Documente Academic
Documente Profesional
Documente Cultură
as of 12/1/2011
ALL DIMENSIONS ARE INCHES UNLESS PROPRIETARY MATERIAL
OTHERWISE SPECIFIED REMOVE ALL THE INFORMATION CONTAINED WITHIN IS THE PROPERTY
BURRS & SHARP EDGES, R.02 MAX. OF SERVAGROUP AND SHALL NOT BE REPRODUCED,
DISTRIBUTED OR DISCLOSED TO OTHERS EXCEPT
WHEN SPECIFICALLY AUTHORIZED IN WRITING.
THIRD ANGLE
as of 12/1/2011
air dryers
AD-9™ AIR DRYER AHEAD OF THE CURVE™
Proven Design
Bendix air dryers have been proving themselves for nearly 30
years. In fact, the AD-9™ model is the industry-standard air
dryer because of its proven performance and reliability. No
other air dryer has logged as many miles as the AD-9. It is built
to endure. The AD-9™ dryer is also a completely self-contained
unit and doesn’t require an extra purge tank or additional
valves. And unlike some air dryers, the AD-9™ dryer doesn’t
steal air from the air brake system to complete a system purge.
Simple Service
Ease of service is another reason the Bendix AD-9™ unit is such
a popular air dryer. If service of the check valve, turbo cut-off
valve, heater or purge valve is ever required, it can be done
without disassembling the air dryer. That’s because most
components of the AD-9™ dryer are externally serviceable. Our
exceptional design, extensive testing, long-lasting perform-
ance and ease of service give you an air dryer with superior
technology, low maintenance and low cost of ownership.
Premium Desiccant
Our premium, high-crush-strength desiccant is produced with
a composition that is more efficient and longer lasting than
other desiccants. It also provides outstanding protection
against contamination and desiccant breakdown.
Excellent Warranty
We’re so confident that the Bendix® AD-9™ air dryer will
®
properly protect your air brake system that we warrant
it for three years or 350,000 miles. And if it’s installed as
original equipment on the vehicle, you’re eligible for our
T.A.G.™ (Total Air Guarantee) program. The T.A.G.™ program
air dryers
AD-9™ AIR DRYER AHEAD OF THE CURVE™
extends the warranty of other Bendix air and antilock brake Applications
system components also installed as original equipment to School Bus: 2-3 braked axles
three years or 350,000 miles. For T.A.G. warranty details, see
Highway
Bendix® publication BW1716. Travel Coach: 2-3 braked axles
Pick-up and
Recyclable Cartridge Delivery: 2-7 braked axles
The desiccant cartridge in the Bendix AD-9™ air dryer can be Line Haul: 2-8 braked axles
completely removed and recycled. When you buy a replace-
Rural or
ment Bendix air dryer replacement cartridge, simply return Commercial Refuse: 2-4 braked axles
your used one to us. We’ll recycle parts of the used cartridge Residential Refuse
and properly dispose of the rest. You never come in contact with Work Brake: 2-4 braked axles
with the used desiccant, you don’t have to pay any disposal Dump Truck: 2-3 braked axles
costs, and you can feel good knowing you’re doing your part
Off-Highway/
to protect the environment. Construction: 2-6 braked axles
Heater: 12 or 24 volts/
Protect Your Investment thermostatically 75 watts
There's no substitute for Genuine Bendix parts. Take a good controlled
look at the remanufactured Bendix® AD-9TM air dryer and Type of Mounting: Vertical
(can be rotated in
cartridge before you buy. Be sure to look for our distinctive 45-degree increments
for seven port positions)
"Genuine Bendix" inscription on the cartridge keeper ring to
Inlet/Outlet Ports: 1/2 inch
ensure that you are buying a Genuine Bendix cartridge. If it's
not there, it's not a Genuine Bendix. Only Bendix Commercial Governor Port: 1/4 inch
Vehicle Systems produces legitimate Bendix® AD-9TM air dryer Warranty: 3 years / 350,000 miles
(for complete details refer to AD-9™ air dryer warranty,
remanufactured cartridges that have been designed, BW1715) Service Kits: Refer to catalog pages 08-A-9
through 08-A-13 for current service kit numbers
developed, and tested for your Bendix® AD-9TM air dryer.
