Sunteți pe pagina 1din 6

Energy Content in Waste 5662 kJ/kg

Energy Content in LPG 48000 kJ/kg


LPG rate
Waste feeding rate
PRIMARY CHAMBER

WASTE FEEDING RATE 30 kg/hr


Energy from Waste 169860 kg/hr
CO in exhaust 11.49 kg/hr
LPG burning Rate 0.732 kg/hr
Energy From LPG 35136 kJ/hr
CO2 in Exhaust 2.2 kg/hr
H2O in Exhaust 24.5 kg/hr
Theoritical air required 111 kg/hr
Actual air maintained 123 kg/hr
Oxygen in exhaust 7.8 kg/hr
N2 in exhaust 94 kg/hr
Total exhaust Gas flow rate 140.0 kg/hr
Primary chamber temperature 800 C
Ash generated 5.4 kg/hr
Energy Loss by ash 6480 kJ/hr
Energy Loss in exhaust gas 178016 kJ/hr
Energy in 184496.4 kJ/hr
Energy out 184496 kJ/hr
Delta Energy 0 kJ/hr
SECONDARY CHAMBER

LPG burning Rate 5


Chamber temperature 1400
x1 Energy in Chamber 1 exhaust 223149
G1 CO2 in exhaust 36
H2O in exhaust 33
x2 Theoritical Air required 75.6
x3 Actual air required 90.7
N2 in exhaust Gas 163.6
A1 O2 in exhaust gas 3.5
x4 Exhaust Gas Flow rate 235.9
x5 Energy in Exhaust Gas 426662.80
E1 Energy in 426663
Energy Out 426662.80
Delta energy 0

Power in Exhaust Gas 107.8


Recoverable energy 107.8
Heat Exchanger efficiency 40%
Enegy for steam generation 43.1
Steam Production Rate 0.016
57.0
kg/hr
C
kJ/hr
kg/hr x6
kg/hr x7
kg/hr
kg/hr A2
kg/hr
kg/hr
kg/hr E2
kJ/hr
kJ/hr
kJ/hr
kJ/hr

kW
kW

kW
kg/s
kg/hr
Combustion Intensity 1405 Btu/cu.ft.hr #4 waste
5425 # 3waste
Total Heat Input 204996 kJ/hr
Required Chamber Volume 4.13 cu.m # 4 waste
1.07 cu.m #3 waste
LPG burner capacity 9.8 kW
Combustion air flow rate (Waste+LPG) 72 cfm
Total gas flow rate within the chamber 236 kg/hr
139 cfm
0.066 cu.m/s
Recommended residence time of gas within the chamber 1s
Length of the burning chamber 0.8 m
Required diameter of the burning chamber 0.32 m
12.7 inch
LPG Burner Power requirement 70 kW
Flue Gas Flow rate 235.9 kg/hr
Flue Gas Temperature 1400 Celsius
Recommended Flue gas temperature 250 Celsius
Energy Released From Flue Gas 358147.6 kJ/hr
99.48545 kJ/s
Overall Heat Transfer Coefficient 40
Cold Fluid outlet temperature 200
LMTD 577.6772
Required HE surface Area 4.305409 sq.m
Length of the circular chamber 0.5 m
No.of Pipe Turns 80
Diameter of circular pipe 1.35 inch

S-ar putea să vă placă și