ABB has been manufacturing motors for over 100 years. Our products are
designed to be reliable, efficient and cost effective, and we can supply motors
for practically any application. A full range of services is available through our
worldwide service organization, with the latest eBusiness systems providing
round-the-clock access, easy ordering and fast delivery.
M3000 motors
Customized to fit the individual user’s needs, the motors in ABB’s M3000 range
are designed to meet the tough demands of modern industry.With its M3000
range ABB offers a full range of motors that comply with eff1 - the EU’s highest
efficiency class – which translates into cost savings and better environmental
compatibility. Reliable, high quality products that are designed to last, ABB’s
M3000 motors offer years of trouble-free operation, even in critical environ-
ments.
IndustrialIT
As a key element of its business strategy, ABB has committed to a broad
IT
program of product development and positioning under the Industrial umbrella.
This initiative is geared towards increasing standardization of ABB products as
the ‘building blocks’ of larger solutions, while incorporating functionality that will
allow multiple products to interact seamlessly as components of real-time
automation and information systems.
Motors and generators represent one of the fundamental building blocks in the
IT
Industrial architecture.
ABB (www.abb.com) is a leader in power and automation technologies that enable utility and
industry customers to improve performance while lowering environmental impact. The ABB Group
ot companies operates in more than 100 countries and employs about 146,000 people.
Contents Page
Permanent Magnet motors for Variable Speed
Application ......................................................................... 4
Mechanical design ............................................................ 5
Stator
Drain holes
Terminal box
Bearings
Bearing seals
Bearing life
Lubrication
Pulley diameter
Permissible loadings on the shaft end
Operation ........................................................................... 9
Rating plates ..................................................................... 11
Ordering information ........................................................ 11
Data tables ........................................................................ 12
Variant codes .................................................................... 16
Dimension drawings ........................................................ 20
Permanent magnet motors in brief ................................. 29
DriveIT Low Voltage Motors’ total product offer ............. 30
Visit to our web site .......................................................... 31
Stator
The motor frame, including feet, bearing housing and
terminal box is made of cast iron. Integrally cast feet
allow a very rigid mounting and minimal vibration.
Drain holes
Motors that will be operated in very humid or wet Motor sizes 280 to 400 are fitted with drain holes and
environments, and especially under intermittent duty, closable plugs. The plugs are open on delivery. When
should be provided with drain holes. The appropriate IM mounting the motor, ensure that the drain holes face
designation, such as IM 3031, is specified, on the basis downwards.
of the method of motor mounting.
closed
open
open
Opening c e f g d
C (FL 21) 62 193 62 193 M8
D (FL 33) 100 300 80 292 M10
E (FL 40) 115 370 100 360 M12
Terminal box 122/142 Terminal box 162 with adapting flange MPMM-ZL 1:
E-opening
Terminal box
The motors are normally fitted with single-row deep Standard design
groove ball bearings as listed in the table below. Motor Deep groove ball berings
size D-end N-end
Bearing seals
Motors have, as standard, axial seals at both ends. The
size and type of suitable seals are in accordance with
the table below:
Bearing life
The nominal life L10 of a bearing is defined according to The calculated bearing life L10 for power transmission by
ISO as the number of operating hours achieved or means of a coupling (horizontal machine):
exceeded by 90% of identical bearings in a large test
Motor sizes 280 to 400 ≥ 200.000 hours.
series under certain specified conditions. 50% of the
bearings achieve at least five times this figure.
Lubrication
On delivery, the motors are lubricated with a type of Permanent magnet motors, sizes 280 to 400, have
grease intended for use in dry or humid environments, grease valve lubrication for lubrication in service. The
at normal ambient temperature. lubrication intervals and grease quantity are stated in the
maintenance instruction which comes with the motor.
