000
Re-apply the power after the parameter has been input
001
TH Alarm (A character with incorrect parity was input) Correct the tape
002
TV Alarm (The number of characters in a block is odd). This alarm will be generated only when the TV check is
effective
003
Data exceeding the maximum allowable number of digits was input
004
A numeral or the sign (-) was input without an address at the beginning of the block
005
The address was not followed by the appropriate data but was followed by another address of EOB code
006
Sign "-" input error (sign "-" was input after a address with which it can't be used. Or two "-" signs were used).
007
Decimal Point "." Input error (A decimal point was input after a address with which it can't be used. Or two
decimal points were input).
008
The switch position of the tape reader was not AUTO (without reel) or REEL ON/REEL OFF (with reels).
009
Unusable character was input. (E).
010
A unusable G code was commanded. (The alarm is generated also when a G code with which the control is not
equipped as an option is commanded).
011
Feedrate was not commanded at cutting feed or the feedrate was inadequate
015
The number of the commanded axes exceeded that of the allowable simultaneously controlled axis
017
The move commanded of the additional axis was commanded without equipping with an optional additional
axis.
018
An additional axis was commanded with the other axis simultaneously.
021
The axis not included in the selected plane (by using G17, G18, G19) was commanded in circular interpolation.
022
In circular interpolation, radius designation was performed in the NC which is not equipped with the radius
designation option.
023
In circular interpolation by radius designation, Zero was commanded for address R.
030
The tool offset number is too large for the D or H function.
031
In setting of offset amount by G10, The offset number following address P was excessive or it was not
specified.
032
In setting of offset amount by G10, the offset amount was excessive.
035
Skip Cutting (G31) was commanded in cutter compensation mode.
036
G45-G48 (Tool Offset) was commanded in cutter compensation mode.
037
The selected (by using G17, G18 or G19) changed in cutter compensation mode.
038
Over cutting will occur in cutter compensation because the arc start point or end point coincides with arc center
041
Overcutting will occur in cutter compensation.
044
One of G27-G30 was commanded in canned cycle mode. An ATC cycle (M06) was commanded in canned cycle
mode.
045
An ATC cycle (M06) was commanded for the NC which is not equipped with optional reference point return
feature.
046
Other than P2, P3 and P4 was specified in the 2nd, 3rd and 4th reference point return commands.
047
G27 to G30 was commanded for and axis which does not have a reference point.
058
In 4-digit S code binary 12-bit/analogue output A, A command was specified exceeding the maximum or
minimum number of spindle revolutions.
059
No program for selected work number is found (external work number select A function).
060
Commanded sequence number was not found in the sequence number search,
065
Scaling Magnification was specified as other than 1-99999.
066
Scaling was applied and as a result, movement value, coordinate value, circular arc radius, etc. exceed
maximum programmable dimension.
067
G51 (scaling ON) was specified in cutter compensation mode.
070
The Fanuc memory area is insufficient.
071
The address to be searched was not found.
072
The number of programs to be stored exceeds 95 or 191. (191 is a option(.
073
The program number has already been used.
074
The program number is other then 1-9999
075
The program number or sequence number was not found at the start block of the program
076
The address P was commanded in the block with includes a M98 command.
077
The subprogram was called in triple
078
The sequence number which was specified by address P in the block which includes a M98 or M99 was not
found
079
Memorized program and tape contents do not coincide
085
When storing data in memory by using ASR or RS232C interface, an over-run or framing error was generated
086
The signal level of RS232C interface was incorrect
087
When storing data in the memory by using the Fanuc RS232 interface, the time required to store the data is
insufficient.
090
The reference point return cannot be performed normally because the reference point return start point is to
close to the reference point or one revolution signal is not input owing to a fault in the pulse coder.
091
Reference point return cannot be executed normally, because of the feedrate is too low to synchronise the one
revolution signal of the pulse coder with the reference counter,
092
The axis designated by G27 did not return to reference point.
094
No P type can be specified for program restart (because after program interruption, coordinate system setting
or ORIGIN, etc. was executed)
095
No P type can be specified for program restart (because after program interruption, external work zero point
offset value changed)
096
No P type can be specified for program restart (because after program interruption, work zero point offset value
changed).