Clean Dry Air Where It Counts With The Bendix® AD-9™ Air Dryer
Integrated design, improved performance and reduced maintenance time. Discover how the Bendix® AD-9™ air dryer can
enhance your commercial vehicle. Talk to your Bendix Account Manager, call 1-800-AIR-BRAKE, or visit www.bendix.com today.
Bendix Commercial Vehicle Systems LLC • 901 Cleveland Street • Elyria, Ohio 44035 • 1-800-AIR-BRAKE (1-800-247-2725) • www.bendix.com
BW2088 • ©2004 Bendix Commercial Vehicle Systems LLC, a member of the Knorr-Bremse Group • 03/04 • All Rights Reserved • Printed in U.S.A.
Cv = .52 - .73
TECHNICAL SPECIFICATIONS
PNEUMATIC DATA
Operating pressure 0 - 10 bar, (0 - 145 psi) (down to -.9 bar vacuum; 28" Hg with series 3)
Nominal pressure 6 bar, (87 psi)
Nominal flow *Qn Series 3: 1/8” = 700 NL/min. (24.7 SCFM)
Series 1: 1/8” = 500 NL/min. (17.65 SCFM)
Nominal diameter 1/8” = 5 mm
Cv Rating Series 3: 1/8” = 0.73
Series 1: 1/8” = 0.52
*Qn flowrate (SCFM) determined with a supply pressure of 6 bar (87 psi), and with a pressure drop of 1 bar (14.5 psi).
** Soft-seal repair kits are available on request.
***Dimensions are in millimeters
The company reserves the right to vary models and dimensions without notice.
12 These products are designed for industrial applications and are not suitable for sale to the general public.
Cv = .52 - .73
CODING OF MINIVALVES
1
manual valves
158 -900TF
Series PORTS
1- Poppet Type TF = NPTF
3 - Spool Type
Mod. 138-935TF Mod. 138-900TF Mod. 158-900TF Mod. 338-990TF Mod. 358-990TF Mod. 338-895TF Mod. 358-895TF
Mod. 338-896TF Mod. 358-896TF
Mod. 338-897TF Mod. 358-897TF
Mod. 338-975TF Mod. 358-975TF Mod. 338-910TF Mod. 358-910 TF Mod. 338-900TF Mod. 358-900TF Mod. 368-900TF Mod. 378-900TF
Mod. 338-976TF Mod. 358-976TF Mod. 338-915TF Mod. 358-915 TF Mod. 338-905TF Mod. 358-905TF Mod. 368-905TF Mod. 378-905TF
Mod. 338-977TF Mod. 358-977TF
The company reserves the right to vary models and dimensions without notice.
These products are designed for industrial applications and are not suitable for sale to the general public. 13
Cv = .73
Actuation Force at 87 psi = 4.04 lbf Actuation Force at 87 psi = 4.04 lbf
1/8 NPTF
1/8 NPTF
Actuation Force at 87 psi = 7.9 lbf Actuation Force at 87 psi = 7.9 lbf
NPTF
NPTF
The company reserves the right to vary models and dimensions without notice.
14 These products are designed for industrial applications and are not suitable for sale to the general public.
Cv = .73
manual valves
NPTF
NPTF
Valves Mod. 338-910TF and Mod. 338-915TF Cv = .73 Valves Mod. 358-910TF and Mod. 358-915TF Cv = .73
338-910TF Actuation Force at 87 psi = 1.35 lbf 358-910TF Actuation Force at 87 psi = 1.35 lbf
338-915TF Actuation Force at 87 psi = 7.9 lbf 358-915TF Actuation Force at 87 psi = 7.9 lbf
NPTF
NPTF
Mod. Mod.
338-910TF 358-910TF
Mod. Mod.
338-915TF 358-915TF
The company reserves the right to vary models and dimensions without notice.
