Sunteți pe pagina 1din 2

Alternate 3-way Switch Installation:

MODEL LST700 / LST700+ 7-DAY DIGITAL WALL SWITCH TIMER


INSTALLATION & OPERATING INSTRUCTIONS

Introduction

The LST700 / LST700+ can replace your regular or 3-way switch (where two
switches control the same device) to control a light or any device plugged into
an outlet with a load up to 15 Amps; the maximum rating on the timer label.
9. For alternate 3-way Switch Installation, connect each wire as shown
The LST700 / LST700+ also has an exclusive manual On-Demand Delayed above.
OFF mode that enables the user to leave the room while the light is ON and the 10. Tuck the wires into the wall box leaving room for the timer. BE SURE that
timer automatically shuts the load OFF after a preset amount of time without ALL the WIRE NUTS are TIGHT and SECURE.
interfering with programmed AUTOMATIC times or controls. 11. Using the screws provided, mount the timer securely to the wall box then
install the wall plate.
The LST700 / LST700+ timer can control incandescent lights, compact 12. Return the power to the circuit at the service panel. The display will blink
fluorescent lights, fluorescent lights, flood lights, LED lights, fans and motors. all characters and icons; see Operating Instructions to program the
device.
You will need to use a Decorator style wall plate with this timer which is not
supplied.
Controls
The timer must be mounted into a standard single or multi-ganged electrical
box.

Read wiring instructions carefully and follow guidelines applicable to your


installation.

WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH


APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
WARNING: IF YOU ARE UNSURE ABOUT ANY PART OF THESE
INSTRUCTIONS CONTACT A QUALIFIED ELECTRICIAN.
WARNING: TO AVOID FIRE, SHOCK OR DEATH; TURN OFF POWER AT
CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF
BEFORE WIRING!
WARNING: DO NOT EXCEED THE 625 WATT INCANDESCENT RATING OF
THIS DEVICE.
CAUTION: USE THIS DEVICE WITH COPPER OR COPPER CLAD WIRE.
WITH ALUMINUM WIRE USE ONLY DEVICES MARKED CO/ALP OR CU/AL.
Operating Modes
INSTALLATION INSTRUCTIONS:
Single Pole Switch or 3-way to replace an existing switch: The LST700/LST700+ has 4 operating modes. The Mode switch determines
which mode you are in
1. TURN OFF POWER by REMOVING FUSE or turning the CIRCUIT
BREAKER OFF. 1. MAN / PRGM (Manual / Program) this mode allows the setting of the Clock
2. Remove the existing wall switch. time, Weekday and the Timer ON and OFF times. In this position the
automatic timer function is disabled.
Single Switch (Single Pole Installation): 2. VARI (Variable) in this mode the timer is enabled and the ON and OFF
time settings will be altered plus or minus 15 minutes to confuse possible
3. Connect the BLACK building wire from the Main Power Panel to the intruders. (ON & OFF times must be at least 16 minutes after one another
BLACK wire from the timer, using the wire nuts provided. Connect the for this feature to operate correctly.)
BLUE wire from the timer to the BLACK wire going to the load. Connect 3. AUTO RUN (Automatic Run) in this mode the timer ON and OFF settings
together the WHITE wire from the main power cable to the WHITE wire are enabled as programmed.
from the timer and the WHITE wire to the load. 4. Delayed OFF Mode. See Operation of Delayed OFF Mode below. The
THE RED WIRE IS NOT USED FOR SINGLE SWITCH INSTALLATIONS. position of the Mode switch is irrelevant.
Cap the RED wire with a wire nut. This wire MUST BE CAPPED
SECURELY. Rocker Switch
BE SURE that ALL the WIRE NUTS are TIGHT and SECURE.
The rocker switch at the base of the unit will override any current settings. If the
device is ON, the switch will turn it OFF; if OFF, it will turn the device ON.

If the device is in Delayed OFF mode and the light is ON, the switch will turn the
light OFF.

