Appendix VII Limit Tests


(No Ph. Eur. method)

Nessler Cylinders

Where the use of Nessler cylinders is prescribed in a test of the Pharmacopoeia, Nessler
cylinders complying with the following requirements should be used.

Nessler cylinders comply with British Standard 612:1966 (Specification for Nessler cylinders).
They are of clear glass with a nominal capacity of 50 mL; the overall height is about 15 cm,
the external height to the 50-mL mark 11.0 to 12.4 cm, the thickness of the wall 1.0 to 1.5 mm
and the thickness of the base 1.0 to 3.0 mm. The external heights to the 50-mL mark of
cylinders used for a test must not differ by more than 1 mm.

Tubes for Comparative Tests

(Ph. Eur. method 2.1.5)

Tubes used for comparative tests are matched tubes of colourless glass with a uniform
internal diameter. The base is transparent and flat.

A column of the liquid is examined down the vertical axis of the tube against a white
background, or if necessary, against a black background. The examination is carried out in
diffused light.

It is assumed that tubes with an internal diameter of 16 mm will be used. Tubes with a larger
internal diameter may be used instead but the volume of liquid examined must then be
increased so that the depth of liquid in the tubes is not less than where the prescribed volume
of liquid and tubes 16 mm in internal diameter are used.

Limit Test for Aluminium

(Ph. Eur. method 2.4.17)

Place the prescribed solution in a separating funnel and shake with 2 quantities, each of 20
mL, and then with one 10 mL quantity of a 5 g/L solution of hydroxyquinoline R in chloroform
R. Dilute the combined chloroform solutions to 50.0 mL with chloroform R (test solution).

Prepare a standard in the same manner using the prescribed reference solution.

Prepare a blank in the same manner using the prescribed blank solution.

Measure the intensity of the fluorescence (2.2.21) of the test solution (I1), of the standard (I2)
and of the blank (I3) using an excitant beam at 392 nm and a secondary filter with a
transmission band centred on 518 nm or a monochromator set to transmit at this wavelength.

The fluorescence (I1- I3) of the test solution is not greater than that of the standard (I2- I3).

Limit Test for Ammonium

©Crown Copyright 2012 1


(Ph. Eur. method 2.4.1)

Unless otherwise prescribed, use method A.

METHOD A

Dissolve the prescribed quantity of the substance to be examined in 14 mL of water R in a


test-tube, make alkaline if necessary by the addition of dilute sodium hydroxide solution R and
dilute to 15 mL with water R. To the solution add 0.3 mL of alkaline potassium
tetraiodomercurate solution R. Prepare a standard by mixing 10 mL of ammonium standard
solution (1 ppm NH4) R with 5 mL of water R and 0.3 mL of alkaline potassium
tetraiodomercurate solution R. Stopper the test-tubes.

After 5 min, any yellow colour in the test solution is not more intense than that in the standard.

METHOD B

In a 25 mL jar fitted with a cap, place the prescribed quantity of the finely powdered substance
to be examined and dissolve or suspend in 1 mL of water R. Add 0.30 g of heavy magnesium
oxide R. Close immediately after placing a piece of silver manganese paper R 5 mm square,
wetted with a few drops of water R, under the polyethylene cap. Swirl, avoiding projections of
liquid, and allow to stand at 40 °C for 30 min. If the silver manganese paper shows a grey
colour, it is not more intense than that of a standard prepared at the same time and in the
same manner using the prescribed volume of ammonium standard solution (1 ppm NH4) R, 1
mL of water R and 0.30 g of heavy magnesium oxide R.

Limit Test for Arsenic

(Ph. Eur. method 2.4.2)

METHOD A

The apparatus (see Figure 2.4.2.-1) consists of a 100 mL conical flask closed with a ground-
glass stopper through which passes a glass tube about 200 mm long and of internal diameter
5 mm. The lower part of the tube is drawn to an internal diameter of 1.0 mm, and 15 mm from
its tip is a lateral orifice 2 mm to 3 mm in diameter. When the tube is in position in the stopper,
the lateral orifice should be at least 3 mm below the lower surface of the stopper. The upper
end of the tube has a perfectly flat, ground surface at right angles to the axis of the tube. A
second glass tube of the same internal diameter and 30 mm long, with a similar flat ground
surface, is placed in contact with the first, and is held in position by two spiral springs. Into the
lower tube insert 50 mg to 60 mg of lead acetate cotton R, loosely packed, or a small plug of
cotton and a rolled piece of lead acetate paper R weighing 50 mg to 60 mg. Between the flat
surfaces of the tubes place a disc or a small square of mercuric bromide paper R large
enough to cover the orifice of the tube (15 mm × 15 mm).

