CONNECTION GUIDE

IV-H Series

SIEMENS
S7-1200 Series
PLEASE PREPARE
Please prepare the following products.

Vision Sensor Power IO cable Ethernet cable


CPU module
IV-H Series OP-87440 (2 m) OP-87457 (2 m)

SIEMENS
S7-1200 Series

CONNECTING
Below would be the way how to connect IV to your PLC.

Ethernet hub

SIEMENS
S7-1200 Series
IV-H Series

Ethernet cable SIGNAL COLOR


OP-87457
24V Brown
24VDV Power supply
0V Blue

PROFINET is a trademark or a registered trademark of PROFIBUS & PROFINET International.


Other proper nouns such as product names included in this manual are trademarks or registered trademarks of their respective companies.

2
SETTINGS [IV-H Series]
Use IV-Navigator for settings.

Use the Ethernet cable OP-87457 to connect Select “Advanced”  “Environmental”, and confirm
1 IV to your PC 4 what the “Device Name” is set to.

IV-H Series PC (IV-Navigator installed)

Ethernet Cable OP-87457

2 Start IV-Navigator
Select “Advanced”  “Environmental”  “Field
Double click the icon of IV-Navigator 5 Network”, and set the “Protocol” to “PROFINET”
on your desktop.

3 Select “Network Connection” and connect to IV-H

Please be sure that your PC’s IP address is fixed, and the IP


address of IV-H is initialized (“----”).
Please refer to the Users Manual for the way how to initialize
the IP address.

3
BASIC SETTINGS [SIEMENS S7-1200 SERIES]
TIA Portal V.11 or later would be required to communicate PROFINET.

Double click “Add new device” under the new project


1 Start TIA Portal 4 that has been added to the “Project tree”

Double click the icon of TIA Portal On the “Add new device” screen, click the S7-1200 Series you
on your desktop. are using, and then click “OK”.

Click “Project View” which is in the lower left of the


2 screen

Open the “Online access” which is inside the “Project


5 tree”, and then select the network card your S7-1200
is connected.

Double click “Update accessible devices”. The S7-1200


which is connected would appear.
Click the “new project” icon, and open the “Create a Open the appeared S7-1200, and then double click “Online &
3 new project” screen diagnostics”.

Input a project name, and then click “Create”.

4
BASIC SETTINGS [SIEMENS S7-1200 SERIES]

Click “Assign IP address” which is under “Functions”, Click “Project View” which is in the lower left of the
6 set the IP address and the subnet mask of the 8 screen, and then click “Open” on the “Project” menu
S7-1200, and then click “Assign IP address”

Select a project, and then


If the PLC already has one IP address set, you may not be
click “Open”.
able to set a new IP address. At this case, click “Reset to
The “Open existing
factory settings”, and initialize the IP address once.
project” screen would be
displayed, click a project
and then click “Open”.
Double click "Devices &
networks".

In the “Hardware catalog” field, click “Other field


devices”  “PROFINET IO”  “Sensors” 
9 “KEYENCE CORPORATION”  “Keyence Vision
Sensors”

Confirm that the IV Series


Register the GSDML file. Open the “Options” menu, could be selected.
7 and click “Install general station description file
(GSD)”

Specify the folder which has the GSDML file inside, select the
check box of the target GSDML file, and click “Install”.
After the install is finished, TIA Portal would restart.

5
BASIC SETTINGS [SIEMENS S7-1200 SERIES]

In the “Devices & networks” field, click the “Network On the “Network view” tab, double click the
10 view” tab, and drag the “IV” to this tab
12 image of IV
In the “Device overview” window of the “Device view” tab,
enter into the top of the table the Profinet device name of your
IV.

Click the green box which is close to the “IV” to create


11 a line, and extend it to the green box close to the
“PLC”.

Your IV would be connected to S7-1200.

Double click the image of IV, click the “General” tab,


13 click “PROFINET interface”, click “Ethernet
addresses”, and then set the IP address of IV

If the IP address which is already set to IV was different


from the one which you set here, the IP address would be
overwritten to this.

Double click the image of IV, click the “General” tab,


14 click “PROFINET interface”, click “Advanced options”,
click “IO cycle”, and then set the “Update time”

6
BASIC SETTINGS [SIEMENS S7-1200 SERIES]

On the “Network view” tab, double click the image of On the “Extended download to device” screen, select
15 the PLC 18 the interface connected to the PLC, select the target
PLC, and then click “Load”
On the “General” tab, click “Profinet interface”, click “Ethernet
addresses”, and then set the IP address of the PLC. If “Different modules”, “No action” is displayed on the “Load
preview” screen, select “Accept all”, and then click “Load”.
After the “Load results” screen is displayed, click “Finish”.

Click the “Network view” tab, right click the image of


16 the PLC, point to “Compile”, and then click “All”

Right click the image of the PLC, point to “Download


17 to device”, and then click “All” to transfer the settings
to S7-1200

7
MONITORING THE RESULT

Check the address of the PLC device assigned


1 to IV
3 Switch to online mode and start monitoring.

On the “Network view” tab, click IV, and click the “Device
Click “Go online”
view” tab.
to switch to online
mode. On the “Online
menu”, click “Monitor
all”.

The addresses are assigned to each module automatically.


(These could be assigned manually also)
4 Click “RUN” on the CPU operator panel.

You could see the result in the “Monitor value”.

Click “Watch and force tables”, and then double click


2 “Add new table”.

In Watch table, enter


the address which is
assigned. In the “Address”, please input “IW” if the data type was
“WORD”. Please input "IB" if the necessary information was a
"BIT data".If the result for Tool Result_1 was necessary, please
input "%IW276"

8
www.keyence.com

Copyright (c) 2016 KEYENCE CORPORATION. All rights reserved. IVHS7-1200ConnectionG-WW-OT-GB 1037-2 600J17