Sunteți pe pagina 1din 15

High Technology

CATV and Communication


Products

CATV ELITE

GAD Series CATV System


1550nm Optical Fiber Amplifier

Operation Manual

Chengdu KT Electronic Hi-Tech Co., Ltd


Warning
Please read the manual carefully before using the device.
To prevent the risk of electric shock, do not remove the cover. There are no parts inside
that user can repair. Please refer to qualified service personnel for repair.

The mark reminds the user that there might be hazardous


live which can generate enough energy to cause the risk of
electric shock

The mark reminds the user concerning important


components and safe operation.

The mark reminds user that avoid the laser light radiating
eye directly. That may injure your eye.

The mark reminds user that the device must be grounded


reliably.

Safety
 It’s a class Ⅰ device; Ground logo indicates that the device must be grounded reliably.

 Power supply: AC 50Hz 150V~265V.3

 To ensure the safety of the products and the network, please make the metal crust and

conductor grounded.

 Please ask professional person to debug after installation. Pay attention to CAUTION logos

when using.

Installation
 Please refer to the latest installation direction. Away from high temperature and frequent

shake.

 The installation sketch map indicates positions of the connectors, just for reference.

 To ensure waterproof performance, screw the bolts tightly after installation.

Repack
 Retain the original carton and packing materials for safe transport in the future.
1
Content

1.Brief introduction ………………………………………………………… 3

2.Feature……………………………………………………………………………3

3.Main application ………………………………………………………………3

4.Principle diagram…………………………………………………………………3

4.External structure …………………………………………………………4

5 . Pan el ………………………………………………………………………4

6. Technical specification …………………………………………………………5

7.Menu……………………………………………………………………………6

8.Web monitoring and parameter settings………………………………………9

8.Installation……………………………………………………………………13

9.Troubleshooting …………………………………………………………14

10.Maintenance …………………………………………………………………14

2
Brief introduction
GAD series product is a C-Band Power Amplifier. It’s mainly designed for single-channel or
multi-channel continuous ribbon channels (ITU wavelength). GAD series power amplifiers features
low noise figure and high saturated output power, it fits to central office, branch and line relay, you
can also use other optical fiber communication networks; It’s the most common and largest
amount amplifier in CATV system. The GAD series erbium-doped fiber amplifier adopts the world's
top brands pumped erbium-doped fiber. Perfect APC and ATC control, good ventilation design to
ensure long life and high reliability of PUMP Laser. The front panel LCD provides machine
operating parameters and alarm; lasers automatically turn off when missing optic to protect laser
safety; RJ45 interface provides SNMP-based network management interface; high quality, high
reliability and excellent cost performance, is ideal for system integrators and network operators.

Feature
● 19”1U standard chassis with LCD on front panel
● Low noise figure
● High-power output
● Input/output optoisolator
● High reliability pump laser (980/1480nm)
● Laser APC/ACC/ATC control circuit
● SNMP network management function
● Modular power supplies, dual power supply hot backup

Main application
● AM CATV

● Digital CATV

● DBS MMDS Fig1 Outline drawing

● FTTH

3
Principle diagram

Fig2 Principle diagram

Panel
1. Front panel

Fig3 Front panel


1) Company LOGO

2) LCD, displays machine working parameter, check or set related content by page up, page

down and OK button

3) View the parameters on LCD and set network parameter by page up/down and OK button

4) The optical signal index lights, green light when the input optical power matches the input

range, red when the input optical power is below the set value (default factory-3dBm), users

can set the parameter threshold through network management software or WEB page

5) Alarm indicator, green light when normal machine parameters, red light when parameters

4
exceed the set range, the user can view the alarm information through the keys, "alarm"

symbol will appear next to the parameters of the alarm

6) PWR 1 and PWR2 indicate the working status of PWR1 and PWR2, green lights when

working normal

7) Laser switch, "ON" when laser is open and "OFF" when the laser is turned off, regardless of

the laser is "ON" or "OFF", the laser will be turned off when the input optical power is lower

than the set value (default factory-3dBm)

