Documente Academic
Documente Profesional
Documente Cultură
ESSENCE
TECHNICAL DOCUMENT 2009
OF WARMTH
A UNIQUE PRODUCT RANGE
the demands that are made today with regard to an optimal ther-
Flat front panel radiators
mal transfer. This brochure from Brugman presents an unbelievably
large number of possible choices. With its product range, Brugman Bathroom radiators
Conditions of guarantee
BRUGMAN goods are guaranteed for 10 years against any leakages and for 10 years for the paintwork, when they are used in normal circumstances and for a central heating system
with hot water. In case of defects in raw materials or fabrication, recognized by BRUGMAN, BRUGMAN has the right to decide on repair or replacement.
The article has to be sent to us carriage paid, to the exclusion of all labour, transport or relocation costs. BRUGMAN isn’t obliged to any compensation, neither for damages on
other goods, nor for profits lost. Replacement or repair of a radiator, doesn’t extend the guarantee period.
HORIZONTAL HORIZONTAL COLUMN MALTA (RONDO) HORIZONTAL
The manufacturer preserves the right to alter the technical data of its products without prior notice.
STANDARD PIANO UNIVERSAL COMPACT WINDOW IBIZA (RONDO) E-PANEL (CORRUGATED)
COMPACT 4 E-PANEL DESIGN (FLAT)
Taking back the radiators
UNIVERSAL COMPACT VERTICAL
VERTI M PIANO Conditions for the return of undamaged radiators, which are still packaged:
VERTICAL 1. The radiator type has to be part of the existing BRUGMAN programme.
VERTI M STANDARD MINI 2. Stock radiators in the colour white RAL 9016 are taken back at 85% (this means 15% cancellation costs) of the nett-value on the invoice, € 20 transport costs are charged.
VERTI M COMPACT PIANO MINI 3. Non stock radiators, this means radiators with another size or connection than the stock radiators, are NOT taken back, cancellation or credit entry is not possible. Delayed
deliveries do not mean that orders can be annulled. Luxury accessories are not taken back either!
MINI
MINI COMPACT Attention !
Radiators are only taken back after a preceding agreement in writing from BRUGMAN. Don’t send the radiators spontaneously, but wait until a vehicle collects the radiator with
a BRUGMAN collection note.
Cancellation of orders
On receipt of an order especially for non stock items, the orders are immediately taken into production. So the orders can neither be cancelled nor changed.
BRUGMAN cannot be held responsible for possible printing errors and modifications of the programme.
2 3
BRUGMAN PANEL RADIATORS BRUGMAN PRODUCT RANGE OVERVIEW
Stichting STABU has developed a system for the gen- Stabiplan delivers AutoCAD applications for the con-
eration of construction plans, which greatly reduces struction industry. All of the products in this catalogue
the number of steps for the construction planner. The have been included in their applications.
products in this catalogue have been integrated in this
system.
All the products in this catalogue are a suitable for ap-
plications in systems that use low- temperature heating
Vabi is an association active in the automation of (LTH) technology.
construction and installation technology. The prices
contained in this catalogue have been included in their
procedures. EN-442 is the new standard for thermal radiation from
heat exchangers in buildings. All of the products in this
catalogue conform to this standard.
Krijger BV delivers the calculation program Bink, which
has been designed for the construction and installa-
tion sector. The products in our catalogue have been “Het Digitale Huis” structures product information from
included in their program. a construction point of view. The "Het Digitale Huis"
label is therefore a guarantee for professional quality,
“De Zoeksnoek” is a company and product documenta- which is furthermore monitored by independent insti-
tion system in which the usable product information tutes, such as BNA and STABU.
can be found in a very practical way.
BS EN 442
Licence No. 7480
Certified heat outputs
5
PRODUCTION AND QUALITY ASPECTS PRODUCTION AND QUALITY ASPECTS
6 7
PANEL RADIATORS IN DETAIL PANEL RADIATORS IN DETAIL
- 3040
- 2080
- 2400
- 1040
- 1440
- 2240
- 1600
- 2720
- 1200
- 1280
- 1920
- 1760
- 1120
- 640
- 400
- 800
- 480
- 880
- 960
- 560
- 720
The panel radiator in a standard version stands Compact radiators
900 -
out through its excellent quality and ease of Panel radiators in the (Piano-) Universal
700 -
installation. The radiators are provided with 4 600 - Compact range are provided as standard
500 -
connections at the sides, which have a 1/2" in- with 6 connections: 2 on each side and two
Height
400 -
300 -
terior thread, and hanging strips attached by on the bottom on the right-hand side. At the
welding. Through far-reaching innovations in factory, the bottom connections are closed
the processing of convector material and the off with metal caps. In the event that the ra-
geometry of the radiator, the highest possi- diators are connected on the side, the two
Length
ble thermal output is achieved for every size. metal caps close off the bottom connections
Height and length dimension (in mm)
A number of sizes in type 20 are also available Standard / Zinc radiator Compact (4) radiator pressure-tight. By removing these metal
Provided with 4 connections and hanging strips. Finished with a decorative grille and side panels,
in a zinc version. provided with hanging strips and wall brackets. caps, the bottom connections can also be
Type 10 Type 11 Type 20 Type 21 Type 22 Type 33
B B B B B M
b b b b b b used for installation.
Compact (4) radiator The four connections at the side have an in-
The Compact (4) radiator is finished off at the terior thread of 1/2"; the connections at the
Centre to centre
top with a decorative grille, and fitted with (right-hand) bottom of the radiator have a
H
side panels and with hanging strips. 3/4" exterior thread (Eurocone).
tegrated valve system, which means that a Universal Compact radiator Piano-Universal radiator
Finished with a decorative grille, side panels and Finished with a flat front, a decorative grille and with
connection is possible from the side or from provided with six connections. side panels and provided with six connections.
Centre to centre
universal installation characteristics of this ra-
H
diator, there are no hanging strips. Fixing to
the wall is by the use of J brackets or the use
of floor mounting brackets.
8 9
(PIANO) UNIVERSAL COMPACT RADIATOR IN DETAIL (PIANO) UNIVERSAL COMPACT RADIATOR IN DETAIL
Inlet
Details of six connection possibilities Front view of the Universal Compact radiator Connection possibilities for (Piano-) Uni-
A) Traditional connection
Universal and Piano-Universal types are fit- versal Compact radiator
possibility, most fre-
quently used with pipes
ted with an integrated valve system in the The Universal Compact radiator can be con-
3 along the wall.
radiator, whereby the inlet and the outlet 1 Outlet
nected in a traditional manner (see Illustra-
connections are located at the bottom (3/4” tions A, B, C, and D). Furthermore, and in
exterior thread, Eurocone). Besides these the case of floor pipes, it is possible to con-
connection possibilities at the bottom, this nect the pipes directly by means of clamp
Inlet
kind of radiator is also provided with 4 con- fittings to the bottom connections of the
nections at the side (1/2” interior thread). radiator (Illus. E). In such a case, the connec-
B) Diagonal connection, tion possibility that is shown in Illustration D
Z = H -/- 59
usually used for long
Hanging strips and bottom connection radiators. is no longer possible. Whenever the radiator
Universal and Piano-Universal type radiators must be installed in such a way that it can be
are not provided with hanging strips. In this closed off, this can be provided advance by
way, the Universal Compact radiator can be the dealer or can be realised by means of a
reversed, so can optionally be connected at closable connection block. A connection
Outlet
the lower left or right-hand side of the radia- adapter and a number of other accessory
tor. 4 sets can be supplied by the distributor for a
C) Double-sided connec-
2 tion at the bottom. variety of different types.
Attention!!! 6 5
The distance of the lower connection to the Inlet
D) A combination side
Installation connection, usually
used with floor pipes.
Universal Compact and Piano-Universal
Front view of the Universal Compact radiator
radiators can be attached by means of JU
1 1/2” connector with interior thread
brackets. Please refer to the opposite page
2 1/2” connector with interior thread
for applicable connection possibilities of this
3 1/2” connector with interior thread, suitable for valve installation
radiator. n Clamp fitting
4 1/2” connector with interior thread A special adapter for a
Inlet direct connection to a
Outlet
5 3/4” connector with exterior thread (incl. internal Eurocone) (outlet connector) metal or plastic floor
pipe.