In the conical flask dissolve the prescribed quantity of the substance to be examined in 25 mL
of water R, or in the case of a solution adjust the prescribed volume to 25 mL with water R.
Add 15 mL of hydrochloric acid R, 0.1 mL of stannous chloride solution R and 5 mL of
potassium iodide solution R, allow to stand for 15 min and introduce 5 g of activated zinc R.
Assemble the two parts of the apparatus immediately and immerse the flask in a bath of water
at a temperature such that a uniform evolution of gas is maintained. Prepare a standard in the
same manner, using 1 mL of arsenic standard solution (1 ppm As) R, diluted to 25 mL with
water R.

©Crown Copyright 2012 2


After not less than 2 h the stain produced on the mercuric bromide paper in the test is not
more intense than that in the standard.

METHOD B

Introduce the prescribed quantity of the substance to be examined into a test-tube containing
4 mL of hydrochloric acid R and about 5 mg of potassium iodide R and add 3 mL of
hypophosphorous reagent R. Heat the mixture on a water-bath for 15 min, shaking
occasionally. Prepare a standard in the same manner, using 0.5 mL of arsenic standard
solution (10 ppm As) R.

After heating on the water-bath, any colour in the test solution is not more intense than that in
the standard.

©Crown Copyright 2012 3


Limit Test for Calcium

(Ph. Eur. method 2.4.3)

All solutions used for this test should be prepared with distilled water R.

To 0.2 mL of alcoholic calcium standard solution (100 ppm Ca) R, add 1 mL of ammonium
oxalate solution R. After 1 min, add a mixture of 1 mL of dilute acetic acid R and 15 mL of a
solution containing the prescribed quantity of the substance to be examined and shake.
Prepare a standard in the same manner using a mixture of 10 mL of aqueous calcium
standard solution (10 ppm Ca) R, 1 mL of dilute acetic acid R and 5 mL of distilled water R.

After 15 min, any opalescence in the test solution is not more intense than that in the
standard.

Limit Test for Chlorides

(Ph. Eur. method 2.4.4)

To 15 mL of the prescribed solution add 1 mL of dilute nitric acid R and pour the mixture as a
single addition into a test-tube containing 1 mL of silver nitrate solution R2. Prepare a
standard in the same manner using 10 mL of chloride standard solution (5 ppm Cl) R and 5
mL of water R. Examine the tubes laterally against a black background.

After standing for 5 min protected from light, any opalescence in the test solution is not more
intense than that in the standard.

Limit Test for Fluorides

(Ph. Eur. method 2.4.5)

©Crown Copyright 2012 4


©Crown Copyright 2012 5
Introduce into the inner tube of the apparatus (see Figure 2.4.5.-1) the prescribed quantity of
the substance to be examined, 0.1 g of acid-washed sand R and 20 mL of a mixture of equal
volumes of sulfuric acid R and water R. Heat the jacket containing tetrachloroethane R
maintained at its boiling point (146 °C). Heat the steam generator and distil, collecting the
distillate in a 100 mL volumetric flask containing 0.3 mL of 0.1 M sodium hydroxide and 0.1 mL
of phenolphthalein solution R. Maintain a constant volume (20 mL) in the tube during
distillation and ensure that the distillate remains alkaline, adding 0.1 M sodium hydroxide if
necessary. Dilute the distillate to 100 mL with water R (test solution). Prepare a standard in
the same manner by distillation, using 5 mL of fluoride standard solution (10 ppm F) R instead
of the substance to be examined. Into two glass-stoppered cylinders introduce 20 mL of the
test solution and 20 mL of the standard and 5 mL of aminomethylalizarindiacetic acid reagent
R.

After 20 min, any blue colour in the test solution (originally red) is not more intense than that in
the standard.

Limit Test for Heavy Metals

(Ph. Eur. method 2.4.8)

The methods described below require the use of thioacetamide reagent R. As an alternative,
sodium sulfide solution R1 (0.1 mL) is usually suitable. Since tests prescribed in monographs
have been developed using thioacetamide reagent R, if sodium sulfide solution R1 is used
instead, it is necessary to include also for methods A, B and H a monitor solution, prepared
from the quantity of the substance to be examined prescribed for the test, to which has been
added the volume of lead standard solution prescribed for preparation of the reference
solution. The test is invalid if the monitor solution is not at least as intense as the reference
solution.

