InteliLiteNT

Controller for single gen-set


applications

SW version 2.3.0
1 General information 2
2 Changes in the version 2.3.0 3
3 Related information 8
4 Notes 10

Copyright © 2016 ComAp a.s.


Written by Petr Charouzek
Prague, Czech Republic
ComAp a.s., U Uranie 14a/1612,
170 00 Prague 7, Czech Republic
Tel: +420 246 012 111
E-mail: info@comap.cz, www.comap.cz New Features List
1 General information
1.1 Version information
This firmware version consist many new features, like configurable Choke output and adjustable D+ for small
Gen-sets, full Modbus communication and added machine state in SNMP. Also bugs were repaired and
Ukrainian and Chinese languages are more supported.

1.2 Clarification of notation


Note: This type of paragraph calls readers attention to a notice or related theme.

IMPORTANT: This type of paragraph highlights a procedure, adjustment etc., which can cause a
damage or improper function of the equipment if not performed correctly and may not be clear at
first sight.

Example: This type of paragraph contains information that is used to illustrate how a specific function
works.

New Features List IL-NT 2.3.0 2


2 Changes in the version 2.3.0
2.1 New features
Choke LBO for MRS3, MRS4, AMF8, AMF9
This is a feature for small petrol gen-sets, where electronic choke control is needed. CHOKE LBO can be
activated during Prestart and Starting state and it is always deactivated at the latest at the end of
Cranking state. Choke function can be set by these setpoints:
Choke Time
Time lenght when CHOKE LBO is activated during Prestart and Cranking
Range: 0 - (MaxCrankTime + ChokeLead)
Defaul Value: 0
Choke Lead
Time lenght when CHOKE LBO is activated during Prestart, it can be used when choke is opening
slowly.
Range: 0 - 7 s (maximum value of Choke Lead is limited by actual Prestart Time, Choke Lead ≤
Prestart Time)
Default Value: 0

This binary output and input was added:


LBO CHOKE
Binary output connected to gen-set Choke
Can be configured as standard binary output
LBI CHOKE INHIBIT
Binary input used to deactivate LBO Choke
When LBI Choke Inhibit is activated, LBO Choke is deactivated immediately
Can be configured as standard binary input

New Features List IL-NT 2.3.0 3


Image 2.1 Start attempt with Choke

Image 2.2 Start attempt with Choke

Adjustable D+ threshold for MRS3, MRS4, AMF8, AMF9


This is a feature for small petrol gen-sets, where D+ voltage does not reach 80% of controller supply
voltage. Normaly it caused Warning ChargeAlt Fail. Now the threshold and delay can be adjusted by
these setpoints:
D+ WrnThreshold
Voltage threshold in percent to evaluate Warning ChargeAlt Fail
Range: 0 - 100 %, where 100 % is supply voltage
Default Value: 80 %
D+ Delay
Time delay when D+ voltage is evaluated
Default Value: 1 s

New Features List IL-NT 2.3.0 4


During starting state: D+ voltage is evaluated as one of condition to deactivate a STARTER LBO -
when D+ voltage is reached, STARTER LBO is deactivated after D+ Delay is elapsed. Next condition
which deactivates STARTER LBO is elapsing of Cranking time or starting RPM are reached.
During Running state: D+ voltage is evaluated as condition to activate Warning ChargeAlt Fail based
on setpoints D+ WrnThreshold and D+ Delay

Modbus commnunication for MRS3, MRS4, AMF8, AMF9


Modbus is fully avalaible for communication modules via setpoint group Comm Settings. It is adjusted by
these setpoints:
Controller Adress
Controller identification number. It is possible to set controller address different from the default
value (1) so that more IL controllers can be interconnected (via RS485) and accessed e.g. from
Modbus terminal.
Range: 1 - 32
COM1 Mode
Communication protocol switch for the COM1 channel.
Values:
DIRECT: LiteEdit communication protocol via direct cable.
MODEM: LiteEdit communication protocol via modem.
MODBUS: Modbus protocol. See detailed description in InteliCommunication guide.
ECU LINK: Protocol for communication with Cummins engines via Modbus.
COM2 Mode
Values:
DIRECT: LiteEdit communication protocol via direct cable.
MODBUS: Modbus protocol. See detailed description in InteliCommunication guide.
ECU LINK: Protocol for communication with Cummins engines via Modbus.
ModemIniString
If your modem needs some additional initialization AT commands (i.e. because of national
telephony network differences), it can be entered here. Otherwise leave this setpoint blank.
ModbusComSpeed
If the Modbus mode is selected on COM1 or COM2 channels, the Modbus communication speed
in bps can be adjusted here.
Values: 9600,19200, 38400, 57600

