ABB has been manufacturing motors for over 100 years. Our products are
designed to be reliable, efficient and cost effective, and we can supply motors
for practically any application. A full range of services is available through our
worldwide service organization, with the latest eBusiness systems providing
round-the-clock access, easy ordering and fast delivery.

M3000 motors
Customized to fit the individual user’s needs, the motors in ABB’s M3000 range
are designed to meet the tough demands of modern industry.With its M3000
range ABB offers a full range of motors that comply with eff1 - the EU’s highest
efficiency class – which translates into cost savings and better environmental
compatibility. Reliable, high quality products that are designed to last, ABB’s
M3000 motors offer years of trouble-free operation, even in critical environ-
ments.

IndustrialIT
As a key element of its business strategy, ABB has committed to a broad
IT
program of product development and positioning under the Industrial umbrella.
This initiative is geared towards increasing standardization of ABB products as
the ‘building blocks’ of larger solutions, while incorporating functionality that will
allow multiple products to interact seamlessly as components of real-time
automation and information systems.
Motors and generators represent one of the fundamental building blocks in the
IT
Industrial architecture.

ABB (www.abb.com) is a leader in power and automation technologies that enable utility and
industry customers to improve performance while lowering environmental impact. The ABB Group
ot companies operates in more than 100 countries and employs about 146,000 people.

2 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


DriveIT Low Voltage Permanent Magnet Motors
with cast iron frame
Sizes 280 to 400

Contents Page
Permanent Magnet motors for Variable Speed
Application ......................................................................... 4
Mechanical design ............................................................ 5
Stator
Drain holes
Terminal box
Bearings
Bearing seals
Bearing life
Lubrication
Pulley diameter
Permissible loadings on the shaft end

Operation ........................................................................... 9
Rating plates ..................................................................... 11
Ordering information ........................................................ 11
Data tables ........................................................................ 12
Variant codes .................................................................... 16
Dimension drawings ........................................................ 20
Permanent magnet motors in brief ................................. 29
DriveIT Low Voltage Motors’ total product offer ............. 30
Visit to our web site .......................................................... 31

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 3


Permanent Magnet Motors for Variable
Speed Applications
Permanent magnet motors are based on the same
DriveIT low voltage permanent magnet motors are wellknown and reliable technology as all other ABB low
permanent magnet synchronous motors, designed to voltage motors. The greatest difference is the modern
drive low speed applications directly, without a gear box. rotor construction, where the squirrel cage or the
Ideal applications are paper machines, extruders, magnetisation windings have been replaced by highly
elevators etc. efficient permanent magnets. This means that the major
The motors are designed exclusively for frequency benefits of squirrel cage and synchronous motors have
converter supply. ABB's frequency converters from the been combined to one product, called M2BJ or, when
ACS 600 and ACS 800 series are available with perma- liquid cooled, M2LJ.
nent magnet motor software.
ABB's Permanent Magnet Motor together with an ABB
frequency converter makes up the ABB Direct Drive
(DriveIT ) system.

The ABB Direct Drive system offers valuable benefits.


· Better overall efficiency
· Better controllability and adjustability
· No pulse encoder needed even with paper
machine drives
· Less components, less maintenance
· Easier to install
· Less space requirements

Conventional drive system (a) compared to Direct Drive (b).

4 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


Mechanical design

Stator
The motor frame, including feet, bearing housing and
terminal box is made of cast iron. Integrally cast feet
allow a very rigid mounting and minimal vibration.

Drain holes
Motors that will be operated in very humid or wet Motor sizes 280 to 400 are fitted with drain holes and
environments, and especially under intermittent duty, closable plugs. The plugs are open on delivery. When
should be provided with drain holes. The appropriate IM mounting the motor, ensure that the drain holes face
designation, such as IM 3031, is specified, on the basis downwards.
of the method of motor mounting.

closed

open

open

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 5


Terminal box
The terminal box can be turned 2x180°, to allow cable To enable the supply of suitable terminations for the
entry from either side of the motor. motor, please state cable type, quantity and size when
ordering. Non-standard design of terminal boxes, e.g.
Degree of protection of standard terminal box is IP 55.
size, degree of protection, are available as options.
The terminal box is equipped with cable glands or cable
boxes as standard.

Co-ordination of terminal boxes and cable


entries
The terminal box is equipped with cable glands or cable EMC-cable connection is recommended; this is
boxes as standard according the table below. Other available as variant code 704. Please consult ABB's
types are available on request. manual 'Grounding and cabling of the drive systems'
(Code: 3AFY 61201998).

Ter- Max. connection Terminal


Motor minal Flange or Cable box Gland Cable cable area bolt
size box adapter or cable gland thread diameter mm2 size
280 122/2 3GZF 294 730-749 2x 3GZF 294 730-613 2x M63x1.5 2x Ø32-49 2x150 M12
315 142/1 3GZF 294 730-753 2x 3GZF 294 730-613 2x M63x1.5 2x Ø32-49 2x240 M12
355 SM_ 142/2 3GZF 294 730-753 2x 3GZF 294 730-613 2x M63x1.5 2x Ø32-49 2x240 M12
355 ML_ 162/1 MPMM-ZL1 LNPB 3328 2x Ø60-80 4x240 M12
400 LK_ 162/1 MPMM-ZL1 LNPB 3328 2x Ø60-80 4x240 M12

Opening c e f g d
C (FL 21) 62 193 62 193 M8
D (FL 33) 100 300 80 292 M10
E (FL 40) 115 370 100 360 M12

Terminal box 122/142 Terminal box 162 with adapting flange MPMM-ZL 1:

E-opening
Terminal box

Flange with D-openings


cable gland

6 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


Bearings Bearing types

The motors are normally fitted with single-row deep Standard design
groove ball bearings as listed in the table below. Motor Deep groove ball berings
size D-end N-end

280 6316/C3 6316/C3


315 6319/C3 6316M/C4VL024
355 6322/C3 6319M/C4VL024
400 6322/C3 6319M/C4VL024

Bearing seals
Motors have, as standard, axial seals at both ends. The
size and type of suitable seals are in accordance with
the table below:

Standard design Alternative design


Motor d1 d2 B1 b Axial seal Radial seal (DIN 3760)
size D-end N-end Variant code 072
280 80 100 13.5 10 VS 80 VS 80 80x100x10
315 95 120 13.5 12 VS 95 VS 80 95x120x12
355 110 140 15.5 12 VS 110 VS 95 110x140x121)
400 110 140 15.5 12 VS 110 VS 95 110x140x121)

Bearing life
The nominal life L10 of a bearing is defined according to The calculated bearing life L10 for power transmission by
ISO as the number of operating hours achieved or means of a coupling (horizontal machine):
exceeded by 90% of identical bearings in a large test
Motor sizes 280 to 400 ≥ 200.000 hours.
series under certain specified conditions. 50% of the
bearings achieve at least five times this figure.

Lubrication
On delivery, the motors are lubricated with a type of Permanent magnet motors, sizes 280 to 400, have
grease intended for use in dry or humid environments, grease valve lubrication for lubrication in service. The
at normal ambient temperature. lubrication intervals and grease quantity are stated in the
maintenance instruction which comes with the motor.