These products are designed for industrial applications and are not suitable for sale to the general public. 15
Cv = .73
1 Valves Mod. 338-900TF and Mod. 338-905TF Cv = .73 Valves Mod. 358-900TF and Mod. 358-905TF Cv = .73
manual valves
338-900TF Actuation Force at 87 psi = 1.35 lbf 358-900TF Actuation Force at 87 psi = 1.35 lbf
338-905TF Actuation Force at 87 psi = 7.9 lbf 358-905TF Actuation Force at 87 psi = 7.9 lbf
*Detent force can be adjusted by means of 5 spring- *Detent force can be adjusted by means of 5 spring-loaded screws on
loaded screws on the side of handle interface the side of handle interface
NPTF
NPTF
Mod. Mod.
338-900TF 358-900TF
Mod. Mod.
338-905TF 358-905TF
Actuation Force at 87 psi = 1.35 lbf Actuation Force at 87 psi = 4.5 lbf
*Detent force can be adjusted by means of 5 spring-loaded screws on *Detent force can be adjusted by means of 5 spring-loaded screws on
the side of handle interface the side of handle interface
NPTF
NPTF
Mod. Mod.
368-900TF 368-905TF
The company reserves the right to vary models and dimensions without notice.
16 These products are designed for industrial applications and are not suitable for sale to the general public.
Cv = .73
manual valves
*Detent force can be adjusted by means of 5 spring-loaded screws on
the side of handle interface
NPTF
NPTF
Mod.
Mod.
378-900TF
378-905TF
The company reserves the right to vary models and dimensions without notice.
These products are designed for industrial applications and are not suitable for sale to the general public. 17
Cv = .52
1/8"
NPTF
Mod.
138-935TF
1/8"
Mod. NPTF
138-900TF
1/8"
NPTF
Mod.
158-900TF
The company reserves the right to vary models and dimensions without notice.
18 These products are designed for industrial applications and are not suitable for sale to the general public.
Page 1 of 1
Specifications:
DQ60200 Isolator Pad Kit
Notes:
1) All tanks have 1/4" drain port in bottom.
2) All tanks have (2) 3/8" charging ports, one on each end.
3) Valve ports on same side - 19842 only.
19840 Shown
Material Specification.................................................................................................................... 6
Flow Characteristics...................................................................................................................... 8
Manifold Dimensions..................................................................................................................... 27 - 32
Important ! NB !
Before carrying out any service work, ensure that
All technical data in this catalogue is typical only.
the valve and manifold have been vented.
Remove the primary supply air hose to ensure The air quality is decisive for the valve life:
total disconnection of the air supply before see ISO 8573.
dismantling valves or blank connection blocks.
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical ex-
pertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and
applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change
by Parker Hannifin Corporation and its subsidiaries at any time without notice.
SALE CONDITIONS
The items described in this document are available for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. Any sale contract entered into by Parker will be governed by
the provisions stated in Parker’s standard terms and conditions of sale (copy available upon request).
Extreme
Environments
Demand The Viking Xtreme
The Viking Xtreme valve range is robust, versatile and
combines high performance with compact installation
dimensions. Large flow capacity, short change-over
times and low change-over pressure are important
characteristics of this valve range.
New manually
The 1/8 & 1/4 sizes are designed to operate with operated valves
pressures up to 16 bar and the 3/8 & 1/2 sizes up to The range now includes lever
12 bar, in ambient temperatures -40OC to + 60OC when operated versions. They feature
fitted with suitable solenoid operators. a rugged hand lever specifically
designed for gloved hands and are
Viking Xtreme range available in 5/2 and 53 functions
In the chart below you can find the suitable valves, tubes etc. for each
cylinder size. If you have a tube length over 2 m, choose one tube size
larger than in the chart.