6 3/4” connector with exterior thread (incl. internal Eurocone) (inlet connector)
E) Bottom connection, n Connection adapter
used with floor pipes. with Eurocone
Used for a two-pipe Attention!
system. In the case of an connec-
tion adapter application,
n Connection adapter a conical ring has to be
with Eurocone supplied in addition, for a
Used for a one-pipe proper connection to the
system. Eurocone.
Inlet
Outlet
10 11
TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS
Pressure losses Technical specifications: Standard-, (Universal) Compact- and Piano-Universal radiator
* Note: Weights, thermal output and water content are reported per running metre.
** Information in conformity with EN-442; thermal output measured at temperature ranche of 75/65/20°C.
*** See next page for the different types.
Conversion software
12 13
TECHNICAL SPECIFICATIONS THERMAL OUTPUT AT DIFFERENT TEMPERATURES
Thermal output for Standard / Zinc radiators at 75/65/20°C Conversion factors for simplified calculations at 75/60/20°C, at N = 1.30 Because the N-factors of the different panel
Height Type
400 480 560 640 720 800 880 960 1040 1120
Length in mm
1200 1280 1440 1600 1760 1920 2080 2240 2400 2720 3040 TA TR radiators are in the range of 1.30, the ther-
10 TL
11 245 327 409 491 572 654 736 899 1063 1226 1390 1553
TV TR mal output of radiators from the Brugman
20
300 21
22 496 661 826 992 1157 1322 1488 1653 1818 1983 2149 2314 2479 2810 3140
°C °C 12° 15° 18° 20° 22° 24° Casual Line can be easily converted to devi-
33 1187 1425 1662 1900 2137 2374 2612 2849 3087 3324 3562 4036 4511
10 204 273 341 409 477 545 613 682 750 818 886 954 1022
11 316 369 422 474 527 580 633 685 738 791 844 949 1054 1160 1265 1371 1476 1582 1792 2003
80 0.61 0.65 0.68 0.71 0.74 0.77 ating temperatures, by using the correction
20 608 730 851 973 1094 75 0.64 0.68 0.72 0.75 0.78 0.82
400 21
22
497
625
663
833
829
1042
995
1250
1160
1458
1326
1667
1492
1875
1658
2083
1823
2292
1989
2500
2155
2708
2321
2916
2486
3125
2818
3541
3149
3958
90 70 0.67 0.71 0.76 0.79 0.82 0.87 factors present in the table at the left and
33 1201 1502 1802 2102 2403 2703 3003 3304 3604 3904 4204 4505 5105 5706
60 0.76 0.81 0.87 0.91 0.96 1.01
10 250 333 416 499 582 666 749 832 915 998 1082 1165 1248 50 0.87 0.93 1.01 1.07 1.14 1.21 with the formula:
11 319 383 447 511 575 638 702 766 830 894 958 1021 1149 1277 1404 1532 1660 1788 1915 2171 2426 75 0.67 0.71 0.76 0.79 0.82 0.86
20
500 21 591 690 788 887 986 1084 1183 1281 1380 1478 1577 1774 1971 2168 2365 2563 2760 2957 70 0.70 0.75 0.80 0.83 0.87 0.92 P = Pn . f
85
22 620 744 868 992 1116 1240 1364 1488 1612 1736 1860 1984 2232 2480 2728 2976 3224 3472 3720 4216 4712 65 0.74 0.79 0.84 0.89 0.94 0.99
33 1070 1249 1427 1606 1784 1962 2141 2319 2498 2676 2854 3211 3568 3925 4638 55 0.85 0.91 0.98 1.04 1.10 1.16
10 294 392 490 588 685 783 881 979 1077 1175 1273 1371 1469
11 371 445 519 593 667 742 816 890 964 1038 1112 1187 1335 1483 1632 1780 1928 2076 2225 2521 2818 70 0.74 0.79 0.84 0.88 0.93 0.97
600
20
21
510
681 794
680
908 1021
850
1134 1248
1020
1361 1475
1189
1588 1702
1359
1815
1529
2042 2269 2496 2723 2949 3176 3403 80
65 0.78 0.83 0.89 0.94 0.99 1.04 The following is a simplified example of a
22 712 854 997 1139 1282 1424 1566 1709 1851 1994 2136 2278 2563 2848 3133 3418 3702 3987 4272 4842 5411
60 0.82 0.89 0.96 1.01 1.07 1.13
33 1223 1426 1630 1834 2038 2241 2445 2649 2853 3056 3260 3668 4075 4483 5298 50 0.96 1.04 1.13 1.20 1.28 1.37 conversion calculation:
10 65 0.82 0.88 0.95 1.00 1.05 1.11
11 420 504 587 671 755 839 923 1007 1091 1175 1259 1343 1511 1678
20 75
60 0.87 0.94 1.01 1.07 1.13 1.20 The heating requirement for a certain room
700 21 55 0.94 1.01 1.10 1.17 1.24 1.32
22
33
797 957
1358
1116
1585
1276
1811
1435
2038
1594
2264
1754
2490
1913
2717
2073
2943
2232 2392 2551 2870 3189 50 1.10 1.20 1.32 1.42 1.53 1.66 amounts to 1500 Watt, according to the ther-
10 427 498 569 640 711 782 853 60 0.93 1.00 1.08 1.15 1.22 1.29
11 507 609 710 812 913 1014 1116 1217 1319 1420 1522
70
55 0.99 1.07 1.16 1.24 1.33 1.42 mal loss calculation.
20 712 950 1187 1425 50 1.07 1.17 1.28 1.37 1.47 1.58
900 21 923 1076 1230 1384 1538 1691 1845
22 950 1140 1329 1519 1709 1899 2089 2279 2469 2659 2849 40 1.28 1.42 1.59 1.73 1.89 2.08 The desired temperature ranche is set to
33 1588 1852 2117 2382 2646 2911 3176 3440 3705 3970 55 1.05 1.15 1.25 1.34 1.43 1.53
Zinc radiators 65
50 1.13 1.24 1.37 1.47 1.58 1.71 70°C for the inlet temperature, 55°C for the
45 1.24 1.37 1.52 1.64 1.78 1.94
35 1.53 1.73 1.98 2.19 2.44 2.76 outlet temperature and 20° for the ambient
Thermal output for Universal Compact radiators at 75/65/20°C 50 1.22 1.34 1.48 1.59 1.72 1.86
60
45 1.33 1.47 1.65 1.78 1.94 2.13 temperature in the room.
Height Type
Length in mm 40 1.47 1.64 1.86 2.03 2.24 2.50
400 480 560 640 720 800 880 960 1040 1120 1200 1280 1440 1600 1760 1920 2080 2240 2400 2720 3040
20s 269 359 449 539 628 718 808 987 1167 1346
30 1.89 2.19 2.59 2.96 3.44 4.13 According to the table at the left, a correc-
21s 366 488 610 732 855 977 1099 1221 1343 1465 1587 1709 1831 2075 2320 45 1.43 1.59 1.79 1.94 2.15 2.37
300 22
33
472 630 787
1106
945
1327
1102
1548
1260
1769
1417
1990
1574
2211
1732
2432
1889
2653
2047
2875
2204
3096
2362
3317
2676
3759
2991
4201
55 40 1.58 1.78 2.03 2.24 2.48 2.78 tion factor of 1.24 must be applied to these
20s 338 395 451 508 564 620 677 733 790 846 902 1015 1128 1241 1354 1466 1579 1692
35 1.78 2.03 2.36 2.64 2.99 3.43
400
21s 459 612 766 919 1072 1225 1378 1531 1684 1837 1991 2144 2297 2603 2909 40 1.72 1.94 2.25 2.50 2.79 3.15 values.