097
No P type can be specified for program restart (because after program interruption, no automatic operation has
been executed).
100
The switch to set parameters is on. Push the reset button after turning off the switch.
101
The power was turned off while rewriting the contents of memory in the part program storage & editing
operation. When this alarm is generated you must turn on the power while pushing the DELETE and RESET
buttons to clear the memory.
110
Absolute value of data of fixed point representation exceeds the upper bound (99999999).
111
Exponent of data of floating point representation exceeds the upper bound.
112
Divisor is 0
113
A function that cannot be used by user macro A is used
114
Format error except for
115
Value not defined as variable number is assigned
116
Left side of substituted sentence is a variable of prohibited substitution
118
Nesting of brackets exceeds the upper limit (5).
119
Argument of SQRT is negative , Or argument of BCD is negative
122
Nesting of macro exceeds the upper limit (4)
123
Macro control command is uded in tape mode
124
DO END is not 1:1 corresponding
125
Format error of (formula)
126
Not 1 ≤ n ≤ 3 in DO n
127
NC command and macro command are mixed
128
Not 0 ≤ n ≤ 9999 in GO TO n
129
Unallowable address is used in .
130
In external data input, greater-address data contains an error
131
In external alarm message, five or more alarms have occurred
132
In external alarm message, clear, no corresponding alarm number exsists
133
In external alarm message and in external operator message, smaller- address data contains an error
170
Programs of numbers 8000 – 8999 and 9000 – 9899 are being edited, But this alarm occurs only when
parameter setting inhibits these programs to be edited.
Error on Stroke Limit Switch
210
The movable part of machine touched the X Axis plus stroke limit switch
211
The movable part of machine touched the X Axis minus stroke limit switch
212
While the X Axis was moving in the plus direction, It entered into the forbidden area of the stored stroke limit 1
213
While the X Axis was moving in the minus direction, It entered into the forbidden area of the stored stroke limit
1
214
While the X Axis was moving in the plus direction, It entered into the forbidden area of the stored stroke limit 2
215
While the X Axis was moving in the minus direction, It entered into the forbidden area of the stored stroke limit
2
220
The movable part of the machine touched the Y axis plus stroke limit switch
221
The movable part of the machine touched the Y axis minus stroke limit switch.
222
While the Y axis was moving in the plus direction, it entered into the forbidden area of the stored stroke limit 1
223
While the Y axis was moving in the minus direction, it entered into the forbidden area of the stored stroke limit
1
224
While the Y axis was moving in the plus direction, it entered into the forbidden area of the stored stroke limit 2
225
While the Y axis was moving in the minus direction, it entered into the forbidden area of the stored stroke limit
2
230
The movable part of the machine touched the Z axis plus stroke limit switch
231
The movable part of the machine touched the Z axis minus stroke limit switch
232
While the Z axis was moving in the plus direction, it entered into the forbidden area of the stored stroke limit 1
233
While the Z axis was moving in the minus direction, it entered into the forbidden area of the stored stroke limit
1
234
While the Z axis was moving in the plus direction, it entered into the forbidden area of the stored stroke limit 2
235
While the Z axis was moving in the minus direction, it entered into the forbidden area of the stored stroke limit
2
240
The movable part of the machine touched the 4th axis plus stroke limit switch
241
The movable part of the machine touched the 4th axis minus stroke limit switch
Error on servo system
400
The control received the X, Y or Z axis overload signal
401
The READY signal (VRDY) of the X, Y or Z axis velocity control has turned off
402
The control received the 4TH axis overload signal
403
The READY signal (VARY) of the 4TH axis velocity control has turned off
404
The READY signal (VARY) of the X, Y or Z axis velocity control does not turn off even though the READY signal
(PRDY) of the position control has turned off
The READY signal (VARY) of velocity control already on even though the READY signal (PRDY) of the position
control is off yet at power on condition
405
In reference point return, reference point return is not performed in correctly by abnormality of NC control
