
3.5 × 1.35 × 0.925 + 5 × 1.5 = 11.87 kN/m²
γGj,sup = 1.35 γQ,i ψ0,i = 1.5 x 0.7 γQ,i ψ0,1 = 1.5 x 0.5
Use 11.87 kN/m² = 1.05 = 0.75
(6.10b) ξγGj,sup = 0.925 x 1.35 γQ,1 = 1.5 γQ,i ψ0,i = 1.5 x 0.5
Combination of actions including wind load
= 1.25 = 0.75
When members are subject to wind load in addition
to permanent and (for example) variable actions ξγGj,sup = 0.925 x 1.35 γQ,i ψ0,i = 1.5 x 0.7 γQ,1 = 1.5
= 1.25 = 1.05
from floor loads, the situation becomes slightly
more complex as both the imposed floor load Note that in Expression 6.10a, the results are
and the wind load can be considered, in turn, as identical whichever variable action is identified as
the leading variable action. The combinations the main accompanying variable action, because the
of actions are illustrated below. In each row, the UK National Annex specifies the same value for γQ,1
leading variable action is shaded. Pedantically, and γQ,i.
the shaded zones in expression 6.10a indicate
the ‘main accompanying variable action’ rather Example 2
than the ‘leading variable action’. When using the The use of expressions 6.10a and 6.10b is
expressions, each combination will have to be demonstrated in Figure 1 for a very simple bracing
considered – taking firstly one variable action as system shown with its unfactored vertical and wind
‘leading’ and then considering the combination with loads. The equivalent horizontal forces (EHF) must
the other variable action as ‘leading’. be calculated for each combination, because they
depend on the design (factored) vertical loads and

,ŸÃiÀʈÃÊ>ʏi>`ˆ˜}ʓ>˜Õv>VÌÕÀiÀÊ>˜`ÊÃÕ««ˆiÀʜvÊ
Vœ˜ÃiÀÛ>̈œ˜ÊiµÕˆ«“i˜ÌÊ̅>Ìʈ˜VÕ`iÃÊ>Õ̜“>̈VÊ
ŜÌÊL>Ã̈˜}]Ê«>ˆ˜Ìˆ˜}Ê>˜`Ê`Àވ˜}ÊÃÞÃÌi“ðÊ
"vviÀˆ˜}ʓœ`iÀ˜Ê>˜`ʈ˜˜œÛ>̈ÛiÊ܏Ṏœ˜ÃÊ,ŸÃiÀÊ
…>ÃÊÃÕ««ˆi`ʓ>˜Þʓ>œÀÊVœ“«>˜ˆiÃÊ̅ÀœÕ}…œÕÌÊ
̅iÊܜÀ`°
UÊ-…œÌÊ >ÃÌÊ UÊ
œ˜ÃiÀÛ>̈œ˜ÊÊ Ê
UÊ*>ˆ˜Ìˆ˜}Ê UÊ-ÕÀv>ViÊ*Ài«>À>̈œ˜Ê Ê
UÊ-iÀۈViÊ UÊ
œ˜ÃՏÌ>̈œ˜
vÌiÀÊÃ>iÃÊÃiÀۈVi]Êë>ÀiÊ«>ÀÌÃÊ>˜`ʓ>ˆ˜Ìi˜>˜ViÊ
«Àœ}À>““iÃÊ>ÀiÊ>ÃœÊ«ÀœÛˆ`i`Ê̅ÀœÕ}…ÊœÕÀÊ
Û>ÀˆœÕÃÊ`ˆÃÌÀˆLṎœ˜Ê«œˆ˜Ìð
-«iVˆ>ˆÃÌʈ˜Ê܏Ûi˜ÌÊ̜ÊÜ>ÌiÀÊL>Ãi`Ê
Vœ˜ÛiÀȜ˜Ã°
œÀʓœÀiʈ˜vœÀ“>̈œ˜Ê«i>ÃiÊVœ˜Ì>VÌÊÊ Ê
*>ՏÊ,>܏ˆ˜Ãœ˜ÊœÀÊ>Þ`˜ÊˆÌV…i˜°

