Sunteți pe pagina 1din 194

Installation

Systems
Catalogue

Value-adding system solutions.

Hilti. Outperform. Outlast.


PC Software

Hilti. Around the world support.

The Hilti Group is a world leader in developing, manufacturing and mar-


keting added-value, top-quality products for professional customers in
the construction industry and in building maintenance.
Our product range covers drilling and demolition, direct fastening, diamond
and anchoring systems, firestop and foam systems, installation, measuring
and screw fastening systems as well as cutting and sanding systems. We are
committed to excellence in innovation, total quality, direct customer relation-
ships and effective marketing.

Hilti operates in over 120 countries around the world.


Of our more than 20,000 employees, two-third work directly for our cus-
tomers, in sales organizations, engineering and customer service. We have
production plans and research and development centers in Europe and Asia.
Our corporate headquarters is located at Schaan in the Principality of Liech-
tenstein.
Founded in 1941, the worldwide Hilti Group evolved from a small family
company. The Martin Hilti Family Trust holds all of the registered shares and,
after going private in 2003, about 99 percent of the non-voting participation
certificates of Hilti Corporation. The intention of the Martin Hilti Family Trust is
to safeguard our founder Martin Hilti’s life’s work in the long term.

Hilti’s corporate policy aims to build stakeholder value.


Only by integrating the interests of all the company’s partners, at home and
abroad – employees, customers, suppliers, local communities and authorities
as well as the financial community – can we create the foundation of confi-
dence on which Hilti builds its long-term success.ers, local communities and
authorities as well as the financial community – can we create the foundation
of confidence on which Hilti builds its long-term success.

Hilti Systems & Solutions

Applica- Planning & Measuring Drilling & Cutting & Fastening & Insulation & Professional &
tion Specifying Demolition Grinding Installation Protection Services

Specification Distance Drilling & Cutting Direct Foam Systems Repair Service
Consulting Measuring Chiseling Sanding Fastening Fire Stopping Lifetime Service
Engineering Leveling & Diamond Diamond Screw
Software Aligning Systems Systems Fastening
Sensing Anchoring
Installation

We are committed to excellence in innovation, total quality, direct customer relationships and effective marketing.
Contents

Description Pages

Services and PC Software 4-8

Technical Information 13 - 24

System MM Light and Medium Duty Channel Galvanized 28 - 39

System MQ Medium Duty Channel Galvanized 44 - 72

Galvanized Pipe Rings 76 - 92

System MQ Channel Installation Hot Dipped Galvanized 92 - 122

System MQ Channel Installation Stainless Steel 126 - 142

System MI Industrial Pipe and Electrical Supports 146 - 168

Fixed Points and Sliders 172 - 177

System MQ Air-conditioning and Ventilation 182 - 188

Firestop Systems 190 - 193

page 3
PC Software

Professional assistance.
and Technical
PC Software

Helps make every project a success.


Information
Medium duty

System MM
Light duty
Medium duty
System MQ
Hilti Pipe Rings

Engineering design and calculation


When you need support in identifying the most suitable, cost-effective and approved solution from Hilti for your different fasten-
ing, firestopping or installation tasks, our Engineering team will be at your side free of charge.

Technical seminars
Medium duty
System MQ

We offer technical seminars regarding Hilti engineered products free of charge, covering various topics ranging from the princi-
HDG

ples behind these products to the most commonly used international norms and standards.

Material estimation
For all the firestopping applications at site, we provide you free of charge material estimations for the most cost-effective, tested
Stainless Steel

and approved system, based on the firestop estimation form filled by you.
Medium duty
System MQ

Hands-on training and mock-up


To ensure a proper application of our firestop and installation systems products, hands-on training will be provided free of
charge for all installers. On top, mock-ups will be done free of charge to verify if the recommended solution suits the actual con-
ditions.
System MI

UL and BS based engineering judgement


HDG

Engineering judgements will be provided free of charge by certified Hilti Fire Protection Engineers. These judgements represent
firestop systems that would be expected to pass the stated ratings and requirements if tested, for those situations where a
tested system is not doable at site.
Fixed points
System MQ
and sliders

Pullout test
We will provide pullout testing free of charge. A qualified Hilti representative will check on site if the trained workers already know
how to properly install anchors and/or verify the loads in case of uncertain base material strength. Number of free pullout tests
will be provided as per the Hilti policy.
Airconditioning
and Ventilation

Random spot inspection


System MQ

To assist the customer in verifying proper installation according to the approved firestop systems and to facilitate the require-
ments of the project’s official firestop inspectors, a qualified Hilti representative will do random spot inspections on site free of
charge.

Project tendering, planning and support


Firestop systems

Our experienced technical staff give you support to ensure things are done right first time. We can help with bidding, norm and
non-norm specification and provide individual type catalogues. Plans, materials lists, calculations and drawings for larger pro-
jects are part of the package. Hilti project managers assist by coordinating logistics services and technical support for defined
projects.

page 4
PC Software

PROFIS Installation
Profis Installation is a Hilti PC applications for the static design of 3D structures
assembled from Hilti channel installation system components. It is suitable for use
with Microsoft Windows®.

Features and Functions


- Design and static calculation of 3D support structures for pipes, cable trays and
ventilation ducts
- Design of structures to be fastened to concrete or to steel beams
- Graphical presentation of 3D structures on the PC screen
- 3D structures can be exported to PDS and PDMS as well as other CAD programs
- Calculations for the static verification of structures with detailed report:
• Drawing (3D model) of the structure
• The applicable data
• Comments
• Calculation results
• Parts lists

Working with PROFIS


Installation
The data can be entered by the following means:
- Using the buttons on the screen and/or
- Clicking on the corresponding component or dimension and/or
- Entering the data in the design data table

Features and Functions


3D design window:
• The 3D view of the structure can be zoomed and shifted using the mouse or
program buttons
• The button at the edge of the design window can be used to create a 3D structure

Left side of screen:


• Project Explorer showing structure of the project
• Creation of instullation sub-project
• Creation of parts lists
• As an alternative to the design window, models can also be created or modified
by entering data in the table

page 5
PC Software

Hilti support solution


and Technical
PC Software
Information

for industry
Hilti as supplier and partner for industry with his successful
assembly systems MI and MQ knows the importance of
software in the planning process. In assistance of this process
Medium duty

System MM
Light duty

Hilti offers libraries and/or special tools for the most important
plant design software. These libraries and tools assist the
designer to use the Hilti assembly systems in the same way like
pipe parts or welded steel construction. This means placing
parts in the standard software program including automatically
generating drawings and bill of material.
Medium duty
System MQ
Hilti Pipe Rings

Features and functions


– 3D PDS environment of use for design of pipe supports
– Hilti system MI and MQ product portfolio available
Medium duty

– Quick selection and placement, including automatically


System MQ

adjustment of connectors and cutting of channels


HDG

– Logical linking between pipe and pipe support


– Automatically generated drawings in three views and the
perspective, including pipe name, BOM, dimension and
situation plan from the 3D model
Stainless Steel
Medium duty
System MQ

– Detailed BOM generated automatically, including item


number, lengths and weights
– Transmission of pipe supports to the 3D PDS model
– Full integration to PDS data base
System MI
HDG
Fixed points
System MQ
and sliders

Features and functions


– Easy and quick steel construction software
– Simple application for smaller project in 3D plant design
Airconditioning
and Ventilation

– Data base with several steel profiles


System MQ

– Data base with MI girder and MI components


– Logical supported connection between components and
girder/steel beams including automatically cutting of girder
– Bill of material from the 3D model
– Derive of 2D fabrication drawings from the 3D model
Firestop systems

– Drawings with position numbers and weights

page 6
PC Software

The world’s most powerful


anchor design software

Hilti PROFIS Anchor


The freedom to design faster - with confidence!

Hilti PROFIS Anchor is the most comprehensive anchor


design program available. It’s a 3D anchor design world
on your desktop and a database packed with Hilti
anchoring expertise.

Easy to learn
Start working in just minutes with the user-
friendly interface.

Fast and powerful


Produce detailed designs quickly in a few
simple stages: You choose the level of
complexity involved.

For reliable specifications


Specify in confidence with the largest number
of international approvals and test reports at
your fingertips, and stay up to date with regular
downloads.

PROFIS Anchor is available free of


charge. Download it at
www.hilti.xx, or order it on CD ROM.

Exclusive features:
n Comprehensive, easy-to-use anchor selector feature
n Database of exportable CAD drawings for all Hilti anchors via drag-and-drop menu
n Baseplate shaping in 3D modeling using finite element analysis for baseplate thickness
calculation
n Free anchor location in 2D/3D modeling application
n Save personalized user preferences

Other major features:


n Level of program detail as desired - from quick calculation in a few stages to full
definition of all variables
n Full-screen graphical input includes all dimensions for easy visualization
n Easy-to-understand anchor setting animations for added support
n Support for 13 different design methods and 16 languages
n Keep up to date with the latest standards with regular downloads

page 7
PC Software

Design software
and Technical
PC Software
Information

The challenge
Construction technology is in a state of ongoing development. Modern, eye-
catching designs, new materials and special requirements to be met by the
building all present a challenge and place high demands on facade design
engineers.
Medium duty

System MM
Light duty

IT systems have now become firmly established as essential tools for planners
and design engineers. They support these specialists in many areas of their work
and help them increase efficiency considerably, not only during planning but also
in the implementation phase.
Medium duty
System MQ

Research and development


In developing this new design software, Hilti paid close attention to the needs
and wishes of users active in this field. They requested that the volume of data
needed for installation of the software and subsequent updates should be kept
low, that it should be intuitive and easy to learn to use, that frequent users should
Hilti Pipe Rings

be able to make their own settings to suit their own needs, that the method of
calculation and the results should be transparent and well documented and,
moreover, that other documents and product information should be quickly and
easily available.

The Hilti solution


Medium duty
System MQ

Hilti offers a series of design applications, selection aids and sources of


HDG

information in the form of PC software under the name PROFIS. The fastening
design applications of particular interest to facade planning engineers are Hilti
PROFIS Anchor Channel and PROFIS Anchor. At Hilti, we not only guarantee the
quality of our products, we also believe that making the latest developments
Stainless Steel

in construction technology as well as advances in PC software available to


Medium duty
System MQ

customers in a form that meets their needs optimally is a task of central


importance.
System MI
HDG
Fixed points
System MQ
and sliders

These PC applications feature a When entering your data you can


uniform user interface that’s easy to choose between using the tabs or
Airconditioning
and Ventilation

become enter- ing the data directly in the


System MQ

familiar with. PROFIS is installed in graphical


modular form and calculations are 3D-view which, of course, can be ad-
based on the most recent CEN / TS justed during use, as desired.
status.
Firestop systems

page 8
Notes

page 9
Notes
Technical Information

Hilti. Outperform. Outlast.


M8

M 16
M 12
M 10
Threaded rod

888
350
200
100
50

444
175
100
50
100

296
116
66
33
150

222
87
50
25
200

Recommended load F (N)

177
68
32
13
250

137
40
19
0
300
Distance “L” between base material and pipe axes
Load and bend values for threaded rods (4.8)
Technical Information

page 13
System MQ System MQ System MQ System MQ System MM PC Software
Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
Technical Information

Copper pipes for water (DIN 1786 and 1754 (bare))


and Technical
PC Software
Information

Span width [in m] Fastening on concrete


(distance between channels)
Length of
Pipe Number
channel*
DN of pipes 1 1.5 2 2.5 3
[mm]
HKD HKD HKD Direct
HUS-I 6 Direct fastening** HUS-P 6
M6x25 M8x25 M10x25 fastening***
15 4 500 2 2 2 2 X-HS_X-U 32/ DKH 48 2 GHP20/XU-27
6 500 2 2 2 2 X-HS_X-U 32/ DKH 48 2 GHP20/XU-27
Medium duty

System MM

8 600 2 2 2 2 X-HS_X-U 32/ DKH 48 2 GHP20/XU-27


Light duty

10 700 2 2 2 2 X-HS_X-U 32/ DKH 48 2 GHP20/XU-27


20 4 600 2 2 2 2 X-HS_X-U 32/ DKH 48 2 GHP20/XU-27
6 600 2 2 2 2 X-HS_X-U 32/ DKH 48 2 GHP20/XU-27
8 700 2 2 2 2 X-HS_X-U 32/ DKH 48 2 GHP20/XU-27
10 800 2 2 2 2 X-HS_X-U 32/ DKH 48 2 GHP20/XU-27
25 4 600 2 2 2 2 X-HS_X-U 32/ DKH 48 2 GHP20/XU-27
6 600 2 2 2 2 X-HS_X-U 32/ DKH 48 2 GHP20/XU-27
8 700 2 2 2 2 X-HS_DKH 48 2 XU-27
Medium duty
System MQ

10 800 2 2 2 2 X-HS_DKH 48 2 XU-27


32 4 600 2 2 2 2 X-HS_DKH 48 2 XU-27
6 700 2 2 2 2 X-HS_DKH 48 2 XU-27
8 800 2 2 2 2 X-HS_DKH 48 2 XU-27
10 1000 2 2 2 2 X-HS_DKH 48 2 XU-27
40 4 600 2 2 2 2 X-HS_DKH 48 2 XU-27
6 700 2 2 2 2 X-HS_DKH 48 2 XU-27
8 800 2 2 2 2 X-HS_DKH 48 2 XU-27
50 2 600 2 2 2 2 X-HS_DKH 48 2 XU-27
Hilti Pipe Rings

4 700 2 2 2 2 X-HS_DKH 48 2 XU-27


6 800 2 2 2 2 X-HS_DKH 48 2
65 2 600 2 2 2 2 X-HS_DKH 48 2
4 800 2 2 2 2 X-HS_DKH 48 2
6 1000 2 2 2 2 2
80 2 600 2 2 2 2 X-HS_DKH 48 2
4 1000 2 2 2 2 X-HS_DKH 48 2
6 1200 3 3 3 3 3
100 2 600 2 2 2 2 2
Medium duty
System MQ

4 1000 3 3 3 3 3
HDG

Metal pipes for water, with insulation (DIN 2440)

Span width [in m] Fastening on concrete


(distance between channels)
Stainless Steel
Medium duty

Length of
System MQ

Pipe Number
channel*
DN of pipes 1 1.5 2 2.5 3
[mm]
HKD HKD HKD Direct
HUS-I 6 Direct fastening** HUS-P 6
M6x25 M8x25 M10x25 fastening***
15 4 500 2 2 2 2 X-HS_X-U 32/ DKH 48 2 GHP20/XU-27
6 500 2 2 2 2 X-HS_X-U 32/ DKH 48 2 GHP20/XU-27
8 600 2 2 2 2 X-HS_X-U 32/ DKH 48 2 GHP20/XU-27
10 700 2 2 2 2 X-HS_DKH 48 2 GHP20/XU-27
20 4 600 2 2 2 2 X-HS_DKH 48 2 GHP20/XU-27
System MI

6 600 2 2 2 2 X-HS_DKH 48 2 GHP20/XU-27


HDG

8 700 2 2 2 2 X-HS_DKH 48 2 XU-27


10 800 2 2 2 2 X-HS_DKH 48 2 XU-27
25 4 600 2 2 2 2 X-HS_DKH 48 2 XU-27
6 600 2 2 2 2 X-HS_DKH 48 2 XU-27
8 700 2 2 2 2 X-HS_DKH 48 2 XU-27
10 800 2 2 2 2 X-HS_DKH 48 2
32 4 600 2 2 2 2 X-HS_DKH 48 2 XU-27
6 700 2 2 2 2 X-HS_DKH 48 2 XU-27
Fixed points
System MQ
and sliders

8 800 2 2 2 2 X-HS_DKH 48 2
10 1000 2 2 2 2 X-HS_DKH 48 2
40 4 600 2 2 2 2 X-HS_DKH 48 2
6 700 2 2 2 2 X-HS_DKH 48 2
8 800 2 2 2 2 X-HS_DKH 48 2
50 2 600 2 2 2 2 X-HS_DKH 48 2
4 700 2 2 2 2 X-HS_DKH 48 2
6 800 2 2 2 2 X-HS_DKH 48 2
Airconditioning
and Ventilation

65 2 600 2 2 2 2 X-HS_DKH 48 2
System MQ

4 800 2 2 2 2 X-HS_DKH 48 2
6 1000 3 3 3 3 3
80 2 600 2 2 2 2 2
4 1000 3 3 3 3 3
6 1200 3 4 3 3 3
100 2 600 2 2 2 2 2
4 1000 3 4 3 3 3
Firestop systems

* Length of channel: Distance between fastening points; the channels can be 100 mm longer at each side.
MM-C16
** With respect to all relevant details for X-HS fasteners see technical data sheet: Fastening of MM-C channels with DX-fasteners
MM-C30 Valid for concrete strenght up to C 30/37 (X-HS U 32) and C 50/60 (DX-Kwik with X-HS DKH).
MM-C36 *** With respect to all relevant details see technical data sheet: Fastening of MM-C channels with DX-fasteners
For GX 120-ME Specifically to observe for channel fastenings directly to the ceiling:
For GX 120-ME gas-actuated tool: At least 5 fastening points per channel. All visible failures when driving fasteners must be repeated. Applies to concrete grades up to C30/37.
For DX 460-F8 powder-actuated fastening tool: At least 5 fastening points per channel. All visible failures when driving fasteners must be repeated. Applies to concrete grades up to C50/60.

page 14
Technical Information

Stainless steel pipes for water, with insulation (DIN 17455)

and Technical
PC Software

Information
Span width [in m] Fastening on concrete
(distance between channels)
Length of
Pipe Number
channel*
DN of pipes 1 1.5 2 2.5 3
[mm]
HKD HKD HKD Direct
HUS-I 6 Direct fastening** HUS-P 6
M6x25 M8x25 M10x25 fastening***
15 4 500 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
6 500 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27

Medium duty
System MM
Light duty
8 600 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
10 700 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
20 4 600 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
6 600 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
8 700 2 2 2 2 X-HS_DKH 48 2 GHP20/XU-27
10 800 2 2 2 2 X-HS_DKH 48 2 XU-27
25 4 600 2 2 2 2 X-HS_DKH 48 2 XU-27
6 600 2 2 2 2 X-HS_DKH 48 2 XU-27
8 700 2 2 2 2 X-HS_DKH 48 2 XU-27

Medium duty
System MQ
10 800 2 2 2 2 X-HS_DKH 48 2 XU-27
32 4 600 2 2 2 2 X-HS_DKH 48 2 XU-27
6 700 2 2 2 2 X-HS_DKH 48 2 XU-27
8 800 2 2 2 2 X-HS_DKH 48 2
10 1000 2 2 2 2 X-HS_DKH 48 2
40 4 600 2 2 2 2 X-HS_DKH 48 2 XU-27
6 700 2 2 2 2 X-HS_DKH 48 2 XU-27
8 800 2 2 2 2 X-HS_DKH 48 2

Hilti Pipe Rings


50 2 600 2 2 2 2 X-HS_DKH 48 2 XU-27
4 700 2 2 2 2 X-HS_DKH 48 2 XU-27
6 800 2 2 2 2 X-HS_DKH 48 2
65 2 600 2 2 2 2 X-HS_DKH 48 2
4 800 2 2 2 2 X-HS_DKH 48 2
6 1000 2 2 2 2 2
80 2 600 2 2 2 2 X-HS_DKH 48 2
4 1000 2 2 2 2 X-HS_DKH 48 2
6 1200 3 3 3 3 3

Medium duty
100 2 600 2 2 2 2 2

System MQ
4 1000 3 3 3 3 3

HDG
Metal composite pipes (Geberit Mepla)
Span width [in m] Fastening on concrete
(distance between channels)

Stainless Steel
Length of

Medium duty
Pipe Number

System MQ
channel*
DN of pipes 1 1.5 2 2.5 3
[mm]
HKD HKD HKD Direct
HUS-I 6 Direct fastening** HUS-P 6
M6x25 M8x25 M10x25 fastening***
15 4 500 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
6 500 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
8 600 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
10 700 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
20 4 600 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27

System MI
6 600 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
8 700 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27

HDG
10 800 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
25 4 600 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
6 600 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
8 700 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
10 800 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
32 4 600 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
6 700 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
Fixed points
System MQ

and sliders

8 800 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27


40 2 600 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
4 600 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
6 700 2 2 2 2 X-HS_X-U 32/DKH 48 2 GHP20/XU-27
50 2 600 2 2 2 2 X-HS_DKH 48 2 GHP20/XU-27
4 1000 2 2 2 2 X-HS_DKH 48 2 GHP20/XU-27
6 1000 2 2 2 2 X-HS_DKH 48 2 XU-27
65 2 600 2 2 2 2 X-HS_DKH 48 2 XU-27
Airconditioning
and Ventilation

4 1000 2 2 2 2 X-HS_DKH 48 2 XU-27


System MQ

6 1000 2 2 2 2 X-HS_DKH 48 2 XU-27

* Length of channel: Distance between fastening points; the channels can be 100 mm longer at each side.
MM-C16
** With respect to all relevant details for X-HS fasteners see technical data sheet: Fastening of MM-C channels with DX-fasteners
MM-C30 Valid for concrete strenght up to C 30/37 (X-HS U 32) and C 50/60 (DX-Kwik with X-HS DKH).
For GX 120-ME *** With respect to all relevant details see technical data sheet: Fastening of MM-C channels with DX-fasteners
Specifically to observe for channel fastenings directly to the ceiling:
For GX 120-ME gas-actuated tool: At least 5 fastening points per channel. All visible failures when driving fasteners must be repeated. Applies to concrete grades up to C30/37.
Firestop systems

For DX 460-F8 powder-actuated fastening tool: At least 5 fastening points per channel. All visible failures when driving fasteners must be repeated. Applies to concrete grades up to C50/60.

page 15
Sheet 1,25

Sheet 1,25
Weights and selection of channel without insulation

Sheet 1,13

Sheet 1,13
Sheet 1,0

Sheet 1,0
Sheet 0,88

Sheet 0.88
Technical Information

Sheet 0,75

Sheet 0.75

page 16
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Sheet 0,75

Sheet 0.75
Sheet 0,88

Sheet 0.88
Sheet 1,0

Sheet 1,0
Sheet 1,13

Sheet 1,13
Weights and selection of channel with insulation

Sheet 1,25

Sheet 1,25
Technical Information

page 17
System MQ System MQ System MQ System MQ System MM PC Software
Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
Sheet 1,25
Sheet 1,25
Weights and selection of channel without insulation

Sheet 1,13
Sheet 1,13

Sheet 1,0
Sheet 1,0

Sheet 0.88
Sheet 0,88
Technical Information

Sheet 0.75
Sheet 0,75

page 18
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Sheet 0,75

Sheet 0.75
Sheet 0,88

Sheet 0.88
Sheet 1,0

Sheet 1,0
Sheet 1,13

Sheet 1,13
Weights and selection of channel with insulation

Sheet 1,25

Sheet 1,25
Technical Information

page 19
System MQ System MQ System MQ System MQ System MM PC Software
Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
Sheet 1,25
Sheet 1,25
Weights and selection of channel without insulation

Sheet 1,13
Sheet 1,13

Sheet 1,0
Sheet 1,0

Sheet 0.88
Sheet 0,88
Technical Information

Sheet 0.75
Sheet 0,75

page 20
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Sheet 0,75

Sheet 0.75
Sheet 0,88

Sheet 0.88
Sheet 1,0

Sheet 1,0
Sheet 1,13

Sheet 1,13
Weights and selection of channel with insulation

Sheet 1,25

Sheet 1,25
Technical Information

page 21
System MQ System MQ System MQ System MQ System MM PC Software
Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
Technical Information

page 22
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Maximum loads for a fire rating of 30 minutes Maximum loads for a fire rating of 90 minutes

Fire rating F30 Fire rating F90

Installation channels MQ-41/3 Installation channels MQ-41/3

Fastening means M10 OR M12 anchor / threaded rod with MQZ-L11 or M10 OR M12 anchor / threaded rod with HQZ-L11 or
Fastening means
MQZ-L13 baseplates MQZ-L13 baseplates

Type of fastening suspended direct suspended suspended suspended direct suspended direct Type of fastening suspended direct suspended suspended suspended direct suspended direct

Structural span ≤ 35 50 60 70 Structural span ≤ 35 50 60 70

(cm) 3.00 - 2.00 - 1.70 - 1.50 - (cm) 1.00 - 0.90 - 0.80 - 0.80 -

Total Uniform load ≤ (kN) 1.30 1.80 0.85 1.50 0.70 1.30 0.60 1.10 Total Uniform load ≤ (kN) 0.40 0.65 0.35 0.50 0.35 0.45 0.35 0.40

1 single load of ≤ (kN) 0.75 1.20 0.50 0.95 0.40 0.80 0.35 0.70 1 single load of ≤ (kN) 0.25 0.40 0.20 0.31 0.20 0.28 0.20 0.25

2 single load of ≤ (kN) 0.50 0.90 0.35 0.70 0.30 0.62 0.25 0.51 2 single load of ≤ (kN) 0.18 0.30 0.14 0.23 0.14 0.21 0.14 0.19

3 single load of ≤ (kN) 0.30 0.58 0.24 0.50 0.20 0.42 3 single load of ≤ (kN) 0.11 0.19 0.11 0.17 0.11 0.15

4 single load of ≤ (kN) - 0.20 0.42 0.17 0.35 4 single load of ≤ (kN) - 0.09 0.14 0.09 0.12
- -
5 single load of ≤ (kN) - 0.15 0.30 5 single load of ≤ (kN) - 0.08 0.11

Maximum loads for a fire rating of 60 minutes Maximum loads for a fire rating of 120 minutes

Fire rating F60 Fire rating F120

Installation channels MQ-41/3 Installation channels MQ-41/3

M10 OR M12 anchor / threaded rod with MQZ-L11 or M10 OR M12 anchor / threaded rod with HQZ-L11 or
Fastening means Fastening means
MQZ-L13 baseplates MQZ-L13 baseplates

Type of fastening suspended direct suspended suspended suspended direct suspended Type of fastening suspended direct suspended suspended suspended direct suspended direct

Structural span ≤ 35 50 60 70 Structural span ≤ 35 50 60 70

1.60 - 1.10 - 1.00 - 1.00 - (cm) 0.80 - 0.75 - 0.70 - 0.70 -


(cm)
Total Uniform load ≤ (kN) 0.70 0.95 0.50 0.80 0.42 0.70 0.42 0.60 Total Uniform load ≤ (kN) 0.30 0.60 0.35 0.45 0.30 0.40 0.30 0.35

1 single load of ≤ (kN) 0.40 0.60 0.30 0.50 0.25 0.44 0.25 0.38 1 single load of ≤ (kN) 0.18 0.38 0.18 0.28 0.18 0.25 0.18 0.23

2 single load of ≤ (kN) 0.25 0.45 0.20 0.38 0.18 0.33 0.18 0.28 2 single load of ≤ (kN) 0.12 0.28 0.12 0.21 0.12 0.18 0.12 0.17

3 single load of ≤ (kN) 0.16 0.31 0.14 0.27 0.14 0.23 3 single load of ≤ (kN) 0.10 0.17 0.10 0.15 0.10 0.13

4 single load of ≤ (kN) - 0.11 0.22 0.11 0.19 4 single load of ≤ (kN) - 0.08 0.12 0.08 0.11
- -
5 single load of ≤ (kN) - 0.10 0.16 5 single load of ≤ (kN) - 0.07 0.10
Technical Information

page 23
System MQ System MQ System MQ System MQ System MM PC Software
Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
Technical Information

page 24
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
System MM
Light Duty
Medium Duty
System MM

Hilti. Outperform. Outlast.


System MM

Description Pages

Technical Data - Channel Sections 28

Installation channel MM-C 29

Bracket MM-B 30

Technical data for brackets 31

T-head bolt MM-ST 32

Pipe ring saddle MM-S 33

Wing nut MM-WN 34

Angle MM-A-90 / MM-AH-90 35

Rail support MM-R-16-36 36

Beam clamp MM-T-16-36 37

Rubber inlay MM-RI 38

Channel end cap MM-E 39

page 27
System MM

Technical data Channel sections


and Technical
PC Software

Definition of axes
Information




) )





H H 
\D[LV 
H H 
RSHQ
]D[LV
MM-C-16 MM-C-30 MM-C-36 MM-C-45
Channel wall thickness t [mm] 1,0 1,0 1.75 / 1.0 1.75
Medium duty

System MM

Cross-sectional area A [mm²] 72,0 100,0 159,0 215.0


Light duty

Channel weight [g/m] 565,0 779,0 1287,0 1762,.0


Delivered length [m] 2 2/3 2/3 3/6
Material
Permissible stress σperm [N/mm²] 188,0 188,0 188,0 188,0
E-Modul [N/mm²] 190000 190000 190000 190000
Surface
Medium duty
System MQ

Sendzimir galvanised • • • •
Cross-section values
Y-axis
Axis of gravity “open” 1) e1 [mm] 9,26 16,58 19,77 23,78
Axis of gravity e2 [mm] 7,08 13,75 16,74 21,62
Moment of inertia Iy [cm4] 0,25 1,20 3,01 5,33
Hilti Pipe Rings

Section modulus “open” Wy1 [cm³] 0,27 0,73 1,52 2,24


Section modulus Wy2 [cm³] 0,35 0,88 1,71 2,47
Radius of gyration iy [cm] 0,59 1,10 1,38 1,57
Permissible moment 2) My [Nm] 50,80 137,2 285,8 421,7
Z-axis
Moment of inertia Iz [cm4] 1,03 1,58 2,73 3,94
Section modulus Wz [cm³] 0,69 1,05 1,71 2,46
Radius of gyration iz [cm] 1,20 1,25 1,31 1,35
Medium duty
System MQ

Selection of channel section:


HDG

• The given data is based on a single span (simply-supported beam) bearing a single load, F(N), at mid span, L/2.
• If several loads are acting on a single span (simply-supported beam), these may be summated and regarded as
a single load acting at mid span. By taking this approach, the design calculation is on the safe side. (➝ Channel
selection table).
Stainless Steel

• The permissible stress in the steel and the max. deflection, L/200, are not exceeded with the given max. span
Medium duty
System MQ

widths, L (mm).
• The permissible stress σD / γG/Q where γ =1.4. σD results from the higher yield strength (point) resulting from cold
forming as per DAST-RILI 016 dated 1992: σD = fyk / γM where γM = 1.1

Channel selection table for MM-C (simply supported)


System MI
HDG
Fixed points
System MQ
and sliders

Max. Load / Deflection

Span with L (cm)


Airconditioning
and Ventilation

System MQ
Firestop systems

1) The smaller value (Wy1, Wy2) is decisive for the calculated bending dimension (Wy1 = Iy / e1 or Wy2 = Iy / e2 )
2)

page 28
System MM

Installation channel

and Technical
MM-C

PC Software

Information
The innovative channel system for light and medium-duty installations

Medium duty
System MM
Light duty
Medium duty
System MQ
Applications Technical data
nn Light and medium-duty pipe support systems MM-C
nn Fastening ventilation ducts and cable trays
Material composition S250GD as per DIN EN 10346
Surface Finish Sendzimir galvanized
Advantages

Hilti Pipe Rings


nn C-profile with serrated edges
nn Reinforced slots for greater versatility
nn Dimension marks assist installation
nn Modular channel system

Medium duty
System MQ
   4

HDG
[






Stainless Steel
Medium duty


System MQ





Nr. Height - H Length - L Thickness Weight per m Order designation Sales Item Number
length Quantity

 16 mm 2m 1 mm 565 g Install. channel MM-C-16 2m 16 m 00418748


 16 mm 3m 1mm 565 g Install. channel MM-C-16 3m 18 m 2038061*

System MI
 30 mm 3m 1 mm 779 g Install. channel MM-C-30 3m M10 18 m 00418776

HDG
 30 mm 3m 1 mm 779 g Install. channel MM-C-30 3m M10 18 m 2038062*
 36 mm 3m 1.75 mm 1.29 kg Install. channel MM-C-36 3m M10 18 m 00418751
4 45 mm 3m 1.75 mm 1.88 kg Install. channel MM-C-45 3m 18 m 2048104
Fixed points
System MQ

and sliders

* Check the availability with your logistic (available in GCC).


Airconditioning
and Ventilation
System MQ

Firestop systems

page 29
System MM

Bracket
and Technical

MM-B
PC Software
Information

High-quality bracket for various applications


Medium duty

System MM
Light duty
Medium duty
System MQ

Applications Technical data


nn Installation of pipe supports, air ducts and cable trays MM-B
Material composition Material channel: S235 JR
Advantages as per DIN EN 10025-2,
nn Serrated C-section Material plate: S355 MC
Hilti Pipe Rings

as per DIN EN 10149-2


nn Reinforced slots for greater versatility and rigidity
Surface Finish Galvanized
nn Matched to anchor loading capacity
nn Dimension marks assist installation

 
Medium duty
System MQ
HDG
Stainless Steel
Medium duty
System MQ

Nr. Length - L Bar height Weight Order designation Sales Quantity Item Number

 200 mm 30 mm 278 g Bracket MM-B-30/200 10 pc 00418752


 300 mm 30 mm 356 g Bracket MM-B-30/300 10 pc 00418753
 300 mm 36 mm 585 g Bracket MM-B-36/300 10 pc 00418754
 450 mm 36 mm 778 g Bracket MM-B-36/450 10 pc 00418755
System MI
HDG

 600 mm 36 mm 971 g Bracket MM-B-36/600 10 pc 00418756


Fixed points
System MQ
and sliders

Angle brace
MM-AB
Airconditioning
and Ventilation

System MQ

Ordering
Firestop systems

Length - L Height - H Angle Weight Order designation Sales Quantity Item Number

202 mm 202 mm 45 ° 230 g Angle brace MM-AB 10 pc 00418772

page 30
System MM

Technical data for brackets

and Technical
PC Software
Type of load 1: uniform Type of load 2: single Type of load 3 Type of load 4 Type of load 5

Information
F1 F1 F1F1 FF1F12 F2 F1F1 F2 F2 F3 FF31 F3F2 F2 FF3 1F3F2F3 F2 F3 FF32 F3F2 F3 F3 F3 F3 F3 F3
F1 = q x l F1 = q1x/2l 1/ F1 =
2 q x l1/2 F11/=2 q x l 1/2 F1 1=/2 q x l 1/2 1/3 1/12/3 1/3 1/2 1/
1/2 1/ 11/4/ 1/4 1/41/31/4 1/3 1/31/ 1/1/31/ 1/13/ 1/3 1/4 11/4/3 1/41/31/4 1/3 1/4 1/4 1/4 1/4 1/ 1/ 1/ 1/
4 4 4 4
3 3 3 4 4 4 4

F1 [N] F1 [N] F1 [N] F2 [N] F3 [N]


Channel
Bracket L (mm) HST M10 or HUS 8 HST M10 or HUS 8 HST M10 or HUS 8 HST M10 or HUS 8 HST M10 or HUS 8
MM-B-30/200 200 870 870 430 430 290
MM-B-30/300 300 580 580 290 290 190
MM-B-36/300 300 1230 1230 610 610 410

Medium duty
System MM
MM-B-36/450 450 810 810 400 400 270

Light duty
MM-B-36/600 600 610 610 300 300 200

Technical data for brackets with angle brace (channel opening facing down)
Type of load 1: uniform Type of load 2: single Type of load 3 Type of load 4 Type of load 5

Fz Fz Fz Fz FFzFz z Fz FzFz Fz Fz Fz FFz zFFzz Fz FFz z FzFFz z Fz Fz Fz FFzz Fz Fz Fz Fz Fz Fz Fz


Fz = q x l Fz = q 1x/2l 1/
2 1/2x l F1z/2= q x l 1/ Fz = 1q
Fz = q /2 x l
1/2 1 11/2 1 1/
/3 /3 /3 2
11/ 1 11/ 1/ 11/ 1/1 1 1 1 1/1 11/ 11/ 1 11/ 1 1/ 1/ 1/ 1/ 1/ 1/
/23 /3 4/3 4 /43 4/3 /3 /4 /4 3/4 /34 /43 /4 /43 /4 3 3 4 4 4 4
1/ 1/ 1/ 1/
4 4 4 4
2

Medium duty
System MQ
F1 [N] F1 [N] F1 [N] F2 [N] F3 [N]
Channel

Bracket L (mm) HST M10 or HUS 8 HST M10 or HUS 8 HST M10 or HUS 8 HST M10 or HUS 8 HST M10 or HUS 8
MM-B-30/200 200 2990 2730 1490 1490 990
MM-B-30/300 300 1990 1990 990 990 660
MM-B-36/300 300 1990 1990 990 990 660
MM-B-36/450 450 1320 1320 660 660 440
MM-B-36/600 600 990 990 470 490 330

Hilti Pipe Rings


Technical data for brackets with angle brace (channel opening facing up)
Type of load 1: uniform Type of load 2: single Type of load 3 Type of load 4 Type of load 5

Fz Fz Fz Fz FFzFz z Fz Fz Fz Fz FFzz FzFzFzFz Fz Fzz FFzz FzFz Fz Fz FFzz Fz Fz Fz Fz Fz Fz Fz


Fz = q x l Fz = 1q/2 x l 1/2 Fz = q1/2x l Fz 1=/2 q x l 1/2Fz = q
1/2x l 1/ 1/3 1/3 1/3
2 2 1/2 1/12/ 1/ 1/4 11//4 1/41/1/4 1/ 1/ 1/ 11// 1/ 1/ 1/ 11// 1/ 11// 1/1/ 1/ 1/ 1/ 1/ 1/
3 3 3 4 43 4 3 4 34 4 43 4 3 1/4 1/4 1/4 1/4
3 3 3 3 4 4 4 4

F1 [N] F1 [N] F1 [N] F2 [N] F3 [N]


Channel
Bracket L (mm) HST M10 or HUS 8 HST M10 or HUS 8 HST M10 or HUS 8 HST M10 or HUS 8 HST M10 or HUS 8
MM-B-30/200 200 4590 2730 2290 2050 1360

Medium duty
System MQ
MM-B-30/300 300 3060 3060 1360 1530 1020
MM-B-36/300 300 3060 3060 1530 1530 1020

HDG
MM-B-36/450 450 2030 2030 1010 1010 670
MM-B-36/600 600 1520 1520 470 760 500

Load values are for grade ≥ C20/25 concrete.


The bracket’s own weight has been allowed for.
The loads apply only if the bracket is fastened away from a building component edge (fastenings made at component edges must be designed separately).

Stainless Steel
Separate verification must be provided that forces are transferred to the respective base material, i.e. steel and concrete.

Medium duty
System MQ
The application guidelines in anchor approvals must be observed. Loading values according to approval status January 2010.
The deflection (deformation) of L/150 was observed in all cases, this being measured at the point of load application.

System MI
HDG
Fixed points
System MQ

and sliders
Airconditioning
and Ventilation
System MQ

Firestop systems

page 31
System MM

T-head bolt
and Technical

MM-ST
PC Software
Information

With a unique fastening mechanism for great versatility and higher productivity
Medium duty

System MM
Light duty
Medium duty
System MQ

Technical data
Applications
nn Fastening light and medium-duty piping MM-ST
Material composition Plate: DD11 as per DIN EN 10111,
Nut: DC04 as per DIN EN 10130
Advantages
Surface Finish Galvanized
nn Extremely fast installation thanks to the unique fastening
Hilti Pipe Rings

mechanism
nn Easy height adjustment within the installation channel
nn Greater versatility thanks to various threaded rod lengths
nn Serrated surfaces for easy, accurate adjustment
Medium duty
System MQ

 
HDG

0[

Stainless Steel
Medium duty
System MQ
System MI

Nr. Connection Weight Order designation Sales Quantity Item Number


HDG

thread

 M8 41.3 g T-head bolt MM-ST M8x40 50 pc 00418777


 M8 47.4 g T-head bolt MM-ST M8x60 50 pc 00418778
 M8 53.6 g T-head bolt MM-ST M8x80 50 pc 00418779
 M8 60.5 g T-head bolt MM-ST M8x100 50 pc 00418780
Fixed points
System MQ
and sliders

 M8 78.5 g T-head bolt MM-ST M8x150 20 pc 02030481


 M8 92.5 g T-head bolt MM-ST M8x200 20 pc 02030482
 M10 52.8 g T-head bolt MM-ST M10x40 50 pc 00418782
 M10 62.6 g T-head bolt MM-ST M10x60 50 pc 00418791
 M10 72.5 g T-head bolt MM-ST M10x80 50 pc 00418792
Airconditioning
and Ventilation

System MQ

 M10 82.1 g T-head bolt MM-ST M10x100 50 pc 00418793

Rec. tensile load, Zrec (N) Rec. shear load, Qrec (N) Bending moment, Tighting torque,
threaded rod 4.6 Md (Nm)
Item no. Channel I Channel II Channel I Channel II (Nm)1)
MM-ST M8 1200 1500 1000 1000 6,4 12
Firestop systems

MM-ST M10 1200 1500 1000 1000 12,8 16

Channel I: MM-C-16, MM-C-30


Channel II: MM-C-36, MM-C-45
1)
Calculation as per DIBt

page 32
System MM

Pipe ring saddle

and Technical
MM-S

PC Software

Information
The superior solution for attaching threaded rods to channels

Medium duty
System MM
Light duty
Medium duty
System MQ
Applications Technical data
nn Installing threaded rods for pipe and air duct suspension systems MM-S
Material composition S355 MC as per DIN EN 10149-2
Advantages Surface Finish Galvanized

Hilti Pipe Rings


nn Suitable for all three MM channel profiles
nn Can be fitted and removed without need for tools
nn Easy alignment in the right position

Medium duty
System MQ

HDG
Stainless Steel
Medium duty
System MQ
Connection thread Weight Order designation Sales Quantity Item Number

M6 25 g Pipe ring saddle MM-S M6 25 pc 00418759

System MI
M8 25 g Pipe ring saddle MM-S M8 25 pc 00418760

HDG
M10 24 g Pipe ring saddle MM-S M10 25 pc 00418761

Rec. tensile load, Zrec (N) Rec. shear load, Qrec (N) Bending moment, Tighting torque,
Fixed points
System MQ

and sliders

threaded rod 4.6 Md (Nm)


Item no. Channel I Channel II Channel I Channel II (Nm)1)
MM-S M6 1200 1500 800 1000 2,6 5
MM-S M8 1200 1500 800 1000 6,4 12
MM-S M10 1200 1500 800 1000 12,8 16
Airconditioning
and Ventilation
System MQ

Channel I: MM-C-16, MM-C-30


Channel II: MM-C-36, MM-C-45
1)
Calculation as per DIBt
Firestop systems

page 33
System MM

Wing nut
and Technical

MM-WN
PC Software
Information

Handy, one-piece part for fitting connectors to channels


Medium duty

System MM
Light duty
Medium duty
System MQ

Applications Technical data


nn Fitting connectors to installation channels MM-WN
Material composition Nut: DC04 as per DIN EN 10130,
Advantages Wing: PA
nn Makes in-plane installation on channels possible Surface Finish Galvanized
Hilti Pipe Rings

nn Allows direct attachment to channels


nn Handy, one-piece part
Medium duty
System MQ
HDG
Stainless Steel
Medium duty
System MQ

Connection thread Weight Order designation Sales Quantity Item Number

M6 9.3 g Wing nut MM-WN M6 50 pc 00418764


M8 9.6 g Wing nut MM-WN M8 50 pc 00418765
System MI
HDG

M10 9.2 g Wing nut MM-WN M10 50 pc 00418766

Rec. tensile load, Zrec (N) Rec. shear load, Qrec (N) Tighting torque,
Item no. Channel I Channel II Channel I Channel II Md (Nm)
Fixed points
System MQ
and sliders

MM-WN M6 1200 1200 700 1000 5


MM-WN M8 1200 1500 1000 1000 5
MM-WN M10 1200 1500 1000 1000 5

Channel I: MM-C-16, MM-C-30


Airconditioning
and Ventilation

Channel II: MM-C-36, MM-C-45


System MQ
Firestop systems

page 34
System MM

Angle

and Technical
MM-A-90 / MM-AH-90

PC Software

Information
Ideal for use with channels in various positions

Medium duty
System MM
Light duty
Medium duty
System MQ
Applications Technical data
nn Assembly of frames and supporting structures MM-A-90
nn Joining channels at right angles
Material composition DC04 as per DIN EN 10130
nn Recommended for U-frame structures
Surface Finish Galvanized
Additional product information Pre-assembled bolts
Advantages

Hilti Pipe Rings


nn Pre-assembled for rapid installation
nn Can be fitted to channels in various positions

 

Medium duty
System MQ

HDG
Stainless Steel
Medium duty
System MQ
 

System MI
HDG
Fixed points
System MQ

and sliders

Nr. Angle Weight Order designation Sales Quantity Item Number

 90 ° 75 g Angle MM-A-90 20 pc 00418757


 90 ° 52 g Angle MM-AH-90 20 pc 00418758

Rec. tensile load, Zrec (N) Rec. shear load, Qrec (N) Tighting torque,
Airconditioning
and Ventilation

Md (Nm)
System MQ

Item no. Channel I Channel II Channel I Channel II


MM-A-90 1000 1000 1000 1000 12
MM-AH-90 500 500 500 500 12

Channel I: MM-C-16, MM-C-30


Firestop systems

Channel II: MM-C-36, MM-C-45

Supported at both ends

page 35
System MM

Rail support
and Technical

MM-R-16-36
PC Software
Information

Pre-assembled support for quick and reliable installation


Medium duty

System MM
Light duty
Medium duty
System MQ

Applications Technical data


nn Fastening channels to any base material MM-R-16-36
Material composition Material: DC04 as per DIN EN 10130,
Advantages Plate: DD11 as per DIN EN 10111
nn Pre-assembled for rapid installation Surface Finish Galvanized
Hilti Pipe Rings

nn Reliable and easy to use Additional product Pre-assembled bolts


nn Very easy alignment of the pre-assembled system information
For use with MM-C-16, MM-C-30, MM-C-36
Medium duty
System MQ
HDG
Stainless Steel
Medium duty
System MQ

