Documente Academic
Documente Profesional
Documente Cultură
ABSTRACT - This research reviews four well-known energy dissipation devices (EDD) used in
practical structural applications and the effect of viscous damper on the behaviour of steel
frames. The response of the one, two and five storey steel frames has been investigated
through a numerical analysis. The seismic response of the frame, the storey displacements,
inter-storey drifts, bending moment in the structural members and natural periods of
vibration with EDD and without EDD were calculated and compared. The results showed
that the EDD can absorb a portion of the energy induced by the earthquake into the structure
and control the displacement of the structural members.
1. INTRODUCTION
Earthquake is on the most damaging disasters. Repairing an area that has experienced an
earthquake is expensive and difficult process. Engineers have introduced different techniques
to prevent a large amount of the damage typically caused by earthquakes. The energy
dissipation devises (EDD) are recognised as a suitable technique to control the seismic
response of the structures and reduce the damages caused by earthquake. EDD can absorb a
portion of earthquake-induced energy in the structure and minimise the energy dissipation
demand on the primary structural members such as beams, columns and walls. These devices
can substantially reduce the inter-story drifts and, consequently, non-structural damage. In
addition, lower accelerations and smaller shear forces lead to lower ductility demands in the
structure components. Many researches have been done on EDD since they have been used to
protect structures from dynamic effects (Soong and Dargush [1], Zhang and Soong [2]).
Zhang and Soong proposed and extended the sequential seismic design method to find the
optimal configuration of viscous dampers for buildings with specified story stiffness. They
used an intuitive criterion to place additional dampers sequentially on the story at which the
inter-story drift response is a maximum. There are many different types of EDD. Each of
these devices has a unique way of dissipating energy and controlling vibrations.
Metallic Damper is one of the most effective mechanisms available for the dissipation of
the energy, induced a structure during an earthquake, through the inelastic deformation of
metals. There are several types of Metallic dampers including Steel Crossing-bracing dampers
Copyright © 2003-2006 Iran Civil Center, All rights reserved worldwide. Page 1 of 8
IranCivilCenter.com - The Construction Industry Portal of Iran
Added Damping and Stiffness (ADAS) dampers, Bell-shaped Steel Dampers, Honeycomb
Dampers System (HDS), Lead Joint dampers and Lead extrusion Damper (LED. These
devices can be installed in bracing system of the structural frame. Figure 1 illustrates the X-
shaped ADAS damper.
Friction devices dissipate energy as heat, caused by the sliding of steel plates against each
other. They generally exhibit rigid plastic behaviour and their force response can be modelled
by simple Coulomb friction, so the force-displacement curves of the devices are rectangular
loops. There are many different friction dampers include, Pall Dampers (Figure 2), Sumitomo
Friction Dampers, Energy Dissipating Restraint (EDR) and Wall Friction Damper. The
advantages of using friction damper over the other types of energy dissipation devices
include:
• These devices have high resistance to fatigue
• Their behaviour is not significantly affected by load amplitude, frequency, the number
of applied load cycles or variations in temperature
• No fluid leaking problems
Copyright © 2003-2006 Iran Civil Center, All rights reserved worldwide. Page 2 of 8
IranCivilCenter.com - The Construction Industry Portal of Iran
orifices through which the fluid may pass one side of the piston to the other as shown in
Figure 4 [6]. The damper thus dissipate energy though the movement of a piston in a highly
viscous fluid using the concept of flow of a liquid through an orifice.
The seismic analysis was performed on 1, 2 and 5 storey steel frames without (bare frame)
and with viscous dampers. Different locations of the EDD in the frame have been considered.
The frames were subjected to earthquake loading using the EC8 simplified method
(Simplified modal response spectrum analysis) [8]. Finite element software (SAP2000 –
Copyright © 2003-2006 Iran Civil Center, All rights reserved worldwide. Page 3 of 8
IranCivilCenter.com - The Construction Industry Portal of Iran
Structural Analysis Programme) was used to carry out the analysis. All the connections
between beams and columns are assumed rigid connections.
The simplest dynamic model, one-storey steel frame as shown in Figure 5, has been
considered in the analysis.
This frame modelled with and without the viscous damper with the properties shown in
Table 1.
Table 1 Properties of the added damper
Element Weight Effective Stiffness Effective Damping
(KN) (KN/m) (KN-S/m)
D 50 2500 10
Table 2 presents the natural period of the frame with and without damper resulted from the
modal analysis. Adding the damper reduced the fundamental natural period by 32%.
However, it does not have a significant effect on period for in the other modes.
Table 2 Natural periods for bare frame and frame with damper
Mode Bare Frame Frame with Damper Reduction
No. Period (Sec) Period (Sec) Ratio
1 1.8625 1.2665 32.00%
2 0.208 0.208 0.00%
3 0.2072 0.2072 0.00%
4 0.0055 0.0054 1.82%
5 0.0044 0.0044 0.00%
The displacement of the joint in the frame with the damper are reduced by over 50%
comparing to the once in the bare frame as shown in Table 3. It can be noticed that the
displacements of the joints 2 and 4 in the bare frame are higher than the allowable limit
required by clause 4.3.2.(a) of Part 1.2 in EC8 (0.024 cm).
