The Institution of Engineers, Malaysia (Sabah Branch)

Lot 25, 3rd Floor, Block C, Damai Point Commercial Centre, Lorong Damai Point, JalanDamai, 88300
Luyang, Kota Kinabalu, Sabah Tel: 088-259122 (2 lines) Fax : 088-236749 E-mail : iemsabah@gmail.com

One Day Seminar on


“Automatic Transfer Switch based on MS IEC 60947 (6-1) &
Power Capacitors based on MS IEC 60831 (1-2)”

Date : 26 April 2018 (Thursday) BEM Approved


Time : 8:30am– 5:00pm CPD HOURS: 6
Venue : IEM Sabah Training Centre, Lot 25-3, Damai Point Commercial Centre, Jalan Damai, IEMSABAH/2018/09
Luyang, Kota Kinabalu

Registration Fees (per person)


Membership Grade Registration fee
(incl. 6% GST)
IEM Member RM 120.00
Non Member RM 180.00

**Notes:
GST per pax: RM6.79 (Member) / RM10.19 (Non-Member)
Please register early. Participant must fulfill at least 75% of attendance per event to be eligible for CPD certificate.

TOPICS
1) MS IEC60947-6-1 for ATSE
• Short circuit withstand of ATS
• Category utilization - AC31/33 in "A" or "B"
• Different Class of ATSs' - CB, PC & CC
• Standard Transfer : Open Type - Simple transfer system for small load
• Closed Transition Transfer : Overlap Type - For uninterruption of power supply to load

2) The functionality and application for different types of Automatic Transfer Switch. Types of Automatic Transfer Switches
available for different application such as :-
• Delay Transfer with “OFF” position : Open Type - The “OFF” position is important when transferring large motor load.
This is to allow the magnetic field to “decay” before transfer to prevent back EMF generated by the motor which can trip
the CB or blow the fuses.
• High Speed Transfer less than 20ms : Open Type - Introducing High speed transfer for loads such as electronic
equipment without interruption. Comply to SEMI-F47, ITIC – Voltage / depth duration curve.

3) As required in MS IEC, together with the Smart ATS Controller, these Automatic Transfer Switches function perfectly without
much complications. The ATS Smart controller had functions for voltage, frequency and timer settings for types for
application. Engine start / stop and other functions are also available from these Smart Controllers

4) Comparison to other types of change-over devices as ATS.

SPEAKERS
MR S.F. NG is currently the sales and marketing engineer at Wisepro Sdn Bhd. He has been working in the industry for the past
10 years and has gathered great experience in the design, installation, troubleshooting and site works for the industries mentioned
above. He has also received extensive training on the Lightning Protection at Dehn headquarters in Germany, power factor
capacitors, reactors and harmonics at Shizuki headquarters in Japan and ATS applications and troubleshooting at Vitzrotech
headquarters in Korea. He graduated from the University of Hertfordshire with a Master’s Degree in Automotive Engineering.

MR RITESH LUTCHMAN is currently the Senior Sales and Marketing Manager at Wisepro Sdn Bhd. He has been working in the
industry for the past 15 years and has gathered great experience in the design, installation, troubleshooting and site works for the
industries mentioned above. He has also received extensive training on the Lightning Protection at Dehn headquarters in
Germany, power factor capacitors, reactors and harmonics at Shizuki headquarters in Japan and ATS applications and
troubleshooting at Vitzrotech headquarters in Korea. He graduated from the University of Cape Town with a Master’s Degree in
Electrical Engineering.

CONTINUE NEXT PAGE….


TENTATIVE PROGRAMME
08:30am – 09:00am Registration
09:00am – 10:30am Standards governing ATS and ATS Controllers
Transfer Switch technologies and comparisons
Redundancy, Resilience and Reliability of ATS Mechanical
Electrical Characteristics of ATS
10:30am - 11 00am Tea Break
11:00am - 12 30pm Utilization category (ATS sizing)
ATS Protection (Fault Free Zone)
ATS Controller characteristics
Various ATS types and description (Open Transition, Closed Transition, High Speed etc)
12:30pm – 01:30pm Lunch
01:30pm – 03:00pm Standards governing power capacitors
Destruction test
Ageing test
Self healing test
Power Capacitor Design
Power Factor Controller
03:00pm – 03:30pm Tea Break
03:30pm – 05:00pm Use of reactors and design consideration for detuned filters
Selection guide for reactors
Design of capacitor banks for PF correction, Transformer and motors
Guidelines for installation of capacitor banks and reac-tors.
05:00 Q&A, End

-----------------------------------------------------------------------------------------------------------------------------------------
REGISTRATION FORM

One Day Seminar on


“Automatic Transfer Switch based on MS IEC 60947 (6-1) & Power Capacitors based on MS IEC 60831 (1-2)”

I/We wish to participate in the above seminar on Thursday, 26 April 2018 (8.30am – 05.00pm)
Name (s) BEM No. IEM No. Reg. Fees (RM)

Total RM

Contact Person : ……………………….………………………. Designation : …….………………..……….…

Address : ……………………….………………………. Tel No. : …….………………..……….…

………..……………………………………… Fax No. : …….………………..……….…

……….…………………………………….… Email : …………………………………………

Organization : ……….…………………………………….…

……………………………………………. …………………………………………….
(Date) (Signature)
- Please bring along this flyer for confirmation of attendance -

-Photostat copies are acceptable –


I/We understand that the fee is not refundable if I/we withdraw after my/our application(s) is/are accepted by the IEM Sabah. However,
substitution of participants will be allowed. If I/we fail to attend the seminar, I/we will still settle the registration fee in full.

Payment details: The Institution of Engineers Malaysia : 60098-00100-11240 (Alliance Bank)