22 595 794 992 1190 1389 1587 1786 1984 2182 2381 2579 2778 2976 3373 3770 50 35 1.94 2.24 2.63 2.96 3.37 3.92
33 1119 1398 1678 1958 2237 2517 2797 3076 3356 3636 3916 4195 4755 5314
20s 338 406 474 541 609 677 744 812 880 948 1015 1083 1218 1354 1489 1624 1760 1895 2030 30 2.24 2.64 3.19 3.70 4.39 5.39 P = Pn • f
21s 454 545 636 727 818 909 1000 1091 1181 1272 1363 1454 1636 1818 1999 2181 2363 2545 2726 3090 3453
500 22 592 710 828 947 1065 1183 1302 1420 1538 1656 1775 1893 2130 2366 2603 2840 3076 3313 3550 4023 4496
33 999 1166 1332 1499 1666 1832 1999 2165 2332 2498 2665 2998 3331 3664 4331 = 1500 •1.24
20s 394 472 551 630 708 787 866 945 1023 1102 1181 1260 1417 1574 1732 1889 2047 2204 2362
600
21s
22
522
681
626
817
731
954
835
1090
940
1226
1044
1362
1148
1499
1253
1635
1357
1771
1462
1907
1566
2044
1670
2180
1879
2452
2088
2725
2297
2997
2506
3270
2714
3542
2923
3815
3132
4087
3550
4632
3967
5177
= 1860 Watt
33 1146 1337 1528 1719 1910 2101 2292 2484 2675 2866 3057 3439 3821 4203 4967
20s 538 807 897
21s 585 702 819 936 1053 1170 1287 1404 1522 1639 1756 1873 2107 2341
700 22 766 919 1072 1226 1379 1532 1685 1838 1992 2145 2298 2451 2758 3064
33 1280 1494 1707 1920 2134 2347 2560 2774 Explanation of the variables In the thermal output tables of this docu-
20s 558 781 892 1004 P = Standard thermal output according to EN-442, at a desired temperature ranche.
21s 702 842 982 1123 1263 1403 1544 1684 1824 1964 2105
900 22 922 1107 1291 1476 1660 1845 2029 2214 2398 2583 2767
Pn = Standard of thermal output according to EN-442, at 75/65/20°C. mentation, and with a temperature ranche
33 1514 1767 2019 2272 2524 2776 3029 3281 3534 3786 f = Correction factor from the table that accompanies the desired temperature ranche.
of 70/55/20°C, you can select one or more
Thermal output for Piano-Universal radiators at 75/65/20°C panel radiators with a combined total ther-
Height Type
400 480 560 640 720 800 880 960 1040 1120
Length in mm
1200 1280 1440 1600 1760 1920 2080 2240 2400 2720 3040
mal output of approximately 1860 Watt.
20s 252 335 419 503 587 671 755 922 1090 1258
21s 348 464 580 696 812 928 1044 1160 1276 1392 1508 1624 1740 1972 2204
300 22 459 612 765 918 1071 1224 1377 1530 1683 1836 1988 2141 2294 2600 2906
33 1091 1309 1528 1746 1964 2182 2401 2619 2837 3055 3274 3710 4147
20s 314 366 419 471 523 576 628 680 732 785 837 942 1046 1151 1256 1360 1465 1570 Alternatively: If you wish to convert the ther-
21s 432 575 719 863 1007 1151 1295 1438 1582 1726 1870 2014 2158 2445 2733
400 22 572 762 953 1143 1334 1524 1715 1906 2096 2287 2477 2668 2858 3240 3621
33 1099 1374 1648 1923 2198 2472 2747 3022 3297 3571 3846 4121 4670 5220 mal output of a radiator, then you must di-
20s 311 373 436 498 560 622 685 747 809 871 934 996 1120 1245 1369 1494 1618 1743 1867
500
21s
22
425
564
510
677
595
790
680
903
765
1016
850
1129
935
1242
1020
1355
1106
1467
1191
1580
1276
1693
1361
1806
1531
2032
1701
2258
1871
2483
2041
2709
2211
2935
2381
3161
2551
3386
2891
3838
3232
4289
vide the total thermal output by the conver-
33 978 1141 1304 1467 1630 1793 1956 2118 2281 2444 2607 2933 3259 3585 4237
20s 360 432 503 575 647 719 791 863 935 1007 1079 1151 1295 1438 1582 1726 1870 2014 2158 sion factor.
21s 487 585 682 780 877 974 1072 1169 1267 1364 1462 1559 1754 1949 2144 2339 2533 2728 2923 3313 3703
600 22 649 779 908 1038 1168 1298 1427 1557 1687 1817 1946 2076 2336 2595 2855 3114 3374 3633 3893 4412 4931
33 1117 1303 1489 1675 1862 2048 2234 2420 2606 2792 2979 3351 3723 4096 4840
20s
21s 547 657 766 876 985 1094 1204 1313 1423 1532 1642 1751 1970 2189
700 22 730 876 1021 1167 1313 1459 1605 1751 1897 2043 2189 2335 2627 2918
33 1244 1451 1658 1866 2073 2280 2487 2695
20s Conversion software
21s 661 793 925 1057 1189 1322 1454 1586 1718 1850 1982
900 22 884 1060 1237 1414 1590 1767 1944 2121 2297 2474 2651
33 1463 1707 1951 2195 2438 2682 2926 3170 3414 3658
14 15
INSTALLATION AND MAINTENANCE INSTALLATION AND MAINTENANCE
Installation Dimensions of hanging strips for standard radiators Radiator Number of Number of Piano-Universal Compact radiator
A L1 L2 L3
length strips brackets
The packaging of all Brugman radiators is 400 120 160 4 2 The Piano-Universal Compact radiators are
480 120 240 4 2
designed in such a way that damages dur- 560 120 320 4 2 provided with a flat front panel and a 3/4”
640 120 400 4 2
ing the transport, storage and installation of 720 120 480 4 2 connection at the bottom, on the right-hand
800 120 560 4 2
the radiators is prevented, and in principle 880 120 640 4 2 side. For fixing this type of radiator, adjust-
960 120 720 4 2
the packaging should only be removed after 1040 120 800 4 2 able Brugman J-brackets (type JU) are used.
1120 120 880 4 2
installation and before the central heating Type 10, 11 Type 20, 21, 22 Type 33 1200 120 960 4 2 Piano-Universal Compact radiators are not
1280 120 1040 4 2
system is put into operation. 1440 120 1200 4 2 provided with hanging strips.
1600 120 680 680 6 3
1760 120 760 760 6 3 Note: In the case of a left-hand floor con-
Position of the hanging strips for standard radiators 1920 120 840 840 6 3
Maintenance 2080 120 920 920 6 3 nection with Type 33, the distance to the
The illustrations show a rear view of the radiator. 2240 120 1000 1000 6 3
The coating of the radiators is resistant to 2400 120 760 680 720 8 4 wall changes.
2720 120 840 840 800 8 4
standard fluid cleaning agents used for 3040 120 960 920 920 8 4
wall brackets are available as an optional ac- tion with Type 33, the distance to the wall
cessory. changes.
16 17
INSTALLATION AND MAINTENANCE ACCESSORIES
Unistand floor support bracket long Unistand floor support bracket short
Order numbers for Brugman J-brackets
18 19
MANUFACTURING SPECIFICATIONS MANUFACTURING SPECIFICATIONS
Standard radiators Model: Standard radiator Model: Compact radiator Compact-4 radiators
Brugman Standard radiators are Types: 10, 11, 20, 21, 22, 33 Types: 20s, 21s, 22, 33 The Brugman Compact-4 radiators are
manufactured from profile high-qual- Zinc types: 20 Construction height: 300, 400, 500, 600, 700, 900 mm provided with a top grille, with lamel-
ity (DC01) steel which has a thickness Construction height: 300, 400, 500, 600, 700, 900 mm Construction lengths: 400, 480, 560, 640, 720, 800, 880, 960, 1040, 1120, 1200, 1280, las positioned in a lengthwise direc-
of 1.15 mm. The centre-to-centre dis- Zinc construction height: 400, 600, 900 mm 1440, 1600, 1760, 1920, 2080, 2240, 2400, 2720, 3040 mm tion, side panels and four connection
tance between water channels is 40 mm. Construction lengths: 400, 480, 560, 640, 720, 800, 880, 960, 1040, 1120, 1200, 1280, Construction depth: 68, 102, 172 mm points. The Brugman Compact-4 radia-
The surface of the radiators is painted 1440, 1600, 1760, 1920, 2080, 2240, 2400, 2720, 3040 mm Operating pressure: Max. 8 bar tor is manufactured from high-quality
by means of electro-cataphoresic. Dur- Zinc construction lengths: 480, 640, 800, 960 mm Connections: 4 x 1/2" inside thread (at the sides) (DC01) profile steel which has a thickness
ing this procedure they are degreased Construction depth: 50, 102, 172 mm Material: Steel plate, DC01; 1.15 mm thick of 1.15 mm. The centre-to-centre dis-
with an alkaline solvent, treated with iron Operating pressure: Max. 8 bar Surface treatment: Epoxy powder-coating on a cathodic primer tance between water channels is 40 mm.