Angle Weight Order designation Sales Quantity Item Number

90 ° 390 g Rail support MM-R-16-36 10 pc 00418762


System MI
HDG

Rec. tensile load, Zrec (N) Rec. shear load, Qrec (N) Tighting torque,
Item no. Channel I Channel II Channel I Channel II Md (Nm)
Fixed points
System MQ
and sliders

MM-R-16-36 1200 1500 1000 1000 12

Channel I: MM-C-16, MM-C-30


Channel II: MM-C-36, MM-C-45
Airconditioning
and Ventilation

System MQ
Firestop systems

page 36
System MM

Beam clamp

and Technical
MM-T-16-36

PC Software

Information
New beam clamp allows fastening from both sides of the channel

Medium duty
System MM
Light duty
Medium duty
System MQ
Applications Technical data
nn Fastening all three types of MM channel profiles to steel beams MM-T-16-36
nn The beam clamp set fits all common T-beams (max. clamping
Material composition Material: EN-GJMB-550-4 as per
thickness 23mm)
DIN EN 1562,
Screw: grade 8.8

Hilti Pipe Rings


Advantages Surface Finish Galvanized
nn Easy alignment in the right position Additional product Extremely fast installation of MM-C-16,
information MM-C-30, MM-C-36 channels on steel
beams without drilling or welding
For use with MM-C-16, MM-C-30, MM-C-36, MM-C-45

Medium duty
System MQ

HDG
Stainless Steel
Medium duty
System MQ
System MI
Weight Order designation Sales Quantity Item Number

HDG
106 g Beam clamp MM-T-16-36 20 00418763

Tighting torque, Bolt Tighting torque, Counter nut


Fixed points

Rec. tensile load, Zrec (N)


System MQ

and sliders

Md (Nm) Md (Nm)
Item no. Channel I Channel II
MM-T-16-36 1200 2500 3 10

Channel I: MM-C-16, MM-C-30


Channel II: MM-C-36, MM-C-45
Airconditioning
and Ventilation
System MQ

Firestop systems

page 37
System MM

Rubber inlay
and Technical

MM-RI
PC Software
Information

The ideal acoustic insulation inlay for air duct supports


Medium duty

System MM
Light duty
Medium duty
System MQ

Applications Technical data


nn Acoustic insulation of MM channel air duct supports MM-RI
nn Insulating layer between M8 and M10 threaded rod and the
Material composition EPDM
ventilation duct
Hardness Insulation Material 55° +/- 5° Shore A

Advantages Temperature resistance -40°C - 110°C


Hilti Pipe Rings

temperature range
nn Suitable for all three types of MM channel profiles and M8/M10
threaded rods Average noise reduction 14 dB(A)
nn Prevents direct contact between the air duct and the channel For use with MM-C-16, MM-C-30, MM-C-36,
MM-C-45
nn Large contact area between the channel insulation profile and
the air duct avoids transmission of vibration and
structure-borne sound
Medium duty

nn Quick and easy installation in the channel


System MQ
HDG

Weight Order designation Sales Quantity Item Number

333 g Rubber inlay MM-RI 10cm 100 00418768


6.66 kg Rubber inlay MM-RI 20m 1 00418767
Stainless Steel
Medium duty
System MQ

Channel washer
MM-CW
For easy installation of threaded rods
System MI
HDG
Fixed points
System MQ
and sliders

Applications Technical data


nn Optimization of suspension systems using channels and threaded MM-CW
rods
Airconditioning
and Ventilation

Material composition DD11 steel as per DIN EN 10111


System MQ

nn Used together with MM channels, wing nuts and brackets


Surface Finish Galvanized

Advantages For use with MM-C-16, MM-C-30, MM-C-36,


MM-C-45
nn Fits the MM channel system perfectly
Firestop systems

Weight Order designation Sales Quantity Item Number

15 g Channel washer MM-CW M8 20 pc 00418769


15 g Channel washer MM-CW M10 20 pc 00418770

page 38
System MM

Channel end cap

and Technical
MM-E

PC Software

Information
Suitable for all installation channels

Medium duty
System MM
Light duty
Medium duty
System MQ
Applications Technical data
nn Installation channel edge protection MM-E
Additional product information Made of polypropylene (PP),
Advantages suitable for all MM installation
channels
nn Suitable for all installation channels

Hilti Pipe Rings


   4



Medium duty
System MQ


HDG


Stainless Steel
Nr. For use with Weight Order designation Sales Quantity Item Number

Medium duty
System MQ
 MM-C-16 2g Channel end cap MM-E-16 50 pc 00418773
 MM-C-30 3.2 g Channel end cap MM-E-30 50 pc 00418774
 MM-C-36 4g Channel end cap MM-E-36 50 pc 00418775
4 MM-C-45 Channel end cap MM-E-45 50 pc 2048095

System MI
HDG
Fixed points
System MQ

and sliders
Airconditioning
and Ventilation
System MQ

Firestop systems

page 39
Notes
MQ Channel Installation
Galvanized
Hilti. Outperform. Outlast.

page 22
System MQ

Description Pages

Technical Data 44-47

Installation Channels - Single and Double 48

Anchor channel HAC-30 (Cast-in) 49

Brackets and Angle brace 50

Push-button, wingnut and Pipe ring saddles 51-52

Channel connectors 53-56

Channel base connectors 57-58

Beam clamps 59-62

Swivel beam blamp MQT-G and Retaining strap for swivel beam clamp
63
MQT-G

Clamping bracket MQT-K 64

Channel Accessories 65

3D System 66

MQ Eco connectors 67-68

MQP-E-N Elevator wall base 69

Accessories (Threaded rods, nuts, washers etc) 70-72

page 43
System MQ

Technical data Channel sections


and Technical
PC Software

2.5
Information

2.75
Definition of axes 2

124
2.5

124
F F

82.6
2

72
e2 e1

2
2

52

41.2
2.75

41.3
y-axis

41.3
31
20.6
e1 e2
41.3 41.3 41.3 41.3 41.3 41.3 41.3 41.3 41.3 41.3
"open" z-axis
Medium duty

System MM
Light duty
Medium duty
System MQ
Hilti Pipe Rings
Medium duty
System MQ
HDG

Selection of channel section:


The given data is based on a single span (simply-supported beam) bearing a single load, F (kN), at mid span, L/2.
If several loads are acting on a single span (simply-supported beam), these may be summated and regarded as a single load actin g at mid span. By taking this ap-
proach, the design calculation is on the safe side. ( Channel selection table).
The permissible stress in the steel and the max. deflection, L/200, are not exceeded with the given max. span widths, L (cm).
The permissible stress σD / γG/Q where γ = 1.4. σD results from the higher yield strength (point) resulting from cold forming as per DAST-RILI 016 dated 1992:
σD = f yk / γM where γM = 1.1
Stainless Steel
Medium duty
System MQ

Max. span width, L (cm) / deflection, f (mm)


F (kN)
0 .2 5 1 3 3 6 .7 2 1 8 1 0 .9 3 0 6 1 5 .3 3 3 7 1 6 .8 4 1 9 2 0 .9 5 9 9 2 9 .9 2 8 8 1 4 .4 6 1 4 3 0 .7 9 3 6 4 6 .8 1 0 3 4 5 1 .7
0 .5 0 9 5 4 .8 1 5 9 7 .9 2 2 6 1 1 .3 2 5 4 1 2 .7 3 2 1 1 6 .0 4 8 2 2 4 .1 2 1 6 1 0 .8 4 9 6 2 4 .8 8 2 1 4 1 .0 9 3 8 4 6 .9
0 .7 5 7 8 3 .9 1 3 1 6 .5 1 8 7 9 .3 2 1 2 1 0 .6 2 6 8 1 3 .4 4 1 1 2 0 .5 1 7 9 9 .0 4 2 4 2 1 .2 7 3 5 3 6 .8 4 3 .0
1.00
System MI

1 .2 5 5 1 1 .8 94 4 .0 1 4 1 6 .6 166 8 .3 2 1 1 1 0 .5 3 2 9 1 6 .5 1 4 0 7 .0 340 1 7 .0 618 3 0 .9 745 3 7 .2


HDG

1 .5 0 4 2 1 .2 78 2 .8 1 1 8 4 .6 152 7 .6 1 9 3 9 .7 3 0 3 1 5 .1 1 2 0 5 .3 313 1 5 .6 576 2 8 .8 701 3 5 .0


1 .7 5 36 < 1 67 2 .0 1 0 1 3 .4 139 6 .7 1 7 5 8 .3 2 8 2 1 4 .1 1 0 3 3 .9 288 1 4 .1 541 2 7 .0 663 3 3 .1
2 .0 0 32 < 1 59 1 .6 8 9 2 .6 122 5 .2 1 5 4 6 .5 2 6 4 1 3 .2 9 0 3 .0 254 1 1 .0 511 2 5 .6 630 3 1 .5
2 .2 5 28 < 1 52 1 .2 7 9 2 .1 108 4 .1 1 3 7 5 .1 2 3 8 1 0 .8 8 0 2 .4 227 8 .9 486 2 4 .3 601 3 0 .1
2 .5 0 25 < 1 47 1 .0 7 1 1 .7 98 3 .3 1 2 3 4 .2 2 1 5 8 .9 7 2 1 .9 205 7 .3 464 2 3 .2 576 2 8 .8
2 .7 5 23 < 1 43 < 1 65 1 .4 89 2 .8 1 1 2 3 .5 1 9 6 7 .4 6 6 1 .6 187 6 .1 444 2 2 .2 554 2 7 .7
Fixed points
System MQ
and sliders

3 .0 0 21 < 1 39 < 1 59 1 .2 82 2 .3 1 0 3 2 .9 1 8 0 6 .3 6 0 1 .3 172 5 .1 415 1 9 .7 534 2 6 .7


3 .5 0 18 < 1 34 < 1 51 <1 70 1 .7 8 8 2 .2 1 5 5 4 .6 – – 148 3 .8 360 1 5 .0 499 2 4 .9
4 .0 0 16 < 1 29 < 1 44 <1 61 1 .3 7 7 1 .7 1 3 6 3 .6 – – 129 2 .9 317 1 1 .7 466 2 2 .9
4 .5 0 14 < 1 26 < 1 39 <1 54 1 .0 6 9 1 .3 1 2 1 2 .8 – – 115 2 .3 284 9 .4 418 1 8 .7
5 .0 0 12 < 1 23 < 1 36 <1 49 <1 6 2 1 .1 1 0 9 2 .3 – – 104 1 .9 256 7 .7 380 1 5 .5
6 .0 0 10 < 1 19 < 1 30 <1 41 <1 52 < 1 91 1 .6 – – 87 1 .3 215 5 .5 320 1 1 .1
Airconditioning
and Ventilation

System MQ

7 .0 0 9 <1 17 < 1 25 <1 35 <1 44 < 1 78 1 .2 – – – – 185 4 .0 276 8 .3


8 .0 0 7 <1 14 < 1 22 <1 31 <1 39 < 1 68 <1 – – – – 162 3 .1 243 6 .5
Selection example: Single load
1.0 kN ( ≈100 kg) should be carried by a channel with a channel span F [kN]
width L = 100 cm (single span simply supported). Conversion kp kg N kN
Solution: 1 kp – 1 10 0.01
L/2 L/2
Firestop systems

Select the line showing the load, F = 1.0 kN. 1 kg 1 – 10 0.01 L [cm]
The MQ-31 to MQ-124X D channels can be used because the 1N 0.1 0.1 – 0.001
permissible span width (tabulated value) is larger or equal
to the required span, L = 100 cm. 1 kN 100 100 1000 – F

1)
The smaller value (W y1 , W y2 ) is decisive for the calculated bending dimension (W y1 = I y/e 1 or W y2 = I y/e 2).
2)
Perm. M y = σzul. · min. (W y1 , W y2 ) f[mm]

page
page 244
System
System

page 25
MQ
SystemMQ

page 45
MQ

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
System MQ

Load, F (kN)

Channel selection diagram 25.00


and Technical
PC Software
Information

Single span MQ-72

(simply supported) 20.00


with single load at mid span, L/2
All values were calculated for a permissible stress of σzul.
(See technical data for channel section.) and a deflection of L/200. 15.00
Medium duty

System MM

MQ-52
F[kN]
Light duty

10.00 MQ-41/3

MQ-41
L/2 L/2
L[cm] 5.00 MQ-31

MQ-21
Medium duty
System MQ

0.00
0 25 50 100 150 200 250 300
Span width (cm)
Load, F (kN)
30.00

MQ-124X D
Hilti Pipe Rings

25.00

20.00
Medium duty
System MQ

15.00
HDG

MQ-52-72D

10.00

MQ-41D
Stainless Steel
Medium duty
System MQ

5.00
MQ-21D

0.00
0 25 100 200 300 400 500 600
Span width (cm)

Channel selection table


System MI
HDG

Single span (simply supported)


with single load at mid span, L/2 2.5
3
2.75

2
124
2.5

124

F[kN]
2

82.6

2
72
2
2

52

41.2

2.75
Fixed points

41.3

41.3
System MQ
and sliders

L/2 L/2
31
20.6

41.3 41.3 41.3 41.3 41.3 41.3


L[cm] 41.3 41.3 41.3 41.3

Max. load, F (kN) / deflection, f (mm)

Span width,
L (cm)
25 2 .5 3 <1 4 .6 8 <1 7 .0 8 <1 9 .7 8 0 .2 1 2 .3 6 <1 2 1 .7 5 <1 3 .0 0 <1 6 .0 0 <1 1 1 .2 0 <1
Airconditioning
and Ventilation

System MQ

50 1 .2 7 1 .7 2 .3 5 1 .1 3 .5 6 <1 4 .9 0 0 .9 6 .2 0 <1 1 0 .9 2 <1 3 .0 0 <1 6 .0 0 <1 1 1 .2 0 <1


75 0 .8 2 3 .8 1 .5 6 2 .5 2 .3 7 1 .9 3 .2 6 2 .0 4 .1 3 1 .5 7 .2 7 1 .1 2 .4 2 2 .0 6 .0 0 <1 1 1 .2 0 <1
100 0 .4 5 5 .0 1 .1 7 4 .5 1 .7 7 3 .3 2 .4 4 3 .5 3 .0 9 2 .7 5 .4 5 1 .9 1 .8 1 3 .6 5 .1 9 1 .7 1 1 .2 0 <1
125 0 .2 8 6 .3 0 .8 2 6 .3 1 .4 1 5 .2 1 .9 5 5 .4 2 .4 7 4 .2 4 .3 5 3 .0 1 .4 4 5 .7 4 .1 4 2 .6 1 0 .3 9 1 .8
150 0 .1 9 7 .5 0 .5 7 7 .5 1 .1 7 7 .4 1 .5 4 7 .5 2 .0 5 6 .1 3 .6 2 4 .3 1 .0 9 7 .5 3 .4 4 3 .8 8 .6 5 2 .5
175 0 .1 4 8 .8 0 .4 1 8 .8 0 .8 6 8 .8 1 .1 2 8 .8 1 .7 5 8 .3 3 .0 9 5 .8 0 .7 9 8 .8 2 .9 4 5 .2 7 .3 9 3 .4
Firestop systems

200 0 .1 0 1 0 .0 0 .3 1 1 0 .0 0 .6 5 1 0 .0 0 .8 5 1 0 .0 1 .4 0 1 0 .0 2 .6 9 7 .6 0 .5 9 1 0 .0 2 .5 6 6 .8 6 .4 5 4 .5
225 0 .0 7 1 1 .3 0 .2 3 1 1 .3 0 .5 1 1 1 .3 0 .6 6 1 1 .3 1 .0 9 1 1 .3 2 .3 9 9 .6 0 .4 6 1 1 .3 2 .2 7 8 .6 5 .7 2 5 .7
275 0 .0 5 1 2 .5 0 .1 8 1 2 .5 0 .4 0 1 2 .5 0 .5 2 1 2 .5 0 .8 7 1 2 .5 2 .1 4 1 1 .9 0 .3 6 1 2 .5 2 .0 3 1 0 .6 5 .1 3 7 .0
300 0 .0 4 1 3 .8 0 .1 4 1 3 .8 0 .3 2 1 3 .8 0 .4 2 1 3 .8 0 .7 1 1 3 .8 1 .8 4 1 3 .8 0 .2 8 1 3 .8 1 .8 4 1 2 .8 4 .6 5 8 .5

page 46
Hilti System MQ channel installation
System MQ

Technical data for brackets

and Technical
PC Software

Information
Type of load: uniform Type of load 2: single Type of load 3 Type of load 4 Type of load 5
F1 F1 F2 F2 F3 F3 F3
F1 = q · i 1/
2
1/
2 1/
3
1/
3
1/
3
1/ 1/ 1/ 1/
4 4 4 4

F1 [N] F1 [N] F1 [N] F2 [N] F3 [N]


Channel
Bracket L (mm) HVZ M121) HST M122) HUS 12,53) HVZ M121) HST M122) HUS 12,53) HVZ M121) HST M122) HUS 12,53) HVZ M121) HST M122) HUS 12,53) HVZ M121) HST M122) HUS12,53)
MQK-21/300 300 1050 1050 1050 1050 1050 1050 420 420 420 520 520 520 350 350 350

Medium duty
System MM
Light duty
MQK-21/450 450 500 500 500 700 700 700 180 180 180 310 310 310 190 190 190
MQK-41/300 300 2950 2950 1460 2950 2950 1460 1480 1480 730 1470 1470 730 980 980 480
MQK-41/450 450 1960 1960 970 1960 1960 970 980 980 480 980 980 480 650 650 320
MQK-41/600 600 1470 1470 720 1470 1470 720 620 620 360 730 730 360 490 490 240
MQK-41/1000 1000 580 580 420 840 840 420 210 210 210 360 360 210 220 220 140
MQK-41/3/300 300 4070 3320 1460 4070 3320 1460 2040 1660 730 2030 1660 730 1350 1100 480
MQK-41/3/450 450 2710 2200 970 2710 2200 970 1350 1100 480 1350 1100 480 900 730 320

Medium duty
System MQ
MQK-41/3/600 600 2020 1640 720 2020 1640 720 810 810 360 1010 820 360 670 540 240
MQK-41/600/4 600 1470 1470 1470 1470 1470 1470 620 620 620 730 730 730 490 490 490
MQK-41/1000/4 1000 580 580 580 840 840 840 210 210 210 360 360 360 220 220 220
MQK-72/450 450 6040 3180 1370 6040 3180 1370 3020 1590 680 3020 1590 680 2010 1060 450
MQK-72/600 600 4520 2380 1020 4520 2380 1020 2260 1190 510 2260 1190 510 1500 790 340
MQK-21 D/300 300 3010 3010 1460 3010 3010 1460 1510 1510 730 1500 1500 730 1000 1000 480
MQK-21 D/450 450 2000 2000 970 2000 2000 970 1000 1000 480 1000 1000 480 660 660 320

Hilti Pipe Rings


MQK-21 D/600 600 1490 1490 720 1490 1490 720 570 570 360 740 740 360 490 490 240
MQK-41 D/1000 1000 2560 1400 580 2560 1400 580 1270 700 290 1280 700 290 850 460 190

Technical data for brackets with angle brace


Type of load 1: uniform Type of load 2: uniform Type of load 3 Type of load 4 Type of load 5
F1 F1 F2 F2 F3 F3 F3

Medium duty
F1 = q · I

System MQ
1/2 1/ 1/3 1/3 1/3 1/4 1/4 1/4 1/4
2

HDG
Bracket F1 [N] 1) F1 [N] 1) F1 [N] 1) F2 [N] 1) F3 [N] 1)
L (mm) Brace 5) Bracket 4) HUS 12,5 3) Bracket 4) HUS 12,5 3) Bracket 4) HUS 12,5 3) Bracket 4) HUS 12,5 3) Bracket 4) HUS 12,5 3)
MQK-21/450 450 short 5460 5460 1410 1410 520 520 2440 2440 2130 2030
MQK-41/450 450 short 6390 6110 3960 3960 2750 2750 3190 3050 2130 2030

Stainless Steel
Medium duty
MQK-41/600 600 long 5690 5690 2960 2960 2840 2840 2840 2840 1890 1890

System MQ
MQK-41/1000 1000 long 2250 2250 3400 3400 430 430 1700 1700 1130 1130
MQK-41/3/450 450 short 6380 6110 5450 5450 3190 2960 3190 3050 2120 2030
MQK-41/3/600 600 long 5680 5680 4080 4080 2840 2840 2840 2840 1890 1890
MQK-41/600/4 600 long 5690 5690 2960 2960 2840 2840 2840 2840 1890 1890
MQK-41/1000/4 1000 long 2250 2250 3400 3400 430 430 1700 1700 1130 1130
MQK-72/450 450 short 6380 6100 6380 6100 3190 2960 3190 3050 2120 2030
MQK-72/600 600 long 5680 5680 5680 5680 2840 2840 2840 2840 1890 1890

System MI
MQK-21 D/450 450 short 6380 6110 4040 4040 2810 2810 3190 3050 2120 2030

HDG
MQK-21 D/600 600 long 5680 5680 3030 3030 2840 2840 2840 2840 1890 1890
MQK-21 D/1000 1000 long 3380 3380 3380 3380 1690 1690 1690 1690 1120 1120
1)
Loading capacity of bracket (steel loading capacity) or with HVZ M12 fastening, the loading capacity of the bracket is reached with the HVZ M12.
2)
Loading capacity of bracket fastened with HST M12.
3)
Loading capacity of bracket fastened with HUS H 12.5 or with HST M10 (bending figures for HST M10 taken into account)
4)
Loading capacity of bracket (steel loading capacity) or with HVZ M12 or HST M12 fastening (loading capacity of the bracket is reached with HVZM12/HSTM12)
Fixed points
System MQ

and sliders

5)
Short angle brace: MQK-SK / long angle brace: MQK-SL

Load values are for grade C20/25 concrete.


Alternatively, fastening in solid or hollow brick with HIT HY50 and approval is possible (loading values not given in this table).
The bracket's own weight has been allowed for.
The loads apply only if the bracket is fastened away from a building component edge (fastenings made at component edges must be designed separately).
Separate verification must be provided that forces are transferred to the respective base material, i.e. steel and concrete.
The application guidelines in anchor approvals must be observed. Loading values according to approval status July 2005
Airconditioning
and Ventilation

The deflection (deformation) of L/150 was observed in all cases, this being measured at the point of load application.
System MQ

HVZ adhesive anchor M12 (Hole dia. 14 mm) HST stud anchor M12 (Hole dia. 12 mm) HUS-H screw anchor 12,5 (Hole dia. 10 mm)
Firestop systems

page 4 page 47
System MQ
and Technical
PC Software
Information
Medium duty

System MM
Light duty
Medium duty
System MQ

to approx 20 microns

100 100

2 2
20.6 63x13.5
63x13.5
31
Hilti Pipe Rings

21 3 2 1.438 MQ-21 3 m 369584


22.3
7.5
22.3 7.5
41.3
21 6 2 1.438 MQ-21 6 m 369585 41.3

21 6 2 1.438 MQ-21 6 m 236647*


31 3 2 1.759 MQ-31 3 m 369589 100 100

31 6 2 1.759 MQ-31 6 m 369590


41 3 2 2.080 MQ-41 3 m 369591
2 2.5
63x13.5 63x13.5
41 6 2 2.080 MQ-41 6 m 369592 41.3 52

41 6 2 2.080 MQ-41 6 m 236645* 22.3 7.5


Medium duty

22.3
System MQ

2.942 MQ-52 6 m 369598


7.5
52 6 2.5 41.3
41.3

52 6 2.5 2.942 MQ-52 6 m 430797*


HDG

72 6 2.75 4.101 MQ-72 6 m 369599 100 100

72 6 2.75 4.101 MQ-72 6 m 430801* 2.75 3


41 6 3 2.910 MQ-41/3 6 m 369597 63x13.5
41.3
72
* Please check the availability with Hilti logistic department (available in GCC) 63x13.5 22.3
7.5
Stainless Steel
Medium duty

41.3
Channels and firestop tested
System MQ

22.3
7.5
41.3

IBMB no. 3897/1802-5

75
System MI

75
HDG

41.2
40x13.5

41 6 2 2.904 MQ-21 D 6 m 369602 22.3


7.5
82.6
40x13.5

82 6 2 4.188 MQ-41 D 6 m 369604 41.3

124 6 2.5/2.75 7.078 MQ-52-72 D 6 m 369605 22.3


7.5

124 6 3 9.841 MQ-124X D 6 m 369606


41.3
Fixed points
System MQ
and sliders

75

2.5

124

2.75 40x13.5
Airconditioning
and Ventilation

System MQ

22.3
7.5
41.3

Channels and firestop tested


Firestop systems

124 3

IBMB no. 3897/1802-5


22.3
7.5
41.3

page 48
System MQ

Anchor channel

and Technical
HAC-30

PC Software

Information
The toothed channel designed to fit Hilti installtion systems

Medium duty
System MM
Light duty
Medium duty
System MQ
Applications Technical data
nn Installation of building services in the basement backbone HAC-30
nn Installation of heating, ventilation, A/C, water and other building
Base materials Concrete
services in the building backbones per level
nn Installation of building services in risers Surface Finish Hot dip galvanized 55 µm
For use with HBC-B T-head bolts, Hilti MQ41

Hilti Pipe Rings


nn Floor or ceiling grid systems for applications with advanced
requirements to flexibility and dust or noise reduction e.g. installation system components
semiconductor manufacturing or showrooms Approvals ETA-11/0006 for static-, dynamic
loading and fire
Advantages
nn Toothed channel is compatible with Hilti MQ41 installation
components

Medium duty
nn Increased installation speed for building services vs. traditional

System MQ
anchor fastening

HDG
nn Dust-free and noiseless fastening method
nn Flexibility of use throughout whole building lifecycle

Stainless Steel
Medium duty
System MQ
9 :

Length - L Width - B Height - H Effective embedment Number of Anchor Order designation Sales Item Number
depth anchors distance Quantity

200 mm 42 mm 26 mm 68 mm 2 150 mm Anchor channel HAC-30 68/200 F 1 PC 00431889


250 mm 42 mm 26 mm 68 mm 2 200 mm Anchor channel HAC-30 68/250 F 1 PC 00431890
300 mm 42 mm 26 mm 68 mm 2 250 mm Anchor channel HAC-30 68/300 F 1 PC 00431891

System MI
550 mm 42 mm 26 mm 68 mm 3 250 mm Anchor channel HAC-30 68/550 F 1 PC 00431892

HDG
800 mm 42 mm 26 mm 68 mm 4 250 mm Anchor channel HAC-30 68/800 F 1 PC 00431893
1050 mm 42 mm 26 mm 68 mm 5 250 mm Anchor channel HAC-30 68/1050 F 1 PC 00431894
1300 mm 42 mm 26 mm 68 mm 6 250 mm Anchor channel HAC-30 68/1300 F 1 PC 02026152
1550 mm 42 mm 26 mm 68 mm 7 250 mm Anchor channel HAC-30 68/1550 F 1 PC 02025327
Fixed points

2050 mm 42 mm 26 mm 68 mm 9 250 mm Anchor channel HAC-30 68/2050 F 1 PC 02025328


System MQ

and sliders

2300 mm 42 mm 26 mm 68 mm 10 250 mm Anchor channel HAC-30 68/2300 F 1 PC 00431897


3050 mm 42 mm 26 mm 68 mm 13 250 mm Anchor channel HAC-30 68/3050 F 1 PC 00431898
5800 mm 42 mm 26 mm 68 mm 24 250 mm Anchor channel HAC-30 68/5800 F 1 PC 00431900
Airconditioning
and Ventilation
System MQ

Firestop systems

page 49
System MQ

page 50
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Hilti System MQ channel System MQ
installation

Channel nut

and Technical
PC Software

Information
Features
■ Simple, compact, time saving
■ Single part
■ Easy to use
■ Universal: one and the same nut for all channels
■ Simple removal

Medium duty
System MM
Light duty
Technical data
Galvanising: galvanised, Fe/Zn 13 B

Medium duty
as per DIN 50961

System MQ
Pushbutton
Bolt: M10 material 8.8 as per DIN/ISO898
Width across flats: 17 mm

Hilti Pipe Rings


Nut: QStE 380 TM, SEW 92
Plate: DD11, DIN EN 10111
Connection Weight each Packaging contents Outside packaging contents Ordering Item no.
thread (g) (pcs) (pcs) designation
M10 66 50 300 MQN 369623

Rec. tensile load, Rec. shear load, Tightening torque,

Medium duty
System MQ
Zrec (kN) Qrec (kN) MD (Nm)
Item Channel I Channel II

HDG
MQN 5.0 8.0 5.0 1) 40
Channel I: MQ-21. MQ-31, MQ-41, MQ-21D, MQ-41D
Channel II: MQ-41/3, MQ-52, MQ-72, MQ-52-72D, MQ-124XD IBMB no. 3897/1802-5
1)
Shear loading applies to single fastening. Qrec (kN) 9.0 for two fastenings

Stainless Steel
1 2 3

Medium duty
System MQ
System MI
HDG
Put in position. Press and turn. Tighten.

Wing nut ➀ M6
M8
Fixed points
System MQ

and sliders

Nut, M6–M10: QStE 380 TM, SEW 92 M10


Nut, M12: QStE 32-2 KGK as per DIN 1654
Plastic: PA
Connection Weight each Packaging contents Outside packaging contents Ordering Item no.
thread (g) (pcs) (pcs) designation
M 6 21 50 800 ➀ MQM-M6 369624
M 8 21 50 800 MQM-M8 369698
Airconditioning
and Ventilation


System MQ

M10 21 50 800 ➀ MQM-M10 369626


M12 33 50 800 ➁ MQM-M12 369627 ➁ M12

Rec. tensile load, Rec. shear load, Tightening torque,


Zrec (kN) Qrec (kN) MD (Nm)
Item Channel I Channel II (bolt 8.8)
MQM-M 6 3.0 3.0 1.5 10
Firestop systems

MQM-M 8 5.0 5.0 3.5 20


MQM-M10 5.0 8.0 5.0 40
MQM-M12 5.0 8.0 5.0 40
Channel I: MQ-21, MQ-31, MQ-41, MQ-21D, MQ-41D
Channel II: MQ-41/3, MQ-52, MQ-72, MQ-52-72D, MQ-124XD

page
page51
7
System MQ

page 52
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Hilti System MQ channel installation System MQ

Angles, angle brackets,


connectors

and Technical
PC Software

Information
Features
Universal: few parts for all applications 19.4 19

Easy to use
Three-dimensional, thus high strength
35 10

Medium duty
System MM
Light duty
Technical data
Material: S 235 J R as per DIN EN 10 025
Material thickness 4 mm
Galvanising: galvanised, Fe/Zn 13 B

Medium duty
as per DIN 50961

System MQ
MQW-Q2 pre-assembled 90° angle
56
Features

Hilti Pipe Rings


Pre-assembled for rapid installation
Reliable keying action 56
High strength

Technical data
Tightening torque: 40 Nm
Material thickness: 3 mm

Medium duty
Bolt: M10 material 8.8 as per DIN/ISO 898

System MQ
Frec 4.0 kN Frec 3.0 kN
Width across flats: 17 mm

HDG
Weight each Packaging ) Ordering Item no.
(g) contents (pcs) designation
90° angle 200 20 MQW-Q2 369655

Stainless Steel
Medium duty
1 2

System MQ
System MI
HDG
Pres s and turn. Tighten. Fixed points
System MQ

and sliders
Airconditioning
and Ventilation
System MQ

Firestop systems

page 10
page 53
System MQ Hilti System MQ channel installation

90 º angle ➀ Frec 5.0 kN Frec 3.7 kN


and Technical
PC Software
Information

Weight each Packaging Ordering Item no.


(g) contents (pcs) designation
Angle, 4 hole, 90° 220 10 ➀ MQW-4 369658 55
Angle, 8 hole, 90° 420 10 ➁ MQW-8/90° 369659
Angle, 3 hole, 90° 160 20 ➂ MQW-3 369656
Angle, 2 hole, 90° 160 10 ➃ MQW-P2 369661

Medium duty

System MM

Frec 9.0 kN Frec 5.0 kN


Light duty

105
Medium duty
System MQ

➂ Frec 6.8 kN Frec 2.5 kN

61
111
Hilti Pipe Rings

➃ 46
Medium duty
System MQ

46
HDG

45 º angle ➀
Frec 9.0 kN Frec 5.0 kN
105
Stainless Steel
Medium duty
System MQ

45°
Weight each Packaging Ordering Item no.
(g) contents (pcs) designation
Angle, 8 hole, 45° 410 10 ➀ MQW-8/45° 369660
Angle, 3 hole, 45° 155 20 ➁ MQW-3/45° 369657
Angle, 2 hole, 45°, inner 354 10 ➂ MQW-2/45° 369662

Frec 7.0 kN Frec 2.5 kN
106
System MI

45°
HDG

56


Fixed points
System MQ
and sliders

100
Frec 3.0 kN Frec 1.1 kN

45°

100
Airconditioning
and Ventilation

System MQ

135 º angle
Frec 4.5 kN Frec 3.0 kN
85
Weight each Packaging Ordering Item no. 45°
(g) contents (pcs) designation
Angle, 3 hole, 135° 210 10 MQW-3/135° 369663
Firestop systems

55

page 54 page 11
page 55
System MQ

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
System MQ

page 56
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Hilti System MQ channel installation System MQ

Channel base / Base material


connector

and Technical
PC Software

Information
Features
Reliable and easy to use 19.4 19

Connection of channels to any base material


35 10

Medium duty
System MM
Light duty
Technical data
M at er i al : S 2 3 5 JR as p er DI N EN 10 0 2 5
Galvanising: galvanised Fe/Zn 13 B
as per DIN 50961
Separate design verification of the fastening on the base material must
be provided.

Medium duty
System MQ
Base material connector 167

112

Frec 9.0 kN
Su i t ab l e f o r W ei g h t each Packag i n g Or d er i n g I t em n o .

Hilti Pipe Rings


ch an n el ( g) co n t en t s ( p cs) d esi g n at i o n Frec 5.0 kN
MQ-41, MQ-41/3, MQ-21D 438 10 MQV-2/2D-14 369639
112

MQ-21, MQ-31, MQ-41, MQ-41/3 110 20 MQP-1/1 369646


MQ-21, MQ-31, MQ-41, MQ-41/3 190 20 MQP-1/3 369647
MQ-21, MQ-31, MQ-41, MQ-41/3 290 10 MQP-2/3 369648
MQ-21, MQ-31, MQ-41, MQ-41/3 135 10 MQP-2/1 377731

Frec Channel Bolt Pushbutton Tightening torque,

Medium duty
System MQ
I t em ( k N) ( B) ( A) M D (Nm)
MQV-2/2D-14 7.8 MQ-41 Double MQN 40

HDG
18x12

8.4 MQ-21D Quadruple MQN 40


3x
14x19

59
61 80
118
61 40

Stainless Steel
Medium duty
System MQ
60 52 32
5

11,5 x 30
44

54
59

11.5 34

System MI
HDG
Base material connector 45 º
Fo r W ei g h t each Packag i n g Or d er i n g I t em n o . Frec 7.0 kN Frec 5.0 kN
ch an n el ( g) co n t en t s ( p cs) d esi g n at i o n
MQ-21, MQ-31, MQ-41, MQ-41/3 350 10 MQP-45° 369649 105
Fixed points
System MQ

and sliders

45° 40x40x4

14

41 42
Airconditioning
and Ventilation
System MQ

Firestop systems

page 14 page 57
System MQ Hilti System
Hilti System MQ
MQ channel
channel installation
installation

Channel base ➀
A
A
and Technical
PC Software
Information

105
105
Suitable for Weight each Packaging Ordering no.
Item no.
channel (g) contents (pcs) designation
20x14
20x14

MQ-21–MQ-72 1150 12 ➀ MQP-21-72 369651 66


FFrec
rec
MQ-41D 1880 8 ➁ MQP-82 369652 80
80
135
135

MQ-52-72D, MQ-124X D 2730 6 ➂ MQP-124 369653


185
185


Frec Bolt Pushbutton Tightening torque, AA AA
Item (kN) (A) MDD (Nm)
Medium duty

System MM
Light duty

106
106

MQP-21-72 9.0 Double MQN 40


FFrec
20x14
20x14
rec
MQP-82 12.6 Quadruple MQN 40 88

MQP-124 12.6 Quadruple MQN 40 100


100
150
150
200
200

Channel base  firestop tested ➂


AA AA
130
130
Medium duty
System MQ

20x14
20x14
FFrec
rec
88

200
200
250
250
100
IBMB no. 3897/1802-5
100

Pivot base
Hilti Pipe Rings

Suitable for Weight each Packaging Ordering Item no.


no. 152
152

channel (g) contents (pcs) designation


MQ-21, MQ-31, MQ-41, MQ-41/3 1055 10 MQP-G 369654
49
49

Frec Bolt Pushbutton Tightening torque, 75


75
Item (kN) MDD (Nm) 75
75 190
190
54
54

9.0 Double MQN 40


Medium duty

MQP-G
System MQ
HDG

Adjustable pivot base MQP-FG FFrec


rec (1)
(1)

Suitable for Weight each Packaging Ordering Item no.


no.
Stainless Steel

channel (g) contents (pcs) designation


Medium duty
System MQ

MQ-21, MQ-31, MQ-41, MQ-41/3, MQ-21D 2070 4 MQP-FG 284240 aa

215
215
Item Frec (1) (kN) Bolt Push- Tightening torque MQN Tightening torque M12
M12 FFrec
rec (2)
(2)
button MD (Nm) clamping bolts MDD (Nm)
(Nm)
MQP-FG 8 kN Double MQN 40 80

129
129
System MI

90
90
Load Frec (2) [kN] M12
M12
HDG

2.50 44
44
20x13.5
20x13.5

44 120
120
2.00 59
59 180
180
Fixed points
System MQ
and sliders

1.50

1,00
Airconditioning
and Ventilation

System MQ

0.50

0.00
0.00
00 50
50 100
100 150
150 200
200 250
250 300
300 350
350 400
400
Firestop systems

Distance
Distance to
to the
the pivot
pivot point:
point: aa [mm]
[mm]

page 58 page
page 15
15
Hilti System MQ channel
channel installation
installation System MQ

Beam clamp

and Technical
PC Software

Information
Features
■ For connecting installation
installation channels
channels to
to steel
steelbeams
beamswithout
withoutdrilling
drilling
or welding
■ The clamp set fits all standard
standard T-beams
T-beams

Medium duty
System MM
Light duty
Technical data
Material:
U-bolt: SS 235
235 JRG-2
JRG-2as
asper
perDIN
DINEN
EN10025
10025
Claw plate: SS 235
235 JR
JRas
asper
perDIN
DINEN
EN10025
10025
Nut: as
as per
per DIN
DIN934
9348-A2K
8-A2K
Galvanising:
Galvanising: galvanised
galvanisedFe/ZN
Fe/ZN1313BB

Medium duty
as
as per
per DIN
DIN50961

System MQ
50961

Beam clamp ➀

➀ ➁
➁➁
M8
M8 M10
M10
M8 M10
Suitable for
Suitable for Weight
Weighteach
Weight each
each Packaging
Packaging
Packaging Ordering
Ordering
Ordering Item
Itemno.
Item no.
no.

Hilti Pipe Rings


channel
channel (g)
(g)
(g) contents
contents(pcs)
contents (pcs)
(pcs) designation
designation
designation
92
9292 55
92
9292 66
6
5
MQ-21, MQ-31,
MQ-21, MQ-31, MQ-41,
MQ-41, MQ-21D
MQ-21D 500
500 10
10 ➀ MQT-21-41
➀ MQT-21-41 369675
369675
369675
60
6060
95
9595
140

MQ-41, MQ-41/3, MQ-52,


MQ-41, MQ-41/3, MQ-52, MQ-72,
MQ-72, MQ-41D 650 10 ➁ MQT-41-82 369676 9090 140
369676
90
MQ-41D 650 10 ➁ MQT-41-82 369676
140

MQ-41D, MQ-52-72D,
MQ-41D, MQ-52-72D, MQ-124X
MQ-124X DD 860
860 10
10 ➂ MQT-82-124
➂ MQT-82-124 369677
369677
369677

Tightening torque, Max.


Max. rec. load ➂


Tightening torque, Max.rec.
rec.load
load
Beam clamp MDDD(Nm) (kN)
(kN)
Beam clamp M (Nm) (kN) M12
M12
M12
MQT-21-41 10 3.0

Medium duty
MQT-21-41 10 3.0

System MQ
92 88
MQT-41-82 20 4.5
92
92 8
MQT-41-82 20 4.5

HDG
85
85
85
MQT-82-124
MQT-82-124 30
30 5.0
5.0 178
Always use beam clamps in pairs.
178
178
Always use beam clamps in pairs.
Channel loading
Channel loading values
values must
must be
be allowed
allowed for.
for.

Stainless Steel
Medium duty
System MQ
Beam Clamp
Beam Clamp
Advantages
Advantages
■ For connecting installation channels to steel beams without drilling
■ For connecting installation channels to steel beams without drilling
or welding
or welding
■ The beam clamp fits all standard T-beams
■ The beam clamp fits all standard T-beams
(flange thickness ≤ 30 mm)

System MI
(flange thickness ≤ 30 mm)
■ Massive design

HDG
■ Massive design
■ Shear loading possible
■ Shear loading possible

Technical Data
Technical Data
Material clamb: EN-GJMB-350-10 (DIN EN 1562)
Material clamb: EN-GJMB-350-10 (DIN EN 1562)
Material screw: M12 steel 8,8-A2K (DIN 933)
Fixed points
System MQ

Material screw: M12 steel 8,8-A2K (DIN 933)


and sliders

Galvanising: galvanised, Fe/Zn 13 B


Galvanising: galvanised, Fe/Zn
As per DIN 50 961 13 B
As per DIN 50 961

Beam Clamp MQT 68.5 48


68.5 48
Beam Clamp MQT 68.5 48
Airconditioning
and Ventilation

M12x50
M12x50
For
For channel
channel Weight/pc.
Weight/pc. Packaging
Packaging Ordering
Ordering Item
Item no.
no.
System MQ

M12x50
For channel Weight/pc.
(kg)
(kg) Packaging
(pcs)
(pcs) Ordering
designation
designation Item no.
(kg) (pcs) designation
MQ-21D, MQ-41, MQ-41/3 0.716 16 MQT 41 286107
286107 FFy
y
104.6
104.6
MQ-21D, MQ-41, MQ-41/3 0.716 16 MQT 41 286107 Fy
104.6

item
item Max.
Max. rec.
rec. load
load per
per pair
pair Thightening
Thightening torque
torque
item Fz
Fz (kN)
Max. rec. load perFx
(kN) (kN)
pair
Fx (kN) M
M DD (Nm)
Thightening
(Nm) torque
Fz (kN) Fx (kN) M D (Nm)
MQT41 20 9 20 FFx
MQT41 20 9 20
Firestop systems

52
52
x
Always use beam clamps in pairs. Channel loading values must be respected. Fx 52
Always use beam
Load values do notclamps in pairs.
apply on Channel
cantilever loading
channel values must be respected.
endings. FFz
z
Load values do not apply on cantilever channel endings. Fz

page
page 16
16
page 59
page 16
System MQ Hilti System
Hilti SystemMQ
MQchannel
channelinstallation
installation

Beam clamp MAB


and Technical
PC Software

galvanised, 5 µm
Information

Features
■ Installation on steel beams without drilling or welding.
■ Through hole «Y» without thread.
■ Height adjustment possible, especially after fitting by loosening
loosening
the locknuts.
Medium duty

System MM
Light duty

Technical data
VdS: Above pipe size DN 65,
retaining straps are required !
Medium duty
System MQ

VdS
VdS R
R
FM
FM
Factory
FactoryMutual
Mutual
Hilti Pipe Rings

Size
Size Approval
Approval Dimensions
Dimensions [mm]
[mm] Packaging
Packaging Outside
Outsidepackaging
packaging Ordering
Ordering Item
Itemno.
no.
TT U
U VV W
W XX YY ZZ contents
contents contents
contents designation
designation
M8
M8 VdS
VdS 34.5
34.5 36.1
36.1 18.5
18.5 18
18 20.9
20.9 99 M8
M8 12
12 192
192 ➀
➀ MAB-9
MAB-9 375956
375956
M10
M10 VdS/FM/UL
VdS/FM/UL 41
41 41.8
41.8 21
21 19.5
19.5 23.4
23.4 11
11 M10
M10 12
12 96
96 ➀
➀ MAB-11
MAB-11 375957
375957
M12
M12 VdS/FM/UL
VdS/FM/UL 48
48 54
54 23.5
23.5 26
26 35
35 13
13 M10
M10 12
12 96
96 ➁
➁ MAB-13
MAB-13 375958
375958
M16
M16 VdS/FM/UL
VdS/FM/UL 55.5
55.5 58
58 29.5
29.5 28.5
28.5 30
30 17
17 M12
M12 12
12 48
48 ➁
➁ MAB-17
MAB-17 228155
228155

➀ ➁
Medium duty

➀B ➁
System MQ

AA YY AA YY
B BB
ZZ
HDG

TT ZZ TT

W W
W W
V V
V V
X U U
X U X U
X
Stainless Steel
Medium duty
System MQ

Pipe size DN according to Tightening torque Tightening torque


Pipe size DN according to Tightening torque Tightening torque
Type VdS UL FM Frec. Weight locking screw locknut
Type VdS UL FM Frec.
[N]
Weight
[g]
locking screw
MD [Nm]
locknut
MD [Nm]
[N] [g] MD [Nm] MD [Nm]
MAB-9
MAB-9 ≤ 50
≤ 50 –– –– 1200
1200 81
81
MAB-11 > 50 100 100 Tightening
Tightening by
by Tightening
Tightening by
by
MAB-11 ≤
> 50 ≤ 100 ≤≤ 100 ≤≤ 100
100 2500
2500 143
143 hand + 1
1⁄2 turn with hand + 1
⁄18 turn with
MAB-13 > 100 150 > 100 200 > hand + ⁄2 turn with hand + ⁄8 turn with
≤ ≤ > 100
100 ≤≤ 200 3500 216
System MI

MAB-13 > 100 ≤ 150 > 100 ≤ 200 2001) 3500 216 wrench
wrench wrench
wrench
MAB-17 >> 150
150 ≤
≤ 200 >> 200 ≤ 300
200 ≤ 300 >> 200200 ≤≤ 300 5500 318
HDG

MAB-17 200 300 1) 5500 318


Loading: In
Loading: In accordance
accordance with
with the
the VdS,
VdS, UL
UL and
and FM
FM specifications
specifications
1) Only when the direction of tension is toward the web.
1) Only when the direction of tension is toward the web.