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 7


Pulley diameter
When the desired bearing life has been determined, the where:
minimum permissible pulley diameter can be calculated D = diameter of pulley, mm
using F R, as follows: P = power requirement, kW
n = motor speed, r/min
1.9 · 107 · K · P K = belt tension factor, dependent on belt type
D= and type of duty. A common value for
n · FR
V-belts is 2.5.
FR = permissible radial force

Permissible loadings on the shaft end


The table below gives the permissible radial force in Motors are foot-mounted IM B3 version with the force
Newton, assuming zero axial force. The values are directed sideways. In some cases, the strength of the
based on normal conditions and calculated for motor shaft affects the permissible forces.
sizes 280 to 400 of 20,000 and 40,000 hours.
Permissible loads of simultaneous radial and axial forces
will be supplied on request.

Length of Ball bearings Length of Ball bearings


shaft shaft
Motor extension 20,000 hours 40,000 hours Motor extension 20,000 hours 40,000 hours
size E (mm) X0 (N) Xmax(N) X0 (N) Xmax(N) size E (mm) X0 (N) Xmax(N) X0 (N) Xmax(N)

280 SM_ 140 9200 7800 7300 6200 355 SM_ 210 15200 12500 12000 985

315 SM_ 170 11300 9400 9000 7500 355 ML_ 210 15200 12800 12000 10100

315 ML_ 170 11300 9400 9000 7500 400 LK_ 210 15000 13000 11700 10100

If the radial force is applied between points X 0 and Xmax,


the permissible force FR can be calculated from the
following formula:
X
FR = FX0 - (F X0 - FXmax)
E

E = length of shaft extension in basic version

8 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


Operation
1.Motor selection and speed range
The magnetization is achieved by the permanent The direct drive motors can be used at speeds from zero
magnets installed in the rotor, thus the amount of to 1,2 times the nominal speed. The voltage, which is
magnetization current drawn from the supply network is induced by the permanent magnets to the stator windings,
minimal. This means that the power factor of these is proportional to the rotational speed. At speeds higher
motors is considerably higher compared to squirrel cage than 1,2*Nn, the voltage may be too high for the insulation
motors with the same nominal speeds. In practice, this of the motor and supply system. If higher speed is
means smaller frequency converters and supply units. needed, please contact ABB.

The output torque of the permanent magnet motors is The loadability curve in figure 1 below is a guide only, for
constant, but the cooling capabilities may limit the exact values please contact ABB.These guidelines show
actual loadability of the self cooled versions (IC411). the maximum continuous load torque of a motor as a
Motors are also available with external cooling fans function of frequency (speed).
(IC416) and liquid cooling (M2LJ) where motors can
deliver constant torque (CT) all the way to zero speed.
Above the nominal frequency, up to 1,2 times the
nominal speed (Nn), the motors are designed to
produce the constant power (CP).

Figure 1. Permanent magnet synchronous motor loadability with ACS 600


Frequency Converter

Loadability

120 %
100 %
80 %
Torque

IC411
60 %
IC416
40 %
20 %
0%
0.00 0.50 1.00 1.50
Speed / nominal

2. Lubrication
The effectiveness of the motor lubrication should be When the bearing temperature is low and when the motor
checked by measuring the bearing temperature under is running slowly, lubricants containing EP admixtures
normal operating conditions. If the measured tempera- can be used.
ture is higher than +80°C, the relubrication intervals
specified in ABB’s Machine Instructions for permanent 4. Insulation protection
magnet synchronous motors must be shortened; i.e. If the frequency converter has IGBT power components
the relubrication interval should be halved for every with very rapid switching, practically all cables between
15 K increase in bearing temperature. If this is not the converter and the motor will be long. In that case,
possible, please contact ABB. steep voltage pulses and reflections within the cables
increase voltage stresses in the winding of the motor and
therefore, the precautions described in figure 2 on page 10
must be taken to avoid risks of insulation damages.

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 9


5. Bearing currents
Bearing voltages and currents must be avoided in all For motors frame size IEC 280 and upward, additional
motors. When using ABB IGBT frequency converter potential equalisation between the motor frame and the
insulated bearings and/or a properly dimensioned filter at machinery is needed, unless they are installed on a
the converter output must be used according to the common steel fundament. When steel fundament is
instructions in figure 2 below. (For other alternatives and used for the potential equalisation, the high frequency
converter types, please contact ABB) When ordering, conductivity of this connection should be checked.
clearly state the alternative to be used. More information about grounding and cabling of a
variable speed drive can be found from the manual
For more information about bearing currents and volt- “Grounding and cabling of the drive system” (Code:
ages, please consult ABB document 3GZF500930-8 or 3AFY 61201998 R0125 REV A)
contact ABB. To fulfill the EMC requirements, special EMC cable(s)
must be used in addition to the correct cable gland
6. Cabling, grounding and EMC mounting, with special, additional earthing pieces.
The use of a frequency converter causes some further Please refer to the manuals of the frequency converter.
requirements to the cabling and grounding of the drive
system. The motor must be cabled by using shielded
symmetrical cables and cable glands providing 360°
bonding (also called EMC-glands).

Figure 2. Selection rules for insulation and filtering in variable speed drives.
Motor nominal power or frame size
PN < 100 kW PN ≥ 100 kW or ≥ IEC 315 PN ≥ 350 kW or ≥ IEC 400

UN ≤ 500 V Standard motor Standard motor Standard motor


+ Insulated N-bearing + Insulated N-bearing
+ Common mode filter
UN ≤ 600 V Standard motor Standard motor Standard motor
+ dU/dt –filter (reactor) + dU/dt –filter (reactor) + Insulated N-bearing
OR + Insulated N-bearing + dU/dt –filter (reactor)
Reinforced insulation OR + Light common mode filter
Reinforced insulation OR
+ Insulated N-bearing Reinforced insulation
+Insulated N-bearing
+ Common mode filter
UN ≤ 690 V Reinforced insulation Reinforced insulation Reinforced insulation
+ dU/dt –filter (reactor) + dU/dt –filter (reactor) + Insulated N-bearing
+ Insulated N-bearing + dU/dt –filter (reactor)
+ Light common mode filter

dU/dt filter
Series reactor. dU/dt filters decrease the changing rate of the phase and main voltages and thus reduce voltage stresses in
the windings. dU/dt filters also decrease so called common mode currents and bearing currents.
Common mode and light common mode filters
Common mode filters are made of toroidal cores installed around motor cables. These filters reduce so called common mode
currents in VSD applications and thus decrease the risk of bearing currents. Common mode filters do not significantly affect
the phase or main voltages on the motor terminals. For the exact type of the core, please contact ABB.
Common Mode Filter = 3 toroidal cores per each 3-phase motor cable
Light Common Mode Filter = 1 toroidal core per each 3-phase motor cable

10 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


Rating plate
ABB Oy, Electrical Machines
LV Motors, Vaasa, Finland
3 Motor M2BJ 315MLA 12 B3
PERMANENT MAGNET SYNCR. MOTOR
S1 SPEC.INS. No. 1234567
2002 Ins.cl. F IP 55
V Hz kW r/min A cos Duty
370 D 30 80 300 151 0.91
640 Y 30 80 300 87 0.91

