Sunteți pe pagina 1din 66

OptiX RTN 900 Data Configuration

(Hybrid Domain)
ISSUE 1.10
OptiX RTN 900 Data Configuration(Hybrid Domain) Contents

Contents
Course Instruction ........................................................................................................................1
About this course .........................................................................................................................1
Course objectives ........................................................................................................................1
Relevant Materials .......................................................................................................................1
Chapter 1 Radio link configuration ............................................................................................... 2
1.1 Starting Web-LCT ..................................................................................................................2
1.2 Creating NE by Using the Manual Method ............................................................................3
1.3 Creating NE by Using the Search Method .............................................................................5
1.4 Configuring the logical boards ...............................................................................................6
1.5 Modifying the NE ID/Name ....................................................................................................7
1.6 Configuring Orderwire ............................................................................................................8
1.7 Synchronizing the NE Time ...................................................................................................9
1.8 Configuring the Performance Monitoring Status of NE....................................................... 10
1.9 Creating XPIC Protection Group ......................................................................................... 10
1.10 Configuring N+1 Protection .............................................................................................. 13
1.11 Creating IF 1+1 Protection Group ..................................................................................... 14
1.12 Configuring the IF/ODU Information of Microwave Links ................................................. 17
Chapter 2 TDM Services Configuration .....................................................................................20
2.1 Configuring Cross-Connections .......................................................................................... 20
2.2 Configuring Cross-Connections for SNCP Services .......................................................... 21
Chapter 3 Configuring EoSDH/PDH-Based Ethernet Services .................................................22
3.1 Configuring EPL Services ................................................................................................... 22
3.2 Configuring QinQ-Base EVPL Services ............................................................................. 25
3.3 Configure EPLAN Services................................................................................................. 29
Chapter 4 Configuring Native Ethernet Services .......................................................................35
4.1 Configuring the Parameters of Ethernet Ports .................................................................... 36
4.2 Configuring the Parameters of IF_ETH Ports ..................................................................... 39
4.3 Configuring LAGs ............................................................................................................... 41
4.4 Configuring QinQ Links ....................................................................................................... 43
4.5 Configuring E-Line Services ............................................................................................... 44
4.6 Configuring ERPS ............................................................................................................... 46
4.7 Configuring 802.1d Bridge-Based E-LAN Services ............................................................ 48
4.8 Configuring 802.1q Bridge-Based E-LAN Services ............................................................ 51
4.9 Configuring 802.1ad Bridge-Based E-LAN Services .......................................................... 52

Confidential Information of Huawei. No Spreading without Permission i


OptiX RTN Data Configuration (Hybrid Domain) Contents

Task1 Basic Configuration .........................................................................................................53


Task2 TDM Services Configuration ........................................................................................... 54
Task3 EoPDH-Based EPL Services Configuration ....................................................................55
Task4 EoPDH-Based EPLAN Services Based-on Configuration ..............................................56
Task5 Configuring Point-to-Point Transparently Transmitted E-Line Services ......................... 57
Task6 Configuring VLAN-Based E-Line Services ......................................................................58
Task7 Configuring QinQ-Based E-Line Services .......................................................................59
Task8 802.1d Bridge-Based E-LAN Services ............................................................................60
Task9 802.1q Bridge-Based E-LAN Services ............................................................................61

Confidential Information of Huawei. No Spreading without Permission ii


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

Course Instruction

About this course


This course Guide is applicable to:RTN 900V1R3/V1R5&U2000Weblct
V100R006.
This course is applicable to OptiX RTN 900 products.
This course guides the trainees to finish the service configuration of OptiX
RTN 900 products.
This course helps the trainees to accumulate experience of service
configuration.

Course objectives
Upon completion of this course, you will be able to:
 Configure radio links of the OptiX RTN 900 via U2000 WEB-LCT
 Configure Hybrid services of the OptiX RTN 900 via U2000 WEB-LCT

Relevant Materials
Configuration guide of OptiX RTN 900 product manual

Confidential Information of Huawei. No Spreading without Permission 1


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

Chapter 1 Radio link configuration

Steps Description Remarks

1 Starting Web-LCT

2 Creating NE by Using the Manual Method

3 Creating NE by Using the Search Method

4 Configuring the logical boards

5 Modifying the NE ID/Name

6 Orderwire Configuration

7 NE Time Synchronization

8 Enabling NE Performance Monitor

9 Creating XPIC Protection Group

10 Configuring N+1 Protection

11 Creating IF 1+1 Protection Group

12 Configuring the IF/ODU Information of Microwave Links

1.1 Starting Web-LCT


Step Action

1 a) Start the Computer


b) Check the IP and Submask of Computer, the computer and the device must be
in the same network segment. such as 129.9.xx.xx.
2 Use the Ethernet cable connects to the computer with the product directly.

Double-click on the desktop, starting the Web-LCT.

Confidential Information of Huawei. No Spreading without Permission 2


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

 Click “Login”
 User name : admin
 Password: Changeme_123
 Notes: different version has different password

1.2 Creating NE by Using the Manual Method


Step Action

Confidential Information of Huawei. No Spreading without Permission 3


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

Step Action

 NE ID: The ID refers to the basic ID. If the extended ID is not used, the basic ID of
an NE must be unique on the networks that are managed by the same NMS.
 The NE ID consisting of the basic ID and extended ID identifies an NE on the
NMS.
 Extended ID(1 to 254): If the number of existing NEs does not exceed the range
represented by the basic ID, do not change the extended ID.
 Gateway Type: This parameter is set to Gateway if the new NE is a gateway NE.
It is set to Non-Gateway also if the new NE is a non-gateway NE.
 This parameter is set according to the DCN planning if the new NE can function
as a gateway NE or a non-gateway NE.
 IP Address: The IP address of gateway NE.
 Port: Communication port.
 User Name: lct
 Password: password

Confidential Information of Huawei. No Spreading without Permission 4


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

1.3 Creating NE by Using the Search Method

Step Action

 Domain: When the IP address of the GNE is known, it is recommended that you set
the IP address range of the GNE as the search domain. In the case of initial
configuration, it is recommended that you set the 129.9.255.255 network segment as
the search domain.
 Search for NE: It is recommended that you select Search for NE, add device after
search NE User. By default, NE User name is lct and Password is password.