phosphate and subsequently coated with Connections: 4 x 1/2" inside thread (at the sides) Standard colour: RAL 9016 (white) The surface of the radiators is painted
an environmentally friendly primer. After Material: Steel plate, DC01; 1.15 mm thick Hanging strips: Attached by welding by means of electro-cataphoresic. Dur-
a first hardening process, the radiators are Surface treatment: Epoxy powder-coating on a cathodic primer + zinc Thermal medium: Hot water, up to 110°C ing this procedure they are degreased
provided with an epoxy powder-coating, Standard colour: RAL 9016 (white) Hanging (installation): Brugman VMB brackets (supplied) with an alkaline solvent, treated with iron
after which they are baked. The backside Hanging strips: Attached by welding Brugman J-brackets on request phosphate and subsequently coated with
of the Standard radiator is provided with Thermal medium: Hot water, up to 110°C Shut-off valve/insert: Manually controlled radiator valve; an environmental friendly primer. After a
4, 6 or 8 hanging strips (depending on Hanging (installation): Brugman VMB brackets (on request) thermostatically controlled radiator shut-off valve first hardening process, the radiators are
the length of the unit) that have been Brugman J-brackets, Floor-support brackets (on request) provided with an epoxy powder-coating,
attached by welding. The heat output is Shut-off valve/insert: Manually controlled radiator valve; thermostatically control- Information: Brugman Radiatorenfabriek BV after which they are baked. The backside
measured in conformity with EN-442. led radiator shut-off valve Boskampstraat 26, NL-7561 AM Tubbergen of the Compact-4 radiator is provided
P.O. Box 9, NL-7650 AA Tubbergen with 4, 6 or 8 hanging strips (depending
Zinc radiators Information: Brugman Radiatorenfabriek BV Tel.: +31 (0)546-629320 on the length of the unit) that have been
The radiators of the range ‘zinc radiators’ Boskampstraat 26, NL-7561 AM Tubbergen Fax: +31 (0)546-622645 attached by welding. The thermal output
are zinced separately in a zincery with a P.O. Box 9, NL-7650 AA Tubbergen E-mail: info@brugman.net is measured in conformity with EN-442.
10 µm electrolyte zinc coat. Hereafter Tel.: +31 (0)546-629320
they are passivized through which an Fax: +31 (0)546-622645
excellent corrosion prevention coat ex- E-mail: info@brugman.net
ists. Further the radiators are painted by
the usual procedure, so primed using a
KTL coat and next painted with a powder
coating.
20 21
MANUFACTURING SPECIFICATIONS MANUFACTURING SPECIFICATIONS
Universal Compact radiators Model: Universal Compact radiator Model: Piano-Universal Compact radiator Piano-Universal Compact radiators
The Brugman Universal Compact Types: 20s, 21s, 22, 33 Types: 20s, 21s, 22, 33 The Brugman Piano-Universal Compact
radiators are provided with a top grille, Construction height: 300, 400, 500, 600, 700, 900 mm Construction height: 300, 400, 500, 600, 700, 900 mm radiators are provided with a top grille,
with lamellas positioned in a length- Construction lengths: 400, 480, 560, 640, 720, 800, 880, 960, 1040, 1120, 1200, 1280, Construction lengths: 400, 480, 560, 640, 720, 800, 880, 960, 1040, 1120, 1200, 1280, with lamellas positioned in a lengthwise
wise direction, side panels and six 1440, 1600, 1760, 1920, 2080, 2240, 2400, 2720, 3040 mm 1440, 1600, 1760, 1920, 2080, 2240, 2400, 2720, 3040 mm direction, side panels, a flat front panel
connection points. The Brugman Uni- Construction depth: 68, 102, 172 mm Construction depth: 68, 102, 172 mm and six connection points. The Brug-
versal Compact radiators are manu- Operating pressure: Max. 8 bar Operating pressure: Max. 8 bar man Piano-Universal Compact is stand-
factured from high-quality (DC01) Connections: 4 x 1/2" inside thread (at the sides) Connections: 4 x 1/2" inside thread (at the sides) ardly delivered with a connection at the
profile steel which has a thickness 2 x 3/4" outside thread (at the bottom) 2 x 3/4" outside thread (at the bottom) right-hand side (left-hand connection
of 1.15 mm. The centre-to-centre dis- Material: Steel plate, DC01; 1.15 mm thick Material: Steel plate, DC01; 1.15 mm thick on request). As all other Brugman radia-
tance between water channels is 40 mm. Surface treatment: Epoxy powder-coating on a cathodic primer Surface treatment: Epoxy powder-coating on a cathodic primer tors, the Piano-Universal Compact radia-
The surface of the radiators is painted Standard colour: RAL 9016 (white) Standard colour: RAL 9016 (white) tors are manufactured from high-qual-
by means of the electro-cataphoresis Thermal medium: Hot water, up to 110°C Thermal medium: Hot water, up to 110°C ity (DC01) profile steel which has a thick-
method. During this procedure they Hanging (installation): Brugman J-brackets Hanging (installation): Brugman J-brackets ness of 1.15 mm. The centre-to-centre
are degreased with an alkaline solvent, Floor-support brackets on request Floor-support brackets on request distance between water channels is 40
treated with iron phosphate and subse- Shut-off valve/insert: Manually controlled radiator valve; thermostatically control- Shut-off valve/insert: Manually controlled radiator valve; mm. The surface of the radiators is paint-
quently coated with an environmental led radiator shut-off valve thermostatically controlled radiator shut-off valve ed by means of the electro-cataphoresis
friendly primer. After a first hardening Floor (bottom) Special adapter (clip-on fitting); H-fitting for 1 or 2-pipe Floor (bottom) Special adapter (clip-on fitting); H-fitting for 1 or 2-pipe method. During this procedure they are
process, the radiators are provided with connection: system (with or without shut-off valves) connection: system (with or without shut-off valves) degreased with an alkaline solvent, treat-
an epoxy powder-coating, after which ed with iron phosphate and subsequent-
they are baked. The thermal output is Information: Brugman Radiatorenfabriek BV Information: Brugman Radiatorenfabriek BV ly coated with an environmental friendly
measured in conformity with EN-442. Boskampstraat 26, NL-7561 AM Tubbergen Boskampstraat 26, NL-7561 AM Tubbergen primer. After a first hardening process,
P.O. Box 9, NL-7650 AA Tubbergen P.O. Box 9, NL-7650 AA Tubbergen the radiators are provided with an epoxy
Tel.: +31 (0)546-629320 Tel.: +31 (0)546-629320 powder-coating, after which they are
Fax: +31 (0)546-622645 Fax: +31 (0)546-622645 baked once more. The thermal output is
E-mail: info@brugman.net E-mail: info@brugman.net measured in conformity with EN-442.
22 23
Verti M Standard Verti M Compact
J - Beugel
J-Bracket
Front side Back side
A
59 59
133 133 50 50 L - 266 101 134,5
B
36
Type 10
36
106
36
73
L - 206 Type 21S
50
C
L - 62
1/2” 3/4” 3/4” 1/2”
50
L - 62
D
L - 266
Type 11
50
L - 62
H
H
y
L - 206 Type 22
H Y
1/2” 3/4” 3/4” 1/2”
1600 1564
78
50
L - 62
1800 1764
H A B C D
2000 1964
1600 100 500 900 1345
2200 2164
1800 100 500 1000 1545
78
78
1/2” 3/4” 3/4” 1/2” 22,5 22,5
L
L 64 81,5 2000 100 600 1200 1745
Type 10 Type 11 Type 10 Type 11 2200 100 700 1300 1945
Type 21S Type 22
Suspensions for the Verti are delivered as standard. Suspensions for the Verti are delivered as standard.