VdS
VdS and
and UL
UL application
application overview FM
FMapplication
applicationoverview
Fixed points
System MQ
and sliders

overview overview
Straight flange
Straight flange Inclined
Inclined flange
flange Straight
Straightflange
flange Inclined
Inclinedflange
flange
1)
1)
Airconditioning
and Ventilation

System MQ

1) 1)
1) 1)

1) FM approved in this application only up to DN 200


Firestop systems

1) FM approved in this application only up to DN 200

page 17
page 60 page 17
Frec. Frec.

Hilti System MQ channel installation System MQ

Retaining joint
Universal straps for beam clamps
MQP-U

and Technical
PC Software

Information
glavanised, 5 µm
Features:
For clamp Approval Dimensions [mm] Packaging Outside packaging Ordering Item no.
■ Universal fastening on inclined
L components.
B l1 l2 d1 d2 contents (pcs) contents designation
MAB-11/-13 VdS 350 25 14.8 19
■ Direct connection on the building structure and on installation 10.5 12.5 12 120 MAB-S 11/ 13 374409
MAB-17 VdS 400 40 14.5 22 12.5 17 12 48 MAB-S 17 228156
channels, especially suitable for bracings.
■ Angle stepless fixable up to 90°. l2
Installation instruction: retaining strap

Medium duty
■ Easy handling and height adjustment of the threaded rod.

System MM
3

Light duty
L
d2

Technical data:
Material: S235 JRG-2 as per DIN EN 10025 l1

Material thickness: 5 mm d1
B
Galvanising: galvanised, Fe / Zn 13 B
as per DIN 50961

Medium duty
System MQ
Separate design verification
F of the fastening on the base
rec. Frec. material or other

installation components must be provided.

Universal
Universal joint
joint MQP-U
MQP-U

Hilti Pipe Rings


Features:
Size D1 D2 Weight Packaging Ordering Item no.
■ Universal fastening
(mm) on inclined
(mm) components.
each (g) contents (pcs) designation
M12 12.5 on the12.5
■ Direct connection 390 and on 10
building structure installation MQP-U M12 284248
16.5
M16channels, especially 16.5 for bracings.
suitable 390 10 MQP-U M16 284249
■ Angle stepless fixable up to 90°.

Medium duty
System MQ
ItemEasy handling and height adjustment
■ of the threaded rod.
Max. rec. load Tightening torque MD
(kN) (Nm)

HDG
MQP-U M12 14 20
Technical
MQP-U M16 data: 14 20
Material: S235 JRG-2 as per DIN EN 10025
Material thickness: 5 mm
Technical data for fastening the MQP-U
Galvanising: universal
galvanised, Fe joint
/ Zn 13 to BMQ channels

Stainless Steel
Medium duty
as per DIN 50961

System MQ
Separate
Angle design verification of the fastening
Max. recommended load Frec (kN)on the Tightening
base material
torque or other FF
empf
rec
Channel I Channel II MD (Nm)
installation components must be provided.
90° 5.0 8.0 20 Winkel
variable
60° 4.0 8.0 20 variabel
angle
30° 3.0 5.0 20
0° 3.0 5.0 20
Universal joint MQP-U
Channel I: MQ-21, MQ-31, MQ-41, MQ-21D, MQ-41D

System MI
Channel II: MQ-41/3, MQ-52, MQ-72, MQ-52-72 D, MQ-124XD

HDG
Interim valuesD1of the angleD2can be interpolated
Size Weight
linearly.
Packaging Ordering Item no.
(mm) (mm) each (g) contents (pcs) designation
M12 12.5 12.5 390 10 MQP-U M12 284248
page 18
M16 16.5 16.5 390 10 MQP-U M16 284249
Fixed points
System MQ

and sliders

Item Max. rec. load Tightening torque MD


(kN) (Nm)
MQP-U M12 14 20
MQP-U M16 14 20

Technical data for fastening the MQP-U universal joint to MQ channels


Airconditioning
and Ventilation
System MQ

Angle Max. recommended load Frec (kN) Tightening torque FF


Channel I Channel II MD (Nm) empf
rec

90° 5.0 8.0 20 Winkel


variable
60° 4.0 8.0 20 variabel
angle
30° 3.0 5.0 20
Firestop systems

0° 3.0 5.0 20
Channel I: MQ-21, MQ-31, MQ-41, MQ-21D, MQ-41D
Channel II: MQ-41/3, MQ-52, MQ-72, MQ-52-72 D, MQ-124XD
Interim values of the angle can be interpolated linearly.

page 18
page 61
System MQ Hilti System
Hilti System MQ
MQ channel
channel installation
installation

Beam clamps MQT


and Technical
PC Software
Information

Features:
■ For connecting installation channels to steel beams without drilling
or welding.
■ The clamp set fits all standard T-beams
(max. clamping thickness ≤ 36 mm).

Technical data:
Medium duty

System MM
Light duty

Material: GJMW400-5
Galvanising: galvanised Fe/Zn 13 B
as per DIN 50961
Delivery without wing nut, nut, boss plate, washer and bolt.
Medium duty
System MQ

Beam clamps MQT GG AA


Size Dimensions Weight
Weight Packaging
Packaging Ordering
Ordering Item
Item no.
no.
Hilti Pipe Rings

(mm) each
each contents
contents designation
designation
B T A G (g)
(g) (pcs)
(pcs)
M10 52 68 30 23×11 160 20 MQT-M10
MQT-M10 284242
284242 BB
TT
M12 52 74 32 29×13 190 20 MQT-M12
MQT-M12 284243
284243
M16 52 75 36 32×17 215 10 MQT-M16
MQT-M16 284244
284244

Application case 
Suitable for: MQ-21, MQ-31, MQ-41, MQ-41/3, MQ-52, MQ-72, MQ-21D, MQ-41D,
MQ-41D, MQ-52-72D
MQ-52-72D
Medium duty
System MQ
HDG

Item Rec. tensile load (kN) Tightening


Tightening torque
torque Necessary
Necessary bolt
bolt length
length CC
Channel I Channel II M
MDD (Nm)
(Nm) LL (mm)
(mm)
MQT-M10 10.0 10.0 40
LL == 60
60 mm
mm ++ DD ++ CC
MQT-M12 10.0 15.0 40
Channel I: MQ-21, MQ-31, MQ-41, MQ-21D, MQ-41D DD
Channel II: MQ-41/3, MQ-52, MQ-72, MQ-52-72 D
Stainless Steel
Medium duty

Always use beam clamps in pairs.


System MQ

Channel loading values must be allowed for. FFrec


rec
The load values do not apply for cantilever channel endings.

Application case 
Suitable for: MQ-21, MQ-31, MQ-41, MQ-41/3, MQ-52, MQ-72, MQ-21D, MQ-41D,
MQ-41D, MQ-52-72D,
MQ-52-72D,
System MI

MQ-124XD
HDG

Item
Item Rec.
Rec. tensile
tensile load
load (kN)
(kN) Tightening
Tightening torque
torque Necessary
Necessary bolt
bolt length
length
Channel
Channel II Channel
Channel IIII M
MDD (Nm)
(Nm) LL (mm)
(mm)
MQT-M10 10.0 10.0 40
LL == 41
41++ 0.6
0.6 xx DD
MQT-M12 10.0 15.0 40 DD

Channel I: MQ-21, MQ-31, MQ-41, MQ-21D, MQ-41D


Channel II: MQ-41/3, MQ-52, MQ-72, MQ-52-72 D, MQ-124X D
Fixed points
System MQ
and sliders

Always use beam clamps in pairs. FFrec


rec
Channel loading values must be allowed for.
The
The load
load values
values do
do not
not apply
apply for
for cantilever
cantilever channel
channel endings.
endings.

Application case 
Application case
Airconditioning
and Ventilation

System MQ

Suitable
Suitable for: Connection
for: Connection of
of steel-plates
steel-plates
Item
Item Rec.
Rec. tensile
tensile load
load (kN)
(kN) Tightening
Tightening torque
torque Necessary
Necessary bolt
bolt length
length
M
MDD (Nm)
(Nm) LL (mm)
(mm)
MQT-M10
MQT-M10 10.0
10.0 50
50
MQT-M12
MQT-M12 15.0
15.0 80
80 LL == 60
60 mm
mm ++ DD ++ PP
MQT-M16 20.0 120
Firestop systems

MQT-M16 20.0 120


Always use four clamps.
Always use four clamps.
Steel-plate
Steel-plate must
must be
be separately
separately verified.
verified. DD
PP
FFrec
rec

page
page 19
page 62 19
System MQ
Hilti System MQ channel
channel installation
installation System MQ

clamp MQT-G
Swivel beam clamp MQT-G

and Technical
PC Software
galvanised, 13 µm

Information
M
MMDDD

TTT
Features
■ Installation on steel beams
beams without
without drilling
drilling or
or welding,
welding,also
also
on inclined steel beams.
beams.
■ No bending of threaded
threaded rods.
rods.

Medium duty
System MM
W
WW111

Light duty
■ The clamp set fits all standard UUU
standard T-beams
T-beams (max.
(max. clamping
clamping
thickness ≤ 17 mm). W
WW222

XXX
Technical data
VdS: Above
Above pipe
pipe size
size DN
DN 65,
65,retaining
retainingstraps
strapsare
are
required!
required! GGG

Medium duty
System MQ
VdS: For
For the
the applications
applications 111 and
and 444 retaining
retainingstraps
straps FFrec
Frec
rec
are
are required!
required!

For
ForVdS-approved
VdS-approved
VdS-approved
FM
FM
Item FFrec
rec (kN) FFrec
rec(kN) Thightening
Thighteningtorque
FM
(kN) (kN) Thightening torque
torque

VdS
rec rec

VdS
(≤
(≤25°)
25°) (>
(>25°)25°) MDDD(Nm)
M
M (Nm)
(Nm) installation
installationsee
installation see
see
MQT-G M8: 2,5 1,5
1,5 18
18 www.hilti.com/
www.hilti.com/
www.hilti.com/

Hilti Pipe Rings


vds-installation Factory
FactoryMutual
Factory Mutual
Mutual
MQT-G M10: 2,5 1,5 18 vds-installation
vds-installation
1,5 18
Loading: VdS
VdSGGG402
4021003
Loading: In
In accordance
accordance with
with the
the VdS
VdS and
andFM
FMspecifications
specifications VdS 402 1003
1003

Size
Size Approval
Approval Dimensions
Dimensions [mm]
[mm] Weight
Weight
Weight Packaging
Packaging
Packaging Outside
Outsidepackaging
Outside packaging
packaging Ordering
Ordering
Ordering Item
Itemno.
Item no.
no.
TT UU W1
W1
W1 W2
W2
W2 XXX each
each(g)
each (g)
(g) contents
contents(pcs)
contents (pcs)
(pcs) contents
contents(pcs)
contents (pcs)
(pcs) designation
designation
designation

Medium duty
M8 VdS 53 58 17 55 27 266
266 20
20 40
40 MQT-G
MQT-GM8
M8 284238

System MQ
53 58 17 55 27 266 20 40 MQT-G M8 284238
284238
M10 VdS / FM 53
53 58
58 17
17 55
55 27
27 266
266
266 20
20
20 40
40
40 MQT-G
MQT-GM10
MQT-G M10 284239
M10 284239
284239

HDG
Retaining strap for
for swivel
swivel beam
beam clamp
clamp
MQT-G

Stainless Steel
Medium duty
System MQ
For
For swivel
swivel beam
beam clamp
clamp Dimensions
Dimensions [mm]
[mm] Packaging
Packaging
Packaging Ordering
Ordering
Ordering Item
Itemno.
Item no.
no.
Lenght
Lenght Width
Width Thickness
Thickness
Thickness contents
contents(pcs)
contents (pcs)
(pcs) designation
designation
designation
MQT-G
MQT-G M8,
M8, MQT-G
MQT-G M10
M10 305
305 40
40 33 10
10 MQT-S
MQT-S
MQT-S 284863
284863
284863

VdS
VdS and
and FM
FM approved
approved applications
applications Non-VdS
Non-VdSand
Non-VdS andFM
and FMapproved
FM approvedapplications
approved applications
applications

System MI
HDG
11 22 33 444 555 666 777

90°
90°
90°
Fixed points
System MQ

and sliders

≥≥25° Max.
Max. 45°
≥≥ 25° ≥25°
25°
≥≥25°
≥25° Max. 45° Max.45°
45°
≥ 25°
25° 25° Max.
Max.45°
45°

Installation
Installation instruction:
instruction: swivel
swivel beam
beam clamp
clamp Installation
Installationinstruction:
Installation instruction:retaining
instruction: retainingstrap
retaining strap
strap
Airconditioning
and Ventilation
System MQ

Firestop systems

page 20 page 63
page
page 20
20
System MQ Hilti System MQ channel installation

Clamping bracket MQT-K


and Technical
PC Software
Information

Features:
■ For connecting installation channels to steel beams without drilling
or welding.
■ The clamp set fits all standard double T-beams and U-beams.
■ Easy installation of pipes on steel beams.
Medium duty

System MM
Light duty

Technical data:
Material: S235 JRG-2 as per DIN EN 10025
Material thickness: 5 mm
Galvanising: galvanised, Fe/Zn 13 B
as per DIN 50961
Medium duty
System MQ

Clamping bracket MQT-K 60

Consisting of 2 clamping plates.


Hilti Pipe Rings

Suitable Weight / set Packaging contents Ordering Item no.


for channel (g) (set) designation
MQ-41, MQ-41/3 720 5 MQT-K 284241

Item Tightening torque For beam flange widths Cut length L of the
MD (Nm) B (mm) channel section (mm)
MQT-K 30 100 to 400 mm L = B – 25 mm
Medium duty
System MQ
HDG

Load, Frec [kN]


4.00
Stainless Steel
Medium duty
System MQ

3.50

3.00

2.50
System MI
HDG

2.00

1.50
a
Fixed points
System MQ
and sliders

1.00

0.50
Airconditioning
and Ventilation

System MQ

rec

0.00
0 50 100 150 200 250 300 350 400
Distance a [mm]

The design of the clamped channel and the steel beam must be separately verified.
The permissible bending moment of the threaded rod must be noted.
Firestop systems

page 64 page 21
page 65
System MQ

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
System MQ Hilti System MQ channel installation

3D system
and Technical
PC Software
Information

Features
■ Universal: few parts for all applications
■ For installation of angles or connectors on site 19.4 19

■ Quick and easy to use


■ 45° angle and bracing with predetermined bending point
35 10

Technical data
Medium duty

System MM
Light duty

Material: ➀ + ➂: QStE 380 TM as per SEW 092


➁ + ➃: DD11 as per DIN EN 10111
Material thickness 3 mm
Galvanising: galvanised Fe/Zn 13 B
as per DIN 50961
Bolt: M10 material 8.8 as per DIN/ISO 898
Medium duty

Width across flats: 17 mm


System MQ

Tigthening torque: 40 Nm

3D system ➀ 90
Supported at both ends
Hilti Pipe Rings

Description Weight each Packaging contents Ordering Item no. Frec = 2.5 kN
(g) (pcs) designation
Basic unit 206 20 ➀ MQ3D-B 369694
90° angle 212 20 ➁ MQ3D-W90° 369695 Frec ≤ Qrec MQN
with MQ3D-B
45° angle 153 16 ➂ MQ3D-W45° 369696
Brace 95 20 ➃ MQ3D-A 369697 21.5

Tension/compression bracing

61 Frec = 2.5 kN
Example of application
Medium duty
System MQ

Variable angle

ds
en
th
bo
HDG

at
Frec ≤ Qrec MQN

d
te
or
pp
with MQ3D-B

Su
26
Directly on channel
Stainless Steel

Frec ≤ Qrec MQM-M10


Medium duty

fastened to channel with


System MQ

➂ MQZ-L11 boss plate


M10x20-8.8 hex. screw
MQM-M10 wing nut Frec = 2.5 kN
50
Variable angle

45°

30
System MI

Tension bracing
HDG

➃ Frec = 2.5 kN

Frec ≤ Qrec MQN


with MQ3D-B Variable
angle
50
45°
Fixed points
System MQ
and sliders

25 Directly on channel
Frec ≤ Qrec MQM-M10
fastened to channel with
MQZ-L11 boss plate
M10x20-8.8 hex. screw Frec = 2.5 kN
MQM-M10 wing nut
Variable angle
Airconditioning
and Ventilation

System MQ

Note
The preassembled fastening screw must be replaced
with a longer 8.8 grade M10 screw when the con-
necting parts (MQ3D-W90°, MQ3D-W45°, MQ3D-
A) are fitted without other parts from the 3D system.
Firestop systems

The minimum thread engagement lengths must be


observed.

page 66 page 25
System MQ

Angle

and Technical
MP-MQE-W

PC Software

Information
Medium duty
System MM
Light duty
Medium duty
System MQ
Applications Technical data
nn 90° connection of MQ channels
MP-MQE-W
nn Universal: few parts for a wide range of applications
Material composition S235JR as per DIN EN 10025
nn Medium-duty load range
Surface Finish Galvanized

Hilti Pipe Rings


Additional product information Use with 2pc. wing nuts
Advantages MQM-M10 and 2pc. bolts
nn Reliable and easy to use M10x25 grade 8.8
nn Quick installation without welding
nn Pre-galvanized

Medium duty
System MQ
1 2
)UHF N1 )UHF N1 

HDG
 






Stainless Steel
Medium duty
System MQ
3
)UHF N1 )UHF N1

System MI


HDG


Fixed points
System MQ

and sliders


Airconditioning
and Ventilation

Order designation Weight Thickness Tightening torque Sales Quantity Item Number
System MQ

1 2-hole angle MP-MQE-W2 94 g 3 mm 40 Nm 20 PC 02022804


2 2-hole angle MP-MQE-WP2 113 g 4 mm 40 Nm 10 PC 02022805
3 4-hole angle MP-MQE-W4 324 g 4 mm 40 Nm 10 PC 02022806
Firestop systems

page 67
System MQ

Rail support
and Technical

MP-MQE-P
PC Software
Information
Medium duty

System MM
Light duty

Applications Technical data


Medium duty

nn Connection of MQ channels to any base material


System MQ

MP-MQE-P
nn Medium- to heavy-duty load range
Material composition S235JR as per DIN EN 10025
Surface Finish Galvanized
Advantages
Additional product information Use with 2pc. wing nuts MQM-
nn Reliable and easy to use M10 and 2pc. bolts M10x25
nn Quick installation without welding grade 8.8
Hilti Pipe Rings

nn Pre-galvanized



$
Medium duty
System MQ
HDG



[



Stainless Steel

)UHF

N1
Medium duty
System MQ



Order designation Weight Thickness Tightening torque Sales Quantity Item Number

Rail support MP-MQE-P-21-72 979 g 4 mm 40 Nm 12 PC 02022807


System MI
HDG
Fixed points
System MQ
and sliders
Airconditioning
and Ventilation

System MQ
Firestop systems

page 68
System MQ
Hilti System MQ channel installation

MQP-E-N elevator wall base

and Technical
PC Software

Information
Applications
■ Elevator door fastening support

Advantages
■ Easy, secure attachment of installation channels with pushbuttons

Medium duty
■ Quick installation of the wall base on any base material

System MM
Light duty
■ Elongated holes for flexible positioning to avoid rebar hits
■ Various channel lengths for great versatility
■ Flexible position of the wall base

Technical data

Medium duty
System MQ
Material: S235JR according to DIN EN 10025
Galvanizing: galvanized, Fe/Zn 13B as per DIN 50 961
62

Hilti Pipe Rings


Ordering designation Package contents Weight Item no.
MQP-E-N elevator wall base 2 1.000g 387734 189

1442 mm (max. ; case 1)


205

Medium duty
1642 mm (max. ; case 2)

System MQ

HDG
Loading scenario
Type of load recommended load F recommended load F
Channel MQ-21D
for L = 1642 mm for L = 1442 mm
F
Channel position
0.90 kN 1.18 kN L

Stainless Steel
Medium duty
System MQ
F F

0.52 kN 0.69 kN
F F F

0.39 kN 0.49 kN
F 1.05 m F

0.88 kN 1.5 kN*

System MI
q

HDG
0.88 kN/m 1.31 kN/m
* limitation by strain; all other loads limited by deflection L/200

Loading scenario
Type of load recommended load F recommended load F
Channel MQ-21D
for L = 1642 mm for L = 1442 mm
Fixed points
System MQ

and sliders

F
Channel position
1.61 kN 2.10 kN L

F F

0.94 kN 1.23 kN
F F F
Airconditioning
and Ventilation

0.67 kN 0.88 kN
System MQ

F 1.05 m F

1.55 kN 2.64 kN
q

1.57 kN/m 2.33 kN/m


Firestop systems

limitation by deflection L/200

page 69
System MQ

Threaded rod
and Technical
PC Software
Information

Technical data

Surface Finish Galvanized


Material composition Steel grade 4.8
Additional product information According DIN 976-1 / Form A
Medium duty

System MM
Light duty

Ordering
Thread diameter Length Order designation Sales Quantity Item Number

M6 1m Threaded rod AM6x1000 4.8 zinced 20 pc 00339792


M6 3m Threaded rod AM6x3000 4.8 zinced 20 pc 00216412
Medium duty
System MQ

M8 1m Threaded rod AM8x1000 4.8 zinced 20 pc 00339793


M8 3m Threaded rod AM8x3000 4.8 zinced 20 pc 00216415
M10 1m Threaded rod AM10x1000 4.8 zinced 20 pc 00339795
M10 3m Threaded rod AM10x3000 4.8 zinced 20 pc 00216418
M12 3m Threaded rod AM12x3000 4.8 zinced 15 pc 00216421
Hilti Pipe Rings

M16 2m Threaded rod AM16x2000 4.8 zinced 5 pc 00216423


M20 2m Threaded rod AM20x2000 4.8 zinced 5 pc 00212632
M24 2m Threaded rod AM24x2000 4.8 zinced 5 pc 00212633

Flat washer
Medium duty
System MQ

Technical data
HDG

Surface Finish Galvanized


Material composition Steel 140 HV
Stainless Steel
Medium duty
System MQ

Ordering

Inside diameter Outside Thickness Additional product information Order designation Sales Quantity Item Number
diameter

6.4 mm 12 mm 1.6 mm According DIN 125 / Form A Flat washer A 6,4/12 zinced 500 pc 00282849
System MI

8.4 mm 16 mm 1.6 mm According DIN 125 / Form A Flat washer A 8,4/16 zinced 200 pc 00282850
HDG

10.5 mm 20 mm 2 mm According DIN 125 / Form A Flat washer A 10,5/20 zinced 100 pc 00282851
13 mm 24 mm 2.5 mm According DIN 125 / Form A Flat washer A 13/24 zinced 100 pc 00282852
17 mm 30 mm 3 mm According DIN 125 / Form A Flat washer A 17/30 zinced 100 pc 00282853
21 mm 37 mm 3 mm According DIN 125 / Form A Flat washer A 21/37 zinced 50 pc 00282854
Fixed points
System MQ
and sliders

25 mm 44 mm 4 mm According DIN 125 / Form A Flat washer A 25/44 zinced 50 pc 00282855


8.4 mm 40 mm 3 mm Similar to DIN 125 / Form A Flat washer A 8,4/40 zinced 100 pc 00282856
10.5 mm 40 mm 3 mm Similar to DIN 125 / Form A Flat washer A 10,5/40 zinced 100 pc 00282857
13 mm 40 mm 3 mm Similar to DIN 125 / Form A Flat washer A 13/40 zinced 100 pc 00282858
17 mm 40 mm 3 mm Similar to DIN 125 / Form A Flat washer A 17/40 zinced 100 pc 00282859
Airconditioning
and Ventilation

System MQ

6.4 mm 28 mm 2 mm Similar to DIN 125 / Form A Flat washer A 6,4/28 zinced 200 pc 00282860
8.4 mm 28 mm 2 mm Similar to DIN 125 / Form A Flat washer A 8,4/28 zinced 200 pc 00282861
10.5 mm 28 mm 2 mm Similar to DIN 125 / Form A Flat washer A 10,5/28 zinced 100 pc 00282862
6.4 mm 18 mm 1.6 mm According DIN 9021 / Form A Flat washer A 6,4/18 zinced 200 pc 00409392
8.4 mm 24 mm 2 mm According DIN 9021 / Form A Flat washer A 8,4/24 zinced 100 pc 00409393
Firestop systems

10.5 mm 30 mm 2.5 mm According DIN 9021 / Form A Flat washer A 10,5/30 zinced 100 pc 00409394
13 mm 37 mm 3 mm According DIN 9021 / Form A Flat washer A 13/37 zinced 100 pc 00409395
17 mm 50 mm 3 mm According DIN 9021 / Form A Flat washer A 17/50 zinced 50 pc 00409396
22 mm 60 mm 4 mm According DIN 9021 / Form A Flat washer A 22/60 zinced 50 pc 00409398

page 70
System MQ

Hexagon screw

and Technical
PC Software

Information
Technical data

Surface Finish Galvanized


Material composition Steel grade 8.8

Medium duty
Additional product information According DIN 933

System MM
Light duty
Ordering
Thread diameter Thread length Wrench size Order designation Sales Quantity Item Number

M6 16 mm 10 mm Hexagon screw M6x16 zinced 100 pc 00216443


M6 25 mm 10 mm Hexagon screw M6x25 zinced 100 pc 00216444

Medium duty
System MQ
M8 16 mm 13 mm Hexagon screw M8x16 zinced 100 pc 00216446
M8 20 mm 13 mm Hexagon screw M8x20 zinced 100 pc 00216447
M8 25 mm 13 mm Hexagon screw M8x25 zinced 100 pc 00216448
M8 35 mm 13 mm Hexagon screw M8x35 zinced 100 pc 00216449
M10 20 mm 17 mm Hexagon screw M10x20 zinced 100 pc 00216453

Hilti Pipe Rings


M10 25 mm 17 mm Hexagon screw M10x25 zinced 100 pc 00216454
M10 30 mm 17 mm Hexagon screw M10x30 zinced 100 pc 00047426
M10 35 mm 17 mm Hexagon screw M10x35 zinced 100 pc 00216455
M10 55 mm 17 mm Hexagon screw M10x55 zinced 100 pc 00216456
M12 25 mm 19 mm Hexagon screw M12x25 zinced 50 pc 00216458
M12 35 mm 19 mm Hexagon screw M12x35 zinced 50 pc 00216459

Medium duty
System MQ
M12 40 mm 19 mm Hexagon screw M12x40 zinced 50 pc 00047398

HDG
M12 50 mm 19 mm Hexagon screw M12x50 zinced 50 pc 00084618
M16 30 mm 24 mm Hexagon screw M16x30 zinced 50 pc 00216461
M16 40 mm 24 mm Hexagon screw M16x40 zinced 50 pc 00047427
M16 50 mm 24 mm Hexagon screw M16x50 zinced 50 pc 00084718

Stainless Steel
Medium duty
M16 70 mm 24 mm Hexagon screw M16x70 zinced 50 pc 00387994

System MQ
M20 40 mm 30 mm Hexagon screw M20x40 zinced 50 pc 00216462

Hexagon nut
Technical data

System MI
HDG
Surface Finish Galvanized
Material composition Steel grade 8
Additional product information According DIN 934
Fixed points
System MQ

and sliders

Ordering
Thread diameter Wrench size Order designation Sales Quantity Item Number

M6 10 mm Hexagon nut M6 zinced 100 pc 00216464


M8 13 mm Hexagon nut M8 zinced 100 pc 00216465
M10 17 mm Hexagon nut M10 zinced 100 pc 00216466
Airconditioning
and Ventilation
System MQ

M12 19 mm Hexagon nut M12 zinced 100 pc 00216467


M16 24 mm Hexagon nut M16 zinced 50 pc 00216468
M20 30 mm Hexagon nut M20 zinced 50 pc 00216469
M24 36 mm Hexagon nut M24 zinced 50 pc 00216470
Firestop systems

page 71
System MQ

Threaded coupling round


and Technical
PC Software

Technical data
Information

Surface Finish Galvanized


Material composition Steel grade 4.6

Ordering
Medium duty

System MM
Light duty

Thread diameter Length Order designation Sales Quantity Item Number

M6 30 mm Spacer coupling M6x30 round 100 pc 00216433


M8 30 mm Spacer coupling M8x30 round 50 pc 00216435
M10 40 mm Spacer coupling M10x40 round 50 pc 00216438
M12 40 mm Spacer coupling M12x40 round 50 pc 00216440
Medium duty

M16 60 mm Spacer coupling M16x60 round 20 pc 00216441


System MQ
Hilti Pipe Rings

Threaded coupling
Technical data
Medium duty

Surface Finish Galvanized


System MQ

Material composition Steel grade 4.6


HDG

Ordering
Thread diameter Length Wrench size Order designation Sales Quantity Item Number

M6 18 mm 10 mm Spacer coupling M6x18 50 pc 00070063


Stainless Steel
Medium duty

M8 25 mm 13 mm Spacer coupling M8x25 50 pc 00216703


System MQ

M8 40 mm 13 mm Spacer coupling M8x40 50 pc 00432188


M10 30 mm 17 mm Spacer coupling M10x30 50 pc 00216704
M12 40 mm 19 mm Spacer coupling M12x40 50 pc 00216705
M16 40 mm 24 mm Spacer coupling M16x40 25 pc 00216706
System MI
HDG

Eye nut

Technical data
Fixed points
System MQ
and sliders

Surface Finish Galvanized


Material composition Steel C15E
Additional product information According DIN 582
Airconditioning
and Ventilation

System MQ

Ordering

Thread diameter Order designation Sales Quantity Item Number

M8 Eye nut M8 zinced 40 pc 00365873


M10 Eye nut M10 zinced 20 pc 00365808
Firestop systems

M12 Eye nut M12 zinced 10 pc 00365811


M16 Eye nut M16 zinced 10 pc 00365809
M20 Eye nut M20 zinced 6 pc 00365810
M24 Eye nut M24 zinced 4 pc 00365874

page 72
Pipe Rings System

Hilti. Outperform. Outlast.


Pipe Rings

Description Pages

MP-LHI M8 Residential pipe ring 76

MP-HI M8 / M10 Residential pipe ring 77

MP-MI Massive pipe ring 78-79

MP-MXI Massive pipe ring 80-81

MPN-RC Pipe ring 82

LH Galvanized loop hanger 83

SDC EG Clevis hanger 84

MP-SP Band hanger 85

MP-MS Double screw pipe ring 86

MI-CF Refrigeration pipe ring 87-89

MIP Refrigeration pipe ring 90-91

M-UB Round steel strap (U-bolt) 92

page 75
Pipe Rings

Residential pipe ring


and Technical

MP-LHI M8
PC Software
Information

Light duty single screw pipe ring


Medium duty

System MM
Light duty

Fields of Application
Medium duty

Technical data
System MQ

nn Light duty pipe installation up to 2”


MP-LHI M8
nn Heating pipes
Temperature resistance tem- -40°C - +110°C
nn Gas distribution pipes
perature range
Material composition DC01 steel as per DIN EN 10130
Hilti Pipe Rings

Surface Finish Galvanized


Features and Benefits
Insulation material EPDM rubber
nn Quick-release closure with only one clamping screw - easy,
quick closing and easy re-opening Hardness Insulation Material 40°±5° Shore A
nn Securely fixed rubber inlay - no loss of rubber Average noise reduction 17 dB (A)
nn Short connection boss for closer installation to wall or ceiling Connection thread M8
nn Single connection boss Wrench size 13 mm
Medium duty
System MQ

Certificates Acoustic insulation DIN 4109 in-


spected, Building material class
HDG

B2, RAL-GZ 655/1


Stainless Steel
Medium duty
System MQ

Ordering

Order designation Clamping Range Pipe size Distance Max. exten- Width - B Pipe Ring Pipe Ring Recommended Item Number
System MI

- D: Diameter (Imperial) center pipe sion from Cross Section Cross Section Static Load
to top - h center - b1 Width - b Thickness - s for Suspended
HDG

Installation Fzul
according RAL-GZ
655-B
9
Resid. pipe ring MP-LHI 8 - 12 mm 22 mm 27 mm 47 mm 20 mm 0.8 mm 200 N 02020538
8-12 M8 assy
Resid. pipe ring MP-LHI 12 - 16 mm 1/4 in 22 mm 27 mm 47 mm 20 mm 0.8 mm 400 N 02020539
Fixed points
System MQ
and sliders

12-16 M8 assy
Resid. pipe ring MP-LHI 16 - 20 mm 3/8 in 24 mm 28 mm 50 mm 20 mm 0.8 mm 400 N 02020730
16-20 M8 assy
Resid. pipe ring MP-LHI 20 - 25 mm 1/2 in 27 mm 30 mm 56 mm 20 mm 0.8 mm 400 N 02020731
20-25 M8 assy
Resid. pipe ring MP-LHI 25 - 31 mm 3/4 in 30 mm 34 mm 62 mm 20 mm 0.8 mm 400 N 02020732
Airconditioning
and Ventilation

25-31 M8 assy
System MQ

Resid. pipe ring MP-LHI 31 - 38 mm 1 in 34 mm 37 mm 70 mm 20 mm 0.8 mm 400 N 02020733


31-38 M8 assy
Resid. pipe ring MP-LHI 38 - 45 mm 1-1/4 in 37 mm 41 mm 77 mm 50 mm 1.2 mm 750 N 02020734
38-45 M8 assy
Resid. pipe ring MP-LHI 45 - 52 mm 1-1/2 in 42 mm 45 mm 85 mm 20 mm 1.2 mm 750 N 02020735
Firestop systems

45-52 M8 assy
Resid. pipe ring MP-LHI 52 - 59 mm 45 mm 49 mm 92 mm 20 mm 1.2 mm 750 N 02020736
52-59 M8 assy
Resid. pipe ring MP-LHI 59 - 66 mm 2 in 49 mm 53 mm 100 mm 20 mm 1.2 mm 750 N 02020737
59-66 M8 assy

page 76
Pipe Rings

Residential Pipe Ring

and Technical
MP-HI M8/M10

PC Software

Information
Pipe ring for installations in residential/apartment bulidings up to 6” pipe diameter with acoustic insulation.

Medium duty
System MM
Light duty
Medium duty
Fields of Application

System MQ
Technical data
nn Light duty pipe installation up to 6”
MP-HI M8/M10
nn Heating pipes
Temperature resistance -40°C - +110°C
nn Gas distribution pipes temperature range
nn Waste water distribution pipes Material composition DC01 steel as per DIN EN 10130

Hilti Pipe Rings


Surface Finish Galvanized
Insulation material EPDM rubber
Features and Benefits Hardness Insulation Material 40°±5° Shore A
nn Secure fixed rubber inlay - no loss of rubber Average noise reduction 17 dB (A)
nn Two-screw pipe ring with side swivelling mechanism Connection thread M8/M10
nn Safe click closure for easy and fast pre-fixing Wrench size 13 mm
nn Short connection boss for closer installation to wall or ceiling

Medium duty
System MQ
Certificates Acoustic insulation DIN 4109 inspected,
Building material class B2, RAL-GZ 655/1

HDG
Stainless Steel
Medium duty
System MQ
Ordering

Order designation Clamping Range Pipe size Distance Width - B Material width and Recommended Static Item Num-
- D: Diameter (Imprial) center pipe thickness (b x s) Load for Suspended In- ber
to top - h stallation Fzul according
RAL-GZ 655-B

Resid. pipe ring MP-HI 8-12 M8/M10 assy 8 - 12 mm 30 mm 52 mm 20x1.0 mm 600 N 00386402

System MI
Resid. pipe ring MP-HI 12-16 M8/M10 assy 12 - 16 mm 1/4 in 30 mm 52 mm 20x1.0 mm 600 N 00386403

HDG
Resid. pipe ring MP-HI 16-20 M8/M10 assy 16 - 20 mm 3/8 in 32 mm 57 mm 20x1.0 mm 600 N 00386404
Resid. pipe ring MP-HI 20-25 M8/M10 assy 20 - 25 mm 1/2 in 35 mm 62 mm 20x1.0 mm 600 N 00386405
Resid. pipe ring MP-HI 25-31 M8/M10 assy 25 - 31 mm 3/4 in 38 mm 69 mm 20x1.0 mm 600 N 00386406
Resid. pipe ring MP-HI 31-38 M8/10 assy 31 - 38 mm 1 in 41 mm 76 mm 20x1.0 mm 600 N 00386407
Resid. pipe ring MP-HI 38-45 M8/M10 assy 38 - 45 mm 1-1/4 in 46 mm 86 mm 20x1.2 mm 750 N 00386408
Fixed points
System MQ

and sliders

Resid. pipe ring MP-HI 45-52 M8/M10 assy 45 - 52 mm 1-1/2 in 49 mm 93 mm 20x1.2 mm 750 N 00386409
Resid. pipe ring MP-HI 52-59 M8/M10 assy 52 - 59 mm 53 mm 100 mm 20x1.2 mm 750 N 00386410
Resid. pipe ring MP-HI 59-66 M8/M10 assy 59 - 66 mm 2 in 57 mm 108 mm 20x1.2 mm 750 N 00386411
Resid. pipe ring MP-HI 66-75 M8/M10 assy 66 - 75 mm 63 mm 128 mm 25x1.8 mm 1200 N 00386412
Resid. pipe ring MP-HI 75-84 M8/M10 assy 75 - 84 mm 2-1/2 in 67 mm 137 mm 25x1.8 mm 1200 N 00386413
Airconditioning
and Ventilation
System MQ

Resid. pipe ring MP-HI 84-93 M8/M10 assy 84 - 93 mm 3 in 72 mm 146 mm 25x1.8 mm 1200 N 00386414
Resid. pipe ring MP-HI93-101 M8/M10 assy 93 - 101 mm 76 mm 155 mm 25x1.8 mm 1200 N 00386415
Resid. pipe ring MP-HI101-110M8/M10 assy 101 - 110 mm 81 mm 164 mm 25x1.8 mm 1500 N 00386416
Resid. pipe ring MP-HI110-119M8/10 assy 110 - 119 mm 4 in 86 mm 175 mm 25x2.2 mm 1500 N 00386417
Resid. pipe ring MP-HI119-129M8/M10 assy 119 - 129 mm 91 mm 185 mm 25x2.2 mm 1500 N 00386418
Firestop systems

Resid. pipe ring MP-HI129-137M8/M10 assy 129 - 137 mm 95 mm 193 mm 25x2.2 mm 1500 N 00386419
Resid. pipe ring MP-HI137-145M8/M10 assy 137 - 145 mm 5 in 100 mm 203 mm 25x2.2 mm 1500 N 00386420
Resid. pipe ring MP-HI145-155M8/M10 assy 145 - 155 mm 104 mm 211 mm 25x2.2 mm 1500 N 00386421
Resid. pipe ring MP-HI155-163M8/10 assy 155 - 163 mm 109 mm 220 mm 25x2.2 mm 1500 N 00386422
Resid. pipe ring MP-HI163-172M8/M10 assy 163 - 172 mm 6 in 113 mm 228 mm 25x2.2 mm 1500 N 00386423

*Version without acoustic insulation also available page 77


Pipe Rings

Massive Pipe Ring


and Technical

MP-MI
PC Software
Information

Medium-duty, screw-clamping pipe ring with acoustic insulation.