Confidential Information of Huawei. No Spreading without Permission 5


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

1.4 Configuring the logical boards

Step Action

 Based on the slot layout, the NE automatically configures the logical boards that are
required but still not be configured for certain physical boards.
 The aqua slots mean that the physical boards have already there but still not be
configured for logical boards.

Confidential Information of Huawei. No Spreading without Permission 6


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

1.5 Modifying the NE ID/Name

Step Action

 Modify the NE ID according to the engineering planning to guarantee that each


NE ID is unique. Modifying the NE ID does not interrupt services.

Confidential Information of Huawei. No Spreading without Permission 7


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

1.6 Configuring Orderwire

Step Action

Notes: Choose the board from the Available Orderwire Port, and configure the
Phone number.

Confidential Information of Huawei. No Spreading without Permission 8


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

1.7 Synchronizing the NE Time

Step Action

 Notes: When you need to synchronize the NE time with the time on the NTP
server, set the time synchronization mode to Standard NTP.

Confidential Information of Huawei. No Spreading without Permission 9


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

1.8 Configuring the Performance Monitoring Status of NE

Step Action

1.9 Creating XPIC Protection Group

Step Action

 If the IF board is IFX2 or ISX2 or ISV3, the XPIC function can be supported.

Confidential Information of Huawei. No Spreading without Permission 10


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

Step Action

 Set IF Channel Bandwidth to 7M or 14M or 28M or 40M or 56M according to the


network planning file. Set IF Channel Bandwidth to 56M if high-power ODUs are used.
 Set the polarization directions of microwave links. It is recommended that you install
the two IFX2/ISX2/ISV3 boards that form an XPIC workgroup in the slots that are in the
same row or column of the chassis. Set the IF port on the IFX2/ISX2/ISV3 board that is
housed in the slot with a smaller slot number to Polarization direction-V and the IF
port on the other IFX2/ISX2/ISV3 board to Polarization direction-H.
 Set Link ID-V (link ID for the vertical polarization direction) and Link ID-H according to
the network planning file. These two parameters must be set to different values, but
Link ID-V must be set to the same value at the two ends of a link and Link ID-H must
be set to the same value at the two ends of a link.
 Set Transmit Power (dBm). Transmit Power (dBm) indicates the maximum transmit
power of an ODU, and therefore its value must not exceed the rated power range
supported by the ODU. This parameter specifies the upper threshold of the transmit
power range of an ODU. After an ATPC adjustment, the transmit power cannot
exceed the value of this parameter.
 Set Transmit Power (dBm) and Transmission Frequency (MHz) according to the
network planning file.
 Set ATPC parameters according to the network planning file. Note that before the
antenna alignment,
Confidential ATPC Enabled
Information must
of Huawei. No be disabled.
Spreading without Permission 11
OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

Step Action

 Set AM Enable Status according to the network planning file. Before antenna
alignment, ensure that AM Enable Status is disabled.
 If you set AM Enable Status to Enabled, set Modulation Mode of the Guaranteed AM
Capacity and Modulation Mode of the Full AM Capacity according to the network
planning file.
 Notes:E1 Capacity specifies the number of E1 services that can be transmitted in
Hybrid microwave frames. Set this parameter according to the network planning file.
The number of E1 services at both ends of a microwave link hop must be the same.
Otherwise, the services are unavailable.

Confidential Information of Huawei. No Spreading without Permission 12


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

1.10 Configuring N+1 Protection

Step Action

 When multiple STM-1 or Hybrid microwave services are transmitted in the


point-to-point mode, you can adopt the N+1 protection.
2

 WTR time(s): This parameter specifies the wait-to-restore (WTR) time. When the time
after the former working channel is restored to normal reaches the set WTR time, a
revertive switching occurs. It is recommended that you use the default value.
 SD enabled: This parameter specifies whether the SD switching function of N+1
protection is enabled. When this parameter is set to Enabled, the SD condition is
considered as a trigger condition of protection switching. It is recommended that you
set this parameter to Enabled.

Confidential Information of Huawei. No Spreading without Permission 13


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

1.11 Creating IF 1+1 Protection Group

Step Action

Confidential Information of Huawei. No Spreading without Permission 14


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

Step Action

 Working Mode: This parameter specifies the working mode of the IF 1+1
protection. Select HSB, SD, or FD from the Working Mode drop-down list. The FD
mode and SD mode are compatible with the HSB switching function.
 Revertive Mode: When this parameter is set to Revertive Mode, the NE that is in
the switching state releases the switching and enables the former working channel
to return to the normal state some time after the former working channel is restored
to normal. When this parameter is set to Non-Revertive, the NE that is in the
switching state keeps the current state unchanged unless another switching occurs
even though the former working channel is restored to normal.
 WTR Time(s): You can set WTR Time(s) only when Revertive Mode is set to
Revertive Mode. The range is 300 to 720. It is recommended that use the default
value.
 Enable Reverse Switching: When both the main IF board and the standby IF board
at the sink end report service alarms, they send the alarms to the source end by
using the MWRDI overhead in the microwave frame. When this parameter at the
source end is set to Enabled and the reverse switching conditions are met, the IF 1+1
protection switching occurs at the source end. This parameter is valid only when
Working Mode is set to HSB or SD.
 Alarm Report Mode: When Alarm Report Mode is set to Only board alarms, only IF
board alarms are reported. When Alarm Report Mode is set to Only protection group
alarms, protection group alarms are reported if a protection group fails or degrades.
Service alarms on IF boards and radio links are suppressed. When Alarm Report
Mode is set to Protection group and board alarms, IF board alarms and protection
group alarms are reported.
 NOTE: Each of the parameters Working Mode, Revertive Mode, WTR Time(s), and
Enable Reverse Switching must be set to the same value at both ends of a radio
hop.
Confidential Information of Huawei. No Spreading without Permission 15
OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