Cylinder port M5 G1/8 G1/4 G3/8 G3/8 G1/2 G1/2 G3/4 G3/4
4/2.7 6/4 8/6 10/8 10/8 12/9 14/11 18/15 20/18
Tubing Ext/Int
6/4 8/6 12/9 14/11
P2LAX G1/8 G1/8 G1/8 G1/8 G1/8
P2LBX G1/4 G1/4 G1/4 G1/4 G1/4 G1/4
P2LCX G3/8 G3/8 G3/8 G3/8 G3/8
P2LDX G1/2 G1/2 G1/2 G1/2 G1/2 G1/2
Material specification
P2LAX P2LBX
Valve Valve
Valve body Anodised aluminium Valve body Anodised aluminium
End covers Anodised aluminium End covers Anodised aluminium
Lever housing Acetal plastic Lever housing Anodised aluminium
Spool Aluminium + nitrile rubber Spool Aluminium + nitrile rubber
Piston Acetal plastic/ Anodised aluminium Piston Acetal plastic/ Anodised aluminium
End cover sealings Nitrile rubber End cover sealings Nitrile rubber
End cover screws Stainless steel End cover screws Stainless steel
Springs Dacromet® - processed steel, Springs Dacromet® - processed steel,
Stainless steel Stainless steel
Lever Reinforced polyamid plastic Mounting screws for solenoid Stainless steel
Panel mounting nut Polycarbonate plastic
Gaiter Chloroprene rubber
Mounting screws for solenoid Stainless steel
Accessories Accessories
Manifold bar Anodised aluminium Manifold bar Anodised aluminium
Pressure bar Anodised aluminium Pressure bar Anodised aluminium
Multiple manifolds Anodised aluminium
End and intermediate blocks Anodised aluminium
P2LCX P2LDX
Valve Valve
Valve body Anodised aluminium Valve body Anodised aluminium
End covers Anodised aluminium End covers Anodised aluminium
Spool Aluminium + nitrile rubber Spool Aluminium + nitrile rubber
Piston Acetal plastic/ Anodised aluminium Piston Acetal plastic/ Anodised aluminium
End cover sealings Nitrile rubber End cover sealings Nitrile rubber
End cover screws Stainless steel End cover screws Stainless steel
Springs Dacromet® - processed steel, Springs Dacromet® - processed steel,
Stainless steel Stainless steel
Mounting screws for solenoid Stainless steel Mounting screws for solenoid Stainless steel
Flow characteristics
Flow capacities in accordance with ISO6358
All pressures = effective pressure
The curves in the diagram below are typical only
Order chart - Viking Xtreme air pilot & lever valves - Xtreme operating pressure / temperature
P 2 L A X 5 1 1 P S
Version
X Xtreme duty spool
Symbol Size Actuation Return Min Operating Changeover Weight Order code
Pressure (bar) time (ms) Kg
at 6 bar @20OC
actua./return
14 513 12
G3/8 position centring 3,5 15/35 0,50 P2LCX813PP
G1/2 3,5 15/35 0,50 P2LDX814PP
4 2
G1/8 Air signal Air signal 3,5 10/20 0,15 P2LAX711PP
14 513 12
G1/4 Pressurised Self 3,5 12/22 0,33 P2LBX712PP
G3/8 centre centring 3,5 15/35 0,50 P2LCX713PP
G1/2 position 3,5 15/35 0,50 P2LDX714PP
Symbol Size Actuation Return Changeover Type Weight Order code
angle Kg
4 2 G1/4
Pressure applied centre ±12O Std. 0,33 P2LBX71222
513 position held in three
G3/8 ±16O Std. 0,71 P2LCX71322
positions
G1/2 ±16O Std. 0,73 P2LDX71422
P 2 L A X 5 1 1 E S N D D B 4 9
7 E * Extended - locking 45 12
5/3 valve pressurised centre
X Less 15mm solenoid 47* 12
8 5/3 valve vented centre
* Only available with enclosure 5 48* 24
Solenoid operated with external pilot supply to solenoids 1 22mm solenoid option 49 24
through ports #12 & #14
53 120 110
N 5/2 valve 57 240 230
P 5/3 valve closed centre position valve less
XX
solenoid/coil
Q 5/3 valve pressurised centre
* If 22mm solenoid required on
mobile applications use
R 5/3 valve vented centre model code no page 16.
