Sunteți pe pagina 1din 31

Welcome to today’s Hilti Webinar

Fundamentals of Post-Installed Rebar Design Using Qualified Adhesive Anchor Systems

WEBINAR PRESENTATION SLIDES


Today’s presentation is available now in the handout section of the GoToWebinar control panel
on your screen

CONNECTIVITY
If possible, please be sure you are connected to a secure network.

GROUP ATTENDEES
If you are attending in a group, please have one member of your team visit the following site to
submit all attendees in your group: https://www.us.hilti.com/webinar-group-sign-in.

CEU CREDITS
This course is approved by NCSEA Diamond Review for one (1) Professional Development Hour

WHEN DO I RECEIVE MY CERTIFICATE?


The follow-up emails with participation certificate for all attendees will be sent by Fri., August 4th

FUNDAMENTALS OF
POST-INSTALLED
REBAR DESIGN USING
QUALIFIED ADHESIVE
ANCHOR SYSTEMS
Abraham Chapa
Field Engineer

1
Fundamentals of Post-installed Reinforcing Bar
Design Using Qualified Adhesive Anchor Systems

Abraham Chapa
Hilti Field Engineer

Continuing education credits will be issued for all attendees of today’s


webinar. One (1.0) hour credit is approved by NCSEA. Instructions on
how to receive a certificate will be given at the end of the broadcast.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 3

AGENDA

Fundamental Principles of Anchor and Rebar Theory


Building Code Requirements and Acceptance Criteria for Post-Installed Rebar
Adhesive System Selection
Installation and Location of Post-Installed Reinforcing Bars Procedure
Specification and Detailing - Best Practice
Rebar Design Resources
Summary

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 4

2
ADHESIVE ANCHORS ARE USED IN A VARIETY OF
CONSTRUCTION APPLICATIONS

Structural anchor bolts

Rebar doweling

Safety related applications

Attachments to solid and hollow masonry

Fastening metal fixtures or equipment

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 5

ADHESIVE ANCHOR APPLICATIONS CAN BE DIVIDED INTO


TWO MAIN CATEGORIES: ANCHORING AND REBAR

Rebar
Adhesive
Threaded Rod

+ Torque Controlled
Threaded Rod

Internally
Threaded Insert

Adhesive anchors are regulated by a variety of codes and standards


including ACI 318, ACI 355.4, CSA A23.3 as well as acceptance criteria issued
by the ICC Evaluation Service

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 6

3
THESE TWO APPLICATIONS ARE GOVERNED BY TWO
DESIGN THEORIES: ANCHOR AND REBAR THEORY
Anchor Theory Rebar Theory
Adhesive + Rod Adhesive + Rebar

+ +

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 7

ANCHOR THEORY IS WELL ESTABLISHED IN THE CODES


AND STANDARDS FOR ADHESIVE ANCHORS.
• Failure modes (in tension) include
• Steel
• Concrete Breakout
• Pull-Out / Bond Failure
• Side-Face Blowout and Splitting
• Limited to embedment depths of 20 bar diameters (20d)

Typically, the required strength is established as follows:


øRn ≥ U , where U is the factored load, ø is a strength reduction factor,
and Rn is the nominal resistance (generally taken as the 5% fractile)

For tension loads, splitting of the concrete is typically not relevant due to the
limitations placed on edge distance, concrete thickness, and anchor spacing.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 8

4
A CLOSER LOOK AT REBAR APPLICATIONS…
Applications involving extension of existing construction with new elements using Hilti HIT-RE 500 V3 and Hilti HIT-HY 200

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 9

A CLOSER LOOK AT REBAR APPLICATIONS…


Structural strengthening applications using Hilti HIT-RE 500 V3

Applications in bridge rehabilitation with post-installed reinforcing bars

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 10

5
POST-INSTALLED REINFORCING BARS HAVE A FEW
FUNDAMENTAL DISTINCTIONS COMPARED TO ANCHORS
Post-installed rebar can be characterized as follows:
• Embedded in adhesive in a hole drilled into existing
structure on one side of the interface and cast into new
on the other side.
• Often installed with minimal edge distance resulting in
splitting as the failure mode.
• Typically not designed to resist direct shear loading in
the manner of an anchor bolt.
• Generally embedded as required to “develop” their yield
strength using the development splice length provisions
of the code.