Prod.code 3GBJ316410-AXA
INSULATED BEARING AT N-END
6319/C3 6316/C4VLO24 1030 kg

IEC 60034-1

Ordering information
Sample order
When placing an order, the motor type, size and product
code must be specified. The product code of the motor
is composed in accordance with the following example.
Motor size
A B C D, E, F, G A Motor type
B Motor size
M2BJ 280 SMB 3GBJ 316 222 - A D A 003 C Product code
D Mounting arrangement code
1- 4 5-6 7 8 9 10 11 12 13 14 E Voltage and frequency code
F Generation code
G Variant codes
Explanation of the product code:
Positions 1 to 4 Position 11
3GBJ = Totally enclosed fan cooled permanent magnet - (dash)
motor with cast iron frame
Position 12
Positions 5 and 6
Mounting arrangement
IEC-frame
A = Foot-mounted, top-mounted terminal box
28 = 280
31 = 315
35 = 355 Position 13
40 = 400 Voltage and frequency code
Network voltage 400 V/690 V
Position 7
Position 14
Speed (Pole pairs)
Generation code
6 = 12 poles
A, B, C...
The product code must be, if needed, followed by variant
Position 8 to 9
codes.
Serial number
Position 10 Motors, frame size 280, include variant codes 405 and
Base speed 445 as standard.
2 = 220 r/min
3 = 300 r/min Motors, frame sizes 315 to 400, include variant codes 405,
4 = 430 r/min 445 and 701 as standard.
6 = 600 r/min

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 11


Technical data
Permanent magnet synchronous motors, cast iron frame
Network voltage 400 V/690 V4)
220 r/min, field weakening point 370 VD/640 VY, 22 Hz

Efficiency Current 370 V Torque Moment of


Full Power IN TN Tmax inertia
Output Type Product load factor J=1/4 GD2 Weight
kW designation code 100% cos ϕ A Nm TN kgm2 approx. kg

Cooling designation: IC 411


Loadability: Consult chart on page 9 for motor selection
1)
17 M2BJ 280SMB 3GBJ 286 222-ADA 89.3 0.94 34 738 2.0 2.2 630

25 M2BJ 315SMB 3GBJ 316 222-ADA 90.4 0.95 52 1085 2.0 3.9 820
35 M2BJ 315MLA 3GBJ 316 412-ADA 91.5 0.94 68 1519 2.1 5.8 1000

53 M2BJ 355SMA 3GBJ 356 212-ADA 92.8 0.96 95 2301 2.5 14.0 1570
88 M2BJ 355MLC 3GBJ 356 432-ADA 92.7 0.98 158 3820 2.1 19.7 1940

134 M2BJ 400LKC 3GBJ 406 532-ADA 94.6 0.97 240 5816 2.1 40.7 2930
Cooling designation : IC 416 (with external cooling fan, variant code 183)
Loadability: Suitable for CT : 0 - nn , CP: nn - 1.2 x nn3)
1)
25 M2BJ 280SMB 3GBJ 286 222-ADA183 81.7 0.93 50 1085 1.3 2.2 640

40 M2BJ 315SMB 3GBJ 316 222-ADA183 81.9 0.91 80 1736 1.2 3.9 840
55 M2BJ 315MLA 3GBJ 316 412-ADA183 85.7 0.93 105 2387 1.2 5.8 1030

80 M2BJ 355SMA 3GBJ 356 212-ADA183 89.3 0.96 142 3472 1.6 14.0 1590
132 M2BJ 355MLC 3GBJ 356 432-ADA183 89.4 0.96 237 5730 1.3 19.7 1960

200 M2BJ 400LKC 3GBJ 406 532-ADA183 92.3 0.95 360 8681 1.4 40.7 2960

Cooling designation : Water cooled


Loadability: Suitable for CT : 0 - nn , CP: nn - 1.2 x nn3)
1) 2)
25 M2LJ 280SMB 3GLJ 286 222-ADA 85.9 0.93 50 1085 1.3 2.2

2)
40 M2LJ 315SMB 3GLJ 316 222-ADA 85.8 0.91 80 1736 1.2 3.9
2)
55 M2LJ 315MLA 3GLJ 316 412-ADA 88.7 0.93 105 2387 1.2 5.8

2)
80 M2LJ 355SMA 3GLJ 356 212-ADA 91.6 0.96 142 3472 1.6 14.0
2)
132 M2LJ 355MLC 3GLJ 356 432-ADA 90.4 0.96 237 5730 1.3 19.7

2)
200 M2LJ 400LKC 3GLJ 406 532-ADA 93.2 0.95 360 8681 1.4 40.7
1)
In frame size 280 includes variant codes 405 and 445 as standard.
2)
On request Motors include variant codes 405, 445 and 701
3)
CT = Constant torque
as standard, please see the variant codes
CP = Constant power
nn = Nominal speed on pages 16-19.
4)
Other voltages on request

12 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


Technical data
Permanent magnet synchronous motors, cast iron frame
Network voltage 400 V/690 V4)
300 r/min, field weaking point 370 VD/640 VY, 30 Hz

Efficiency Current 370 V Torque Moment of


Full Power IN TN Tmax inertia
Output Type Product load factor J=1/4 GD2 Weight
kW designation code 100% cos ϕ A Nm TN kgm2 approx. kg

Cooling designation: IC 411


Loadability: Consult chart on page 9 for motor selection
1)
25 M2BJ 280SMB 3GBJ 286 223-ADA 91.0 0.95 47 796 1.8 2.2 630

38 M2BJ 315SMB 3GBJ 316 223-ADA 92.1 0.94 73 1210 1.8 3.9 820
55 M2BJ 315MLA 3GBJ 316 413-ADA 93.0 0.95 104 1751 1.8 5.8 1000

78 M2BJ 355SMA 3GBJ 356 213-ADA 94.1 0.97 136 2483 2.2 14.0 1570
132 M2BJ 355MLC 3GBJ 356 433-ADA 94.1 0.96 235 4202 1.9 19.7 1940

200 M2BJ 400LKC 3GBJ 406 533-ADA 95.5 0.97 346 6366 1.9 40.7 2930
Cooling designation : IC 416 (with external cooling fan, variant code 183)
Loadability: Suitable for CT : 0 - nn , CP: nn - 1.2 x nn3)
1)
35 M2BJ 280SMB 3GBJ 286 223-ADA183 85.0 0.92 68 1114 1.3 2.2 640

55 M2BJ 315SMB 3GBJ 316 223-ADA183 86.3 0.91 106 1751 1.2 3.9 840
80 M2BJ 315MLA 3GBJ 316 413-ADA183 88.6 0.91 151 2546 1.2 5.8 1030

110 M2BJ 355SMA 3GBJ 356 213-ADA183 91.5 0.97 191 3501 1.6 14.0 1590
185 M2BJ 355MLC 3GBJ 356 433-ADA183 91.5 0.95 329 5889 1.3 19.7 1960
280 M2BJ 400LKC 3GBJ 406 533-ADA183 93.9 0.95 485 8913 1.4 40.7 2960