New Features List IL-NT 2.3.0 5


Machine state added in SNMP
Machine state is available in MIB table. It is Read only value. SNMP is suppoted by IB-Lite module.
Machine state values are follows:
20 Init 29 Shutdown 38 MainsRet 47 AfterCool
21 Not ready 30 Ready 39 Brks Off 48 GCB Open
22 Prestart 31 Cooling 40 No Timer 49 StopValve
23 Cranking 32 EmergMan 41 MCB Close 50 Start Del
24 Pause 33 ManIdle 42 ReturnDel 51 (1Ph)
25 Starting 34 MainsOper 43 Trans Del 52 (3PD)
26 Running 35 MainsFlt 44 Idle Run 53 (3PY)
27 Loaded 36 MainsFlt 45 MinStabTO 54 MRS Mode
28 Stop 37 IslOper 46 MaxStabTO
To generate MIB table go to LiteEdit 4.6 or higher and use “Controller” -> “Generate Cfg image” ->
“Generate SNMP MIB table”
Refer to IB-Lite New features list for more information about SNMP support.

Frequency selection support for AMF9 a MRS4


ECU Frequency selection support added when ECU is configured (for Volvo, Scania and Cummins
engines). These setpoints are visible when ECU is configured:
ECU FrequencySelect
Values: DEFAULT, PRIMARY, SECONDARY
Default Value: DEFAULT
ECU SpeedAdj
Enables to adjust engine speed in ECU via CAN bus. Nominal speed corresponds to 50%. The
minimum value 0% is equal to 90% of nominal speed. Maximum value 100% is equal to 110% of
nominal speed.
Range: 0 - 100 %
Default Value: 50 %

New Features List IL-NT 2.3.0 6


2.2 Repairs
Missing symbols of Ukrainan language
Symbols added in Cyrilic code page
Missing values of kWh and kVArh when Chinesse language selected
Added values to:
AMF25 - Genset kWh, Genset kVARrh, Mains kWh, Mains kVArh
AMF8, 9, 20 - Genset kWh, Genset kVARrh - added new screen
MRS15, 16 - Genset kWh, Genset kVARrh
MRS3, 4, 10, 11 - Genset kWh, Genset kVARrh - added new screen
When LBO1 is configured as Not Used, it is permanently acivated
Repaired, when LBO1 isconfigured as Not Used, it is deactivated
Wrong Fls Oil Pressure evaluation
Engine is able to start even Oil pressure sensor is disconnected
When Oil Pressure analog input Direction was set to UnderLimit+Fls, sensor was disconnected and
thenFault Reset was pressed. It was possible to start engine manualy. Gen-set Red and Green LED
lights. It could cause Gen-set running with zero Oil Pressure
Now, after Oil Pressure sensor is disconnected, SdOilPressure alarm is evaluated and manual Gen-
set start is not allowed until Oil Pressure sensor is properly connected again. Gen-set Red LED
lights.
Undervoltage protection evaluation - MRS19
When engine was started with Generator current higher then zero, voltage autodetection was skipped
and alarm Sd Gen L1 and Sd Gen L3 appears and it terminates engine running. Alarm Sd Gen L1 and Sd
Gen L3 was evaluated incorrectly.
Now, voltage is autodetected at each starting sequence.

New Features List IL-NT 2.3.0 7


3 Related information
3.1 Available files
Firmware (*.mhx)
For: IL-NT AMF(8,9,20,25), MRS(3,4,10,11,15,16,19)
IL-NT-AMF(8,9,20,25), MRS(3,4,10,11,15,16,19)-2.3.0.mhx

Table 3.1 Available firmware

Archives (*.ail)
For: IL-NT AMF(8,9,20,25), MRS(3,4,10,11,15,16,19)
IL-NT-AMF(8,9,20,25), MRS(3,4,10,11,15,16,19)-2.3.0.ail

Table 3.2 Available archives

3.2 Overview of all available hardware


IL-NT
Binary Inputs 4 - 7 (based on IL-NT type)
Binary Outputs 4 - 7 (based on IL-NT type)
Analog Inputs 3
Analog Outputs 0
Communications RS232, RS485, USB, Ethernet, GPRS

Table 3.3 Available hardware

New Features List IL-NT 2.3.0 8


3.3 Available related documentation
Documents Description
Reference guide
IL-NT-MRS3,4-AMF8,9-2.2 Reference Guide.pdf
Link to ComAp download page
Rererence guide
IL-NT-MRS-2.2 Reference Guide
Link to ComAp download page
Rererence guide
IL-NT-AMF-2.2 Reference Guide
Link to ComAp download page
Global guide
LiteEdit 5.0.0 Global Guide
Link to ComAp download page
New Features List
LiteEdit 5.4.0 New Features
Link to ComAp download page

Table 3.4 Available documentation

New Features List IL-NT 2.3.0 9


4 Notes
4.1 Document history
Revision number Related sw. version Date Author
0 2.3.0 8.9.2016 Petr Charouzek

New Features List IL-NT 2.3.0 10