OPERATING INSTRUCTIONS:

Set Current Clock Time and Day of Week

NOTE - The current clock time and day of week must be correctly set first
or you can not program the timer ON or OFF time events.
1. Position the Display slide switch to the Middle position of CLK SET (Clock
Set).
3-way Switch Installation: 2. Position the Mode slide switch to Left position of MAN/PRGM (Manual /
4. A three way switch has three wires connected to it. One of the wires is Program)
“common” (the terminal has a different colored screw or there are 3. Depress the UP or DOWN button and hold for 2 seconds, the ON/OFF
markings on the old switch). Connect the BLACK wire from the timer to icons and all Day of Week (DOW) icons will blank and the clock time will
the common wire, Connect the other two wires to the BLUE and RED begin to scroll slowly in the direction you have selected. After 5 seconds,
wires from the timer (it doesn’t matter which goes to which.) the time will scroll rapidly. There is an AM / PM indicator that will appear
5. Connect together the WHITE wire from the main power cable to the to indicate morning or evening. Ensure AM or PM is set correctly. Release
WHITE wire from the timer and the WHITE wire to the load. Button.
6. Tuck the wires into the wall box leaving room for the timer. BE SURE that 4. After setting the Current Clock Time, wait 5 seconds and the Clock Time
ALL the WIRE NUTS are TIGHT and SECURE. will disappear and all Day of Week Icons (DOW) will blink. Depress the UP
or DOWN button to scroll left or right to set the Current Day of the Week.
(Icon days, from left to right are: Sunday, Monday, Tuesday, Wednesday,
Thursday, Friday, Saturday (S M T W T F S)

Reset
Holding down both the UP and DOWN buttons simultaneously for 5 seconds will
completely reset the timer. (All programmed events, current time and day of
week will be cleared.) The display will blink all characters and icons and the
timer will need to be re-programmed as stated above, including all ON/OFF
Events.

Note: During a power failure the LCD screen display will be blank. When the
power is restored the Clock Time and Day of Week will be re-displayed.

Set Timer ON / OFF times:


7. Using the screws provided, mount the timer securely to the wall box then
install the wall plate.
8. Return the power to the circuit at the service panel. The display will start When programming ON/OFF Events, all days of the week are indicated by
flashing all icons; see Operating Instructions to program the device. default and will blink. The display will have a lowercase “d” and either all Day of
Week icons lit or a single Day of Week indicating you are programming that
particular Day of Week.
Setting the ON and OFF times is referred to as Events 1 & 2 (E:1 & E:2) on the The Model LST700 / LST700+ Digital Wall Switch Timer is capable of leaving
display. When the Mode switch is placed in the Manual / Program position the the light or load ON while leaving a room or building and automatically turning
display will show the Day and Event(s) to be programmed. the light OFF after a factory pre-set amount of time after 10 minutes without
user programming. This function does not interfere with any pre-programmed
To program all seven (7) days of the week the same: times or cycles.
1. Move the Display slide switch to the Right position to TIME ON.
2. Move the Mode slide switch to the Left position to MAN/PRGM (Manual / NOTE - The clock time and current day of week must be set first or you
Program) position. The display will have a lowercase “d” and all Days of cannot use the Delayed OFF mode. If the Timer is in an automatic ON
Week icons will blink indicating you are programming all Days of Week the cycle, the Delayed OFF mode will not function.
same.
3. After 5 seconds, the timer will automatically enter Event 1 (E:1) program 1. The manual Delayed OFF mode is activated by ANY two consecutive
mode. transitions of one (1) second or less of the Rocker Switch. The position of
4. Depress the UP or DOWN button and hold for 2 seconds, the time will the Display switch or Mode switch is irrelevant. i.e., If the load is ON, turn
begin to scroll slowly in the direction you have selected. After 5 seconds, the Rocker Switch OFF then ON or if the load is OFF, then turn the Rocker
the time will scroll rapidly. There is an AM / PM indicator on the top right Switch ON then OFF quickly.
of the display that will appear to indicate a morning or evening setting. 2. The display will show a factory pre-set count down value of ten (10)
5. Move the Display slide switch to the Left position to TIME OFF for Event 1 minutes for the count down cycle. The ON indicator will turn on, the
(E:1) programming. AM/PM indicators will turn off, the load will turn ON, and the time will start
6. Depress the UP or DOWN button and hold for 2 seconds, the time will decrementing at one (1) minute intervals. At the end of the count down
begin to scroll slowly in the direction you have selected. After 5 seconds, cycle, the load will turn OFF.
the time will scroll rapidly. There is an AM / PM indicator that will appear 3. The count down value can be changed at any time by pressing the UP or
to indicate a morning or evening setting. DOWN buttons. A maximum value of sixty (60) minutes or a minimum
7. Move the Mode slide switch to the VARI position and back to the value of one (1) minute can be set. The Delayed OFF can be stopped
MAN/PRGM (Manual / Program) position to program Event 2 (E:2). before the end of the cycle by moving the Rocker Switch to the other
Repeat steps 4 thru 6. position, or by moving the remote 3-way switch (if wired) to the other
8. Either Event is disabled when the TIME ON equals the TIME OFF. position.
9. Move the Mode slide switch to the VARI or AUTO RUN position to enable
the timer. Technical Specifications:

