Sunteți pe pagina 1din 2

C1549

Solar Collector Factsheet


NEP PolyTrough 1800
Model PolyTrough 1800
Type Tracking concentrating collector
Manufacturer NEP SOLAR AG
Address Technoparkstr. 1

CH-8005 Zürich
Telephone +41 44 445 1695
Fax +41 43 411 9008
Email contact@nep-solar.com
Internet www.nep-solar.com
Test date 12.2012

 Performance test EN12975:2006


 Quality test EN12975:2006

Dimensions Technical data


Total length 11.085 m Minimum flowrate 900 l/h
Total width 1.965 m Nominal flowrate 1800 l/h
2
Gross area 21.782 m Maximum flowrate 3600 l/h
2
Aperture area 18.450 m Fluid content 9.8 l
2
Absorber area 1.079 m Maximum operating pressure 40 bar
Weight empty 700 kg Stagnation temperature -- °C

Types of mounting Further information


 Construction for sloping roof  Units in different sizes available
 Integration into sloping roof  Glazing replaceable
 On flat roof with stand Hydraulic connection
 Facade Flange DN25 PN40

Construction
1 Glazing
2 Absorber
3 Mirror

SPF Testing, Institut für Solartechnik SPF, Hochschule für Technik Rapperswil HSR, CH-8640 Rapperswil, Switzerland
14.01.2013 / SCFv3.0en www.solarenergy.ch page 1/2
~
C1549
Peak Power per collector unit Wpeak Efficiency η
[W] 12000.0 Solar irradiance G=1000 W/m2 1.0
DNI = 800 W/m2
10000.0 0.8 G = 800 W/m2, (Gb = 680 W/m2, Gd = 120 W/m2)

8000.0
0.6
6000.0
0.4
4000.0

2000.0 0.2

0.0 0.0
*
0 50 100 150 Tm-T200
amb 0 0.05 0.1 0.15 T0.2
m

Peak Power Wpeak 11065 W Reference Aperture, G Aperture,GDNI


Thermal capacity* 7.2 kJ/K η0 0.600 0.689
-1 -2
Flowrate during test 1400 l/h a1 [WK m ] 0.36 0.36
-2 -2
Fluid for test Water a2 [WK m ] 0.0011 0.0011
*) Specific thermal capacity C of the collector without fluid, determined according to 6.1.6.2 of EN12975-2:2006

Incident angle modifier IAM


1.2

1.0

0.8

0.6

0.4

0.2

0.0
0 10 20 30 40 50 60 70 80 θ
90

K1, transversal IAM at 50° 0.93

Collector yield at fixed average collector temperature* (kWh/unit)


Tm Athens Davos Stockholm Würzburg
50°C 17662 16958 11075 10739
100°C 16192 15440 9862 9549
150°C 14551 13806 8588 8347
* Calculated with Solar Keymark Energy Output Calculator v3.10.
Assumption: North-South-axis tracking

SPF Testing, Institut für Solartechnik SPF, Hochschule für Technik Rapperswil HSR, CH-8640 Rapperswil, Switzerland
14.01.2013 / SCFv3.0en www.solarenergy.ch page 2/2