NEW! NEW!
WITH CENTRAL WITH CENTRAL
CONNECTION CONNECTION
in conformity with EN-442: radiators and convectors in conformity with EN-442: radiators and convectors
24 25
Verti M Piano Verti M Technical data
J-Bracket
J - Beugel
A
101 134,5
73 106
B
L - 206 Type 21S
C
1/2” 3/4” 3/4” 1/2”
50
L - 62
D
H
L - 206
Type 22
78
L - 62
H A B C D
1600 100 500 900 1345
78
78
Verti M Piano
Type 21s Type 22 Verti M Standard
k Height 1600 1800 2000 2200 1600 1800 2000 2200 Type 10 Type 11
Watt/m 75/65/20 °C 2348 2545 2756 2984 2825 3033 3253 3488 Height 1600 1800 2000 2200 1600 1800 2000 2200
m Length Watt/m 75/65/20 °C 1702 1898 2088 2274 1902 2108 2300 2474
400 939 1018 1102 1194 1130 1213 1301 1395 N-exponent 1,29 1,31 1,33 1,25 1,36 1,32 1,27 1,29
500 1174 1273 1378 1492 1413 1517 1627 1744 Water content l/m 31,58 35,28 38,98 42,76 36,78 40,46 44,16 47,78
600 1409 1527 1654 1790 1695 1820 1952 2093 Weight Kg/m 8,02 8,98 9,96 10,92 8,02 8,98 9,96 10,92
700 1644 1782 1929 2089 1978 2123 2277 2442
800 1878 2036 2205 2387 2260 2426 2602 2790
Verti M Piano
Type 21s Type 22
Height 1600 1800 2000 2200 1600 1800 2000 2200
Watt/m 75/65/20 °C 2348 2545 2756 2984 2825 3033 3253 3488
N-exponent 1,31 1,33 1,35 1,35 1,31 1,32 1,33 1,36
Verti M Piano
in conformity with EN-442: radiators and convectors in conformity with EN-442: radiators and convectors
26 27
BRUGMAN PIANO MINI The Mini in detail
Height- 150 200 able: 150 mm and 200 mm, which can be
Dim./Type 22 33 34 22 33 34
A* 49 49 49 49 49 49 delivered in lengths as of 800, up to and in-
B** 98 167 184 98 167 184
C 100 100 100 150 150 150 cluding 4000 mm (with the exception of the
H 159 159 159 209 209 209
Piano Mini, which is deliverable in a length of
* For the model Piano-2 A + 2 mm is applicable.
** For the model Piano-1 B + 2 mm is applicable; for the model Piano-2 B + 4 mm is applicable.
up to a maximum of 3000 mm).
Installation
Forced water flow for a high thermal radiation. The Mini does not have any hanging strips.
The Mini is mounted either on Brugman
floor brackets or J-brackets. The correspond-
ing brackets must be ordered separately.
Two brackets must be used for lengths of up
to and including 1400 mm, 3‑brackets must
be used as of 1500 mm and 4‑brackets have
to be used as of 2400 mm.
335-340
135-140
Side view of Unistand floor bracket.
29
Mini Compact Piano-Mini
Thermal output table for Mini Compact according to EN-442 Thermal output table for Piano-Mini according to EN-442
Height 150 200 Piano Mini 1 Piano Mini 2
Type 22 33 34 22 33 34 Height 150 200 150 200
Length 75/65/20 75/65/20 75/65/20 75/65/20 75/65/20 75/65/20 Type 22 33 34 22 33 34 22 33 34 22 33 34
800 473 675 787 572 823 964 Length 75/65/20 75/65/20 75/65/20 75/65/20 75/65/20 75/65/20 75/65/20 75/65/20 75/65/20 75/65/20 75/65/20 75/65/20
900 532 760 886 644 926 1085 800 473 678 811 550 809 951 458 662 772 547 799 937
1000 591 844 984 715 1029 1205 900 532 763 913 619 910 1070 516 744 869 616 899 1054
1100 650 928 1082 787 1132 1326 1000 591 848 1014 688 1011 1189 573 827 965 684 999 1171
1200 709 1013 1181 858 1235 1446 1100 650 933 1115 757 1112 1308 630 910 1062 752 1099 1288
1300 768 1097 1279 930 1338 1567 1200 709 1018 1217 826 1213 1427 688 992 1158 821 1199 1405
1400 827 1182 1378 1001 1441 1687 1300 768 1102 1318 894 1314 1546 745 1075 1255 889 1299 1522
1500 887 1266 1476 1073 1544 1808 1400 827 1187 1420 963 1415 1665 802 1158 1351 958 1399 1639
1600 946 1350 1574 1144 1646 1928 1500 887 1272 1521 1032 1517 1784 860 1241 1448 1026 1499 1757
1800 1064 1519 1771 1287 1852 2169 1600 946 1357 1622 1101 1618 1902 917 1323 1544 1094 1598 1874
2000 1182 1688 1968 1430 2058 2410 1800 1064 1526 1825 1238 1820 2140 1031 1489 1737 1231 1798 2108
2200 1300 1857 2165 1573 2264 2651 2000 1182 1696 2028 1376 2022 2378 1146 1654 1930 1368 1998 2342
2400 1418 2026 2362 1716 2470 2892 2200 1300 1866 2231 1514 2224 2616 1261 1819 2123 1505 2198 2576
2600 1537 2194 2558 1859 2675 3133 2400 1418 2035 2434 1651 2426 2854 1375 1985 2316 1642 2398 2810
2800 1655 2363 2755 2002 2881 3374 2600 1537 2205 2636 1789 2629 3091 1490 2150 2509 1778 2597 3045
3000 1773 2532 2952 2145 3087 3615 2800 1655 2374 2839 1926 2831 3329 1604 2316 2702 1915 2797 3279
3200 1891 2701 3149 2288 3293 3856 3000 1773 2544 3042 2064 3033 3567 1719 2481 2895 2052 2997 3513
3400 2009 2870 3346 2431 3499 4097
3600 2128 3038 3542 2574 3704 4338
3800 2246 3207 3739 2717 3910 4579
4000 2364 3376 3936 2860 4116 4820
N-exponent 1,24 1,24 1,24 1,25 1,26 1,26 Water content (l/m) 2,4 3,5 3,5 3,0 4,5 4,5 2,4 3,5 3,5 3,0 4,5 4,5
Max. operating pressure (bar) 8 8 8 8 8 8 Thermal output (W/m) 75/65/20°C 591 848 1014 688 1011 1189 573 827 965 684 999 1171
Max. length (mm) 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000
N-exponent 1,23 1,24 1,25 1,25 1,27 1,25 1,23 1,22 1,22 1,24 1,24 1,25
in conformity with EN-442: radiators and convectors in conformity with EN-442: radiators and convectors
30 31
1000
100
Mini connection possibilities Pressure loss charts
dp(Pa)
10
Also due to the forced water flow, several dif- Inlet Outlet Air vent Order code Verti M Piano 10,11, 21s, 22 This information is based on a standardised installation in accord-
1000
ferent connection variants are possible. The A,C D,B – AB/CD-s (17) 1 ance with EN-442. Pressure loss by way of those shut-off valves has
1 10 100 1000
desired connection possibilities must there- type 10 + 11 not beenm(kg/h)
taken into account.
