Double-action door hinges


Double-Action door hinge  TENSOR

CONVENIENCE – PRECISION – TENSOR



There are many arguments in The TENSOR concept sets a Excellent returns from And it also conceals to the tech-
favour of installing a toughened new standard in this regard – every angle nical core of the system – the
glass door – as many as there whether for new installations or Viewed “superficially”, the simple and high-precision zero-
are applications and functional refurbishments. TENSOR ­TENSOR design exhibits a position adjustment mechanism.
possibilities. Double-action ­double-action door hinges can slightly convex, curved form. This is an essential feature for
doors offer particular conveni- be fixed directly to the masonry ­Also attractively conspicuous is ensuring the effective and effi-
ence. And all the more so where or to a non-rebated frame. In the inlay of the DORMA brand, cient closing of a double-action
the door is returned to the the case of “glass-to-glass” harmoniously integrated within door.
­desired closed position by the model, the double-action door is the satin-finished aluminium
action of the hinges alone – hung from a fixed toughened hinge components. The emblem At 90°, the TENSOR system
without any need for a recessed glass side screen. may be selected to match or to holds the door firmly and
floor spring or an overhead door contrast with the hinge finish – securely in position. Once
closer cluttering the top edge of three inlays of different colours pushed in the closing direction,
the glass panel. are provided with each set. The the spring mechanism of the
inlay serves as a mechanical TENSOR fitting takes over,
stop for the hinge, thus protect- operating from an angle of 80°.
ing the surface of the fixed The door closes quickly and
hinge section against damage securely. And even at an opening
when the door is opened to 90°. angle of 2°, the torque of 10 Nm
created is sufficient to keep the
door conveniently in its closed
position.

2 DORMA
Double-Action door hinge  TENSOR

Zero position adjustable

Maximum torque of 12 Nm is
reached; at just 2°, the torque
of 10 Nm is sufficient in order
to conveniently keep the door in
its closed position.

TENSOR
Activation of the
closing function TÜV-tested/third-party verifi­
cation withrespect to quality
Securely held in and the production process.
its open position Confirmed completion of
500,000 operating cycles.

Average values for a door with two TENSOR hinges

12

10

torque [Nm]
8

0
-90 -70 -50 -30 -10 10 30 50 70 90
opening angle [degree]

DORMA 3
Double-Action door hinge  TENSOR

4 DORMA
Double-Action door hinge  TENSOR

CONVINCING TECHNIQUE

..Hinge with spring-aided self-closing function, without damping Once correctly set, the door returns to “closed” quickly and reliably
..Max. torque 12 Nm (with 2 hinges) –­effective zero-point adjustment with TENSOR
..Applications: Interior doors (single or double-leaf) in private and
public environments 1. Pushing away from your body by hand, move the door panel
.. Not for sauna, baths or brine bath approx. 1 glass thickness from the desired zero position.
applications
.. Not suitable for single action door 2. Turn the bottom hinge adjustment screw clockwise until the door
applications panel begins to move.
..Versions for wall and frame fixing and also fixing to a glass side Then turn the adjustment screw in the top hinge clockwise until
panel the door panel has reached the zero position.
..Hold-open at 90° related to the zero position
..Fast and easy zero position adjustment - patent applied for 3. Pass through the door and return the panel to its zero position
..Max. door panel weight 65 kg by hand.
..Max. door panel width 1,000 mm
ideal ”0“ position

..Min. side panel width 700 mm (lower measures on request) 4. Tighten the adjustment screws in the top and bottom hinges
..Max. side panel width 1,500 mm by turning clockwise.
..For 8, 10 and 12 mm glass (TSG)
..TÜV-tested/third-party verification with respect to quality 5. Pass through the door again, and tighten the adjustment screws
and the production process; with confirmed completion of top and bottom from this side as well.
500,000 operating cycles
6. The door will always return to the adjusted position.
Finally, press the inlay caps into position.

1 2 3
ideale Nulllage
ideal "0" positionideal ”0“ position
approx. 1x
glass thickness

Principle of
adjustment

4 5 6
8.9 8.10

Die Stellschraube des oberen Türbandes im Uhrzeigersinn Durch die Tür gehen.
fest eindrehen (~5Nm / max. Handgelenkkraft) . Open and go through door.
Tighten setting screw of top hinge clockwise
(~5Nm / max. hand tight) .