To program weekends different from weekdays: Model: LST700 / LST700+


1. Follow Steps 1 – 8 above to set all seven (7) days of the week the same. Supply: 110 - 125 VAC, 60 Hz, Neutral Line Required
2. Follow Steps 1 – 9 below to change Saturday and then Sunday (or any Load: 15 Amp Resistive, 5 Amp Inductive,
other days) differently. 625 Watts Incandescent, 1/2 HP Motors
Approvals: ▪ ETL CUS Listed, Conforms to UL STD 60730-1A & 60730-2-7.
To program individual days of the week: ▪ Certified to CAN/CSA E60730-1 & E730-2-7.
1. Move the Display slide switch to the Right position to TIME ON. ▪ Complies with FCC Part 15, Class B Requirements.
2. Move the Mode slide switch to the Left position to MAN/PRGM (Manual / ▪ Certified under Title 24, Part 6, Section 119(a), (b) & (c) of the
Program) position. The display will have a lowercase “d” and all Day of California Code of Regulations.
Week icons will blink. Surge Protection: Self-protecting against 1000V Transient Voltage Spikes
3. While the Day of Week icons are blinking, depress the UP or DOWN Storage Temperature: -4°F to +158°F (-20°C to +70°C )
button to scroll to the particular or next Day of Week to be programmed. Operating Temperature: +14°F to +131°F (-10°C to +5 5°C)
After 5 seconds, the timer will automatically enter Event 1 (E:1) program 5% - 95% Relative Humidity, Non-Condensing
mode. Memory Backup: Clock Time and Day of Week settings are protected against
4. Depress the UP or DOWN button and hold for 2 seconds, the time will power failure by internal battery backup. The screen is blank during a power
begin to scroll slowly in the direction you have selected. After 5 seconds, outage. Programmed Event Times are permanently stored in system memory. If
the time will scroll rapidly. There is an AM / PM indicator on the top right unit is in an Automatic Event Cycle during power outage, timer will automatically
of the display that will appear to indicate a morning or evening setting. resume ON or OFF settings without any required user interference.
5. Move the Display slide switch to the Left position to TIME OFF for Event 1
(E:1) programming. IMPORTANT NOTES:
6. Depress the UP or DOWN button and hold for 2 seconds, the time will
begin to scroll slowly in the direction you have selected. After 5 seconds, 1. Separate dimmers and photoelectric switches cannot be used in
the time will scroll rapidly. There is an AM / PM indicator that will appear combination with your timer.
to indicate a morning or evening setting. 2. It is recommended that your timer not be used with PAR or “R” type
7. Move the Mode slide switch to the VARI position and back to the outdoor flood lamps or lamps higher than 150 watts, since currents
MAN/PRGM (Manual / Program) position to program Event 2 (E:2). generated during lamp burn-out could damage the timer.
Repeat steps 4 thru 6.
8. Either Event is disabled when the TIME ON equals the TIME OFF. Warranty:
9. Move the Mode slide switch to the VARI or AUTO RUN position to enable
the timer. LIMITED ONE (1) YEAR LIMITED WARRANTY