A B C A/B-s (18) 500
fore be indicated when an order is placed;
dp(Pa)
please consult the diagrams at the left in this C D A C/D-s (19)
Armand (M)
200
regard. Calculation example
10000
Connection variants for series systems
type 21s + 22
Assumption: One Brugman
T1s Verti M type Compact 21s
100
T2s
10 100 100
The Mini models with the order code E/F and 1800 x 600 mm = 1820 Watt
m(kg/h) T1
G/H are supplied with an integrated valve Inlet Outlet Air vent Order code Ta = 75 °C, Tr = 65 °C, Tl = 20 °C
1000
system, which makes a direct installation A D C A/D (10)
Mini
from the floor possible. 1000 T2
C B A C/B (14) 1820 . 3600 6.552000
The same accessories are used for this type qm = = = 74,29 [kg/h]
dp(Pa)
100 100 4200 . 21 88200
of installation, as for the Universal radiators A B C A/B (12)
type 11
dp(Pa)
of the Casual Line. types 22-23
C D A C/D (13)
10 types 33-34-35-36
After consultation of the charts it appears that:
B D C B/D (20) Pressure loss = 110 Pa.
1 10
10 100 1000 1 10 100
D B A D/B (20)
m(kg/h) m(kg/h)
E F A E/F (26)
G H C G/H (25)
100/150 mm
Height
Height
50 27
32 33
ACCESSORIES ACCESSORIES
vertical radiators The towel rail for the Verti M Piano is available in the following widths:
Art. nr.
The multi connection adapter for the Verti M radiator is available in a 400 mm 911980040
right-angled and straight version: 500 mm 911980050
Art. nr. 600 mm 911980060
Right-angled connection adapter with white manual knob 911630151 700 mm 911980070
Right-angled connection adapter with thermostat knob (white) 911630141 800 mm 911980080 Optional: a stainless steel towel rail for the Verti M Piano
Right-angled connection adapter with a thermostat knob (chrome) 911631141
Straight connection adapter with white manual knob 911630157
Straight connection adapter with thermostat knob (white) 911630147 Right-angled connection adapter with white manual knob Right-angled connection adapter with thermostat knob (white)
Straight connection adapter with a thermostat knob (chrome) 911631147 Suspensions for vertical radiators are packed up standard.
H-bloc reversible
34 35
MINI ACCESSORIES STANDARD DELIVERY SCOPE
Mini:
– Colour: RAL 9016
– 6 connections (4 x 1/2" internal thread for
Unistand floor bracket Mini short Unistand floor bracket Mini long side connections; 2 x 3/4" connections
with external thread at the bottom right).
– Environmental friendly and robust
J-brackets: packaging in cardboard with shrink-foil.
Mini Compact Piano Mini
JU for Mini Compact - Piano Mini 1 - – The radiator must be installed on floor
Piano Mini 2 brackets or J-brackets, which must be
150 mm 912099151 ordered separately.
200 mm 912099201
JU
Measurements
Height Model Type M (JS) M (JU) FF FF
22 88 MM MM
150
Mini Compact - 33 88
Piano Mini 1 - 34 88
AND Piano Mini 2 22 88
(JU) 33 88
200
34 88
36 37
Manufacturing specifications Manufacturing specifications
Verti M radiators Model: Verti M Standard (type 10, 11) Mini radiators Model: Mini Compact, Piano
The Brugman Verti M radiators are provided Verti M Compact (type 21s, 22) The Brugman Piano-Mini radiators are provided with a top grille, Types: 22, 33, 34
with a top grille, side panels and a flat front Verti M Piano (type 21s, 22) lamellas that are positioned in a lengthwise direction, side panels, Const. heights: 150, 200 mm
panel. The Verti M Piano comes with 6 con- Const. heights: 1600, 1800, 2000, 2200 and a flat front and back panel. This radiator also provides six uni- Const. widths: 800, 900, 1000, 1100, 1200, 1300,
nections (2 x ½” at the bottom, 2 x ½” at the Const. widths: 400, 500, 600, 700, 800 versal connection possibilities. Exactly as with other Brugman radia- 1400, 1500, 1600, 1800, 2000, 2200,
top; 2 x 3/4” connections with external Euro- Const. depths: 50, 73, 106 mm tors, the Piano-Mini is manufactured from high-quality (DC01) profile 2400, 2600, 2800, 3000, 3200, 3400,
conus MM). Operating pressure: 8 bar steel which has a thickness of 1.15 mm. The Piano-Mini has horizontal 3600, 3800,and 4000 mm (Piano up
After manufacturing, the radiators are thor- Connections: 6 connections water channels and is designed for forced water flow. The radiators to 3000‑mm)
oughly degreased and then immersed in an 2 x ¾” bu Euroconus (central connection MM) are painted by means of the electro-cataphoresis principle. During Const. depth: 68, 102, 172 mm
environmental friendly cataphoresis primer. 2 x ½” bi (at the bottom) this procedure they are degreased with an alkaline solvent, treated Operating pressure: 8 bar
Subsequently, a RAL 9016 paint is applied 2 x ½” bi (at the top) with iron phosphate and subsequently coated with an environmen- Connections: 6 connections (depending on the
by means of electrostatic epoxy-polyester Material: Steel plate, DC01; 1.15 mm thick tal friendly primer. After a first hardening process, the radiators are installed version): 4 x 1/2" internal
powder-coating. All Verti M radiators are Surface treatment: Epoxy powder-coating on a cathodic primer. provided with an epoxy powder-coating RAL 9016, after which they thread (for side connections) and 2 x
carefully packaged and delivered with a set Colour: RAL 9016 white are baked. 3/4" external thread (for connections
of installation material. Hanging strips: welded (only for type 10 and 11) The thermal output is measured in conformity with EN-442. underneath), Euroconus
Thermal medium: Hot water up to 110°C. The Mini type is not provided with hanging strips at the backside. Material: Steel plate, DC01; 1.15 mm thick
Installation: is standard delivered Surface treatment: Epoxy powder-coating on a cathod-
Brugman wall brackets (for type 10 and 11) ic primer.
Brugman J-brackets (for type 21s and 22) Colour: RAL 9016 white
Insert: manual insert, thermostatic regulation Thermal medium: Hot water up to 110°C.
Floor connection: the square and straight adapters are delivered with Installation/Mounting: Brugman floor brackets, J-brackets
integrated valve and M30 exterior thread. or wall brackets on request.
Information: Brugman Radiatorenfabriek BV Shut-off valve: Manually operated radiator valve, or
Boskampstraat 26 a thermostatically controlled radia-
NL-7651 AM Tubbergen tor shut-off valve.
Tel.: +31 (0)546 629320 Floor connection: Special adapter (clip-on connec-
Fax: +31 (0)546 622645 tion), H-fitting for 1- or 2-pipe sys-
Internet: www.brugman.eu tems (closable or non-closable).
E-mail: info@brugman.net Information: Brugman Radiatorenfabriek BV
Boskampstraat 26
NL-7651 AM Tubbergen
Tel.: +31 (0)546 629320
Fax: +31 (0)546 622645
Internet: www.brugman.eu
E-mail: info@brugman.net
Verti M Standard Verti M Compact Verti M Piano Mini Compact Piano Mini
38 39
BRUGMAN BATHROOM RADIATORS Bathroom radiator Ibiza / Ibiza Rondo
1/2" 1/2"
1/2" 1/2"
1/2" 1/2"
1/2" 1/2"
H=1978
* All dimensions in mm.