METHOD A

Test solution  12 mL of the prescribed aqueous solution of the substance to be examined.

Reference solution (standard)  A mixture of 10 mL of lead standard solution (1 ppm Pb) R


or lead standard solution (2 ppm Pb) R, as prescribed, and 2 mL of the prescribed aqueous
solution of the substance to be examined.

Blank solution  A mixture of 10 mL of water R and 2 mL of the prescribed aqueous solution


of the substance to be examined.

To each solution, add 2 mL of buffer solution pH 3.5 R. Mix and add to 1.2 mL of
thioacetamide reagent R. Mix immediately. Examine the solutions after 2 min.

System suitability  The reference solution shows a slight brown colour compared to the

©Crown Copyright 2012 6


blank solution.

Result  Any brown colour in the test solution is not more intense than that in the reference
solution.

If the result is difficult to judge, filter the solutions through a suitable membrane filter (nominal
pore size 0.45 µm). Carry out the filtration slowly and uniformly, applying moderate and
constant pressure to the piston. Compare the spots on the filters obtained with the different
solutions.

METHOD B

Test solution  12 mL of the prescribed solution of the substance to be examined prepared


using an organic solvent containing a minimum percentage of water (for example, dioxan
containing 15 per cent of water or acetone containing 15 per cent of water).

Reference solution (standard)  A mixture of 10 mL of lead standard solution (1 or 2 ppm


Pb), as prescribed, and 2 mL of the prescribed solution of the substance to be examined in an
organic solvent. Prepare the lead standard solution (1 or 2 ppm Pb) by dilution of lead
standard solution (100 ppm Pb) R with the solvent used for the substance to be examined.

Blank solution  A mixture of 10 mL of the solvent used for the substance to be examined
and 2 mL of the prescribed solution of the substance to be examined in an organic solvent.

To each solution, add 2 mL of buffer solution pH 3.5 R. Mix and add to 1.2 mL of
thioacetamide reagent R. Mix immediately. Examine the solutions after 2 min.

System suitability  The reference solution shows a slight brown colour compared to the
blank solution.

Result  Any brown colour in the test solution is not more intense than that in the reference
solution.

If the result is difficult to judge, filter the solutions through a suitable membrane filter (nominal
pore size 0.45 µm). Carry out the filtration slowly and uniformly, applying moderate and
constant pressure to the piston. Compare the spots on the filters obtained with the different
solutions.

METHOD C

Test solution  Place the prescribed quantity (not more than 2 g) of the substance to be
examined in a silica crucible with 4 mL of a 250 g/L solution of magnesium sulfate R in dilute
sulfuric acid R. Mix using a fine glass rod. Heat cautiously. If the mixture is liquid, evaporate
gently to dryness on a water-bath. Progressively heat to ignition and continue heating until an
almost white or at most greyish residue is obtained. Carry out the ignition at a temperature not
exceeding 800 °C. Allow to cool. Moisten the residue with a few drops of dilute sulfuric acid R.
Evaporate, ignite again and allow to cool. The total period of ignition must not exceed 2 h.
Take up the residue in 2 quantities, each of 5 mL, of dilute hydrochloric acid R. Add 0.1 mL of

©Crown Copyright 2012 7


phenolphthalein solution R, then concentrated ammonia R until a pink colour is obtained.
Cool, add glacial acetic acid R until the solution is decolorised and add 0.5 mL in excess.
Filter if necessary and wash the filter. Dilute to 20 mL with water R.

Reference solution (standard)  Prepare as described for the test solution, using the
prescribed volume of lead standard solution (10 ppm Pb) R instead of the substance to be
examined. To 10 mL of the solution obtained add 2 mL of the test solution.

Monitor solution  Prepare as described for the test solution, adding to the substance to be
examined the volume of lead standard solution (10 ppm Pb) R prescribed for preparation of
the reference solution. To 10 mL of the solution obtained add 2 mL of the test solution.

Blank solution  A mixture of 10 mL of water R and 2 mL of the test solution.

To 12 mL of each solution, add 2 mL of buffer solution pH 3.5 R. Mix and add to 1.2 mL of
thioacetamide reagent R. Mix immediately. Examine the solutions after 2 min.

System suitability 

 — the reference solution shows a slight brown colour compared to the blank solution,

 — the monitor solution is at least as intense as the reference solution.

