KBPC6005

Shanghai Lunsure Electronic


Technology Co.,Ltd
Tel:0086-21-37185008
THRU
Fax:0086-21-57152769
KBPC610

Features 6 Amp Single Phase


• Plastic Case
• Low Forward Voltage Bridge Rectifier
• Any Mounting Position
• Silver Plated Copper Leads 50 to 1000 Volts
• Surge Overload Rating Of 150 Amps

BR-6
Maximum Ratings
• Operating Temperature: -55°C to +125°C
• Storage Temperature: -55°C to +150°C B

Device Maximum Maximum Maximum


Catalog Marking Recurrent RMS DC
Number Peak Reverse Voltage Blocking C
Voltage Voltage
KBPC6005 BR6005 50V 35V 50V
KBPC601 BR601 100V 70V 100V
KBPC602 BR602 200V 140V 200V
KBPC604 BR604 400V 280V 400V E
KBPC606 BR606 600V 420V 600V
KBPC608 BR608 800V 560V 800V D

KBPC610 BR610 1000V 700V 1000V


G

+ AC

Electrical Characteristics @ 25°C Unless Otherwise Specified A


Average Forward IF(AV) 6.0A TJ = 50°C AC -
Current
Peak Forward Surge IFSM 150A 8.3ms, half sine
Current
Maximum Forward A
Voltage Drop Per VF 1.10V IFM = 3.0A;
Element TJ = 25°C*
DIMENSIONS

Maximum DC INCHES MM
Reverse Current At IR 10µA TJ = 25°C DIM MIN MAX MIN MAX NOTE
A .578 .618 14.69 15.71 2PL
Rated DC Blocking 1 mA TJ = 100°C B .230 .270 5.84 6.86
Voltage C .750 --- 19.10 ---
D .405 .444 10.30 11.30 2PL
*Pulse test: Pulse width 300 µsec, Duty cycle 1% E .038 .042 0.97 1.07 4PL/TYP
G .145 --- 3.70 --- ∅

www.cnelectr.com
KBPC6005 thru KBPC610
Figure 1
Figure 2
Typical Forward Characteristics
Typical Reverse Characteristics

100 10

60 6

40 4

20 2

1
10
.6
6
.4
4

.2
2
TJ=25°C
25°C
µAmps .1
Amps 1
.06
.6
.04
.4

.02
.2
.01
.1
.006
.06
.00
.04 4
.002
.02
.001
.01 20 40 60 80 100 120 140
.2 .4 .6 .8 1.0 1.1 1.2
Volts
Volts
Instantaneous Forward Current - Amperesversus Instantaneous Reverse Leakage Current - MicroAmperesversus
Instantaneous Forward Voltage - Volts Percent Of Rated Peak Reverse Voltage - Volts

Figure 3 Figure 4
Forward Derating Curve Peak Forward Surge Current
6.0 300

250
5.0

200
4.0
150
3 .0 Amps
Amps 100

2.0
50

1.0 0
Single Phase, Half Wave 1 2 4 6 8 10 20 40 60 80 100
60Hz Resistive or Inductive Load 00
Cycles
0
0 25 50 75 100 125 150
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
Average Forward Rectified Current - Amperes versus
Case Temperature - °C

www.cnelectr.com