Confidential Information of Huawei. No Spreading without Permission 16


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

1.12 Configuring the IF/ODU Information of Microwave Links

Step Action

Confidential Information of Huawei. No Spreading without Permission 17


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

Confidential Information of Huawei. No Spreading without Permission 18


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

2  Link ID: This parameter indicates or specifies the ID of a radio link. As the identifier
of a radio link, this parameter is used to prevent incorrect connections of radio links
between sites. If the value of Received Radio Link ID does not match the preset
value of Link ID at the local end, the local end inserts the AIS signal to the
downstream direction of the service. At the same time, the local end reports
MW_LIM alarm to the NMS, indicating that the link IDs do not match. Each radio
link of an NE should have a unique link ID, and the link IDs at both ends of a radio
link should be the same.
 Received Link ID: When the radio link becomes faulty, this parameter is displayed
as an invalid value.
 IF Service Type: If the Integrated IP radio transmits Native E1 services, set this
parameter to Hybrid(Native E1+ETH); If the Integrated IP radio transmits Native
STM-1 services, set this parameter to Hybrid(Native STM-1+ETH); If the SDH radio
transmits SDH services, set this parameter to SDH.
 IF Channel Bandwidth: This parameter is not applicable to the IF1 board; The IFU2
board does not support the value 40M; The IFX2 board does not support the values
7M, 14M, and 40M; The ISX2 board does not support the values 7M and 14M.The
ISV3 board support 7M,14M,28M,56M.
 AM: The ISX2/ISU2/ISV3 does not support the AM function when IF Service
Type is SDH.
 Modulation Mode: This parameter specifies the modulation scheme that the radio
link uses for signal transmission. It is valid only when AM Enable Status is set to
Disabled.
 STM-1 Capacity: If IF Service Type is Hybrid(Native STM-1+ETH), this parameter
can be set to 0 or 1. If IF Service Type is SDH, this parameter can be set to 1.
 Power to Be Received(dBm): This parameter is used to set the expected receive
power of the ODU and is mainly used in the antenna alignment stage. After this
parameter is set, the NE automatically enables the antenna misalignment
indicating function. When the antenna non-alignment indication function is
enabled, if the actual receive power of the ODU is 3 dB lower than the power
expected to be received, the ODU indicator on the IF board connected to the ODU
blinks yellow (300 ms on, 300 ms off), indicating that the antenna is not aligned.
 After the antenna alignment, after the state that the antenna is aligned lasts for 30
minutes, the NE automatically disables the antenna misalignment indicating
function.

Confidential Information of Huawei. No Spreading without Permission 19


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

Chapter 2 TDM Services Configuration

Steps Description Remarks

1 Configuring Cross-Connections

2 Configuring Cross-Connections for SNCP Services

2.1 Configuring Cross-Connections


Step Action

 E1 Priority: This parameter is available only if the E1 priority function is enabled


for the ports configured in the cross-connections. If E1 Priority is set to High,
transmission of the E1 service is ensured in any modulation scheme. If E1 Priority is
set to Low, transmission of the E1 service is ensured only in full-capacity
modulation scheme. If the service priority is not specified during service creation,
E1 Priority is None. In this case, the E1 priority of a service needs to be changed
after the service is created.
 NOTES: When 1+1 protection or 1+1 linear MSP is configured for a TDM service,
you need to configure the TDM service only on the working channel. When N+1
protection is configured for TDM services, you need to configure the extra service
on the protection channel if the extra service needs to be transmitted on the
protection channel.

Confidential Information of Huawei. No Spreading without Permission 20


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

2.2 Configuring Cross-Connections for SNCP Services

Step Action

 Revertive Mode: This parameter determines whether to switch the service from
the protection channel to the original working channel after the fault is rectified. If
this parameter is set to Revertive, the service is switched from the protection
channel to the original working channel. If this parameter is set to Non-Revertive,
the service is not switched from the protection channel to the original working
channel. It is recommended that you set this parameter to Revertive.
 Hold-off Time (100ms): When a line is faulty, SNCP switching can be performed on
the NE after a delay of time to prevent the situation where the NE performs SNCP
switching and other protection switching at the same time. If only the SNCP
scheme is available, it is recommended that you set the hold-off time to 0.

Confidential Information of Huawei. No Spreading without Permission 21


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

Chapter 3 Configuring EoSDH/PDH-Based


Ethernet Services

Steps Description Remarks

1 Configuring EPL Services

2 Configuring QinQ-Based EVPL Services

3 Configuring EPLAN Services

3.1 Configuring EPL Services

Step Action

Confidential Information of Huawei. No Spreading without Permission 22


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

2  Enable the Ethernet Port that need configure Ethernet service, and displays
or specifies the name of the external port.
 Different types of Ethernet ports support different Working Modes, if the
opposite port works in auto-negotiation mode, set this parameter to
Auto-Negotiation. (Generally, Working Mode of the external equipment is set
to Auto-Negotiation.) For Ethernet ports within a network, set Working Mode
to Auto-Negotiation.
 Maximum Frame Length: Set this parameter to a value greater than the
maximum length of all the data frames to be transmitted. When jumbo frames
are transmitted, set Max Frame Length(byte) according to the actual length
of the jumbo frames. Otherwise, it is recommended that Max Frame Length
(byte) takes its default value.

 Notes: Set Tag Attributes to Tag Aware if the port allows the access of only the
tagged frames, set Tag Attributes to Access if the port allows the access of
only the untagged frames, after the frames come in the port, the port gave it
the default VLAN ID. If set Tag Attributes to Hybrid then the port allows the
access of the tagged frames and untagged frames.