Result  Any brown colour in the test solution is not more intense than that in the reference
solution.

If the result is difficult to judge, filter the solutions through a suitable membrane filter (nominal
pore size 0.45 µm). Carry out the filtration slowly and uniformly, applying moderate and
constant pressure to the piston. Compare the spots on the filters obtained with the different
solutions.

METHOD D

Test solution  In a silica crucible, mix thoroughly the prescribed quantity of the substance to
be examined with 0.5 g of magnesium oxide R1. Ignite to dull redness until a homogeneous
white or greyish-white mass is obtained. If after 30 min of ignition the mixture remains
coloured, allow to cool, mix using a fine glass rod and repeat the ignition. If necessary repeat
the operation. Heat at 800 °C for about 1 h. Take up the residue in 2 quantities, each of 5 mL,
of a mixture of equal volumes of hydrochloric acid R1 and water R. Add 0.1 mL of
phenolphthalein solution R and then concentrated ammonia R until a pink colour is obtained.
Cool, add glacial acetic acid R until the solution is decolorised and add 0.5 mL in excess.
Filter if necessary and wash the filter. Dilute to 20 mL with water R.

Reference solution (standard)  Prepare as described for the test solution using the
prescribed volume of lead standard solution (10 ppm Pb) R instead of the substance to be
examined and drying in an oven at 100-105 °C. To 10 mL of the solution obtained add 2 mL of
the test solution.

©Crown Copyright 2012 8


Monitor solution  Prepare as described for the test solution, adding to the substance to be
examined the volume of lead standard solution (10 ppm Pb) R prescribed for preparation of
the reference solution and drying in an oven at 100-105 °C. To 10 mL of the solution obtained
add 2 mL of the test solution.

Blank solution  A mixture of 10 mL of water R and 2 mL of the test solution.

To 12 mL of each solution, add 2 mL of buffer solution pH 3.5 R. Mix and add to 1.2 mL of
thioacetamide reagent R. Mix immediately. Examine the solutions after 2 min.

System suitability  

 — the reference solution shows a slight brown colour compared to the blank solution,

 — the monitor solution is at least as intense as the reference solution.

Result  Any brown colour in the test solution is not more intense than that in the reference
solution.

If the result is difficult to judge, filter the solutions through a suitable membrane filter (nominal
pore size 0.45 µm). Carry out the filtration slowly and uniformly, applying moderate and
constant pressure to the piston. Compare the spots on the filters obtained with the different
solutions.

METHOD E

Test solution  Dissolve the prescribed quantity of the substance to be examined in 30 mL of


water R or the prescribed volume.

©Crown Copyright 2012 9


Reference solution (standard)  Unless otherwise prescribed, dilute the prescribed volume
of lead standard solution (1 ppm Pb) R to the same volume as the test solution.

Prepare the filtration apparatus by adapting the barrel of a 50 mL syringe without its piston to
a support containing, on the plate, a membrane filter (nominal pore size 3 µm) and above it a
prefilter (Figure 2.4.8.-1).

Transfer the test solution into the syringe barrel, put the piston in place and then apply an
even pressure on it until the whole of the liquid has been filtered. In opening the support and
removing the prefilter, check that the membrane filter remains uncontaminated with impurities.
If this is not the case replace it with another membrane filter and repeat the operation under
the same conditions.

To the prefiltrate or to the prescribed volume of the prefiltrate add 2 mL of buffer solution pH
3.5 R. Mix and add to 1.2 mL of thioacetamide reagent R. Mix immediately and allow to stand
for 10 min and again filter as described above, but inverting the order of the filters, the liquid
passing first through the membrane filter before passing through the prefilter (Figure 2.4.8.-1).
The filtration must be carried out slowly and uniformly by applying moderate and constant
pressure to the piston of the syringe. After complete filtration, open the support, remove the
membrane filter, and dry using filter paper.

In parallel, treat the reference solution in the same manner as the test solution.

Result  The colour of the spot obtained with the test solution is not more intense than that

©Crown Copyright 2012 10


obtained with the reference solution.