Cooling designation : Water cooled


Loadability: Suitable for CT : 0 - nn , CP: nn - 1.2 x nn3)
1) 2)
35 M2LJ 280SMB 3GLJ 286 223-ADA 88.2 0.92 68 1114 1.3 2.2

2)
55 M2LJ 315SMB 3GLJ 316 223-ADA 89.4 0.91 106 1751 1.2 3.9
2)
80 M2LJ 315MLA 3GLJ 316 413-ADA 90.8 0.91 151 2546 1.2 5.8

2)
110 M2LJ 355SMA 3GLJ 356 213-ADA 93.2 0.97 191 3501 1.6 14.0
2)
185 M2LJ 355MLC 3GLJ 356 433-ADA 92.9 0.95 329 5889 1.3 19.7

2)
280 M2LJ 400LKC 3GLJ 406 533-ADA 94.6 0.95 485 8913 1.4 40.7
1)
In frame size 280 includes variant codes 405 and 445 as standard.
2)
On request Motors include variant codes 405, 445 and 701
3)
CT = Constant torque
CP = Constant power
as standard, please see the variant codes
nn = Nominal speed on pages 16-19.
4)
Other voltages on request

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 13


Technical data
Permanent magnet synchronous motors, cast iron frame
Network voltage 400 V/690 V4)
430 r/min, field weakening point 370 VD/640 VY, 43 Hz

Efficiency Current 370 V Torque Moment of


Full Power IN TN Tmax inertia
Output Type Product load factor J=1/4 GD2 Weight
kW designation code 100% cos ϕ A Nm TN kgm2 approx. kg

Cooling designation: IC 411


Loadability: Consult chart on page 9 for motor selection
1)
38 M2BJ 280SMB 3GBJ 286 224-ADA 92.7 0.94 72 844 1.6 2.2 620

56 M2BJ 315SMB 3GBJ 316 224-ADA 93.5 0.94 104 1244 1.7 3.9 820
82 M2BJ 315MLA 3GBJ 316 414-ADA 94.1 0.94 151 1821 1.7 5.8 1000

115 M2BJ 355SMA 3GBJ 356 214-ADA 95.0 0.96 198 2554 2.2 14.0 1570
192 M2BJ 355MLC 3GBJ 356 434-ADA 95.0 0.97 333 4264 1.8 19.7 1940

308 M2BJ 400LKC 3GBJ 406 534-ADA 96.2 0.95 533 6840 1.8 40.7 2930
Cooling designation : IC 416 (with external cooling fan, variant code 183)
Loadability: Suitable for CT : 0 - nn , CP: nn - 1.2 x nn3)
1)
50 M2BJ 280SMB 3GBJ 286 224-ADA183 88.5 0.92 95 1110 1.2 2.2 640

75 M2BJ 315SMB 3GBJ 316 224-ADA183 89.7 0.92 139 1666 1.3 3.9 840
110 M2BJ 315MLA 3GBJ 316 414-ADA183 91.4 0.92 203 2443 1.3 5.8 1030

150 M2BJ 355SMA 3GBJ 356 214-ADA183 93.5 0.96 257 3331 1.7 14.0 1590
250 M2BJ 355MLC 3GBJ 356 434-ADA183 93.4 0.96 432 5552 1.3 19.7 1960

400 M2BJ 400LKC 3GBJ 406 534-ADA183 95.4 0.94 693 8883 1.4 40.7 2960
Cooling designation : Water cooled
Loadability: Suitable for CT : 0 - nn , CP: nn - 1.2 x nn3)
1) 2)
50 M2LJ 280SMB 3GLJ 286 224-ADA 90.9 0.92 95 1110 1.2 2.2

2)
75 M2LJ 315SMB 3GLJ 316 224-ADA 92.1 0.92 139 1666 1.3 3.9
2)
110 M2LJ 315MLA 3GLJ 316 414-ADA 93.1 0.92 203 2443 1.3 5.8

2)
150 M2LJ 355SMA 3GLJ 356 214-ADA 94.8 0.96 257 3331 1.7 14.0
2)
250 M2LJ 355MLC 3GLJ 356 434-ADA 94.4 0.96 432 5552 1.3 19.7

2)
400 M2LJ 400LKC 3GLJ 406 534-ADA 95.9 0.94 693 8883 1.4 40.7
1)
In frame size 280 includes variant codes 405 and 445 as standard.
2)
On request
3)
CT = Constant torque Motors include variant codes 405, 445 and 701
CP = Constant power as standard, please see the variant codes
nn = Nominal speed
4)
Other voltages on request
on pages 16-19.

14 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


Technical data
Permanent magnet synchronous motors, cast iron frame
Network voltage 400 V/690 V4)
600 r/min, field weakening point 370 VD/640 VY, 60 Hz

Efficiency Current 370 V Torque Moment of


Full Power IN TN Tmax inertia
Output Type Product load factor J=1/4 GD2 Weight
kW designation code 100% cos ϕ A Nm TN kgm2 approx. kg

Cooling designation: IC 411


Loadability: Consult chart on page 9 for motor selection
57 M2BJ 280SMB 3GBJ 286 226-ADA 93.8 0.93 105 907 1.55 2.2 620

88 M2BJ 315SMB 3GBJ 316 226-ADA 94.6 0.92 164 1401 1.5 3.9 820
120 M2BJ 315MLA 3GBJ 316 416-ADA 95.2 0.91 219 1910 1.7 5.8 1000

165 M2BJ 355SMA 3GBJ 356 216-ADA 95.6 0.96 280 2626 2.0 14 1570
314 M2BJ 355MLC 3GBJ 356 436-ADA 95.8 0.90 565 4997 1.8 19.7 1940

413 M2BJ 400LKC 3GBJ 406 536-ADA 96.7 0.96 698 6573 1.8 40.7 2930
Cooling designation : IC 416 (with external cooling fan, variant code 183)
Loadability: Suitable for CT : 0 - nn , CP: nn - 1.2 x nn3)
70 M2BJ 280SMB 3GBJ 286 226-ADA183 91.4 0.91 129 1114 1.2 2.2 640

110 M2BJ 315SMB 3GBJ 316 226-ADA183 92.1 0.90 204 1751 1.2 3.9 840
150 M2BJ 315MLA 3GBJ 316 416-ADA183 93.5 0.90 273 2387 1.4 5.8 1030

200 M2BJ 355SMA 3GBJ 356 216-ADA183 94.6 0.96 339 3183 1.7 14 1590
380 M2BJ 355MLC 3GBJ 356 436-ADA183 95.2 0.91 683 6048 1.5 19.7 1960

500 M2BJ 400LKC 3GBJ 406 536-ADA183 96.2 0.96 884 7958 1.5 40.7 2960
Cooling designation : Water cooled
Loadability: SuitableCT : 0 - nn , CP: nn - 1.2 x nn3)
2)
70 M2LJ 280SMB 3GLJ 286 226-ADA 93.2 0.91 129 1114 1.2 2.2

2)
110 M2LJ 315SMB 3GLJ 316 226-ADA 93.8 0.90 204 1751 1.2 3.9
2)
150 M2LJ 315MLA 3GLJ 316 416-ADA 94.8 0.90 273 2387 1.4 5.8