Confidential Information of Huawei. No Spreading without Permission 23


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

 Service Direction: Bidirectional or Unidirectional, in normal cases, it is


recommended that you set this parameter to Bidirectional.
 Source Port: When you create bidirectional Ethernet services from a PORT to
a VCTRUNK, it is recommended that you set the PORT to the source port.
 Source VLAN(e.g. 1,3-6) and Sink VLAN: if this parameter is set to null, all the
services at the source port are used as the service source, then this port or
VCTRUNK cannot sharing by VLAN ID. If this parameter is not set to null, only
the service that carries a specified VLAN ID at the source port can be used as
the service source, then the port or VCTRUNK can sharing by different VLAN
ID. And the number of VLANs must be the same as the value of Sink VLAN(e.g.
1,3-6).
 Sink Port: when you create bidirectional Ethernet services from a PORT to a
VCTRUNK, it is recommended that you set the VCTRUNK to the sink port.

Confidential Information of Huawei. No Spreading without Permission 24


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

3.2 Configuring QinQ-Base EVPL Services


Step Action

Confidential Information of Huawei. No Spreading without Permission 25


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

2  Enable the Ethernet Port that need configure Ethernet service, and displays
or specifies the name of the external port.
 Different types of Ethernet ports support different Working Modes, if the
opposite port works in auto-negotiation mode, set this parameter to
Auto-Negotiation. (Generally, Working Mode of the external equipment is set
to Auto-Negotiation.) For Ethernet ports within a network, set Working Mode
to Auto-Negotiation.
 Maximum Frame Length: Set this parameter to a value greater than the
maximum length of all the data frames to be transmitted. When jumbo frames
are transmitted, set Max Frame Length(byte) according to the actual length
of the jumbo frames. Otherwise, it is recommended that Max Frame Length
(byte) takes its default value.

 Notes: Set Tag Attributes to Tag Aware if the port allows the access of only the
tagged frames, set Tag Attributes to Access if the port allows the access of
only the untagged frames, after the frames come in the port, the port gave it
the default VLAN ID. If set Tag Attributes to Hybrid then the port allows the
access of the tagged frames and untagged frames.

Confidential Information of Huawei. No Spreading without Permission 26


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

 The network attribute of an Ethernet port can be set to UNI, C-Aware, or


S-Aware, depending on how the port processes C-TAGs and S-TAGs.

 Notes: An S-Aware port considers that a received packet contains an S-TAG. The
frame with only an S-TAG and a frame with a C-TAG and an S-TAG can normally
enter and exit an S-Aware port. If an untagged frame enters and exits an S-Aware
port, the port discards the frame.

Confidential Information of Huawei. No Spreading without Permission 27


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

 Source Port: When you create bidirectional Ethernet services from a PORT to a
VCTRUNK, it is recommended that you set the PORT to the source port.
 Source C-VLAN(e.g. 1,3-6): if this parameter is set to null, all the services at the
source port are used as the service source, If this parameter is not set to null,
only the service that carries a specified VLAN ID at the source port can be
used as the service source, then the port or VCTRUNK can sharing by
different VLAN ID. And the number of VLANs must be the same as the value
of Sink C-VLAN(e.g. 1,3-6).
 Sink S-VLAN: This parameter must be set to a numerical value. Only the
services of the sink port that S-VLAN IDs are equal to the value of this
parameter work as the service sink.
Notes: So can use same Source C-VLAN to sharing the VCTRUNK, just S-VLAN
is different enough.

Confidential Information of Huawei. No Spreading without Permission 28


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

3.3 Configure EPLAN Services


Step Action

Confidential Information of Huawei. No Spreading without Permission 29


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

2  Enable the Ethernet Port that need configure Ethernet service, and displays
or specifies the name of the external port.
 Different types of Ethernet ports support different Working Modes, if the
opposite port works in auto-negotiation mode, set this parameter to
Auto-Negotiation. (Generally, Working Mode of the external equipment is set
to Auto-Negotiation.) For Ethernet ports within a network, set Working Mode
to Auto-Negotiation.
 Maximum Frame Length: Set this parameter to a value greater than the
maximum length of all the data frames to be transmitted. When jumbo frames
are transmitted, set Max Frame Length(byte) according to the actual length
of the jumbo frames. Otherwise, it is recommended that Max Frame Length
(byte) takes its default value.

 Notes: Set Tag Attributes to Tag Aware if the port allows the access of only the
tagged frames, set Tag Attributes to Access if the port allows the access of
only the untagged frames, after the frames come in the port, the port gave it
the default VLAN ID. If set Tag Attributes to Hybrid then the port allows the
access of the tagged frames and untagged frames.

Confidential Information of Huawei. No Spreading without Permission 30


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

Confidential Information of Huawei. No Spreading without Permission 31


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

5  The equipment supports 802.1d bridges, 802.1q bridges, and 802.1ad


bridges. The services on different 802.1d bridges are separated, but the
services of different VLANs on the same bridge are not. So in 802.1d bridges,
the Bridge Switching Mode is set to SVL/Ingress Filter Disable, and no
need create VLAN ID filter table. Set Bridge Type as 802.q or 802.d.
 If the services on different 802.1q bridges and the services of different VLANs
on the same bridge are both separated, then the Bridge Switching Mode is
set to SVL/Ingress Filter Enable. So it is necessary to create VLAN ID filter
table.
 The services on different 802.1ad bridges and the services of different
S-VLANs on the same bridge are both separated. In 802.1ad bridges the
Bridge Switching Mode: if is set to SVL/Ingress Filter Disable, VLAN tags
are not checked. If is set to SVL/Ingress Filter Enable, S-VLAN tags are
checked. If the VLAN ID carried by a packet is not defined in the VLAN filter
table, the packet is discarded.

Confidential Information of Huawei. No Spreading without Permission 32


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

 If select an IEEE 802.1q or 802.1ad bridge then need click the VLAN Filtering
Table tab to create VLAN Filtering Table. If IEEE 802.1d bridge then no need
create VLAN Filtering Table.
 If we choose 1 as VLAN ID, it means the signal with VLAN=1 can be
forwarding between the ports.

