Sunteți pe pagina 1din 3

MOTION ANALYZER DIRECTIONS

Attached is your new C-E Tyler Motion Analyzer for mechanical vibrating

screens . The Motion Analyzer will help you determine the action your machine

is producing .

CIRCLE - THROW VIBRATING MACHINES

Place the Analyzer on the side plate of your machine, as close to the

vibrating mechanism as possible. Locate the circle throw on the Motion Ana-

lyzer that your machine was engineered to produce. This will be your re-

ference circle.

Now start your machine and check its present circular action . . . . ...• .

1. Normal - The reference circle will appear as a uniform

gray circle when the actual vibrating machine's body is

equal to the reference circle on the Motion Analyzer.

2. Over Throw - A White spot will appear in the center of the

reference circle when the actual vibrating machine's circle

is larger than the reference circle on the analyzer.

3. Under Throw - A black spot will appear in the center of the

reference circ le . This black s pot occurs when the machine's

circle is smaller than the reference circle on the analyzer .

HORIZONTAL VIBRATING MACHINES

To check the straight line action of your machine, place the Motion

Analyz er parallel to the top of the side plate.

con' t Pg. /12


Pg . #2

Start your machine and check its ' a ction angle. The ang le line which

a ppears most clearly represents th approximate angle of action . Is your

machine still operating a t the s ame angle as when originally ins talled. Is

t he action a ngle still a near straight l i ne or has it become severly ellipti-

c a l? The l engt h of stroke of your horizonal sc reen c an also be determined

by loca ting the images of the c ircle which a re just t ouching .

If your machine's circle t hrow or s tra i ght line ac tion has changed since

your machine was orig i na lly installed , it cou ld be one of the first signs of

trouble ahead.

Your machine c ould be was ting motion and power, t he correc t throw or

action angle could cause your machine to operate at less than peak eff ic i en cy ,

and bea ring life can be effected.


TYLER
MOTION ANALYZER
\//~
50 55 50 45 ~
40
5" 35
8
3" 1"
1" 5" 2
3'' 16 8
4

• •
16

• •
OVER
THROW
NORMAL •
UNDER
THROW

E E TYLER
MOTION ANA LYZ ER

\//~
45 50 55 50 45 ~
40 40
35 5" 35
8
3" 1"
1" 5" 2
3" 16 8
4

• •
16


• •
OVER
THROW
NORM AL •
UNDER
THROW

S-ar putea să vă placă și