Alternatively check operating
temperature and pressures
with our technical department.
2
Shaded part numbers are available from stock
Pilot main actuator / Return Unshaded part numbers are available on request but will be
subject to minimum order quantities
E Solenoid operated valve Otherwise order coil/solenoid and valve separately.
Shaded part numbers are standard N 22mm solenoid pilot less coil
X Valve less 15mm solenoid
L** Low power 22mm solenoid
(only available with 24V DC)
Solenoid operated directional control valves fitted with 15mm solenoid(s) 24V DC
Solenoid plug/connector to ordered separately. See page 39
Internal supply to solenoid valve(s) via port 1. Max operating pressure 10 bar, temp range -10OC to +50OC
Symbol Size Actuation Return Min Operating Changeover Weight Order code
Pressure (bar) time (ms) Kg
at 6 bar @20OC
actua./return
14 513
G1/4 12
Closed centre Self 3,5 22/55 0,44 P2LBX612EENXB549
G3/8 position centring 3,5 30/90 0,55 P2LCX613EENXB549
G1/2 3,5 30/95 0,55 P2LDX614EENXB549
4 2
G1/8 Electric signal Electric signal 3,5 18/40 0,28 P2LAX811EENXB549
14 513 12 G1/4 Vented centre Self 3,5 22/55 0,44 P2LBX812EENXB549
G3/8 position centring 3,5 30/90 0,55 P2LCX813EENXB549
G1/2 3,5 30/95 0,55 P2LDX814EENXB549
4 2
G1/8 Electric signal Electric signal 3,5 18/40 0,28 P2LAX711EENXB549
14 513 12 G1/4 Pressurised Self 3,5 22/55 0,44 P2LBX712EENXB549
G3/8 centre centring 3,5 30/90 0,55 P2LCX713EENXB549
G1/2 position 3,5 30/95 0,55 P2LDX714EENXB549
Solenoid operated directional control valves fitted with adapter to accept 15mm solenoid(s)
Solenoid operator(s) and connector/plug(s) should be ordered separately. See page 35 & 39
Internal supply to solenoid valve(s) via port 1. Max operating pressure 10 bar, temp range -10OC to +50OC
Symbol Size Actuation Return Min Operating Changeover Weight Order code
Pressure (bar) time (ms) Kg
at 6 bar @20OC
actua./return
Solenoid operated directional control valves fitted with adapter to accept 15mm solenoid(s)
Solenoid operator(s) and connector/plug(s) should be ordered separately. See page 35 & 39
External supply to solenoid valve(s) via ports 12 & 14. Max operating pressure 10 bar, temp range -10OC to +50OC
Symbol Size Actuation Return Min Operating Changeover Weight Order code
Pressure (bar) time (ms) Kg
at 6 bar @20OC
actua./return
Solenoid operated directional control valves fitted with 22mm solenoid(s) 24V DC
Solenoid plug/connector to be ordered separately. See page 39
Internal supply to solenoid valve(s) via port 1. Max operating pressure 10 bar, Temperature range -10OC to +50OC
Symbol Size Actuation Return Min Operating Changeover Weight Order code
Pressure (bar) time (ms) Kg
at 6 bar @20OC
actua./return
14 513 12
G3/8 centre centring 3,5 30/90 1,11 P2LCX713EENDDB49
G1/2 position 3,5 30/90 1,11 P2LDX714EENDDB49
Symbol Size Actuation Return Min Operating Changeover Weight Order code
Pressure (bar) time (ms) Kg
at 6 bar @20OC
actua./return
14 1 3 12
5 G3/8 3,5 16/60 0,40 P2LCX513ESNDDN
G1/2 3,5 16/60 0,40 P2LDX514ESNDDN
G1/8 Electric signal Air signal 1,5 9/9 0,16 P2LAX511EPNDDN
4 2 G1/4 1,5 10/10 0,31 P2LBX512EPNDDN
14 5 1 3 12 G3/8 1,5 13/13 0,40 P2LCX513EPNDDN
G1/2 1,5 13/13 0,40 P2LDX514EPNDDN