2)
200 M2LJ 355SMA 3GLJ 356 216-ADA 95.6 0.96 339 3183 1.7 14
2)
380 M2LJ 355MLC 3GLJ 356 436-ADA 95.7 0.91 683 6048 1.5 19.7

2)
500 M2LJ 400LKC 3GLJ 406 536-ADA 96.6 0.96 884 7958 1.5 40.7
1)
In frame size 280 includes variant codes 405 and 445 as standard.
2)
On request
3)
CT = Constant torque Motors include variant codes 405, 445 and 701
CP = Constant power as standard, please see the variant codes
nn = Nominal speed
4)
on pages 16-19.
Other voltages on request

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 15


Variant Codes
Code Variant 280 315 355-400
1)

Balancing
424 Full key balancing. P P P

Bearings and lubrication


036 Transport lock for bearings. M M M
037 Roller bearing at D-end. R R R
039 Cold resistant grease.
For bearing temperatures -55 - +100°C. M M M
041 Bearings regreasable via grease nipples. S S S
042 Locked drive-end. S S S
043 SPM nipples. S S S
107 Bearing mounted PT100 resistance elements. P P P
108 Continuous bearing monitoring (SPM system 32). P P P
420 Bearing mounted PTC thermistors. P P P
701 Insulated bearing at N-end R S S

Branch standard designs


178 Stainless steel/acid proof bolts. M M M
209 Non-standard voltage or frequency (special winding). R R R
419 Textile industry design. R R R
425 Corrosion protected stator and rotor core. P P P
785 Reinforced tropicalisation. R R R

Cooling system
044 Unidirectional fan, clockwise seen from D-end. R R R
045 Unidirectional fan, counter clockwise seen from D-end. R R R
054 Special fan for noise reduction. R R R
068 Metal fan.
Mandatory for ambient temperatures ≥ 60°C. R R R
490 Plastic fan with metal hub. R R R
183 Separate motor cooling (fan axial, N-end). P P P
422 Separate motor cooling (fan top or side, N-end). P P P
791 Stainless steel fan cover. P P P

Coupling
035 Assembly of customer supplied coupling-half (finish bored and balanced). R R R

Dimension drawing
141 Binding dimension drawing. M M M

Drain holes
065 Plugged existing drain holes. M M M
066 Modified drain hole position (for specified IM xxxx). M M M
076 Draining holes with plugs. S S S

1)
Certain variant codes cannot be used simultaneously. S = Included as standard P = New manufacture only.
M = On modification of a stocked motor, R = On request.
or on new manufacture, NA = Not applicable
the number per order may be limited.

16 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


Code Variant Motor size
1)
280 315 355-400

Earthing bolt

067 External earthing bolt. S S S

Heating elements
450 Heating element, 100-120 V. M M M
451 Heating element, 200-240 V. M M M

Insulation system

014 Winding insulation class H. P P P


405 Special winding insulation for frequency converter supply, S S S
rated supply > 500 V.
406 Winding for supply > 690 ≤ 1000 V. P P P

Mounting arrangements
009 IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3). R R R

Noise reduction

055 Noise reducing cover P P P

Painting
114 Special paint colour, standard grade. M M M
115 Offshore zink primer painting. R R R
179 Special paint specification. R R R

Protection
072 Radial seal at D-end. M M M
073 Sealed against oil at D-end. R R R
401 Protective roof, horizontal motor. P P P
403 Degree of protection IP 56. P P M
783 Labyrinth sealing at D-end. M M M

Rating & instruction plates

002 Restamping voltage, frequency and output, continuous duty. R R R


003 Individual serial number. S S S
095 Restamping output (maintained voltage, frequency),
intermittent duty. M M M
098 Stainless rating plate. S S S
135 Mounting of additional identification plate, stainless. M M M
138 Mounting of additional identification plate, aluminium. M M M
139 Additional identification plate delivered loose. M M M
150 Instruction plates and maintenance instructions
in non-standard language. R R R
161 Additional rating plate delivered loose. M M M

1)
Certain variant codes cannot be used simultaneously. S = Included as standard P = New manufacture only.
M = On modification of a stocked motor, R = On request.
or on new manufacture, NA = Not applicable
the number per order may be limited.

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 17


Code Variant Motor size
1)
280 315 355-400

Shaft & rotor


069 Two shaft extensions as per basic catalogue. P P P
070 One or two special shaft extensions. P P P
155 Cylindrical shaft extension, D-end, without key-way. P P P
156 Cylindrical shaft extension, N-end, without key-way. P P P
164 Shaft extension with closed key-way. P P P
165 Shaft extension with open key-way. S S S
410 Stainless/acid-proof steel shaft (standard or
non-standard design). One or two extensions. R R R
427 Shaft extension complies with Australian Standards (AS). P P P
431 Special shaft material for low temperatures, -40°C. P P P
Stator winding temperature sensors
Breaking capacity for bimetal detector:
Sizes 280-400
24 A at 250 V

121 Bimetal detectors, break type (NCC), (3 in series), 130°C, in stator winding. M M M
122 Bimetal detectors, break type (NCC), (3 in series), 150°C, in stator winding. M M M
123 Bimetal detectors, break type (NCC), (3 in series), 170°C, in stator winding. M M M
125 Bimetal detectors, break type (NCC), (2x3 in series), 150°C, in stator winding. M M M
127 Bimetal detectors, break type (NCC), (3 in series, 130°C and
3 in series, 150°C), in stator winding. M M M
435 PTC - thermistors (3 in series), 130°C, in stator winding.
Two speed motors, only for new manufacture. M M M
436 PTC - thermistors (3 in series), 150°C, in stator winding.
Two speed motors, only for new manufacture. S S S
437 PTC - thermistors (3 in series), 170°C, in stator winding.
Two speed motors, only for new manufacture. M M M
439 PTC - thermistors (2x3 in series), 150°C, in stator winding.
Two speed motors, only for new manufacture. M M M
441 PTC - thermistors (3 in series, 130°C and 3 in series,
150°C, in stator winding. Two speed motors, only for new manufacture. M M M
442 PTC - thermistors (3 in series, 150°C and 3 in series, 170°C, in stator winding.
Two speed motors, only for new manufacture. M M M
445 PT100 (1 per phase) in stator winding. S S S
446 PT100 (2 per phase) in stator winding. M M M
Terminal box
015 Motor supplied in D-connection. M M M
017 Motor supplied in Y-connection. M M M
019 Larger than standard terminal box. R R R
021 Terminal box LHS (seen from D-end). R R R
180 Terminal box RHS (seen from D-end). R R R
137 Extended cable connection, low terminal box, "Flying leads". P P R
230 Standard cable glands. S S S
400 4 x 90 degr turnable terminal box. P P M
402 Terminal box adapted for Al cables. S S M
418 Separate terminal box for temperature detectors. P P P

1)
Certain variant codes cannot be used simultaneously. S = Included as standard P = New manufacture only.
M = On modification of a stocked motor, R = On request.
or on new manufacture,
the number per order may be limited.