Assumption of bar development is the most fundamental distinction


separating post-installed rebar from adhesive anchors.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 11

TYPICAL REBAR APPLICATIONS FOR POST-INSTALLED


REINFORCING BARS

Tension lap splice

Shear dowels Starter bars

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 12

6
AGENDA

Fundamental Principles of Anchor and Rebar Theory


Building Code Requirements and Acceptance Criteria for Post-Installed Rebar
Adhesive System Selection
Installation and Location of Post-Installed Reinforcing Bars Procedure
Specification and Detailing - Best Practice
Rebar Design Resources
Summary

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 13

ICC-ES AC308 WAS AMENDED IN 2013 TO QUALIFY


ADHESIVE ANCHOR SYSTEMS FOR POST-INSTALL REBAR

1995 2002 2006 2013

Extensive
investigations begin…

ICC-ES amends AC 308

EOTA issues TR023 Assessment of Post-Installed


Reinforcing Bar Connections

Research – University of Stuttgart,


“Structural Behavior and Design of Bonded Reinforcing Bars”
H. Speith, doctoral thesis
Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 14

7
TENSION TESTS COMPARE THE PERFORMANCE OF
POST-INSTALLED AND CAST-IN REINFORCING BARS

Comparison of bond stresses as a function of edge distance 1

1 Spieth, H., “Structural Behavior and Design of Bonded Reinforcing Bars,” doctoral thesis, University of Stuttgart

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 15

CAST-IN BARS AND QUALIFIED POST-INSTALLED REINFORCING


BARS BEHAVE THE SAME WITH SMALL COVER (~2”)

Comparison of bond stresses as a function of edge distance 1

1 Spieth, H., “Structural Behavior and Design of Bonded Reinforcing Bars,” doctoral thesis, University of Stuttgart

Splitting is the failure mode for slender elements with small concrete cover.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 16

8
HOW ARE ADHESIVE SYSTEMS QUALIFIED TO VERIFY
“SAME AS CAST-IN” REINFORCING BAR PERFORMANCE?

ICC-ES AC308 lists the full range of tests required to qualify adhesive anchor systems for
post-installed reinforcing bar applications.

• The suitability of an adhesive system for post-installed reinforcing bar applications is


dependent on many factors.

• Systems that may be appropriate for anchoring applications will not necessarily fulfill the
requirements for safe and reliable reinforcing bar installations.

AC308 Table 3.8 details the test program for evaluation and qualification.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 17

AC308 TEST PROGRAM IS EXTENSIVE

Rebar tests include:


• Service condition tests • Installation procedure verification
– Up to #8 (25M), 35d embedment • dmax , 60d embedment
• Reliability tests • Installation without air voids
– Sensitivity to: • Durability
– Hole cleaning – Resistance to alkalinity,
– Saturated concrete sulfur, corrosion
– Freeze/thaw • Seismic qualification (optional)
– Sustained loads at high temps
– Decreased installation temps
– Installation direction

Systems that may be appropriate for anchoring applications will not necessarily
fulfill the requirements for safe and reliable reinforcing bar installations.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 18

9
ICC-ES AC308 TEST FOR BOND / SPLITTING BEHAVIOR

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 19

THESE TESTS DIRECTLY COMPARE CAST-IN AND


POST-INSTALLED BAR PERFORMANCE UNDER CONDITIONS
WHERE SPLITTING IS THE LIMITING FAILURE MODE
Characteristics
Stiffness

If the adhesive is too stiff, excessive shear lag can lead


to zipper-like failure of the near edge bar.
Properties
Material

If the bond is too “soft”, relaxation of the post-installed bar


may permit excessive opening of the joint between old and
new concrete, leading to loss of shear transfer or corrosion.