Numerical studies on the bending moment of the column in the frame show a reduction of
25% in bending moment
Copyright © 2003-2006 Iran Civil Center, All rights reserved worldwide. Page 4 of 8
IranCivilCenter.com - The Construction Industry Portal of Iran
Table 3 Joint displacement for both bare frame and frame with the damper
Output Displacement Comments Displacement Comments Reduction
Joint
Case along X, bare along X, frame ratio
frame (m) with damper (m)
1 COMB1 0 0
2 COMB1 0.0279 >0.024 Not OK 0.0133 <0.024 OK 52.44%
3 COMB1 0 0
4 COMB1 0.0276 >0.024 Not OK 0.0128 <0.024 OK 53.44%
Analysis on the two-storey steel frame has been done in four different conditions as shown
in Figure 7. The same damper that used in analysis for 1 storey frame was used for this frame.
The natural periods reduced since the damper(s) is installed in the frame and it can be
noticed from Table 4. The maximum reduction is in the fundamental natural period by 27%
and it occurred in Case 3 where two dampers were installed at both floors.
D D
D D
(a) Bare frame (b) Case 1 (c) Case 2 (d) Case 3
Figure 6 2 storey steel frame
Table 5 presents the inter-storey drifts for the bare frame and 3 other cases. In addition, the
reduction ratios in the inter-storey drift for each case are provided.
Copyright © 2003-2006 Iran Civil Center, All rights reserved worldwide. Page 5 of 8
IranCivilCenter.com - The Construction Industry Portal of Iran
Analysis results for two-storey frame show that the inter-storey drift is within the EC8
allowable limit at the same floor at which the damper is installed. Moreover, the inter-storey
drifts at both floors are less than the allowable limit required by EC8 only in Case 3 and they
have been reduced by over 43%.
Analysis for the bending moment in all for conditions show the bending moment in the
column can be reduced by adding the damper between 25% - 38%.
Analysis for a five-storey steel frame was performed in five different conditions, shown in
Figure 8, depending on the properties of the dampers and their location in the frame.
Three different dampers with different properties were used in the analysis. Table 6
presents the properties of these dampers.
D2 D2 D2
D1
D3 D3 D3 D3
(a) Bare frame (b) Case 1 (c) Case 2 (e) Case 3 (f) Case 4
Figure 7 Different cases for five-storey frame
Modal analysis for this frame has been carried out and it shows a significant reduction for
the natural period in some cases as shown in Table 7. The maximum reduction ratio for the
natural period is 20%, which occurred, in the 1st mode of vibration of the Case 4. It can be
noticed that by adding the damper(s) to the frame, it become stiffer therefore the natural
periods reduced.
The inter-storey drifts in all storeys are acceptable by EC8 requirements only in Case 3 as
it shown in Table 9. Although, the inter-storey drift reduced considerably in case 4 at which
dampers are installed in X bracing, this value is higher than the allowable limit by EC8
(0.024m) at the 3rd floor. Comparing Case 2 and Case 3 shows the need of a damper where
the inter-storey drifts is higher than 0.024m.
Analysis results for the bending moment for the columns of this frame show a reduction up
to 46% in bending moment in columns
Copyright © 2003-2006 Iran Civil Center, All rights reserved worldwide. Page 6 of 8
IranCivilCenter.com - The Construction Industry Portal of Iran
4. CONCLUSIONS
One of the objectives of this research was to introduce different types of energy dissipation
devices used for structural applications. EDD significantly increase the resistance of the
structure components to the dynamic loads and they are effective in reducing the seismic
response of structures.
In addition, the effect of the viscous damper at different locations the steel frames has been
investigated. With the proper distribution of the dampers in the frame, engineers can control
the storey displacements in the frame and therefore the inter-storey drift can be reduced
within the EC8 allowable limit. Moreover, viscous dampers slightly reduce the bending
moment resistance demand for the structural member of the frame.
5. ACKNOWLEDGMENT
I would like to appreciate Dr. A.M. Ciupala for her support and her guidance for this
project.
6. REFERENCES
[1]. T.T.Soong, G.F.Dargush, (1997), Passive energy Dissipation Systems in Structural Engineering, John
Willey & Sons Ltd. ISBN 0-471-96821-8
[2]. R.H.Zhang, T.T. Soong (1992), Journal of Structural Engineering, 118 (5), 1375-1392. Seismic design
of viscoelastic dampers for structural applications
[3]. University of Buffalo,
(http://civil.eng.buffalo.edu/technion/Lecture5_12_Devices_and_Models.ppt#311,6,Slide 6)
Copyright © 2003-2006 Iran Civil Center, All rights reserved worldwide. Page 7 of 8
IranCivilCenter.com - The Construction Industry Portal of Iran
Copyright © 2003-2006 Iran Civil Center, All rights reserved worldwide. Page 8 of 8