18 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


Code Variant Motor size
1)
280 280 355-400

466 Terminal box at N-end. P P P

704 EMC cable termination M M M


731 Two standard cable glands. S S S

Testing

148 Routine test report. M M M


760 Vibration level test. M M M
761 Vibration spectrum test. M M M
762 Noise level test. M M M
763 Noise spectrum test. M M M
764 Complete test with ABB frequency converter M M M

Pulse tacho & separate cooling

Cooling system
183 Separate motor cooling (fan axial, N-end). P P P
422 Separate motor cooling (fan top or side, N-end). P P P
Mounting of tacho; tacho not included
182 Pulse sensor mounted as specified (Leine & Linde equivalent, hollow-shaft type). P P P
470 Prepared for hollow shaft pulse tacho (Leine&Linde equivalent). P P P
479 Mounting of other types of tachos with shaft extension. P P P
Mounting of tacho; tacho included
062 Tachogenerator. P P P
471 512 hollow shaft pulse tacho (Leine&Linde equivalent) mounted. P P P
472 1024 hollow shaft pulse tacho (Leine&Linde equivalent) mounted. P P P
473 2048 hollow shaft pulse tacho (Leine&Linde equivalent) mounted. P P P
Separate motor cooling & tacho; tacho not included
474 Separate motor cooling and prepared for hollow shaft
pulse tacho (Leine&Linde equivalent). P P P
478 Separate motor cooling (fan top, N-end) and prepared for hollow shaft
pulse tacho (Leine&Linde equivalent. P P P
Separate motor cooling & tacho; tacho included
428 Separate motor cooling (fan top, N-end) and Leine &
Linde, type 510 006361, pulse tacho. P P P
429 Separate motor cooling (fan top, N-end) and Leine &
Linde, type 861007455, hollow shaft pulse tacho. P P P
475 Separate motor cooling (fan axial, N-end) and 512
hollow shaft pulse tacho (L&L equivalent). P P P
476 Separate motor cooling (fan axial, N-end) and 1024
hollow shaft pulse tacho (L&L equivalent). P P P
477 Separate motor cooling (fan axial, N-end) and 2048
hollow shaft pulse tacho (L&L equivalent). P P P

1)
Certain variant codes cannot be used simultaneously. S = Included as standard P = New manufacture only.
M = On modification of a stocked motor, R = On request.
or on new manufacture,
the number per order may be limited.

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 19


Permanent magnet motors Sizes 280-315
Cooling designation: IC 411
Dimension drawings
Foot-mounted

2)

Motor A AA AB AC B B' BA BB C CA CA' D DA DB DC E EA EG EH


size

280 SM_ 457 85 530 572 368 419 146 506 190 400 349 75 65 M20 M20 140 140 40 40
315 SM_ 508 100 590 645 406 457 163 556 216 465 414 80 75 M20 M20 170 140 40 40

315 ML_ 508 100 590 645 457 508 163 607 216 465 414 90 75 M24 M20 170 140 48 40

Motor F FA G GA GB GC GD GF H HA HC HD K L LC LD O
2)
size

280 SM_ 20 18 67.5 79.5 58 69 12 11 280 40 566 745 24 1088 1238 332 100

315 SM_ 22 20 71 85 67.5 79.5 14 12 315 50 638 840 30 1248 1397 381 115

315 ML_ 25 20 81 95 67.5 79.5 14 12 315 50 638 840 30 1299 1448 381 115
1)
Tolerances: Cooling distance.
2)
D,DA ISO m6 Second shaft end on request.
H ISO 0, - 1.0 Above table gives the main dimensions in mm.
For detailed drawings please contact us.

20 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


Permanent magnet motors Sizes 355-400
cooling designation: IC 411
Dimension drawings
Foot-mounted

Motor A AA AB AC B B' BA BB C CA CA' D DA DB DC E EA EG EH


size

355 SM_ 610 120 700 740 500 560 161 722 254 512 452 100 90 M24 M24 210 170 48 48
355 ML_ 610 120 700 740 560 630 161 792 254 557 487 100 90 M24 M24 210 170 48 48
400 LK_ 686 140 820 824 710 800 170 967 280 558 468 100 90 M24 M24 210 170 48 48

Motor F FA G GA GB GC GD GF H HA HC HD K L LC LD O si
1)
size

355 SM_ 28 25 90 106 81 95 16 14 355 55 725 955 35 1466 1646 467 130
355 ML_ 28 25 90 106 81 95 16 14 355 55 725 955 35 1571 1751 467 130
400 LK_ 28 25 90 106 81 95 16 14 400 55 812 1040 35 1748 1928 502 150
1)
Tolerances: Cooling distance.
D,DA ISO m6
H ISO 0, - 1.0 Above table gives the main dimensions in mm.
For detailed drawings please contact us.

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 21


Permanent magnet motors Sizes 280 - 315
Cooling designation: IC 416, variant code 183;
Separate motor cooling, fan axial, N-end
Dimension drawings
Foot-mounted

Motor A AA AB AC B B’ BA BB C D DB E
size
280 SM_ 457 85 530 572 368 419 134 506 190 75 M20 140
315 SM_ 508 100 590 645 406 457 163 556 216 80 M20 170

315 ML_ 508 100 590 645 457 508 163 607 216 90 M20 170

Motor F G GA GD H HA HC HD K L LC LD O
size
280 SM_ 20 67.5 79.5 12 280 40 566 745 24 1100 1370 332 25
315 SM_ 22 71 85 14 315 50 638 840 30 1225 1523 381 25
315 ML_ 25 81 95 14 315 50 638 840 30 1276 1574 381 25

Above table gives the main dimensions in mm.


For detailed drawings please contact us.

22 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


Permanent magnet motors Sizes 355 - 400
Cooling designation: IC 416, variant code 183;
Separate motor cooling, fan axial, N-end
Dimension drawings
Foot-mounted

Motor A AA AB AC B B’ BA BB C D DB E EG
size
355 SM_ 610 120 700 740 500 560 161 722 254 100 M24 210 48

355 ML_ 610 120 700 740 560 630 161 792 254 100 M24 210 48
400 LK_ 686 140 820 824 710 800 170 967 280 100 M24 210 48

Motor F G GA GD H HA HC HD K L LC LD O
size
355 SM_ 28 90 106 16 355 55 725 955 35 1488 1786 467 25
355 ML_ 28 90 106 16 355 55 725 955 35 1593 1891 467 25

400 LK_ 28 90 106 16 400 55 812 1040 35 1770 2068 502 25

Above table gives the main dimensions in mm.


For detailed drawings please contact us.

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 23


Permanent magnet motors Sizes 280 - 315
Cooling designation: IC 416, variant code 422;
Separate motor cooling, fan top or side, N-end.
Dimension drawings
Foot-mounted

Motor A AA AB AC B B’ BA BB C D DB E EG F
size
280SM_ 457 85 530 572 368 419 134 506 190 75 M20 140 40 20
315SM_ 508 100 590 645 406 457 163 556 216 80 M20 170 40 22

315ML_ 508 100 590 645 457 508 163 607 216 90 M24 170 48 25

Motor G GA GD H HA HC HD H1 K L L’ LD O O’
size
280SM_ 67.5 79.5 12 280 40 566 745 1250 24 1125 1317 332 130 25
315SM_ 71 85 14 315 50 638 840 1320 30 1210 1397 381 130 25
315ML_ 81 95 14 315 50 638 840 1320 30 1261 1448 381 130 25

Above table gives the main dimensions in mm.