Adhesives and grout which have not been properly verified


for post-installed reinforcing bar applications should not be used.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 20

10
AGENDA

Fundamental Principles of Anchor and Rebar Theory


Building Code Requirements and Acceptance Criteria for Post-Installed Rebar
Adhesive System Selection
Installation and Location of Post-Installed Reinforcing Bars Procedure
Specification and Detailing - Best Practice
Rebar Design Resources
Summary

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 21

HOW CAN YOU VERIFY THAT A PRODUCT CONFORMS WITH


THE LATEST CODE REQUIREMENTS?

EASY – look for an Evaluation Service Report (ESR) for that product.

What is an ESR?

• Product specific ESRs, which verifies code compliance*, are published by ICC-ES
based on testing performed in accordance with appropriate acceptance criteria (AC).
*ESRs do not specifically address Canadian codes but the qualification testing requirements are essentially identical in the US and Canada

ICC-ES Evaluation Reports play an important role in providing clear


evidence that products comply with codes and standards.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 22

11
ICC-ES EVALUATION REPORT CONFIRMS THAT THE SYSTEM
SELECTED IS APPROPRIATE FOR USE
A CSI Division Number
B Report Holder
C Evaluation Subject
1.0 Evaluation Scope
2.0 Uses
3.0 Description
4.0 Installation
5.0 Conditions of Use
6.0 Evidence Submitted
7.0 Identification

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 23

ICC-ES APPROVALS FOR REBAR INSTALLATION USING HIT-RE 500-SD, HIT-


HY 200 SAFESET AND HIT-RE 500 V3 SAFESET

1995 2002 2006 2013 2015

ESR-3814 issued for HIT-RE 500


V3 SafeSet rebar system
Extensive
investigations begin… ESR-3187 is updated with HIT-
HY 200 SafeSet rebar system
April 2015
Hilti gains the first rebar approval
per updated code - ESR-2322, HIT-
RE 500-SD SafeSet rebar system
ICC-ES amends AC 308

EOTA issues TR023 Assessment of Post-Installed


Reinforcing Bar Connections

Research – University of Stuttgart,


“Structural Behavior and Design of Bonded Reinforcing Bars”
H. Speith, doctoral thesis
Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 24

12
SIZE AND REQUIRED BOND LENGTH GUIDE THE TYPE OF
ADHESIVE USED

• HIT-RE 500 V3 • HIT-HY 200 w/SafeSet


w/SafeSet • Anchoring applications
• Rebar applications • Small/medium rebar
• Large rebar • Shallow holes
• Deep holes • Shorter working time
• Longer working time • Shorter cure time
• Longer cure time

Required bar embedment is based on the development length and


splice provisions of the Code – ACI 318, Chapter 12.2 or CSA A23.3 Chapter 12.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 25

FAST CURE ADHESIVE ANCHORING SYSTEM


HILTI HIT-HY 200-A SAFESET ADHESIVE
Cracked Uncracked
Concrete Concrete

Load type Static, seismic


Anchor size 3/8” – 1 1/4”
Rebar size #3 - #10 (10M-30M)
Hilti SafeSet HDB Yes
Hammer drill bit Yes
Diamond coring with
No
SafeSet Roughening Tool
Hilti HIT-Z Rod Yes ICC ESR-3187
Base material conditions Dry, Wet
Cure time (68°F/20°C) 30 mins
Work time (68°F/20°C) 7 mins

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 26

13
SLOW CURE ADHESIVE ANCHORING SYSTEM
HILTI HIT-RE 500 V3 SAFESET ADHESIVE
Cracked Uncracked
Concrete Concrete

Load type Static, seismic


Anchor size 3/8” – 1 1/4”
Rebar size #3 - #10 (10M-30M)
Hilti SafeSet HDB Yes
Hammer drill bit Yes
Diamond coring with
Yes
SafeSet Roughening Tool
Hilti HIT-Z Rod No
ICC ESR-3814
Dry, Wet, Water filled,
Base material conditions
Underwater
Cure time (68°F/20°C) 6 hrs
Work time (68°F/20°C) 20 mins

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 27

HILTI ADHESIVE ANCHORS ARE QUALIFIED FOR USE WITH


POST-INSTALLED REINFORCING BARS PER CHAPTER 12

Tension development length: ACI 318-11 12.2.3

where the confinement term (cb + Ktr)/ db shall not be


taken as greater than 2.5 and the design value of ld
shall not be less than 12 inches per 12.2.1.