2. Rear panel

Optical IN Optical OUT LAN PWR1 PWR2

Fig4 Rear panel


1) Optical input and output port default SC/APC, FC/APC optional

2) LAN port, SNMP network management port, 10/100M adaptively

3) PWR1, PWR2, 150V~265V input AC power, load sharing work mode, hot swap

Technical Specification
Table1 technical specification
Parameter MIN. TYP MAX. Remark

Working wavelength(λ) (nm) 1540 1563

Input optical power


(dBm) -3 +3 +10
range

Output power (dBm) +18 +24 PIN=0dBm

NF (dB) 4.5 6.0 PIN=0dBm


Optical
PDL (dB) 0.1 0.3
characteristic
PDG (dB) 0.5

PMD (PS) 0.5

Pump leakage power (dB) -30

Input return loss (dB) 45

5
Output return loss (dB) 45

Optical connection port SC/APC,FC/APC

type optional

Communication port RJ45

Power supply (V) AC 150~265

General
Power consumption (W) ≤20
characteristic
Working temperature (℃) 0~50

Storage temperature (℃) -40~85

Relative humidity (%) 5~95

Dimension (mm) 430×360×39 1U(W)×(D)×(H)

Above technical specifications may be changed without notice.

Menu
Boot menu

KINGTYPE GROUP
EDFA

Boot interface is as shown above. User can enter functional menu and submenus by pressing

[↓] / [↑] or [Enter] key. The LCD backlight will be turned off if there is no operation for 60 seconds.

Press any key to re-lit.

Function menu

Optical Info

Press [↓] to move on to the first-level Menu—“Optical Info”—it displays optical power.

There are “Input Power” and “Output Power” under this menu. A s be shown in the following

figure.

Input Power: Output Power:


+3dBm OK +20.1dBm OK
6
Press [↓] again and there is “Return” menu. Press "ENTER" to exit and enters “Pump Info”.

Return [ENT]

Pump Info

The menu displays the pump information, including "Pump Current" (working current), "Pump

Power" (output power), "Pump Cooler" (cooling current), "Pump Temp" (working temperature), as

shown below:

Pump Current: Pump Cooler:


550mA 150mA

Pump Temp:
25℃

Power Info

“Power Info” is consist of four sub-menus: "Power1 +5 V", "Power1 -5V", "Power2 +5 V"

and "Power2 -5V". They respectively show the ± 5V power value of power module 1 and power

module 2, as shown below:

Power1 +5V: Power1 -5V:


5.2V -5.1V

Power2 +5V: Power2 -5V:


5.3V -5.1V

“System Info” includes "Module" (product model), "Pout Rating" (nominal power), "SN"

7
(factory serial number) and "EDFA Temp" (machine temperature), as shown below:

System Info

Module: S/N:
GAD2002SM KT09080011

EDFA Temp:
31.0℃

“Network Config” includes two submenus: “View” and “Setup”. The former one provides

parameter browsing and the latter provides configuring. As shown below:

Network Config
View [Setup]

Enter [Setup] and press [↓] or [↑] key to choose the parameter that you want to modify.

Press [Enter] to change value; move the cursor to the SAVE "YES" to save the settings or move to

"NO" to cancel and exit, as shown below:

IP Address: ■0.002.018.215
10.2.18.215 Save [YES] NO

Subnet Mask: ■55.255.255.000


255.255.255.0 Save [YES] NO

Gate Way: ■0.018.002.001


10.18.2.1 Save [YES] NO

Trap Address1: ■0.002.018.239


10.2.18.239 Save [YES] NO

8
Web monitoring and parameter settings

Fig5
●Operator Login
An operator must login first, and then he can change the parameters. Initial password is
"kt123", username "ktwg". User can change the password after login.
● IP address
This column shows the IP address of the system work
● MAC address
This column shows the physical address of the responder.
●Current status
This column shows the system messages, such as system working properly, system alarm,
temporary IP address 192.168.1.1 (instructions: When press Reset button, IP address will be
forced to set to 192.168.1.1. Note: This IP address is temporary, after 4 minutes or off electricity, it
will automatically revert to the IP address before the reset.)
●Device model
It shows the model of the device. (Note: It may be inconsistent with the label on the product
nameplate)
●Power type
It shows the power supply type of the device (AC 220V).
●Parameter table
It shows the current status and parameters values of the device.