14 513 12
G3/8 position centring 3,5 20/65 1,00 P2LCX813EENDDN
G1/2 3,5 20/70 1,00 P2LDX814EENDDN
4 2
G1/8 Electric signal Electric signal 3,5 15/40 0,17 P2LAX711EENDDN
G1/4 Pressurised Self 3,5 18/50 0,33 P2LBX712EENDDN
G3/8 centre centring 3,5 20/65 1,00 P2LCX713EENDDN
14 513 12
Solenoid operated directional control valves (supplied with 22mm solenoid less coil)
See page 35 & 39 for coil and connector part numbers
External supply to solenoid valve(s) via ports 12 and 14. Standard temp. range -10OC to +50OC. Max operating pressure 10 bar
Symbol Size Actuation Return Min Operating Changeover Weight Order code
Pressure (bar) time (ms) Kg
at 6 bar @20OC
actua./return
14 513 12
G3/8 1,5 13/13 0,70 P2LCXN13EENDDN
G1/2 1,5 13/13 0,70 P2LDXN14EENDDN
G1/8 Electric signal Spring 3,2 12/38 0,16 P2LAXN11ESNDDN
4 2
G1/4 3,5 14/42 0,30 P2LBXN12ESNDDN
G3/8 3,5 16/60 0,70 P2LCXN13ESNDDN
14 5 1 3 12
P 2 L A X 5 1 1 E S H D D B 4 9
Version
X Xtreme duty spool
5 D Extended non-locking AC DC
5/2 valve
60Hz 50Hz
6 5/3 valve closed centre position
40 12
7 5/3 valve pressurised centre 42 24 22
8 5/3 valve vented centre 45 12
47* 12
Solenoid operated with external pilot supply to solenoids
through ports #12 & #14 48* 24
N 49 24
5/2 valve
53 120 110
P 5/3 valve closed centre position
57 240 230
Q 5/3 valve pressurised centre valve less
XX
solenoid/coil
R 5/3 valve vented centre
* Mobile voltage see page 32
operating parameters
3
Shaded part numbers are available from stock
Unshaded part numbers are available on request but will be
subject to minimum order quantities
Pilot main actuator / Return Otherwise order coil and valve separately.
P Press (return only) A 22mm Solenoid pilot & 30mm coil Form A
B 22mm Solenoid pilot & 22mm coil Industrial Form B
Shaded part numbers are standard N 22mm Solenoid pilot less coil
Symbol Size Actuation Return Min Operating Changeover Weight Order code
Pressure (bar) time (ms) Kg
at 6 bar @20OC
actua./return
Symbol Size Actuation Return Min Operating Changeover Weight Order code
Pressure (bar) time (ms) Kg
at 6 bar @20OC
actua./return
Dimensions
P2LAX... all
5/2 and 5/3 valves
Solenoid valves
Solenoid valves and cable plugs must be ordered separately.
One pilot valve is required for each E in the valve order code.
Dimensions
P2LAX - Lever operated directional control valves
48 40
3,5
Ø4,1 (x5)
30
33
8 8
Ø22,5
5
22
1 3
28
16
3
40 102
Dimensions
P2LBX - 5/2 Lever operated directional control valves
20o
Ø28
131.75
Ø3.1 (x2)
22.2
5 5 16.5
2.85 40
49
46
Ø4.3 (x4)
32
20
4
118.5
Ø3.1 (x2)
22.2
16.5
5 5 40
2.85
59.75
46
Ø4.3 (x4)
32
20
4
140
Dimensions
P2LCX - 5/2 Lever operated directional control valves
133 32o Ø28
Ø4.4 (x2)
35.5 35.5
23
30
3.5
70 48
53 Ø6.9 (x2)
11
157.5
16o Ø28
16o
136.25
35.5 35.5
Ø4.4 (x2)
26.5
30
81 48
3.5
53
Ø6.9 (x2)
11
179.5
Dimensions
P2LDX - 5/2 Lever operated directional control valves
32o
Ø28
133
42 42
Ø4.4 (x2)
30
23
70 48
3.5
7.5
34 Ø6.6 (x2)
157.5
16o Ø28
16o
136.25
Ø4.4 (x2)
42 42
30
23
3.5
81 48
7.5
34
Ø6.9 (x2)
179.5
Dimensions
P2LBX... all
5/2 and 5/3 valves
14
5/3 valve = 119,5
5
5/2 valve = 98
4
1
2
3
12
*
*
*
*
*
Solenoid valves
* Note: 5/3 valves - add 21.5mm Solenoid valves and cable plugs must be ordered separately.