,ŸÃiÀÊ1

1˜ˆÌÞÊÀœÛi]Ê-V…œœÊ>˜i
˜œÜÏiÞÊ ÕȘiÃÃÊ*>ÀŽ
*ÀiÃVœÌ]ÊiÀÃiÞÈ`i]ÊÎ{ʙ/

/i\Êʳ{{Ê­ä®Ê£x£Ê{nÓÊä{{{
>Ý\ʳ{{Ê­ä®Ê£x£Ê{nÓÊ{{ää
“>ˆ\ÊÀœÃiÀJÀœÃiÀՎ°Vœ“
7iLÈÌi\ÊÜÜÜ°ÀœÃiÀՎ°Vœ“

32 NSC March 2008


www.rlsd.com
will be simply taken as 1/200 of the total
vertical load. The partial, combination
and reduction factors are taken from
the table above. In Figure 2, the design
values are shown using expression
6.10b, with the imposed floor load as
the leading variable action. In Figure
Figure 1 Unfactored actions
3, expression 6.10b is again used, but
with the wind as the leading variable
action. For completeness, and because
the design must be based on the most
onerous of expression 6.10a and 6.10b,
the design values using expression
6.10a are shown in Figure 4.

Trust is everything
Figure 2 Design values, 6.10b, In this example, the maximum
imposed floor load ‘leading’ design force in the bracing member is
determined from expression 6.10b with
wind as the leading variable action.
The maximum axial load in the column
is also determined from expression
6.10b, but with the imposed floor load
as the leading variable action. This
Figure 3 Design values, 6.10b, however is a very simple example – • 60+ years’ experience supplying
wind load ‘leading’ and it would be easy to conceive a
structure where the results were not so structural flooring products
straightforward. In general, all possible
design combinations of actions must • A reputation for industry ‘firsts’
be checked.
For designers, the simplest solution
is to use expression 6.10, which will • Proven on some of the world’s
Figure 4 Design values, 6.10a
be conservative. If more economy is most prestigious projects
required, the use of expressions 6.10a
and 6.10b will be beneficial.

Comparisons with BS 5950.


For members subject only to vertical loading – usually the vast
majority of members in a structure, there is an obvious attraction
in the Eurocode design combinations. Instead of the design load
Capability. Innovation. Knowledge. It’s strengths like these
being based on 1.4 × dead + 1.6 × imposed, the load may be based
that make Richard Lees Steel Decking such a powerful choice.
on the more onerous of expression 6.10a or 6.10b. Unless the
permanent action is greater than the variable action by a factor And enable us to create such a positive, dependable
of 4.5 (quite an unusual situation!) expression 6.10b will be more difference to your structural flooring projects. For more
onerous, and the result will be a design based on 1.25 × dead + 1.5 products, more experience and more reassurance, talk to
× imposed load. With typical loads of (say) 3.5kN/m² permanent Richard Lees Steel Decking. It’s everything you need.
and 5 kN/m² variable, this represents a reduction in design loads of
8%. If the imposed floor loads are storage loads, expression 6.10b
will not necessarily be the more onerous, because a different ψ0
factor is applied.
The lateral design loads according to the Eurocodes will
increase compared to BS 5950. The maximum design loads are
based on a partial factor of 1.5 in the Eurocode system, rather than
1.4 in BS 5950. This will affect all the systems (bracing or moment-
resisting frames), that provide stability. In addition, the EHF appear
in all load combinations, and will increase the lateral loads still
further by a modest amount, compared to BS 5950 when the
wind loads alone were usually the dominant load combination for
bracing design.

Further Help Richard Lees Steel Decking Ltd


A host of SCI design guides are to be published through 2008. Moor Farm Road West, The Airfield, Ashbourne,
Loading is explained in the Introduction to Eurocodes (P361). Derbyshire DE6 1HD, UK.
Examples of loading are covered in worked examples for students Tel: +44 (0) 1335 300 999 | Fax: +44 (0) 1335 300 888
(P376), and in a guide covering the design of multi-storey braced Email: rlsd.decks@skanska.co.uk
frames (P365). Also in 2008, BCSA are to publish a Guide to
Eurocode Load Combinations for Steel Structures.

NSC March 2008 33

S-ar putea să vă placă și