Tension lap splices: ACI 318-11 12.15.1

Hilti adhesive anchors perform like cast-in reinforcing bars.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 28

14
HILTI ADHESIVE ANCHORS ARE QUALIFIED FOR USE WITH
POST-INSTALLED REINFORCING BARS PER CHAPTER 12

Tension development length: CSA A23.3-14 12.2.2

where the confinement term (dcs + Ktr) shall not be


taken as greater than 2.5 db and the design value of
ld shall not be less than 300 mm per 12.2.1.

Tension lap splices: CSA A23.3-14 12.15.1

Hilti adhesive anchors perform like cast-in reinforcing bars.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 29

AGENDA

Fundamental Principles of Anchor and Rebar Theory


Building Code Requirements and Acceptance Criteria for Post-Installed Rebar
Adhesive System Selection
Installation and Location of Post-Installed Reinforcing Bars Procedure
Specification and Detailing - Best Practice
Rebar Design Resources
Summary

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 30

15
INSTALLATION AND LOCATION OF POST-INSTALLED
REINFORCING BARS IS CRITICAL TO PERFORMANCE

1 Locate existing reinforcement and other embedded items

2 Roughen the existing concrete surface

3 Ensure adequate concrete cover

4 Select the proper drilling method

5 Ensure hole cleaning

6 Proper selection of adhesive system

7 Proper injection of the adhesive and bar installation

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 31

LOCATING EXISTING REINFORCEMENT AND ROUGHENING


THE EXISTING CONCRETE SURFACE ARE THE INITIAL STEPS

1 2

Using a hand-held scanner to locate and map Roughening a concrete surface with a combihammer
existing reinforcing prior to drilling. and bushing tool

ACI 318-11 Section 11.6.9 requires roughening to a


“full amplitude of approx. 1/4 inch.” This may be
accomplished by mechanical means (i.e. - using a
combi/bushing tool), sand-blasting, or water-blasting.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 32

16
SELECTING THE PROPER DRILLING METHOD HELP TO
ENSURE PROPER CONCRETE COVER
3

• Sufficient distance must be provided


from concrete face to facilitate
drilling without splitting and/or
spalling.

• Drilling alignment aids improve


drilling accuracy.

• ACI or CSA provisions for cover and


bar spacing should be observed.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 33

SELECTING THE PROPER DRILLING METHOD HELPS


ENSURE PROPER CONCRETE COVER
4 Drilling with a Hilti rotary-percussive drill Core drilling with a hand-held Hilti wet
equipped with Hilti SafeSet technology core drill with water-capture technology

Hilti SafeSet system greatly simplifies the installation process.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 34

17
THE BOND BETWEEN THE ADHESIVE AND CONCRETE IS
DIRECTLY INFLUENCED BY THE HOLE CLEANING.
5

It is critical that the Manufacturer Printed Installation Instructions (MPII)


are followed to ensure proper installation.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 35

EVERY PACKAGE OF ADHESIVE CONTAINS THE


MANUFACTURER PRINTED INSTALLATION INSTRUCTIONS

Note: Shown for illustrative purposes only. Reference complete manufacturer installation instructions before installing your specific anchor.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 36

18
PROPER HOLE CLEANING IS ESSENTIAL: AVAILABLE DUST
CONTROL SYSTEMS SIMPLIFY THE PROCESS
5

Traditional Installation Method

or

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 37

SELECTING THE PROPER ADHESIVE AND INJECTION


METHOD WILL HELP ENSURE CORRECT INSTALLATION
6 7

• Can the adhesive be injected and the bar installed • Available battery dispensers simplify the injection
within the gel time of the adhesive? of the adhesive into the hole.
• Is the appropriate injection equipment available, • Piston plug systems provide positive feedback to
including all necessary accessories, to ensure the operator for controlling the injection process
correct dispensing and mixing? and dramatically improves injection quality and
• Is the adhesive suitable for the concrete temp, efficiency.
moisture conditions, hole orientation and drilling
method?
• What effort is required to inject the adhesive?
Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 38

