Sunteți pe pagina 1din 6

Webmail - Read Message http://mbox.engineeringautomation-ng.com/readmessage.php?msg=892...

Green theme

Inbox Compose Address Book Options Help Log Out

aloysius.iwok@engineeringautomation-ng.com

Read Message - Inbox Previous Next

From: magnus.okoye@engineeringautomation-ng.com (Added to Address Book)

To: aloysius.iwok@engineeringautomation-ng.com <aloysius.iwok@engineeringautomation-ng.com>

Sent: Oct 03 '17 13:42

Subject: FW: Erha Piping Repairs - Request for Quote

Encoding: Unicode, Worldwide ( UTF-8 )

Reply Reply All Forward Forward as Attachment Delete Print View Source Download Show Headers Mark as Unread Put in Folder

Regards,
Okoye, Magnus Chukwudi
Engineering Automation Technology LTD
Ikot Idoma,
Eket
Akwa Ibom State
phone:07084595204

-------Original Message-------
From: Ezikpe Chima <chima.ezikpe@engineeringautomation-ng.com>
To: magnus.okoye@engineeringautomation-ng.com
Cc: ndifreke.ekanem@engineeringautomation-ng.com
Subject: FW: Erha Piping Repairs - Request for Quote
Sent: Oct 03 '17 11:18

Ezikpe, Chima Raphael

Manager

Asset Integrity Management Department


Engineering Automation Technology LTD
Ikot Idoma
Eket
Akwa Ibom State
+2348028905615

"This email, any attachment and response string are confidential and may be legally privileged. If you are not the intended recipient,kindly notify the sender by return m ail and delete this
message and any attachment immediately. Please do not copy, forward or use the message or attachment except as permitted by the author"

From: Orhue, Osahon [mailto:osahon.orhue@exxonmobil.com]


Sent: Monday, October 02, 2017 10:33 AM
To: 'chima.ezikpe@engineeringautomation-ng.com'
Subject: FW: Erha Piping Repairs - Request for Quote

Chima – I have included the Operating pressures (highlighted in yellow int e table). Also highlighted is the defect location and not a guess work as alluded in Kahl’s (Pi pewrap) email

From: Ezikpe Chima [mailto:chima.ezikpe@engineeringautomation-ng.com]


Sent: Monday, October 2, 2017 10:15 AM
To: Orhue, Osahon <osahon.orhue@exxonmobil.com>
Subject: FW: Erha Piping Repairs - Request for Quote

Osahon,

See mail below.

My engineering team require us to send them the operation pressures.

Please treat as urgent.

Thanks

Ezikpe, Chima Raphael

Manager

1 of 6 13-Oct-17, 3:06 PM
Webmail - Read Message http://mbox.engineeringautomation-ng.com/readmessage.php?msg=892...

Asset Integrity Management Department


Engineering Automation Technology LTD
Ikot Idoma
Eket
Akwa Ibom State
+2348028905615

"This email, any attachment and response string are confidential and may be legally privileged. If you are not the intended recipient,kindly notify the sender by return m ail and delete this
message and any attachment immediately. Please do not copy, forward or use the message or attachment except as permitted by the author"

From: Emerson Kahl [mailto:Emerson.Kahl@milliken.com]


Sent: Friday, September 29, 2017 5:46 PM
To: Ezikpe Chima; Jim Souza; Casey Whalen
Subject: RE: Erha Piping Repairs - Request for Quote

I cannot provide calculations without operating pressure. Also description of the defect location will be guess work.

Emerson Kahl
Operations Manager

Milliken Infrastructure Solutions


15832 West Hardy Rd. Suite 600
Houston, Texas 77060
T 281.999.7100 ext. 316/ C 281.253.8601

emerson.kahl@Milliken.com

From: Ezikpe Chima [mailto:chima.ezikpe@engineeringautomation-ng.com]


Sent: Friday, September 29, 2017 10:43 AM
To: Emerson Kahl <Emerson.Kahl@milliken.com>; Jim Souza <Jim.Souza@Milliken.com>; Casey Whalen <Casey.Whalen@Milliken.com>
Subject: FW: Erha Piping Repairs - Request for Quote

Ek,

Please see mail below.

