Sunteți pe pagina 1din 4

switch:user> nodefind 20:00:00:e0:8b:01:ce:d3

NL 020eef;3;20:00:00:e0:8b:01:ce:d3;20:00:00:e0:8b:01:ce:d3;
Port Index: 14

cfgactvshow

alicreate
alidekete
aliremove
alishow

zonecreate 'zonename" ,"zone members "

cfgsave "cfgname"
cfgenable "cfgname"

zonedelete
zoneremove
zoneshow

cfgshow "*"

zoneobjectrename "objectoldname","newname"

fabricshow
fabricname --show

switchshow [-slot slot] -portname

zoneshow

cfgsize To display Admin Domain and zone database size information

cfgtransabort Aborts the current zoning transaction.


cfgTransShow To display the current transaction:

islshow Displays interswitch link (ISL) information.

configupload Uploads system configuration data to a file. configupload [-all] [-p


ftp | -ftp] ["host","user","path" [,"passwd"]]

configupload -ftp 192.168.38.245, \jdoe,config.txt,password

portcfgshow [slot/]port Use this command to display the current configuration of a


port.
portcfgspeed [slot/]port speed Configures the speed for a port or a range of
ports.

portname [slot/]port [-n name] Assigns or displays port names.


porttest Performs a functional test of a switch in a live
fabric.
porttestshow [-ports itemlist] Displays information from portTest.
stopporttest [-ports itemlist] Terminates the running portTest.

sensorshow Displays sensor readings.


sfpshow [slot/]geport [ -f] Displays Small Form-factor Pluggable (SFP)
information.
sfpshow -health

slotshow [-m] [-p] Displays the status of all slots in the system.

spinfab [-ports itemlist] Runs functional test of interswitch link (ISL)


cabling and trunk group operation.
Use this command to verify the intended functional
operation of interswitch links (ISLs) at the maximum
speed by setting up the routing hardware so that
test frames received by each E_Port are retransmitted on the same E_Port.

portCfgTrunkPort to enable or disable trunking on a single port.


switchcfgtrunk mode Enables or disables trunking on all the ports of a switch.

switchstatusshow Displays overall switch status.


switchuptime Displays the amount of time the switch has been operating.

version Displays firmware version information.

zoneObjectCopy "objectName", "newName" Use this command to make a copy of an


existing zone object and give it a new name

N_Port ID Virtualization (NPIV) enables a single Fibre Channel protocol port to


appear as multiple,
distinct ports, providing separate port identification within the fabric for each
operating system image
behind the port as if each operating system image had its own unique physical port.
NPIV assigns a
different virtual port ID to each Fibre Channel protocol device without impacting
your existing hardware
implementation. The virtual port has the same properties as an N_Port and is
therefore capable of
registering with all fabric services
====================================================

aaaconfig --show
ad --transabort Aborts the transaction buffer. The command prompts for
confirmation before aborting the transaction.
ad --transshow Displays the ID of the current Admin Domain transaction and
indicates whether or not the transaction can be aborted. The transaction cannot be
aborted if it is an internal Admin Domain transaction.
The Admin Domain transaction buffer is linked to the current login shell and is
lost on logout. Use the
--transshow option to display the current Admin Domain transaction information.

clihistory : To display the command history on a switch:

configlist -local /-USB | -U To display a list of configuration files stored on the


local chassis:

configshow Displays system configuration settings.


-switch
Displays the switch configuration only. This option is valid
only in a Non-Virtual Fabric environment.

defzone [--noaccess | --allaccess | --show] Sets or displays the default zone


access mode.
diagshow [--slot number][-uports itemlist][-bports itemlist] [-use_bports value]
Displays diagnostics status.

enclosureshow attribute Displays attributes of the switch enclosure.

errshow [-a | -r] Displays the error log messages with pagination.

fabricprincipal [--show | -q]

fabstatsshow Displays fabric statistics.

fcping [source] destination ------Sends a Fibre Channel Extended Link Service


(ELS) Echo request to a pair of ports or to a single destination, or executes a
SuperPing

framelog --show [-txport [slot/]port] Displays information about discarded frames.

portfencing --show
portperfshow [[slot/]port1[-[slot/]port2]] [-tx -rx | -tx | -rx] [-t interval]]
Displays port throughput performance.
portstatsshow [slot/]port Displays port hardware statistics.
portrouteshow [slot/]port Displays routing tables for the specified port.
portShow Displays status and configuration parameters for ports and GbE ports.
portloginshow [slot/]port Displays port login status of devices attached to the
specified port.

fdmishow Use this command to display FDMI information for all HBAs and ports.

fcpprobeshow [slot/]port Displays the Fibre Channel Protocol (FCP) probe


information

interfaceshow [slot/][port] Use this command to display the two data structures
associated with FSPF interfaces (E_Ports) on the switch:

licenseshow Displays current license keys.

linkcost [[slot/]port [cost]] Sets or displays the Fabric Shortest Path First
(FSPF) cost of a link.
Use this command to set or display the cost of an
interswitch link (ISL). The cost of a link is a
dimensionless positive number. The Fabric Shortest
Path First (FSPF) protocol compares the cost of
various paths between a source switch and a
destination switch by adding the costs of all the ISLs along each path.

nsaliasshow [-r ][-t] Use this command to display local name server
information with the added feature of displaying the defined configuration aliases
to which the device belongs
nscamshow [-t] Displays information about remote devices in the Name Server (NS)
cache.
nsshow [-r][-t] Use this command to display local NS information about devices
connected to a switch
nszonemember pid | wwn To display information about all the online devices zoned
with the given device:
nszonemember -u To display all the unzoned devices in the fabric:
pathinfo destination_switch [source_port[destination_port]] [-r] [-t] Displays
routing information and statistics along a path covering multiple switches.
portCfgNPIVPort --attributes Enables or disables N_Port ID virtualization (NPIV)
functionality on a port and sets the per-port login limit.

portswapshow Displays the state of the PortSwap feature.

fcpprobeshow [slot/]port Displays the Fibre Channel Protocol (FCP) probe


information.
portLogShow [count[, saved]] Displays the port log with page breaks.

portfencing --show Use this command to enable or disable the Fabric


Watch port fencing feature for specified port types and
Fabric Watch areas. Supported port types include
E_Ports, optical F_Ports, copper F_Ports, physical ports, and Virtual E_Ports
(VE_Ports)

portLoopbackTest [--slot slot] Performs a functional test of port N->N path.,


Use this command to verify the functional operation of the switch.

porttrunkarea --show slot/port1[-port2] display masterless F_Port trunking


information

trunkshow [-perf] Use this command to display trunking information of both


E_Ports and EX_Ports

wwn [-sn] Displays the world wide name (WWN) and factory serial number of the
switch or chassis.
licenseidshow To display the license ID:
chassisshow

S-ar putea să vă placă și