280 SM_ 140 9200 7800 7300 6200 355 SM_ 210 15200 12500 12000 985
315 SM_ 170 11300 9400 9000 7500 355 ML_ 210 15200 12800 12000 10100
315 ML_ 170 11300 9400 9000 7500 400 LK_ 210 15000 13000 11700 10100
The output torque of the permanent magnet motors is The loadability curve in figure 1 below is a guide only, for
constant, but the cooling capabilities may limit the exact values please contact ABB.These guidelines show
actual loadability of the self cooled versions (IC411). the maximum continuous load torque of a motor as a
Motors are also available with external cooling fans function of frequency (speed).
(IC416) and liquid cooling (M2LJ) where motors can
deliver constant torque (CT) all the way to zero speed.
Above the nominal frequency, up to 1,2 times the
nominal speed (Nn), the motors are designed to
produce the constant power (CP).
Loadability
120 %
100 %
80 %
Torque
IC411
60 %
IC416
40 %
20 %
0%
0.00 0.50 1.00 1.50
Speed / nominal
2. Lubrication
The effectiveness of the motor lubrication should be When the bearing temperature is low and when the motor
checked by measuring the bearing temperature under is running slowly, lubricants containing EP admixtures
normal operating conditions. If the measured tempera- can be used.
ture is higher than +80°C, the relubrication intervals
specified in ABB’s Machine Instructions for permanent 4. Insulation protection
magnet synchronous motors must be shortened; i.e. If the frequency converter has IGBT power components
the relubrication interval should be halved for every with very rapid switching, practically all cables between
15 K increase in bearing temperature. If this is not the converter and the motor will be long. In that case,
possible, please contact ABB. steep voltage pulses and reflections within the cables
increase voltage stresses in the winding of the motor and
therefore, the precautions described in figure 2 on page 10
must be taken to avoid risks of insulation damages.
Figure 2. Selection rules for insulation and filtering in variable speed drives.
Motor nominal power or frame size
PN < 100 kW PN ≥ 100 kW or ≥ IEC 315 PN ≥ 350 kW or ≥ IEC 400
dU/dt filter
Series reactor. dU/dt filters decrease the changing rate of the phase and main voltages and thus reduce voltage stresses in
the windings. dU/dt filters also decrease so called common mode currents and bearing currents.
Common mode and light common mode filters
Common mode filters are made of toroidal cores installed around motor cables. These filters reduce so called common mode
currents in VSD applications and thus decrease the risk of bearing currents. Common mode filters do not significantly affect
the phase or main voltages on the motor terminals. For the exact type of the core, please contact ABB.
Common Mode Filter = 3 toroidal cores per each 3-phase motor cable
Light Common Mode Filter = 1 toroidal core per each 3-phase motor cable
Prod.code 3GBJ316410-AXA
INSULATED BEARING AT N-END
6319/C3 6316/C4VLO24 1030 kg
IEC 60034-1
Ordering information
Sample order
When placing an order, the motor type, size and product
code must be specified. The product code of the motor
is composed in accordance with the following example.
Motor size
A B C D, E, F, G A Motor type
B Motor size
M2BJ 280 SMB 3GBJ 316 222 - A D A 003 C Product code
D Mounting arrangement code
1- 4 5-6 7 8 9 10 11 12 13 14 E Voltage and frequency code
F Generation code
G Variant codes
Explanation of the product code:
Positions 1 to 4 Position 11
3GBJ = Totally enclosed fan cooled permanent magnet - (dash)
motor with cast iron frame
Position 12
Positions 5 and 6
Mounting arrangement
IEC-frame
A = Foot-mounted, top-mounted terminal box
28 = 280
31 = 315
35 = 355 Position 13
40 = 400 Voltage and frequency code
Network voltage 400 V/690 V
Position 7
Position 14
Speed (Pole pairs)
Generation code
6 = 12 poles
A, B, C...
The product code must be, if needed, followed by variant
Position 8 to 9
codes.
Serial number
Position 10 Motors, frame size 280, include variant codes 405 and
Base speed 445 as standard.
2 = 220 r/min
3 = 300 r/min Motors, frame sizes 315 to 400, include variant codes 405,
4 = 430 r/min 445 and 701 as standard.