Can you provide ED for the 21# lines?

I am not able to fill a questionnaire immediately and the Exxon wants it asap.

Thanks

Ezikpe, Chima Raphael

Manager

Asset Integrity Management Department


Engineering Automation Technology LTD
Ikot Idoma
Eket
Akwa Ibom State
+2348028905615

"This email, any attachment and response string are confidential and may be legally privileged. If you are not the intended recipient,kindly notify the sender by return m ail and delete this
message and any attachment immediately. Please do not copy, forward or use the message or attachment except as permitted by the author"

From: Orhue, Osahon [mailto:osahon.orhue@exxonmobil.com]


Sent: Thursday, September 28, 2017 9:32 PM
To: 'chima.ezikpe@engineeringautomation-ng.com'
Cc: 'emmanuel.okon@engineeringautomation-ng.com'; Olumide, Iyiola; Egobor, Noah /C; Olorunniyi, Emmanuel /C; Okotor, Dominic O; Akpan, Mfon R; Kareem, Saheed O
Subject: RE: Erha Piping Repairs - Request for Quote

Chima,

Find below 21# list of pipes with their defects characteristics. Kindly furnish us with repair quotes to enable us progress PO release for site visit for scope verificati on, detailed engineering and
wrap repairs.

2 of 6 13-Oct-17, 3:06 PM
Webmail - Read Message http://mbox.engineeringautomation-ng.com/readmessage.php?msg=892...

Please note as can be seen from trail mail, that S/# 1 – 16 was sent to you earlier without the defect lengths and type and their rehabbed pressures were provided by EATE CH/Pipewrap.

Dominic – Please provide screened notification number and get Maintenance planner to convert to WO these composite piping repairs as they are the black piping list for Er ha Nov SD
intervention

Operating
Nominal Min Wall Design # of
Scope SIZE % Wall Pressure Defect
S/N Line # WT Thickness Pressure Repair Defect Location
# (IN) Loss (psig) Length (ft)
(mm) (mm) (psig) Locations

3800
1 TS3 2"-1KD-ZN-651126-G5 2 11.1 3.1 72% 5805 2 2 1# Tee i.e 2"x24" Tee, 1# Straight pipe
3800
2 TS14 2"-1KD-ZN-651128-G5 2 11.1 3.5 68% 5805 4 2 3# Straight pipe; 1# 90deg elbow
3800 2# elbow (1ft each); 2# straight pipe (1ft
3 TS16 2"-1KD-ZN-651265-G5 2 11.1 5.5 50% 5805 4 4
each)
1450 2# straight pipe (0.5ft each); 1# of the
4 TS17 2"-1KD-DC-661052-E1 2 8.7 3.2 63% 2220 2 1
location is on 1" bypass
1450
5 TS18 3"-1KD-DC-661058-E1 3 11.1 2.3 79% 2220 2 2 2# straight pipe (1ft each)
1450
6 TS19 2"-1KD-DC-661061-E1 2 8.7 1.6 82% 2220 5 3 1"x2" Tee, 4# straight pipe
1450 3# elbows; 1# 2"x1" weldolet; 1# straight
7 TS20 2"-1KD-DC-661062-E1 2 8.7 2.7 69% 2220 5 2.5
pipe
2600
8 TS22 2"-1KD-TR-651010-F5 2 11.1 3.7 67% 3480 2 2 1# elbow (1ft); 1# clamped elbow (1ft)
1450 1# Tee (1ft); 1# elbow (1ft); 1# straight
9 TS26 2"-1KD-DC-661134-E1 2 8.7 3.3 62% 2220 3
pipe (1ft)
2600
10 TS28 2"-1KD-DC-651213-F5 2 11.1 3.2 71% 3480 1 0.5 Straight pipe