Confidential Information of Huawei. No Spreading without Permission 33


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

Confidential Information of Huawei. No Spreading without Permission 34


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

Chapter 4 Configuring Native Ethernet Services

Steps Description Remarks

1 Configuring the Parameters of Ethernet Ports

2 Configuring the Parameters of IF_ETH Ports

3 Configuring LAGs

4 Configuring QinQ Links

5 Configuring E-Line Services

6 Configuring ERPS

7 Configuring 802.1d Bridge-Based E-LAN Services

8 Configuring 802.1q Bridge-Based E-LAN Services

9 Configuring 802.1ad Bridge-Based E-LAN Services

Confidential Information of Huawei. No Spreading without Permission 35


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

4.1 Configuring the Parameters of Ethernet Ports

Step Action

 If set Port Mode to Layer 2, Encapsulation Type can be set to Null, 802.1Q, or
QinQ. If you set Port Mode to Layer 3, Encapsulation Type can be set to 802.1Q
only. In this case, the port can be used to carry tunnel services.
 Encapsulation Type:
 For P2P E-Line services and IEEE 802.1d bridge-based E-LAN services, set
Encapsulation Type to Null.
 For VLAN-based E-Line services and IEEE 802.1q bridge-based E-LAN
services, set Encapsulation Type to 802.1q.
 For QinQ-based E-Line services and IEEE 802.1ad bridge-based E-LAN
services, set Encapsulation Type to Null if the UNI port allows access of
untagged frames; set Encapsulation Type to 802.1q if the UNI port allows
access of only tagged frames; set Encapsulation Type to QinQ in the case of
the NNI port.
 For an Ethernet port that is connected to the external equipment, set Working
Mode to a value the same as that of the external equipment (Generally, Working
Mode of the external equipment is set to Auto-Negotiation.) For Ethernet ports
within a network, set Working Mode to Auto-Negotiation.
 When jumbo frames are transmitted, set Max Frame Length(byte) according to the
actual length of the jumbo frames. Otherwise, it is recommended that Max Frame
Length(byte) takes its default value.

Confidential Information of Huawei. No Spreading without Permission 36


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

 For P2P E-Line services and IEEE 802.1d bridge-based E-Line services, you need
not set the Layer 2 attributes.
 For VLAN-based E-Line services and IEEE 802.1q bridge-based E-LAN services,
set Tag to Tag Aware if the port allows the access of only the tagged frames, set
Tag to Access if the port allows the access of only the untagged frames, and set
Tag to Hybrid if the port allows the access of the tagged frames and untagged
frames. Set Default VLAN ID and VLAN Priority according to the network planning
file.
 For QinQ-based E-Line services and IEEE 802.1ad bridge-based E-LAN services,
if the port functions as a UNI port and Encapsulation Mode is set to 802.1Q, Tag
must take its default value Tag Aware. For an NNI port that is connected to the
external equipment, set QinQ Type Domain according to the T-PID of the S-VLAN
that is supported by the external equipment. For an NNI port within the network,
QinQ Type Domain takes its default value.

Confidential Information of Huawei. No Spreading without Permission 37


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

 Under Advanced Attributes, set MAC Loopback, PHY Loopback and query the
port rate. This operation is mandatory when you need to enable the port self-loop
test and automatic loopback shutdown functions or to enable the broadcast packet
suppression function.
 Set Loopback Check, Loopback Port Shutdown, Enabling Broadcast Packet
Suppression, and Broadcast Packet Suppression Threshold according to the
requirements.
 Suggestions of Enabling Broadcast Packet Suppression:
 Enabling Broadcast Packet Suppression specifies whether to restrict the
traffic of broadcast packets according to the ratio of the broadcast packets to
the total packets. If a broadcast storm may occur on the equipment at the
opposite end, set this parameter to Enabled. For E-LAN services, it is
recommended that you set this parameter to Enabled. This parameter is
applicable to E-LAN services in the ingress direction.
 Speed Transmission at L2: If this parameter is set to Enabled, the Layer-2
Ethernet packets transmitted at microwave ports will be compressed to improve
transmission efficiency. If the Layer 2 header compression function can be enabled
for the ISU2 or ISX2 or ISV3 board, it is recommended that you set Speed
Transmission at L2 to Enabled. The settings of Speed Transmission at L2 must be
the same at both ends of a radio link.

Confidential Information of Huawei. No Spreading without Permission 38


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

4.2 Configuring the Parameters of IF_ETH Ports

Step Action

 If set Port Mode to Layer 2, Encapsulation Type can be set to Null, 802.1Q, or
QinQ. If set Port Mode to Layer 3, Encapsulation Type can be set to 802.1Q only. In
this case, the port can be used to carry tunnel services.If set Port Mode to Layer
Mix ,The port can carry mix service of layer 2 ad layer 3

Confidential Information of Huawei. No Spreading without Permission 39


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

 Under Advanced Attributes, set MAC Loopback and PHY Loopback and query the
port rate.
 If you set Speed Air Interface Transmission at L2 to Enabled, the Layer 2 Ethernet
packets received by the IF_ETH port are compressed for higher transmission
efficiency. The L2 packet header compression function is available for the
ISU2/ISX2/ISV3, it is recommended that you set Speed Air Interface Transmission
at L2 to Enabled for both ends of the link.
 If you set Speed Air Interface Transmission at L3 to Enabled, the IP packets
received by the IF_ETH port are compressed for higher transmission efficiency.
When the L3 packet header compression function is available for the
ISU2/ISX2/ISV3, it is recommended that you set Speed Air Interface Transmission
at L3 to Enabled for both ends of the link.