6 = 600 r/min
25 M2BJ 315SMB 3GBJ 316 222-ADA 90.4 0.95 52 1085 2.0 3.9 820
35 M2BJ 315MLA 3GBJ 316 412-ADA 91.5 0.94 68 1519 2.1 5.8 1000
53 M2BJ 355SMA 3GBJ 356 212-ADA 92.8 0.96 95 2301 2.5 14.0 1570
88 M2BJ 355MLC 3GBJ 356 432-ADA 92.7 0.98 158 3820 2.1 19.7 1940
134 M2BJ 400LKC 3GBJ 406 532-ADA 94.6 0.97 240 5816 2.1 40.7 2930
Cooling designation : IC 416 (with external cooling fan, variant code 183)
Loadability: Suitable for CT : 0 - nn , CP: nn - 1.2 x nn3)
1)
25 M2BJ 280SMB 3GBJ 286 222-ADA183 81.7 0.93 50 1085 1.3 2.2 640
40 M2BJ 315SMB 3GBJ 316 222-ADA183 81.9 0.91 80 1736 1.2 3.9 840
55 M2BJ 315MLA 3GBJ 316 412-ADA183 85.7 0.93 105 2387 1.2 5.8 1030
80 M2BJ 355SMA 3GBJ 356 212-ADA183 89.3 0.96 142 3472 1.6 14.0 1590
132 M2BJ 355MLC 3GBJ 356 432-ADA183 89.4 0.96 237 5730 1.3 19.7 1960
200 M2BJ 400LKC 3GBJ 406 532-ADA183 92.3 0.95 360 8681 1.4 40.7 2960
2)
40 M2LJ 315SMB 3GLJ 316 222-ADA 85.8 0.91 80 1736 1.2 3.9
2)
55 M2LJ 315MLA 3GLJ 316 412-ADA 88.7 0.93 105 2387 1.2 5.8
2)
80 M2LJ 355SMA 3GLJ 356 212-ADA 91.6 0.96 142 3472 1.6 14.0
2)
132 M2LJ 355MLC 3GLJ 356 432-ADA 90.4 0.96 237 5730 1.3 19.7
2)
200 M2LJ 400LKC 3GLJ 406 532-ADA 93.2 0.95 360 8681 1.4 40.7
1)
In frame size 280 includes variant codes 405 and 445 as standard.
2)
On request Motors include variant codes 405, 445 and 701
3)
CT = Constant torque
as standard, please see the variant codes
CP = Constant power
nn = Nominal speed on pages 16-19.
4)
Other voltages on request
38 M2BJ 315SMB 3GBJ 316 223-ADA 92.1 0.94 73 1210 1.8 3.9 820
55 M2BJ 315MLA 3GBJ 316 413-ADA 93.0 0.95 104 1751 1.8 5.8 1000
78 M2BJ 355SMA 3GBJ 356 213-ADA 94.1 0.97 136 2483 2.2 14.0 1570
132 M2BJ 355MLC 3GBJ 356 433-ADA 94.1 0.96 235 4202 1.9 19.7 1940
200 M2BJ 400LKC 3GBJ 406 533-ADA 95.5 0.97 346 6366 1.9 40.7 2930
Cooling designation : IC 416 (with external cooling fan, variant code 183)
Loadability: Suitable for CT : 0 - nn , CP: nn - 1.2 x nn3)
1)
35 M2BJ 280SMB 3GBJ 286 223-ADA183 85.0 0.92 68 1114 1.3 2.2 640
55 M2BJ 315SMB 3GBJ 316 223-ADA183 86.3 0.91 106 1751 1.2 3.9 840
80 M2BJ 315MLA 3GBJ 316 413-ADA183 88.6 0.91 151 2546 1.2 5.8 1030
110 M2BJ 355SMA 3GBJ 356 213-ADA183 91.5 0.97 191 3501 1.6 14.0 1590
185 M2BJ 355MLC 3GBJ 356 433-ADA183 91.5 0.95 329 5889 1.3 19.7 1960
280 M2BJ 400LKC 3GBJ 406 533-ADA183 93.9 0.95 485 8913 1.4 40.7 2960
2)
55 M2LJ 315SMB 3GLJ 316 223-ADA 89.4 0.91 106 1751 1.2 3.9
2)
80 M2LJ 315MLA 3GLJ 316 413-ADA 90.8 0.91 151 2546 1.2 5.8
2)
110 M2LJ 355SMA 3GLJ 356 213-ADA 93.2 0.97 191 3501 1.6 14.0
2)
185 M2LJ 355MLC 3GLJ 356 433-ADA 92.9 0.95 329 5889 1.3 19.7
2)
280 M2LJ 400LKC 3GLJ 406 533-ADA 94.6 0.95 485 8913 1.4 40.7
1)
In frame size 280 includes variant codes 405 and 445 as standard.