19
HOLES THAT CLEAN THEMSELVES
SafeSet Post-Installed Rebar System

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 39

MANUFACTURER TRAINING - US

Manufacturer IBC 2012 / 2015

Manufacturer Adhesive
ACI & CRSI
Anchor Installer Training Adhesive Anchor Installer
Certification program

Your name here

Hilti can help the contractor understand correct installation steps and prepare for the
Adhesive Anchor Installer Certification or manufacturer advanced training.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 40

20
MANUFACTURER TRAINING - CANADA

Manufacturer CSA A23.3-14

Manufacturer Adhesive
ACI & CRSI or Equal
Anchor Installer Training Adhesive Anchor Installer
Certification program

Your name here

Hilti can help the contractor understand correct installation steps and prepare for the
Adhesive Anchor Installer Certification or manufacturer advanced training.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 41

HILTI ADHESIVE ANCHOR PORTFOLIO WITH


POST-INSTALLED REBAR QUALIFICATION
2
HIT-HY 200
SafeSet
Fast Cure Hybrid
Concrete

HIT-RE 500 V3
SafeSet
Slow Cure Epoxy

Required bar embedment is based on the development length and


splice provisions of the Code – ACI 318 Chapter 12.2 or CSA A23.3 Chapter 12.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 42

21
AGENDA

Fundamental Principles of Anchor and Rebar Theory


Building Code Requirements and Acceptance Criteria for Post-Installed Rebar
Adhesive System Selection
Installation and Location of Post-Installed Reinforcing Bars Procedure
Specification and Detailing - Best Practice
Rebar Design Resources
Summary

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 43

CRITICAL ASPECTS OF THE DESIGN SHOULD BE CLEARLY


INDICATED IN THE CONNECTION DETAIL
Specifications and details may include:
a• Adhesive system


b Bar type and size

c• Required bar embedment


d Hole diameters and drilling method(s)

e• Preparation/roughening of existing concrete surface

•f Inviolability of existing reinforcement and embeds


g Installer training/certification requirements


h Inspection/proof loading requirements

Substitutions based on a simple specification of bond stress may not be


sufficient to ensure proper execution of the work.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 44

22
CONNECTION DETAIL EXAMPLE:
DOWELS AT NEW SHOTCRETE WALL

a
Hilti HIT-RE 500 V3 SafeSet

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 45

CONNECTION DETAIL EXAMPLE:


NEW BALCONY EXTENSION

b
f

c a
HIT-RE 500 V3 SafeSet

e HIT-RE 500 V3 SafeSet a

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 46

23
SPECIFYING WITH HILTI HIT-RE 500 V3 AND HIT-HY 200
SAFESET SYSTEMS IN THE GENERAL NOTES

a d

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 47

AGENDA

Fundamental Principles of Anchor and Rebar Theory


Building Code Requirements and Acceptance Criteria for Post-Installed Rebar
Adhesive System Selection
Installation and Location of Post-Installed Reinforcing Bars Procedure
Specification and Detailing - Best Practice
Rebar Design Resources
Summary

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 48

24
REBAR DESIGN CENTER

Product code/approval documents Continuing Education Courses and Webinars

PROFIS Rebar and PROFIS Anchor Product Submittals

Technical Data (load tables) Educational White Papers

Specification Text and CAD Details


www.hilti.com/rebar www.hilti.ca/rebar
Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 49

DESIGN MADE EASY…


1 PROFIS Rebar Software 2 Hilti Post-Installed Reinforcing
Bar Supplement

• Web-based software
• Quick reference guide for
• Design post-installed rebar
– Non-contact lap splices
connections per ACI 318
– Shear dowels
– Starter bars
• https://profisrebar.hilti.com
• Design examples

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 50

25
A NEW PUBLICATION IS AVAILABLE WHICH PROVIDES FURTHER
DETAILS INTO POST-INSTALLED REINFORCING BAR DESIGN

Download the publication in PDF format


https://www.hilti.com/technical-guides or https://www.hilti.ca/technical-guides

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 51

AGENDA

Fundamental Principles of Anchor and Rebar Theory


Building Code Requirements and Acceptance Criteria for Post-Installed Rebar
Adhesive System Selection
Installation and Location of Post-Installed Reinforcing Bars Procedure
Specification and Detailing - Best Practice
Rebar Design Resources
Summary

