Heated air at 1 atm and 100 F is to be transported in a 400 ft-long circular plastic duct at a rate of
12 ft3/s. If the head loss in pipe is not to exceed 50 ft, determine the minimum diameter of the duct.
Water at 15 C (ρ = 999.1 kg/m3 and µ = 1.138x10-3 kg/m. s) is flowing steadily in a 30 m-long and
4 cm-diameter horizontal pipe made of stainless steel at a rate of 8 L/s. Determine
A) La caída de presión
B) La pérdida de carga
C) El requerimiento de potencia de bombeo para superar esta caída de presión
Consider the flow of oil with (ρ = 894 kg/m3 and µ = 2.33 kg/m.s in a 40 cm-diameter pipeline at an
average velocity of 0.5 m/s. A 300 m-long section of the pipeline passes through the icy water of a lake.
Disregarding the entrance effects, determine the pumping power required to overcome the pressure
losses and to maintain the flow of oil in the pipe.
Considere el flujo de aceite con (ρ = 894 kg / m3 y μ = 2,33 kg / m.s) en una tubería de 40 cm de diámetro a una
velocidad media de 0,5 m / s. Una sección de 300 m de largo de la tubería pasa a través del agua helada de un
lago. Sin tener en cuenta los efectos de entrada, determinar la potencia de bombeo necesaria para superar las
pérdidas de presión y mantener el flujo de aceite en la tubería.
Water at 60 F passes through 0.75 in-internal diameter copper tubes at rate of 1.2 lbm/s. Determine the
pumping power per ft. of pipe length required to maintain this flow at the specified rate.
El agua a 60 F pasa a través de tubos de cobre de 0,75 pulgadas de diámetro interno a una velocidad de
1,2 lbm / s. Determine la potencia de bombeo por pie de la longitud del tubo requerida para mantener este flujo
a la velocidad especificada.