2)
On request Motors include variant codes 405, 445 and 701
3)
CT = Constant torque
CP = Constant power
as standard, please see the variant codes
nn = Nominal speed on pages 16-19.
4)
Other voltages on request
56 M2BJ 315SMB 3GBJ 316 224-ADA 93.5 0.94 104 1244 1.7 3.9 820
82 M2BJ 315MLA 3GBJ 316 414-ADA 94.1 0.94 151 1821 1.7 5.8 1000
115 M2BJ 355SMA 3GBJ 356 214-ADA 95.0 0.96 198 2554 2.2 14.0 1570
192 M2BJ 355MLC 3GBJ 356 434-ADA 95.0 0.97 333 4264 1.8 19.7 1940
308 M2BJ 400LKC 3GBJ 406 534-ADA 96.2 0.95 533 6840 1.8 40.7 2930
Cooling designation : IC 416 (with external cooling fan, variant code 183)
Loadability: Suitable for CT : 0 - nn , CP: nn - 1.2 x nn3)
1)
50 M2BJ 280SMB 3GBJ 286 224-ADA183 88.5 0.92 95 1110 1.2 2.2 640
75 M2BJ 315SMB 3GBJ 316 224-ADA183 89.7 0.92 139 1666 1.3 3.9 840
110 M2BJ 315MLA 3GBJ 316 414-ADA183 91.4 0.92 203 2443 1.3 5.8 1030
150 M2BJ 355SMA 3GBJ 356 214-ADA183 93.5 0.96 257 3331 1.7 14.0 1590
250 M2BJ 355MLC 3GBJ 356 434-ADA183 93.4 0.96 432 5552 1.3 19.7 1960
400 M2BJ 400LKC 3GBJ 406 534-ADA183 95.4 0.94 693 8883 1.4 40.7 2960
Cooling designation : Water cooled
Loadability: Suitable for CT : 0 - nn , CP: nn - 1.2 x nn3)
1) 2)
50 M2LJ 280SMB 3GLJ 286 224-ADA 90.9 0.92 95 1110 1.2 2.2
2)
75 M2LJ 315SMB 3GLJ 316 224-ADA 92.1 0.92 139 1666 1.3 3.9
2)
110 M2LJ 315MLA 3GLJ 316 414-ADA 93.1 0.92 203 2443 1.3 5.8
2)
150 M2LJ 355SMA 3GLJ 356 214-ADA 94.8 0.96 257 3331 1.7 14.0
2)
250 M2LJ 355MLC 3GLJ 356 434-ADA 94.4 0.96 432 5552 1.3 19.7
2)
400 M2LJ 400LKC 3GLJ 406 534-ADA 95.9 0.94 693 8883 1.4 40.7
1)
In frame size 280 includes variant codes 405 and 445 as standard.
2)
On request
3)
CT = Constant torque Motors include variant codes 405, 445 and 701
CP = Constant power as standard, please see the variant codes
nn = Nominal speed
4)
Other voltages on request
on pages 16-19.