Confidential Information of Huawei. No Spreading without Permission 40


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

4.3 Configuring LAGs


Step Action

Confidential Information of Huawei. No Spreading without Permission 41


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

2  If set Port Mode to Layer 2, Encapsulation Type can be set to Null, 802.1Q, or
QinQ. If set Port Mode to Layer 3, Encapsulation Type can be set to 802.1Q only. In
this case, the port can be used to carry tunnel services.
 Automatically Assign: This parameter indicates whether LAG No. is allocated
automatically. When Automatically Assign is selected, LAG No. cannot be set.
 LAG Type:
 Static: You can create a LAG. When you add or delete a member port to or
from the LAG, the Link Aggregation Control Protocol (LACP) protocol is
required. In a LAG, a port can be in selected, standby, or unselected state.
The aggregation information is exchanged among different equipment
through the LACP protocol to ensure that the aggregation information is the
same among all the nodes.
 Manual: You can create a LAG. When you add or delete a member port, the
LACP protocol is not required. The port can be in the up or down state. The
system determines whether to aggregate a port according to its physical
state (UP or DOWN), working mode, and rate.
 Load Sharing:
 Sharing: Each member link of a LAG processes traffic at the same time and
shares the traffic load. The sharing mode can increase a bandwidth utilization
for the link. When the LAG members change, or certain links fail, the system
automatically re-allocates the traffic.
 Non-Sharing: Only one member link of a LAG carries traffic, and the other link is in
the standby state. In this case, a hot backup mechanism is provided. When the
active link of a LAG is faulty, the system activates the standby link, thus preventing
link failure.
 Load Sharing Hash Algorithm:This parameter is valid only when Load Sharing of
a LAG is set to Sharing. After the configuration data is deployed, Load Sharing
Hash Algorithm takes effect for the entire NE. For PW-carried UNI-NNI E-Line
services, Load Sharing Hash Algorithm cannot be set to MPLS Label.
 System Priority:This parameter indicates the priority of a LAG. The smaller the
value of System Priority, the higher the priority.
 Switch LAG upon Air Interface SD:This parameter specifies whether to enable the
switching triggered by bit errors. If this parameter is set to Enabled, the
MW_BER_SD alarm will trigger the LAG switching at the air interface.
Main Port:This parameter specifies the main port in a LAG. After a LAG is created,
you can add Ethernet services to the main port only. Services cannot be added to a
slave port. When Load Sharing is set to Non-Sharing, the link connected to the
main port is used to transmit the services, and the link connected to the slave port
is used for protection.

Confidential Information of Huawei. No Spreading without Permission 42


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

4.4 Configuring QinQ Links


Step Action

 QinQ Link ID:The OptiX RTN 900 supports 1024 QinQ links, whose IDs must be
different from each other.
 S-Vlan ID: This parameter specifies the VLAN ID (at the network operator side) for
the QinQ link. This parameter is set according to the planning information.

Confidential Information of Huawei. No Spreading without Permission 43


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

4.5 Configuring E-Line Services

Step Action

Confidential Information of Huawei. No Spreading without Permission 44


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

2  BPDU:This parameter specifies the transparent transmission ID of the bridge


protocol data unit (BPDU) packets. It is used to indicate whether the E-Line service
transparently transmits the BPDU packets. If the BPDU packets are used as the
service packets and transparently transmitted to the opposite end, set this
parameter to Transparently Transmitted. That is, the parameter value
Transparently Transmitted takes effect only if Encapsulation Type of the source
and sink ports of the E-Line service are Null. In other cases, set this parameter to
Not Transparently Transmitted. This parameter is set according to the planning
information.
 If Source VLAN ID and Sink VLAN ID are blank, it indicates that you create a
point-to-point transparently transmitted E-Line service. If you need to create a
VLAN-based E-Line service, enter the VLAN IDs as planned.
Set Direction to UNI-UNI. For QinQ-based E-Line services, set Direction to UNI-NNI.

 The VLAN ID of the UNI-UNI E-Line service can be converted after a VLAN
forwarding table item is created. In this case, a service from Source Interface to
Sink Interface carries the VLAN ID specified in Sink VLAN ID when the service is
transmitted from Sink Interface.
 The VLAN ID in a VLAN forwarding table item is converted unidirectionally and
can be converted from Source VLAN ID to Sink VLAN ID only. The VLAN ID can be
converted bidirectionally only when the other VLAN forwarding table item is
configured reversely.
 In normal cases, Ethernet services are bidirectional. Hence, you need to set
bidirectional conversion of VLAN IDs.

Confidential Information of Huawei. No Spreading without Permission 45


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

4.6 Configuring ERPS

Step Action

Confidential Information of Huawei. No Spreading without Permission 46


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

2  ERPS ID: Set ERPS ID to a value between 1 and 8. The ERPS ID must be unique.
 RPLOwner Ring Node Flag:This parameter specifies whether the node on the ring
is the ring protection link (RPL) owner. Only one node on the ring can be set as the
RPL owner for each Ethernet ring.
 RPL Port:There is only one RPL port and this RPL port must be the east or west
port on the RPL owner node.
 Control VLAN:It is used for isolating the dedicated R-APS channel. Therefore, the
VLAN ID in Control VLAN cannot be duplicate with the VLAN IDs that are
contained in the service packets. The Control VLAN must be set to the same value
for all the NEs on an ERPS ring.
 Destination Node: This parameter indicates the MAC address of the destination
node. The default destination MAC address in the R-APS packets is always
01-19-A7-00-00-01.
 Hold-Off Time(ms): It is used for negotiating the protection switching sequence
when the ERPS coexists with other protection schemes so that the fault can be
rectified in the case of other protection switching (such as LAG protection) before
the ERPS occurs. If only ERPS protection is configured, set Hold-Off Time(ms)to 0.
If ERPS protection is configured with LAG, set Hold-Off Time(ms) to 500.
 Guard Time(ms): The nodes on the ring continuously forward the R-APS packets to
the Ethernet ring. As a result, the outdated R-APS packets may exist on the ring
network. After a node on the ring receives the outdated R-APS packets, an
incorrect ERPS may occur. The ERPS guard timer is an R-APS timer used for
preventing a node on the ring from receiving outdated R-APS packets. When a
faulty node on the ring detects that the switching condition is cleared, the node
starts up the guard timer and starts to forward the R-APS (NR) packets. During this
period, the R-APS packets received by the node are discarded. The received R-APS
packets are forwarded only after the time of the guard timer expires.
 WTR Time(mm:ss) The WTR time refers to the duration from the time when the
working channel is restored to the time when the switching is released. When the
working channel is restored, the WTR timer of the RPL owner starts up. In addition,
a signal that indicates the operation of the WTR timer is continuously output in the
timing process. When the WTR timer times out and no switching request of a
higher priority is received, the signal indicating the operation of the WTR timer is
not transmitted. In addition, the WTR release signal is continuously output. The
WTR timer is used to prevent frequent switching caused by the unstable working
channel.
 Packet Transmit Interval(s): It specifies the interval for transmitting the R-APS
packets. It is recommended that this parameter take its default value.

