Harmonic Analysis

Perform frequency scan, and voltage and current


distortion calculations on balanced and unbalanced
systems
The number of electronic The Harmonic Analysis module to utility-type grids, industrial The Frequency scan capability
is an indispensable tool to power systems and distribution included in this module is also
devices and other non-linear help engineers evaluate the feeders of any configuration. It available as an independent
loads that are connected to harmonic level of their electrical utilizes state-of-the-art sparse module. This analysis provides
the power system generate network and to assess different matrix/vector methods with a full impedance scan results
mitigation methods. three-phase nodal admittance and allows the user to see
harmonics which affect the network matrix representation. problematic areas even before
It features a number of analyses
quality of the power to the such as frequency scan,
The Harmonic Analysis module installing harmonic devices.
end customers. Capacitors, uses the CYME robust load
voltage and current distortion
flow algorithm to obtain the
which are installed to calculations, capacitor rating and
fundamental frequency current
filter sizing analysis, and K-Factor
improve the system voltage and Factor-K calculations. The
and voltage system profile for
harmonic distortion calculations
and reduce losses, can create module allows the user to
and waveform display.
resonance if their location is model non-linear loads and
other sources of harmonic
not optimal. Such harmonic currents such as converters
distortions, if un-mitigated, and arc furnaces and toeasily
detect resonant frequencies
have a detrimental effect due to capacitor banks. With its
on the power quality as many modeling and analytical
they can cause equipment capabilities, the Harmonic
Analysis module makes it
malfunction, overheating possible to accurately evaluate
of equipment and increase the impact of non-linear loads on
power losses. the electrical network.
The module features both
single phase and full three-
phase modeling capabilities,
with the flexibility to make
the program easily adaptable
Harmonic Analytical Capabilities
• Phase or sequence analysis
Capacitor Stress and Filter
Sizing
Equipment Library
Users can model multiple types
The Harmonic Analysis module of harmonic sources to assess
Analysis • Driving point and transfer
point frequency scan analysis
features stress analysis of
capacitors, including those
the effectiveness of filters and
modify them at will in order
• Harmonic voltage distortion incorporated in filters, to help to attain acceptable level of
analysis engineers determine whether harmonic distortion indices on
the capacitors are rated properly your network.
Perform frequency scan, • Harmonic current distortion according to user-defined or
analysis Our extensive library includes
and voltage and current IEEE standard limits.
equipment such as:
• Calculation of telephonic
distortion calculations on interference indices (TIF, IT,
Likewise, fundamental resistor • Ideal and non-ideal converters
losses, fundamental and
balanced and unbalanced etc.) harmonic current through the • Generic single or multiple
systems. • Evaluate system sensitivity reactance, and fundamental and frequency current and voltage
level harmonic voltage through the source models. This includes
capacitor of filters are calculated a library of drives with typical
• Harmonic cancellation to help engineers determine if harmonic spectrum as per
• System detuning via filter the filters are sized properly. IEEE 519.18™
sizing • Arc furnace model
Transformer K-Factor
• Capacitor stress analysis Calculation • Passive shunt filter models
• Skin effect modeling The Harmonic Analysis module comprising single tuned, high-
also offers the Transformer pass, double tuned and C-type
• User defined distortion limits
or as per IEEE 519™ 1992 K-Factor (ANSI/IEC) and • Library of single phase and
standard Factor-K (BS) calculation for three-phase transmission line
the assessment of transformer and cable models, series R-L,
• Selection of line/cable models: rating with respect to the nominal Pl and distributed
series R-L, nominal Pl, harmonic level of the system. parameters
transposed and un-transposed
distributed parameters, and • Synchronous and induction
frequency-dependent motor models
• Selection of load models: • Single phase and three-phase
(Parallel R-L, Series R-L, transformer models allowing
CIGRE C-Type, etc.) harmonic cancellation through
their phase shift angles
• Modeling harmonic sources
of nonlinear loads and power
electronics equipment
• Static load modeling: parallel
R-L and CIGRE C-Type
• Series and parallel RLC
branch circuits to create any
user defined equipment

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

CYME International T&D


1485 Roberval, Suite 104
St.Bruno, QC, Canada J3V 3P8
P: 450.461.3655 F: 450.461.0966
P: 800.361.3627 (Canada/USA)
CymeInfo@eaton.com
www.eaton.com/cyme
Follow us on social media to get the
© 2015 Eaton All Rights Reserved Eaton is a registered trademark. latest product and support information.
Printed in Canada
Publication No. BR 917 011 EN All other trademarks are property
November 2014 of their respective owners.