88 M2BJ 315SMB 3GBJ 316 226-ADA 94.6 0.92 164 1401 1.5 3.9 820
120 M2BJ 315MLA 3GBJ 316 416-ADA 95.2 0.91 219 1910 1.7 5.8 1000
165 M2BJ 355SMA 3GBJ 356 216-ADA 95.6 0.96 280 2626 2.0 14 1570
314 M2BJ 355MLC 3GBJ 356 436-ADA 95.8 0.90 565 4997 1.8 19.7 1940
413 M2BJ 400LKC 3GBJ 406 536-ADA 96.7 0.96 698 6573 1.8 40.7 2930
Cooling designation : IC 416 (with external cooling fan, variant code 183)
Loadability: Suitable for CT : 0 - nn , CP: nn - 1.2 x nn3)
70 M2BJ 280SMB 3GBJ 286 226-ADA183 91.4 0.91 129 1114 1.2 2.2 640
110 M2BJ 315SMB 3GBJ 316 226-ADA183 92.1 0.90 204 1751 1.2 3.9 840
150 M2BJ 315MLA 3GBJ 316 416-ADA183 93.5 0.90 273 2387 1.4 5.8 1030
200 M2BJ 355SMA 3GBJ 356 216-ADA183 94.6 0.96 339 3183 1.7 14 1590
380 M2BJ 355MLC 3GBJ 356 436-ADA183 95.2 0.91 683 6048 1.5 19.7 1960
500 M2BJ 400LKC 3GBJ 406 536-ADA183 96.2 0.96 884 7958 1.5 40.7 2960
Cooling designation : Water cooled
Loadability: SuitableCT : 0 - nn , CP: nn - 1.2 x nn3)
2)
70 M2LJ 280SMB 3GLJ 286 226-ADA 93.2 0.91 129 1114 1.2 2.2
2)
110 M2LJ 315SMB 3GLJ 316 226-ADA 93.8 0.90 204 1751 1.2 3.9
2)
150 M2LJ 315MLA 3GLJ 316 416-ADA 94.8 0.90 273 2387 1.4 5.8
2)
200 M2LJ 355SMA 3GLJ 356 216-ADA 95.6 0.96 339 3183 1.7 14
2)
380 M2LJ 355MLC 3GLJ 356 436-ADA 95.7 0.91 683 6048 1.5 19.7
2)
500 M2LJ 400LKC 3GLJ 406 536-ADA 96.6 0.96 884 7958 1.5 40.7
1)
In frame size 280 includes variant codes 405 and 445 as standard.
2)
On request
3)
CT = Constant torque Motors include variant codes 405, 445 and 701
CP = Constant power as standard, please see the variant codes
nn = Nominal speed
4)
on pages 16-19.
Other voltages on request
Balancing
424 Full key balancing. P P P
Cooling system
044 Unidirectional fan, clockwise seen from D-end. R R R
045 Unidirectional fan, counter clockwise seen from D-end. R R R
054 Special fan for noise reduction. R R R
068 Metal fan.
Mandatory for ambient temperatures ≥ 60°C. R R R
490 Plastic fan with metal hub. R R R
183 Separate motor cooling (fan axial, N-end). P P P
422 Separate motor cooling (fan top or side, N-end). P P P
791 Stainless steel fan cover. P P P
Coupling
035 Assembly of customer supplied coupling-half (finish bored and balanced). R R R
Dimension drawing
141 Binding dimension drawing. M M M
Drain holes
065 Plugged existing drain holes. M M M
066 Modified drain hole position (for specified IM xxxx). M M M
076 Draining holes with plugs. S S S
1)
Certain variant codes cannot be used simultaneously. S = Included as standard P = New manufacture only.
M = On modification of a stocked motor, R = On request.
or on new manufacture, NA = Not applicable
the number per order may be limited.
Earthing bolt
Heating elements
450 Heating element, 100-120 V. M M M
451 Heating element, 200-240 V. M M M
Insulation system
Mounting arrangements
009 IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3). R R R
Noise reduction
Painting
114 Special paint colour, standard grade. M M M
115 Offshore zink primer painting. R R R
179 Special paint specification. R R R
Protection
072 Radial seal at D-end. M M M
073 Sealed against oil at D-end. R R R
401 Protective roof, horizontal motor. P P P
403 Degree of protection IP 56. P P M
783 Labyrinth sealing at D-end. M M M
1)
Certain variant codes cannot be used simultaneously. S = Included as standard P = New manufacture only.