One pilot valve is required for each E in the valve order code.
Dimensions
P2LCX... all
5/2 and 5/3 valves
14
5
4
1
2
12
3
*
*
*
*
Solenoid valves
* Note: 5/3 valves - add 22.0mm Solenoid valves and cable plugs must be ordered separately.
One pilot valve is required for each E in the valve order code.
Dimensions
P2LDX... all
5/2 and 5/3 valves
14
5
4
1
2
12
3
*
*
Manifold:
with common channels
for ports 1, 3 and 5.
Intermediate block L:
enables the block to be
divided for different
supply pressure. Top
or bottom ported.
Intermediate block T:
permits the connection
Connection block S: Blanking plate: of air between two
straight connection block To incorporate spare manifolds. Top or
with a side ports for positions. bottom ports.
common air supply and
exhaust.
Various mounting options
Connection block L:
angled connection block 2. With M5 screws from
for top or bottom ported. the top in any manifold
1. With M6 screws for
installation from the
connection blocks.
End cover
5 1 3
Mounting screws in stainless steel for valve and blanking plate, see page 31
Dimensions
6 12
30 24
Dimensions
19
4
12
49 Ø7(4x)
G3/8
No. of L
27
valves mm
4 126
6 174 Blanking plate for
(70)
10 270
19
4
12
12 318 49 Ø7(4x) 2 94 56
G3/8
L
27
Dimensions
Ø5.5 (x4)
Ø8
13.25
20
5
20
13.25
valves mm
2 92
30.5
4 140
4.5
6 188
G3/8 (x6)
8 236
No. of L Blanking plate 10 284
valves mm for manifold bar,
P2LB
2 74
4 122
6 170
8 218
10 266
Corrosion-resistant
materials.
P2E - Q V 3 2 C 3
Technical data
NC, Standard NC, Food1) NC, Mobile2)
Working pressure 0 to10 bar 0 to 10 bar 0 to 10 bar
Working temperature -15 °C to +60 °C -15 °C to +60 °C -40 °C to +70 °C
Orifice 1,0 mm 1,0 mm 1,0 mm
Flow Qmax 33 Nl/min 33 Nl/min 22 Nl/min
Power, hold DC 1,2 W / AC 1,6 VA DC 1,2 W / AC 1,6 VA DC 1 W
Power, surge DC 1,2 W / AC 3,5 VA DC 1,2 W / AC 3,5 VA DC 1 W
Connection time 100% 100% 100%
Voltage tolerance +10%/–15% +10%/–15% +25%/–30%
Electric connection: Form C/ISO15217
Port pattern: To future CNOMO standard
Protection: IP 65
Approval: Some valves are UL 429 recognised and marked with the following symbol
Working media: All neutral media, such as compressed air, water, hydraulic oil and many gases.
1) Design: Completely smooth exterior, suitable for food industry.
2) Mobile standard According to European standard EN 50 155.
Transients Materials
Interrupting the current through the solenoid coil produces momentary Operator
voltage peaks which, under unfavourable conditions, can amount to
several hundred times the rated operating voltage. Normally, these Body, coil casing Thermoplastic
transients do not cause problems, but to achieve the maximum life of Internal metal parts Steel
relays in the circuit (and particularly of transistors, thyristors and Screws Stainless steel
integrated circuits) it is desirable to provide protection by means of Bottom plug Thermoplastic
voltage-dependent resistors (varistors). All cable plugs with a yellow Sealing materials FPM (Viton™) and nitrile rubber
LED also incorporate such protection.