8.11

DORMA 5
Double-Action door hinge  TENSOR

TENSOR SAMPLE

Installation onto wall or frame Dimensions of the desk sample:
with surface mounted mounting height 440 mm
plate width 430 mm
depth 250 mm
TENSOR double-action hinge
with reduced spring load for Art. No. 12.553
­demonstration purposes,
12 mm glass panel fixed to a Finish: Aluminium EV 1 Deco
timber construction mounted on
a support floor of black-dyed
MDF board

Installation glass to glass Dimensions of the desk sample:


height 520 mm
TENSOR double-action hinge width 500 mm
with reduced spring load for depth 250 mm
demonstration purposes,
12 mm glass panel, fixed to Art. No. 12.555
glass frame, inserted in support
floor of black-dyed MDF board Finish: Aluminium EV 1 Deco

6 DORMA
Double-Action door hinge  TENSOR

FOR WALL / FRAME FIXING


3
X+3

X+3

X
X
33 33 33 44

LH-10
1435*
LH-10
1435*

LH
LH
X+7

X+7

X
X

7
7

LB-6
LB-6 (LB-10)/2
(LB-10)/2
LB
LB LB
LB

TENSOR Double-action door fixed to wall/frame with surface TENSOR Double-action door fixed to wall/frame with surface
­ ounted mounting plate
m ­mounted mounting plate

Single leaf LH = clear height Double leaf LH = clear height


LB = clear width LB = clear width
Fittings for 8, 10 and Glass height = LH - 10 Fittings for 8, 10 and Glass height = LH - 10
12 mm glass Glass width = LB - 6 12 mm glass Glass width = (LB - 10) / 2
Door weight: max. 65 kg Door weight: max. 65 kg
Door width: max. 1,000 mm * for glass height 1,800 - 2,500 mm Door width: max. 1,000 mm * for glass height 1,800 - 2,500 mm

TENSOR Double-action hinges Glass preparation / Drilling scheme

100
70 86 24
3
50
16

2
Ø

R1
82
80
60

65

R1
6, 2
5
86
8/10 /12

127

4
36

70

Depending on wall plug

Pair of double-action hinges Finishes:


60

­incl. mounting plate, round; Alumin. EV 1 Deco (114)


for installation onto wall or Alumin. similar satin stainless
frame with surface mounted steel (113)
mounting plate Alumin. brass-coloured (105)
for 8, 10 and 12 mm glass
On request:
PLEASE NOTE: Condition is a suitable substructure!
Art. No. 12.520 Alumin. polished chromed (122)

Excessiv opening of the door must be prevented (max. 90°).


Please use a door stop – see page 10, Art. No. 29.950.

DORMA 7
Double-Action door hinge  TENSOR

FOR FRAME FIXING


3
3

3
3
X+3
X+3

X+3
X+3
X
X
3 3 1435* 3 3 3 3 4 4
1435*

1435*
1435*
LH-10
LH-10

LH-10
LH-10
LH
LH

LH
LH
X+7
X+7

X+7
X+7
7 X
X

7 X
X
7

7
LB-6
LB-6 (LB-10)/2
(LB-10)/2
LB LB LB LB

TENSOR Double-action door fixed to frame with embedded TENSOR Double-action door fixed to frame with embedded
mounting plate mounting plate

Single leaf LH = clear height Double leaf LH = clear height


LB = clear width LB = clear width
Fittings for 8, 10 and Glass height = LH - 10 Fittings for 8, 10 and Glass height = LH - 10
12 mm glass Glass width = LB - 6 12 mm glass Glass width = (LB - 10) / 2
Door weight: max. 65 kg Door weight: max. 65 kg
Door width: max. 1,000 mm * for glass height 1,800 - 2,500 mm Door width: max. 1,000 mm * for glass height 1,800 - 2,500 mm

TENSOR Double-action hinges Glass preparation / Drilling scheme

3
82 24
46 16

2
Ø

R1
82
65

65
82

R1
2

82
8/10/12

4 123
M8

36

R5
12
M8

Milled cutout
Pair of double-action hinges Finishes: 4 mm deep.

­incl. mounting plate; Alumin. EV 1 Deco (114)


65
82

for installation into frame with Alumin. similar satin stainless


embedded mounting plate steel (113)
for 8, 10 and 12 mm glass Alumin. brass-coloured (105)

Art. No. 12.522 On request: 38


Alumin. polished chromed (122)

PLEASE NOTE: Condition is a suitable substructure!


Excessiv opening of the door must be prevented (max. 90°).
Please use a door stop – see page 10, Art. No. 29.950.