M = On modification of a stocked motor, R = On request.
or on new manufacture, NA = Not applicable
the number per order may be limited.
121 Bimetal detectors, break type (NCC), (3 in series), 130°C, in stator winding. M M M
122 Bimetal detectors, break type (NCC), (3 in series), 150°C, in stator winding. M M M
123 Bimetal detectors, break type (NCC), (3 in series), 170°C, in stator winding. M M M
125 Bimetal detectors, break type (NCC), (2x3 in series), 150°C, in stator winding. M M M
127 Bimetal detectors, break type (NCC), (3 in series, 130°C and
3 in series, 150°C), in stator winding. M M M
435 PTC - thermistors (3 in series), 130°C, in stator winding.
Two speed motors, only for new manufacture. M M M
436 PTC - thermistors (3 in series), 150°C, in stator winding.
Two speed motors, only for new manufacture. S S S
437 PTC - thermistors (3 in series), 170°C, in stator winding.
Two speed motors, only for new manufacture. M M M
439 PTC - thermistors (2x3 in series), 150°C, in stator winding.
Two speed motors, only for new manufacture. M M M
441 PTC - thermistors (3 in series, 130°C and 3 in series,
150°C, in stator winding. Two speed motors, only for new manufacture. M M M
442 PTC - thermistors (3 in series, 150°C and 3 in series, 170°C, in stator winding.
Two speed motors, only for new manufacture. M M M
445 PT100 (1 per phase) in stator winding. S S S
446 PT100 (2 per phase) in stator winding. M M M
Terminal box
015 Motor supplied in D-connection. M M M
017 Motor supplied in Y-connection. M M M
019 Larger than standard terminal box. R R R
021 Terminal box LHS (seen from D-end). R R R
180 Terminal box RHS (seen from D-end). R R R
137 Extended cable connection, low terminal box, "Flying leads". P P R
230 Standard cable glands. S S S
400 4 x 90 degr turnable terminal box. P P M
402 Terminal box adapted for Al cables. S S M
418 Separate terminal box for temperature detectors. P P P
1)
Certain variant codes cannot be used simultaneously. S = Included as standard P = New manufacture only.
M = On modification of a stocked motor, R = On request.
or on new manufacture,
the number per order may be limited.
Testing
Cooling system
183 Separate motor cooling (fan axial, N-end). P P P
422 Separate motor cooling (fan top or side, N-end). P P P
Mounting of tacho; tacho not included
182 Pulse sensor mounted as specified (Leine & Linde equivalent, hollow-shaft type). P P P
470 Prepared for hollow shaft pulse tacho (Leine&Linde equivalent). P P P
479 Mounting of other types of tachos with shaft extension. P P P
Mounting of tacho; tacho included
062 Tachogenerator. P P P
471 512 hollow shaft pulse tacho (Leine&Linde equivalent) mounted. P P P
472 1024 hollow shaft pulse tacho (Leine&Linde equivalent) mounted. P P P
473 2048 hollow shaft pulse tacho (Leine&Linde equivalent) mounted. P P P
Separate motor cooling & tacho; tacho not included
474 Separate motor cooling and prepared for hollow shaft
pulse tacho (Leine&Linde equivalent). P P P
478 Separate motor cooling (fan top, N-end) and prepared for hollow shaft
pulse tacho (Leine&Linde equivalent. P P P
Separate motor cooling & tacho; tacho included
428 Separate motor cooling (fan top, N-end) and Leine &
Linde, type 510 006361, pulse tacho. P P P
429 Separate motor cooling (fan top, N-end) and Leine &
Linde, type 861007455, hollow shaft pulse tacho. P P P
475 Separate motor cooling (fan axial, N-end) and 512
hollow shaft pulse tacho (L&L equivalent). P P P
476 Separate motor cooling (fan axial, N-end) and 1024
hollow shaft pulse tacho (L&L equivalent). P P P
477 Separate motor cooling (fan axial, N-end) and 2048
hollow shaft pulse tacho (L&L equivalent). P P P
1)
Certain variant codes cannot be used simultaneously. S = Included as standard P = New manufacture only.
