CONNECTION GUIDE

IV-H Series

SIEMENS
S7-1500 Series
PLEASE PREPARE
Please prepare the following products.

Contact probe Power IO cable Ethernet cable


CPU module Ethernet cable / hub
IV-H Series OP-87440 (2m) OP-87457(2m)

SIEMENS
S7-1500 Series

CONNECTING
Below would be the way how to connect the IV-H series to your PLC.

IV-H Series Ethernet hub

SIEMENS
S7-1500 Series
Ethernet cable
OP-87457

Signal Color

24V Brown
24VDV Power supply
0V Blue

PROFINET is a trademark or a registered trademark of PROFIBUS & PROFINET International.


Other proper nouns such as product names included in this manual are trademarks or registered trademarks of their respective companies.

2
SETTINGS [IV-H Series]
Use IV-Navigator for settings.

Use the Ethernet cable OP-87457 to connect Select “Advanced” " “Environmental”, and confirm
1 IV to your PC 4 what the “Device Name” is set to.

IV-H Series PC (IV-Navigator installed)

Ethernet Cable OP-87457

2 Start IV-Navigator
Select “Advanced” " “Environmental” " “Field
Double click the icon of IV-Navigator 5 Network”, and set the “Protocol” to “PROFINET”
on your desktop.

3 Select “Network Connection” and connect to IV-H

Please be sure that your PC’s IP address is fixed, and the IP


address of IV-H is initialized (“----”).
Please refer to the Users Manual for the way how to initialize
the IP address.

3
BASIC SETTINGS [SIEMENS S7-1500 SERIES]
TIA Portal V.13 or later would be required to communicate PROFINET.

Double click “Add new device” under the new project


1 Start TIA Portal 4 that has been added to the “Project tree”.

Double click the icon of TIA Portal On the “Add new device” screen, click the S7-1500 Series you
on your desktop. are using, and then click “OK”.

Click “Project View” which is in the lower left of the


2 screen.

Open the “Online access” which is inside the “Project


5 tree”, and then select the network card your S7-1500
is connected.

Double click “Update accessible devices”. The S7-1500


which is connected would appear.
Open the appeared S7-1500, and then double click "Online
& diagnostics".

Click the “new project” icon, and open the “Create a


3 new project” screen.

Input a project name, and then click “Create”.

4
BASIC SETTINGS [SIEMENS S7-1500 SERIES]

Click “Assign IP address” which is under “Functions”, Click “Project View” which is in the lower left of the
6 set the IP address and the subnet mask of 8 screen, and then click “Open” on the “Project” menu.
the S7-1500, and then click “Assign IP address”.

If the PLC already has one IP address set, you may not be Select a project, and then
able to set a new IP address. click “Open”.
At this case, click “Reset to factory settings”, and initialize the The “Open existing
IP address once. project” screen would be
displayed, click a project
and then click “Open”.
Double click “Devices &
networks”.

In the “Hardware catalog” field, click “Other field


devices” " “PROFINET IO” " “Sensors” "
9 “KEYENCE CORPORATION” " “Keyence Vision
Sensors”.

Confirm that the IV Series


Register the GSDML file. Open the “Options” menu, could be selected.
7 and click “Install general station description file
(GSD)”.

Specify the folder which has the GSDML file inside, select the
check box of the target GSDML file, and click “Install”.

5
BASIC SETTINGS [SIEMENS S7-1500 SERIES]

In the “Devices & networks” field, click the “Network Double click the image of IV-H, click the “General” tab,
10 view” tab, and drag “IV-HG Main Unit” to this tab. 13 click “PROFINET interface”, click “Ethernet
addresses”, and then set the IP address of IV-H.
Please drag the correct IV series you are using.
If the IP address which is already set to IV-H was different
from the one which you set here, the IP address would be
overwritten to this.

Click the green box which is close to “IV-H” to create


11 a line, and extend it to the green box close to the
“PLC”.

Your IV-H would be connected to S7-1500.


Double click the image of IV-H, click the “General” tab,
14 click “PROFINET interface”, click “Advanced options”,
click “IO cycle”, and then set the “Update time”.

On the “Network view” tab, double click the


12 image of IV-H.
In the “Device overview” window of the “Device view” tab,
enter into the top of the table the Profinet device name of your
IV-H.

6
BASIC SETTINGS [SIEMENS S7-1500 SERIES]

Click the “Network view” tab, right click the image of On the “Extended download to device” screen, select
15 the PLC, point to “Compile”, and then click “Hardware 17 the interface connected to the PLC, select the target
and software (only changes)”. PLC, and then click “Load”.

If “Different modules”, “No action” is displayed on the “Load


preview” screen, select “Accept all” or “Download to device”
or “Consistent download”, and then click “Load”.
After the “Load results” screen is displayed, click “Finish”.

Right click the image of the PLC, point to “Download


16 to device”, and then click “Hardware and software
(only changes)” to transfer the settings to S7-1500.

7
MONITORING THE RESULT

1 Check the address of the PLC device assigned to IV-H 3 Switch to online mode and start monitoring.

On the “Network view” tab, click IV-H, and click the “Device Click “Go online” to switch to online mode.
view” tab.

Click the “Monitor” icon, and click “RUN” on the CPU


4 operator panel.

The addresses are assigned to each module automatically. You could see the result in the “Monitor value”.
(These could be assigned manually also)

Q address : Output address (PLC " IV-H)


I address : Input address (PLC ¥ IV-H)

Click “Watch and force tables”, and then double click


2 “Add new table”. In the “Address”,
please input “IW” if the data type was “WORD”.
In Watch table, enter please input “ID” if the data type was “DWORD”.
the address which is please input “IB” if the necessary information was a “BIT data”.
assigned. If the Tool result 1 was necessary for this sample, please input
“%IW320”

8
www.keyence.com