Cl. II, Div. 1, Groups E, F, G Dust-Ignitionproof Cl. II, Div. 2, Groups F, G Cl. III
Standard Materials: 5F
Applications: UNY UNF
UNY and UNF unions are installed in • UNY, UNF unions – 1/2" to 1" – steel Male Female threaded thickwall conduit systems: • UNY, UNF unions – 11/4" to 6" – Feraloy® • UNY – to connect conduit to a conduit iron alloy fitting, junction box or device enclosure • UNL, UNA unions – Feraloy iron alloy • UNF – to connect conduit to conduit, or • EL elbows – Feraloy iron alloy or ductile to provide a means for future iron modification of the conduit system UNA unions are used in conduit and fitting Standard Finishes: installations when entrance angle is • Steel – electrogalvanized with chromate between 90° and 180°. treatment EL elbows are installed in conduit run or in • Feraloy iron alloy, malleable iron – box or fitting hub: /2" – 4" 1 1 /2" – 4" electrogalvanized and aluminum acrylic • To change direction in threaded rigid paint conduit run by 90°, or when terminating at a box or fitting Options: Description Suffix Features: Copper-free aluminum SA UNY, UNF and UNL unions have: Not available on UNA or 5" and • Compact design which permits 6" UNY/UNF assembly with a minimum of clearance 5" – 6" 5" – 6" to other adjacent conduit and/or Size Cat. # Size Cat. # equipment • Strong and durable construction UNL 1 /2 UNY105 /2 1 UNF105 UNA unions: 1 /2 female UNY215 /4 to 1/2 3 UNF215 to 3/4 male • Have a single clamping nut on angle, 3 /4 UNY205 /4 3 UNF205 making it both a union and a connector 1 UNY305 1 UNF305 • Permit conduit joints at angles between 11/4 UNY405 11/4 UNF405 90° and 180° 11/4 UNY406 11/4 UNF406 EL elbows have a smooth interior and are 11/2 UNY505 11/2 UNF505 both strong and compact. 11/2 UNY506 11/2 UNF506 2 UNY605 2 UNF605 Certifications and 2 UNY606 2 UNF606 Compliances: 90° Angle 21/2 UNY705 21/2 UNF705 Size Cat. # 21/2 UNY706 21/2 UNF706 • NEC/CEC: 3 UNY805 3 UNF805 Class I, Division 1 & 2, Groups A, B, C, D 1 /2 to 1/2 UNL105 3 UNY806 3 UNF806 3 /4 female to 1/2 male UNL125 31/2 UNY905 31/2 UNF905 Class II, Division 1, Groups E, F, G 1 /2 female to 3/4 male UNL215 4 UNY1005 4 UNF1005 Class II, Division 2, Groups F, G 3 /4 to 3/4 UNL205 5 UNY012 5 UNF012 Class III 6 UNY014 6 UNF014 Dimensions EL 1/2", 3/4", 1" In Inches: UNY UNF UNF/UNY 105, -215, -205, -305 Max. Max. UNL 105, -125, -215, -205 Size Length Dia. Length Dia. Class I, Division 1 & 2, Groups B, C, D 1 /2 23/8 11/2 113/16 11/2 Class II, Division 1, Groups E, F, G 3 /4 – 1/2 27/16 113/16 13/4 113/16 Class II, Division 2, Groups F, G 3 /4 27/16 113/16 13/4 113/16 Class III 1 23/4 17/8 2 17/8 UNF/UNY406, -506, 11/4 33/16 23/4 21/4 23/4 11/2 39/16 31/16 25/8 31/16 -606, -706, -806, 2 33/4 313/16 29/16 313/16 -905, -1005 21/2 45/8 45/16 33/16 45/16 Class I, Division 1 & 2, Groups C, D 3 5 51/ 16 37/16 51/16 Class II, Division 1, Groups E, F, G 31/2 51/2 511/16 41/8 511/16 Class II, Division 2, Groups F, G 4 55/8 63/ 16 41/8 63/16 5 51/4 83/ 16 313/16 83/16 Class III 6 53/8 95/ 16 313/16 95/16 EL, UNF, UNL, UNY - all sizes Class I, Division 1 & 2, Group D UNL Class II, Division 1, Groups E, F, G Dim. 105 125 215 205 Class II, Division 2, Groups F, G a 211/16 211/16 27/8 27/8 Class III b 117/32 113/16 113/16 113/16 c 21/16 21/16 21/4 21/4 UNA d 17/16 17/16 15/8 15/8 • UL Standard: 886 • CSA Standard: C22.2 No. 30 †See compliances for classification of each product.