Documente Academic
Documente Profesional
Documente Cultură
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0 Plan
0 0 0
Project VILLA REINFORCED CONCRETE COUNCIL
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0 Plan
0 0 0
Project VILLA
DETAILED CALCULATIONS
Veff/Vt 1.1500 (enhancement factor) link leg area 50.3
Hole deduction ? NO
CRITICAL PERIMETERS ENCLOSED AREAS
Per No a Internal deduct Final m Per No Internal
1 360 5080 0 5080 1 1.550
2 540 6520 0 6520 2 2.594
3 720 7960 0 7960 3 3.898
4 900 9400 0 9400 4 5.460
5 1080 10840 0 10840 5 7.282
6 1260 12280 0 12280 6 9.362
7 1440 13720 0 13720 7 11.702
8 1620 15160 0 15160 8 14.302
Hole face 1100 11000 0 11000 Hole face 7.500
Col face 0 2200 0 2200 Col face 0.240
LINK PERIMETERS
Per No a Internal deduct Final m No Spacing
1 120 3160 0 3160 11 350
2 300 4600 0 4600 15 350
3 480 6040 0 6040 19 355
4 660 7480 0 7480 23 355
5 840 8920 0 8920 27 355
6 1020 10360 0 10360 31 355
7 1200 11800 0 11800 35 355
8 1380 13240 0 13240 39 355
9 1560 14680 0 14680 43 355
Project VILLA
DETAILED CALCULATIONS
Veff/Vt 1.4000 (enhancement factor) link leg area 50.3
Hole deduction ? NO
CRITICAL PERIMETERS ENCLOSED AREAS
Per No a Internal Choose m deduct Final m Per No Edge D
1 334.5 4076 2238 0 2238 1 0.625
2 501.75 5414 2907 0 2907 2 1.055
3 669 6752 3576 0 3576 3 1.597
4 836.25 8090 4245 0 4245 4 2.251
5 1003.5 9428 4914 0 4914 5 3.017
6 1170.75 10766 5583 0 5583 6 3.895
7 1338 12104 6252 0 6252 7 4.885
8 1505.25 13442 6921 0 6921 8 5.986
Hole face 1250 11400 5900 0 5900 Hole face 4.350
Col face 0 900 0 900 Col face 0.100
LINK PERIMETERS
Per No a Internal Choose m deduct Final m No Spacing
1 111.5 2292 1346 0 1346 7 265
2 278.75 3630 2015 0 2015 9 285
3 446 4968 2684 0 2684 11 295
4 613.25 6306 3353 0 3353 13 300
5 780.5 7644 4022 0 4022 15 305
6 947.75 8982 4691 0 4691 17 310
7 1115 10320 5360 0 5360 19 315
8 1282.25 11658 6029 0 6029 21 315
9 1449.5 12996 6698 0 6698 23 315
Project VILLA
DETAILED CALCULATIONS
Veff/Vt 1.2500 (enhancement factor) link leg area 50.3
Hole deduction ? NO
CRITICAL PERIMETERS
Per No a Internal Edge C Edge D Corner Choose m deduct Final m
1 306 4448 3024 2424 1612 1612 0 1612
2 459 5672 3636 3036 1918 1918 0 1918
3 612 6896 4248 3648 2224 2224 0 2224
4 765 8120 4860 4260 2530 2530 0 2530
5 918 9344 5472 4872 2836 2836 0 2836
6 1071 10568 6084 5484 3142 3142 0 3142
7 1224 11792 6696 6096 3448 3448 0 3448
8 1377 13016 7308 6708 3754 3754 0 3754
Hole face 1100 10800 6200 5600 3200 3200 0 3200
Col face 0 1000 1000 0 1000
LINK PERIMETERS
Per No a Internal Edge C Edge D Corner Choose m deduct Final m No Spacing
1 102 2816 2208 1608 1204 1204 0 1204 25 50
2 255 4040 2820 2220 1510 1510 0 1510 36 40
3 408 5264 3432 2832 1816 1816 0 1816 12 165
4 561 6488 4044 3444 2122 2122 0 2122 17 130
5 714 7712 4656 4056 2428 2428 0 2428 9 300
6 867 8936 5268 4668 2734 2734 0 2734 10 300
7 1020 10160 5880 5280 3040 3040 0 3040 11 300
8 1173 11384 6492 5892 3346 3346 0 3346 12 300
9 1326 12608 7104 6504 3652 3652 0 3652 13 300
Project VILLA
DETAILED CALCULATIONS
Veff/Vt 1.4000 (enhancement factor) link leg area 50.3
Hole deduction ? YES
CRITICAL PERIMETERS ENCLOSED AREAS
Per No a Internal Corner deduct Final m Per No Internal Corner
1 307.5 3860 3245 158 3087 1 0.929 0.430
2 461.25 5090 4167.5 144 4023 2 1.617 0.656
3 615 6320 5090 130 4960 3 2.494 0.929
4 768.75 7550 6012.5 116 5896 4 3.560 1.249
5 922.5 8780 6935 103 6833 5 4.816 1.617
6 1076.25 10010 7857.5 89 7769 6 6.260 2.032
7 1230 11240 8780 75 8705 7 7.894 2.494
8 1383.75 12470 9702.5 61 9642 8 9.716 3.003
Hole face 25 1600 1550 109 1441 Hole face 0.158 0.138
Col face 0 1400 0 1400 Col face 0.120
LINK PERIMETERS
Per No a Internal Corner deduct Final m No Spacing
1 102.5 2220 1315 157 1158 6 285
2 256.25 3450 2237.5 163 2074 9 295
3 410 4680 3160 149 3011 12 300
4 563.75 5910 4082.5 135 3947 15 300
5 717.5 7140 5005 121 4884 18 305
6 871.25 8370 5927.5 107 5820 21 305
7 1025 9600 6850 93 6757 24 305
8 1178.75 10830 7772.5 79 7693 28 295
9 1332.5 12060 8695 65 8630 31 295
Disclaimer
All advice or information from the British Cement Association and/or Reinforced Concrete
Council is intended for those who will evaluate the significance and limitations of its
contents and take responsibility for its use and application. No liability (including that for
negligence) for any loss resulting from such advice or information is accepted by the BCA,
RCC or their subcontractors, suppliers or advisors. Users should note that all BCA software
and publications are subject to revision from time to time and should therefore ensure that
they are in possession of the latest version.
mpanying publication
from British Cement
Size (kB)
402
421
421
404
407
310
309