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 52

26
SUMMARY

• Acceptance criteria (AC308) now qualifies adhesive • Cast-in bars and qualified post-installed reinforcing
anchor systems for post-installed reinforcing bar bars behave the same with small cover (~2”).
applications.
• Qualified adhesive anchor systems can be
• The suitability of an adhesive system for post- designed like a cast-in reinforcing bar using ACI
installed reinforcing bar applications is dependent 318, Chapter 12 or CSA A23.3 Chapter 12.
on many factors.
• Installation and location of post-installed reinforcing
• Systems that may be appropriate for anchoring bars is critical to performance and should be
applications will not necessarily fulfill the appropriately detailed and specified.
requirements for safe and reliable reinforcing bar
installations.
• Assumption of reinforcing bar development is the
most fundamental distinction separating post-
installed rebar from adhesive anchors.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 53

ADDITIONAL RESOURCES:

ICC-Evaluation Service
• www.icc-es.org
Hilti Online
• www.hilti.com or www.hilti.ca

Technical manuals:
• Hilti North America Post-Installed Reinforcing Bar Guide
• Hilti North America Post-Installed Reinforcing Bar Supplement

Research papers:
“Recommended Procedures for Development and Splicing of Postinstalled Bonded
Reinforcing Bars in Concrete Structures,” ACI Structural Journal, Vol. 110, No. 3, pp.
437-447, Charney, F., Pal, K., and Silva, J. (2013).
“Structural Behavior and Design of Bonded Reinforcing Bars”, doctoral thesis,
University of Stuttgart (in German), Spieth, H. (2002).

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 54

27
ASK HILTI
Hilti engineering community
and On-Demand Education
platform

55

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 56

28
YOUR ON-DEMAND EDUCATION ENGINEERING PLATFORM

Accredited, on-demand courses for you to access 24/7 and keep


track of your earned continuing education within your personal
portal

Watch the webinar Take the quiz Earn the credits


After watching all Register and complete With 80% or higher you
chapters of a webinar, your profile to take the pass the quiz. The
you unlock the quiz quiz certificate is then stored
in your profile!

Upload all your certs (not just Hilti’s) to have them all in one
place!
Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 57

ENGINEERING COMMUNITY

Connect with engineers all over the US and Hilti experts to


solve your problem and get second opinions on tricky
challenges.

Ask a question Get expert advice Share your experience


Hilti’s Technical Service Easily search through Easily collaborate with other
Engineering team will hundreds of technical engineering professionals to gain
answer your Hilti relevant questions to find the insights and inspiration
technical questions answers you are looking for

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 58

29
UPCOMING NCSEA-ACCREDITED WEBINAR

Integrating Software into Anchor Design


Wednesday, August 9th at 11 AM CDT and Thursday, August 10th at 2 PM CDT

Register today at www.us.hilti.com/technical-webinars

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 59

QUESTIONS?
Hilti North America
 (877) 749-6337 – Technical Support Team
 HNAtechnicalservices@hilti.com
 www.us.hilti.com/engineering

Abraham Chapa
Field Engineer
Dallas-Forth Worth, TX

Dick Morgan, PE
PROFIS Software and Literature Manager
Plano, TX

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 60

30
-Conclusion of Hilti webinar-

Fundamentals of Post-installed Reinforcing Bar Design


Using Qualified Adhesive Anchor Systems
Rebar 101

Individual participants:
Individual participants will receive a certificate to the email provided during registration.
Certificates will be distributed within a week of the event.

Group participants:
Attendees participating in a group go to www.us.hilti.com/webinar-group-sign-in to
enter the team’s information. Certificates will be distributed within a week of the event.

Certificates:
One (1.0) hour credit is approved by NCSEA.

Fundamentals of Post-Installed Rebar Using Qualified Adhesive Anchor Systems 61

31

S-ar putea să vă placă și