METHOD F

Test solution  Place the prescribed quantity or volume of the substance to be examined in a
clean, dry, 100 mL long-necked combustion flask (a 300 mL flask may be used if the reaction
foams excessively). Clamp the flask at an angle of 45°. If the substance to be examined is a
solid, add a sufficient volume of a mixture of 8 mL of sulfuric acid R and 10 mL of nitric acid R
to moisten the substance thoroughly; if the substance to be examined is a liquid, add a few
millilitres of a mixture of 8 mL of sulfuric acid R and 10 mL of nitric acid R. Warm gently until
the reaction commences, allow the reaction to subside and add additional portions of the
same acid mixture, heating after each addition, until a total of 18 mL of the acid mixture has
been added. Increase the amount of heat and boil gently until the solution darkens. Cool, add
2 mL of nitric acid R and heat again until the solution darkens. Continue the heating, followed
by the addition of nitric acid R until no further darkening occurs, then heat strongly until dense,
white fumes are produced. Cool, cautiously add 5 mL of water R, boil gently until dense, white
fumes are produced and continue heating to reduce to 2-3 mL. Cool, cautiously add 5 mL of
water R and examine the colour of the solution. If the colour is yellow, cautiously add 1 mL of
strong hydrogen peroxide solution R and again evaporate until dense, white fumes are
produced and reduce to a volume of 2-3 mL. If the solution is still yellow in colour, repeat the
addition of 5 mL of water R and 1 mL of strong hydrogen peroxide solution R until the solution
is colourless. Cool, dilute cautiously with water R and rinse into a 50 mL colour comparison
tube, ensuring that the total volume does not exceed 25 mL. Adjust the solution to pH 3.0-4.0,
using short range pH indicator paper as external indicator, with concentrated ammonia R1
(dilute ammonia R1 may be used, if desired, as the specified range is approached), dilute with
water R to 40 mL and mix. Add 2 mL of buffer solution pH 3.5 R. Mix and add to 1.2 mL of
thioacetamide reagent R. Mix immediately. Dilute to 50 mL with water R and mix.

Reference solution (standard)  Prepare at the same time and in the same manner as the
test solution, using the prescribed volume of lead standard solution (10 ppm Pb) R.

Monitor solution  Prepare as described for the test solution, adding to the substance to be
examined the volume of lead standard solution (10 ppm Pb) R prescribed for the preparation
of the reference solution.

Blank solution  Prepare as described for the test solution, omitting the substance to be
examined.

Examine the solutions vertically against a white background after 2 min.

System suitability 

 — the reference solution shows a brown colour compared to the blank solution,

 — the monitor solution is at least as intense as the reference solution.

Result  Any brown colour in the test solution is not more intense than that in the reference
solution.

©Crown Copyright 2012 11


If the result is difficult to judge, filter the solutions through a suitable membrane filter (nominal
pore size 0.45 µm). Carry out the filtration slowly and uniformly, applying moderate and
constant pressure to the piston. Compare the spots on the filters obtained with the different
solutions.

METHOD G

CAUTION: when using high-pressure digestion vessels the safety precautions and operating
instructions given by the manufacturer must be followed. The digestion cycles have to be
elaborated depending on the type of microwave oven to be used (for example, energy-
controlled microwave ovens, temperature-controlled microwave ovens or high-pressure
ovens). The cycle must conform to the manufacturer's instructions. The digestion cycle is
suitable if a clear solution is obtained.

Test solution  Place the prescribed amount of the substance to be examined (not more
than 0.5 g) in a suitable, clean beaker. Add successively 2.7 mL of sulfuric acid R, 3.3 mL of
nitric acid R and 2.0 mL of strong hydrogen peroxide solution R using a magnetic stirrer. Allow
the substance to react with a reagent before adding the next one. Transfer the mixture to a dry
high-pressure-resistant digestion vessel (fluoropolymer or quartz glass).

Reference solution (standard ) Prepare as described for the test solution, using the
prescribed volume of lead standard solution (10 ppm Pb) R instead of the substance to be
examined.

Monitor solution  Prepare as prescribed for the test solution, adding to the substance to be
examined the volume of lead standard solution (10 ppm Pb) R prescribed for the preparation
of the reference solution.

Blank solution  Prepare as described for the test solution, omitting the substance to be
examined.

Close the vessels and place in a laboratory microwave oven. Digest using a sequence of 2
separate suitable programmes. Design the programmes in several steps in order to control the
reaction, monitoring pressure, temperature or energy depending on the type of microwave
oven available. After the first programme allow the digestion vessels to cool before opening.
Add to each vessel 2.0 mL of strong hydrogen peroxide solution R and digest using the
second programme. After the second programme allow the digestion vessels to cool before
opening. If necessary to obtain a clear solution, repeat the addition of strong hydrogen
peroxide solution R and the second digestion programme.