For detailed drawings please contact us.

24 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


Permanent magnet motors Sizes 355 - 400
Cooling designation: IC 416, variant code 422;
Separate motor cooling, fan top or side, N-end.
Dimension drawings
Foot-mounted

Motor A AA AB AC B B’ BA BB C D DB E EG F
size

355 SM_ 610 120 700 740 500 560 161 722 254 100 M24 210 48 28
355 ML_ 610 120 700 740 560 630 161 792 254 100 M24 210 48 28

400 LK_ 686 140 820 824 710 800 170 967 280 100 M24 210 48 28

Motor G GA GD H HA HC HD H1 K L L’ LD O O’
size
355 SM_ 90 106 16 355 55 725 955 1500 35 1471 1701 467 130 25
355 ML_ 90 106 16 355 55 725 955 1500 35 1576 1806 467 130 25

400 LK_ 90 106 16 400 55 812 1040 1588 35 1745 2000 502 130 25

Above table gives the main dimensions in mm.


For detailed drawings please contact us.

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 25


Permanent magnet motors Sizes 280-315
cooling designation: Water cooled
Dimension drawings
Foot-mounted

Motor A AA AB AC B B’ BA BB C D DB E EG
1)
size
280 SM_ 457 85 530 544 368 419 135 470 190 75 M20 140 40

315 SM_ 508 100 590 615 406 457 130 537 216 80 M20 170 40
315 ML_ 508 100 590 615 457 508 130 588 216 90 M24 170 48

Motor F G GA GD H HA HD K L LD X Y
1)
size
280 SM_ 20 67.5 79.5 12 280 40 745 24 932 332 390 300
315 SM_ 22 71 85 14 315 50 840 30 1042 381 440 350

315 ML_ 25 81 95 14 315 50 840 30 1093 381 440 400


1)
Tolerances:
D ISO m6 Above table gives the main dimensions in mm.
H ISO 0, -1.0 For detailed drawings please contact us.

26 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


Permanent magnet motors Sizes 355-400
Cooling designation: Water cooled
Dimension drawings
Foot-mounted

Motor A AA AB AC B B’ BA BB C D DB E E’ EG
1) 2)
size
355 SM_ 610 120 700 700 500 560 161 667 254 100 M24 210 190 48
355 ML_ 610 120 700 700 560 630 161 772 254 100 M24 210 190 48
400 LK_ 686 140 820 790 710 800 195 937 280 100 M24 210 190 48

Motor F G GA GD H HA HD K L LD X Y Z
1) 2)
size
355 SM_ 28 90 106 16 355 55 955 35 1282 467 530 450 180

355 ML_ 28 90 106 16 355 55 955 35 1387 467 530 550 180
400 LK_ 28 90 106 16 400 55 1040 35 1564 502 600 600 180
1)
Tolerances:
D ISO m6 Above table gives the main dimensions in mm.
H ISO 0, -1.0 For detailed drawings please contact us.
2)
Note: Motor sizes 355 to 400 with a bearing fan.

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 27


Dimension drawings
Permanent magnet motors
Terminal box in standard design with 6 terminals

Top-mounted terminal box:

122/2 162/1, 162/2 +


142/1, 142/2 adaptor MPMM-ZL1

Terminal box type Motor size A1 B1 H1 Terminal box type Motor size A1 B1 H1
122/2 280 455 280 177 162/1, 162/2 + 355 - 400 787 410 226
Adapter MPMM-ZL1
142/1, 142/2 315 - 355 536 349 197

Further details on terminal boxes on page 6.

For motor dimensions please see dimension drawings on earlier pages.

28 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


Permanent magnet motors in brief
Motor size 280 315 355 400

Stator Material Cast iron EN-GJL-200/GG 20/GRS 200


Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G
Paint thickness Two-pack epoxy paint, thickness ≥ 70 µm

Bearing end shields Material CI EN-GJL200/GG 20/GRS 200, except flange-mounted IEC 355-400
Spheroidal graphit GG40/GRP400
Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G
Paint thickness Two-pack epoxy paint, thickness ≥ 70 µm

Bearings D-end 6316-C3 6319-C3 6322-C3 6322-C3


N-end 6316-C3 6316M-C4VL024 6319M-C4VL024 6319M-C4VL024

Axially-locked Inner bearing cover As standard, locked at D-end


bearings

Bearing seals V-ring as standard, radial seal on request

Lubrication Regreasable bearings, regreasing nipples, M10x1

SPM-nipples As standard

Rating plate Material Acid proof stainless steel AISI 316


thickness 0.6 mm

Terminal box Frame material Cast iron EN-GJL150/GG 15/GRS 150


Cover material Cast iron 3N-GJL150/GG 15/GRS 150
Cover screws material Steel 5G, coated with zinc and yellow cromated

Connections Cable- 2xM63 2xM63 2xM63 2xØ60/80


entries
Terminals 6 terminals for connection with cable lugs (not included)
Cable glands Cable glands included as standard

Fan Material Glass fibre reinforced plastic, aluminium


or polypropylene with metal hub

Fan cover Material Steel


Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G
Paint thickness Two-pack epoxy polyester powder paint,

Stator winding Material Copper


Insulation Insulation class F
Winding protection 3 PTC thermistors as standard, 150°C

Rotor winding Material Permanent magnet rotor

Balancing method Half key balancing as standard


Key way Open key way
Heating elements On request 50 W 2x50 W 2x65 W 2x65 W
Drain holes Standard, open on delivery

Enclosure IP 55, higher protection on request


Cooling method IC 411, IC 416

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 29


DriveIT Low Voltage Motors’ total
product offer

M2000 range
Motor type IEC frame size Output kW

Aluminium motors 56 - 132 0.055 - 7.5 kW


Cast iron motors 71 - 355 0.25 - 250 kW

M3000 range
Motor type IEC frame size Output kW
Aluminium motors 56 - 280 0.055 - 95 kW
Cast iron motors 71 - 400 0.25 - 710 kW
Steel motors 280 - 400 75 - 630 kW
Hazardous area motors 71 - 400 0.25 - 630 kW
Marine motors 56 - 400 0.06 - 630 kW
Open drip proof motors (IP 23) 250 - 400 75 - 800 kW
Brake motors 63 - 160 0.12 - 15 kW
Single-phase motors 56 - 100 0.07 - 2.2 kW
Permanent magnet motors 280 - 400 17 - 500 kW
Integral motors 71 - 100 0.37 - 2.2 kW
Wind turbine generators 280 - 400 > 1 MW

NEMA frame size Output HP


NEMA motors 404 - 587 100 - 700 HP

Special types/alternatives
– high speed motors, over 3000 r/min – smoke venting design
– motor adjusted with a holding brake – fan application motors
– motors for roller table drives – slip-ring motors
– water cooled motors – stator/rotor units

Catalogues and brochures for


these motors are available from:

ABB
Electrical Machines
Marketing communications
P.O.Box 633
FIN-65101 Vaasa
tel. +358 (0) 10 22 11
fax +358 (0) 10 22 43575
www.abb.com/motors&drives

30 ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002


Visit our web site
www.abb.com/motors&drives

Motors & Drives


⇒ Low Voltage Motors
⇒ Product Range
Standard motors
M3000
Premium efficiency motors
Process motors
Hazardous area motors
Marine motors
Brake motors
⇒ Permanent magnet motors
Wind turbine generators
Roller table motors
Single phase motors
Fan application motors
Water-cooled motors
M2000
Aluminium motors
Cast iron motors
Library of documents
Local contacts
Motor availability
Fact Files

ABB/ LV Motors / Cat. BA/Permanent Magnet Motors GB 10-2002 31


DriveIT Low Voltage Motors

Printed in Finland, Waasa Graphics Oy, 10-2002/3.000


Manufacturing sites (*) and some of the larger sales companies.