9
IP address setting

Notice that if IP address of the device is conflicting with any of the other devices, it will
interrupt communications.

Password setting

The password digits should not be more than 8 characters, otherwise it is set to invalid and
user name can not be set, the system defaults to the lowercase "ktwg". Keep the password in
mind after the password is set. If the password is lost, please call us (Telephone and Email
address are prompted in red on the home page, you can see in the first 20 seconds when Log in
Home).

10
Alarm Enable Setting

Alarm enable setting, when the user selects the parameters of the corresponding option. It will
alarm if the actual value of the parameter exceeds the set alarm threshold.

Alarm Level

Alarm threshold settings, in actual use, the user can adjust the alarm threshold according to
the actual situation. (Note: Users do not have to set the threshold of these parameters, the device
has been set at the factory default threshold values of these parameters), a little high and low for
general alarm, low and high for serious alarm.

11
Trap IP

The Trap receiver address allows up to four, the address is enabled when settings enabled

address option is selected.

Restore

When the alarm enable or alarm threshold settings disorder, if you want to restore the factory
settings, restore to factory settings after clicking the confirmation button. (Note: to restore the
factory settings, IP addresses will not be affected.)

12
Installation

 Box inspection
KT GAD Series 1550 optical fiber amplifier has been strict production debugging and testing

before leaving the factory, with user manual and random accessories in the box. After receipt of

the goods, user should first check whether the box is in good condition, and then open it to check

whether the machinery and equipment is damaged in transit, or random accessories are complete,

and timely feedback to KT Company. (Contacts please see the last page)

 Installation
1. The equipment uses 220v AC power supply, the fuse specifications 1.6A, to be ensure that the
shell is well grounded.
2. Before use, check wavelength and power of the input signal of the optical interface, to ensure
that it’s within the range of specified operating parameters.
3. Clean the external input/output pigtail connector end face, clean as follows: wipe with a clean
dedicated dust-free paper, slightly moistened with pure alcohol wipe 2-3 times. Be residues after
the alcohol evaporates, and the external jumper can be connected to the EDFA input/output
optical port, and to ensure a good connection.
4. Check whether the power connection and the input/output jumper connections are correct, turn
on the power switch on the front panel, the power LED is lit, the key that unlocks the panel laser,
no panel alarm indication, EDFA already normal work; any time plug input/output pigtail, user
must first disconnect the power to ensure personal safety.
5. If user wants to monitor EDFA work status, connect LAN port of EDFA and PC, and select the
corresponding PC software, you can read EDFA work.

13
Troubleshooting
Table 2

No. Failure Reason Solution


1. Power cable 1. Make sure that the power cable
connection is bad, or and socket contacts, or turn on the
All indicator off the power switch is not power switch;
1
turned on; 2. Replacement of the same
2. The fuse has blown specification fuse
3. Power supply failure 3. Replace the power supply
1. No optical power
input
2. Input connector did 1. Check the previous optical
not answer transmitter device
2 LASER indicator red 3. The end face of 2. Re-connect
3. Replace the pigtail
connector is bad
4. Open EDFA key
4. EDFA key is not
open;
1、 The corresponding
power supply cord
1、 Plug in the power cord, turn on
is not connected,
POWER1, POWER2 the switch
3 or the switch is off
indicator red 2、 Replacement the power supply
2、 The corresponding
of the same specifications
power supply
damaged
1、Pump temperature
exceeds the set range Check whether the network
management software
2、Pump bias current
4 ALARM indicator red corresponding parameter setting
exceeds the set range range is too small.
3、Pump bias current
exceeds the set range

Maintenance
 Not allowed to work in the acidic, alkaline and high temperature environment
 Stick with a soft material economic neutral detergent to clean the chassis
 Prevent heavy bump, heavy fall and heavy vibration.
KTSM0497/2013-11-16

Chengdu KT Electronic Hi-tech Co., Ltd


Add: No.9, 3rd East Wuke Road, Wuhou District, Chengdu Zip code: 610045
Tel: 0086-28-85360759 Fax: 0086-28-85369640
Email:oversea@ktcatv.com http://www.ktcatv.com

14

S-ar putea să vă placă și