Cool, dilute cautiously with water R and rinse into a flask, ensuring that the total volume does
not exceed 25 mL.

Using short-range pH indicator paper as external indicator, adjust the solutions to pH 3.0-4.0
with concentrated ammonia R1 (dilute ammonia R1 may be used as the specified range is
approached). To avoid heating of the solutions use an ice-bath and a magnetic stirrer. Dilute
to 40 mL with water R and mix. Add 2 mL of buffer solution pH 3.5 R. Mix and add to 1.2 mL
of thioacetamide reagent R. Mix immediately. Dilute to 50 mL with water R, mix and allow to
stand for 2 min.

©Crown Copyright 2012 12


Filter the solutions through a suitable membrane filter (nominal pore size 0.45 µm). Carry out
the filtration slowly and uniformly, applying moderate and constant pressure to the piston.
Compare the spots on the filters obtained with the different solutions.

System suitability 

 — the spot obtained with the reference solution shows a brown colour compared to the spot
obtained with the blank solution,

 — the spot obtained with the monitor solution is at least as intense as the spot obtained with
the reference solution.

Result  The brown colour of the spot obtained with the test solution is not more intense than
that of the spot obtained with the reference solution.

METHOD H

Test solution  Dissolve the prescribed quantity of the substance to be examined in 20 mL of


the solvent or solvent mixture prescribed.

Reference solution  Dilute the prescribed volume of lead standard solution (10 ppm Pb) R
to 20 mL with the solvent or solvent mixture prescribed.

Blank solution  20 mL of the solvent or solvent mixture prescribed.

To each solution, add 2 mL of buffer solution pH 3.5 R. Mix. (In some cases precipitation
occurs, in which case the specific monograph would describe re-dissolution in a defined
volume of a given solvent.) Add to 1.2 mL of thioacetamide reagent R. Mix immediately and
allow to stand for 2 min. Filter the solutions through a suitable membrane filter (nominal pore
size 0.45 µm). Compare the spots on the filters obtained with the different solutions.

System suitability  The spot obtained with the reference solution shows a brownish-black
colour compared to the spot obtained with the blank solution.

Result  The brownish-black colour of the spot obtained with the test solution is not more
intense than that of the spot obtained with the reference solution.

Limit Test for Iron

(Ph. Eur. method 2.4.9)

Dissolve the prescribed quantity of the substance to be examined in water R and dilute to 10
mL with the same solvent or use 10 mL of the prescribed solution. Add 2 mL of a 200 g/L
solution of citric acid R and 0.1 mL of thioglycollic acid R. Mix, make alkaline with ammonia R
and dilute to 20 mL with water R. Prepare a standard in the same manner, using 10 mL of iron
standard solution (1 ppm Fe) R.

After 5 min, any pink colour in the test solution is not more intense than that in the standard.

©Crown Copyright 2012 13


Limit Test for Lead in Sugars

(Ph. Eur. method 2.4.10)

Determine the lead by atomic absorption spectrometry (2.2.23, Method II).

Test solution  Dissolve 20.0 g of the substance to be examined in a mixture of equal


volumes of dilute acetic acid R and water R and dilute to 100.0 mL with the same mixture of
solvents. Add 2.0 mL of a clear 10 g/L solution of ammonium pyrrolidinedithiocarbamate R
and 10.0 mL of methyl isobutyl ketone R and then shake for 30 s protected from bright light.
Allow the layers to separate and use the methyl isobutyl ketone layer.

Reference solutions . Prepare 3 reference solutions in the same manner as the test
solution but adding 0.5 mL, 1.0 mL and 1.5 mL respectively of lead standard solution (10 ppm
Pb) R in addition to the 20.0 g of the substance to be examined.

Set the zero of the instrument using methyl isobutyl ketone R treated as described for the test
solution without the substance to be examined. Measure the absorbance at 283.3 nm using a
lead hollow-cathode lamp as source of radiation and an air-acetylene flame.

The substance to be examined contains not more than 0.5 ppm of lead, unless otherwise
prescribed.