Medium duty

System MM
Light duty
Medium duty
System MQ

Fields of Applications Technical data


nn Duty installation up to 250 mm
MP-MI
Temperature resistance tem- -40°C - 110°C
Features and Benefits perature range
nn M8 clamping screws, secured against loss, with combination Material composition S235JRG - DIN EN 10025
Hilti Pipe Rings

cross- recess head


Surface Finish Galvanized
nn Welded-on heavy-duty nuts for clamping screw sizes 68 / 72
and above Insulation material EPDM rubber
nn Pre-assembled non-slip rubber profile Hardness Insulation Material 50°±5° Shore A
Average noise reduction 19 dB (A)
Connection thread M10/M12 (G), M16 (C)
Medium duty

Wrench size 17 mm
System MQ

Certificates
HDG

Acoustic insulation DIN 4109 in-


spected, Building material class
B2, Fire resistance tested IBMB
Nr. 3228/0041, RAL-GZ 655-B
Stainless Steel
Medium duty
System MQ
System MI
HDG

9
Fixed points
System MQ
and sliders
Airconditioning
and Ventilation

System MQ

Ordering
Order designation Clamping Range - Connection Distance Width - B Material width Recommended Static Item Number
D: Diameter Thread center pipe and thickness Load for Suspended
to top - h (b x s) Installation Fzul according
RAL-GZ 655-B

Heavy-duty pipe ring MP-MI 3/8” G 15 - 19 mm M10/M12 33 mm 64 mm 24 x 2.0 mm 1800 N 00020843


Firestop systems

Heavy-duty pipe ring MP-MI 1/2” G 20 - 25 mm M10/M12 36 mm 69 mm 24 x 2.0 mm 1800 N 00020845


Heavy-duty pipe ring MP-MI 3/4” G 25 - 30 mm M10/M12 39 mm 75 mm 24 x 2.0 mm 1800 N 00020847
Heavy-duty pipe ring MP-MI 1” G 32 - 38 mm M10/M12 42 mm 83 mm 24 x 2.0 mm 1800 N 00020849
Heavy-duty pipe ring MP-MI 1 1/4” G 40 - 45 mm M10/M12 47 mm 92 mm 24 x 2.0 mm 1800 N 00020851

page 78
Pipe Rings

Ordering

and Technical
Order designation Clamping Range - Connection Distance Width - B Material width Recommended Static Item Number

PC Software

Information
D: Diameter Thread center pipe and thickness Load for Suspended
to top - h (b x s) Installation Fzul according
RAL-GZ 655-B

Heavy-duty pipe ring MP-MI 1 1/2” G 48 - 54 mm M10/M12 50 mm 101 mm 24 x 2.0 mm 1800 N 00020853
Heavy-duty pipe ring MP-MI 54/57 G 54 - 57 mm M10/M12 53 mm 107 mm 24 x 2.0 mm 1800 N 00020855
Heavy-duty pipe ring MP-MI 2” G 57 - 64 mm M10/M12 55 mm 111 mm 24 x 2.0 mm 1800 N 00020857

Medium duty
Heavy-duty pipe ring MP-MI 68/72 G 68 - 72 mm M10/M12 60 mm 123 mm 24 x 2.0 mm 1800 N 00020860

System MM
Light duty
Heavy-duty pipe ring MP-MI 2 1/2” G 70 - 77 mm M10/M12 64 mm 130 mm 24 x 2.0 mm 1800 N 00020862
Heavy-duty pipe ring MP-MI 78/84 G 80 - 84 mm M10/M12 68 mm 139 mm 24 x 2.0 mm 1800 N 00020865
Heavy-duty pipe ring MP-MI 3” G 82 - 90 mm M10/M12 71 mm 144 mm 24 x 2.0 mm 1800 N 00020866
Heavy-duty pipe ring MP-MI 101.6 G 97 - 103 mm M10/M12 78 mm 163 mm 30 x 2.5 mm 2400 N 00020869
Heavy-duty pipe ring MP-MI 4” G 108 - 114 mm M10/M12 84 mm 174 mm 30 x 2.5 mm 2400 N 00020871

Medium duty
System MQ
Heavy-duty pipe ring MP-MI 125 G 122 - 127 mm M10/M12 90 mm 187 mm 30 x 2.5 mm 2400 N 00020876
Heavy-duty pipe ring MP-MI 133 G 132 - 137 mm M10/M12 95 mm 198 mm 30 x 2.5 mm 4500 N 00020879
Heavy-duty pipe ring MP-MI 5” G 137 - 142 mm M10/M12 98 mm 203 mm 30 x 2.5 mm 4500 N 00020882
Heavy-duty pipe ring MP-MI 159 G 156 - 162 mm M10/M12 107 mm 223 mm 30 x 2.5 mm 4500 N 00020885
Heavy-duty pipe ring MP-MI 6” G 162 - 168 mm M10/M12 110 mm 229 mm 30 x 2.5 mm 4500 N 00020887

Hilti Pipe Rings


Massive Pipe Ring
MP-MI (C)

Medium duty
System MQ

HDG
Ordering
Order designation Clamping Range - Connection Distance Width - B Material width Recommended Item Number
D: Diameter Thread center pipe and thickness Static Load for
to top - h (b x s) Suspended Installa-

Stainless Steel
Medium duty
tion Fzul according

System MQ
RAL-GZ 655-B

Heavy-duty pipe ring MP-MI 2” C 57 - 64 mm M16 56 mm 111 mm 24 x 2.0 mm 1800 N 00020858


Heavy-duty pipe ring MP-MI 2 1/2” C 70 - 77 mm M16 65 mm 130 mm 24 x 2.0 mm 1800 N 00020863
Heavy-duty pipe ring MP-MI 3” C 82 - 90 mm M16 72 mm 144 mm 24 x 2.0 mm 1800 N 00020867
Heavy-duty pipe ring MP-MI 4” C 108 - 114 mm M16 84 mm 174 mm 30 x 2.5 mm 2400 N 00020872
Heavy-duty pipe ring MP-MI 133 C 132 - 137 mm M16 96 mm 198 mm 30 x 2.5 mm 2400 N 00020880

System MI
Heavy-duty pipe ring MP-MI 159 C

HDG
156 - 162 mm M16 107 mm 223 mm 30 x 2.5 mm 4500 N 00229087
Heavy-duty pipe ring MP-MI 6” C 162 - 168 mm M16 111 mm 229 mm 30 x 2.5 mm 4500 N 00020888
Heavy-duty pipe ring MP-MI 193.7 C 190 - 200 mm M16 127 mm 263 mm 30 x 3.0 mm 4500 N 00020892
Heavy-duty pipe ring MP-MI 212 C 210 - 219 mm M16 136 mm 283 mm 30 x 3.0 mm 4500 N 00020894
Heavy-duty pipe ring MP-MI 219.1 C 217 - 224 mm M16 139 mm 288 mm 30 x 3.0 mm 4500 N 00020896
Fixed points
System MQ

and sliders

Heavy-duty pipe ring MP-MI 244.5 C 242 - 250 mm M16 152 mm 314 mm 30 x 3.0 mm 4500 N 00020898
Heavy-duty pipe ring MP-MI 267 C 267 - 273 mm M16 170 mm 338 mm 30 x 3.0 mm 4500 N 00020900

*Version without acoustic insulation also available


Airconditioning
and Ventilation
System MQ

Firestop systems

page 79
Pipe Rings

Massive pipe ring


and Technical

MP-MXI
PC Software
Information

Heavy duty pipe ring for heavy sanitary / medium industry with acoustic insulation and metric connection boss
Medium duty

System MM
Light duty
Medium duty
System MQ

Field of Applications Technical data


nn Heavy duty installation up to 508 mm
MP-MXI
nn Mechanical installations
Temperature resistance tem- -50°C - 120°C
nn Process and control lines
perature range
nn Heavy-duty pipe runs
Material composition DD11 - DIN EN 10111
Hilti Pipe Rings

Surface Finish Galvanized


Features and Benefits
Insulation material EPDM rubber
nn Solid connection boss, welded all round
Hardness Insulation Material 50°±5° Shore A
nn Strong clamping bolts for high loads
Average noise reduction 16 dB (A)
nn Non-slip, pre-fitted profiled rubber inlay
Connection thread M16
nn Suitable for the installation of pipes under dynamic loading
Medium duty
System MQ

Certificates Acoustic insulation DIN 4109 in-


spected, Building material class
HDG

B2, Fire resistance tested IBMB


Nr. 3365/7046, RAL-GZ 655-B
Stainless Steel
Medium duty
System MQ
System MI
HDG

9
Fixed points
System MQ
and sliders

Ordering
Order designation Clamping Range - Connec- Distance Width - B Material width Recommended Item Number
D: Diameter tion Thread center pipe and thickness Static Load for
to top - h (b x s) Suspended Installa-
tion Fzul according
RAL-GZ 655-B

Heavy-duty pipe ring MP-MXI 4” M16 108 - 116 mm M16 90 mm 210 mm 40 x 4.0 mm 3100 N 00372229
Airconditioning
and Ventilation

System MQ

Heavy-duty pipe ring MP-MXI 125 M16 122 - 126 mm M16 95 mm 221 mm 40 x 4.0 mm 3100 N 00372230
Heavy-duty pipe ring MP-MXI 133 M16 132 - 138 mm M16 100 mm 231 mm 40 x 4.0 mm 3100 N 00372231
Heavy-duty pipe ring MP-MXI 5” M16 139 - 144 mm M16 104 mm 238 mm 40 x 4.0 mm 3100 N 00372232
Heavy-duty pipe ring MP-MXI 159 M16 159 - 166 mm M16 115 mm 261 mm 40 x 4.0 mm 3100 N 00372233
Heavy-duty pipe ring MP-MXI 6” M16 163 - 170 mm M16 117 mm 265 mm 40 x 4.0 mm 7500 N 00372234
Firestop systems

Heavy-duty pipe ring MP-MXI 177.8 M16 177 - 182 mm M16 123 mm 284 mm 40 x 4.0 mm 7500 N 00372235
Heavy-duty pipe ring MP-MXI 193.7 M16 192 - 200 mm M16 132 mm 303 mm 40 x 4.0 mm 7500 N 00372236
Heavy-duty pipe ring MP-MXI 210 M16 210 - 218 mm M16 141 mm 321 mm 40 x 4.0 mm 7500 N 00372237
Heavy-duty pipe ring MP-MXI 219 M16 219 - 228 mm M16 146 mm 330 mm 40 x 4.0 mm 7500 N 00372238

page 80
For “extra” heavy duty

Fields of application:
■ Industrial pipe fitting
■ Mechanical installations Pipe Rings
■ Process and control lines
■ Heavy-duty pipe runs

Ordering
Benefits:

and Technical
Order designation Clamping Range - Connec- Distance Width - B Material width Recommended Item Number

PC Software

Information
■ Solid connection boss, welded all round D: Diameter tion Thread center pipe and thickness Static Load for
■ Strong clamping bolts for high loads to top - h (b x s) Suspended Installa-
tion Fzul according
■ Non-slip, pre-fitted profiled rubber inlay RAL-GZ 655-B
■ Suitable for the installation of pipes under dynamic loading if used
Heavy-duty pipe ring MP-MXI 244.5 M16 244 - 253 mm M16 158 mm 355 mm 40 x 4.0 mm 7500 N 00372239
with vibration damping components
Heavy-duty pipe ring MP-MXI 267/274 M16 267 - 274 mm M16 167 mm 375 mm 40 x 4.0 mm 7500 N 00372240
Heavy-duty pipe ring MP-MXI 275 M16 275 - 282 mm M16 173 mm 384 mm 40 x 4.0 mm 7500 N 00372241

Medium duty
Technical data:

System MM
Light duty
Heavy-duty
Max pipe
permissible loadring MP-MXI 324 M16
for suspensions 315 - 324 mm M16 190 mm 441 mm 50 x 5.0 mm 11000 N 00372242
upHeavy-duty
to 3″ pipe ring MP-MXI 326 M16 325 - 330
max. Frec.mm
= 6000M16
N 192 mm 445 mm 50 x 5.0 mm 11000 N 00372243
from 4″ up to 274 mm diameter,
Heavy-duty pipe ring MP-MXI 355 M16 max. Frec. = 10000 N
348 - 356 mm M16 205 mm 471 mm 50 x 5.0 mmBuilding
11000 N 00372244
from 324 up to 406 mm diameter max. Frec. = 15000 N material class
Heavy-duty pipe ring MP-MXI
from 457 up to 508 mm diameter 368 M16 364 - 372
max. Frec.mm M16
= 17000 N 213 mm 488 mm 50 x 5.0 mm B211000 N
„Normal flammability“
00372245
as per DIN 4102
Heavy-duty
Pipe pipe ring MP-MXI
ring material: 406 as
STW22 steel M16 400
per DIN EN 10-111
409(galvanized)
mm M16 232 mm 525 mm 50 x 5.0 mm 11000 N 00372246

Medium duty
Rubber inlay material:
Heavy-duty pipe ring MP-MXI 457 M16 454 - 462 mm EPDM

System MQ
M16 259 mm
Firestop 586 mm 70 x 6.0 mm 17000 N 00372247
Temperature resistance:
Heavy-duty pipe ring MP-MXI 508 M16
–40°C to
500 - 508 mm M16
+120°C 282 mm 632 mm 70 x 6.0 mm 17000 N 00372248
Shore A hardness: 40° ± 5° Shore-A
Noise reduction: ∆
LA = 16 dB (A)

*Version without
Fire rating data inacoustic
minutes insulation also available

Hilti Pipe Rings


Size F30 F60 F90 F120
[mm/inch] Fmax. [kN] Fmax. [kN] Fmax. [kN] Fmax. [kN]
∅ 2–3″ ≤ 1.7 ≤ 1.1 ≤ 0.85 ≤ 0.7
∅ 4″–275 mm ≤ 3.0 ≤ 2.0 ≤ 1.6 ≤ 1.35
Recommended guide values for dynamic loading of MP-MXI / MP-MX

Medium duty
System MQ
M16 connection boss, 3
/4″ connection boss, 1″ connection boss,
(max. Frec 6,000 N) (max. Frec 10,000 N) (max. Frec 10,000 N)

HDG
from pipe size 4″ (108 mm) up to 274 mm from pipe size 2″ (60 mm) up to 133 mm from pipe size 5″ (137 mm) up to 274 mm
‰ L L L L L L ‰ L L L L L L ‰ L L L L L L
mm 100 mm 200 mm 300 mm 400 mm 500 mm 1000 mm mm 100 mm 200 mm 300 mm 400 mm 500 mm 1000 mm mm 100 mm 200 mm 300 mm 400 mm 500 mm 1000 mm
0.5 ● ● ● ● ● ● 0.5 ● ● ● ● ● ● 0.5 ● ● ● ● ● ●
1 – ● ● ● ● ● 1 – ● ● ● ● ● 1 – ● ● ● ● ●

Stainless Steel
1.5 – 1.5 – 1.5 –

Medium duty
● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

System MQ
2 – ● ● ● ● ● 2 – – ● ● ● ● 2 – – ● ● ● ●
4 – – ● ● ● ● 4 – – – ● ● ● 4 – – – ● ● ●
6* – – – – ●* ● 6 – – – – ● ● 6 – – – – ● ●
8 – – – – ● ● 8 – – – – ● ● 8 – – – – ● ●
10 – – – – ● 10 – – – – – ● 10 – – – – ●
The determined values apply only if the The determined values apply only if the The determined values apply only if the

System MI
MFP-GP16 base plate and M16 threaded MFP-GP 3/4″ base plate and GR-G 3/4″ threaded MFP-GP1″ base plate and GR-R1″ threaded
rod of the 8.8 grade are used. pipe are used. pipeare used.

HDG
● Fatigue strength (2×106 load cycles) as per the S-N curve

L
Fixed points
System MQ

and sliders

* Example: Is the shown pipe fastening resistant to dynamic fatigue stressing?


Vorgabe: Known: Threaded base plate with M16 connection and anchor approved for
tension zone. Distance between and ceiling or wall, L, 500 mm.
Max. side movement caused by vibration, ‰, in mm = 6 mm
Result: Resistant to fatigue stressing (2×106 load cycles) allowing for dimension
Airconditioning

L = min. 500 mm
and Ventilation
System MQ

page 71
Firestop systems

page 81
*Version without acoustic insulation also available
Pipe Rings

page 82
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Pipe Rings

Galvanized loop hanger


LH

and Technical
PC Software

Information
Advantages
Fast installation
Low cost
System approved; FM UL
Pipe support for piping
All models are for use with ANSI/MSS SP-58 and SP-69

Medium duty
System MM
Light duty
(Type 10)
Bow: material ASTM A653M-06a,
CS Type B / galvanizing ASTM A653-06a, Z180
(thickness min. 13µm)
Nut: material 1010 acc. to SAE J403 / ASTM B633-07
(min. thickness 13 µm)
Technical data

Medium duty
System MQ
Nominal pipe size Max. recom. load
to 2” 2.0 kN
21/2” - 4” 4.5 kN
6” - 8” 8.0 kN

Hilti Pipe Rings


1 2 3 4
M

L D
A
S

Medium duty
System MQ
C
H

HDG
Load

Installation sizes1/2" – 2" (nut caulked)


1 2 3 4 5

Stainless Steel
Medium duty
System MQ
FM
APPROVED

Load

Installation sizes 1/22" – 8" (nut with washer)

System MI
HDG
Fixed points
System MQ

and sliders
Airconditioning
and Ventilation
System MQ

Firestop systems

page 83
Clevis hangers
Pipe Rings

Clevis hanger
SDC EG
and Technical
PC Software
Information

Advantages
Heavy-duty support for piping systems
All models are for use with ANSI/MSS SP-58 and SP-69
(Type 1) heavy duty sizes
Attachment to threaded rod provides easy installation and hight
adjustment
Medium duty

System MM
Light duty

Galvanized finish (ASTM B633)

Technical data
Nominal pipe size Max. recom. load
2” 2.8 kN
21/2” - 4” 4.8 kN
Medium duty
System MQ

5” 6.3 kN
6” 8.5 kN
8” 9.0 kN
10” - 12” 16.5 kN

Installation Option 1
Hilti Pipe Rings

1 2
Medium duty
System MQ
HDG

Assemble and install Slide pipe through


hanger on threaded rod assembled clevis hanger)
as shown (rod and nuts
not supplied)

Installation Option 2
1 2 3 4
Stainless Steel
Medium duty
System MQ

FM
APPROVED

UL (Underwriters Laboratories) FM (Factory Mutual)


Size range1/2" to 12" Size range 12/2" to 8" Install top on threaded Lift bottom and pipe intoInstall bolt and hexagon Load
System MI

rod as shown (rod and place nut


nuts not supplied)
HDG

Ordering designation Pipe size clamping sales package pcs/carton kg/pc UL FM Item-no.
range

SDC 1/2" EG ⁄2"


1
20 - 25 4 200 0.066 • 388634
SDC 3/4" EG ⁄4"
3
27 - 28 4 200 0.074 • 388635
Fixed points
System MQ
and sliders

SDC 1" EG 1" 34 - 35 4 200 0.084 • 388636


SDC 11/4" EG 1 1⁄4" 42 - 45 4 100 0.121 • 388637
SDC 11/2" EG 1 1⁄2" 48 - 51 4 100 0.133 • 388638
SDC 2" EG 2" 57 - 64 4 100 0.165 • 388639
SDC 21/2" EG 2 1⁄2" 72 - 78 5 50 0.385 • • 388640
SDC 3" EG 3" 83 - 89 5 50 0.430 • • 388641
Airconditioning
and Ventilation

SDC 4" EG 4" 106 - 114 4 40 0.600 • • 388642


System MQ

SDC 5" EG 5" 139 - 144 5 25 0.954 • • 388643


SDC 6" EG 6" 165 - 168 3 15 1.730 • • 388644
SDC 8" EG 8" 217 - 224 5 10 2.500 • • 388645
SDC 10" EG 10" 267 - 274 2 4 4.500 • 388646
SDC 12" EG 12" 315 - 324 2 4 5.000 • 388647
Firestop systems

page 84
Hilti Pipe
Pipe Rings
Rings

MP-SP band hanger, galvanized

and Technical
PC Software

Information
Key features
■ Rapid installation
– Insert pipe, “click” to close, saves valuable installation time
– Pre-assembled band hangers for economical pipe installation.
■ Safety first

Medium duty
– Quick-locking closure with double security thanks to a dual locking

System MM
Light duty
system; Can be opened again easily with a screwdriver.
– Single-hand installation: No risk of accident - no struggle to fit the pipe
and pipe ring to a threaded rod and no special nuts are necessary.
■ Cost saving
– Not expensive, special nuts have to be re-ordered if the standard nuts
are lost.
– Economical installation method reduces labour costs.

Medium duty
System MQ
■ System features
– Co-ordinated sprinkler system from one supplier, thus less administra-
tion work because of only one contact.
– System approved by VdS, FM and UL.
■ Compatible with Hilti MP pipe ring programmes

Hilti Pipe Rings


M8 M10

s
h

17
13

Medium duty
M12

System MQ
R M16
Loading as per VdS, FM and UL regulations

HDG
VdS FM UL
24
19

R
H

APPROVED

Stainless Steel
Medium duty
System MQ
System MI
HDG
Size Clamping range, Connecting nuts (supplied) Dimensions (mm) Package Ordering designation Item no.
D (mm) Wrench size/AF (mm) R bxs h contents
3
/4″ 27-28 M8/SW13* 15 21×1.5 50 100 MP-SP 3/4″-M 8 216592
1″ 34-35 M8/SW13* 18 21×1.5 50 100 MP-SP 1″-M 8 216593
Fixed points

1 1/4″ 42-45 M8/SW13* 23 21×1.5 58 50 MP-SP 11/4″-M 8 216594


System MQ

and sliders

1 1/2″ 48-51 M8/SW13* 26 21×1.5 65 50 MP-SP 11/2″-M 8 216595


2″ 57-64 M8/SW13* 33 21×1.5 73 50 MP-SP 2″-M8 216596
3
/4″ 27-28 M10/SW17 15 21×1.5 50 100 MP-SP 3/4″-M10 229041
1″ 34-35 M10/SW17 18 21×1.5 50 100 MP-SP 1″-M10 229042
1 1/4″ 42-45 M10/SW17 23 21×1.5 58 50 MP-SP 11/4″-M10 229043
Airconditioning
and Ventilation

1 1/2″ 48-51 M10/SW17 26 21×1.5 65 50 MP-SP 11/2″-M10 229044


System MQ

2″ 57-64 M10/SW17 33 21×1.5 73 50 MP-SP 2″-M10 229045


2 1/2″ 70-76 M10/SW17 39 20×2.5 78 25 MP-SP 21/2″-M10 216597
3″ 83-89 M10/SW17 46 20×2.5 96 25 MP-SP 3″-M10 216598
108 102-108 M10/SW17 55 20×2.5 122 25 MP-SP 108-M10 216599
4″ 108-114 M10/SW17 58 20×2.5 131 25 MP-SP 4″-M10 216600
133 133 M12/SW19 68 24×2.5 108 25 MP-SP 133-M12 216601
Firestop systems

5″ 140 M12/SW19 71 24×2.5 115 25 MP-SP 5″-M12 216602


159 159 M12/SW19 81 24×2.5 133 25 MP-SP 159-M12 216603
6″ 165-168 M12/SW19 85 24×2.5 142 25 MP-SP 6″-M12 216604
219.1 219 M16/SW24 111 36×2.5 186 10 MP-SP 219.1-M16 216605
* Approved only by VdS.

page 85
page 75
Pipe Rings

page 86
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Pipe Rings

Refrigeration pipe ring

and Technical
MI-CF

PC Software

Information
Medium duty
System MM
Light duty
Medium duty
System MQ
Fields of Application Technical data
nn Fastening pipes for refrigeration, cooling and air-conditioning
MI-CF
Material composition Closed-cell polyurethane foam 80
Features and Benefits
kg/m³ density

Hilti Pipe Rings


nn Simple pre-fitting of pipe in two-screw pipe ring with swivel
Thermal conductivity 0.03 W/mK
mechanism for main sizes
nn Everything in one package: pipe ring + pipe support Temperature resistance -80°C - +140°C
temperature range
nn Contains no H-CFC’s or CFC’s
Compressive strength 0.7 N/mm²
nn ”Impact - resistant”, combined lamination of aluminium-PET-
aluminium Loading Information Material lamination: Combined
nn Available insulation material thickness - 20, 25, 30, 40 and lamination of Al-PET-Al
Diffusion resistance: Vapour proof as

Medium duty
System MQ
50 mm.
per DIN 4108. Version: Foil over-

HDG
lapping longitudinal joint.For the
definition of the isolations thick-
ness the relevant environmental
conditions,temperature difference
and relative humidity have to be
considered

Stainless Steel
Medium duty
System MQ
Certificates Fire rating, Building material class
B2 as per DIN 4102 P.1, M1 as per
NF P92-501, B.S. 476 Part 6: 1989

System MI
HDG
9
Fixed points
System MQ

and sliders
Airconditioning
and Ventilation
System MQ

Firestop systems

page 87
Pipe Rings

page 88
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Pipe Rings

and Technical
PC Software

Information
Medium duty
System MM
Light duty
Medium duty
System MQ
MI-CF refrigeration pipe rings without load sheet
Insulating material thickness: 50 mm, hoop length: 100 mm

Hilti Pipe Rings


48.3 1 1/2 100 M10 203.0 25 x 2,5 90.5 180 2.65 8 MI-CF 48/50 372669
60.3 2 100 M16 252.5 40 x 4,0 110.5 360 2.80 6 MI-CF 60/50 372670
76.1 2 1/2 100 M16 260.5 40 x 4,0 114.5 445 3.50 6 MI-CF 76/50 372671
88.9 3 100 M16 283.7 40 x 4,0 122.5 520 3.15 4 MI-CF 89/50 372672

Medium duty
System MQ

HDG
Stainless Steel
Medium duty
System MQ
MI-CF refrigeration pipe rings with load sheet
Insulating material thickness: 50 mm, hoop length: 100 mm

60.3 2 100 96 M16 252.5 40 x 4,0 110.5 850 4.75 6 MI-CF 60/50 LS 372890
76.1 2 1/2 100 96 M16 260.5 40 x 4,0 114.5 1070 5.50 6 MI-CF 76/50 LS 372891

System MI
88.9 3 100 96 M16 283.7 40 x 4,0 122.5 1250 6.00 4 MI-CF 89/50 LS 372892

HDG
114.3 4 100 96 M16 309.0 40 x 4,0 135.0 1610 6.00 4 MI-CF 114/50 LS 372673
139.7 5 100 96 M16 327.0 40 x 4,0 145.5 1965 5.60 2 MI-CF 140/50 LS 372674
159.0 100 96 M16 355.1 40 x 4,0 158.0 2240 5.05 2 MI-CF 159/50 LS 372675
168.3 100 96 M16 363.2 40 x 4,0 162.0 2370 5.05 2 MI-CF 168/50 LS 372676
219.1 100 96 M16 429.2 40 x 4,0 184.0 3085 3.80 2 MI-CF 219/50 LS 372677
Fixed points
System MQ

and sliders

273.0 100 96 M16 475.4 40 x 4,0 207.0 3840 3.25 2 MI-CF 273/50 LS 372678
Airconditioning
and Ventilation
System MQ

Firestop systems

page 89
Pipe Rings

page 90
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Refrigeration Pipe Rings
Refrigeration pipe
pipe ring
ring

and Technical
PC Software

Information
D
D H
H

Medium duty
System MM
Light duty
B
B

MIP-M refrigeration pipe ring Insulating thickness: 20–25 mm


MIP-M refrigeration pipe ring Insulating thickness: 20–25 mm
Pipe size Clamping range, D Insulation H B Fmax Srec Connection boss/ Packaging Ordering Item no.

Medium duty
System MQ
Pipe size [mm]
[inchl] Clamping
[mm]range, D Insulation[mm] [mm]H
thickness [mm]B Fmax
[N] Srec
[m] Connection
Width acrross boss/
flats (mm) Packaging
(pcs) Ordering
designation Item no.
[inchl] [mm] [mm] thickness [mm] [mm] [mm] [N] [m] Width acrross flats (mm) (pcs) designation
/4"
1
10 10 – 13.5 20 48 89 40 2.00 M8, M10/13 AF 18 MIP-M/10-13 314144
1
3 //48"" 10
15 10 –– 18
15 13.5 20
20 48
52 89
96 40
50 2.00
2.00 M8,M10/13
M8, M10/13AFAF 1818 MIP-M/10-13
MIP-M/15-18 314144
314145
3
1
//28"" 15
25 15 –
21 – 2518 20
20 52
55 96
103 50
75 2.00
2.75 M8, M10/13AFAF
M8, M10/13 1218 MIP-M/15-18
MIP-M/21-25 314145
314146
1
3 //24"" 25
30 21 –– 30
27 25 20
21 55
57 103
109 75
75 2.75
2.75 M8,M10/13
M8, M10/13AFAF 1212 MIP-M/21-25
MIP-M/27-30 314146
314147
3
1" /4" 30
38 27 –– 38
34 30 21
22 57
64 109
115 75
150 2.75
3.50 M8,M10/17
M8, M10/13AFAF 1212 MIP-M/27-30
MIP-M/34-38 314147
314148
11"11/4" 38
44,5 34 –– 45
42 38 22
22 64
68 115
128 150
200 3.50
3.75 M8,M10/17
M8, M10/17AFAF 1212 MIP-M/34-38
MIP-M/42-45 314148
314149
1111//24"" 44,5 42 –– 49
45 22 68 128 200 3.75 M8,M10/17
M10/17AFAF 1212 MIP-M/42-45 314149

PipeS.Rings
47 23 68 128 275 4.25 M8, MIP-M/48 314150

E. & O.
1 /2" 47 –– 57
49 23 68 128 275 4.25 M8,M10/17
M10/17AFAF 1212 MIP-M/48 314150

Hilti = registered trademark of Hilti Corp., Schaan | W 2221 0808 0-en | 1 Printed in Liechtenstein | © 2008 | Right of technical and programme changes reserved S. E. & O.
54/57 54 23 75 156 300 4.25 M8, MIP-M/54-57 314151
2" 54/57
64 54 –– 64
60 57 23
23 75
79 156
163 300
475 4.25
4.75 M8,M10/17
M8, M10/17AFAF 1212 MIP-M/54-57
MIP-M/60-64 314151
314152

reserved
22"11/2" 64
80 60 –– 80
76 64 23
24 79
86 163
177 475
750 4.75
5.50 M8,M10/17
M8, M10/17AFAF 1212 MIP-M/60-64
MIP-M/76-80 314152
314154
2 /2"
3" 80 76 –– 90
88 80 24
24 86
91 177
187 750
1100 5.50
6.00 M8,M10/17
M8, M10/17AFAF 1012 MIP-M/76-80
MIP-M/89 314154
314155

Hilti
and programme changes
3" 101.6/108 88 –– 108
101 90 24
25 91
107 187
218 1100
1300 6.00
6.00 M8,M10/17
M8, M10/17AFAF 810 MIP-M/89
MIP-M/102-108 314155
314156
4" 101.6/108
114,3 101 –– 115
113 108 25
25 107
105 218
214 1300
1700 6.00
6.00 M8,M10/17
M8, M10/17AFAF 68 MIP-M/102-108
MIP-M/114 314156
314157
4" 114,3
133 113 –– 134
130 115 25
25 105
116 214
237 1700
2000 6.00
6.00 M8, M10/17
M16/21 AF AF 66 MIP-M/114
MIP-M/133 314157
314684

Medium duty
5" 133 130 –– 141
138 134 25
25 116
126 237
256 2000
2000 6.00
6.00 M16/21AFAF
M16/21 66 MIP-M/133
MIP-M/140 314684
314159

System MQ
5" 159 138 ––160
159 141 25
25 126
136 256
276 2000
2200 6.00
6.00 M16/21AFAF
M16/21 66 MIP-M/140
MIP-M/159-160 314159
314160

HDG
6" 159
168.3 159 ––168
165 160 25
25 136
136 276
276 2200
2600 6.00
6.00 M16/21AFAF
M16/21 36 MIP-M/159-160
MIP-M/165-168 314160
314161

| © 2008 | Right of technical


6" 168.3
216/219.1 165 ––219
216 168 25
25 136
154 276
364 2600
5000 6.00
6.00 M16/21AFAF
M16/24 33 MIP-M/165-168
MIP-M/216-219 314161
314162
216/219.1
273 216 –– 273
267 219 25
25 154
183 364
420 5000
6000 6.00
6.00 M16/24AFAF
M16/24 13 MIP-M/216-219
MIP-M/267-273 314162
314163
273
323,9 267 ––328
321 273 25
25 183
208 420
472 6000
8000 6.00
6.00 M16/24AFAF
M16/24 11 MIP-M/267-273
MIP-M/324 314163
314164
323,9
355 321 ––358
352 328 25
25 208
223 472
503 8000
9800 6.00
6.00 M16/24AFAF
M16/24 11 MIP-M/324
* MIP-M/356 314164
314165

in Liechtenstein Steel
355
406.4 352 ––410
403 358 25
25 223
250 503
553 9800
11400 6.00
5.40 M16/24AFAF
M16/24 11 * MIP-M/356
* MIP-M/406 314165
314166

Medium duty
System MQ
406.4
457 403 ––461
454 410 25
25 250
275 553
605 11400
12800 5.40
4.80 M16/24AFAF
M16/24 11 * MIP-M/406
* MIP-M/457 314166
314167
457 454 – 461 25 275 605 12800 4.80 M16/24 AF 1 * MIP-M/457 314167

0808 0-en | 1 PrintedStainless


MIP-T refrigeration pipe ring Insulating thickness: 31–50 mm
MIP-T
Pipe size refrigeration
Clamping range, D pipe
Insulation ringH B Insulating
Fmax Srec thickness:
Connection boss/ 31–50
Packaging mmOrdering Item no.
[inchl] [mm] [mm] thickness [mm] [mm] [mm] [N] [m] Width acrross flats (mm) (pcs) designation
Pipe size Clamping range, D Insulation H B Fmax Srec Connection boss/ Packaging Ordering Item no.
3
/8" [mm]
[inchl] 15 15 [mm]
– 18 31
thickness [mm] 62
[mm] 115
[mm] 50 [N] 2.00[m] M8,
WidthM10/17
acrross flatsAF
(mm) 20(pcs) MIP-T/15-18
designation 314168

System MI
13
/"
28 15 21
15 –– 22
18 31
31 65
62 121
115 75
50 2.75
2.00 M8,
M8,M10/17
M10/17AFAF 1620 MIP-T/21
MIP-T/15-18 314685
314168

of Hilti Corp., Schaan | W 2221HDG


1
/2" 25 24
21 –– 26
22 31
31 69
65 128
121 75
75 2.75
2.75 M8,
M8,M10/17
M10/17AFAF 1616 MIP-T/25
MIP-T/21 314169
314685
3
/4" 30
25 27
24 –– 30
26 34
31 69
69 128
128 75
75 2.75
2.75 M8,
M8,M10/17
M10/17AFAF 1216 MIP-T/27-30
MIP-T/25 314170
314169
1"
3
/4" 35
30 34
27 –– 35
30 36
34 75
69 156
128 150
75 3.50
2.75 M8,
M8,M10/17
M10/17AFAF 1212 MIP-T/34-35
MIP-T/27-30 314686
314170
1"1 38
35 37
34 –– 39
35 36
36 79
75 163
156 150
150 3.50
3.50 M8,
M8,M10/17
M10/17AFAF 1212 MIP-T/38
MIP-T/34-35 314171
314686
1 /4" 44.5
38 42
37 –– 45
39 37
36 83
79 170
163 200
150 3.75
3.50 M8,
M8,M10/17
M10/17AFAF 1212 MIP-T/42-45
MIP-T/38 314172
314171
1111//24"" 44.5 47
42 –– 49
45 37
37 83
83 170
170 275
200 4.25
3.75 M8,
M8,M10/17
M10/17AFAF 1212 MIP-T/48
MIP-T/42-45 314173
314172
Fixed points

54 51
47 –– 54 38 86 177 300 4.25 M8,
M8,M10/17
M10/17AFAF 812 MIP-T/54 314687
System MQ

and sliders

11/2" 49 37 83 170 275 4.25 MIP-T/48 314173


57
54 56
51 –– 59
54 38
38 91
86 187
177 300
300 4.25
4.25 M8,
M8,M10/17
M10/17AFAF 88 MIP-T/57
MIP-T/54 314174
314687
2" 57 60
56 –– 62
59 39
38 91
91 187
187 475
300 4.75
4.25 M8,
M8,M10/17
M10/17AFAF 68 MIP-T/60
MIP-T/57 314688
314174
Hilti = registered trademark

2"1 64 63
60 –– 65
62 39
39 97
91 196
187 475
475 4.75
4.75 M8,
M8,M10/17
M10/17AFAF 66 MIP-T/64
MIP-T/60 314175
314688
2 /2" 80 64 76
63 –– 80
65 40
39 105
97 214
196 750
475 5.50
4.75 M8,
M8,M10/17
M10/17AFAF 66 MIP-T/76-80
MIP-T/64 314177
314175
3"
21/2" 80 88
76 –– 90
80 41
40 109
105 222
214 1100
750 6.00
5.50 M16/21 AF AF
M8, M10/17 46 MIP-T/89
MIP-T/76-80 314178
314177
3" 101.6 101
88 –– 108
90 42
41 127
109 257
222 1300
1100 6.00
6.00 M16/21
M16/21AFAF 44 MIP-T/102-108
MIP-T/89 314179
314178
Airconditioning

* MIP-T/114 314180
and Ventilation

4" 101.6 113


101 –– 115
108 43 42 127
127 257
257 1700
1300 6.00
6.00 M16/21
M16/21AFAF 34 MIP-T/102-108 314179
System MQ

5"
4" 133 133
113 ––140
115 44 43 143
127 291
257 2000
1700 6.00
6.00 M16/21
M16/21AFAF 33 * MIP-T/133-140
* MIP-T/114 314182
314180
5" 159 133 159
133 –– 160
140 45 44 156
143 317
291 2200
2000 6.00
6.00 M16/21
M16/21AFAF 23 * MIP-T/159-160
* MIP-T/133-140 314183
314182
6" 168.3 159 165
159 ––169
160 45 45 149
156 362
317 2600
2200 6.00
6.00 M16/24
M16/21AFAF 22 * MIP-T/165-168
* MIP-T/159-160 314184
314183
6" 216/219.1
168.3 216
165 ––219
169 50 45 183
149 420
362 5000
2600 6.00
6.00 M16/24
M16/24AFAF 22 * MIP-T/216-219
* MIP-T/165-168 314185
314184
216/219.1 216 – 219 50 183 420 5000 6.00 M16/24 AF 2 * MIP-T/216-219 314185
Srec..: recommended support/hanger spacing DIN 1988 * Available on request
Firestop systems

Srec..: recommended
Threaded support/hanger
rods / studs spacing
must be screwed DINinto
in fully 1988
the connecting boss in the pipe ring in order to ensure achievement of*the
Available on request
given loads.
Threaded rods / studs must be screwed in fully into the connecting boss in the pipe ring in order to ensure achievement of the given loads.

Hilti. Outperform. Outlast.


Hilti. Outperform.
Hilti Corporation Outlast.
I 9494 Schaan I Liechtenstein I P +423-234 2111 I F +423-234 2965 I www.hilti.com
page 91

Hilti Corporation I 9494 Schaan I Liechtenstein I P +423-234 2111 I F +423-234 2965 I www.hilti.com
Pipe Rings

Round steel strap


and Technical

M-UB
PC Software
Information
Medium duty

System MM
Light duty

Applications Technical data


Medium duty
System MQ

nn Fastening pipes to channels and brackets M-UB


Additional product information 2 nuts and 2 washers per U-bolt
included
Material composition S235JR (DIN EN 10025-2)
Surface Finish Galvanized
Hilti Pipe Rings

Connection Height - H Width - B Clamping Range - D: Order designation Sales Quantity Item Number
thread max. Diameter

M8 59 mm 30 mm 22 mm Round steel strap M-UB 1/2” zinced 100 pc 00409319


M8 63 mm 35 mm 27 mm Round steel strap M-UB 3/4” zinced 100 pc 00409320
M8 71 mm 42 mm 34 mm Round steel strap M-UB 1” zinced 100 pc 00409321
Medium duty
System MQ

M8 79 mm 51 mm 43 mm Round steel strap M-UB 1 1/4” zinced 100 pc 00409322


HDG

M10 91 mm 59 mm 49 mm Round steel strap M-UB 1 1/2” zinced 50 pc 00409323


M10 103 mm 71 mm 61 mm Round steel strap M-UB 2” zinced 50 pc 00409324
M10 119 mm 87 mm 77 mm Round steel strap M-UB 2 1/2” zinced 50 pc 00409325
M10 131 mm 99 mm 89 mm Round steel strap M-UB 3” zinced 50 pc 00409326
Stainless Steel
Medium duty
System MQ

M12 153 mm 114 mm 102 mm Round steel strap M-UB 3 1/2” zinced 25 pc 00409327
M12 167 mm 127 mm 115 mm Round steel strap M-UB 4” zinced 25 pc 00409328
M12 191 mm 152 mm 140 mm Round steel strap M-UB 5” zinced 25 pc 00409329
M12 219 mm 180 mm 168 mm Round steel strap M-UB 6” zinced 25 pc 00409330
M16 282 mm 236 mm 220 mm Round steel strap M-UB 8” zinced 10 pc 00409331
M16 336 mm 290 mm 274 mm Round steel strap M-UB 10” zinced 10 pc 00409332
System MI
HDG
Fixed points
System MQ
and sliders
Airconditioning
and Ventilation

System MQ
Firestop systems

page 92
System MQ Channel Installation
Hot Dipped Galvanized
Hilti. Outperform. Outlast.
System MQ Hot Dipped Galvanized

Description Pages

Technical data 97-101

Installation channels - Single and Double (HDG) 102

Brackets and Angle Brace 103

Pushbutton, Wing nut and Pipe ring saddles 104-105

Channel connectors 106-107

Channel base connectors 108-109

Beam clamps 110-111

Channel accessories 112

MQ Eco connectors 113-114

Fixed points and sliders 115-117

MFP-F Heavy-duty fixed point 116-117

Pipe rings (HDG) 118-120

Accessories (HDG) (Threaded rods, nuts, washers etc.) 121-122

page 95
System MQ Hot Dipped Galvanized

page 96
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
System
System MQ channel MQ Hot hot-dip
installation Dippedgalvanised
Galvanized

Technical data Channel selections (hot-dip galvanised)

and Technical
PC Software

Information
2.5

2.75
Definition of axes 3
2

2.5
F F

124
124
2

82.6
e2 e1 2

72
y-axis

52
2

41.2
41.3
e1 e2 2.75

20.6
"open" 41.3 41.3 41.3 41.3
z-axis 41.3 41.3 41.3 41.3

Medium duty
System MM
MQ-21-F MQ-41-F MQ-52-F MQ-72-F MQ-21D-F MQ-41D-F MQ- MQ-

Light duty
52-72D-F 124XD-F
Channel wall thickness t [mm] 2.0 2.0 2.5 2.75 2.0 2.0 2,5/2.75 3.0
Cross-sectional area A [mm2] 165.3 245.1 352.1 492.8 330.6 490.3 844.9 1237.2
Channel weight [kg/m] 1.48 2.13 3.01 4.20 2.97 4.29 7.26 10.09
Delivered lenght [m] 3/6 3/6 3/6 3/6 3/6 3/6 6 6
Material
σperm. [N/mm2]

Medium duty
System MQ
Permissible stress 152.6 152.6 152.6 152.6 152.6 152.6 152.6 152.6
Cont. hot-dip galvanised (HDG plus),  70 µm
Hot-dip galvanised, min. 45 µm ● ● ● ● ● ● ● ●
Cross-section values
Y-axis
Axis of gravity "open" 1) e1 [mm] 10.84 21.13 26.67 36.79 20.60 41.30 62.02 62.00
Axis of gravity e2 [mm] 9.76 20.17 25.33 35.22 20.60 41.30 61.99 62.00

Hilti Pipe Rings


Moment of inertia Iy [cm4] 0.92 5.37 11.41 28.70 4.98 30.69 115.41 188.04
Section modulus "open" Wy1 [cm3] 0.85 2.54 4.28 7.80 2.42 7.43 18.61 30.33
Section modulus Wy2 [cm3] 0.94 2.66 4.50 8.15 2.42 7.43 18.62 30.33
Radius of gyration iy [cm] 0.74 1.48 1.80 2.41 1.23 2.50 3.70 3.90
Permissible moment 2) My [Nm] 129 388 653 1190 369 1134 2840 4628
Z-axis
Moment of inertia Iz [cm4] 4.39 7.33 10.79 15.40 8.78 14.67 26.13 31.62

Medium duty
System MQ
Section modulus Wz [cm3] 2.13 3.55 5.23 7.46 4.25 7.10 12.65 15.31

HDG
Radius of gyration iz [cm] 1.63 1.73 1.75 1.77 1.63 1.73 1.76 1.60
Selection of channel section:
● The given data is based on a single span (simply-supported beam) bearing a single load, F (kN), at mid-span, L/2.
● If several loads are acting on a single span (simply-supported beam), these may be summated and regarded as a single load acting at mid span. By taking this
approach, the design calculation is on the safe side. (➔ Cross section selection table).
● The permissible stress in the steel and the max. deflection, L/200, are not exceeded with the given max. span width, L (cm).
● The channel's own weight was taken into account.

Stainless Steel
Medium duty
System MQ
Max. span width, L (cm) / deflection f (mm) 3)
L f L f L f L f L f L f L f L f
F (kN) (cm) (mm) (cm) (mm) (cm) (mm) (cm) (mm) (cm) (mm) (cm) (mm) (cm) (mm) (cm) (mm)
0.25 133 6.7 306 15.3 419 20.9 599 29.9 288 14.4 614 30.7 936 46.8 1034 51.7
0.50 95 4.8 226 11.3 321 16.0 482 24.1 216 10.8 496 24.8 821 41.0 938 46.9
0.75 68 2.6 187 9.3 268 13.4 411 20.5 179 9.0 424 21.2 735 36.8 861 43.0
1.00 51 1.5 153 6.8 235 11.7 364 18.2 145 6.2 375 18.8 670 33.5 797 39.9

System MI
1.25 41 <1 123 4.4 204 9.5 329 16.5 116 4.1 340 17.0 618 30.9 745 37.2

HDG
1.50 34 <1 103 3.1 171 6.8 303 15.1 97 2.9 291 12.7 576 28.8 701 35.0
1.75 29 <1 88 2.3 147 5.0 264 11.7 84 2.1 252 9.6 541 27.0 663 33.1
2.00 26 <1 77 1.7 129 3.9 233 9.1 73 1.6 222 7.5 511 25.6 630 31.5
2.25 23 <1 69 1.4 115 3.1 208 7.3 65 1.3 198 6.0 470 22.2 601 30.1
2.50 20 <1 62 1.1 104 2.5 188 6.0 59 1.0 179 4.9 428 18.7 576 28.8
2.75 19 <1 56 <1 94 2.1 171 5.0 53 <1 163 4.1 393 15.8 554 27.7
Fixed points
System MQ

and sliders

3.00 17 <1 52 <1 87 1.8 157 4.2 49 <1 150 3.5 363 13.6 534 26.7
3.50 15 <1 44 <1 74 1.3 135 3.1 - - 129 2.6 315 10.3 495 24.3
4.00 13 <1 39 <1 65 <1 118 2.4 - - 113 2.0 277 8.1 439 19.4
4.50 11 <1 34 <1 58 <1 105 1.9 - - 100 1.6 248 6.5 394 15.8
5.00 10 <1 31 <1 52 <1 95 1.5 - - 90 1.3 224 5.3 358 13.1
6.00 8 <1 26 <1 43 <1 79 1.1 - - 75 <1 187 3.7 301 9.4
Airconditioning
and Ventilation
System MQ

7.00 7 <1 22 <1 37 <1 68 <1 - - - - 161 2.8 260 7.0


8.00 6 <1 19 <1 32 <1 59 <1 - - - - 141 2.1 228 5.4
Selection example: Single load
F[kN]
● 1.0 kN (≈100 kg) should be carried by a channel with a channel span Conversion kp kg N kN
width L = 100 cm (single span simply supported). 1 kp – 1 10 0,01
Solution: L/2 L/2
● Select the line showing the load, F = 1.0 kN. 1 kg 1 – 10 0,01
Firestop systems

L[cm]
● The MQ-41-F to MQ-124XD-F channels can be used because the 1N 0,1 0,1 – 0,001
permissible span width (tabluated value) is larger or equal 1 kN 100 100 1000 – F

to the required span, L = 100 cm.