8 DORMA
Double-Action door hinge  TENSOR

GLASS TO GLASS

3
3
3
3

X+3
X+3
X+3
X+3

X
X
X
X
3 3 3 3 3 3 4 4
1435*
1435*
LH-10
LH-10

LH-10
LH-10
1435*
1435*
LH
LH

LH
LH

X+7
X+7
X+7
X+7

7 X
X
7 X
X

7
7

LB-6
LB-6 (LB-10)/2
(LB-10)/2
LB LB LB LB

TENSOR Double-action door fixed to glass side panel TENSOR Double-action door fixed to glass side panel

Single leaf LH = clear height Double leaf LH = clear height


LB = clear width LB = clear width
Fittings for 8, 10 and Glass height = LH - 10 Fittings for 8, 10 and Glass height = LH - 10
12 mm glass Glass width = LB - 6 12 mm glass Glass width = (LB - 10) / 2
Door weight: max. 65 kg Door weight: max. 65 kg
Door width: max. 1,000 mm * for glass height 1,800 - 2,500 mm Door width: max. 1,000 mm * for glass height 1,800 - 2,500 mm

Side panel width: max. 1,500 mm Side panel width: max. 1,500 mm

TENSOR Double-action hinges Glass preparation 

3
46
24 38 82 24

R1
2 2
R1 16
16
82
82

65

R1
2
2
R1

38 82
8 /10/12
199 3
76 123
36

for Art. No. 12.523

Pair of double-action hinges for 21


8
installation glass to glasse Ø1

for 8, 10 and 12 mm glass


50 *

Tension cut
Art. No. 12.523
21 *Recommendation

Finishes:
Alumin. EV 1 Deco (114) 3
Alumin. similar satin stainless
Overpanel-sidelight connector
steel (113) Sidelight Overpanel
Art. No. 12.536
Alumin. brass-coloured (105)
Weight in kg:
On request:
aluminium 0.146
Alumin. polished chromed (122)

Excessiv opening of the door must be prevented (max. 90°). for Art. No. 12.536
Please use a door stop – see page 10, Art. No. 29.950.

DORMA 9
Double-Action door hinge  TENSOR

ACCESSORIES

Ordering information

Wall Stop for pivoting door


Glass floor mounting
Art. No. 29.950

24,5
40

Floor

10 DORMA
Double-Action door hinge  TENSOR

SAFETY-RELATED INFORMATION

Important safety-related infor- Mounting Maintenance
mation for the mounting and 1. Only properly qualified and Check fittings at regular inter-
use of DORMA glass fittings. specially trained staff is vals for proper positioning and
(Follow these instructions in ­authorised to mount DORMA smooth running and door for
­addition to the mounting and glass fittings. correct adjustment. Especially
operating instructions in order 2. Never use glass with conchoi- highly-frequented door systems
to avoid damage of product and dal fractures and/or damaged require inspection by properly
damage to person or property.) edges. qualified staff (specialised com-
Important: All users have to be 3. Due to crushing hazards – panies or installation firms).
informed about relevant points among others in the area of ­Immediately replace damaged
mentioned in these safety- the secondary closing edge – class elements (no glass flaking
related information and the and possible injury caused by and/or conchoidal fractures)!
mounting and operating instruc- breakage of glass during
tions! mounting, corresponding pro-
tective clothing (especially
General information gloves and protective gog-
1. DORMA recommends using gles) is required.
TSG-H (heat soaked tough- 4. Clean clamping area with fat
ened safety glass) to DIN EN solvent (standard commercial
12150-1. cleaning agent) before
2. DORMA glass fittings are not mounting the glass fitting.
suitable for application in 5. Never use clamping shoes on
rooms where chemicals (e. g. structured glass surfaces
chlorine) are used such as ­(except on satined glass) or
indoor swimming pools, sau- glass of heavily varying thick-
nas or salt-water pools. ness unless with a corre-
3. Never move sliding panels sponding levelling layer.
faster than walking speed and 6. Never use clamping shoes on
always stop the door manually self-cleaning coatings.
before it reaches end position. 7. When adjusting glass ele-
4. Do not shut swing doors with ments, always stick to the
excessive force. Install door ­required clearance for the
stop to prevent door from ­respective fitting. Adjust
opening too far. clearance so that the glass
does not touch hart compo-
nents such as glass, metal or
concrete.
8. Make sure not to use exces-
sive force when installing the
glass (avoid local stress
resulting from very tight
screws).

DORMA 11
WN 05415751532 · 09/12 · GB · 3 · JP · 10/12

DORMA GmbH + Co. KG DORMA-Glas GmbH


DORMA Platz 1 Max-Planck-straße 33–45
58256 EnnEPEtAl 32107 BAD sAlzuFlEn
GERMAny GERMAny
Phone +49 2333 793-0 Phone +49 5222 924-100
Fax +49 2333 793-4950 Fax +49 5222 924-3100
www.dorma.com www.dorma.com

S-ar putea să vă placă și