L
H=1714
94-114 A
Connections
H=1450
34 34 L-120
1/2" 1/2"
H=1186
4 5
H=702
H-174
H-174
87
87
1/2" R 1/2" 1/2" R 1/2" 1/2" R 1/2" 1/2" R 1/2" 1/2" R 1/2" 1 8
77-97 70-80
Ibiza Rondo
Height Width R A Weight Water Electrical Thermal output/Watt (acc. to EN-442) Article
(H) (L) N-exp content heating 75/65 °C 90/70°C number
(mm) (mm) (mm) (mm) (kg) (l) element* 20 °C 22 °C 24 °C 20 °C 22 °C 24 °C RAL 9016
702 446 412 119-129 1.23 6.03 3.20 300 W 316 300 285 393 376 360 50302
702 495 461 120-130 1.22 6.45 3.43 300 W 347 330 313 430 412 395 50312
1186 495 461 120-130 1.20 10.72 5.27 500 W 574 546 519 709 680 652 50352
1186 595 561 126-136 1.20 12.10 6.03 750 W 676 643 611 835 801 768 50362
1450 495 461 120-130 1.23 13.06 6.40 750 W 698 664 629 867 831 795 50392
1450 595 561 126-136 1.23 14.70 7.33 750 W 822 781 741 1021 979 936 50512
1714 495 461 120-130 1.23 15.33 7.51 750 W 823 782 742 1022 980 937 50432
1714 595 561 126-136 1.22 17.24 8.59 1000 W 970 923 876 1203 1153 1104 50442
1714 744 710 136-146 1.22 20.08 10.20 1250 W 1184 1126 1069 1468 1407 1347 50452
1978 495 461 120-130 1.21 17.61 8.61 1000 W 949 903 857 1175 1127 1079 50472
1978 595 561 126-136 1.23 19.78 9.85 1250 W 1118 1063 1008 1389 1331 1274 50482
1978 744 710 136-146 1.25 23.00 11.70 1500 W 1365 1297 1229 1702 1630 1558 50492
41
Bathroom radiator Malta / Malta Rondo Connection possibilities on central heating systems
One-point connections for designer ra- Two-pipe connections for designer radia-
diators tors:
Brugman designer radiators are standardly In principle, three different possibilities exist 2) Hot water supply and return at the top
L fitted with single- and two-point connec- for two-pipe connections. The first possibil- side of the radiator:
1/2” 1/2”
tions, which are suitable both for single pipe ity is a supply and return flow via the con- All designer radiators are standardly pro-
L
and double pipe systems. Single connection nections located at the underside of the ra- vided with a flow pipe in the right-hand
1/2” 1/2”
A
95-115
A point systems can be realised in combina- diator, a second possibility is the supply and collector. In this case, the flow pipe must
113-123
L * All dimensions in mm.
Ø35 Ø35
1/2” 1/2” tion with a single-point control valve, which return via the connections at the top, and a be relocated from the bottom right-hand
H=1782
Connections
4 5 can be delivered by the wholesaler. In case third possibility is a diagonal connection. connection and connected either at the
H=1230
of a single connection-point installation, the right-hand or left-hand connection at the
H=908
H-172
H-172
pre-mounted supply pipe must be removed 1) Supply and return of hot water at the con- top. Important in this connection method is
55-70 56-66 1/2”
R
1/2” 1/2”
R
1/2” 1/2”
R
1/2”
1 8 before a single-point control valve can be at- nections located at the underside of the it that the return must be connected to the
tached. The single-point control valve must radiator: flow pipe.
MALTA MALTA RONDO be provided with a supply pipe that has a All designer radiators are standardly provid-
Malta minimum length of 400 mm. Furthermore, ed with a flow pipe in the right-hand collec- 3) Diagonal connection:
Height Width R A Weight Water Electrical Thermal output/Watt (acc. to EN-442) Article the valve must be installed in such a way that tor. Important for this connection method All designer radiators are standardly pro-
(H) (L) N-exp content heating 75/65 °C 90/70°C number
(mm) (mm) (mm) (mm) (kg) (l) element* 20 °C 22 °C 24 °C 20 °C 22 °C 24 °C RAL 9016 the hot water supply flows into the radiator is that the supply connection is correctly vided with a flow pipe (*) in the right-hand
908 500 460 95-115 1.18 8.50 4.00 500 W 475 453 430 585 561 538 22305
908 600 560 95-115 1.17 9.64 4.54 500 W 562 536 509 691 663 636 22315 by way of this supply pipe. The single-point linked to the flow pipe. If the supply of hot collector. Since a flow pipe does not have to
908 750 710 95-115 1.15 11.35 5.35 750 W 689 657 626 844 811 778 22325
1230 500 460 95-115 1.06 11.25 5.35 500 W 628 601 575 757 730 703 22335 valve can be installed both in the left-hand water is planned for the left-hand side of the be used in the case of a diagonal connection,
1230 600 560 95-115 1.06 12.81 6.09 750 W 741 709 678 893 861 829 22345
1230 750 710 95-115 1.06 15.15 7.20 750 W 909 870 832 1096 1056 1017 22355 and in the right-hand collector. radiator, then the flow pipe must be relo- this pipe must be removed. In the case of a
1782 500 460 95-115 1.21 16.40 7.85 750 W 908 864 820 1124 1078 1032 22365
1782 600 560 95-115 1.20 18.64 8.91 1000 W 1072 1020 969 1325 1271 1217 22375 cated from the right-hand connection to the diagonal connection, the supply of hot wa-
1782 750 710 95-115 1.19 22.00 10.50 1250 W 1316 1253 1191 1623 1558 1493 22385
bottom left-hand connection. ter must always be connected at the top side
of the radiator.
Malta Rondo
* Not for the Project Line and Esterelle
Height Width R A Weight Water Electrical Thermal output/Watt (acc. to EN-442) Article
(H) (L) N-exp content heating 75/65 °C 90/70°C number
(mm) (mm) (mm) (mm) (kg) (l) element* 20 °C 22 °C 24 °C 20 °C 22 °C 24 °C RAL 9016
908 498 450 113-123 1.18 8.50 4.00 500 W 475 453 430 585 561 538 22405 1 2 3
908 597 550 113-123 1.17 9.64 4.54 500 W 562 536 509 691 663 636 22415 R F F
908 746 700 113-123 1.15 11.35 5.35 750 W 689 657 626 844 811 778 22425
1230 498 450 113-123 1.06 11.25 5.35 500 W 628 601 575 757 730 703 22435
1230 597 550 113-123 1.06 12.81 6.09 750 W 741 709 678 893 861 829 22445
1230 746 700 113-123 1.06 15.15 7.20 750 W 909 870 832 1096 1056 1017 22455
1782 498 450 113-123 1.21 16.40 7.85 750 W 908 864 820 1124 1078 1032 22465
1782 597 550 113-123 1.20 18.64 8.91 1000 W 1072 1020 969 1325 1271 1217 22475
1782 746 700 113-123 1.19 22.00 10.50 1250 W 1316 1253 1191 1623 1558 1493 22485
Connection possibilities
for designer radiators.
R = return
F = hot water supply
R F R
Single-pipe valve
42 43
Electrical connection variants Pressure loss charts
Connection for combined use (both elec- 1) Two-pipe connection: 2) Single-point connection: Malta (Rondo) This information is based on a standardised installation in accord-
10000
trical and a central heating installation): The electrical heating element, the hot A single-point valve with a flow pipe is ance with EN-442. Pressure loss by way of those shut-off valves has
Caution! In the case of electrical and combi- water supply pipe and the radiator shut- installed according to the instructions, not been taken into account.
1000
nation installations, the pre-mounted flow off valve are installed according to the either on the left-hand or on the right-
pipe must always be removed. supplied diagram in the optionally of hand collector of the radiator. The elec-
obtainable T-joint, which is screwed into trical heating element is installed in the 100 Calculation example
Connection for 100% electrical use: one of the two collectors, while the re- other collector. An unhindered expan- Assumption: One Brugman Ibiza,
Attention! For electrical connections the turn connector is screwed into the other sion to the expansion tank of the central 10 H 1714 and B 600, Pn = 970 Watt
pre-mounted flow pipe must always be re- collector. The connection dimensions heating system must be guaranteed by Ta = 75 °C, Tr = 65 °C, Tl = 20 °C
moved. For 100% electrical use, the radia- change when an electrical heating ele- way of the drainage pipe, when the shut- 1
1 10 100 1000
tor should be filled with water up to 95% at ment is used (see R = intermediate size off valve of the radiator is closed, for in- m(kg/h) qm = (P x 3600)/(4200 x DT)
maximum. for connections). stance in the summer. --> qm = (970 x 3600)/(4200 x 10) = 83 [kg/h]
1000
100
dp(Pa)
10
Pianoverti 10, 20
1000
Plug ø 1/2” ø 1/2” 1
1 10 100 1000
type 10 m(kg/h)
500
Connection with electrical heating element, for 100%
dp(Pa)
electrical operation.
type 20
Armand (M)
200
10000
T1s
100
T2s
10 100 100
m(kg/h) T1
1000
Mini
1000 T2
dp(Pa)
100 100
type 11
dp(Pa)
types 22-23
*
44 45
Bathroom radiator accessories Bathroom radiator accessories
ResistanceS for mixed use Possible connections for mixed radiators T-piece
Electrical controller with classical resistance One-pipe system
Connection of the central heating: The one-pipe valve with valve-jet pipe must be
• no time regulation on the central connection by way of mounted in the right collector according to our
• regulation of the room temperature standard angular valves instructions. The electrical resistance is mounted in the
• no selection of programmes Resistance: second collector. Via the return tube, a free expansion
• BOOST command (towel drying cycle): 2 hours mounted in the right collector. First the to the expansion tank of the central heating-installation
• anti-frost protection diagonal flow tube (eventually mounted) has to be secured in case of closed radiator valve
• installation in volume 2 or 3 of the bathroom (see image) must be removed. (in summer).
