Sunteți pe pagina 1din 4

1 Load calculation:-

Live load = 360.000 Kg/m2

Self weight of green


0.25*2600 = 650 Kg/m2
concrete for deck slab=

Shuttering plates and other members = 150 Kg/m2

Total 360.000+ 650+ 150 = 1160.00 Kg/m2

Max.Spacing of frame to support shuttering = 1.20 m

Load on ISMC per RM= 1160.00*1.20 = 1392.00 Kg/m

2 Welding length required for cleat angles (ISA 75x75x8) to support ISMC200 beams:-

Support Reaction from staad analysis = 1920.00 Kg

Per Cm strength of 6mm


0.707*6/10*1000 = 424.20 Kg/Cm
thick fillet weld=

Weld length required= 1920.00/424.20 = 4.53 cm

<4x7.5cm, henec safe

3 Connection details of bracket in cantilever portion:-

From staad analysis of brackets, max, support reaction = 1760.00 kg (Vertical)

= 2760.00 kg (Horizontal)
Resultant= SQRT(1760.00^2+2760.00^2) = 3273.41 Kg

Weld length required= 3273.41/424.20 = 7.72 cm

<2x7.5cm, henec safe

Design of Bolts

No of bolts per connection = 2.00

From staad analysis of brackets, max, support reaction = 1760.00 kg (Vertical)

= 2760.00 kg (Horizontal)

Per Bolt forces:-

In vertical direction= 1760.00/2 = 880.00 Kg

In horizontaldirection= 2760.00/2 = 1380.00 Kg

Resultant= SQRT(880.00^2+1380.00^2) = 1636.70 Kg

Dia. Of bolts = 1.60 Cm

Shear stress= 1636.70/0.785/1.60^2 = 814.44 Kg/cm2

<1000 Kg/cm2, henec safe

Hence use, 75x50mmx10mm M/s plate to be welded with web of girders.

Designed weld length at joints

Max force = 2.76 Tonnes

Min. weld length


= 2.76*1000/424.20 = 6.51 Cm
req.
4 Design of triangulated securing frame (ISMC 150)

Total weight of the girder = 25 Tonnes

Length of the girder = 31.28 m

Width of bottom flange = 0.8 m

Depth of the Girder = 1.705 m

Wind load = 240 Kg/m2

Total wind load= 31.28* 1.705* 240/1000 = 12.800 Tonnes

Total wind load at each


12.800/2 = 6.40 Tonnes
end=

Load resisted by self


.8/2* 25/2 = 5 Tonnes
weight of girder=

Capacity of ISMC 150 triangulated frame (refer staad


= 7.4 Tonnes
output)

Total capacity including self


7.4+ 5 = 12.4 Tonnes
weight resistance=

Capacity against
unpredictable accidental 12.4- 5 = 7.4 Tonnes
load=
Design of fixing bolts for triangulated securing frame (ISMC 150):-

Dia. Of bolt = 32 mm

Permissible shear stress = 100 N/mm2

Permissible tensile stress = 120 N/mm2

No of bolts = 2

Spacing of bolts = 606 mm

Max. horizontal reaction (refer staad output) = 4.33 Tonnes

Max. uplift/compr. reaction (refer staad output) = 9.55 Tonnes

Capacity of bolt to
= 0.785* 32^2* 100/10000 = 8.04 Tonnes
resist shear force

>4.33 Tonnes, hence safe.

Capacity of bolt to
= 0.785* 32^2* 120/10000 = 9.65 Tonnes
resist uplift

>9.55 Tonnes, hence safe.

Design for embedment length of bolts:-

Permissible bond
= 1.2 N/mm2
stress
Ebedment length
= 9.55*10000/(3.14* 32* 1.2) = 792.03 mm
required
<800mm (Provided), hence safe.

Designed weld length at joints

Max force = 10.00 Tonnes

Min. weld length


= 10.00*1000/424.20 = 23.57 Cm
req.