Australia Finland* Japan Sweden*


ABB Industry Pty Ltd ABB Oy ABB K.K. ABB Automation Technology
2 Douglas Street LV Motors 26-1 Cerulean Tower Products AB
Port Melbourne, P.O.Box 633 Sakuragaoka-cho, Shibuya-ku Motors & Machines
Victoria, 3207 FIN-65101 Vaasa Tokyo 150-8512 LV Motors
Tel: +61 (0) 3 9644 4100 Tel: +358 (0) 10 22 11 Tel: +81 (0) 3 578 46251 S-721 70 Västerås
Fax: +61 (0) 3 9646 9362 Fax: +358 (0) 10 22 47372 Fax: +81 (0) 3 578 46260 Tel: +46 (0) 21 329 000
Fax: +46 (0) 21 124 103
Austria France Korea
ABB AG ABB Automation ABB Korea Ltd. Switzerland
Wienerbergstrasse 11 B Rue du Général de Gaulle 7-9fl, Oksan Bldg., 157-33 ABB Switzerland Ltd
A-1810 Wien Champagne-sur-Seine Sungsung-dong, Kangnam-ku Normelec/CMC Components
Tel: +43 (0) 1 601 090 F-77811 Moret-sur-Loing Cedex Seoul Motors&Drives
Fax: +43 (0) 1 601 09 8305 Tel: +33 (0) 1 60 746 500 Tel: +82 2 528 2329 Badenerstrasse 790
Fax: +33 (0) 1 60 746 565 Fax: +82 2 528 2338 Postfach
Belgium CH-8048 Zürich
Asea Brown Boveri S.A.-N.V. Germany Mexico Tel: +41 (0) 58 586 0666
Hoge Wei 27 ABB Automation Products ABB México, S.A. de C.V. Fax: +41 (0) 58 586 0603
B-1930 Zaventem GmbH Apartado Postal 111
Tel: +32 (0) 2 718 6311 P.O.Box 10 02 61 CP 54000 Tlalnepantla Taiwan
Fax: +32 (0) 2 718 6657 D-68002 Mannheim Edo. de México, México Asea Brown Boveri Ltd
Tel: +49 (0) 621 3810 Tel: +52 5 328 1400 P.O.Box 81-54
Brazil Fax: +49 (0) 621 381 6820 Fax: +52 5 390 3720 Taipei
Asea Brown Boveri Ltda Tel: +886 (0) 2 579 9340
P.O.Box 00975 Hong Kong The Netherlands Fax: +886 (0) 2 577 9434
06020-902 Osasco -SP ABB Automation Limited ABB B.V.
Tel: +55 (0) 11 7088 9526 3 Dai Hei Street Dept. LV motors (APP2R) Thailand
Fax: +55 (0) 11 7088 4523 Tai Po Industrial Estate P.O.Box 301 ABB Limited
Tai Po New Territories NL-3000 AH Rotterdam 5th Building, 322 Moo 4
Canada Hong Kong Tel: +31 (0) 10 4078 879 Bangpoo Industrial Estate Soi 6
ABB Inc., BAElectrical Machines Tel: +852 292 938 38 Fax: +31 (0) 10 4078 345 Sukhumvit Road, Prekasa,
10300 Henri-Bourassa Blvd, Fax: +852 292 938 87 Muang, Samutprakarn 10280
West, Saint-Laurent, Quebec New Zealand Tel: +662 (0) 709 3346
Canada H4S 1N6 India* ABB Automation Fax: +662 (0) 709 3765
Tel: +1 514 832-6583 Asea Brown Boveri Ltd Motor Sales
Fax: +1 514 332-0609 P.O.Box 16 P.O.Box 22167 The United Kingdom
Faridabad 121 001 Otahuhu, Auckland ABB Automation Ltd
China* Tel: +91 (0) 882 3001 Tel: +64 (0) 9 276 6016 9 The Towers, Wilmslow Road
ABB Yuejin Motors (Shanghai) Fax: +91 (0) 882 3006 Fax: +64 (0) 9 276 1303 Didsbury
Company Limited Manchester, M20 2AB
8 Guang Xing Rd.,Rong Bei Indonesia Norway Tel: +44 (0) 161 445 5555
Town, Songjiang County, P.T. Abdibangun Buana ABB AS Fax: +44 (0) 161 448 1016
Shanghai 201613 P.O.Box 3781 Automation Technology Products
Tel: +86 21 5778 0988 Jakarta 10002 Division USA
Fax: +86 21 5778 1364 Tel: +62 (0) 21 314 9115 P.O.Box 6540 Rodeloekka ABB Inc.
Fax: +62 (0) 21 315 3963 N-0501 Oslo 5 Electrical Machines
Chile Tel: +47 22 872 000 P.O.Box 372
Asea Brown Boveri S.A. Ireland Fax: +47 22 872 541 Milwaukee
P.O.Box 581-3 Asea Brown Boveri Ltd WI 53201-0372
Santiago Components Division Singapore Tel: +1 262 785 3200
Tel: +56 (0) 2 5447 100 Belgard Road ABB Industry Pte Ltd Fax: +1 262 785 8628
Fax: +56 (0) 2 5447 405 Tallaght, Dublin 24 P.O.Box 95
Tel: +353 (0) 1 405 7300 Pasir Panjang Post Office Venezuela
Denmark Fax: +353 (0) 1 405 7327 Singapore 9111 Asea Brown Boveri S.A.

Catalogue BA/M3000 Permanent Magnet GB 10-2002


ABB A/S Tel: +65 775 3777 P.O.Box 6649
Automation Technology Electrical Italy* Fax: +65 778 0222 Carmelitas,
Machines ABB Industria SpA Caracas 1010A
Petersmindevej 1 BAU LV Motors Spain* Tel: +58 (0) 2 238 2422
DK-5000 Odense C Via Della Meccanica, 22 ABB Automation Products S.A. Fax: +58 (0) 2 239 6383
Tel: +45 65 477 070 I-20040 Caponago - MI Division Motores
Fax: +45 65 477 713 Tel: +39 02 959 6671 P.O.Box 81
Fax: +39 02 959 667216 E-08200 Sabadell
Tel: +34 93 728 8500
Fax: +34 93 728 8741

http://www.abb.com/motors&drives
http://online.abb.com/motors&drives

S-ar putea să vă placă și