• IPX4 class II Attention:
• thermostat (cable length: 1,2 m) angular valve and thermostatic head are Ref.-nr.: 1668 With connections 1 + 8 as flow and return
• complete thermostat on the radiator RAL 9016 grey not supplied by BRUGMAN. In case of use of an The electrical resistance and the radiator valve are
500 Watt 58208 58201 electrical resistance, the mounted in the chrome plated T-piece 1/2” which
Attention: 750 Watt 58218 58211 connection measures is always delivered with the electrical resistance,
• connection controller (brown=phase, blue=neutral) 1000 Watt 58228 58221 change. according to the scheme. For the other radiators
• double-insulated devices do not have an earth 1250 Watt 58238 58231 Connection of the central heating: First the diagonal with universal connection (1MM8) there is no T-piece
1500 Watt 58248 58241 on connection 18 by way of the flow tube (eventually needed.
T-piece. mounted) must be The connection is screwed in the second collector. The
Resistance: removed. connection can be done in the right collector.
mounted in the right collector.
First the diagonal flow tube (eventually
Standard radio frequent thermostat and radio frequent mounted) must be removed.
receiver with classical resistance
• no time regulation
• regulation of the room temperature Environment of the electrical resistances
• no selection of programmes (diagram volume bathroom)
• BOOST command (towel drying cycle): 2 hours
• anti-frost protection
• installation in volume 2 or 3 of the bathroom (see image)
• receiver (cable length: 1,2 m): IPX4 class II
• thermostat: IP 30 class III
• radio frequency communication between the receiver and the transmitter RAL 9016 grey
500 Watt 58408 58401
Attention: 750 Watt 58418 58411
• connection receiver (brown=phase, blue=neutral) 1000 Watt 58428 58421
• double-insulated devices do not have an earth 1250 Watt 58438 58431 Wall attachments for Project Line
• all combinations of thermostat and receiver 1500 Watt 58448 58441
(radio frequency) are prematched RAL 9016
Ibiza 3969
Ibiza Rondo 3979
Malta 3855
Malta Rondo 3865
Luxury radio frequent thermostat and radio frequent receiver
with classical resistance
• time regulation
• regulation of the room temperature
• 9 programmes are preset, 4 programmes are free
• BOOST command (towel drying cycle): 2 hours
• anti-frost protection
• installation in volume 2 or 3 of the bathroom (see image)
• receiver (cable length: 1,2 m): IPX4 class II
• thermostat: IP 30 class III
• radio frequency communication between the receiver and the transmitter RAL 9016 grey
500 Watt 58308 58301
Attention: 750 Watt 58318 58311
• connection receiver (brown=phase, blue=neutral) 1000 Watt 58328 58321
• double-insulated devices do not have an earth 1250 Watt 58338 58331
• all combinations of thermostat and receiver 1500 Watt 58348 58341
(radio frequency) are prematched
46 47
Standard delivery scope Manufacturing specifications
48 49
Column radiators The Classic Line
51
Production and quality aspects HORIZONTAL RADIATORS
Pre-treatment: Guarantee:
Before the radiators are foreseen with a cata- After delivery, a 10-year guarantee on manu-
phoresis primer coating, they are thoroughly facturing and material deficiencies is grant-
cleaned and pre-treated in a modern spray- ed on all radiators, under the condition that
ing and pre-treatment installation. After this, they have been properly stored, installed by
a treatment with iron phosphate is carried Cleaning and pre-treatment of radiators. trained technicians and have been used un-
out, which guarantees a good adhesion of der normal circumstances.
the cataphoresis primer.
Connections with pipe joints, which are made
by the installer, are always at his own risk!
52 53
Technical data for column radiators Hanging strip plans for column radiators
500
600
300
200
75
110 160 220
25 25
50
N
H
1000
A B C D A
75
20
600
450
1000
N
900
54 55
Technical data for window radiators Hanging strip plans for window radiators
75
– On request, these radiators can be deliv-
25
ered with 3/4", 3/8" or 1/8" connections.
H
25
450
350
600
500
75
A B C D A
90
Front view for figures 5 up to and including 8; side view of Figure 9.
20 N
56 57
Thermal output at different temperatures Accessories
Because the N-factors of the different col- Conversion factors for simplified calculations at 75/60/20°C, at N = 1.26 Fastening materials Loose parts for column and window
radiators.
umn radiators lie in the range of 1.26, the TA TR Suspension brackets: Type LD
TL (Required: 1 suspension bracket for each hanging strip at the top.)
thermal output of radiators from the Brug- TV TR Item no. 912140002
14
man Classic Line can be easily converted to °C °C 12° 15° 18° 20° 22° 24° 6
deviating temperatures, by using the correc- 80 0.62 0.65 0.69 0.72 0.75 0.78
75 0.65 0.69 0.73 0.75 0.79 0.82 20
tion factors present in the table at the right 90 70 0.68 0.72 0.76 0.79 0.83 0.88
20 80
60 0.76 0.81 0.87 0.91 0.96 1.01 5/4”
and with the formula: P = Pn • f 50 0.87 0.94 1.01 1.07 1.13 1.21 35
75 0.68 0.72 0.76 0.79 0.83 0.87 25
70 0.71 0.75 0.80 0.84 0.88 0.92 Blind plug (galvanised)
85
65 0.75 0.79 0.85 0.90 0.94 0.99
55 0.85 0.91 0.98 1.04 1.09 1.16 Radiator
Right-hand thread Left-hand thread
70 0.75 0.79 0.85 0.89 0.93 0.98 Spacer: Type LW connection with:
The following is a simplified example of a 80
65 0.79 0.84 0.90 0.94 0.99 1.04 (Required: 1 spacer for each strip at the bottom.) Item no. 912150200 912150100
60 0.83 0.90 0.96 1.01 1.07 1.13 Item no. 912140003
conversion calculation: 50 0.96 1.04 1.13 1.19 1.27 1.36 G
65 0.83 0.89 0.95 1.00 1.05 1.11 25
The heating requirement for a certain room 75
60 0.88 0.94 1.01 1.07 1.13 1.19
55 0.94 1.01 1.10 1.16 1.23 1.31
14
amounts to 1500 Watt, according to the ther- 50 1.09 1.19 1.31 1.40 1.51 1.63
60 0.93 1.00 1.08 1.14 1.21 1.28 30
60
In the thermal output tables of this docu-
60
60
min 125 - max 175
58 59
E-PANEL E-PANEL DESIGN
HORIZONTAL
Weight Weight Electrical
Width Height Depth Art. n. Art. n.
corrugated flat output
(mm) (mm) (mm) corrugated flat
(kg) (kg) (Watt)
500 600 73 16,80 19,27 750 5950001 5950004
800 600 73 26,88 30,83 1000 5950002 5950005
1000 600 73 33,60 38,54 1500 5950003 5950006 E-Panel E-Panel
horizontal corrugated horizontal flat
in conformity with EN-442: radiators and convectors in conformity with EN-442: radiators and convectors
60 61
NOTES NOTES
62 63
We reserve the right to make technical changes. Version 03/2009
Brugman Radiatorenfabriek BV
Boskampstraat 26, 7651 AM Tubbergen,
Postbox 9, 7650 AA Tubbergen
Tel: +31 (0)546-629320, Fax: +31 (0)546-622645
Internet: www.brugman.eu - www.theheatingcompany.com
E-mail: info@brugman.net - info@theheatingcompany.com