section or servo system. Perform manual reference point return again
410
The content of error register of the X axis is larger than the value allowed while the machine is stopped
411
The content of error register of the Y axis is larger than the value allowed while the machine is moving
412
Drift in X axis is excessive. (Exceeds 500VELO)
413
The content of the error register of the X axis exceeded =32767. Or the velocity command value of the DA
converter is out of the range of +8191~ - 8192. Incorrect settings will cause this alarm
414
The resolver/inductosyn position detecting system of X axis is trouble
415
A feed rate exceeding 511875 detection units/sec was commanded in the X axis
An incorrect setting of CMR causes this error
416
X axis pulse coder position feedback is abnormal. (Disconnection alarm)
420
The content of the error register of the Y axis is larger than the value allowed while the machine is stopped
421
The content of the error register of the Y axis is larger than the value allowed while the machine is moving
422
Drift in Y axis is excessive. (Exceeds 500VELO)
423
The content of the error register of the Y axis exceeded =32767. Or the velocity command value of the DA
converter is out of the range of +8191~ - 8192. Incorrect settings will cause this alarm
424
The DSCG position detecting system of the Y axis is trouble
425
A feed rate exceeding 511875 detection units/sec was commanded in the Y axis
An incorrect setting of CMR causes this error
426
Y axis Fanuc pulse coder position feedback is abnormal. (Disconnection alarm)
430
The content of the error register of the Z axis is larger than the value allowed while the machine is stopped
431
The content of the error register of the Z axis is larger than the value allowed while the machine is moving
432
Drift in Z axis is excessive. (Exceeds 500VELO)
433
The content of the error register of the Z axis exceeded =32767. Or the velocity command value of the DA
converter is out of the range of +8191~ - 8192. Incorrect settings will cause this alarm
434
The resolver/inductosyn position detecting system of Z axis is trouble
435
A feed rate exceeding 511875 detection units/sec was commanded in the Z axis
An incorrect setting of CMR causes this error
436
Z axis pulse coder position feedback is abnormal. (Disconnection alarm)
440
The content of the error register of the 4TH axis is larger than the value allowed while the machine is stopped
441
The content of the error register of the 4TH axis is larger than the value allowed while the machine is moving
442
Drift in 4TH axis is excessive. (Exceeds 500VELO)
443
The content of the error register of the 4THaxis exceeded =32767. Or the velocity command value of the DA
converter is out of the range of +8191~ - 8192. Incorrect settings will cause this alarm
444
The resolver/inductosyn position detecting system of the 4TH axis is trouble
425
A feed rate exceeding 511875 detection units/sec was commanded in the 4TH axis
An incorrect setting of CMR causes this error
426
Additional axis pulse coder position feedback is abnormal. (Disconnection alarm)
Connection alarm between each PCB
600
Data transferring error took place in the connection unit or in PC-model C
601
Slave relay was turned off. (Connections among unit, MDI/DPL (MDI/CRT) and master PCB are trouble. Another
case change connection unit)
602
PC program has not yet been loaded
603
The correspondence between NC and PC is incorrect or interrupted. Change power sequence control PCB or
master PCB
604
No hold is effective to PC-model B side MPU
605
A system error has occurred in PC-model B side MPU
606
RAM/ROM parity has occurred in PC-model B side MPU
607
Data transferring error took place in Fanuc MDI & CRT
Overheat alarm
700
Overheat of the master PCB
701
Overheat of the PCB for 4TH axis
702
Overheat of DC motor for X, Y, Z axis
703
Overheat of DC motor for 4TH axis
Errors on memory
900
Fault in bubble device. (Fault of input signal for bubble device)
901
Fault in bubble device. (The initial point in the bubble was not detected immediately after power on)
902
Fault in bubble device. (Page size error, undefined command)
903
Fault in bubble device. (Transfer missing, page size over)
904
Fault in Fanuc bubble device. (Parity error)
905
Fault in bubble device. (No marker)
906
Fault in bubble device. (Many defect loops)
910
RAM parity error (low byte)
911
RAM parity error (high byte)
920
System error (watch dog timer alarm)
930
CPU error (0, 3, 4 type interrupt generation)
997
ROM parity error (PC ROM)
998
ROM parity error (Basic ROM)
999
ROM pair error (No correspondence between high and low)