IV-H Series
SIEMENS
S7-1200 Series
PLEASE PREPARE
Please prepare the following products.
SIEMENS
S7-1200 Series
CONNECTING
Below would be the way how to connect IV to your PLC.
Ethernet hub
SIEMENS
S7-1200 Series
IV-H Series
2
SETTINGS [IV-H Series]
Use IV-Navigator for settings.
Use the Ethernet cable OP-87457 to connect Select “Advanced” “Environmental”, and confirm
1 IV to your PC 4 what the “Device Name” is set to.
2 Start IV-Navigator
Select “Advanced” “Environmental” “Field
Double click the icon of IV-Navigator 5 Network”, and set the “Protocol” to “PROFINET”
on your desktop.
3
BASIC SETTINGS [SIEMENS S7-1200 SERIES]
TIA Portal V.11 or later would be required to communicate PROFINET.
Double click the icon of TIA Portal On the “Add new device” screen, click the S7-1200 Series you
on your desktop. are using, and then click “OK”.
4
BASIC SETTINGS [SIEMENS S7-1200 SERIES]
Click “Assign IP address” which is under “Functions”, Click “Project View” which is in the lower left of the
6 set the IP address and the subnet mask of the 8 screen, and then click “Open” on the “Project” menu
S7-1200, and then click “Assign IP address”
Specify the folder which has the GSDML file inside, select the
check box of the target GSDML file, and click “Install”.
After the install is finished, TIA Portal would restart.
5
BASIC SETTINGS [SIEMENS S7-1200 SERIES]
In the “Devices & networks” field, click the “Network On the “Network view” tab, double click the
10 view” tab, and drag the “IV” to this tab
12 image of IV
In the “Device overview” window of the “Device view” tab,
enter into the top of the table the Profinet device name of your
IV.
6
BASIC SETTINGS [SIEMENS S7-1200 SERIES]
On the “Network view” tab, double click the image of On the “Extended download to device” screen, select
15 the PLC 18 the interface connected to the PLC, select the target
PLC, and then click “Load”
On the “General” tab, click “Profinet interface”, click “Ethernet
addresses”, and then set the IP address of the PLC. If “Different modules”, “No action” is displayed on the “Load
preview” screen, select “Accept all”, and then click “Load”.
After the “Load results” screen is displayed, click “Finish”.
7
MONITORING THE RESULT
On the “Network view” tab, click IV, and click the “Device
Click “Go online”
view” tab.
to switch to online
mode. On the “Online
menu”, click “Monitor
all”.
8
www.keyence.com
Copyright (c) 2016 KEYENCE CORPORATION. All rights reserved. IVHS7-1200ConnectionG-WW-OT-GB 1037-2 600J17