11 TS29 2"-1KD-DC-651045-F5 2 11.1 2.9 74% 2600 3480 2 2 1# elbow; wrap over 1# clamp
3800
12 US3 2"-1KD-ZN-651264-G5 2 11.1 3.8 66% 5805 3 3 1# elbow (1ft); 2# straight pipe (1ft each)
2650
13 US5 3"-1KD-GX-651096-F5 2 11.1 3.9 65% 3480 2 1 1# elbow (0.5ft); 1# Tee (0.5ft)
3800
14 US6 2"-1KD-GX-651099-G5 2 11.1 6.8 39% 5805 1 1 1# straight pipe

15 US7 3"-1KD-GX-651118-F5 3 15.2 3.1 80% 2550 3480 2 2 2# straight pipe (1ft each); 1# elbow (1ft)
3750
16 US8 2"-1KD-GX-651120-G5 2 11.1 2.9 74% 5805 2 2 2# straight pipe (1ft each)

150
17 TS5 1"-LD-DC-623226-A1 1 6.4 1.2 81% 285 1 0.5 1# Tee (8"x1")

18 TS6 4"-LD-DC-623101-A1 4 6 2.3 62% 150 285 3 1.5 2# elbows (5.5ft each); 1# Tee (0.5ft)

19 TS7 4"-LD-DC-623103-A1 4 6 2.3 62% 150 285 3 1.5 3# elbows (0.5ft each); 1# Tee 8"x4" (0.5ft)
400 4# elbows (1ft each); 3# straight pipe (1ft
20 TS8 2"-1QD-HN-655091-B1 2 5.5 1.4 75% 740 7 7
each)
21 TS36 42"-1QD-LN-642062-A1 1 6.4 0.9 86% 150 285 2 2 2# straight pipe (1ft each)

Regards,

_________________________________________________________________

Osahon Orhue | Mobil Producing Nigeria | OTS – DW Asset Engr’g Support

DL: 09091022340 | Cell: 08172074988 | Email: osahon.orhue@exxonmobil.com

From: Orhue, Osahon


Sent: Monday, September 18, 2017 9:38 AM
To: 'Ezikpe Chima' <chima.ezikpe@engineeringautomation-ng.com>
Cc: emmanuel.okon@engineeringautomation-ng.com; Olumide, Iyiola <iyiola.awosope@exxonmobil.com>; Moninuola, Babatunde O <babatunde.o.moninuola@exxonmobil.com>
Subject: RE: High Pressure Repair Evaluation request

Chima,

Thanks on the prompt response. Please provide additional clarification on the design proposal presented by Pipewrap on one of the lines below:

Pristine pipe (system design pressure) – 5805psi

Composite only – 4238psi

Rehabbed pipe – 5859psi

Is EATech / Pipewrap repairing for 4238psi or 5859psi as highlighted in red above?

Appreciate your timely response.

3 of 6 13-Oct-17, 3:06 PM
Webmail - Read Message http://mbox.engineeringautomation-ng.com/readmessage.php?msg=892...

Regards,

_________________________________________________________________

Osahon Orhue | Mobil Producing Nigeria | OTS – DW Asset Engr’g Support

DL: 09091022340 | Cell: 08172074988 | Email: osahon.orhue@exxonmobil.com

From: Ezikpe Chima [mailto:chima.ezikpe@engineeringautomation-ng.com]


Sent: Monday, September 18, 2017 9:17 AM
To: Orhue, Osahon <osahon.orhue@exxonmobil.com>
Cc: emmanuel.okon@engineeringautomation-ng.com
Subject: RE: High Pressure Repair Evaluation request

FYI.

Please note that defect length is not captured.