Confidential Information of Huawei. No Spreading without Permission 47


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

4.7 Configuring 802.1d Bridge-Based E-LAN Services

Step Action

Confidential Information of Huawei. No Spreading without Permission 48


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

 Tag Type:
 C-Awared: indicates that the packets are learnt according to C-Tag (the
VLAN tag on the client-side). To create the 802.1q bridge, set this parameter
to C-Awared.
 S-Awared: indicates that the packets are learnt according to S-Tag (the
VLAN tag at the carrier service layer). To create the 802.1ad bridge, set this
parameter to S-Awared.
 Tag-Transparent: indicates that only the Ethernet packets that do not
contain VLAN tags are accessed. To create the 802.1d bridge, set this
parameter to Tag-Transparent.
 Self-Learning MAC Address: If the MAC self-learning function of an Ethernet LAN
is enabled, the Ethernet LAN learns an MAC address according to the original MAC
address in the packet and automatically refreshes the MAC address forwarding
table. If the MAC self-learning function of an Ethernet LAN is disabled, a static
MAC address forwarding table is recommended to be configured.
 MAC Address Learning Mode: When the bridge uses the SVL mode, all the VLANs
share one MAC address table. If the bridge uses the IVL mode, each VLAN has an
MAC address table.

Confidential Information of Huawei. No Spreading without Permission 49


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

 Split Horizon Group Member: The OptiX RTN 900 supports only the division of the
split horizon group members according to the Ethernet physical port. If a UNI or
NNI logical port of the 802.1ad bridge is added to a split horizon group member,
the physical port that is mounted with the logical port is automatically added to the
split horizon group member.
 NOTES: To better isolate services that are converged and to prevent broadcast
storm resulting from a service loop, you can configure a split horizon group for the
E-LAN services at the specified nodes. The logical ports in one split horizon group
cannot forward packets to each other.

Confidential Information of Huawei. No Spreading without Permission 50


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

4.8 Configuring 802.1q Bridge-Based E-LAN Services

Step Action

 NOTES: Set Tag Type to C-Awared. Set VLAN(1,3-5) of each port according to the
network planning file.

Confidential Information of Huawei. No Spreading without Permission 51


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

4.9 Configuring 802.1ad Bridge-Based E-LAN Services

Step Action

 Port Type: PORT or PORT+C-VLAN (UNI port); PORT+S-VLAN (NNI port).


NOTES: NOTES: Set Tag Type to S-Awared. Set C-VLAN(1,3-5) or S-VLAN of each
port according to the network planning file.

Confidential Information of Huawei. No Spreading without Permission 52


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

Task1 Basic Configuration


1. Knowledge requirement
You need to familiar with the operations in charter 1 (Radio link configuration).

2. Scenario description

There are 2 NEs (NE A and NE B) in the network, the equipment can be
RTN910/950/980, each NE has two IF boards and ODUs.
It is recommended to use the NE default ID and IP.
The transmitting freq. range and T/R spacing of ODU can be got from the label on
the ODUs.

3. Configuration requirement
a) Configure the radio link between NEA and NEB with the 1+1 HSB protection.
b) Configure the radio link between NEA and NEB with the 1+1 FD protection.
c) Configure the radio link between NEA and NEB with the 1+1 SD protection.
d) Configure the radio link between NEA and NEB with the N+1 (N=1) protection.
e) (Optional) If the IF board is IFX2/ISX2/ISV3, please configure the XPIC function.

NOTES: Please make sure there is no abnormal alarm happens; Delete the previous
protection data after finish each requirement;

Confidential Information of Huawei. No Spreading without Permission 53


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

Task2 TDM Services Configuration


1. Knowledge requirement
You need to familiar with the operations in charter 1 (Radio link configuration) and
charter 2 (TDM Services Configuration).

2. Scenario description

There are 3 or 4 NEs in the network, the equipment can be RTN910/950/980, NEA
and NEB has two IF boards and ODUs.
It is recommended to use the NE default ID and IP.
The transmitting freq. range and T/R spacing of ODU can be got from the label on
the ODUs.

3. Configuration requirement
NE A is added in SDH ring by port 1&2 of SL1D, there are 8 x E1 services between NE
B and SDH equipment. The services are protected by 1+1 HSB in radio link, and
SNCP in the SDH ring.

NOTES: Please make sure there is no abnormal alarm happens;

Confidential Information of Huawei. No Spreading without Permission 54


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

Task3 EoPDH-Based EPL Services Configuration


1. Knowledge requirement
You need to familiar with the operations in charter 1&2&3.

2. Scenario description

There are 2 NEs (NE A and NE B) in the network, the equipment can be
RTN905/910/950/980, NEA and NEB has two IF boards and ODUs.
There is the Ethernet service of company A between NEA and NEB.
It is recommended to use the NE default ID and IP.
The transmitting freq. range and T/R spacing of ODU can be got from the label
on the ODUs.

3. Configuration requirement
a) There are 5 x E1 services between NEA and NEB. The services are
protected by 1+1 HSB in radio link;
b) There is the EoPDH service of company A between NEA and NEB;

NOTES: Please make sure there is no abnormal alarm happens;


Connect the computers between the two ends of company A, use the
Ping function to check the Ethernet service.

Confidential Information of Huawei. No Spreading without Permission 55


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

Task4 EoPDH-Based EPLAN Services Based-on


Configuration
1. Knowledge requirement
You need to familiar with the operations in charter 1&2&3.