1)
The smaller value (Wy1, Wy2) is decisive for the calculated bending dimension (Wy1 = Iy/e1 or Wy2 = Iy/e2).
f[mm]
2)
Perm. My = σperm.· min. (Wy1, Wy2)
3)
The channel length is max. 6.0 m. Contact Hilti technical staff about channels longer than 6.0 m!

page
page 97
5
System MQ Hot Dipped Galvanized System
SystemMQ
MQchannel
channelinstallation
installationhot-dip
hot-dipgalvanised
galvanised

Channel selection
selection diagram
diagram Load
LoadFF(kN)
25.00
25.00
(kN)
and Technical

(hot-dip galvanised)
galvanised)
PC Software
Information

Single span (simply


(simply supported)
supported)
20.00
20.00
with single load at mid span,
span, L/2
L/2 MQ-72-F
MQ-72-F
All values were calculated for
for aa permissible
permissible stress
stressof
of
σperm.
perm. (see technical data for channel
channel selection)
selection)and
andaa
deflection of L/200.
15.00
15.00

F[kN]
Medium duty

System MM
Light duty

MQ-52-F
MQ-52-F
10.00
10.00

L/2 L/2
L[cm] 5.00
5.00
MQ-41-F
MQ-41-F
Medium duty
System MQ

MQ-21-F
MQ-21-F
0.00
0.00
00 25
25 50
50 100
100 150
150 200
200 250
250 300
300
Span
Spanwidth
width(cm)
(cm)
Load
LoadFF(kN)
(kN)
30.00
30.00
Hilti Pipe Rings

MQ-124X
MQ-124XD-F
D-F

25.00
25.00

20.00
20.00
Medium duty
System MQ

15.00
15.00
HDG

MQ-52-72D-F
MQ-52-72D-F
10.00
10.00
Stainless Steel
Medium duty
System MQ

5.00 MQ-41D-F
5.00 MQ-41D-F

MQ-21D-F
MQ-21D-F
0.00
0.00 0 25 100 200 300 400 500 600
0 25 100 200 300 400 500 600
Span width (cm)
Span width (cm)

Channel
Channel selection
selection table
table (hot-dip
(hot-dip galvanised)
System MI

galvanised)
HDG

Single span (simply supported)


Single span (simply supported) 2.5
2.75

with single load at mid span, L/2 2.5 3


2.75

with single load at mid span, L/2 2 3


2.52.5

124

124

2
124

124
2 2

82.6

2
72

82.6

2
F[kN]
72
52 52
2 2

41.2
41.3

2.75
F[kN]
41.2
20.6

41.3

2.75
20.6
Fixed points

41.3 41.3 41.3


System MQ

41.3 41.3 41.3 41.3


and sliders

41.3
41.3 41.3 41.3 41.3 41.3
L/2 L/2 41.3 41.3 41.3

L/2 L/2
L[cm]
L[cm] Max. load, F (kN) / deflection, f (mm)
Max.MQ-21-F
load, F (kN) / deflection,
MQ-41-F
f (mm)
MQ-52-F MQ-72-F MQ-21-D-F MQ-41 D-F MQ-52-72 D-F MQ-124 XD-F
MQ-21-F MQ-41-F MQ-52-F MQ-72-F MQ-21-D-F MQ-41 D-F MQ-52-72 D-F MQ-124 XD-F
Span width F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm)
LSpan
(cm)width Fmax.
(kN) L/200
f (mm) Fmax.
(kN) L/200
f (mm) F (kN)
max. f (mm)
L/200 F (kN)
max. f (mm)
L/200 F (kN)
max. f (mm)
L/200 F (kN)
max. f (mm)
L/200 F (kN) L/200
max. f (mm) F (kN)
max. f (mm)
L/200
L (cm) max. L/200 max. L/200 max. L/200 max. L/200 max. L/200 max. L/200 max. L/200 max. L/200
25 2.05 <1 6.16 <1 10.37 0.1 18.93 <1 3.00 <1 6.00 <1 11.20 <1 73.63 <1
Airconditioning
and Ventilation

25 2.05 <1 6.16 <1 10.37 0.1 18.93 <1 3.00 <1 6.00 <1 11.20 <1 73.63 <1
System MQ

50 1.03 1.4 3.09 <1 5.21 0.6 9.5 <1 2.94 0.7 6.00 <1 11.20 <1 36.95 <1
50 1.03 1.4 3.09 <1 5.21 0.6 9.5 <1 2.94 0.7 6.00 <1 11.20 <1 36.95 <1
75 0.68 3.1 2.06 1.6 3.47 1.3 6.33 <1 1.96 1.7 6.00 <1 11.20 <1 24.63 <1
75 0.68 3.1 2.06 1.6 3.47 1.3 6.33 <1 1.96 1.7 6.00 <1 11.20 <1 24.63 <1
100 0.45 5.0 1.54 2.9 2.59 2.3 4.74 1.6 1.46 2.9 4.51 1.5 11.20 1.0 18.46 1.0
100 0.45 5.0 1.54 2.9 2.59 2.3 4.74 1.6 1.46 2.9 4.51 1.5 11.20 1.0 18.46 1.0
125 0.28 6.3 1.23 4.5 2.07 3.6 3.78 2.6 1.16 4.6 3.60 2.3 9.04 1.5 14.75 1.5
125 0.28 6.3 1.23 4.5 2.07 3.6 3.78 2.6 1.16 4.6 3.60 2.3 9.04 1.5 14.75 1.5
150 0.19 7.5 1.02 6.5 1.72 5.1 3.14 3.7 0.96 6.6 2.99 3.3 7.52 2.2 12.27 2.2
150 0.19 7.5 1.02 6.5 1.72 5.1 3.14 3.7 0.96 6.6 2.99 3.3 7.52 2.2 12.27 2.2
175 0.14 8.8 0.86 8.8 1.47 7.0 2.68 5.1 0.79 8.8 2.55 4.5 6.43 3.0 10.49 3.0
Firestop systems

175 0.14 8.8 0.86 8.8 1.47 7.0 2.68 5.1 0.79 8.8 2.55 4.5 6.43 3.0 10.49 3.0
200 0.10 10.0 0.65 10.0 1.28 9.1 2.34 6.6 0.59 10.0 2.23 5.9 5.61 3.9 9.16 3.9
200 0.10 10.0 0.65 10.0 1.28 9.1 2.34 6.6 0.59 10.0 2.23 5.9 5.61 3.9 9.16 3.9
225 0.07 11.3 0.51 11.3 1.09 11.3 2.07 8.4 0.46 11.3 1.97 7.5 4.97 5.0 8.12 5.0
225 0.07 11.3 0.51 11.3 1.09 11.3 2.07 8.4 0.46 11.3 1.97 7.5 4.97 5.0 8.12 5.0
275 0.04 13.8 0.32 13.8 0.71 13.8 1.68 12.5 0.28 13.8 1.59 11.2 4.03 7.4 6.60 7.4
275 0.04 13.8 0.32 13.8 0.71 13.8 1.68 12.5 0.28 13.8 1.59 11.2 4.03 7.4 6.60 7.4
300 0.02 15.0 0.26 15.0 0.58 15.0 1.53 15.0 0.22 15.0 1.45 13.3 3.68 8.8 6.02 8.8
300 0.02 15.0 0.26 15.0 0.58 15.0 1.53 15.0 0.22 15.0 1.45 13.3 3.68 8.8 6.02 8.8
page 7
page 98 page 7
System MQ channel installation HDG plus System MQ Hot Dipped Galvanized

Technical data Channel selections (HDG plus)

and Technical
PC Software

Information
2

2
Definition of axes

82.6
2
2

41.2
41.3
F F

31
20.6
e2 e1 41.3 41.3
41.3 41.3 41.3
y-axis
e1 e2
"open" z-axis
MQ-21- MQ-31- MQ-41- MQ-21D- MQ-41D-

Medium duty
HDG plus HDG plus HDG plus HDG plus HDG plus

System MM
Light duty
Channel wall thickness t [mm] 2.0 2.0 2.0 2.0 2.0
Cross-sectional area A [mm2] 165.3 204.9 245.1 330.6 490.3
Channel weight [kg/m] 1.48 1.80 2.13 2.98 4.29
Delivered length [m] 6 6 6 6 6
Material
Permissible stress σperm. [N/mm2] 188.3 181.8 175.3 188.3 175.3

Medium duty
Cont. hot-dip galvanised (HDG plus), 70 µm ● ● ● ● ●

System MQ
Hot-dip galvanised, min. 45 µm
Cross-section values
Y-axis
Axis of gravity "open" 1) e1 [mm] 10.84 16.01 21.13 20.60 41.30
Axis of gravity e2 [mm] 9.76 14.99 20.17 20.60 41.30
Moment of inertia Iy [cm4] 0.92 2.60 5.37 4.98 30.69

Hilti Pipe Rings


Section modulus "open" Wy1 [cm3] 0.85 1.62 2.54 2.42 7.43
Section modulus Wy2 [cm3] 0.94 1.73 2.66 2.42 7.43
Radius of gyration iy [cm] 0.74 1.13 1.48 1.23 2.50
Permissible moment 2) My [Nm] 159 295 446 455 1303
Z-axis
Moment of inertia Iz [cm4] 4.39 5.83 7.33 8.78 14.67
Section modulus Wz [cm3] 2.13 2.82 3.55 4.25 7,10

Medium duty
System MQ
Radius of gyration iz [cm] 1.63 1.69 1.73 1.63 1.73
Selection of channel section:

HDG
● The given data is based on a single span (simply-supported beam) bearing a single load, F (kN), at mid-span, L/2.
● If several loads are acting on a single span (simply-supported beam), these may be summated and regarded as a single load acting at mid span. By taking this
approach, the design calculation is on the safe side. (➔ Cross section selection table).
● The permissible stress in the steel and the max. deflection, L/200, are not exceeded with the given max. span width, L (cm).
● The channel's own weight was taken into account.
● HDG plus channels: The permissible stress σD / γG/Q where γ = 1.4. σD results from the higher yield strength (point) resulting from cold forming as per

Stainless Steel
DAST-RILI 016 from 1992: σD = fyk / γM where γM = 1.1

Medium duty
System MQ
Max. span width, L (cm) / deflection f (mm) 3)
L f L f L f L f L f
F (kN) (cm) (mm) (mm) (mm) (cm) (mm) (cm) (mm) (cm) (mm)
0.25 133 6,7 218 10.9 306 15.3 288 14.4 614 30.7
0.50 95 4,8 159 7.9 226 11.3 216 10.8 496 24.8
0.75 78 3,9 131 6.5 187 9.3 179 9.0 424 21.2
1.00 63 2,8 114 5.7 163 8.1 156 7.8 375 18.8

System MI
1.25 51 1,8 94 4.0 141 6.6 140 7.0 340 17.0

HDG
1.50 42 1,2 78 2.8 118 4.6 120 5.3 313 15.6
1.75 36 <1 67 2.0 101 3.4 103 3.9 288 14.1
2.00 32 <1 59 1.6 89 2.6 90 3.0 254 11.0
2.25 28 <1 52 1.2 79 2.1 80 2.4 227 8.9
2.50 25 <1 47 1.0 71 1.7 72 1.9 205 7.3
2.75 23 <1 43 <1 65 1.4 66 1.6 187 6.1
Fixed points
System MQ

and sliders

3.00 21 <1 39 <1 59 1.2 60 1.3 172 5.1


3.50 18 <1 34 <1 51 <1 – – 148 3.8
4.00 16 <1 29 <1 44 <1 – – 129 2.9
4.50 14 <1 26 <1 39 <1 – – 115 2.3
5.00 12 <1 23 <1 36 <1 – – 104 1.9
6.00 10 <1 19 <1 30 <1 – – 87 1.3
Airconditioning
and Ventilation

7.00 9 <1 17 <1 25 <1 – – – –


System MQ

8.00 7 <1 14 <1 22 <1 – – – –

Selection example: Single load


F[kN]
● 1.0 kN (≈100 kg) should be carried by a channel with a channel span Conversion kp kg N kN
width L = 100 cm (single span simply supported). 1 kp – 1 10 0,01
Solution: 1 kg 1 – 10 0,01 L/2 L/2
Firestop systems

● Select the line showing the load, F = 1.0 kN. L[cm]


● The MQ-31-HDG plus to MQ-41D-HDG plus channels can be used 1N 0,1 0,1 – 0,001
F
because the permissible span width (tabluated value) is larger or 1 kN 100 100 1000 –
equal to the required span, L = 100 cm.
1)
The smaller value (Wy1, Wy2) is decisive for the calculated bending dimension (Wy1 = Iy/e1 or Wy2 = Iy/e2). f[mm]
2)
Perm. My = σperm.· min. (Wy1, Wy2)
3)
The channel length is max. 6.0 m. Contact Hilti technical staff about channels longer than 6.0 m!

page 4 page 99
System
System MQ
MQ Hot Dipped
channel
channel Galvanized
installation
installation HDG
HDG plus
plus

Channel selection
selection diagram
diagram
Load,
Load,FF(kN)
25.00
25.00
(kN)
and Technical

(HDG-plus) Single
Single span
span
PC Software
Information

(simply supported)
supported)
20.00
20.00
with single load at mid
mid span,
span, L/2
L/2
All values were calculated
calculated for
for aa permissible
permissiblestress
stressof
of
σperm.
perm. (see technical data
data for
for channel
channel selection)
selection)and
andaa
deflection of L/200.
15.00
15.00
Medium duty

System MM
Light duty

F[kN]
F[kN] 10.00
10.00
MQ-41-
MQ-41-
HDG
HDGplus
plus

L/2 L/2
L/2 5.00
5.00 MQ-31-
MQ-31-
L[cm] HDG
HDGplus
plus
Medium duty
System MQ

MQ-21-
MQ-21-
HDG
HDGplus
plus
0.00
0.000
0 2525 5050 100
100 150
150 200
200 250
250 300
300
Span width
Span (cm)
width (cm)
Load
LoadFF(kN)
(kN)
30.00
30.00
Hilti Pipe Rings

25.00
25.00

20.00
20.00
Medium duty
System MQ

15.00
15.00
HDG

10.00
10.00

MQ-41D-HDG plus
Stainless Steel

MQ-41D-HDG plus
Medium duty
System MQ

5.00
5.00 MQ-21D-HDG plus
MQ-21D-HDG plus

0.00
0.00 0 25 100 200 300 400 500 600
0 25 100 200 300 400 500
Span width (cm)600
Span width (cm)

Channel
Channel selection
selection table
table (HDG
(HDG plus)
System MI

plus)
HDG

Single span (simply supported)


Single span (simply supported)
with single load at mid span, L/2
with single load at mid span, L/2 2
2
2

82.6

2
2 2

82.6

F[kN] 2
2 2

41.2
41.3

F[kN]
31

41.2
20.620.6

41.3
31
Fixed points
System MQ

41.3 41.3
and sliders

41.3 41.3 41.3


L/2 L/2 41.3 41.3 41.3 41.3 41.3
L/2 L/2
L[cm]
L[cm] Max. load, F (kN) / deflection, f (mm)
Max. load, F (kN) / deflection, MQ-31-
MQ-21-
f (mm) MQ-41- MQ-21 D- MQ-41 D-
MQ-21-
HDG plus MQ-31-
HDG plus MQ-41-
HDG plus MQ-21
HDG plusD- MQ-41
HDG plusD-
Span width F (kN)HDG plus
f (mm) F (kN)HDG plus
f (mm) HDG plus
F (kN) f (mm) F (kN)HDG plus
f (mm) F (kN)HDG plus
f (mm)
LSpan
(cm)width Fmax.
(kN) f (mm)
L/200 F (kN)
max. f (mm)
L/200 F (kN)
max. f (mm)
L/200 F (kN)
max. f (mm)
L/200 F (kN)
max. f (mm)
L/200
L (cm) max. L/200 max. L/200 max. L/200 max. L/200 max. L/200
25 2.53 <1 4.68 <1 7.08 <1 3.00 <1 6.00 <1
Airconditioning
and Ventilation

25 2.53 <1 4.68 <1 7.08 <1 3.00 <1 6.00 <1
System MQ

50 1.27 1.7 2.35 1.1 3.56 <1 3.00 <1 6.00 <1
50 1.27 1.7 2.35 1.1 3.56 <1 3.00 <1 6.00 <1
75 0.82 3.8 1.56 2.5 2.37 1.9 2.42 2.0 6.00 <1
75 0.82 3.8 1.56 2.5 2.37 1.9 2.42 2.0 6.00 <1
100 0.45 5.0 1.17 4.5 1.77 3.3 1.81 3.6 5.19 1.7
100 0.45 5.0 1.17 4.5 1.77 3.3 1.81 3.6 5.19 1.7
125 0.28 6.3 0.82 6.3 1.41 5.2 1.44 5.7 4.14 2.6
125 0.28 6.3 0.82 6.3 1.41 5.2 1.44 5.7 4.14 2.6
150 0.19 7.5 0.57 7.5 1.17 7.4 1.09 7.5 3.44 3.8
150 0.19 7.5 0.57 7.5 1.17 7.4 1.09 7.5 3.44 3.8
175 0.14 8.8 0.41 8.8 0.86 8.8 0.79 8.8 2.94 5.2
Firestop systems

175 0.14 8.8 0.41 8.8 0.86 8.8 0.79 8.8 2.94 5.2
200 0.10 10.0 0.31 10.0 0.65 10.0 0.59 10.0 2.56 6.8
200
225 0.10
0.07 10.0
11.3 0.31
0.23 10.0
11.3 0.65
0.51 10.0
11.3 0.59
0.46 10.0
11.3 2.56
2.27 8.66.8
225
275 0.07
0.04 11.3
13.8 0.23
0.14 11.3
13.8 0.51
0.32 11.3
13.8 0.46
0.28 11.3
13.8 2.27
1.84 8.6
12.8
275
300 0.04
0.02 13.8
15.0 0.14
0.11 13.8
15.0 0.32
0.26 13.8
15.0 0.28
0.22 13.8
15.0 1.84
1.64 12.8
15.0
300 0.02 15.0 0.11 15.0 0.26 15.0 0.22 15.0 1.64 15.0
page 6
page
page 6100
System MQ channel installation hot-dip galvanised System MQ Hot Dipped Galvanized

Technical data for brackets (hot-dip galvanised)

and Technical
PC Software

Information
Type of load 1: uniform Type of load 2: single Type of load 3 Type of load 4 Type of load 5
F1 F1 F2 F2 F3 F3 F3
F1 = q · I 1/
2
1/
2 1/
3
1/
3
1/
3
1/ 1/ 1/ 1/
4 4 4 4

F1 [N] F1 [N] F1 [N] F2 [N] F3 [N]


Channel
Bracket L (mm) HVZ-R M12
1)
HST-R M12
2)
HVZ-R M12 HST-R M12
1)
HVZ-R M12
2)
HST-R M12
1)
HVZ-R M12
2)
HST-R M12
1)
HVZ-R M12
2)
HST-R M12
1) 2)

Medium duty
System MM
MQK-21/300-F 300 850 850 850 850 420 420 420 420 280 280

Light duty
MQK-21/450-F 450 500 500 560 560 180 180 280 280 180 180
MQK-41/300-F 300 2560 2560 2560 2560 1280 1280 1280 1280 850 850
MQK-41/450-F 450 1710 1710 1710 1710 850 850 850 850 570 570
MQK-41/600-F 600 1270 1270 1270 1270 620 620 630 630 420 420
MQK-41/1000-F 1000 580 580 750 750 210 210 360 360 220 220
MQK-41/600/4-F 600 1270 1270 1270 1270 620 620 630 630 420 420
MQK-41/1000/4-F 1000 580 580 750 750 210 210 360 360 220 220

Medium duty
System MQ
MQK-72/450-F 450 5260 3180 5260 3180 2630 1590 2630 1590 1750 1060
MQK-72/600-F 600 3930 2380 3930 2380 1970 1190 1960 1190 1310 790
MQK-21 D/300-F 300 2430 2430 2430 2430 1220 1220 1210 1210 810 810
MQK-21 D/450-F 450 1620 1620 1620 1620 810 810 810 810 540 540
MQK-21 D/600-F 600 1210 1210 1210 1210 570 570 600 600 400 400
MQK-41 D/1000-F 1000 2220 1400 2220 1400 1110 700 1110 700 740 460

Hilti Pipe Rings


1)
Loading capacity of the bracket (steel loading capacity) or with HVZ-R M12 fastening, the loading capacity of the bracket is reached with the HVZ-R M12.
2)
Loading capacity of the bracket with HST-R fastening, alternatively, loading values with HIT-RTZ M12 are at least those with HST-R M12.
Load values are for grade C20/25 concrete (≈ B25).
Alternatively, fastening in solid or hollow brick with HIT HY 50 and approval is possible. Use stainless-steel anchor rods (loading values not given in this table).
The bracket’s own weight has been allowed for.
The loads apply only if the bracket is fastened away from a building component edge (fastenings made at component edges must be designed separately).
Separate verification must be provided that forces are transferred to the respective base material, i.e. steel and concrete.
The application guidelines in anchor approvals must be observed. Loading values according to approval status July 2005.

Medium duty
The deflection (deformation) of L/150 was observed in all cases, this being measured at the point of load application.

System MQ

HDG
HVZ-R adhesive anchor HST-R stud anchor
® ®

Stainless Stainless
steel steel

Stainless Steel
Medium duty
System MQ
Technical data for brackets with angle brace (hot-dip galvanised)
Type of load 1: uniform Type of load 2: single Type of load 3 Type of load 4 Type of load 5
F1 F1 F2 F2 F3 F3 F3
F1 = q · I 1/2 1/2 1/3 1/3 1/3 1/4 1/4 1/4 1/4

System MI
HDG
Bracket L (mm) Brace F1 [N] 1) F1 [N] 1) F1 [N] 1) F2 [N] 1) F3 [N] 1)
MQK-21/450 -F 450 short 4420 1140 520 1970 1750
MQK-41/450-F 450 short 6390 3450 2390 3190 2130
MQK-41/600-F 600 long 5540 2580 2840 2510 1890
MQK-41/1000-F 1000 long 2250 3400 430 1700 1130
Fixed points
System MQ

and sliders

MQK-41/600/4-F 600 long 5540 2580 2840 2510 1890


MQK-41/1000/4-F 1000 long 2250 3400 430 1700 1130
MQK-72/450-F 450 short 6380 6380 3190 3190 2120
MQK-72/600-F 600 long 5680 5680 2840 2840 1890
MQK-21 D/450-F 450 short 6380 3280 2270 3190 2120
MQK-21 D/600-F 600 long 5260 2450 2840 2390 1870
MQK-41 D/1000-F 1000 long 3380 3380 1690 1690 1120
Airconditioning
and Ventilation
System MQ

1)
Loading capacity of the bracket (steel loading capacity) or the loading capacity of the bracket is reached with the HVZ-R, HIT-RTZ or HST-R M12 fastening.
Load values are for grade C20/25 concrete (≈ B25).
Alternatively, fastening in solid or hollow brick with HIT HY 50 and approval is possible. Use stainless-steel anchor rods (loading values not given in this table).
The bracket’s own weight has been allowed for.
The loads apply only if the bracket is fastened away from a building component edge (fastenings made at component edges must be designed separately).
Separate verification must be provided that forces are transferred to the respective base material, i.e. steel and concrete.
Firestop systems

The application guidelines in anchor approvals must be observed. Loading values according to approval status July 2005.
The deflection (deformation) of L/150 was observed in all cases, this being measured at the point of load application.

page 8 page 101


430799*
430804*
MQ-52 -6m HDG ASTM
MQ-72 -6m HDG ASTM
3.01
4.20
System MQ Hot Dipped Galvanized

2.75
2.5
HDG ASTM

page 102
52
72
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
page 103
System MQ Hot Dipped Galvanized

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
304134
MQM-M12-F

40
4.5
3.0
500
System MQ Hot Dipped Galvanized

8.0
25

5.0
36

MQM-M12-F

page 104
M12
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
System MQ channel installation hot-dip galvanised System MQ Hot Dipped Galvanized

Pipe ring saddle

and Technical
PC Software

Information
Features:
■ Single part, simple and time-saving in use.
■ For all types of channels.
■ For threaded roads from M8 to M16.

Medium duty
System MM
Light duty
Technical data:

Medium duty
Galvanising: hot-dip galvanised, min. 56 µm

System MQ
MQA-F pipe ring saddle (HDG) M 8
M10
Nut: EN-GJMW-450-7 as per DIN EN 1562 M12
M16
Plate: S 235 JR as per DIN EN 10 025

Hilti Pipe Rings


Plastic: PB
Connection Weight Packaging Outside packaging Ordering Item no.
thread each (g) contents (pcs) contents (pcs) designation
M8 75 25 200 ➀ MQA-M 8-F 304138
M10 73 25 200 ➁ MQA-M10-F 304139
M12 71 25 200 ➁ MQA-M12-F 304140
M16 82 25 200 ➁ MQA-M16-F 304141

Medium duty
System MQ
Rec. tensile load Tightening torque, Bending moment, threaded rod 4.6
Zrec (kN) MD (Nm) (Nm) 1)

HDG
Item Channel I/II Channel III
MQA-M 8-F 3.0 3.0 9 6.4
MQA-M10-F 5.0 5.0 18 12.8
MQA-M12-F 5.0 8.0 31 22.4
MQA-M16-F 5.0 8.0 40 56.9

Stainless Steel
Medium duty
Channel I: MQ-21-F, MQ-41-F, MQ-21D-F, MQ-41D-F

System MQ
Channel II: MQ-21-HDG plus, MQ-31-HDG plus, MQ-41-HDG plus, MQ-21D-HDG plus, MQ-41D-HDG plus
Channel III: MQ-52-F, MQ-72-F, MQ-52-72D-F, MQ-124XD-F
1)
Calculation as per DIBt

Pipe ring saddles ➁ firestop tested

System MI
HDG
IBMB no. 3897/1802-5

MQG-2-F baseplate (HDG) M16


1/2" 155
50

3/4"
Material: S 235 JR as per DIN EN 10 025 1"

Galvanising: hot-dip galvanised, 56 µm


Fixed points
System MQ

and sliders

Connection Weight Packaging Ordering Item no. 100


thread each (g) contents (pcs) designation
M16 180 20 MQG-2-M16-F 304146
1
/2″ 200 20 MQG-2-1/2″-F 304147
3
/4″ 210 20 MQG-2-3/4″-F 304148
1″ 220 20 MQG-2-1″-F 304149
Airconditioning
and Ventilation
System MQ

Rec. tensile load, Rec. shear load, Tightening torque Bending moment,
Zrec (kN) Qrec (kN) MD (Nm) threaded rod 4.6 (Nm)
Item: Channel I/III Channel II
MQG-2-M16-F 6.0 5.0 8.0 40 56.9
MQG-2-1/2″-F 6.0 5.0 8.0 40 22.4
MQG-2-3/4″-F 6.0 5.0 8.0 40 100.0
Firestop systems

MQG-2-1″-F 6.0 5.0 8.0 40 193.0


Channel I: MQ-21-F, MQ-41-F, MQ-21D-F, MQ-41D-F
Channel II: MQ-21-HDG plus, MQ-31-HDG plus, MQ-41-HDG plus, MQ-21D-HDG plus, MQ-41D-HDG plus
Channel III: MQ-52-F, MQ-72-F, MQ-52-72D-F, MQ-124XD-F

page 12 page 105


System MQ Hot Dipped Galvanized System MQ channel installation hot-dip galvanised

Angles, angle brackets,


and Technical

connectors
PC Software
Information

Features: 19.4 19

■ Universal: few parts for all applications.


■ Easy to use.
■ Three-dimensional, thus high strength. 35 10

■ The MQN-F pushbutton can be prefitted


Medium duty

System MM
Light duty

Technical data:
Material: S 235 JR as per DIN EN 10025
Material thickness: 4 mm
Medium duty

Galvanising: hot-dip galvanised, min. 56 µm


System MQ

90 º angle (HDG)
Weight Packaging Ordering Item no.
each (g) contents (pcs) designation
Angle, 2 hole, 90° 110 20 ➀ MQW-2-F 304171
Hilti Pipe Rings

Angle, 4 hole, 90° 220 10 ➁ MQW-4-F 304174


Angle, 8 hole, 90° 420 10 ➂ MQW-8/90°-F 304175
Angle, 3 hole, 90° 160 20 ➃ MQW-3-F 304172
Angle, 2 hole, 90° 160 10 ➄ MQW-P2-F 304177
MQ-F (HDG):
➀ Frec 3.0 kN Frec 2.4 kN ➁ MQ-F (HDG): ➂ MQ-F (HDG):
Frec 5.4 kN Frec
Frec 3.0 kN Frec 3.0 kN 5.0 kN
Medium duty
System MQ

61 61
HDG

55
105

MQ-HDG plus:
MQ-HDG plus: MQ-HDG plus:
Frec 3.0 kN Frec 2.4 kN
Frec 4.5 kN Frec 3.7 kN Frec 8.1 kN Frec 5.0 kN

➃ MQ-F (HDG): ➄ 46

Frec 5.4 kN Frec 2.5 kN


Stainless Steel
Medium duty
System MQ

61
111

46

MQ-HDG plus:
Frec 6.8 kN Frec 2.5 kN

45 º angle (HDG)
System MI
HDG

Weight Packaging Ordering Item no.


each (g) contents (pcs) designation
Angle, 8 hole, 45° 410 10 ➀ MQW-8/45°-F 304176
Angle, 3 hole, 45° 155 20 ➁ MQW-3/45°-F 304173
Angle, 2 hole, 45° inner 354 10 ➂ MQW-2/45°-F 304178
Fixed points

➀ ➁ ➂
System MQ
and sliders

MQ-F (HDG): MQ-F (HDG): MQ-F (HDG):


Frec 5.4 kN Frec 5.0 kN Frec 4.2 kN Frec 2.5 kN 100 Frec 3.0 kN Frec 1.1 kN
105

106
45°
45°

45°
56

MQ-HDG plus: MQ-HDG plus: MQ-HDG plus:


Frec 8.1 kN Frec 5.0 kN Frec 6.3 kN Frec 2.5 kN Frec 3.0 kN Frec 1.1 kN
Airconditioning
and Ventilation

100
System MQ

135º angle (HDG) MQ-F (HDG):


Frec 3.0 kN Frec 3.0 kN
Weight Packaging Ordering Item no.
each (g) contents (pcs) designation 85

Angle, 3 hole, 135° 210 10 MQW-3/135°-F* 304179


Firestop systems

45°

* Available on request
MQ-HDG plus:
Frec 4.5 kN Frec 3.0 kN
55

page 106 page 13


System MQ channel installation hot-dip galvanised System MQ Hot Dipped Galvanized

110
Angle bracket (HDG) ➀ MQ-F (HDG):
Frec 2.0 kN

and Technical
PC Software

Information
Frec 2.0 kN
Weight Packaging Ordering Item no.
each (g) contents (pcs) designation
155
Angle bracket, one brace 460 10 ➀ MQW-S/1-F 304180 118 MQ-HDG plus:
Frec 2.0 kN Frec 2.0 kN
Angle bracket, two braces 1180 10 ➁ MQW-S/2-F 304181
13.5

MQ-F (HDG): MQ-F (HDG):


Frec 2.0 kN Frec 3.0 kN Frec 5.4 kN Frec 5.0 kN
Angle bracket ➃ with VdS approval

Medium duty
System MM
Light duty
VdS
MQ-HDG plus: MQ-HDG plus:
Frec 2.0 kN Frec 3.0 kN Frec 8.0 kN Frec 5.0 kN
For VdS-approved installation see www.hilti.com/vds-installation
➁ 198

Medium duty
System MQ
MQ-F (HDG):
Frec 3.0 kN
Frec 3.0 kN

198 MQ-HDG plus:


Frec 3.0 kN Frec 3.0 kN
100

Hilti Pipe Rings


13.5

MQ-F (HDG): MQ-F (HDG):


Frec 4.0 kN Frec 5.4 kN Frec 5.4 kN Frec 5.4 kN

MQ-HDG plus: MQ-HDG plus:

Medium duty
Frec 4.0 kN Frec 6.0 kN Frec 8.1 kN Frec 6.0 kN

System MQ

HDG
Connector, two dimensional (HDG) ➀
167 MQ-F (HDG):
Frec 5.4 kN
Weight Packaging Ordering Item no.
each (g) contents (pcs) designation Frec 5.0 kN

Stainless Steel
Connector, double, two dimensional 446 10

Medium duty
➀ MQV-2/2D-F 304150

System MQ
Connector, triple, two dimensional 602 10 ➁ MQV-3/2D-F 304152
112

MQ-HDG plus:
Frec 8.1 kN Frec 5.0 kN


167 MQ-F (HDG):
Frec 5.4 kN

System MI
Frec 5.4 kN

HDG
112

MQ-HDG plus:
Frec 8.1 kN Frec 5.4 kN
Fixed points
System MQ

and sliders

Connector, three dimensional (HDG) ➀ 55


➁ 55

Weight Packaging Ordering Item no.


each (g) contents (pcs) designation
Connector, triple, three dimensional 451 10 ➀ MQV-3/3D-F 304153 112

Connector, quadruple, three dimensional 770 10 ➁ MQV-4/3D-F 304154 112


Airconditioning
and Ventilation
System MQ

Longitudinal channel connector (HDG) ➀ ➁


Firestop systems

205
205
45

Weight Packaging Ordering Item no.


each (g) contents (pcs) designation
Channel connector, 12 hole 583 10 ➀ MQV-12-F 304155
Channel connector, 4 hole, flat 188 10 ➁ MQV-P4-F 304156

page 14 page 107


Longitudinal channel connector (HDG) 205
205
45

Weight Packaging Ordering Item no.


each (g) contents (pcs) designation
Channel connector, 12 hole 583 10 ➀ MQV-12-F 304155
System
Channel MQ Hot Dipped
connector, 4 hole,Galvanized
flat 188 10 ➁ MQV-P4-F 304156

Hilti Installation 1_4 10/14/08 6:45 PM Page 101


Connector, flat (HDG) 150
and Technical

Hilti Installation 1_4 10/14/08 6:45 PM Page 101


PC Software
Information

Hilti Installation 1_4 10/14/08 6:45 PM Page 101


Weight Packaging Ordering Item no.
each (g) contents (pcs) designation 95.5

Channel connector, 4 hole, flat T 196 10 MQV-T-F 304157


System MQ Hot Dipped Galvanized

System MQ Hot Dipped Galvanized


System MQ Hot Dipped Galvanized

Channel base /
Medium duty

System MM
Light duty

Base material connector


Channel
Channel basebase //
Base
Features: material
Base material connector
connector 19.4 19

■ Reliable and easy to use.


■ Connection of channels to any base material.
Features: 19
Features:
■ The MQN-F
Reliable andpushbutton
easy to use.can be prefitted.
19.4
3519.4 10 19
Medium duty


System MQ

■ Reliable and easy to use.


■ Connection of channels to any base material.
■ Connection of channels to any base material.
■ The MQN-F pushbutton can be prefitted. 35 10
■ The MQN-F pushbutton can be prefitted. 35 10

Technical data:
Material:
page 100
S 235 JR as per DIN EN 10025
Technical data:
Galvanizing: hot-dip galvanized, min. 56 µm
Hilti Pipe Rings

Technical data:
Material: S 235 JR
Separate design verification of the fastening onasthe
perbase
DINmaterial
EN 10025must
Material: S 235 JR as per DIN EN 10025
be provided.
Galvanizing: hot-dip galvanized, min. 56 µm
Galvanizing: hot-dip galvanized, min. 56 µm
Separate design verification of the fastening on the base material must
Separate design
be provided. verification of the fastening on the base material must
be provided.

Base material connector (HDG) ➀


Medium duty

167
System MQ

112

Base material
Suitable for
connector (HDG)
Weight Packaging Ordering Item no.
HDG

A

Base material451
channel height
connector (HDG)
each (g) contents (pcs) designation 167 Channel
➀ 167 B
MQ-41, MQ-21D 10 ➀ MQV-2/2D-14-F 304151
112 112
112
Frec
Suitable for Weight Packaging Ordering Item no. A
MQ-21,
Suitable
channel for MQ-31, MQ-41
height 110(g)
Weight
each 20 (pcs)
Packaging
contents ➁ MQP-1/1-F
Ordering
designation 304161
Item no. Channel A

MQ-21,
channel
MQ-41, MQ-21DMQ-31, MQ-41
height 190(g)
each
451 20 (pcs)
contents
10 ➂
➀ MQP-1/3-F
designation
MQV-2/2D-14-F 304162
304151
112 Channel
B
B Frec
MQ-41,
MQ-21, MQ-21D 451 MQV-2/2D-14-F 304151
112
MQ-21, MQ-31,
MQ-31, MQ-41
MQ-41 290
110 10
20 ➀

➁ MQP-2/3-F
MQP-1/1-F 304163
304161
Frec

MQ-21,
MQ-21, MQ-31,
MQ-31, MQ-41 110 20 ➁ MQP-1/1-F 304161
Stainless Steel

MQ-41 190 20 ➂ MQP-1/3-F 304162


Medium duty

MQ-21,
MQ-21, MQ-31,
MQ-31, MQ-41 190 20
System MQ

MQ-41 290 10 ➂
➃ MQP-1/3-F
MQP-2/3-F 304162
304163
MQ-21, MQ-31, MQ-41 290 10 ➃ MQP-2/3-F 304163 ➁ ➂

Frec Channel Bolt Push- Tightening torque


➁ ➂
➁ ➂
Item (kN) (B) (A) button MD (Nm) 18x12
3x

MQV-2/2D-14-F F
5.0
rec
MQ-41-F
Channel
Double
Bolt
MQN-F
Push-
40
Tightening torque
14x19

Item 7.8
F(kN)
rec
MQ-41-HDG
Channel
(B) plus Double
Bolt
(A) MQN-F
Push-
button 40
Tightening
M (Nm) torque
D
3x
18x12 59
Item (kN) (B) (A) button M (Nm)
D 61 18x12
80
MQV-2/2D-14-F 5.0 MQ-41-F Double MQN-F 40 118 3x
System MI

14x19
MQV-2/2D-14-F 5.0 MQ-41-F Double MQN-F 40 14x19
61 40

7.8 MQ-41-HDG plus Double MQN-F 40


HDG

59
7.8 MQ-41-HDG plus Double MQN-F 40 ➃ 60
61
61
118 80 59
118 80
61 40
61 40

➃ 60
➃ 60

59
Fixed points
System MQ
and sliders

59
59 11.5 34

11.5 34
11.5 34

Base material connector 45 º (HDG)


Airconditioning
and Ventilation

System MQ

Base
Base material
Suitable for
material
channel height connector
Weight
contents (pcs) 45
Packaging
connector
each (g)
45 º
º (HDG)
Ordering
(HDG)
designation
Item no.

MQ-21, MQ-31, MQ-41 350 10 MQP-45°-F 304164 105


Suitable for Weight Packaging Ordering Item no.
Suitable for
channel height Weight
each (g) Packaging(pcs)
contents Ordering
designation Item no. 45°
channel height each (g) contents (pcs) designation
MQ-21, MQ-31, MQ-41 350 10 MQP-45°-F 304164 105
MQ-21, MQ-31, MQ-41 350 10 MQP-45°-F 304164 14 105
Firestop systems

45°
45°
41 42
14
14

41 42
41 42

page 108
System MQ channel installation hot-dip galvanised System MQ Hot Dipped Galvanized

Channel base (HDG) ➀


A

and Technical
PC Software

Information
105
Suitable for Weight Packaging Ordering Item no.
channel height each (g) contents (pcs) designation
20x14

MQ-21 – MQ-72 1150 12 ➀ MQP-21-72-F 304165 6


Frec

MQ-41D 1880 8 ➁ MQP-82-F 304166 80


135

MQ-52-72D, MQ-124X D 2730 6 ➂ MQP-124-F 304167


185


A A
F Bolt Push- Tightening torque

Medium duty
rec

System MM
(kN) (A) button MD (Nm)

Light duty
106

Item Channel I/III Channel II


MQP-21-72-F 5.0 8.0 Double MQN-F 40 Frec
20x14

MQP-82-F 7.5 11.0 Quadruple MQN-F 40 100


150
200

MQP-124-F 7.5 11.0 Quadruple MQN-F 40


Channel I: MQ-21-F, MQ-41-F, MQ-21D-F, MQ-41D-F ➂
Channel II: MQ-21-HDG plus, MQ-31-HDG plus, MQ-41-HDG plus, MQ-21D-HDG plus, MQ-41D-HDG plus A A

Channel III: MQ-52-F, MQ-72-F, MQ-52-72D-F, MQ-124XD-F


130

Medium duty
System MQ
20x14
Frec
Channel base  firestop tested
8

200
250
100

IBMB no. 3897/1802-5

Hilti Pipe Rings


Pivot base (HDG)
Suitable for Weight Packaging Ordering Item no.
channel height each (g) contents (pcs) designation 152

MQ-21, MQ-31, MQ-41 1055 10 MQP-G-F 304168

Medium duty
System MQ
49

Frec Bolt Push- Tightening torque

HDG
(kN) (A) button MD (Nm) 75
Item Channel I Channel II 75
54 190

MQP-G-F 5.0 8.0 Double MQN-F 40


Channel I: MQ-21-F, MQ-41-F
Channel II: MQ-21-HDG plus, MQ-31-HDG plus, MQ-21D-HDG plus, MQ-41-HDG plus

Stainless Steel
Medium duty
System MQ
System MI
HDG
Fixed points
System MQ

and sliders
Airconditioning
and Ventilation
System MQ

Firestop systems

page 16 page 109


System MQ Hot Dipped Galvanized

page 110
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
System MQ Hot Dipped Galvanized

and Technical
PC Software

Information
Medium duty
System MM
Light duty
Medium duty
System MQ
Hilti Pipe Rings
System MQ channel installation hot-dip galvanised

Accessories
Features:
■ Matching items in programme.

Medium duty
System MQ

HDG
Stainless Steel
Medium duty
System MQ
Technical data:
Galvanising: hot-dip galvanised, min. 56 µm

System MI
HDG
Boss plate (HDG)
52.5
45.5
5
Material: S 235 JR as per DIN EN 10025 9.5
11.5
Thread Weight Packaging Ordering Item no. 13.5
each (g) contents (pcs) designation 17.5

M 8 92 20 MQZ-L9-F 304196
Fixed points
System MQ

and sliders

M10 88 20 ➀ MQZ-L11-F 304197


M12 84 20 ➀ MQZ-L13-F 304198
M16 80 20 ➀ MQZ-L17-F 304199

Boss plates ➀ firestop tested


Airconditioning
and Ventilation
System MQ

IBMB no. 3897/1802-5

Installation washer (HDG) 28


34.2
Firestop systems

Material: S 235 JR as per DIN EN 10025


10.5

Hole diameter Weight Packaging Ordering Item no.


(mm) each (g) contents (pcs) designation
10,5 30 40 MQZ-U-F 304208

page 111
Adaptor (HDG)
System
System MQ
MQ Hot
Hot Dipped Galvanized
Dipped Galvanized

Channel tie (HDG) ➀ ➁


and Technical
PC Software
Information

For accurate use-assembled double channels


Material: S 235 JR as per DIN EN 10025

Connection Width across Weight Packaging Ordering Item no.


Hilti Installation 1_4 thread
10/14/08 flats (mm)
6:45 PM each (g) 117 contents (pcs)
Page designation
Channel tie M8 13 23 40 ➀ MQZ-SV-F 304206
Locking device M10 13 25 40 ➁ MQZ-SS-F 304207
Medium duty

System MM
Light duty

Rec. tensile load, Rec. shear load, Tightening torque


Item Zrec (kN) Qrec (kN) MD (Nm)
System MQ Hot Dipped Galvanized
MQZ-SV-F 1.0 – 6
MQZ-SS-F 3.0 5.0 20
Medium duty
System MQ

Channel
Pipe ringsendcap
accessories
➀ d ➁
40 11 x 18
Made of polypropylene (PP), suitable for all installation channels. 31
21
Base
channel height plate MGS 2-
Suitable for Weight
1
/2″- FPackaging
each (g) (HDG)
contents (pcs.)
Ordering
designation
Item no. 4
MQ-21, MQ-21DS235 JRG2C
Material: 2 50 ➀ MQZ-E21 370598 H
MQ-31 85
hot-dip galvanized,2min. 45 µm50 ➁ MQZ-E31 369686
Hilti Pipe Rings

Type: ➂
MQ-41, MQ-41D 2 50 ➂ MQZ-E41 369685 120
d H Fz rec Packaging Ordering Item no.
[Inch] [mm] [kN] contents (pcs) designation
1
⁄2" 19 5.0 10 MGS 2-1⁄2-F 202842 41.3

The means of fastening to the base material, e.g. anchors, requires separate verification.
Medium duty

d
System MQ

Base plate MGM 2-F (HDG) axb


HDG

Material: S235 JRG2C


Type: hot-dip galvanized, min. 45 µm
H 4
d H axb Fz rec Packaging Ordering Item no.
[mm /Inch] [mm] [mm] [kN] contents (pcs) designation 85
120 40
M16" 20 13x18 8.2 10 MGM 2-16-F 202839
Stainless Steel

3
⁄4" 21 13x18 8.2 10 MGM 2-3⁄4"-F 202840
Medium duty
System MQ

1" 25 13x18 8.2 10 MGM 2-1"-F 202841


The means of fastening to the base material, e.g. anchors, requires separate verification.

d
Base plate MFP-GP 16-F (HDG) H
∅a
Material: S 235 JR as per DIN EN 10025
System MI

Type: hot-dip galvanized, min. 45 µm


HDG

Connection Dimensions Max. load Shear load for Packaging Ordering Item no.
boss H a Frec (A = 150 mm) contents (pcs) designation 109
d [mm] [mm] [kN] [kN]
150 100
M16 20 13.5 15.0 2.0 25 MFP-GP 16-F 304279
The means of fastening to the base material, e.g. anchors, requires separate verification.
Fixed points
System MQ
and sliders

Threaded pipe GR-G-F (HDG)


Type: rolled thread, hot-dip galvanized, 45 µm
Inch Length Packaging Ordering Item no. M L
size L [mm] contents (pcs) designation
Airconditioning
and Ventilation

/4″
3
1000 5 GR-G /4″-F 1 m
3
304781
System MQ

1″ 1000 5 GR-G 1″-F 1 m 304782

Adaptor MQZ-A-F (HDG) 3/4"


1"
Suitable for MP-MXI-F / MP-MX-F pipe rings with M16 connection
Firestop systems

and MFP-GP 16-F base plate


Type: hot-dip galvanized, 45 µm
47.5
Internal External Width across Weight Packaging Ordering Item no.
thread thread flats [mm] each (g) contents (pcs) designation 16
M16
/4″
3
M16 30 140 25 MQZ-A-3/4″/M16-F 304204
1″ M16 36 180 25 MQZ-A-1″/M16-F 304205
page 106
page 112
System MQ Hot Dipped Galvanized

Angle

and Technical
MP-MQE-W-F

PC Software

Information
Medium duty
System MM
Light duty
Medium duty
System MQ
Applications Technical data
nn 90° connection of MQ hot-dip galvanized channels
MP-MQE-W-F
nn Universal: few parts for a wide range of applications
Material composition S235JR as per DIN EN 10025
nn Medium-duty load range
Surface Finish Hot dip galvanized 56 µm

Hilti Pipe Rings


Additional product information Use with 2pc. wing nuts MQM-
Advantages M10 HDG plus and 2pc. bolts
nn Reliable and easy to use M10x25-F grade 8.8
nn Quick installation without welding
nn Hot-dip galvanized

Medium duty
System MQ
1
04) +'*  2


HDG
 )UHF N1 )UHF N1 






Stainless Steel
Medium duty
System MQ
04+'*SOXV
)UHF N1 )UHF N1

3
04) +'* 

System MI

)UHF N1 )UHF N1

HDG



Fixed points
System MQ

and sliders

04+'*SOXV
)UHF N1 )UHF N1

Order designation Weight Thickness Tightening torque Sales Quantity Item Number
Airconditioning
and Ventilation
System MQ

1 2-hole angle MP-MQE-W2-F 94 g 3 mm 40 Nm 20 PC 02022808


2 2-hole angle MP-MQE-WP2-F 133 g 4 mm 40 Nm 10 PC 02022809
3 4-hole angle MP-MQE-W4-F 324 g 4 mm 40 Nm 10 PC 02022890
Firestop systems

page 113
System MQ Hot Dipped Galvanized

Rail support
and Technical

MP-MQE-P-F
PC Software
Information
Medium duty

System MM
Light duty
Medium duty
System MQ

Applications Technical data


nn Connection of MQ hot-dip galvanized channels to any base
material MP-MQE-P-F

nn Medium- to heavy-duty load range Material composition S235JR as per DIN EN 10025
Surface Finish Hot dip galvanized 56 µm
Hilti Pipe Rings

Advantages Additional product information Use with 2pc. wing nuts


MQM-M10 HDG plus and 2pc.
nn Reliable and easy to use bolts M10x25-F grade 8.8
nn Quick installation without welding
nn Hot-dip galvanized
Medium duty
System MQ

04) +'* 
HDG

 )UHF N1


$

Stainless Steel
Medium duty

[
System MQ



 04+'*SOXV
 )UHF N1

Order designation Weight Thickness Tightening torque Sales Quantity Item Number
System MI

Rail support MP-MQE-P-21-72-F 979 g 4 mm 40 Nm 12 PC 02022891


HDG
Fixed points
System MQ
and sliders
Airconditioning
and Ventilation

System MQ
Firestop systems

page 114
System
Moving MQ Hot hot-dip
components Dippedgalvanised
Galvanized

MRG-F roll connector

and Technical
PC Software

Information
Features:
■ For use suspended or standing without conversion
■ Coordinated loading classes suitable for Hilti pipe rings
■ Temperature resistant up to 300°C as no parts are of plastic.
■ Stiffened base plate suitable for MQ channel installation system
■ Slide can not pull out.