Regard

Ezikpe, Chima Raphael

Project Group 1 Manager


Engineering Automation Technology LTD
Ikot Idoma
Eket
Akwa Ibom State
+2348028905615

"This email, any attachment and response string are confidential and may be legally privileged. If you are not the intended recipient,kindly notify the sender by return m ail and delete this
message and any attachment immediately. Please do not copy, forward or use the message or attachment except as permitted by the author"

From: Orhue, Osahon [mailto:osahon.orhue@exxonmobil.com]


Sent: Tuesday, September 12, 2017 6:25 PM
To: 'chima.ezikpe@engineeringautomation-ng.com'
Cc: 'emmanuel.okon@engineeringautomation-ng.com'
Subject: High Pressure Repair Evaluation request

Chima,

Find below list of 16 lines with design pressures ranging from 2220 – 5805psig with varying percentage wall loss.

Please engage your design partners (Pipewrap) for design evaluation of the maximum wrap repair pressures these lines could be repaired to in the light of the remaining wa ll.

Please note that these lines are not leaking.

Nominal Min Wall


Scope SIZE % Wall
S/N Line # WT Thickness Design Pressure (psig)
# (IN) Loss
(mm) (mm)

1 TS3 2"-1KD-ZN-651126-G5 2 11.1 3.1 72% 5805

2 TS14 2"-1KD-ZN-651128-G5 2 11.1 3.5 68% 5805

3 TS16 2"-1KD-ZN-651265-G5 2 11.1 5.5 50% 5805

4 TS17 2"-1KD-DC-661052-E1 2 8.7 3.2 63% 2220

5 TS18 3"-1KD-DC-661058-E1 3 11.1 2.3 79% 2220

6 TS19 2"-1KD-DC-661061-E1 2 8.7 1.6 82% 2220

7 TS20 2"-1KD-DC-661062-E1 2 8.7 2.7 69% 2220

8 TS22 2"-1KD-TR-651010-F5 2 11.1 3.7 67% 3480

9 TS26 2"-1KD-DC-661134-E1 2 8.7 3.3 62% 2220

10 TS28 2"-1KD-DC-651213-F5 2 11.1 3.2 71% 3480

4 of 6 13-Oct-17, 3:06 PM
Webmail - Read Message http://mbox.engineeringautomation-ng.com/readmessage.php?msg=892...

11 TS29 2"-1KD-DC-651045-F5 2 11.1 2.9 74% 3480

12 US3 2"-1KD-ZN-651264-G5 2 11.1 3.8 66% 5805

13 US5 3"-1KD-GX-651096-F5 2 11.1 3.9 65% 3480

14 US6 2"-1KD-GX-651099-G5 2 11.1 6.8 39% 5805

15 US7 3"-1KD-GX-651118-F5 3 15.2 3.1 80% 3480

16 US8 2"-1KD-GX-651120-G5 2 11.1 2.9 74% 5805

Note: Scanned QVF will be sent in a separate mail.

Regards,

_________________________________________________________________

Osahon Orhue | Mobil Producing Nigeria | OTS – DW Asset Engr’g Support

DL: 09091022340 | Cell: 08172074988 | Email: osahon.orhue@exxonmobil.com

Confidentiality and Commercial Terms and Conditions Notice:

Privileged/Confidential information may be contained in this message and is intended only for the use of the addressee. Please advise immediately if you or your employer do not consent to Internet e-mail for messages of this kind. If you are not the addressee, or person responsible for delivering to the person
addressed, you may not copy or deliver this to anyone else. If you receive this message by mistake, please notify the sender immediately by return e-mail. All commercial transactions, offers and acceptances are exclusively subject/limited to and conditioned upon our terms posted at www.milliken.com/terms, and we
object to and reject any of your additional/different terms and conditions unless we expressly agree to them in a signed writing.
Thank you.

5 of 6 13-Oct-17, 3:06 PM
Webmail - Read Message http://mbox.engineeringautomation-ng.com/readmessage.php?msg=892...

Reply Reply All Forward Forward as Attachment Delete Print View Source Download Show Headers Mark as Unread Put in Folder

Previous Next

6 of 6 13-Oct-17, 3:06 PM

S-ar putea să vă placă și