2. Scenario description

There are 2 NEs (NE A and NE B) in the network, the equipment can be
RTN905/910/950/980, NEA and NEB has two IF boards and ODUs.
One company has three branches connected to NE B by 3 ETH ports,
headquarter is connected to NE A by ETH port also.
It is recommended to use the NE default ID and IP.
The transmitting freq. range and T/R spacing of ODU can be got from the label
on the ODUs.

3. Configuration requirement
a) VLAN ID 1 is used in the whole company for intranet. Headquarter
communicates with branch A by VLAN ID 1&2, branch B by VLAN ID 1&3,
branch C by VLAN ID 1&4. And except VLAN ID 1, there is not
communication among branches via other VLAN.
b) The Ethernet Services are carried by Board EFP8, and select the IEEE
802.1q Bridge.

NOTES: Please make sure there is no abnormal alarm happens;

Confidential Information of Huawei. No Spreading without Permission 56


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

Task5 Configuring Point-to-Point Transparently


Transmitted E-Line Services
1. Knowledge requirement
You need to familiar with the operations in charter 1&2&3&4.

2. Scenario description

There are 2 NEs (NE A and NE B) in the network, the equipment can be
RTN905/910/950/980, NEA and NEB has two IF boards and ODUs.
There is the Ethernet service of company A between NEA and NEB.
It is recommended to use the NE default ID and IP.
The transmitting freq. range and T/R spacing of ODU can be got from the label
on the ODUs.

3. Configuration requirement
a) There are 5 x E1 services between NEA and NEB. The services are
protected by 1+1 HSB in radio link;
b) There is the Point-to-Point Transparently Transmitted E-Line service of
company A between NEA and NEB;

NOTES: Please make sure there is no abnormal alarm happens;


Connect the computers between the two ends of company A, use the
Ping function to check the Ethernet service.

Confidential Information of Huawei. No Spreading without Permission 57


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

Task6 Configuring VLAN-Based E-Line Services


1. Knowledge requirement
You need to familiar with the operations in charter 1&2&3&4.

2. Scenario description

There are 2 NEs (NE A and NE B) in the network, the equipment can be
RTN905/910/950/980, NEA and NEB has two IF boards and ODUs.
There is the Ethernet service of company A between NEA and NEB.
It is recommended to use the NE default ID and IP.
The transmitting freq. range and T/R spacing of ODU can be got from the label
on the ODUs.

3. Configuration requirement
a) There are 5 x E1 services between NEA and NEB. The services are
protected by 1+1 HSB in radio link;
b) There is the VLAN-Based E-Line service of company A between NEA and
NEB;

NOTES: Please make sure there is no abnormal alarm happens;


Connect the computers between the two ends of company A, use the
Ping function to check the Ethernet service.

Confidential Information of Huawei. No Spreading without Permission 58


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

Task7 Configuring QinQ-Based E-Line Services


1. Knowledge requirement
You need to familiar with the operations in charter 1&2&3&4.

2. Scenario description

There are 2 NEs (NE A and NE B) in the network, the equipment can be
RTN905/910/950/980, NEA and NEB has two IF boards and ODUs.
There is the Ethernet service of company A between NEA and NEB.
It is recommended to use the NE default ID and IP.
The transmitting freq. range and T/R spacing of ODU can be got from the label
on the ODUs.

3. Configuration requirement
a) There are 5 x E1 services between NEA and NEB. The services are
protected by 1+1 HSB in radio link;
b) There is the QinQ-based E-Line service of company A between NEA and
NEB;

NOTES: Please make sure there is no abnormal alarm happens;


Connect the computers between the two ends of company A, use the
Ping function to check the Ethernet service.

Confidential Information of Huawei. No Spreading without Permission 59


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

Task8 802.1d Bridge-Based E-LAN Services


1. Knowledge requirement
You need to familiar with the operations in charter1&2&3&4.

2. Scenario description

There are 2 NEs (NE A and NE B) in the network, the equipment can be
RTN905/910/950/980, NEA and NEB has two IF boards and ODUs.
One company has three branches connected to NE B by 3 ETH ports, headquarter is
connected to NE A by ETH port also.
VLAN ID 1 is used in the whole company for intranet.
It is recommended to use the NE default ID and IP.
The transmitting freq. range and T/R spacing of ODU can be got from the label on
the ODUs.

3. Configuration requirement
a) There are 8 x E1 services between NEA and NEB. The services are protected by
1+1 HSB in radio link;
b) There is the E-LAN services between headquarter and branches;
c) The branches can communicate with HQ only, and there is not any
communication among branches.

Confidential Information of Huawei. No Spreading without Permission 60


Error! Use the Home tab to apply 标题 1 to
OptiX RTN 900 Data Configuration (Hybrid Domain) the text that you want to appear here.

NOTES: Please make sure there is no abnormal alarm happens;

Task9 802.1q Bridge-Based E-LAN Services

1. Knowledge requirement
You need to familiar with the operations in charter1&2&3&4.

2. Scenario description

There are 2 NEs (NE A and NE B) in the network, the equipment can be
RTN910/950/980, NEA and NEB has two IF boards and ODUs.
One company has three branches connected to NE B by 3 ETH ports, headquarter is
connected to NE A by ETH port also.
It is recommended to use the NE default ID and IP.
The transmitting freq. range and T/R spacing of ODU can be got from the label on
the ODUs.

3. Configuration requirement
c) VLAN ID 1 is used in the whole company for intranet. Headquarter
communicates with branch A by VLAN ID 1&2, branch B by VLAN ID 1&3,
branch C by VLAN ID 1&4. And except VLAN ID 1, there is not communication
among branches via other VLAN.

Confidential Information of Huawei. No Spreading without Permission 61


OptiX RTN 900 Data Configuration (Hybrid Domain) Error! Use the Home tab to apply 标题 1 to
the text that you want to appear here.

NOTES: Please make sure there is no abnormal alarm happens;

Confidential Information of Huawei. No Spreading without Permission 62

S-ar putea să vă placă și