Medium duty
System MM
Light duty
Smooth rolling on coated rollers. Large movement: MRG 2-F up to
Technical data: Coefficient of friction: µ0=0.15 80 mm, MRG-D6-F up to 116 mm.
Galvanising: hot-dip galvanised, min. 45 µm Center mark for setting to zero.
Delivery without nut, washer or bolt

Medium duty
11,5 x 20

System MQ
MRG 2-F roll connector (HDG) MRG 2-F

One connection boss 80


Connection boss/ Frec Max. displacement Max. displacement Packaging Ordering Item no.
double thread (kN) axial (mm) transverse (mm) contents (pcs) designation
M10 / M12 1.5 80 – 5 MRG 2-F 304213

Hilti Pipe Rings


Roll connector MRG 2-R firestop tested

IBMB no. 3897/1802-5

Medium duty
System MQ
MRG-D6-F double roll connector (HDG)

HDG
Two connection bosses 90
Connection boss/ Frec Max. displacement Max. displacement Packaging Ordering Item no.
double thread (kN) axial (mm) transverse (mm) contents (pcs) designation
13,5 x 20
M12 / M16 6.0 116 – 5 MRG-D6-F 304214

Stainless Steel
MRG-D6-F mm mm

Medium duty
System MQ
58 16
n ± nt 1
ctio e
e fle cem
d la
x. isp
ma ax. d
m 159

System MI
219

HDG
Fixed points
System MQ

and sliders
Airconditioning
and Ventilation
System MQ

Firestop systems

page
page115
23
System MQ Hot Dipped Galvanized Fixed points hot-dip galvanised

MFP-F heavy-duty fixed point


and Technical
PC Software
Information

MFP-F fixed point pipe ring (HDG)


M20

S M16

Material: S 235 JR as per DIN EN 10025


Galvanising: hot-dip galvanised, min. 45 µm D
Hexagon bolt: grade 8.8-HDG
B
Tightening torque: 80 Nm 90 mm
Medium duty

System MM
Light duty

If the force at the fixed point is greater than 10 kN, weld stops on the bracing side of the pipe.
Pipe size Dimensions Packaging Ordering Item no.
(mm) (inch) D [mm] S [mm] B [mm] contents (pcs) designation
100 108-112 8 231.4 6 MFP-NW 100 M20-F 304241
4″ 110-115 8 234.6 6 MFP-4″ M20-F 304242
125/127 125-127 8 245.1 6 MFP-NW 125/127 M20-F 304243
125 5″ 133-140 8 262.0 6 MFP-125 M20-F 304244
Medium duty
System MQ

150 158-162 8 282.5 6 MFP-NW 150 M20-F 304245


6″ 165-169 8 299.8 6 MFP-6″ M20-F 304246
193/200 193-200 8 322.4 6 MFP-193/200 M20-F 304247
200 8″ 219 8 342.8 6 MFP-NW 200 M20-F 304248
244/250 244-250 8 373.9 3 MFP-244/250 M20-F 304249
250 267-273 8 397.6 2 MFP-NW 250 M20-F 304250
Hilti Pipe Rings

Fixed point support (HDG)


Type: rolled thread, hot-dip galvanised, 45 µm
Inch Packaging Ordering Item no.
size contents (pcs) designation M L
1 /4″
1
5 GR-G 1 /4″-F 1m
1
304783
Medium duty
System MQ
HDG

Threaded rod (HDG)


Material threaded rod: DIN 267-10, grade 4.6, ISO-metric
Type: rolled thread, hot-dip galvanised, 45 µm
Stainless Steel

M L
Medium duty
System MQ

Thread Packaging Ordering Item no.


size contents (pcs) designation
M16 10 AM16-F 1m 304776
M16 10 AM16-F 2m 304777
System MI
HDG
Fixed points
System MQ
and sliders
Airconditioning
and Ventilation

System MQ
Firestop systems

page 116 page 25


Fixedpoints
Fixed pointshot-dip
hot-dipgalvanised
galvanised System MQ Hot Dipped Galvanized

MFP 1-F
MFP 1-F fixed
fixed point
point set
set (HDG)
(HDG) MFP-NW…-F
MFP-NW…-F

and Technical
PC Software

Information
hot-dipgalvanised,
hot-dip galvanised,min.
min.45
45µm
µm HST-RM12
HST-R M12
uptotoFFrecrec33kN
up kN Bracingset
Bracing set

Ordering
Ordering Packaging
Packaging Itemno.
Item no.
designation
designation contents(pcs)
contents (pcs) 1 11/41"-F
/4"-F

asper
ringas
MFP-F-pipring
MFP-F-pip perdesired
desiredpipe
pipesize
size MM16-F
16-F
MFP-BP20-F
MFP-BP 20-F
MFP-BP20-F
MFP-BP basicset
20-Fbasic set 11 304252
304252 HH

MFP-AP bracingset
1-Fbracing
MFP-AP1-F set 11 304253
304253 HST-RM16
HST-R M16
AM16-F
AM 16-F

Medium duty
System MM
MM20-F
20-F

Light duty
DD
ireirct
ectioio
n nofofo
f fo
rcrc
ee
Fre
Fre cc

MFP-AP1-F
MFP-AP 1-F

(totop
(to topside
sideofofpipe)
pipe) M16-F
M16-F
HHminmin ==170
170mmmm (80Nm)
(80 Nm)

HHmaxmax==1200
1200mm mm

Medium duty
System MQ
MFP 1a-F
MFP 1a-F fixed
fixed point
point set
set (HDG)
(HDG) MFP-NW…-F
MFP-NW…-F
HST-RM12
HST-R M12
hot-dipgalvanised,
hot-dip galvanised,min.
min.45
45µm
µm
uptotoFFrecrec33kN
up kNwithout
withoutbracing
bracing
Ordering
Ordering Packaging
Packaging Itemno.
Item no.

Hilti Pipe Rings


111/14/"-F
4"-F
designation
designation contents(pcs)
contents (pcs)
HH
MFP-Fpipe
MFP-F asper
ringas
pipering perdesired
desiredpipe
pipesize
size MFP-BP20-F
MFP-BP 20-F
MFP-BP20-F
MFP-BP basicset
20-Fbasic set 11 304252
304252
M20-F
M20-F
44
Frec [kN]
Frec [kN]

FF
rere
cc
22
(totop
(to topside
sideofofpipe)
pipe)
00 HHminmin ==140
140mmmm

Medium duty
M16-F
M16-F

System MQ
HHmaxmax==800
800mmmm
140
200

300

400

500

600

700

800
140
200

300

400

500

600

700

800

(80Nm)
(80 Nm)

HDG
Supportheight
Support heightHH[mm]
[mm]

MFP 2-F
MFP 2-F fixed
fixed point
point set
set (HDG)
(HDG) MFP-NW…-F
MFP-NW…-F
(internationalversion)
(international version)

Stainless Steel
HST-RM12
HST-R M12

Medium duty
System MQ
hot-dipgalvanised,
hot-dip galvanised,min.
min.45
45µm
µm MM16-F
16-F

up 10kN
uptotoFFrecrec10 kN HH
/4"-F
1 11/41"-F

Ordering
Ordering Packaging
Packaging Itemno.
Item no.
designation
designation contents(pcs)
contents (pcs)
HST-RM16
HST-R M16
AM16-F
AM 16-F MFP-BP20-F
MFP-BP 20-F
MFP-Fpipe asper
ringas
pipering perdesired
desiredpipe
pipesize
size
MM20-F
20-F
MFP-F Dire
Dire ctn
ctio ion
Fre
ofof
Fre
fofo
rcrc
ee

basicset
set 11
cc
MFP-BP 20-Fbasic
MFP-BP20-F 304252
304252
MFP-AP2-F
MFP-AP bracingset
2-Fbracing set 11 376022
376022

System MI
MM16-F
16-F
(80Nm)
(80 Nm)

MFP-AP2-F
MFP-AP 2-F

HDG
(totop
(to topside
sideofofpipe)
pipe)
HHminmin ==140
140mmmm
HHmaxmax==1200
1200mm mm
Fixed points
System MQ

and sliders

MFP 3-F
MFP 3-F fixed
fixed point
point set
set (HDG)
(HDG) (inter-
(inter- HST-RM12
HST-R M12
MFP-NW…-F
MFP-NW…-F
nationalversion)
national version)
hot-dipgalvanised,
hot-dip galvanised,min.
min.45
45µm
µm "-F
11141"4-F
uptotoFFrecrec20
up 20kN
kN HH
Airconditioning
and Ventilation

Ordering Packaging Itemno.


no. HST-RM20
HST-R M20
Ordering Packaging Item
MFP-BP16-F
MFP-BP 16-F
System MQ

AM16-F
AM16-F
designation
designation contents(pcs)
contents (pcs)
DD
ireirct
MFP-Fpipe
MFP-F asper
ringas
pipering perdesired
desiredpipe
pipesize
size ectioio
n nofofo
Fre
Fre
f fo
rcrc
ee
basicset
MFP-BP16-Fbasic
MFP-BP16-F set 11 304255
304255
cc

MFP-AP3-F
MFP-AP bracingset
3-Fbracing set 11 304257
304257
Heightadjustment
Height adjustment
sleeve
sleeve M16-F
M16-F
(withcheck
(with checkbore)
bore)
Givenloads
Given loadsonly
onlyapply
applyififHilti
HiltiHST-R
HST-Ranchors
anchorsare
areused.
used. (80Nm)
(80 Nm)
MFP-AP3-F
MFP-AP 3-F
Firestop systems

IfIfthe
thedirection
directionofofforce
forceisisnot
notknown,
known,ororchanging,
changing,the
thefixed
fixedpoint
pointmust
mustbe
be
bracedon
braced onboth
bothsides.
sides. (topipe
(to pipecentreline)
centreline)
IfIfthe
theforce
forceatatthe
thefixed
fixedpoint
pointisisgreater
greaterthan
than10
10kN,
kN,weld
weldstops
stopson
onthe
the HHminmin ==140
140mm
mm
bracingside
bracing sideofofthe
thepipe
pipe HHmaxmax==1200
1200mm
mm

page26
page 26 page 117
System MQhot-dip
Pipe rings Hot Dipped Galvanized
galvanised

MP-MI/-M hot-dip galvanized


and Technical
PC Software

For installations exposed to moderate corrosiveness


Information

Use:
■ In humid inside rooms (moderate condensation)
■ Outside in medium-corrosive surroundings

Benefits:
■ Solid welded-on connection boss.
Medium duty

System MM

■ Pipe ring hoops swaged for greater stiffness.


Light duty

■ Clamping screws secured against loss


■ Good resistance to corrosion (HDG 45 µm).

Technical data:
Max. static load recommended for suspensions:
MP-MI-F / -M-F 1/2″ up to 3″ diameter Frec = 3000N
Medium duty
System MQ

Pipe ring material: S 235 JR steel as per DIN EN 10025


Galvanising: 45 µm
Clamping screws: M8 with combination
socket and separate nut
Rubber inlay material: EPDM
Temperature resistance: –50° C to + 120° C
Hilti Pipe Rings

Shore A hardness ( DIN 53 505) 50° ± 5° Acoustic Building


material class
insulation
Noise reduction: LA = 18 dB (A) for DIN 4109 B2
„Normal flammability“
Stability: aging, ozone, weather inspected as per DIN 4102

and hot water


Firestop
M10
s b1 SW 17
h
D
10
Medium duty
System MQ
HDG

b
Stainless Steel
Medium duty
System MQ

MP-MI-F (HDG)
Hot-dip galvanised pipe ring with metric connection boss and insulating inlay as per DIN 4109
Size Clamping Connection thread/ Clamping Dimensions Packaging Ordering Item no.
[mm/inch] range width across flats bolts B [mm] bxs [mm] h [mm] b1 [mm] contents (pcs) designation
D (mm)
/2″
1
20-25 M10/SW17 M8 69 24x2 28 21 25 MP-MI-F 1/2″ M10 304258
3
/4″ 25-30 M10/SW17 M8 75 24x2 30 21 25 MP-MI-F 3/4″ M10 304259
System MI

1″ 32-38 M10/SW17 M8 83 24x2 34 21 25 MP-MI-F 1″ M10 304260


HDG

1 1/4″ 40-45 M10/SW17 M8 92 24x2 38 21 25 MP-MI-F 11/4″ M10 304261


1 1/2″ 48-54 M10/SW17 M8 101 24x2 42 21 25 MP-MI-F 11/2″ M10 304262
54/57 54-57 M10/SW17 M8 107 24x2 47 21 10 MP-MI-F 54/57 M10 304263
2″ 57-64 M10/SW17 M8 111 24x2 48 21 10 MP-MI-F 2″ M10 304264
68/72 68-72 M10/SW17 M8 123 24x2 54 21 10 MP-MI-F 68/72 M10 304265
2 1/2″ 70-77 M10/SW17 M8 130 24x2 51 21 10 MP-MI-F 21/2″ M10 304266
Fixed points
System MQ

78/84 M10/SW17 M8 139 24x2 58 21 10


and sliders

78-84 MP-MI-F 78/84 M10 304267


3″ 82-90 M10/SW17 M8 144 24x2 57 21 10 MP-MI-F 3″ M10 304268

*Version without acoustic insulation is also available


MP-M-F (HDG)
Hot-dip galvanised pipe ring with metric connection boss without insulating inlay
Airconditioning
and Ventilation

System MQ

Size Clamping Connection thread/ Clamping Dimensions Packaging Ordering Item no.
[mm/inch] range width across flats bolts B [mm] bxs [mm] h [mm] b1 [mm] contents (pcs) designation
D (mm)
/2″
1
20-25 M10/SW17 M8 69 24x2 25 21 25 MP-M-F 1
/2″ M10 304269
3
/4″ 25-30 M10/SW17 M8 75 24x2 28 21 25 MP-M-F 3
/4″ M10 304270
1″ 32-38 M10/SW17 M8 83 24x2 32 21 25 MP-M-F 1″ M10 304271
11/4″ 40-45 M10/SW17 M8 92 24x2 35 21 25 MP-M-F 11/4″ M10 304272
11/2″ 48-54 M10/SW17 M8 101 24x2 39 21 25 MP-M-F 11/2″ M10 304273
Firestop systems

54/57 54-57 M10/SW17 M8 107 24x2 44 21 10 MP-M-F 54/57 M10 304274


2″ 57-64 M10/SW17 M8 111 24x2 45 21 10 MP-M-F 2″ M10 304275
68/72 68-72 M10/SW17 M8 123 24x2 51 21 10 MP-M-F 68/72 M10 304276
21/2″ 70-77 M10/SW17 M8 130 24x2 50 21 10 MP-M-F 21/2″ M10 304277
3″ 82-90 M10/SW17 M8 144 24x2 55 21 10 MP-M-F 3″ M10 304278

page 118
page 28
System MQrings
Pipe Hot hot-dip
Dippedgalvanised
Galvanized

MP-MXI-F pipe ring

and Technical
PC Software

Information
for „extra“ heavy duty installations exposed to moderate corrosiveness

Fields of applications:
■ Industrial pipe fitting
■ Mechanical installations
■ Process and control lines
■ heavy-duty pipe runs

Medium duty
System MM
Light duty
Benefits:
■ Solid connection boss, welded all round
■ Strong clamping bolts for high loads
■ Non-slip, pre-fitted profiled rubber inlay
■ Suitable for the installation of pipes under dynamic loading if used
with vibration damping components.

Medium duty
System MQ
Technical data:
Max permissible load for suspensions:
up to 3″ max. Frec = 6000 N
Acoustic Building
from 4″ up to 274 mm diameter max. Frec = 10000 N insulation material class
B2

s
from 324 up to 406 mm diameter max. Frec = 15000 N

ice
for DIN 4109

Hilti Pipe Rings


SHOCK

erv
„Normal flammability“

S
from 457 up to 508 mm diameter max. Frec = 17000 N inspected TESTED

ce
as per DIN 4102

fen
De
Pipe ring material: STW 22 steel as per DIN EN 10111 (HDG 45 µm)
AC Laboratory, Spiez

Firestop
Rubber inlay material: EPDM
Temperature resistance: –50°C to +120°C
Shore A hardness: 50° ± 5° Shore-A
Noise reduction: Δ LA = 16 dB (A)

Medium duty
System MQ

HDG
Recommended guide values for dynamic loading
of MP-MXI-F/MP-MX-F
M16 connection boss, 3
/4″ connection boss, 1″ connection boss,
(max. Frec 6000 N) (max. Frec 10000 N) (max. Frec 10000 N)

Stainless Steel
Medium duty
System MQ
from pipe size 4″ (108 mm) up to 274 mm from pipe size 2″ (60 mm) up to 133 mm from pipe size 5″ (137 mm) up to 274 mm
δ L L L L L L δ L L L L L L δ L L L L L L
mm 100 mm 200 mm 300 mm 400 mm 500 mm 1000 mm mm 100 mm 200 mm 300 mm 400 mm 500 mm 1000 mm mm 100 mm 200 mm 300 mm 400 mm 500 mm 1000 mm
0.5 ● ● ● ● ● ● 0.5 ● ● ● ● ● ● 0.5 ● ● ● ● ● ●
1 – ● ● ● ● ● 1 – ● ● ● ● ● 1 – ● ● ● ● ●
1.5 – ● ● ● ● ● 1.5 – ● ● ● ● ● 1.5 – ● ● ● ● ●
2 – ● ● ● ● ● 2 – – ● ● ● ● 2 – – ● ● ● ●
4 – – ● ● ● ● 4 – – – ● ● ● 4 – – – ● ● ●

System MI
6* – – – – ●* ● 6 – – – – ● ● 6 – – – – ● ●

HDG
8 – – – – ● ● 8 – – – – ● ● 8 – – – – ● ●
10 – – – – ● 10 – – – – – ● 10 – – – – ●
The determined values apply only if the The determined values apply only if the The determined values apply only if the
MFP-GP16-F base plate and M16 threaded MFP-GP 3/4″-F base plate and GR-G 3/4″-F MFP-GP1″-F base plate and GR-G1″-F
rod of the 8.8 grade are used. threaded pipe are used. threaded pipe are used.
Fixed points
System MQ

and sliders

● Fatigue strength (2×106 load cycles) as per the S-N curve.

L
* Example: Is the shown pipe fastening resistant to dynamic fatigue stressing?
Airconditioning
and Ventilation
System MQ

Demand: Known: Threaded base plate with M16 connection and anchor approved for
tension zone. Distance between and ceiling or wall, L, 1500 mm.
Max. side movement caused by vibration, δ, in mm = 6 mm.
Result: Resistant to fatigue stressing (2×106 load cycles) allowing for dimension
L = min. 500 mm.
Firestop systems

page
page119
29
System MQhot-dip
Pipe rings Hot Dipped Galvanized
galvanised

MP-MXI-F (HDG)
and Technical
PC Software

Pipe ring with metric connection boss and insulating inlay as per DIN 4109
Information

M16 M10/M12
h

20

23
M 10

B
Medium duty

System MM

b
Light duty

Size Clamping range Connection Clamping Dimensions Packaging Ordering Item no.
[mm/inch] d [mm] thread bolts B [mm] s×b [mm] h [mm] contents (pcs) designation
2″ 60– 65 M10/M12 M10 142 3×30 64 25 MP-MXI-F 2″ M10/M12 374897
21/2″ 73– 78 M10/M12 M10 156 3×30 71 25 MP-MXI-F 21/2″ M10/M12 374898
3″ 88– 93 M10/M12 M10 172 3×30 78 25 MP-MXI-F 3″ M10/M12 374899
4″ 108–116 M16 M12 210 4×40 90 25 MP-MXI-F 4″ M16 374900
125 122–126 M16 M12 221 4×40 95 25 MP-MXI-F 125 M16 374901
Medium duty
System MQ

133 131–137 M16 M12 231 4×40 100 10 MP-MXI-F 133 M16 374902
5″ 139–144 M16 M12 238 4×40 104 10 MP-MXI-F 5″ M16 374903
159 159–166 M16 M12 261 4×40 115 10 MP-MXI-F 159 M16 374904
6″ 163–170 M16 M12 265 4×40 117 10 MP-MXI-F 6″ M16 374905
177,8 177–182 M16 M16 284 4×40 123 10 MP-MXI-F 177,8 M16 374906
193,7 192–200 M16 M16 303 4×40 132 10 MP-MXI-F 193,7 M16 374907
210 210–218 M16 M16 321 4×40 141 10 MP-MXI-F 210 M16 374908
Hilti Pipe Rings

219 219–228 M16 M16 330 4×40 146 10 MP-MXI-F 219 M16 374909
244,5 244–253 M16 M16 355 4×40 158 10 MP-MXI-F 244,5 M16 374910
267/274 267–274 M16 M16 375 4×40 167 10 MP-MXI-F 267/274 M16 374911
275 275–282 M16 M16 384 4×40 173 10 MP-MXI-F 275 M16 374912
324 315–324 M16 M16 441 5×50 190 1 MP-MXI-F 324 M16 374913
326 325–330 M16 M16 445 5×50 192 1 MP-MXI-F 326 M16 374914
355 348–356 M16 M16 471 5×50 205 1 MP-MXI-F 355 M16 374915
368 364–372 M16 M16 488 5×50 213 1 MP-MXI-F 368 M16 374916
Medium duty
System MQ

406 400–409 M16 M16 525 5×50 232 1 MP-MXI-F 406 M16 374917
HDG

457 454–462 M16 M16 586 6×70 259 1 MP-MXI-F 457 M16 374918
508 500–508 M16 M16 632 6×70 282 1 MP-MXI-F 508 M16 374919

*Version without acoustic insulation is also available


MP-MX-F (HDG)
Stainless Steel

Pipe ring with metric connection boss without insulating inlay


Medium duty
System MQ

h
M16 M10/M12
S 20

23
M 10

B
System MI

Size Clamping range Connection Clamping Dimensions Packaging Ordering Item no.
HDG

[mm/inch] d [mm] thread bolts B [mm] s×b [mm] h [mm] contents (pcs) designation
2″ 60– 65 M10/M12 M10 132 3×30 60 25 MP-MX-F 2″ M10/M12* 374943
21/2″ 73– 78 M10/M12 M10 146 3×30 67 25 MP-MX-F 21/2″ M10/M12* 374944
3″ 88– 93 M10/M12 M10 161 3×30 74 25 MP-MX-F 3″ M10/M12* 374945
4″ 108–116 M16 M12 198 4×40 84 25 MP-MX-F 4″ M16* 374946
125 122–128 M16 M12 210 4×40 89 25 MP-MX-F 125 M16* 374947
Fixed points
System MQ
and sliders

133 132–138 M16 M12 221 4×40 94 10 MP-MX-F 133 M16* 374948
5″ 139–144 M16 M12 226 4×40 98 10 MP-MX-F 5″ M16* 374949
159 159–166 M16 M12 249 4×40 109 10 MP-MX-F 159 M16* 374950
6″ 163–170 M16 M12 253 4×40 111 10 MP-MX-F 6″ M16* 374951
177,8 177–182 M16 M16 272 4×40 117 10 MP-MX-F 177,8 M16* 374952
193,7 192–200 M16 M16 290 4×40 126 10 MP-MX-F 193,7 M16* 374953
210 210–218 M16 M16 309 4×40 135 10 MP-MX-F 210 M16* 374954
Airconditioning
and Ventilation

219 219–228 M16 M16 318 4×40 140 10 MP-MX-F 219 M16* 374955
System MQ

244,5 244–253 M16 M16 343 4×40 152 10 MP-MX-F 244,5 M16* 374956
267/274 267–274 M16 M16 363 4×40 162 10 MP-MX-F 267/274 M16* 374957
275 275–282 M16 M16 372 4×40 167 10 MP-MX-F 275 M16* 374958
324 315–324 M16 M16 429 5×50 184 1 MP-MX-F 324 M16* 374959
326 325–330 M16 M16 433 5×50 186 1 MP-MX-F 326 M16* 374960
355 348–356 M16 M16 460 5×50 199 1 MP-MX-F 355 M16* 374961
Firestop systems

368 364–372 M16 M16 476 5×50 207 1 MP-MX-F 368 M16* 374962
406 400–409 M16 M16 514 5×50 226 1 MP-MX-F 406 M16* 374963
457 454–462 M16 M16 574 6×70 253 1 MP-MX-F 457 M16* 374964
508 500–508 M16 M16 620 6×70 276 1 MP-MX-F 508 M16* 374965
* Available on request

page 120
page 30
System MQ Hot Dipped Galvanized

Threaded rod

and Technical
PC Software

Information
Technical data

Surface Finish Hot dip galvanized


Material composition Steel grade 4.8
Additional product information According DIN 976-1 / Form A

Medium duty
System MM
Light duty
Ordering
Thread diameter Length Order designation Sales Quantity Item Number

M10 1m Threaded rod AM10x1000-F 4.8 20 pc 00304773


M10 2m Threaded rod AM10x2000-F 4.8 20 pc 00414784
M12 1m Threaded rod AM12x1000-F 4.8 15 pc 00304774

Medium duty
System MQ
M12 2m Threaded rod AM12x2000-F 4.8 15 pc 00304775
M16 2m Threaded rod AM16x2000-F 4.8 5 pc 00304777
M20 2m Threaded rod AM20x2000-F 4.8 5 pc 00304779

Hilti Pipe Rings


Threaded pipe
GR-G

Technical data

Medium duty
System MQ
GR-G

HDG
Surface Finish Hot dip galvanized
Material composition Steel grade 4.6
Additional product information Pipe (semi-finished product):
DIN 2440/78

Stainless Steel
Medium duty
System MQ
Ordering
Thread diameter Length Order designation Sales Quantity Item Number

1-1/4 in 1m Threaded pipe GR-G 1 1/4”x1000-F 4.6 5 pc 00304783

System MI
HDG
Hexagon screw Fixed points
System MQ

and sliders

Technical data

Surface Finish Hot dip galvanized


Material composition Steel grade 8.8
Airconditioning

Additional product information According DIN 933


and Ventilation
System MQ

Ordering
Thread diameter Thread length Wrench size Order designation Sales Quantity Item Number

M8 25 mm 13 mm Hexagon screw M8x25-F 100 pc 00304787


M10 25 mm 17 mm Hexagon screw M10x25-F 100 pc 00304788
Firestop systems

M12 25 mm 19 mm Hexagon screw M12x25-F 50 pc 00304789


M12 30 mm 19 mm Hexagon screw M12x30-F 50 pc 00284387
M16 30 mm 24 mm Hexagon screw M16x30-F 25 pc 00304790

page 121
System MQ Hot Dipped Galvanized

Hexagon nut
and Technical
PC Software
Information

Technical data

Surface Finish Hot dip galvanized


Material composition Steel grade 8
Medium duty

Additional product information


System MM

According DIN 934


Light duty

Ordering
Thread diameter Wrench size Order designation Sales Quantity Item Number

M8 13 mm Hexagon nut M8-F 100 pc 00304764


M10 17 mm Hexagon nut M10-F 100 pc 00304765
Medium duty
System MQ

M12 19 mm Hexagon nut M12-F 100 pc 00304766


M16 24 mm Hexagon nut M16-F 50 pc 00304767
M20 30 mm Hexagon nut M20-F 50 pc 00304768

Flat washer
Hilti Pipe Rings

Technical data

Surface Finish Hot dip galvanized


Material composition Steel 140 HV
Medium duty
System MQ

Additional product information According DIN 125 / Form A


HDG

Ordering
Inside diameter Outside Thickness Additional product information Order designation Sales Quantity Item Number
diameter

8.4 mm 16 mm 1.6 mm According DIN 125 / Form A Flat washer A 8,4/16-F 100 pc 00304769
Stainless Steel
Medium duty
System MQ

10.5 mm 20 mm 2 mm According DIN 125 / Form A Flat washer A 10,5/20-F 100 pc 00304770
13 mm 24 mm 2.5 mm According DIN 125 / Form A Flat washer A 13/24-F 100 pc 00304771
17 mm 30 mm 3 mm According DIN 125 / Form A Flat washer A 17/30-F 100 pc 00304772
System MI
HDG

Round threaded rod coupling


Fixed points
System MQ
and sliders

Technical data

Surface Finish Hot dip galvanized


Material composition Grade 8.8, ISO-metric
Airconditioning
and Ventilation

System MQ

Ordering
Thread diameter Length Order designation Sales Quantity Item Number

M8 25 mm Spacer coupling M8x25-F 50 pc 00304791


M10 30 mm Spacer coupling M10x30-F 50 pc 00304792
M12 40 mm Spacer coupling M12x40-F 50 pc 00304793
Firestop systems

M16 50 mm Spacer coupling M16x50-F 20 pc 00304794

page 122
System MQ Channel Installation
Stainless Steel
Hilti. Outperform. Outlast.
System MQ Stainless Steel

Description Pages

Technical data 126-128

Installation channels - Single and Double (Stainless steel) 129

Brackets 130

Pushbutton, Wing nut and Pipe ring saddles 131-132

Channel connectors 133

Channel base connectors 134

Beam clamps 135-136

Channel Accessories 137

Pipe rings (Stainless steel) 138-140

Accessories (Stainless steel) (Threaded rods, nuts,


141-142
washers etc.)

page 125
System
SystemMQ
MQ Stainless Steel
channel installation stainless steel

Technical data Channel sections (stainless steel)


and Technical
PC Software
Information

2.5
Definition of axes

82.6
2

52
2

41.2
F F

41.3
20.6
e2 e1 41.3 41.3
41.3 41.3 41.3
y-axis
e1 e2
"open" z-axis

MQ-21-RA2 MQ-21-R MQ-41-RA2 MQ-41-R MQ-52-R MQ-21D-RA2 MQ-21D-R MQ-41D-R


Medium duty

System MM
Light duty

Channel wall thickness t [mm] 2.0 2.0 2.0 2.0 2.5 2.0 2.0 2.0
Cross-sectional area A [mm2] 165.3 165.3 245.1 245.1 352.1 330.6 330.6 490.3
Channel weight [kg/m] 1.45 1.47 2.09 2.12 3.00 2.92 2.96 4.27
Delivered length [m] 3/6 3/6 3/6 3/6 3/6 3/6 3/6 3/6
Material
Permissible stress σperm. [N/mm2] 142.9 155.8 142.9 155.8 155.8 142.9 155.8 155.8
Stainless steel A2 (1.4301) ● ● ●
Medium duty
System MQ

Stainless steel A5 (1.4571) ● ● ● ● ●


Cross-section values
Y-axis
Axis of gravity "open" 1) e1 [mm] 10.84 10.84 21.13 21.13 26.67 20.60 20.60 41.30
Axis of gravity e2 [mm] 9.76 9.76 20.17 20.17 25.33 20.60 20.60 41.30
Moment of inertia Iy [cm4] 0.92 0.92 5.37 5.37 11.41 4.98 4.98 30.69
Hilti Pipe Rings

Section modulus "open" Wy1 [cm3] 0.85 0.85 2.54 2.54 4.28 2.42 2.42 7.43
Section modulus Wy2 [cm3] 0.94 0.94 2.66 2.66 4.50 2.42 2.42 7.43
Radius of gyration iy [cm] 0.74 0.74 1.48 1.48 1.80 1.23 1.23 2.50
Permissible moment 2) My [Nm] 121 132 363 396 666 346 377 1158
Z-axis
Moment of inertia Iz [cm4] 4.39 4.39 7.33 7.33 10.79 8.78 8.78 14.67
Section modulus Wz [cm3] 2.13 2.13 3.55 3.55 5.23 4.25 4.25 7.10
Medium duty

Radius of gyration iz [cm] 1.63 1.63 1.73 1.73 1.75 1.63 1.63 1.73
System MQ

Selection of channel section:


HDG

● The given data is based on a single span (simply-supported beam) bearing a single load, F (kN), at mid-span, L/2.
● If several loads are acting on a single span (simply-supported beam), these may be summated and regarded as a single load acting at mid span. By taking this
approach, the design calculation is on the safe side. (➔ Cross section selection table).
● The permissible stress in the steel and the max. deflection, L/200, are not exceeded with the given max. span width, L (cm).
● The channel's own weight was taken into account.
Max. span width, L (cm) / deflection, f (mm) 3)
Stainless Steel
Medium duty

L f L f L f L f L f L f L f L f
System MQ

F (kN) (cm) (mm) (cm) (mm) (cm) (mm) (cm) (mm) (cm) (mm) (cm) (mm) (cm) (mm) (cm) (mm)
0.25 120 6.0 120 6.0 277 13.8 277 13.8 380 19.0 261 13.1 261 13.1 560 28.0
0.50 86 4.3 86 4.3 204 10.2 204 10.2 290 14.5 195 9.7 195 9.7 449 22.5
0.75 64 2.7 70 3.4 168 8.4 168 8.4 242 12.1 161 8.1 161 8.1 383 19.2
1.00 48 1.5 52 1.9 143 6.8 147 7.3 212 10.6 135 6.3 141 7.0 339 16.9
1.25 39 <1 42 1.2 115 4.4 125 5.7 190 9.5 109 4.1 119 5.3 307 15.3
1.50 32 <1 35 <1 96 3.1 105 4.0 174 8.7 91 2.9 99 3.7 282 14.1
System MI

1.75 27 <1 30 <1 83 2.3 90 3.0 150 6.5 78 2.1 85 2.7 257 12.3
HDG

2.00 24 <1 26 <1 72 1.8 79 2.3 132 5.0 69 1.6 75 2.1 226 9.6
2.25 21 <1 23 <1 64 1.4 70 1.8 118 4.0 61 1.3 67 1.7 202 7.7
2.50 19 <1 21 <1 58 1.1 63 1.5 106 3.3 55 1.1 60 1.4 182 6.3
2.75 17 <1 19 <1 53 <1 57 1.2 96 2.7 50 <1 55 1.1 166 5.3
3.00 16 <1 17 <1 48 <1 53 1.0 88 2.3 46 <1 50 <1 153 4.4
Fixed points
System MQ
and sliders

3.50 14 <1 15 <1 41 <1 45 <1 76 1.7 39 <1 43 <1 131 3.3
4.00 12 <1 13 <1 36 <1 39 <1 66 1.3 34 <1 38 <1 115 2.5
4.50 10 <1 11 <1 32 <1 35 <1 59 1.0 31 <1 33 <1 102 2.0
5.00 9 <1 10 <1 29 <1 32 <1 53 <1 27 <1 30 <1 92 1.6
6.00 8 <1 8 <1 24 <1 26 <1 44 <1 23 <1 25 <1 77 1.1
7.00 6 <1 7 <1 21 <1 22 <1 38 <1 19 <1 21 <1 66 <1
Airconditioning
and Ventilation

System MQ

8.00 5 <1 6 <1 18 <1 20 <1 33 <1 17 <1 19 <1 58 <1


Single load
Selection example: F[kN]
● 1.0 kN (≈100 kg) should be carried by a channel with a channel span Conversion kp kg N kN
width L = 100 cm (single span simply supported). 1 kp – 1 10 0.01
Solution: 1 kg 1 – 10 0.01 L/2 L/2
● Select the line showing the load, F = 1.0 kN. 1N 0.1 0.1 – 0.001 L[cm]
● The MQ-41-RA2 to MQ-41D-R channels can be used because the
Firestop systems

permissible span width (tabluated value) is larger or equal 1 kN 100 100 1000 – F

to the required span, L = 100 cm.


1)
The smaller value (Wy1, Wy2) is decisive for the calculated bending dimension (Wy1 = Iy/e1 or Wy2 = Iy/e2). f[mm]
2)
Perm. My = σperm.· min. (Wy1, Wy2)
3)
The channel length is max. 6.0 m. Contact Hilti technical staff about channels longer than 6.0 m!

page 126
page 34
System MQ channelSystem MQ stainless
installation Stainless steel
Steel
System MQ channel installation stainless steel

Load, F (kN)
Channel
Channel selection
selection diagram
diagram
Load,
25.00 F (kN)
25.00

and Technical
(stainless steel)

PC Software

Information
(stainless steel)
Single
Single span
span 20.00
(simply
(simply supported)
supported)
20.00

with single load at mid span, L/2


with single load at mid span, L/2
All values were calculated for a permissible stress of 15.00
All values were calculated for a permissible stress of 15.00
σperm. (see technical data for channel selection) and a
σperm. (see technical data for channel selection) and a

Medium duty
deflection of L/200.

System MM
deflection of L/200.

Light duty
MQ-52-R
MQ-52-R
10.00
F[kN]
F[kN]
10.00

MQ-41-R
®
®
MQ-41-R
Stainless
Stainless 5.00
steel 5.00
L/2
L/2 L/2
L/2
steel MQ-41-RA2
MQ-41-RA2
MQ21-R
MQ21-R

Medium duty
System MQ
L[cm]
L[cm] MQ-21-RA2
MQ-21-RA2
0.00
0.00 0 25 50 100 150 200 250 300
0 25 50 100 150 200 250 300
Span
Span width
width (cm)
(cm)
Load,FF(kN)
Load, (kN)
30.00
30.00

Hilti Pipe Rings


25.00
25.00

20.00
20.00
MQ-41D-R
MQ-41D-R

Medium duty
System MQ
15.00
15.00

HDG
10.00
10.00

Stainless Steel
MQ-21D-R
MQ-21D-R

Medium duty
System MQ
5.00
5.00

MQ-21D-RA2
MQ-21D-RA2
0.00
0.00
00 25
25 100
100 200
200 300
300 400
400 500
500 600
600
Span width
Span (cm)
width (cm)

Channel selection
selection table (stainless
(stainless steel)

System MI
Channel steel)

HDG
Singlespan
Single span(simply
(simplysupported)
supported)
withsingle
with singleload
loadat
atmid
midspan,
span, L/2
L/2

F[kN] 2 2
2.5

F[kN]
2.5
22

82.6
82.6

2
2
52

Fixed points
41.2
22

41.3

System MQ

and sliders

L/2 L/2
52

41.2
41.3

L/2 L/2
20.6
20.6

L[cm]
L[cm] 41.3 41.3
41.3
41.3
41.3
41.3
41.3
41.3
41.3
41.3

Max. load,
Max. load, FF (kN)
(kN) // deflection,
deflection, ff (mm)
(mm)
MQ-21-RA2 MQ-21-R MQ-41-RA2 MQ-41-R MQ-52-R MQ-21D-RA2 MQ-21D-R MQ-41D-R
MQ-21-RA2 MQ-21-R MQ-41-RA2 MQ-41-R MQ-52-R MQ-21D-RA2 MQ-21D-R MQ-41D-R
Span width F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm)
Span width F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm) F (kN) f (mm)
L (cm) max. L/200 max. L/200 max. L/200 max. L/200 max. L/200 max. L/200 max. L/200 max. L/200
L (cm) max. L/200 max. L/200 max. L/200 max. L/200 max. L/200 max. L/200 max. L/200 max. L/200
25 1.92 <1 2.10 <1 5.77 <1 6.29 <1 10.59 <1 5.48 <1 5.98 <1<1 18.36
18.36 <1<1
Airconditioning
and Ventilation

25 1.92 <1 2.10 <1 5.77 <1 6.29 <1 10.59 <1 5.48 <1 5.98
System MQ

50
50 0.96
0.96 1.6
1.6 1.05
1.05 1.8
1.8 2.90
2.90 <1
<1 3.16
3.16 <1
<1 5.32
5.32 <1
<1 2.75
2.75 <1
<1 3.00
3.00 <1<1 9.23
9.23 <1<1
75
75 0.64
0.64 3.6
3.6 0.66
0.66 3.8
3.8 1.93
1.93 1.9
1.9 2.10
2.10 2.0
2.0 3.54
3.54 1.6
1.6 1.83
1.83 1.9
1.9 2.00
2.00 2.1
2.1 6.15
6.15 1.0
1.0
100 0.37 5.0 0.37 5.0 1.44 3.3 1.57 3.6 2.65 2.9 1.37 3.4 1.49 3.7 4.61 1.9
100 0.37 5.0 0.37 5.0 1.44 3.3 1.57 3.6 2.65 2.9 1.37 3.4 1.49 3.7 4.61 1.9
125 0.23 6.3 0.23 6.3 1.15 5.2 1.25 5.7 2.11 4.5 1.09 5.3 1.19 5.8 3.68 2.9
125 0.23 6.3 0.23 6.3 1.15 5.2 1.25 5.7 2.11 4.5 1.09 5.3 1.19 5.8 3.68 2.9
150 0.15 7.5 0.15 7.5 0.95 7.5 0.95 7.5 1.75 6.5 0.88 7.5 0.88 7.5 3.06 4.2
150 0.15 7.5 0.15 7.5 0.95 7.5 0.95 7.5 1.75 6.5 0.88 7.5 0.88 7.5 3.06 4.2
175 0.11 8.8 0.11 8.8 0.69 8.8 0.69 8.8 1.49 8.8 0.63 8.8 0.63 8.8 2.61 5.7
Firestop systems

175 0.11 8.8 0.11 8.8 0.69 8.8 0.69 8.8 1.49 8.8 0.63 8.8 0.63 8.8 2.61 5.7
200 0.08 10.0 0.08 10.0 0.52 10.0 0.52 10.0 1.13 10.0 0.47 10.0 0.47 10.0 2.27 7.4
200 0.08 10.0 0.08 10.0 0.52 10.0 0.52 10.0 1.13 10.0 0.47 10.0 0.47 10.0 2.27 7.4
225 0.05 11.3 0.05 11.3 0.40 11.3 0.40 11.3 0.88 11.3 0.36 11.3 0.36 11.3 2.01 9.4
225 0.05 11.3 0.05 11.3 0.40 11.3 0.40 11.3 0.88 11.3 0.36 11.3 0.36 11.3 2.01 9.4
275 0.02 13.8 0.02 13.8 0.25 13.8 0.25 13.8 0.56 13.8 0.22 13.8 0.22 13.8 1.58 13.8
275 0.02 13.8 0.02 13.8 0.25 13.8 0.25 13.8 0.56 13.8 0.22 13.8 0.22 13.8 1.58 13.8
300 0.01 15.0 0.01 15.0 0.20 15.0 0.20 15.0 0.46 15.0 0.17 15.0 0.17 15.0 1.31 15.0
300 0.01 15.0 0.01 15.0 0.20 15.0 0.20 15.0 0.46 15.0 0.17 15.0 0.17 15.0 1.31 15.0

page
page127
page 35
35
System MQ channel installation stainless steel
System MQ Stainless Steel

Technical data for brackets (stainless steel A5)


and Technical
PC Software
Information

Type of load 1: uniform Type of load 2: single Type of load 3 Type of load 4 Type of load 5
F1 F1 F2 F2 F3 F3 F3
F1 = q · i 1/
2
1/2 1/3 1/3 1/3 1/4 1/4 1/4 1/4

F1 [N] F1 [N] F1 [N] F2 [N] F3 [N]


Channel
Bracket L (mm) HVZ-R M121) HST-R M122) HVZ-R M121) HST-R M122) HVZ-R M121) HST-R M122) HVZ-R M121) HST-R M122) HVZ-R M121) HST-R M122)
MQK-21/300-R 300 870 870 870 870 340 340 430 430 290 290
Medium duty

System MM
Light duty

MQK-21/450-R 450 400 400 570 570 150 150 250 250 150 150
MQK-41/300-R 300 2620 2620 2620 2620 1310 1310 1310 1310 870 870
MQK-41/450-R 450 1740 1740 1740 1740 870 870 870 870 580 580
MQK-41/600-R 600 1300 1300 1300 1300 500 500 650 650 430 430
MQK-21 D/450-R 450 1650 1650 1650 1650 830 830 820 820 550 550
MQK-41 D/750-R 750 3050 1890 3050 1890 1520 940 1520 940 1010 630
Loading capacity of the bracket (steel loading capacity) or with HVZ-R M12 fastening, the loading capacity of the bracket is reached with the HVZ-R M12.
Medium duty

1)
System MQ

Loading capacity of the bracket with HST-R fastening, alternatively, loading values with HIT-RTZ M12 are at least those with HST-R M12.
2)

Load values are for grade C20/25 concrete (≈ B25).


Alternatively, fastening in solid or hollow brick with HIT HY 50 and approval is possible. Use stainless-steel anchor rods (loading values not given in this table).
The bracket’s own weight has been allowed for.
The loads apply only if the bracket is fastened away from a building component edge (fastenings made at component edges must be designed separately).
Separate verification must be provided that forces are transferred to the respective base material, i.e. steel and concrete.
Hilti Pipe Rings

The application guidelines in anchor approvals must be observed. Loading values according to approval status July 2005.
The deflection (deformation) of L/150 was observed in all cases, this being measured at the point of load application.

HVZ-R adhesive anchor HST-R stud anchor


EDELSTAHL ®
® ®
EDELSTAHL ®

Rost
Stainless Rost
Stainless
frei
steel frei
steel
Medium duty
System MQ
HDG

Technical data for brackets with angle brace (stainless steel A5)
Type of load 1: uniform Type of load 2: single Type of load 3 Type of load 4 Type of load 5
Stainless Steel
Medium duty

F1 F1 F2 F2 F3 F3 F3
System MQ

F1 = q · I 1/2 1/2 1/3 1/3 1/3 1/4 1/4 1/4 1/4

Bracket L (mm) Brace F1 [N] 1) F1 [N] 1) F1 [N] 1) F2 [N] 1) F3 [N] 1)


MQK-21/450-R 450 short 4520 1170 420 2020 1780
MQK-41/450-R 450 short 5360 3520 2440 2680 1780
MQK-41/600-R 600 long 4060 2630 2030 2030 1350
System MI

MQK-21 D/450-R 450 short 5360 3350 2320 2680 1780


HDG

MQK-41 D/750-R 750 long 3220 3220 1610 1610 1070


1)
Loading capacity of the bracket (steel loading capacity) or the loading capacity of the bracket is reached with the HVZ-R, HIT-RTZ or HST-R M12 fastening.
Load values are for grade C20/25 concrete (≈ B25).
Alternatively, fastening in solid or hollow brick with HIT HY 50 and approval is possible. Use stainless-steel anchor rods (loading values not given in this table).
The bracket’s own weight has been allowed for.
The loads apply only if the bracket is fastened away from a building component edge (fastenings made at component edges must be designed separately).
Fixed points
System MQ
and sliders

Separate verification must be provided that forces are transferred to the respective base material, i.e. steel and concrete.
The application guidelines in anchor approvals must be observed. Loading values according to approval status July 2005.
The deflection (deformation) of L/150 was observed in all cases, this being measured at the point of load application.
Airconditioning
and Ventilation

System MQ
Firestop systems

page 128
page 36
page 129
System MQ Stainless Steel

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
System MQ Stainless Steel

page 130
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
System MQ channelSystem MQ stainless
installation Stainlesssteel
Steel

Channel nut

and Technical
PC Software

Information
Features:
■ Simple, compact, time saving.
■ Single part which can be prefitted.
■ Easy to use.
■ Universal: one and the same nut for all channels.