Limit Test for Magnesium

(Ph. Eur. method 2.4.6)

To 10 mL of the prescribed solution add 0.1 g of disodium tetraborate R. Adjust the solution, if
necessary, to pH 8.8 to pH 9.2 using dilute hydrochloric acid R or dilute sodium hydroxide
solution R. Shake with 2 quantities, each of 5 mL, of a 1 g/L solution of hydroxyquinoline R in
chloroform R, for 1 min each time. Allow to stand. Separate and discard the organic layer. To
the aqueous solution add 0.4 mL of butylamine R and 0.1 mL of triethanolamine R. Adjust the
solution, if necessary, to pH 10.5 to pH 11.5. Add 4 mL of the solution of hydroxyquinoline in
chloroform, shake for 1 min, allow to stand and separate. Use the lower layer for comparison.
Prepare a standard in the same manner using a mixture of 1 mL of magnesium standard
solution (10 ppm Mg) R and 9 mL of water R.

Any colour in the solution obtained from the substance to be examined is not more intense
than that in the standard.

Limit Test for Magnesium and Alkaline-earth Metals

(Ph. Eur. method 2.4.7)

To 200 mL of water R add 0.1 g of hydroxylamine hydrochloride R, 10 mL of ammonium


chloride buffer solution pH 10.0 R, 1 mL of 0.1 M zinc sulfate and about 15 mg of mordant
black 11 triturate R. Heat to about 40 °C. Titrate with 0.01 M sodium edetate until the violet
colour changes to full blue. To the solution add the prescribed quantity of the substance to be
examined dissolved in 100 mL of water R or use the prescribed solution. If the colour of the
solution changes to violet, titrate with 0.01 M sodium edetate until the full blue colour is again
obtained.

©Crown Copyright 2012 14


The volume of 0.01 M sodium edetate used in the second titration does not exceed the
prescribed quantity.

Limit Test for Heavy Metals in Herbal Drugs and Fatty Oils

(Ph. Eur. method 2.4.27)

Examine by atomic absorption spectrometry (2.2.23).

CAUTION: when using closed high-pressure digestion vessels and microwave laboratory
equipment, be familiar with the safety and operating instructions given by the manufacturer.

Apparatus

The apparatus typically consists of the following:

 — as digestion flasks, polytetrafluoroethylene flasks with a volume of about 120 mL, fitted
with an airtight closure, a valve to adjust the pressure inside the container and a
polytetrafluoroethylene tube to allow release of gas,

 — a system to make flasks airtight, using the same torsional force for each of them,

 — a microwave oven, with a magnetron frequency of 2450 MHz, with a selectable output
from 0 to 630 ± 70 W in 1 per cent increments, a programmable digital computer, a
polytetrafluoroethylene-coated microwave cavity with a variable speed exhaust fan, a
rotating turntable drive system and exhaust tubing to vent fumes,

 — an atomic absorption spectrometer, equipped with hollow-cathode lamps as source of


radiation and a deuterium lamp as background corrector; the system is fitted with:

 (a) a graphite furnace as atomisation device for cadmium, copper, iron, lead, nickel and
zinc.

 (b) an automated continuous-flow hydride vapour generation system for arsenic and
mercury.

Method

In case alternative apparatus is used, an adjustment of the instrument parameters may be


necessary.

Clean all the glassware and laboratory equipment with a 10 g/L solution of nitric acid R before
use.

Test solution  In a digestion flask place the prescribed quantity of the substance to be
examined (about 0.50 g of powdered drug (1400) (2.9.12) or 0.50 g of fatty oil). Add 6 mL of
heavy metal-free nitric acid R and 4 mL of heavy metal-free hydrochloric acid R. Make the
flask airtight.

Place the digestion flasks in the microwave oven. Carry out the digestion in 3 steps according
to the following programme, used for 7 flasks each containing the test solution: 80 per cent
power for 15 min, 100 per cent power for 5 min, 80 per cent power for 20 min.

©Crown Copyright 2012 15


At the end of the cycle allow the flasks to cool in air and to each add 4 mL of heavy metal-free
sulfuric acid R. Repeat the digestion programme. After cooling in air, open each digestion
flask and introduce the clear, colourless solution obtained into a 50 mL volumetric flask. Rinse
each digestion flask with 2 quantities, each of 15 mL, of water R and collect the rinsings in the
volumetric flask. Add 1.0 mL of a 10 g/L solution of magnesium nitrate R and 1.0 mL of a 100
g/L solution of ammonium dihydrogen phosphate R and dilute to 50.0 mL with water R.

Blank solution  Mix 6 mL of heavy metal-free nitric acid R and 4 mL of heavy metal-free
hydrochloric acid R in a digestion flask. Carry out the digestion in the same manner as for the
test solution.

