Comment:1
Response: 1
=169.02 / 95.88=1.76
Since, nominal capacity of column is greater than 1.25,
So, no immediate props are required.
[Note: it is observed that for point-15, calculated value is 1.24 as per sent pdf. But in calculation it is shown that
value is 1.76.]
=169.02 / 136.22=1.24
Since, nominal capacity of column is less than 1.25,
Response: 2
Hence, okay.
Comment: 3
No calculation is provided for punching in the grade beam though props is proposed from the grade beam
Response: 3
THERE IS NO NEEDED TO CHECK PUNCHING WHERE THERE IS BEAM. SHEAR CHECK CAN BE OKAY
FOR BEAMS.
Design Shear strength for concrete, phi*Vc= 2*phi*√f’c*bd = 2* 0.85*√1926*10*9.5 = 7.09 kips.
4 = (0.22*40000*9.5)/(Vu-7.09)
For grid 6B the props layout is incomplete. Also how the props will be connected with the beams is not
mentioned.
Response: 4
ACAD WORKS.
The props will be connected with beams with base plate surrounding nos. of bolts.