Medium duty
System MM
Light duty
Technical data:

Medium duty
Material: Stainless steel

System MQ
®

Pushbutton Stainless
steel

Bolt: M10 material A4-70 as per DIN EN ISO 3506-1

Hilti Pipe Rings


Width across flats: 17 mm
Nut: 1.4581 as per DIN EN 10 283
Plate: 1.4401 (A4) as per DIN 17 440
Connection Weight Packaging Outside packaging Ordering Item no.
thread each (g) contents (pcs) contents (pcs) designation
M10 77 25 200 MQN-R 304012

Medium duty
System MQ
Rec. tensile load, Rec. shear load, Tightening torque
Zrec (kN) Qrec (kN) MD (Nm)

HDG
Item Channel I Channel II IBMB no. 3897/1802-5

MQN-R 5.0 8.0 5.0 1) 40


Channel I: MQ-21, MQ-41, MQ-21D, MQ-41D (stainless steel)
Channel II: MQ-52 (stainless steel)
1)
Shear loading applies to single fastening. Qrec (kN) 9.0 for two fastenings

Stainless Steel
Medium duty
System MQ
System MI
HDG
®

Wing nut Stainless


steel
M 6
M 8
M10
M12
Fixed points
System MQ

and sliders

Nut, M6–M12: 1.4581 as per DIN EN 10 283


Plastic: PA
Connection Weight Packaging Outside packaging Ordering Item no.
thread each (g) contents (pcs) contents (pcs) designation
M 6 29 25 500 MQM-M6-R 304014
M 8 27 25 500 MQM-M8-R 304015
Airconditioning
and Ventilation

M10 25 25 500 MQM-M10-R 304016


System MQ

M12 23 25 500 MQM-M12-R 304017

Rec. tensile load, Rec. shear load, Tightening torque


Zrec (kN) Qrec (kN) MD (Nm)
Item Channel I Channel II (bolt A4-70)
MQM-M 6-R 3.0 3.0 1.5 10
MQM-M 8-R 5.0 5.0 3.5 20
Firestop systems

MQM-M10-R 5.0 8.0 5.0 40


MQM-M12-R 5.0 8.0 5.0 40
Channel I: MQ-21, MQ-41, MQ-21D, MQ-41D (stainless steel)
Channel II: MQ-52 (stainless steel)

page
page131
39
System
System MQ
System MQ Stainless
MQ channel Steel
channel installation
installation stainless
stainless steel
steel

Pipe ring saddle


and Technical
PC Software
Information

Features:
■ Single part, simple and time-saving in use.
■ For all types of channels.
■ For threaded rods from M8 to M16.
Medium duty

System MM
Light duty

Technical data:
Medium duty

Material: Stainless steel


System MQ

MQA-R pipe ring saddle


®
®

Stainless
Stainless
steel
steel
M
M 88
Nut: 1.4581 as per DIN EN 10 283 M10
M10
Plate: 1.4401 (A4) as per DIN 17 440 M12
M12
Hilti Pipe Rings

M16
M16
Plastic: PB
Connection
Connection Weight
Weight Packaging
Packaging Outside
Outside packaging
packaging Ordering
Ordering Item
Itemno.
no.
thread
thread each
each (g)
(g) contents
contents (pcs)
(pcs) contents
contents (pcs)
(pcs) designation
designation
M8 75 25 200 ➀
➀ MQA-M
MQA-M 8-R
8-R 304021
304021
M10 73 25 200 ➁
➁ MQA-M10-R
MQA-M10-R 304022
304022
M12 71 25 200 ➁
➁ MQA-M12-R
MQA-M12-R 304023
304023
M16 84 25 200 ➁
➁ MQA-M16-R
MQA-M16-R 304024
304024
Medium duty
System MQ

Rec.
Rec. tensile
tensile load,
load, Tightening
Tightening torque
torque Bending
Bending moment,
moment,threaded
threaded
ZZrecrec (kN)
(kN) M
MDD (Nm)
(Nm) rod
rod A4-70
A4-70 (Nm)
(Nm) 1)1)
HDG

Item
Item Channel
Channel II Channel
Channel IIII
MQA-M 8-R 3.0 3.0 9 12.1
12.1
MQA-M10-R 5.0 7.0 18 24.1
24.1
MQA-M12-R 5.0 8.0 31 42.1
42.1
MQA-M16-R 5.0 8.0 40 100.0
100.0
Stainless Steel

Channel I: MQ-21, MQ-41, MQ-21D, MQ-41D (stainless


(stainless steel)
steel)
Medium duty
System MQ

Channel II: MQ-52 (stainless steel)


1)
1)
Calculation
Calculation as
as per
per DIBt
DIBt

Pipe ring saddles ➁ firestop tested


System MI

IBMB
IBMB no.
no. 3897/1802-5
3897/1802-5
HDG

MQG-2-R base plate


®
M16
M16 50
50
Stainless
Stainless 1/2" 155
1/2" 155
steel
steel 3/4"
3/4"
Material: 1.4571 (A5) 1"
1"

Connection
Connection Weight
Weight Packaging
Packaging Ordering
Ordering Item
Itemno.
no.
thread
thread each
each (g)
(g) contents
contents (pcs)
(pcs) designation
designation
Fixed points
System MQ

100
and sliders

100
M16 180 20 MQG-2-M16-R
MQG-2-M16-R 304028
304028
/22″
11
170 20 MQG-2-11//22″-R
MQG-2- ″-R 304029
304029
/44″
33
185 20 MQG-2-33//44″-R
MQG-2- ″-R 304030
304030
1″ 205 20 MQG-2-1″-R
MQG-2-1″-R 304031
304031
Rec.
Rec. tensile
tensile load,
load, Rec.
Rec. shearshear load,
load, Tightening
Tightening torque
torque Bending
Bendingmoment,
moment,
Item
Item ZZrecrec (kN)
(kN) QQrecrec (kN)
(kN) M
MDD (Nm)
(Nm) threaded
threadedrod
rodA4-70
A4-70 (Nm)
(Nm)
Airconditioning
and Ventilation

MQG-2-M16-R 6.0 9.0 40 100.0


100.0
System MQ

MQG-2-11/22″-R 6.0 9.0 40 42.1


42.1
MQG-2-33/44″-R 6.0 9.0 40 200.0
200.0
MQG-2-1″-R 6.0 9.0 40 200.0
200.0
Firestop systems

page 132
page
page 40
40
■ The MQN-R pushbutton can be prefitted.

System MQ channelSystem MQ stainless


installation Stainlesssteel
Steel

Technical data:
Material: Stainless steel, 1.4571(A5)
Angles,
Material angle
thickness: brackets,
4 mm

and Technical
connectors

PC Software

Information
90º angle Stainless�
®�

Features: 19
Frec 3.0 kN Frec 2.4 kN
steel 19.4
■ Univesal: few parts for all applications.
■ Easy to use. Weight Packaging Ordering Item no.
61 61
each (g) contents (pcs) designation
■ Three-dimensional, thus high strength. 35 10
Angle, 2 hole, 90°
■ The MQN-R pushbutton can be prefitted.
110 10 ➀ MQW-2-R 304051
Angle, 4 hole, 90° 220 10 ➁ MQW-4-R 304054

Medium duty
System MM
Angle, 8 hole, 90° 420 10 ➂ MQW-8/90°-R 304055

Light duty
Angle, 3 hole, 90° 160 10 ➃ MQW-3-R 304052
➁ Frec 5.0 kN Frec 3.7 kN
➂ Frec 9.0 kN Frec 5.0 kN

Frec 6.8 kN Frec 2.5 kN

Technical data: 61

Material: Stainless steel, 1.4571(A5) 111

Medium duty
Material thickness: 4 mm

System MQ
55 105

90º angle
®�

Stainless � Frec 3.0 kN Frec 2.4 kN
steel
Frec 9.0 kN Frec 5.0 kN
45º angle
®�

Stainless � Weight Packaging Ordering Item no. ➀ 105


61
61
steel each (g) contents (pcs) designation 45°

Hilti Pipe Rings


Angle, 2 hole, 90° 110 10 ➀ MQW-2-R 304051
Weight Packaging Ordering Item no.
Angle, 4 hole, 90° 220
each (g)
10
contents (pcs)
➁ MQW-4-R
designation
304054
Angle,
Angle, 88 hole,
hole, 90°
45° 420
410 10
10 ➂
➀ MQW-8/90°-R
MQW-8/45°-R 304055
304056
Angle,
Angle, 3 hole, 90°
3 hole, 45° 160
155 10
10 ➃
➁ MQW-3-R
MQW-3/45°-R 304052
304053
➁ Frec 5.0 kN Frec 3.7 kN
➂ Frec 9.0 kN Frec 5.0 kN

➁ 106 Frec 7.0 kN Frec 2.5 kN
Frec 6.8 kN Frec 2.5 kN
45°

56
61

Medium duty
System MQ
111

HDG
55 105

®�

� ➀ ➁
Angle bracket Stainless
steel
110 198

Frec 9.0 kN Frec 5.0 kN


45º angle
®�
Weight Packaging Ordering Item no.
Stainless � each (g) contents (pcs) designation ➀ 105

Stainless Steel
Frec 2.0 kN Frec 3.0 kN

Medium duty
Frec 2.0 kN Frec 3.0 kN
steel
198

System MQ
Angle bracket, one brace 460 10 ➀ MQW-S/1-R 304058
155
45°
118
100

Angle bracket, two braces 1180


Weight
10
Packaging
➁ MQW-S/2-R
Ordering
304059
Item no. Frec 8.0 kN Frec 5.0 kN 13.5 Frec 9.0 kN Frec 6.0 kN
each (g) contents (pcs) designation 13.5

Angle, 8 hole, 45° 410 10 ➀ MQW-8/45°-R 304056


Angle, 3 hole, 45° 155 10 ➁ MQW-3/45°-R 304053
➁ 106 Frec 2.0 kN Frec 3.0 kN Frec Frec
7.0 kN Frec 4.0 kN
2.56.0kN
Frec kN
45°

System MI
56

HDG
®� ®� 167

� � ➀ ➁
Angle bracket
Connector, two dimensional Stainless
steel
Stainless
steel
110
Frec
198

9.0 kN
112 Frec 7.0 kN
Fixed points

Weight
Weight Packaging
Packaging Ordering
Ordering Item no.
System MQ

and sliders

each
each(g)
(g) contents (pcs)
contents (pcs) designation
designation
Frec
Frec
2.0 kN
2.0 kN
Frec
Frec
3.0 kN
3.0 kN
198

Angle bracket, onetwo


brace 460 1010 ➀ MQW-S/1-R 304058
155
Connector, triple, dimensional 602 MQV-3/2D-R 304034 118
100

Angle bracket, two braces 1180 10 ➁ MQW-S/2-R 304059


Frec 8.0 kN Frec 5.0 kN 13.5 Frec 9.0 kN Frec 6.0 kN
13.5

page 41
Airconditioning
and Ventilation
System MQ

Frec 2.0 kN Frec 3.0 kN Frec 4.0 kN Frec 6.0 kN

®� 167


Connector, two dimensional Stainless
Firestop systems

steel
Frec 9.0 kN
112 Frec 7.0 kN
Weight Packaging Ordering Item no.
each (g) contents (pcs) designation
Connector, triple, two dimensional 602 10 MQV-3/2D-R 304034

page
page133
41
System
SystemMQ
MQStainless Steel
channel installation stainless steel

® 55

Connector, three dimensional Stainless


steel
and Technical
PC Software
Information

Weight Packaging Ordering Item no.


each (g) contents (pcs) designation 112

Connector, triple, three dimensional 451 10 MQV-3/3D-R 304035

Connector, two dimensional


167
Stainless Frec 9.0 kN
Medium duty

System MM

steel
Light duty

Frec 5.0 kN

Weight Packaging Ordering Item no.


each (g) contents (pcs) designation 112

Connector, double, two dimensional 440 10 MQV-2/2D-R 304032


Medium duty
System MQ

Longitudinal channel connector Stainless


steel 205

45

Weight Packaging Ordering Item no.


each (g) contents (pcs) designation
Channel connector, 12 hole 555 10 MQV-12-R 304037
Hilti Pipe Rings

Channel base / Base material


connector
Features: 19.4 19
Medium duty

■ Reliable and easy to use.


System MQ

■ Connection of channels to any base material.


HDG

■ The MQN-R pushbutton can be prefitted. 35 10

Technical data:
Stainless Steel
Medium duty

Material: Stainless steel, 1.4571(A5)


System MQ

Separate design verification of the fastening on the base material


must be provided.

Base material connector Stainless


steel
167
System MI

112
Frec 9.0 kN
HDG

Suitable for Weight Packaging Ordering Item no. Frec 5.0 kN


channel height each (g) contents (pcs) designation 112

MQ-41, MQ-21D 440 10 MQV-2/2D-14-R 304033

Frec Channel Bolt Pushbutton Tightening torque


Item (kN) (B) (A) MD (Nm)
Fixed points
System MQ
and sliders

MQV-2/2D-14-R 7.8 MQ-41-R Double MQN-R 40

Stainless
Channel base steel

A
Airconditioning
and Ventilation

105
Suitable for Weight Packaging Ordering Item no.
System MQ

channel height each (g) contents (pcs) designation


20x14

MQ-21 – MQ-72 1150 12 ➀ MQP-21-72-R 304047 6


Frec
MQ-41 D 1880 8 ➁ MQP-82-R 304048 80
135
185

Frec Bolt Pushbutton Tightening torque


Item (kN) (A) MD (Nm) ➁
Firestop systems

MQP-21-72-R 9,0 Double MQN-R 40 A A

MQP-82-R 12,6 Quadruple MQN-R 40 106

20x14
Frec
Channel base  firestop tested 8

150
100 200

IBMB no. 3897/1802-5

page 134
page 42
page 135
System MQ Stainless Steel

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
System MQ Stainless Steel

page 136
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
page 137
System MQ Stainless Steel

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
*Version without acoustic insulation is also available
System MQ Stainless Steel

page 138
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
*Version without acoustic insulation is also available

page 139
System MQ Stainless Steel

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
Adaptor I

Material: 1.4401
Pipe rings
System MQ (A4)steel
stainless
Stainless stainless
Steel steel
Fits MP-MXRI / MP-MRI / MP-MR pipe rings with M16 or M12 boss and MFP-GP-R M16 and LI

MFP-GP-R 3/4″ base plates L

Outside Inside Wrench Length Outside Package Ordering Item no. LA


thread thread size L LA LI dia. contents designation
Stainless steel
[A] [I] [mm]accessories
[SW]
[mm] for pipe rings
[mm] [mm] (pcs)
A
d
and Technical

M12 /4″ 30 39.5 11.5 28 34 25 MGA-R /4″ IG / M12 AG 376256 H


PC Software

3 3
Information

Stainless ∅a
/″
M16 plate
Base 30
3
4 43.5 15.5 28 34 25 MGA-R 3/4″ IG / M16 AG 376257
steel
Material: 1.4571 (A5) stainless steel
Version: Connection boss boss welded all round
109
MGL 2-R
[D] [mm] base
Connection boss
H a
[mm] plate
F [kN] A = 150 mm«light»
Max. load Shear load for
[kN] cont. (pcs)(A5),
Package Ordering Item no.
designation metric two-hole version 150 d 100
9 x 16
Version:
M16 hex.Spot-welded
16 connection
13.5 12.5 boss
2.0 25 MFP-GP-R M16 376258 30
Medium duty

System MM

d3/4″ boss 17 13.5 12.5 2.0 25 MFP-GP-R /4″ 376259


Light duty

3
H a×b FZrec Package Ordering Item no.
[mm] [mm] [mm] [kN] cont. (pcs) designation
3
The means of fastening to the base material, e. g. anchors, requires separate
The means of fastening to the base material, e.g. anchors,requires separate verification verification. H
M8 11 9×16 1.9 10 MGL 2-R-M8 246927 54
80

Adaptor
MGS 2-R base plate «standard» (A5),
I
d
Material: 1.4401version
(A4) stainless steel
Medium duty

11 x 18
metric two-hole
System MQ

40
Fits MP-MXRI / MP-MRI / MP-MR pipe rings with M16 or M12 boss and MFP-GP-R M16 and LI
Version: Spot-welded connection boss
MFP-GP-R 3/4″ base plates 4 L
d H a×b FZrec Package Ordering Item no. H
Outside Inside Wrench Length Outside Package LA
[mm] [mm] [mm] [kN] cont. (pcs) Ordering
designation Item no. 85
thread thread size L LA LI dia. contents designation A
M10
[A] 14
[I] 11×18
[SW] 2.0
[mm] [mm] [mm] [mm] 10
(pcs) MGS 2-R-M10 246931 120

M12 16
3
/4″ 11×18
30 3.0
39.5 11.5 28 34 10
25 MGS 2-R-M12
MGA-R 3
/4″ IG / M12 AG 247762
376256
M16 20
/4″ 11×18
30 3.5
43.5 15.5 28 34 10
25 MGS 2-R-M16
MGA-R /4″ IG / M16 AG 246932
376257
Hilti Pipe Rings

3 3

MGL 2-R base plate «light» (A5), metric two-hole version d


9 x 16
Version: Spot-welded connection boss 30
d H a×b FZrec Package Ordering Item no.
Suitable
[mm] [mm]anchor
[mm] systems:
[kN] cont. (pcs) designation
3
Medium duty
System MQ

H
M8 11 9×16 1.9 10 MGL 2-R-M8 246927 54
HDG

80

HKD-SR HST-R
MGS 2-R base plate «standard» (A5), d
11 x 18
metric two-hole version 40
Stainless Steel

Version: Spot-welded connection boss


Medium duty
System MQ

4
d H a×b FZrec Package Ordering Item no. H
[mm] [mm] [mm] [kN] cont. (pcs) designation 85
Hilti HIT
M10 14 11×18 2.0 HVZ-R
10 / HVA-R
MGS 2-R-M10 246931 120

M12 16 11×18 3.0 10 MGS 2-R-M12 247762


M16 20 11×18 3.5 10 MGS 2-R-M16 246932
System MI
HDG

Suitable anchor systems:


Fixed points
System MQ
and sliders

HKD-SR HST-R
page 54
Airconditioning
and Ventilation

System MQ

Hilti HIT HVZ-R / HVA-R


Firestop systems

page 140

page 54
System MQ Stainless Steel

Threaded rod

and Technical
PC Software

Information
Technical data

Material composition Stainless steel A4-70


Additional product information According DIN 976-1 / Form A

Medium duty
System MM
Light duty
Ordering
Thread diameter Length Order designation Sales Quantity Item Number

M8 1m Threaded rod AM8x1000 A4-70 10 pc 00058666


M10 1m Threaded rod AM10x1000 A4-70 10 pc 00058670
M12 1m Threaded rod AM12x1000 A4-70 5 pc 00058671

Medium duty
System MQ
M16 1m Threaded rod AM16x1000 A4-70 5 pc 00058683
M20 1m Threaded rod AM20x1000 A4-70 5 pc 00058688
M24 1m Threaded rod AM24x1000 A4-70 5 pc 00058689

Hilti Pipe Rings


Medium duty
System MQ

HDG
Stainless Steel
Medium duty
System MQ
Hexagon screw

Technical data

System MI
Material composition Stainless steel A4-70

HDG
Additional product information According DIN 933

Ordering
Thread diameter Thread length Wrench size Order designation Sales Quantity Item Number

M8 20 mm 13 mm Hexagon screw M8x20 A4-70 50 pc 00087640


Fixed points
System MQ

and sliders

M8 25 mm 13 mm Hexagon screw M8x25 A4-70 50 pc 00087637


M10 20 mm 17 mm Hexagon screw M10x20 A4-70 50 pc 00026839
M10 25 mm 17 mm Hexagon screw M10x25 A4-70 50 pc 00087632
M12 20 mm 19 mm Hexagon screw M12x20 A4-70 50 pc 00387988
M12 25 mm 19 mm Hexagon screw M12x25 A4-70 50 pc 00087634
Airconditioning
and Ventilation
System MQ

Firestop systems

page 141
System MQ Stainless Steel

Hexagon nut
and Technical
PC Software
Information

Technical data

Material composition Stainless steel A4-70


Additional product information According DIN 934
Medium duty

System MM
Light duty

Ordering
Thread diameter Wrench size Order designation Sales Quantity Item Number

M8 13 Hexagon nut M8 A4-70 50 pc 00052460


M10 17 Hexagon nut M10 A4-70 50 pc 00052461
M12 19 Hexagon nut M12 A4-70 50 pc 00052462
Medium duty
System MQ

M16 24 Hexagon nut M16 A4-70 25 pc 00052463


M20 30 Hexagon nut M20 A4-70 25 pc 00387992
M24 36 Hexagon nut M24 A4-70 25 pc 00387993
Hilti Pipe Rings

Flat washer

Technical data

Material composition Stainless steel A4 / 140 HV


Medium duty
System MQ
HDG

Ordering
Inside diameter Outside diameter Thickness Additional product information Order designation Sales Quantity Item Number

8.4 mm 16 mm 1.6 mm According DIN 125 / Form A Flat washer A 8,4/16 A4 50 pc 00058622
Stainless Steel

10.5 mm 20 mm 2 mm According DIN 125 / Form A Flat washer A 10,5/20 A4 50 pc 00058042


Medium duty
System MQ

13 mm 24 mm 2.5 mm According DIN 125 / Form A Flat washer A 13/24 A4 50 pc 00058041


17 mm 30 mm 3 mm According DIN 125 / Form A Flat washer A 17/30 A4 25 pc 00387989
21 mm 37 mm 3 mm According DIN 125 / Form A Flat washer A 21/37 A4 25 pc 00387990
25 mm 44 mm 4 mm According DIN 125 / Form A Flat washer A 25/44 A4 25 pc 00387991
System MI
HDG

Threaded coupling round

Technical data
Fixed points
System MQ
and sliders

Material composition Stainless steel A4-70

Ordering
Thread diameter Length Order designation Sales Quantity Item Number
Airconditioning
and Ventilation

System MQ

M8 30 mm Spacer coupling M8x30 A4-70 round 50 pc 00266885


M10 30 mm Spacer coupling M10x30 A4-70 round 25 pc 00266884
M12 40 mm Spacer coupling M12x40 A4-70 round 25 pc 00266880
M16 40 mm Spacer coupling M16x40 A4-70 round 20 pc 00266883
Firestop systems

page 142
Industrial Pipe and
Electrical Supports
Hot Dipped Galvanized
System MI Industrial Pipe and
Electrical Supports
Hot Dipped Galvanized
Hilti. Outperform. Outlast.
System MI - Industrial Pipe and Electrical Support

Description Pages

MI Technical Data 146-147

MI girder 148

Crossbeam connectors 149

Cantilever connectors 150

Pedestal connector 151

Girder extension 152

MI steel connectors: connection to steel beams 153-154

MI concrete connectors: connection to concrete 155-156

MI concrete connectors: connecting to concrete walls 157

MI connectors: multi-angle connectors 158

Pipe clamps: U-bolts for uninsulated pipes 159

Pipe clamps: MI-U-bolts for uninsulated pipes 160

MI pipe clamps: Pipe support for insulated pipes 161

MI accessories 162

Self-locking nut and End caps 163

Beam clamps 164-165

MI / MQ connector 166

MIC-TRC Connector for threaded rod 167

Elevator Connectors 168

page 145
System MI - Industrial Pipe and Electrical Support Hilti MI industrial pipe support system

Technical data /mean values


and Technical

including torsion
PC Software
Information

Technical data
50

50
Medium duty

System MM
Light duty

90 120
25

25
90 s = 3.5 90 s=4

MI-90 MI-120
Material thickness s [mm] 3.5 4.0
Medium duty
System MQ

Cross-sectional area A [mm2] 1002.6 1375.7


Weight of girder [kg /m] 9.43 12.60
Material
Elastic limit (yield strength) f y,k [N/mm2] 235.0 235.0
Permissible tensile stress* σZul [N/mm2] 152.6 152.6
Hilti Pipe Rings

Modulus of elasticity [N/mm2] 210000 210000


Shear modulus [N/mm2] 81000 81000
Surface
Hot-dip galvanized 75 µm ● ●
Cross-section values y-axis
Axis of gravity ey [mm] 45.0 60.0
Medium duty
System MQ

Moment of inertia ly [cm4] 115.34 265.78


HDG

Section modulus Wy [cm3] 25.63 44.30


Radius of gyration iy [cm] 3.39 4.40
Cross-section values x-axis
Axis of gravity ez [mm] 45.00 45.00
Stainless Steel
Medium duty

Moment of inertia lz [cm4] 115.34 173.58


System MQ

Section modulus Wz [cm3] 25.63 38.57


Radius of gyration iz [cm] 3.39 3.55
Torsion data
Torsional moment of inertia Σ lt [cm4] 155.56 297.02
Torsional section modulus Wt = 2* ABredt * [cm3] 45.25 71.63
System MI

* The permissible stress is calculated from σD / γG/Q with γ = 1,4. σD results from higher yield strength due to cold forming in accordance with DAST-RILI016, issued 1992:
HDG

σD = fyk / γM mit γM = 1,1


Fixed points
System MQ
and sliders
Airconditioning
and Ventilation

System MQ
Firestop systems

page 146 page 3


Hilti MI industrial pipe support system System MI - Industrial Pipe and Electrical Support

Single-span subject to bending in one axis

and Technical
F1 when f=L/200, F2 when f=L/300, F when σzul including the framing section’s own weight

PC Software

Information
MI-90, one single load
Einzellast
MI-120, one single load
Einzellast 50
F 50
F

L/2 L/2 90 L/2 L/2 120

Medium duty
L L 25

System MM
25

Light duty
90 s = 3.5
90 s=4

Length of F [kN] f [mm] F1 [kN] f [mm] F2 [kN] f [mm] Length of F [kN] f [mm] F1 [kN] f [mm] F2 [kN] f [mm]
span [mm] ≤ σzul ≤ L/200 ≤ L/300 span [mm] ≤ σzul ≤ L/200 ≤ L/300
250 58.75 < 0.1 – – – – 250 101.32 < 0.1 – – – –
500 30.75 0.3 – – – – 500 53.13 0.2 – – – –
750 20.67 0.8 – – – – 750 35.73 0.6 – – – –
1000 15.54 1.3 – – – – 1000 26.86 1.0 – – – –

Medium duty
System MQ
1250 12.43 2.1 – – – – 1250 21.50 1.6 – – – –
1500 10.34 3.0 – – – – 1500 17.90 2.3 – – – –
1750 8.85 4.1 – – – – 1750 15.32 3.1 – – – –
2000 7.72 5.4 – – – – 2000 13.38 4.0 – – – –
2250 6.85 6.8 – – – – 2250 11.87 5.1 – – – –
2500 6.14 8.4 – – 6.06 8.3 2500 10.66 6.3 – – – –
2750 5.56 10.2 – – 4.97 9.2 2750 9.66 7.7 – – – –

Hilti Pipe Rings


3000 5.08 12.2 – – 4.14 10.0 3000 8.83 9.1 – – – –
3250 4.67 14.3 – – 3.49 10.8 3250 8.12 10.7 – – – –
3500 4.31 16.6 – – 2.97 11.7 3500 7.51 12.4 – – 7.03 11.7
3750 4.00 19.1 3.92 18.8 2.55 12.5 3750 6.98 14.3 – – 6.07 12.5
4000 3.73 21.8 3.41 20.0 2.20 13.3 4000 6.52 16.3 – – 5.28 13.3
4250 3.50 24.6 2.98 21.3 1.91 14.2 4250 6.10 18.4 – – 4.62 14.2
4500 3.30 27.6 2.62 22.5 1.66 15.0 4500 5.74 20.7 – – 4.07 15.0

Medium duty
4750 3.10 30.8 2.31 23.8 1.45 15.8 4750 5.41 23.1 – – 3.60 15.8

System MQ
5000 2.90 34.2 2.05 25.0 1.27 16.7 5000 5.11 25.6 4.98 25.0 3.20 16.7

HDG
5250 2.70 37.8 1.82 26.3 1.11 17.5 5250 4.80 28.2 4.47 26.3 2.85 17.5
5500 2.60 41.6 1.61 27.5 0.97 18.3 5500 4.60 31.0 4.01 27.5 2.54 18.3
5750 2.50 45.5 1.44 28.8 0.85 19.2 5750 4.50 34.0 3.62 28.8 2.27 19.2
6000 2.30 49.7 1.28 30.0 0.74 20.0 6000 4.10 37.1 3.27 30.0 2.03 20.0

Stainless Steel
Medium duty
System MQ
Selection of framing section for single span with max. load when f < L/200 F[kN]

Single central load incl. framing section’s own weight


L

50.00

45.00 MI-90
MI-120

System MI
40.00 MQ-21 D/F*

HDG
MQ-41 D/F*
MQ-41/F*
35.00
MQ-52-72 D/F*
Load F (kN)

30.00
Fixed points
System MQ

and sliders

25.00

20.00

15.00
Airconditioning
and Ventilation
System MQ

10.00

5.00

0.00
Firestop systems

-5.00
0 500 1000 1500 2000 2500 3000
Length of span (mm)

*Technical data for the MQ System can be found in the Installations Systems main catalogue.

page 4 page 147


System MI - Industrial Pipe and Electrical Support

page 148
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
page 149
System MI - Industrial Pipe and Electrical Support

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
System MI - Industrial Pipe and Electrical Support Hilti MI industrial pipe support system

MI connectors:
and Technical

Cantilever connectors
PC Software
Information

Advantages
■ Fine adjustment in 5 mm increments for maximum flexibility.
■ Only four connecting screws required.
■ Keyed hold for optimum transmission of forces and moments.
■ Self-locking nuts for vibration-resistant screw connections
Medium duty

System MM
Light duty

Technical data
Material: S235 JRG2 as per DIN EN 10 025
Medium duty

Galvanizing: Hot-dip galvanized 55 µm


System MQ

Note
Designed for cantilever applications.
May be supported at only one end.
Hilti Pipe Rings

Cantilever connector with connecting parts


For girder type Weight per Ordering designation Item no. Package 140 8
set [kg] contents
MI-90 3.95 MIC-90-L 304805 2➀
Medium duty
System MQ
HDG

Items in set aus:


Set besteht 315
2x 4x
Stainless Steel
Medium duty
System MQ

75

2x 2x
System MI
HDG

Cantilever connector without connecting parts


Fixed points
System MQ
and sliders

For girder type Weight per Ordering designation Item no. Package
set [kg] contents
MI-90 2.80 MIC-90-L-AP 305710 2
Airconditioning
and Ventilation

System MQ
Firestop systems

page 150 page 13


Hilti MI
Hilti MI industrial
industrial pipe
pipe support
support system
system System MI - Industrial Pipe and Electrical Support

connectors:
MI connectors:

and Technical
connector
Pedestal connector

PC Software

Information
Advantages
Advantages
■ Fine adjustment
■ adjustment in
in 55 mm
mm increments
increments for
formaximum
maximumflexibility.
flexibility.
■ Keyed hold
■ hold for
for optimum
optimum transmission
transmission of
offorces
forcesand
andmoments.
moments.

Medium duty
System MM
Light duty
Technical data
data
Material: S235
S235JRG2
JRG2asasper
perDIN
DINEN
EN 10
10025
025

Medium duty
Galvanizing:
Galvanizing: Hot-dip
Hot-dipgalvanized
galvanized55
55µm
µm

System MQ
Pedestal connector
connector with
with connecting
connecting parts
parts 
 88
120
120

For
For girder
girder type
type Weight
Weightper
per Ordering
Orderingdesignation
designation Item
Itemno.
no. Package
Package
set
set[kg]
[kg] contents
contents

Hilti Pipe Rings


MI-90/MI-120
MI-90/MI-120 2.04
2.04  MIC-T
 MIC-T 304807
304807 22

Items in
in set
set aus:
Set besteht
besteht aus: 220
220
2x
2x

Medium duty
75
75

System MQ

HDG
2x
2x
2x
2x

Stainless Steel
Medium duty
System MQ
System MI
HDG
Fixed points
System MQ

and sliders
Airconditioning
and Ventilation
System MQ

Firestop systems

page 14
page 14 page 151
System MI - Industrial Pipe and Electrical Support

page 152
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Hilti MI industrial pipe support system
Hilti MI industrial pipe support system
Hilti MI industrial pipe support system
System MI - Industrial Pipe and Electrical Support

MI steel connectors:
MI
MI steel
steel connectors:
connectors:
Connection to steel beams B

and Technical
Connection
Connection to
to steel
steel beams

PC Software
BB

Information
beams
Advantages
Advantages
■ For connection to standard steel beams without drilling or welding.
Advantages
■■For connection
Suitable to standard
for connection steel beams
to flange or web.without drilling or welding.
■ For connection to standard steel beams without drilling or welding.
■■Suitable
For use for connection
with MI-GC-M12to flange
beam or web.
clamp.
■ Suitable for connection to flange or web.
■ For use with MI-GC-M12 beam clamp.
■ For use with MI-GC-M12 beam clamp.

Medium duty
System MM
Light duty
Technical data
Technical
Material: data S235 JRG2 as per DIN EN 10 025
Technical data
Material:
Galvanizing: S235 JRG2
Hot-dip as per DIN
galvanized EN 10 025
55 µm
Material: S235 JRG2 as per DIN EN 10 025

Medium duty
Galvanizing: Hot-dip galvanized 55 µm

System MQ
Galvanizing: Hot-dip galvanized 55 µm

Steel connectors with connecting parts


Steel
Steel connectors
For girder type connectors
Steel beam width B
with
with
C
connecting
connecting
D
parts
parts
Weight per Ordering designation Item no. Package
[mm] [mm] [mm] set [kg] contents
For girder type Steel beam width B C D Weight per Ordering designation Item no. Package
ForMI-90
girder type 75–165
Steel beam width B C– D– 4.37
Weight
[kg] per  MIC-S90-AA
Ordering designation 304811
Item no. 2 contents
Package

Hilti Pipe Rings


[mm] [mm] [mm] set
MI-90
MI-90 75–165
[mm]
75–165 –200
[mm] 280
[mm]
– 7.14
set
4.37
[kg] 
 MIC-S90-A
MIC-S90-AA 304812
304811 2 contents
2
MI-90
MI-90
MI-90 75–165
165–235
75–165 –
300
200 –
350
280 4.37
8.59
7.14


 MIC-S90-AA
MIC-S90-B
MIC-S90-A 304811
304813
304812 2 22
MI-90
MI-90
MI-90 75–165
235–300
165–235 200
350
300 280
430
350 7.14
10.24
8.59


 MIC-S90-A
MIC-S90-C
MIC-S90-B 304812
304814
304813 2 22
MI-90
MI-120
MI-90 165–235
75–165
235–300 300
200
350 350
280
430 8.59
7.54
10.24


 MIC-S90-B
MIC-S120-A
MIC-S90-C 304813
304818
304814 2 22
MI-90
MI-120
MI-120 235–300
165–235
75–165 350
300
200 430
350
280 10.24
8.99
7.54


 MIC-S90-C
MIC-S120-B
MIC-S120-A 304814
304819
304818 2 22
MI-120
MI-120
MI-120 75–165
235–300
165–235 200
350
300 280
430
350 7.54
10.65
8.99


 MIC-S120-A
MIC-S120-C
MIC-S120-B 304818
304820
304819 2 22
MI-120
MI-120 165–235
235–300 300
350 350
430 8.99
10.65

 MIC-S120-B
MIC-S120-C 304819
304820 22
MI-120 235–300 350 430 10.65  MIC-S120-C 304820 2

Medium duty
System MQ
12

HDG
140
 60 x 13  D  D
12
140 12 C C
 140 60 x 13  D  D
 60 x 13  BD  B D
C C
C 12 C 12
B B
140 B 140 B

Stainless Steel
12 12

Medium duty
12

System MQ
140 12 140
140 MI-120
B 140
300
MI-120
MI-90 B 150 155 MI-120
150
155
B 300 220
300 MI-90 220
14
14 150 155 150
MI-90 150 155
MI-90 MI-90
60 x 13 150 155 220 60 x 13 155 220
100 220 14 220
MI-90 14 14
1460 x 13 60 x 13
100 60 x 13 60 x 13

System MI
100

HDG
Note:  Note:  + 
Always to be supported at opposite end. Designed for cantilever applications. May be supported at only one end.
Note:  Note:  + 
Note:
Alwaysto be supported at opposite end. Note:  +for
Designed cantilever applications. May be supported at only one end.
Always to be supported at opposite end. Designed for cantilever applications. May be supported at only one end.
Fixed points
System MQ

and sliders

Items in set aus:


Set besteht
2x
Items in set aus:
Set besteht
Items in set aus:
Set besteht
2x
2x

2x
Airconditioning
and Ventilation
System MQ

2x
2x
Firestop systems

page 16

page 16 page 153


page 16
*Availability of other sizes need to be checked with local Hilti organization
*Availability of other sizes need to be checked with local Hilti organization
System MI - Industrial Pipe and Electrical Support

page 154
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Hilti MI industrial pipe support
support system
system System MI - Industrial Pipe and Electrical Support

MI concrete connectors:

and Technical
Connection to concrete

PC Software

Information
Advantages
■ Four elongated holes for easy wall mounting.
mounting.
■ Designed for ceiling, wall and floor mounting.
mounting.

Medium duty
System MM
Light duty
Technical data
Material: S235 JRG2
JRG2 as
as per
per DIN
DIN EN
EN 10
10 025
025

Medium duty
Galvanizing: Hot-dip galvanized
galvanized 55
55 µm
µm

System MQ
Concrete connector with connecting
connecting parts
parts
For
For girder
girder type
type Weight
Weight per
per Ordering
Orderingdesignation
designation Item
Itemno
no Package
Package

Hilti Pipe Rings


set
set [kg]
[kg] contents
contents
MI-90 3.51 
 MIC-C90-AA
MIC-C90-AA 304825
304825 22
MI-90 7.32 
 MIC-C90-D
MIC-C90-D 304827
304827 22
MI-120 7.69 
 MIC-C120-D
MIC-C120-D 304829
304829 22

100

Medium duty
100  

System MQ

  230
230  230
230
156 156

HDG
156 156

12 15
15 15
15
12
140
140
140
140

MI-90
MI-90
140 200
140

Stainless Steel
200

Medium duty
156

System MQ
156
156 156
MI-90
MI-90 230
230
230
230

47 47
47xx17
47xx17
17 17

System MI
Note:
Note: 
 Note:  ++ 
Note:  

HDG
Always
Always to
to be
be supported
supported at
at opposite
opposite end.
end. Designed
Designed for
for cantilever
cantilever applications.
applications.May
Maybe
besupported
supportedat
atonly
onlyone
oneend.
end.

Items
Set in
in set
Set besteht
Items set aus:
besteht aus:
2x
Fixed points

2x
System MQ

and sliders

2x
2x
Airconditioning
and Ventilation
System MQ

Firestop systems

page 18
page 18
page 155
*Availability of other sizes need to be checked with local Hilti organization
System MI - Industrial Pipe and Electrical Support

page 156
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Hilti
Hilti MI
MI industrial
industrial pipe
pipe support
support system
system System MI - Industrial Pipe and Electrical Support

MI concrete
concrete connectors:
connectors:
Connection
Connection to
to concrete
concrete walls

and Technical
walls

PC Software

Information
Advantages
Advantages
■ Lighter
Lighter version
version for
forstructures
structuressupported
supportedatatboth
bothends.
ends.
■ Elongated
■ Elongated holes
holes for
foreasier
easierpositioning.
positioning.
■ Simple
■ Simple support
support for
forinstallation
installationbetween
betweentwo
twowalls.
walls.