CADMIUM, COPPER, IRON, LEAD, NICKEL AND ZINC

Measure the content of cadmium, copper, iron, lead, nickel and zinc by the standard additions
method (2.2.23, Method II), using reference solutions of each heavy metal and the
instrumental parameters described in Table 2.4.27.-1.

The absorbance value of the blank solution is automatically subtracted from the value
obtained with the test solution.

ARSENIC AND MERCURY

Measure the content of arsenic and mercury in comparison with the reference solutions of
arsenic or mercury at a known concentration by direct calibration (2.2.23, Method I) using an
automated continuous-flow hydride vapour generation system.

The absorbance value of the blank solution is automatically subtracted from the value
obtained with the test solution.

ARSENIC

©Crown Copyright 2012 16


Sample solution  To 19.0 mL of the test solution or of the blank solution as prescribed
above, add 1 mL of a 200 g/L solution of potassium iodide R. Allow the test solution to stand
at room temperature for about 50 min or at 70 °C for about 4 min.

Acid reagent  Heavy metal-free hydrochloric acid R.

Reducing reagent  A 6 g/L solution of sodium tetrahydroborate R in a 5 g/L solution of


sodium hydroxide R.

The instrumental parameters in Table 2.4.27.-2 may be used.

MERCURY

Sample solution  Test solution or blank solution, as prescribed above.

Acid reagent  A 515 g/L solution of heavy metal-free hydrochloric acid R.

Reducing reagent  A 10 g/L solution of stannous chloride R in dilute heavy metal-free


hydrochloric acid R.

The instrumental parameters in Table 2.4.27.-2 may be used.

Limit Test for Nickel in Polyols

(Ph. Eur. method 2.4.15)

©Crown Copyright 2012 17


Determine the nickel by atomic absorption spectrometry (2.2.23, Method II).

Test solution  Dissolve 20.0 g of the substance to be examined in a mixture of equal


volumes of dilute acetic acid R and water R and dilute to 100.0 mL with the same mixture of
solvents. Add 2.0 mL of a saturated solution of ammonium pyrrolidinedithiocarbamate R
(about 10 g/L) and 10.0 mL of methyl isobutyl ketone R and then shake for 30 s protected
from bright light. Allow the layers to separate and use the methyl isobutyl ketone layer.

Reference solutions . Prepare 3 reference solutions in the same manner as the test
solution but adding 0.5 mL, 1.0 mL and 1.5 mL respectively of nickel standard solution (10
ppm Ni) R in addition to the 20.0 g of the substance to be examined.

Set the zero of the instrument using methyl isobutyl ketone R treated as described for
preparation of the test solution omitting the substance to be examined. Measure the
absorbance at 232.0 nm using a nickel hollow-cathode lamp as source of radiation and an air-
acetylene flame.

The substance to be examined contains not more than 1 ppm of nickel, unless otherwise
prescribed.

Limit Test for Phosphates

(Ph. Eur. method 2.4.11)

To 100 mL of the solution prepared and, if necessary, neutralised as prescribed add 4 mL of


sulfomolybdic reagent R3. Shake and add 0.1 mL of stannous chloride solution R1. Prepare a
standard in the same manner using 2 mL of phosphate standard solution (5 ppm PO4) R and
98 mL of water R. After 10 min, compare the colours using 20 mL of each solution.

Any colour in the test solution is not more intense than that in the standard.

Limit Test for Potassium

(Ph. Eur. method 2.4.12)

To 10 mL of the prescribed solution add 2 mL of a freshly prepared 10 g/L solution of sodium


tetraphenylborate R. Prepare a standard in the same manner using a mixture of 5 mL of
potassium standard solution (20 ppm K) R and 5 mL of water R.

After 5 min, any opalescence in the test solution is not more intense than that in the standard.

Limit Test for Sulfates

(Ph. Eur. method 2.4.13)

All solutions used for this test must be prepared with distilled water R.

Add 3 mL of a 250 g/L solution of barium chloride R to 4.5 mL of sulfate standard solution (10
ppm SO4) R1. Shake and allow to stand for 1 min. To 2.5 mL of this suspension, add 15 mL of
the solution to be examined and 0.5 mL of acetic acid R. Prepare a standard in the same
manner using 15 mL of sulfate standard solution (10 ppm SO4) R instead of the solution to be

©Crown Copyright 2012 18


examined.

After 5 min, any opalescence in the test solution is not more intense than that in the standard.

©Crown Copyright 2012 19