DIAGRAMA DEL POZO Elaborado por: SUPERVISOR DE POZO
Revisado por: ING. DE OPERACIONES
Aprobado por: SUPERINTENDENTE DE OPERACIONES
EQUIPO FECHA SISTEMA AUTOR CODIGO
FAST DRILLING 11 27-sep-17 EQUIPO BES ING. PATRICIO QUILLUPANGUI 4458

DRAGO NORTE - 03 D
W.O # 03 CABEZAL MISSION PETROLEUM 11" x 3 1/8" x5M
C & PI: 13-abr-11
R.T.E. = 918.44' W.O # 01: 16-jun-12
G.L.E. = 882.00' 11"x 3-1/2"x 5M PSI TBG HANGER W.O # 02: 27-ago-17
E.M.R. = 36.44' SINOPEC-169 W.O # 03: 27-sep-17

227' 20" CASING CONDUCTOR K-55, 94 LBS/P.


ZAPATO GUIA
CEMENTADOS CON 566 Sxs. TIPO "A"
PESO DE LA SARTA
SUBIENDO = 130 KLBS
BAJANDO = 108 KLBS

MAXIMA INCLINACION: 30.87° @ 2482' MD


13 3/8" CASING SUPERFICIAL C-95, 72 L/P BTC, 146 JTS

3-1/2" EUE BOX X 3-1/2" SEC PIN X-OVER

13 3/8" ZAPATO GUIA SUPERFICIAL CEMENTADO CON:


6034' 2342 SKS "A" + TOP JOB CON 140 SKS "A"

9 5/8" CASING INTERMEDIO, C-95, 47 LB/P 211 JTS


Material Usado
Quick Conector P3002
(316) Protectores cannon=(218) 3500 A-76 Y (98) 3500 A-65 3 1/2" EUE, 64 TUBOS CLASE "B", L-80, 9.3 LB/FT
(320) Mid Joint 3500C-76 (RECUPERADA POZOS DRRA-028 Y DRRA-006)
Total Bandas 58 = 29 en equipo, 10 en BHA y 19 en tbg 3 1/2" SEC, 133 TUBOS CLASE "B" L-80, 9.2 LB/FT
Existe empate de cable @ +-4350 ft y 8600 ft. (RECUPERADA POZOS SHS-185, DRRD-30, SHS-179, SHS-139)
Tbg Hanger inspecionado y/o reparado al 26-sep-17 3 1/2" SEC, 121 TUBOS CLASE "B" TN-70, 9.2 LB/FT
(100) ft de cable MLE (RECUPERADA POZOS SHS-185, DRRD-30, SHS-179, SHS-139)
Equipo de Fondo en calida de renta TOTAL 318 TUBOS DE 3 1/2"
9917' ft de Cable propiedad de PAM EP
9024' 7" COLGADOR DE LINER

9208' 9-5/8" ZAPATO GUIA CEMENTADO CON 1070 SKS "G"


3-1/2" EUE PIN X 3-1/2" SEC BOX X-OVER
9871' 3-1/2" EUE CAMISA (SPP-3599)
3-1/2" EUE (1) TUBO 9.3 L/P, N-80 CLASE "B"

9904' 3-1/2" EUE NO-GO (NRC-401-17) (W/STV VAC-0025)

3-1/2" EUE (1) TUBO 9.3 L/P, N-80 CLASE "B"


9937' 3-1/2'' DESCARGA DE CABEZA SERIE 400 P/N 364240
DESCARGA DE PRESION PHOENIX SERIE 400 P/N 100144521
9938' BOMBA SUP D1050N 126 STAGES SERIE 400
9960' BOMBA INTERM. D1750N 102 STAGES SERIE 400

9979' BOMBA INF. D1750N 102 STAGES SERIE 400


9998' INTAKE / SEPARADOR DE GAS SERIE 400 P/N 101930575
PROTECTOR SUP. BPBSL-UT, INC, RLOY, MAX SERIE 400
10017'
PROTECTORE INF. BPBSL-LT, INC, RLOY, MAX SERIE 400
10017' MOTOR SERIE 456 P/N 101901366 120 - 1508 VOLT - 52,0 AMP
SENSOR SERIE 450 PHOENIX XT150 TYPE 1
ARENA "U inf" (Fracturada WO#03) CENTRALIZADOR 5-1/2"
10043'
10122´-10130´(8´) @ 5 DPP
10130'-10137' (7') @ 15 DPP Rep. WO#03
10137'-10140' (3') @ 10 DPP Rep. WO#03 7" LINER, C-95, 26 Lbs/P, BTC, R-3, 38 Tubos.
10140' - 10147' (7') @ 5 DPP Rep. WO#03
10275' 7" EZ-DRILL (WO-03)

10300' 7" EZ-DRILL (WO-02)


ARENA "T inf" (TCP)
10357'- 10366' (9') @ 6 DPP

10450' 7" CIBP

ARENA "H sup"


10499'- 10510' (11') @ 5 DPP
10589' 7" COLLAR FLOTADOR
10681' PT (D) = 10681' MD 7" ZAPATO GUIA CEMENTADO CON 400 SXS TIPO "G"
PT (LOG) =10692' MD