M = On modification of a stocked motor, R = On request.
or on new manufacture,
the number per order may be limited.
2)
280 SM_ 457 85 530 572 368 419 146 506 190 400 349 75 65 M20 M20 140 140 40 40
315 SM_ 508 100 590 645 406 457 163 556 216 465 414 80 75 M20 M20 170 140 40 40
315 ML_ 508 100 590 645 457 508 163 607 216 465 414 90 75 M24 M20 170 140 48 40
Motor F FA G GA GB GC GD GF H HA HC HD K L LC LD O
2)
size
280 SM_ 20 18 67.5 79.5 58 69 12 11 280 40 566 745 24 1088 1238 332 100
315 SM_ 22 20 71 85 67.5 79.5 14 12 315 50 638 840 30 1248 1397 381 115
315 ML_ 25 20 81 95 67.5 79.5 14 12 315 50 638 840 30 1299 1448 381 115
1)
Tolerances: Cooling distance.
2)
D,DA ISO m6 Second shaft end on request.
H ISO 0, - 1.0 Above table gives the main dimensions in mm.
For detailed drawings please contact us.
355 SM_ 610 120 700 740 500 560 161 722 254 512 452 100 90 M24 M24 210 170 48 48
355 ML_ 610 120 700 740 560 630 161 792 254 557 487 100 90 M24 M24 210 170 48 48
400 LK_ 686 140 820 824 710 800 170 967 280 558 468 100 90 M24 M24 210 170 48 48
Motor F FA G GA GB GC GD GF H HA HC HD K L LC LD O si
1)
size
355 SM_ 28 25 90 106 81 95 16 14 355 55 725 955 35 1466 1646 467 130
355 ML_ 28 25 90 106 81 95 16 14 355 55 725 955 35 1571 1751 467 130
400 LK_ 28 25 90 106 81 95 16 14 400 55 812 1040 35 1748 1928 502 150
1)
Tolerances: Cooling distance.
D,DA ISO m6
H ISO 0, - 1.0 Above table gives the main dimensions in mm.
For detailed drawings please contact us.
Motor A AA AB AC B B’ BA BB C D DB E
size
280 SM_ 457 85 530 572 368 419 134 506 190 75 M20 140
315 SM_ 508 100 590 645 406 457 163 556 216 80 M20 170
315 ML_ 508 100 590 645 457 508 163 607 216 90 M20 170
Motor F G GA GD H HA HC HD K L LC LD O
size
280 SM_ 20 67.5 79.5 12 280 40 566 745 24 1100 1370 332 25
315 SM_ 22 71 85 14 315 50 638 840 30 1225 1523 381 25
315 ML_ 25 81 95 14 315 50 638 840 30 1276 1574 381 25
Motor A AA AB AC B B’ BA BB C D DB E EG
size
355 SM_ 610 120 700 740 500 560 161 722 254 100 M24 210 48
355 ML_ 610 120 700 740 560 630 161 792 254 100 M24 210 48
400 LK_ 686 140 820 824 710 800 170 967 280 100 M24 210 48
Motor F G GA GD H HA HC HD K L LC LD O
size
355 SM_ 28 90 106 16 355 55 725 955 35 1488 1786 467 25
355 ML_ 28 90 106 16 355 55 725 955 35 1593 1891 467 25
Motor A AA AB AC B B’ BA BB C D DB E EG F
size
280SM_ 457 85 530 572 368 419 134 506 190 75 M20 140 40 20
315SM_ 508 100 590 645 406 457 163 556 216 80 M20 170 40 22
315ML_ 508 100 590 645 457 508 163 607 216 90 M24 170 48 25
Motor G GA GD H HA HC HD H1 K L L’ LD O O’
size
280SM_ 67.5 79.5 12 280 40 566 745 1250 24 1125 1317 332 130 25
315SM_ 71 85 14 315 50 638 840 1320 30 1210 1397 381 130 25
315ML_ 81 95 14 315 50 638 840 1320 30 1261 1448 381 130 25
Motor A AA AB AC B B’ BA BB C D DB E EG F
size
355 SM_ 610 120 700 740 500 560 161 722 254 100 M24 210 48 28