Note: To disable either Event (E:1 or E:2), the Event TIME ON must be If within one (1) year from the date of purchase, this product fails due to a defect
programmed to equal to the Event TIME OFF. (example; E:2 ON @ 12:00am in material or workmanship, Swylite Corporation will repair or replace it, at its
and OFF @12:00am.) sole option, free of charge. This warranty is extended to the original household
purchaser only and is not transferable. This warranty does not apply to: (a)
Re-programming ON/OFF Events in your Timer: damage to units caused by accident, dropping or abuse in handling, acts of God
1. Move the Display slide switch to the Right position to TIME ON. or any negligent use; (b) units which have been subject to unauthorized repair,
2. Move the Mode slide switch to MAN/PRGM (Manual / Program) position. opened, taken apart or otherwise modified; (c) units not used in accordance with
The display will have a lowercase “d” and the current programmed Day of instructions; (d) damages exceeding the cost of the product; (e) sealed lamps
Week icon will blink and/or lamp bulbs, LED’s and batteries; (f) the finish on any portion of the
3. a) To reprogram all seven (7) days of the week the same; While the product, such as surface and/or weathering, as this is considered normal wear
Day of Week icon is blinking, depress the UP or DOWN button and scroll and tear; (g) transit damage, initial installation costs, removal costs or
left past Sunday or right past Saturday until all Days of the Week blink. reinstallation costs.
After 5 seconds, the timer will enter Event 1 (E:1) program mode.
4. b) To reprogram an individual day of the week; While the Day of Week SWYLITE CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL OR
icon is blinking, depress the UP or DOWN button to scroll to the particular CONSEQUENTIAL DAMAGES, SOME STATES DO NOT ALLOW THE
or next Day of Week to be programmed. After 5 seconds, the timer will EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
enter Event 1 (E:1) program mode. DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT
5. Depress the UP or DOWN button and hold for 2 seconds, the time will APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS
begin to scroll slowly in the direction you have selected. After 5 seconds, OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE
the time will scroll rapidly. There is an AM / PM indicator on the top right WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS
of the display that will appear to indicate a morning or evening setting. FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY
6. Move the Display slide switch to the Left position to TIME OFF for Event 1 AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE
(E:1) programming. SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME
7. Depress the UP or DOWN button and hold for 2 seconds, the time will STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN
begin to scroll slowly in the direction you have selected. After 5 seconds, IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO
the time will scroll rapidly. There is an AM / PM indicator that will appear YOU.
to indicate a morning or evening setting.
8. Move the Mode slide switch to the VARI position and back to the This warranty service is available by either (a) returning the product to the
MAN/PRGM (Manual / Program) position to program Event 2 (E:2). dealer from whom the unit was purchased, or (b) mailing the product, along with
Repeat steps 5 thru 7. proof of purchase, postage prepaid to the authorized service center listed
9. Either Event is disabled when the TIME ON equals the TIME OFF. below. This warranty is made by: Swylite Corporation, 1025 South Semoran
10. Move the Mode slide switch to the VARI or AUTO RUN position to enable Blvd., Suite 1093, Winter Park, Florida, 32792 / T: (407) 673-6544
the timer. http://www.Swylite.com

Once set up, the programmed times are stored in solid state memory and need Please be sure to wrap the product securely to avoid shipping and handling
never be programmed again unless desired or by a RESET. If you encounter a damage.
power failure the programmed event times will not be lost.
CALIFORNIA PERCHLORATE ADVISORY
To change the Current Day of Week: “Perchlorate Material – special handling may apply, See
1. Move the Display slide switch to the Right position to TIME ON. www.dtsc.ca.gov/hazardouswaste/perchlorate.”
2. Move the Mode slide switch to MAN/PRGM (Manual / Program) position.
3. Depress the UP or DOWN button and hold for 2 seconds, the ON/OFF
icons and all Day of Week (DOW) icons will blank. DO NOT CHANGE
THE CURRENT TIME UNLESS DESIRED. After 5 seconds, the Clock
Time will disappear and the current Day of the Week will blink. Depress
the UP or DOWN button to scroll left or right to change the Current Day of
the Week to the desired setting. Swylite Corporation
1025 S. Semoran Blvd, Suite 1093
Operation of Manual Delayed OFF Mode: Winter Park, FL 32792 USA
http://www.Swylite.com
Questions/Problems? 1-877-673-6544 Doc. No. 7000-0024, Rev. B