Medium duty
System MM
Light duty
Technical
Technical data
data
Material:
Material: S235
S235JRG2
JRG2as asper
perDIN
DINEN
EN10
10025
025
Galvanizing: Hot-dip galvanized 55 µm

Medium duty
Galvanizing: Hot-dip galvanized 55 µm

System MQ
Package:
Package:

Note
Note
Always
Always to
to be
be supported
supportedat
atopposite
oppositeend.
end.
2x
2x

Hilti Pipe Rings


Concrete
Concrete wall
wall connector
connector  200
with 2x 200
with connecting parts
connecting
2x parts 150
150
8
100 8
For girder type Weight per Ordering designation Item no. Package 100
For girder type Weight
set [kg] per Ordering designation Item no. Package
contents
set [kg] contents MI-90
MI-90 2.29  MIC-C90-U 304826 2 MI-90

Medium duty
MI-90 2.29  MIC-C90-U 304826 2

System MQ
100

HDG
100
25 x 14
25 x 14
Items in set aus:
Set besteht
Items in set aus:
Set besteht
1x
1x

Stainless Steel
Medium duty
System MQ
1x
1x

System MI
HDG
Fixed points
System MQ

and sliders
Airconditioning
and Ventilation
System MQ

Firestop systems

page 20
page 20 page 157
System MI - Industrial Pipe and Electrical Support

page 158
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
page 159
System MI - Industrial Pipe and Electrical Support

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
431587
431588
431589
431590
431591
431592
431593
431594
431595
431598

* Please check the availability with local Hilti organization


System MI - Industrial Pipe and Electrical Support

page 160
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Hilti
Hilti MI
MI industrial
industrial pipe
pipe support
support system
system System MI - Industrial Pipe and Electrical Support

MI pipe
pipe clamps:
clamps: 
 FyF
– Fz
– Fz  – Fz– Fz
 – Fz– Fz

and Technical
Pipe supports
supports for
for insulated
insulated pipes
y
pipes

PC Software
L1 L L1 L

Information
1 1
s s Fy F Fy F
y y
Da D Da D
DaD s s a a
a s s

Advantages
Advantages B B
B B B B

■ With mounting
mounting holes
holesfor
forinstalling
installinglight-duty
light-dutyfixed
fixedpoints.
points.
H H
■ FxF H H H
Fx F H
x x Fx F
F F F F x F F

1313 13 13 L 13 13 L
L L W W L
WW W L
W + Fz
+ Fz
+ F+z F + Fz
z

Medium duty
+ Fz

System MM
Light duty
11ring
ring/ 1/ 1rib
rib 2 2rings
rings/ 1/ 1ribrib Heavy-duty
Heavy-dutyversion
version
for
forDN25-DN150
DN25-DN150 forforDN25-DN300
DN25-DN300 forfor
DN200-DN600
DN200-DN600

7575

55

Medium duty
System MQ
8
8
Technical
Technical data
data for
for the
theclamping
clampingsystem
system
Material:
Material: S235
S235JRG2
JRG2asasper
perDIN
DINEN
EN10025
10025
Galvanizing:
Galvanizing: Hot-dip galvanized 70 µm
Hot-dip galvanized 70 µm
Temperatures: Up
Upto
to300
300°C Low-friction
Temperatures: °C Low-frictionplate
plate Sliding
Slidingsupport
supportclamps
clamps Fixed point
Fixed point

Hilti Pipe Rings


*Availability of other sizes need to be checked with local Hilti organization
Nominal Pipe outside B s F W H L L1 Clamping Weight per Permissible loads Ordering designation Item no. Package
Nominal
size Pipe outside
diameter Da B s F W H L L1 Clamping
screw Weight per Fx
set Permissible
+ Fz loads
– Fz Fy Ordering designation Item no. contents
Package
size
NW diameter Da
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] screw set
[kg] Fx
(kN) + Fz
(kN) – Fz
(kN) Fy
(kN) contents
NW [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [kg] (kN) (kN) (kN) (kN)
25
25 33.7
33.7 30
30 66 99 80
80 85
85 250
250 –– M10
M10 2.8
2.8 0.4
0.4 0.8
0.8 0.3
0.3 0.3
0.3
MI-PS1/1 25-85
MI-PS1/1 25-85 304844
304844 22
25 33.7 30 6 8 82 140 250 – M10 2.4 0.4 0.8 0.3 0.3  MI-PS1/1 25-140 286957 2
25 33.7 30 6 8 82 140 250 – M10 2.4 0.4 0.8 0.3 0.3  MI-PS1/1 25-140 286957 2
40 48.3 30 6 9 80 85 250 – M10 2.8 0.5 1.0 0.3 0.3  MI-PS1/1
 MI-PS1/140-85 304845 2
40 48.3 30 6 9 80 85 250 – M10 2.8 0.5 1.0 0.3 0.3 40-85 304845 2
40 48.3 30 6 8 82 140 250 – M10 2.4 0.5 1.0 0.3 0.3  MI-PS1/1
 MI-PS1/140-140 286958 2
40 48.3 30 6 8 82 140 250 – M10 2.4 0.5 1.0 0.3 0.3 40-140 286958 2

Medium duty
System MQ
50 60.3 40 6 9 80 85 250 – M12 3.2 0.9 1.8 0.6 0.6  MI-PS1/1 50-85 304846 2
50 60.3 40 6 9 80 85 250 – M12 3.2 0.9 1.8 0.6 0.6  MI-PS1/1 50-85 304846 2
50 60.3 40 6 8 82 140 250 – M12 2.7 0.9 1.8 0.6 0.6  MI-PS1/1
 MI-PS1/150-140 286959 2

HDG
50 60.3 40 6 8 82 140 250 – M12 2.7 0.9 1.8 0.6 0.6 50-140 286959 2
65 76.1 40 6 9 80 85 250 – M12 3.3 1.1 2.1 0.7 0.7  MI-PS1/1 65-85 304847 2
65
65
76.1
76.1
40
40 6
6 8
9 80
82 140
85 250
250 –
– M12
M12
3.3
2.8
1.1
1.1
2.1
2.1
0.7
0.7
0.7
0.7
 MI-PS1/1 65-85
 MI-PS1/1 65-140
304847
286960 2
2
65
80 76.1
88.9 40
40 66 98 82
80 140
85 250
250 –– M12
M12 2.8
3.3 1.1
1.2 2.1
2.3 0.7
0.8 0.7
0.8 MI-PS1/180-85
MI-PS1/1 65-140 286960
304848 22
80
80 88.9
88.9 40
40 66 89 80
82 14085 250
250 –– M12
M12 3.3
2.9 1.2
1.2 2.3
2.3 0.8
0.8 0.8
0.8
 MI-PS1/1 80-85
 MI-PS1/1 80-140 304848
286961 22
80
100 88.9
114.3 40
40 86 98 82
80 140
85 250
250 –– M12
M12 2.9
3.8 1.2
2.5 2.3
5.0 0.8
1.7 0.8
1.7 MI-PS1/1100-85
MI-PS1/1 80-140 286961
304849 22
100 114.3 40 88 89 80 85 250 –– M12 3.8 2.5 5.0 1.7 1.7 MI-PS1/1100-140
MI-PS1/1 100-85 304849 22

Stainless Steel
100 114.3 40 80 140 250 M12 3.4 2.5 5.0 1.7 1.7 286962

Medium duty
System MQ
100
125 114.3
139.7 40
40 88 98 80
80 140
85 250
250 –– M12
M12 3.4
4.0 2.5
2.9 5.0
5.8 1.7
1.9 1.7
1.9 MI-PS1/1125-85
MI-PS1/1 100-140 286962
304850 22
125
125 139.7
139.7 40
40 88 89 80
80 14085 250
250 –– M12
M12 4.0
3.6 2.9
2.9 5.8
5.8 1.9
1.9 1.9
1.9 MI-PS1/1125-140
MI-PS1/1 125-85 304850
286963 22
125
150 139.7
168.3 40
40 88 98 80
80 140
85 250
250 –– M12
M12 3.6
4.2 2.9
3.2 5.8
6.4 1.9
2.1 1.9
2.1 MI-PS1/1150-85
MI-PS1/1 125-140 286963
304851 22
150
150 168.3
168.3 40
40 88 89 80
80 14085 250
250 –– M12
M12 4.2
3.8 3.2
3.2 6.4
6.4 2.1
2.1 2.1
2.1 MI-PS1/1150-140
MI-PS1/1 150-85 304851
286964 22
150 168.3 40 8 8 80 140 250 – M12 3.8 3.2 6.4 2.1 2.1  MI-PS1/1 150-140 286964 2
25 21.3 30 5 9 80 85 250 200 M10 3.3 0.8 1.5 0.5 0.5  MI-PS2/1 25-85 304852 2
25
25 21.3
21.3 30
30 55 99 80
80 14085 250
250 200
180 M10
M10 3.3
3.7 0.8
0.8 1.5
1.5 0.5
0.5 0.5
0.5 MI-PS2/125-140
MI-PS2/1 25-85 304852
286965 22
25
40 21.3
48.3 30
30 55 99 80
80 140
85 250
250 180
200 M10
M10 3.7
3.4 0.8
1.0 1.5
2.0 0.5
0.7 0.5
0.7 MI-PS2/140-85
MI-PS2/1 25-140 286965
304853 22

System MI
40
40 48.3
48.3 30
30 55 99 80
80 14085 250
250 200
180 M10
M10 3.4
3.8 1.0
1.0 2.0
2.0 0.7
0.7 0.7
0.7 MI-PS2/140-140
MI-PS2/1 40-85 304853
286966 22
40 48.3 30 65 99 80 140 250 180 M10 3.8 1.0 2.0 0.7 0.7 MI-PS2/150-85
40-140 286966 22

HDG
50 60.3 40 80 85 250 190 M12 4.1 1.8 3.5 1.2 1.2 MI-PS2/1 304854
50
50 60.3
60.3 40
40 66 99 80
80 14085 250
250 190
180 M12
M12 4.1
4.5 1.8
1.8 3.5
3.5 1.2
1.2 1.2
1.2 MI-PS2/150-140
MI-PS2/1 50-85 304854
286967 22
50
65 60.3
76.1 40
40 66 99 80
80 140
85 250
250 180
190 M12
M12 4.5
4.3 1.8
2.1 3.5
4.2 1.2
1.4 1.2
1.4 MI-PS2/165-85
MI-PS2/1 50-140 286967
304855 22
65
65 76.1
76.1 40
40 66 99 80
80 14085 250
250 190
180 M12
M12 4.3
4.7 2.1
2.1 4.2
4.2 1.4
1.4 1.4
1.4 MI-PS2/165-140
MI-PS2/1 65-85 304855
286968 22
65
80 76.1
88.9 40
40 66 99 80
80 140
85 250
250 180
190 M12
M12 4.7
4.4 2.1
2.4 4.2
4.7 1.4
1.6 1.4
1.6 MI-PS2/180-85
MI-PS2/1 65-140 286968
304856 22
80
80 88.9
88.9 40
40 66 99 80
80 14085 250
250 190
180 M12
M12 4.4
4.8 2.4
2.4 4.7
4.7 1.6
1.6 1.6
1.6 MI-PS2/180-140
MI-PS2/1 80-85 304856
286969 22
80 88.9 40 86 99 80 140 250 180 M12 4.8 2.4 4.7 1.6 1.6 MI-PS2/1100-85
80-140 286969 22
Fixed points

MI-PS2/1
System MQ

100 114.3 40 80 85 250 190 M12 5.3 3.0 6.0 2.0 2.0 304857
and sliders

100
100 114.3
114.3 40
40 88 99 80
80 14085 250
250 190
180 M12
M12 5.3
5.8 3.0
3.0 6.0
6.0 2.0
2.0 2.0
2.0 MI-PS2/1100-140
MI-PS2/1 100-85 304857
286970 22
100
125 114.3
139.7 40
40 88 99 80
80 140
85 250
250 180
190 M12
M12 5.8
5.7 3.0
3.5 6.0
7.0 2.0
2.3 2.0
2.3 MI-PS2/1125-85
MI-PS2/1 100-140 286970
304858 12
125
125 139.7
139.7 40
40 88 99 80
80 14085 250
250 190
180 M12
M12 5.7
6.1 3.5
3.5 7.0
7.0 2.3
2.3 2.3
2.3 MI-PS2/1125-140
MI-PS2/1 125-85 304858
286971 11
125
150 139.7
168.3 40
40 88 99 80
80 140
85 250
250 180
190 M12
M12 6.1
6.1 3.5
4.0 7.0
8.0 2.3
2.7 2.3
2.7 MI-PS2/1150-85
MI-PS2/1 125-140 286971
304859 11
150 168.3
168.3 40
40 88 99 80
80 14085 250
250 190
180 M12
M12 6.1
6.6 4.0
4.0 8.0
8.0 2.7
2.7 2.7
2.7 MI-PS2/1150-140
MI-PS2/1 150-85 304859
286972 11
150
200 168.3
219.1 40
50 88 99 80
100 140
107 250
250 180
180 M12
M16 6.6
8.5 4.0
4.8 8.0
9.5 2.7
3.2 2.7
3.2 MI-PS2/1200-107
MI-PS2/1 150-140 286972
304860 11
200 219.1 50 88 99 100 107 250 180 M16 8.5 4.8 9.5 3.2 3.2 MI-PS2/1200-142
200-107 304860 11
Airconditioning
and Ventilation

219.1 50 100 142 250 180 M16 8.9 4.8 9.5 3.2 3.2 MI-PS2/1 286973
System MQ

200
250 219.1
273.0 50
50 88 99 100
100 142
107 250
250 180
180 M16
M16 8.9
9.5 4.8
5.3 9.5
10.5 3.2
3.5 3.2
3.5 MI-PS2/1250-107
MI-PS2/1 200-142 286973
304861 11
250 273.0
273.0 50
50 88 99 100
100 107
142 250
250 180
180 M16
M16 9.5
9.9 5.3
5.3 10.5
10.5 3.5
3.5 3.5
3.5 MI-PS2/1250-142
MI-PS2/1 250-107 304861
286974 11
250
300 273.0
323.9 50
50 88 99 100
100 142
107 250
250 180
180 M16
M16 9.9
10.5 5.3
5.8 10.5
11.5 3.5
3.8 3.5
3.8 MI-PS2/1300-107
MI-PS2/1 250-142 286974
304862 11
300 323.9
323.9 50
50 88 99 100
100 107
142 250
250 180
180 M16
M16 10.5
10.9 5.8
5.8 11.5
11.5 3.8
3.8 3.8
3.8 MI-PS2/1300-142
MI-PS2/1 300-107 304862
286975 11
300 323.9 50 8 9 100 142 250 180 M16 10.9 5.8 11.5 3.8 3.8  MI-PS2/1 300-142 286975 1
* The maximum permissible loads for connecting components must be taken into account when the pipe support is used!
Firestop systems

* The maximum permissible loads for connecting components must be taken into account when the pipe support is used!

page 26
page 161
page 26
System
Hilti MIMI
Hilti MI - Industrial
industrial
industrial pipePipe
pipe and Electrical
support
support system
system
system Support

MI accessories:
accessories:
and Technical

Individual
Individual connecting
connectingparts
PC Software

parts
Information

Advantages
Advantages
■ Parts
■ Parts designed
designedfor
foreasy
easyassembly
assemblywith
withone
onehand
hand(shaped
(shapedto
(shaped prevent
totoprevent
prevent
rotation).
rotation).
■ “Easy
■ hand”plate
“Easy hand” plate(5)
(5)for
foreasy
easysingle-handed
single-handedadjustment
adjustmentof
adjustment ofof
the
the connection.
connection.
Medium duty

System MM
Light duty

Technical
Technical data
data
Material:
Material: EN-GJMW-400-5
EN-GJMW-400-5asasperperDIN
DINEN
ENEN1562
1562
1562
Medium duty
System MQ

Screws: 8.8 grade


Screws: 8.8 grade
Nuts: 8 grade DIN 1661, self locking
Nuts: 8 grade DIN 1661, selflocking
locking
Galvanizing: 45 µm
Galvanizing: 45 µm

Weight
Weight per Ordering
Ordering designation Item
Itemno. Packege 36,6 36,6
 36,6  36,6
For girder type per designation no. Packege
 
 36,6  36,6
For girder type Weight
set
set [kg] per
[kg] Ordering designation Item no. Packege
contents
contents
Hilti Pipe Rings

set [kg] contents


MI-90 0,16  MIA-EH90 304887
304887 10
10
MI-90 0,16
0,19 MIA-EH90
 MIA-EH120 304887
304888 1010
MI-120  304888 10
MI-120
MI-90 0,19
0,10  MIA-EH120
 MIA-OH90 304888
304889
304889 1010
10 36,6
36,6 36,6
36,6
MI-90
MI-120 0,10
0,13 MIA-OH90
 MIA-OH120
 304889
304890
304890 1010
10 36,6 36,6
MI-120MI-120
MI-90, 0,13
0,28  MIA-OH120
 MIA-EH-P 304890
304891
304891 1010
10 120
120
MI-90, MI-120
MI-90, MI-120 0,28
0,02  MIA-EH-P
 M12-F hex.collar
hex.collar nut
nut 304891
283589
283589 5010
50 120
MI-90, MI-120
MI-90, MI-120 0,02
0,06  M12-F hex.collar nut
 MIA-TP 283589
305707
305707 2050
20 150
150
MI-90, MI-120
MI-90, MI-120 0,06
0,10 MIA-TP screw M12120-F/8.8
 Hex.head M12120-F/8.8 305707
283595
283595 4020
40 M12
M12
150
MI-90, MI-120
MI-120 0,10 Hex.headscrew
screwM12130-F/8.8
M12120-F/8.8 283595 4040
Medium duty

0,11 Hex.head 283596 40 M12


System MQ

MI-90, M12130-F/8.8 283596


MI-90, MI-120
MI-90, MI-120 0,11
0,005 AHex.head screw M12130-F/8.8
13-F washer 283596
304771
304771 10040
100
HDG

MI-90, MI-120 0,005 A 13-F washer 304771 100 M12


M12
M12


 

Examples of applications (cantilever)
(cantilever)  
Examples of applications (cantilever)
Stainless Steel
Medium duty
System MQ

Assembly procedure 95
Assembly procedure 95
95
11 22 127
127
1 2 M12 127
M12
2.
2. M12
2.
M12
M12
M12
2-3x
System MI

2-3x 
 
HDG


 
12,2
12,2xx12,2
1.
1. 72
72
12,2
12,2 x 12,2
1. 72
77
7
Fixed points
System MQ
and sliders

36,6
36,6 36,6
36,6
50 36,6 36,6
50
33 44 50
3 4

1.
1.
Airconditioning
and Ventilation

2.
System MQ

1. 2.
2.
Firestop systems

page 32
page 32
page 162
page 32
17

90.4
90.4
17

90.4
120.4

page 163
System MI - Industrial Pipe and Electrical Support

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
System
Hilti MIMI - Industrial
industrial Pipe
pipe and Electrical
support system Support

Hilti MI industrial pipe support system

Hilti MI-SGC M12


and Technical
PC Software
Information

Hilti
BeamMI-SGC
clamp forM12
various flange
thicknesses
Beam clamp for various flange
thicknesses
Advantages
■ For steel beams with flange thicknesses from 3 to 36 mm and angle
Medium duty

System MM

Advantages
of up to 15°
Light duty

Corrosion
■■ For protection
steel beams of steelthicknesses
with flange beam is notfrom
damaged
3 to 36bymm
beam
andclamp
angle
Beam
■ of up toclamp
15° is equipped with self-locking nut
■ Corrosion protection of steel beam is not damaged by beam clamp
■ Beam clamp is equipped with self-locking nut
2x 2x
2x 2x
Medium duty
System MQ

Technical data
Material:
1x 1x EN-GJMW-400-5 as per DIN EN 1562
Technical data
Galvanizing: Hot-dip galvanized 55 µm
Screw:
Material:
1x 1x EN-GJMW-400-5 as perM12,
DIN 8.8
EN 1562
grade
Galvanizing: Hot-dip galvanized 55 µm
Hilti Pipe Rings

Screw: M12, 8.8 grade


Note
■ The screw must be positioned against the flange of the steel beam
Noteand the wider side of the beam clamp on the base plate of the
■ The screw must be positioned
MI connector positioned against
against the
the flange
flange of
of the
the steel
steel beam
beam
2x 2x ■ and theclamps
Beam wider side
mustofalways
the beam clamp
clampinon
be used
beam the
the base
pairs
on base plate
plate of
of the
the
MI connector
2x 2x ■ Beam clamps must always be be used
used in
in pairs
pairs
Medium duty
System MQ

MI beam clamp for direct connection M12 x 85 - 8.8


HDG

of MI girder to steel beam


MI beam clamp for direct connection M12
M12 xx 85
85 -- 8.8
8.8
of 1xMItypegirder to
For girder steel
Weight
1x beamPackage contents
per set [kg] Ordering designation Item no.
MI-90/MI-120 0.35 16  MI-SGC M12 233859
Package contents Ordering designation Item
Item no.
1x
For girder type
1x
Weight per set [kg] no.
MI-90/MI-120 0.35 16  MI-SGC M12 233859
Stainless Steel
Medium duty
System MQ

30
Items in set :
M12
30
30
Items in set :
M12
M12
System MI
HDG

1x
1x
Fixed points
System MQ
and sliders

1x
Airconditioning
and Ventilation

1x
System MQ

1x 1x

1x 1x
1x 1x
1x
1x
1x 1x 1x
1x 1x
Firestop systems

1x
1x

page 164
page 34
1x 1x
page 34
34
1x
1x
page 1x
1x
SystemHilti
MI -MI
Industrial Pipe
industrial andsupport
pipe Electricalsystem
Support

Hilti MI-DGC

and Technical
PC Software

Information
Beam clamp for direct connection
of MI girder to steel beam

Advantages
■ For steel beams with flange thicknesses from 3 to 36 mm and angle

Medium duty
of up to 15°

System MM
Light duty
■ Corrosion protection of steel beam is not damaged by beam clamp
■ Beam clamp is equipped with self-locking nuts

Technical data
Material: EN-GJMW-400-5 as per DIN EN 1562

Medium duty
System MQ
Galvanizing: Hot-dip galvanized 55 µm
U-bolt: M12, 8.8 grade

Hilti Pipe Rings


Note
■ The U-bolt must be positioned against the flange of the steel beam
■ Beam clamps must always be used in pairs

Medium duty
System MQ
MI beam clamp for direct connection

HDG
of MI girder to steel beam
For girder type Weight per set [kg] Package contents Ordering designation Item no.
MI-90 3.41 4  MI-DGC 90 233860
MI-120 3.65 4  MI-DGC 120 233861 131

Stainless Steel
Medium duty
System MQ
Items in set :

2x 2x
2x 2x

System MI
HDG
1x 1x
1x 1x Fixed points
System MQ

and sliders

Items in set  :

2x 2x
2x 2x
Airconditioning
and Ventilation
System MQ

1x 1x
1x 1x
Firestop systems

page
page165
35
System MI - Industrial Pipe and Electrical Support

page 166
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Hilti MI industrial pipe support system 1x 1x System MI - Industrial Pipe and Electrical Support

1x 1x

Hilti MIC-TRC

and Technical
PC Software

Information
2x Connector for threaded rod
2x 2x
2x
Advantages 2x
■ Easy to install – single-handed installation!
■ Opposite side of MI girder still usable for other applications

Medium duty
1x■ Connector can be used on top or bottom of MI girder

System MM
Light duty
■ With MI-90–30 mm height adjustability (with MI-120 –15 mm)
1x
■ MQ channel fits between MIC-TRC and MI girder
1x
1x 1x

Medium duty
System MQ
2x
Technical data
Material: S235JRG2 as per DIN EN 10025
Galvanizing: Hot-dip galvanized 55 µm
Connecting screws: M12 (connection to MI girder)

Hilti Pipe Rings


1x
MI connector for threaded rods 1x
For girder For thread Weight per Package Ordering
type size 1x set [kg] contents designation Item no.
MI-90/ MI-120 M12 and 1⁄2" 0.982 2  MIC-TRC M12-1⁄2 233856
MI-90/ MI-120 M16 0.893 2  MIC-TRC M16 233857
MI-90: 50
MI-90/ MI-120 M20 and 3⁄4" 1.003 2  MIC-TRC M20-3⁄4 233858 MI-120: 35

Medium duty
System MQ

HDG
Items in set :
1x
1x
75
1x 1x

Stainless Steel
Medium duty
System MQ
1x
1x
1x1x 1x
1x 1x 1x
1x

System MI
Items in set  :

HDG
1x
1x 1x
1x 1x 1x 1x
Fixed points
System MQ

1x
and sliders

1x 1x 1x 1x
1x 1x
1x1x 1x 1x 1x1x 1x
1x 1x 1x 1x
1x
Airconditioning
and Ventilation

Items in set  :
System MQ

1x
Firestop systems

1x 1x

1x 1x
1x

page 38 page 167


System MI - Industrial Pipe and Electrical Support

MI Rigid connector
and Technical

MIC-90-U-ED
PC Software
Information

Advantages
nn Flexibility to compensate tolerances in the dimension of
the building through use of connectors with “telescopic”
charectistics.
Medium duty

System MM
Light duty

nn Easy assembly using push-fit connectors and bolts.


nn Lightweight, thin-gauge girder sections for quick installation
without need for crane transport.
nn Helps make assembly by one person possible.
nn Thin-gauge girder sections can be cut to length on site using
Hilti reciprocating saw.
Medium duty
System MQ

For girder Order Item no.


type designation
Hilti Pipe Rings

MI-90/MI-120 MIC-90-U-ED 431680


Medium duty
System MQ
HDG
Stainless Steel
Medium duty

MI spacing folk MIC-U-EF


System MQ

For girder Order Item no.


type designation

MI-90/MI-120 MIC-U-EF 431682


System MI
HDG

MI Angle connector MIC-U-EL


Fixed points
System MQ
and sliders

For girder Order Item no.


type designation

MI-90/MI-120 MIC-U-EL 431681


Airconditioning
and Ventilation

System MQ
Firestop systems

page 168
Fixed points and sliders.

Hilti. Outperform. Outlast.


Fixed points and sliders

Description Pages

MFP-L light duty fixed point 172

MFP fixed point 173-174

MFP pipe ring 175

MFP roll connectors (galvanized) 176

MSG slide connectors (galvanized) 177

page 171
Fixed
Fixed points
points and and sliders
sliders

MFP-L light-duty fixed point


and Technical
PC Software
Information

Features
■ Verified loads and technical data.
■ Quick installation using only 2 screws on the pipe ring.
■ Narrow flange makes insulation easy.
■ Close spacing possible.
■ Baseplate with acoustic insulation may be used.
Medium duty

System MM
Light duty

We would be pleased to provide technical advice on the design and


installation of fixed points.
1/2", 3/4"
M10, M12, h
s
M16

MFP-L fixed point pipe ring D


b B
Material: QRST 37-2
Medium duty
System MQ

Surface: galvanised, 13 microns


Hex. screws: galvanised, steel strength 8.8
Inch Clamping range, Connection Clamping b×s B h Package Axial load at 150 mm Designation Item no.
size D (mm) boss screws contents F (N)
1
/2″ 21– 22 1
/2″ M10×35 40×6 82 34 20 1000* MFP-L NW15 310307
3
/4″ 25– 27 1
/2″ M10×35 40×6 87 36 20 1000* MFP-L NW20 310308
1″ 33– 35 1
/2″ M10×35 40×6 96 40 20 1000* MFP-L NW25 310309
Hilti Pipe Rings

11/4″ 42– 45 3
/4″ M10×45 40×6 110 45 20 1500* MFP-L NW32 310310
11/2″ 47– 50 3
/4″ M10×45 40×6 116 48 20 1500* MFP-L NW40 310311
2″ 57– 61 3
/4″ M10×45 40×6 130 53 20 1500* MFP-L NW50 310312
68– 72 3
/4″ M12×45 40×6 143 59 20 2000* MFP-L NW68/72 310313
21/2″ 75– 79 3
/4″ M12×45 40×6 150 64 20 2000* MFP-L NW65 310314
3″ 88– 90 3
/4″ M12×45 40×6 162 70 20 2000* MFP-L NW80 310315
4″ 108–115 3
/4″ M16×45 50×6 188 82 10 2000* MFP-L NW4″ 310316
5″ 133–140 3
/4″ M16×45 50×6 214 95 10 2000* MFP-L NW125 310317
Medium duty
System MQ

1/2", 3/4"
150mm

* The loads given apply only in conjunction


HDG

22
with the MFP-GP 1/2″, 3/4″ baseplate ∅ 13,5

F
and HST M12×20 (item no. 70755/4)

Baseplate 150
109
100
Stainless Steel

Material: QRST 37-2


Medium duty
System MQ

Surfaces: galvanised, 13 microns


Connection boss Package contents Axial load at 150 mm (N) Designation
Item no.
1
/2″ 25 max. 2000 MFP-GP /2″ 1
310318
3
/4″ 25 max. 2000 MFP-GP 3/4″ 310319
Threaded connector
Material: ST 37-2 / Surfaces: galvanised
System MI

Type: rolled thread


HDG

Inch size Length, L (mm) Package contents Designation Item no.


1
/2″ 2000 10 GR-G 1/2″ 56428
3
/4″ 2000 5 GR-G 3/4″ 56429
Fixed points
System MQ
and sliders
Airconditioning
and Ventilation

System MQ
Firestop systems

page 172
page 186
Fixedpoints
Fixed pointsand
andsliders
sliders

MFP fixed point:

and Technical
PC Software
A quick and easy installation with

Information
hight versatility from a modular
design.

Medium duty
System MM
Light duty
Medium duty
System MQ
System features

Hilti Pipe Rings


Medium duty
System MQ

HDG
A purely static working princi- Forces in the pipe are trans- Greater installation freedom nents, the MFP2 and MFP3
ple: The axial load is distributed ferred by friction to the pipe and simple fitting: To avoid braces can be pivoted out
in a triangle of forces, reliably ring (up to 10 kN). drilling into rebars when symmetrically. Additional side
transferring the forces into the fastening the bracing compo- bracing can also be installed.

Stainless Steel
Medium duty
System MQ
base material.

System MI
HDG

The pushbutton ensures stepless The brace shoe transfers Other, simple fitting arrange- Loads can be taken up in both
Fixed points
System MQ

and sliders

height adjustment, permitting resulting forces into the base ments can be used for smaller directions by providing bracing
non-problematic subsequent material. It is also suitable for loads due to the modular on both sides.
installation. use with the «MQ» channel design.
installation system.
Other features
Airconditioning
and Ventilation

■ A coordinated programme of rings for pipes from NW15 to


System MQ

■ A system of modular design which is versatile with respect NW250


to height, loading and bracing (packed in sets incl. installation ■ Fixed point sizes designed for load ranges of 3 kN, 10 kN,
instructions). 20 kN
■ Subsequent installation possible without difficulty ■ Stepless height adjustment up to 1200 mm
■ No prefabricating or planning required because the height can ■ System designed for anchors approved for the tension zone
be adjusted on the jobsite All parts galvanized (no subsequent treatment required)
Firestop systems


■ Unproblematic installation by one workman ■ Very strong appearance
■ Economical and clear stockkeeping

Our technical advisory service is available to you for the design of fixed points.

page 173
page 187
Fixed
Fixed points
points and
and sliders
sliders

MFP 1 fixed point set MFP-NW...


and Technical
PC Software
Information

A
Technical Data Bracing shoe

Recommended Load in direction of axial pipe Frec. 3 kN


Support height until overside of pipe H min. = 170 mm 1 1/4"

H max. = 1200 mm M 16
Fastening A = suitable anchor M12 1 H MFP-BP 20
B = suitable anchor M16 1 B
AM 16
M 20
Medium duty

System MM

Ordering designation Box contents Item no.


Light duty

Direc
tion o
f forc
MFP pipe ring as per desired pipe size Frec
e

MFP-BP20 basic set 1 247827


MFP-AP1
MFP-AP1 bracing set 1 247829
Fixed point support 11⁄4 " 1 248532
Medium duty
System MQ

MFP 1a fixed point set


Technical Data MFP-NW...
Recommended Load in 3 kN AHST M 12
direction of axial pipe Frec.
Frec. is decreasing with
increasing support height.
Hilti Pipe Rings

1 1/4"
MFP-BP 20
H

Support height until overside of pipe H min. = 140 mm M20


H max. = 800 mm
Fastening A = suitable anchor M12 1 Frec
Medium duty
System MQ

Ordering designation Box contents Item no.


HDG

MFP pipe ring as per desired pipe size


MFP-BP20 basic set 1 247827
Fixed point support 11⁄4 " 1 248532

MFP 2 fixed point set MFP-NW...


Stainless Steel
Medium duty
System MQ

Technical Data
Recommended Load in direction of axial pipe Frec. 10 kN A
Support height until overside of pipe H min. = 140 mm
H max. = 1200 mm
MFP-BP 20
Fastening A = suitable anchor M12 1
C = suitable anchor M161 C

Ordering designation Box contents Item no.


System MI

MFP pipe ring as per desired pipe size


HDG

MFP-BP20 basic set 1 247827 MFP-AP2


MFP-AP2 bracing set 1 247830
Fixed point support 11⁄4 " 1 248532

MFP 3 fixed point set


Fixed points

MFP-NW...
System MQ
and sliders

Technical Data
Recommended Load in direction of axial pipe Frec. 20 kN
Support height until overside of pipe H min. = 250 mm
H max. = 1200 mm
MFP-BP16
Fastening A = suitable anchor M12 1
Airconditioning
and Ventilation

C = suitable anchor M20 1


System MQ

Ordering designation Box contents Item no.


MFP pipe ring as per desired pipe size
MFP-BP16 basic set 1 247826
MFP-AP3 bracing set 1 247831 MFP-AP3
Fixed point support 11⁄4 " 1 248532
Firestop systems

Given loads only apply if Hilti HST anchors ate used. If the direction of force is not known, or changing, the fixed point must be braced
on both sides. If the force at the fixed point is greater than 10 kN, weld stops on the bracing side of the pipe.

1)
Given values apply only to use of HST anchors. For selection the suitable anchors, our technical support is available for you.

page 174
page 188
page 175
Fixed points and sliders

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
Fixed points and sliders
Fixed points and sliders

MRG roll connector, galvanized


and Technical
PC Software
Information

Features
■ For use suspended or standing without conversion.
■ Coordinated loading classes suitable for Hilti pipe rings.
■ Temperature resistant up to 300°C as no parts are of plastic.
■ Stiffened base plate suitable for MQ channel installation system.

Delivery without nut, screw or washer.


Medium duty

System MM
Light duty

Technical Data
Material: ST 37
Surface: galvanised,13mm Smooth rolling on coated rollers. Large movement: MRG 2 up to 80 mm,
Rolling resistance:  = 0.08 IBMB Nr. Coefficient of friction: µ 0 = 0.08 MRG-D6 up to 116 mm.
3897/1802-4 Center mark for setting to zero.

11,5 x 20
Medium duty
System MQ

MRG 2 roll connector MRG 2


Frec. 2.0 kN, sliding movement 80 mm
80
Connection boss / double thread overall Box Ordering Item no.
height (mm) contents designation
M10 / M12 32.5 5 MRG 2 243550
Hilti Pipe Rings

13,5 x 20
MRG 4 roll connector MRG 4
Frec. 4.0 kN, sliding movement 120 mm
Connection boss / double thread overall Box Ordering Item no. 90
height (mm) contents designation
M12 / M16 39.2 5 MRG 4 243551
Medium duty
System MQ

MRG-D6 double roll connector MRG-D6 ±5


nt mm
8m
m
HDG

e me 116
Frec. 8.0 kN, sliding movement 116 mm c
pla tion
dis c
x. efle
ma ax. d
m 159
Connection boss / double thread overall Box Ordering Item no.
height (mm) contents designation
M12 / M16 43.5 5 MRG-D6 334131
Stainless Steel
Medium duty
System MQ

219
90

13,5 x 20

MRG-D6 UK cross roll connector MRG-D6 UK


System MI
HDG

Frec. 6.0 kN, Rollweg 46 mm


Connection boss / double thread overall Box Ordering Item no.
height (mm) contents designation
M12 / M16 44.5 5 MRG-D6 UK 336755
include 2 screws M12 for connection with MRG-DG UK
Fixed points

13,5 x 20
System MQ
and sliders

200
max. displacement ± 23 mm
max. deflection 46 mm

44,5 60

240
Airconditioning
and Ventilation

Application: MRG-D6 + MRG-D6 UK


System MQ

Connection adapter for roll connector MRG


Outside-thead Inside-thead Box Ordering Item no.
Firestop systems

contents designation
M12 M16 25 MRA M16 252105
M12 3
⁄4 " 25 MRA 3⁄4 " 252106
M12 1
⁄ 2" 25 MRA 1⁄ 2" 252107
M16 1
⁄ 2" 25 MRA 1⁄ 2" M16 338992
M16 3
⁄4 " 25 MRA 3⁄4 " M16 338993

page 176
page 190
Fixed points and sliders
Fixed points and sliders

Slide connector MSG, galvanized

and Technical
PC Software

Information
Benefits
■ Suitable for installation on ceilings or floors
■ Designet for use with Hilti pipe ring programme
■ Resistant to temperatures up to 130° C
■ Small height
■ Slide cannot pull out

Medium duty
System MM
Light duty
Delivery without nut, screw or washer.
Technical Data
Material: ST 37 Built-in plastic slide with a A version for a single connection
Surface: galvanised,13mm smooth movement because no with centering indicator and
Rolling resistance:  =0.18
0.08 angulation is possible installation marking for simple,
Coefficient of friction: µo 0,18 easy and quick installation

Medium duty
System MQ
MSG 1.0 slide connector with single connection 11,5 x 20
Frec 1.0 kN, slide movement = 80 mm
Connection boss overal height Box Ordering Item no.
double thread (mm) contents designation 80
M8 / M10 27 10 MSG 1.0 M8 / M10 248205

Hilti Pipe Rings


M12 / M16 35 10 MSG 1.0 M12 / M16 248206
1
⁄2 " 31.5 10 MSG 1.0 1⁄ 2 " 248207
3
⁄4" 33.5 10 MSG 1.0 3⁄ 4" 248208
11,5 x 20
MSG 1.75 slide connector with two connections
Frec 1.75 kN, slide movement = 94 mm
80

Medium duty
Connection boss overal height Box Ordering Item no.

System MQ
double thread (mm) contents designation

HDG
M8 / M10 27 10 MSG 1.75 M8 / M10 248209
M12 / M16 35 10 MSG 1.75 M12 / M16 248210

m
7m
±4
m ent mm
e 94
lac
isp ion

Stainless Steel
x. d ect
ma . defl

Medium duty
System MQ
x
ma
120

172

System MI
HDG
MSG-1.75 M UK Cross slider element 11,5 x 17

Frec 1.75 kN, slide movement = 54 mm


Fixed points

Connection boss overal height Box Ordering Item no.


System MQ

and sliders

double thread (mm) contents designation


MSG 1.75 M 28 10 MSG 1.75 M UK 337115
include 2 Screws M10 for connection with MSG 1.75
184
max. displacement ± 27 mm
max. deflection 54 mm
Airconditioning
and Ventilation

50
System MQ

28

220
Firestop systems

page 177
page 191
Notes
A breath of fresh air for the
mechanical installation trade.
Hilti. Outperform. Outlast.
Air-conditioning and ventilation

Description Pages

Perforated band hanger and perforated bands 182

Ventilation angels 183-184

Acoustic insulation elements 185-188

page 181
Air-conditioning and ventilation

page 182
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
suspended and in vertical shafts
The exceptional fastening system for rectangular air ducts,
System
Air-conditioning
ML channel

page
page 201
andinstallation

183
ventilation

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
Page 202
7:02 PM

with acoustic insulation for rectangular air ducts


Air-conditioning and ventilation

The easy-to-install suspension system


10/14/08

System ML channel installation


Hilti Installation 1_88

page 184
page 202
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
page 185
Air-conditioning and ventilation

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
Air-conditioning and ventilation

page 186
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Sound absorber for tensile loads
System
Air-conditioning
ML channel

page
page 209
andinstallation

187
ventilation

System MQ System MQ System MQ System MQ System MM PC Software


Airconditioning Fixed points System MI Medium duty Medium duty System MQ Light duty and Technical
Firestop systems and Ventilation and sliders HDG Stainless Steel HDG Hilti Pipe Rings Medium duty Medium duty Information
Sound absorber for compressive loads
System ML channel
Air-conditioning ventilation
and installation

188
page 210
page
PC Software System MM System MQ System MQ System MQ System MQ
and Technical Light duty System MQ Medium duty Medium duty System MI Fixed points Airconditioning
Information Medium duty Medium duty Hilti Pipe Rings HDG Stainless Steel HDG and sliders and Ventilation Firestop systems
Firestop Systems

Hilti. Outperform. Outlast.


Firestop Systems

Tested and
Picture Product Description Application Benefits approved
and Technical
PC Software

according to
Information

Elastromeric • expansion joints and • excellent movement capability BS, UL,


CP 601S firestop sealant connection joints • fast and easy dispensing AS DIN, FM,
Elastic (neutral silicone) • metal pipes up to 200 • cost effective solutions EN
firestop sealant that provides maxi- mm (UL std). • smoke, gas and water tight
mum movement in • good adhesion without use of a
fire rated primer
applications • age tested for 30 years
Medium duty

System MM

• acoustically tested
Light duty

• fire rating up to 4 hours

An acrylic based • rigid or low movement • paintable BS, UL,


CP 606 firestop sealant for joints • fast and easy dispensing AS, DIN, FM,
Fire resistant joint low movement in • metal pipes • smoke, gas and water resistant EN
filler fire rated joints and • excellent acoustic insulation
Medium duty
System MQ

small metal pipe • fast and easy clean up with water


joint • age tested for 30 years
applications

A sprayable fire- • top of wall joints • maximum movement capability UL, FM, BS,
Hilti Pipe Rings

CSF-SP WB rated mastic for • curtain wall/ edge of • can be used with many standard OPL, EN, DIN
Firestop joint spray construction joints slab sprayers
where maximum • expansion joints • water based formulation
movement is • fast and easy clean up with water
required. • resists cracking after installation
• age tested up to 30 years
• tested by recognized clad ding
testing facilities
Medium duty
System MQ
HDG

High expansion • single cables and • wide range of applications BS, AS, DIN,
intumescent mastic cable bunches • paintable EN
CP 611A Intumes- • fast and easy installation and clean up
for • plastic pipes up to
cent firestop • particularly suitable for the laying new cables
penetrations giving 2” (50 mm) with out
mastic • can be used for outdoor applications
up to 4 hours additional collar
protection • metal pipes up to 6” • silicone free
• expansion pressure up to 7 bars
Stainless Steel

(160mm)
Medium duty
System MQ

• age tested for 30 years


• insulated metal pipes • expanding several times original volume
when exposed to heat sealing gaps of
melted components

Intumescent fire • plastic pipes up to 3” • one product for most applications UL, FM
FS-ONE protection for without additional collar • cost effective solutions
High penetrations giving • single cable and cable • fast and easy installation
performance up to 4 hours bunches • can be repenetrated when laying
System MI

intumescent firestop protection • HVAC penetrations new cables


HDG

sealant • metal pipes • paintable


• insulated metal pipes • expansion several times original
volume when exposed to heat
sealing gaps of melted components

Fire-resistant, • large multiple • simple applications by trowel BS, FM, DIN,


Fixed points
System MQ
and sliders

cement-based mor- penetrations • the mortar can be mixed to a stiff AS, UL, EN
CP 636
tar with thermal • single cable, cable consistency, but form work may
Firestop mortar
insulating proper- bunches and cable be required for large penetrations
ties for firestopping trays • paintable
a wide variety of • HVAC penetrations • Age tested upto 30 years
applications • metal pipes
Airconditioning
and Ventilation

System MQ

A fast curing • large multiple • easy to form and apply BS, UL


CP 637 gypsum-based penetrations • can be pumped, poured or trowelled
Structural Firestop mortar for • single cable, cable • paintable
mortar firestopping a bunches and cable • quick setting and remove forms
wide variety of trays within 2 hours
Firestop systems

applications • HVAC penetrations • suitable for light foot traffic (CP 637)
with dampers

page 190
Firestop Systems

Tested and
Picture Product Description Application Benefits approved

and Technical
PC Software
according to

Information
Ready-to-use • plastic pipes with • ready-to-use BS, UL,
CP 643N quickly installed, diameters from 1” (32 • latch mechanism for quick and AS DIN, FM,
Firestop collar galvanized sheet mm) up to 6” (160mm) easy closure without use of a tool EN
steel jacket contain- • flexible tab positioning for
ing sections convenient fastening
of intumescent • allows for correct installation in
material tight areas

Medium duty
System MM
• good acoustic insulation

Light duty
• age tested up to 30 years

Ready-to-use, • plastic pipes from 1.5” • wide range of approvals BS, UL,
CP 644 quickly installed, (50 mm) up to 10” • ready-to-use AS DIN, EN
Firestop collar with snap connec- (250 mm) • snap connection for quick and
tion, steel jacket easy closure without use of a tool

Medium duty
System MQ
containing sections • flexible tab positioning for
of intumescent convenient fastening
material • good acoustic insulation
• age tested up to 30 years

2.1 Simple one step • concrete and metal • one-step firestop solution for UL

Hilti Pipe Rings


solution for fire- deck from 2.5” (64 a variety of pipe materials and
CFS-DID
stopping through mm) up to 12” (305 diameters
Firestop Drop-in
penetration in a mm) • integrated moisture and smoke
Device
variety of base • thick hollow core from seal barrier
materials 7.5” (190 mm) up to • easly identifiable to building
12.5” (318 mm) inspectors
• solution for renovation/ retrofit as
well as new construction

Medium duty
System MQ

HDG
One step firestop- • metal and plastic pipes • one step installation BS, UL,
CP 680 ping of pipes for from 1” (32 mm) up to • no additional caulking AS FM
Cast-in Firestop protection up to 3 6” (170 mm) • ready-to-use
device hours • easy to remove and replace pipe
• allows for pipe adjustments

Stainless Steel
during installation

Medium duty
System MQ
• economical in use owing to short
installation time
• smoke and water tight
• excellent sound insulation

Precut • plastic pipes from • simple to use and easy to cut BS, UL, FM
intumescent graph- 2” (50 mm) up to • easy to fasten on place EN, DIN
CP 648S ite strip 6” (160 mm) • long term stability of installation
Firestop wrap Strip • little space required – ideal where

System MI
pipes run close together

HDG
• ideal for very tight installations
• long length avoids waste
• quick and easy closure without
the use of a tool Fixed points

An • plastic pipes up to • especially suitable for re penetration UL, FM, BS


System MQ

and sliders

intumescent, 12” (300 mm) of new cables EN, DIN


CP 648E Intumes-
flexible firestop • fast and easy installation
cent Endless wrap
wrap for plastic and • no special tools required
Strip
insulated pipe • absolutely dust, fibre, halo gen and
penetrations solvent free
• smoke and gas tight
• immediately functional after
Airconditioning
and Ventilation

installation
System MQ

• age tested up to 30 years

Temporary or • single and cable • especially suitable for re BS, DIN


permanent bunches penetration of new cables
CP658 sealing of single or • fast and easy installation
Firestop plug bunched • no special tools required
Firestop systems

cables in fire walls • absolutely dust, fibre, halo gen and


and floors solvent free
• smoke and gas tight
• immediately functional after
installation
• age tested up to 30 years

page 191
Firestop Systems

Tested and
Picture Product Description Application Benefits approved
and Technical
PC Software

according to
Information

Ready-to-use, • multiple penetrations • especially suitable for re UL


intumescent flexible • cables and cable penetration of new cables
FS 657 brick for temporary trays • easy to install, re-use and re-
Firestop brick or permanent • plastic pipes and metal penetrate
applications pipes • easy to cut and shape
• no special tools required
• smoke and gas resistant
Medium duty

System MM

• age tested up to 30 years


Light duty

Ready-to-use • multiple penetrations • excellent for laying new cables AS DIN,


firestop cushion • cable bunches and • easy to install without use of a EN
CP 651N for temporary or cable trays special tool
Firestop permanent sealing • re-usable
cushion
Medium duty

of cable and cable • tear-resistant and dust-free


System MQ

tray penetrations cushions for dust-free rooms


• temporary or permanent
applications also in drywall
• age tested up to 30 years

The versatile • multiple penetrations • wide application range BS DIN,


Hilti Pipe Rings

seal for a wide • single cable, cable • easy to use in poorly accessible UL, AS, FM,
CP 620 range of firestop bunches and cable openings EN
Firestop foam applications trays • correct installation through fast
• insulated and non- explanation in the opening
• impervious to smoke
insulated metal pipes
• paintable
• combustible pipes in • time saving through few working steps
conjunction with fire • no wastage
stop jackets or wraps • fully cured in 1 minute
• age tested up to 30 years
Medium duty
System MQ

Standard • multiple penetrations • very quick and easy to install BS,


HDG

solution for all • single cable, cable • easy to use in poorly accessible EN
CP 660 small to medium bunches and cable openings
Expanding fire seal sized of openings trays • 3 – phase technology
• insulated and non- • no formwork required
insulated metal pipes • impervious to smoke
• combustible pipes in • sound insulation tested
Stainless Steel
Medium duty
System MQ

conjunction with fire • age tested up to 30 years


stop jackets or wraps

The innovative • multiple penetrations • large penetrations possible up BS, DIN, EN


system for fast, • single cable, cable to 5 m high by any length
CP 670 reliable and bunches and cable • no cracking or delamanation
Fire safety coated cost-effective trays during cutting
board system
System MI

firestopping of wall • insulated and non- • age tested up to 30 years


openings especially insulated metal pipes • sound insulation tested
HDG

large ones • combustible pipes in


conjunction with fire
stop jackets or wraps

A ready-to-use, • single cable • simple application FM


Fixed points

water resistant, • cable bundle • high yield and economical


System MQ
and sliders

CP 678 intumescent • cable tray • easy to clean


Firestop cable cable coating • air ducts and dampers • no derating effects on cables
coating designed to inhibit • pipes • remains flexible when dry
the propagation of
fires along internal
electrical cables
Airconditioning
and Ventilation

System MQ

A ready-to use, • cable bunches and • simple application FM, ABS,


universal fire cable trays • impermeable to water DNV
CP 679A retardant ablative • cable bunches and • for outdoor and indoor
Ablative coating used cable trays applications
firestop cable on cables laid • resistant to oil and petrol spills
coating
Firestop systems

horizontally or • weather proof


vertically. It can be • very flexible when dry
used for indoor or
outdoor applica-
tions

page 192
Hilti Lifetime Service

Outstanding services for a product lifetime.


Tools, always at the ready, with costs under control.

Hilti Lifetime Service is a service package that goes much further than all conventional warran-
ties. When you purchase a Hilti tool you automatically benefit from a comprehensive serrice
model that’s entirely unique in the business.

No costs for up to 2 years Lifetime repair cost limit Lifetime manufacturer’s


warranty
You will bear no repair costs whatsoever After reaching the end of the up to 2-year
for 24 months from the date of purchase. no-cost period, you pay a maximum fixed Hilti repairs or replaces, free of charge,
This includes labour costs, faulty parts and amount. Should the repair cost remain all tools that suffer faults or defects as a
parts subject to wear and tear, servicing below this limit you, of course, pay only result of faulty materials or manufacturing
when indicated by the service indicator on the actual cost of the repair – over the faults – over the entire life of the product.
the tool, functional check - adjustment and entire life of your Hilti tool. Beyond this, as
safety check. added confirmation of Hilti quality, any tool
breakdown within the first 3 months after
every paid repair will be repaired free of
charge as in the first up to 2 year no-cost
period.

No costs Maximum cost Quality without


whatsoever control compromise
page 193
Hilti = registered trademark of Hilti Corp., Schaan I Printed in UAE I © 2012 I Right of technical and programme changes reserved S. E. & O.

Your local Hilti contact:

Hilti. Outperform. Outlast.


No liability accepted for printing errors or other deficiencies: earlier sales catalogues are thus rendered non valid.

S-ar putea să vă placă și