355 ML_ 610 120 700 740 560 630 161 792 254 100 M24 210 48 28
400 LK_ 686 140 820 824 710 800 170 967 280 100 M24 210 48 28
Motor G GA GD H HA HC HD H1 K L L’ LD O O’
size
355 SM_ 90 106 16 355 55 725 955 1500 35 1471 1701 467 130 25
355 ML_ 90 106 16 355 55 725 955 1500 35 1576 1806 467 130 25
400 LK_ 90 106 16 400 55 812 1040 1588 35 1745 2000 502 130 25
Motor A AA AB AC B B’ BA BB C D DB E EG
1)
size
280 SM_ 457 85 530 544 368 419 135 470 190 75 M20 140 40
315 SM_ 508 100 590 615 406 457 130 537 216 80 M20 170 40
315 ML_ 508 100 590 615 457 508 130 588 216 90 M24 170 48
Motor F G GA GD H HA HD K L LD X Y
1)
size
280 SM_ 20 67.5 79.5 12 280 40 745 24 932 332 390 300
315 SM_ 22 71 85 14 315 50 840 30 1042 381 440 350
Motor A AA AB AC B B’ BA BB C D DB E E’ EG
1) 2)
size
355 SM_ 610 120 700 700 500 560 161 667 254 100 M24 210 190 48
355 ML_ 610 120 700 700 560 630 161 772 254 100 M24 210 190 48
400 LK_ 686 140 820 790 710 800 195 937 280 100 M24 210 190 48
Motor F G GA GD H HA HD K L LD X Y Z
1) 2)
size
355 SM_ 28 90 106 16 355 55 955 35 1282 467 530 450 180
355 ML_ 28 90 106 16 355 55 955 35 1387 467 530 550 180
400 LK_ 28 90 106 16 400 55 1040 35 1564 502 600 600 180
1)
Tolerances:
D ISO m6 Above table gives the main dimensions in mm.
H ISO 0, -1.0 For detailed drawings please contact us.
2)
Note: Motor sizes 355 to 400 with a bearing fan.
Terminal box type Motor size A1 B1 H1 Terminal box type Motor size A1 B1 H1
122/2 280 455 280 177 162/1, 162/2 + 355 - 400 787 410 226
Adapter MPMM-ZL1
142/1, 142/2 315 - 355 536 349 197
Bearing end shields Material CI EN-GJL200/GG 20/GRS 200, except flange-mounted IEC 355-400
Spheroidal graphit GG40/GRP400
Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G
Paint thickness Two-pack epoxy paint, thickness ≥ 70 µm
SPM-nipples As standard
M2000 range
Motor type IEC frame size Output kW
M3000 range
Motor type IEC frame size Output kW
Aluminium motors 56 - 280 0.055 - 95 kW
Cast iron motors 71 - 400 0.25 - 710 kW
Steel motors 280 - 400 75 - 630 kW
Hazardous area motors 71 - 400 0.25 - 630 kW
Marine motors 56 - 400 0.06 - 630 kW
Open drip proof motors (IP 23) 250 - 400 75 - 800 kW
Brake motors 63 - 160 0.12 - 15 kW
Single-phase motors 56 - 100 0.07 - 2.2 kW
Permanent magnet motors 280 - 400 17 - 500 kW
Integral motors 71 - 100 0.37 - 2.2 kW
Wind turbine generators 280 - 400 > 1 MW
Special types/alternatives
– high speed motors, over 3000 r/min – smoke venting design
– motor adjusted with a holding brake – fan application motors
– motors for roller table drives – slip-ring motors
– water cooled motors – stator/rotor units
ABB
Electrical Machines
Marketing communications
P.O.Box 633
FIN-65101 Vaasa
tel. +358 (0) 10 22 11
fax +358 (0) 10 22 43575
www.abb.com/motors&drives
http://www.abb.com/motors&drives
http://online.abb.com/motors&drives