Cable head
Solenoid assembly
(pins up shown)
Seal
Solenoids 15 mm NC, food industry version (Note! Mounting screws included in basic valve)
Voltage Weight Order code Weight Order code Weight Order code
Kg Without manual Kg Override, blue, Kg Override, yellow,
override non locking flush locking flush
24 VDC 0,038 P2E-QV32C0 0,038 P2E-QV32C1 0,038 P2E-QV32C2
48 VDC 0,038 P2E-QV32D0 0,038 P2E-QV32D1 0,038 P2E-QV32D2
24 VAC 50Hz 0,038 P2E-QV31C0 0,038 P2E-QV31C1 0,038 P2E-QV31C2
48 VAC 50/60Hz 0,038 P2E-QV34D0 0,038 P2E-QV34D1 0,038 P2E-QV34D2
115 V 50Hz/ 0,038 P2E-QV31F0 0,038 P2E-QV31F1 0,038 P2E-QV31F2
120 V 60Hz
230 VAC 50Hz/ 0,038 P2E-QV31J0 0,038 P2E-QV31J1 0,038 P2E-QV31J2
240 VAC 60Hz
In accordance with the EU Machine Directive, EN 983, solenoid valves with manual override should have spring-return operating arms for safety.
The pilot operator body is manufactured in thermoplastic Viking Xtreme valves are tested to +5g shock and vibration.
PA 6 material and the core tube brass/stainless steel. The Solenoid operated valves are designed to operate with wide
plunger/core is made from stainless steel and the valve voltage tolerance bands within the ambient temperature
seats from FKM. ranges stated in the technical section.
These operators all exhaust out of the top of the core tube The pilot operators can be supplied with or without manual
which is tapped M5. The standard solenoid nut fitted to override. The standard manual override is the monostable
the core tube is the Diffuser nut which allows the exhaust (spring return) extended brass override. Alternatively the
to escape to atmosphere. This nut also minimises ingress bistable (locking) override can be specified as an
of dirt into the valve through this port. The alternative alternative for the Normal duty 10bar option.
plastic knurled nut can be specified (refer to part number
system) if the exhaust air needs to be captured and piped
away using the M5 tapped port.
Spares
Coils
Solenoid operators are available as spares complete with
Coils are wound with enameled copper wire, having mounting screws and seals. Coils and connectors should
temperature index 1800C with class F insulation (1550C) be ordered separately.
and are encapsulated in Thermoplastic resin. When
fitted with suitable connector and correct gasket they give
protection to IP65.
P2F P 1 3 N 4 C
Technical data
NC Normal NC Xtreme NC 22mm Xtreme NC 30mm Xtreme
(Mobile) (Mobile)
Transients Coil
Voltage Order code Form A Weight (Kg) Order code Form B Weight (Kg)
Note: Mobile solenoids are only suitable for Viking Xtreme valves with 'H' specification having 0,8/1,0 operator type P2FP13H4D
Spare Solenoid Nuts
Valves requiring captured exhaust should Valves with vented exhaust are fitted
be fitted with plastic knurled nut with diffuser plastic nut
@ P2FNP @ P2FND
Solenoid pilot operator 22mm NC, Normal duty Low power pilot operator NC, Normal duty
(Max Operating pressure 10bar, Temp –100C to +500C) (Max Operating pressure 10bar, Temp –100C to +500C)
Order code weight Order code weight Order code weight Order code weight
(with locking Kg (with Non-locking Kg (with locking Kg (with Non-locking Kg
bi-stable m/o) monostable m/o) bi-stable m/o) monostable m/o)
P2FP13H4D 0.05kg
Note.
Solenoid pilot operators are fitted to the Viking valve range. Order
the above part numbers for spares. The operators are supplied
with mounting screws and interface ‘O’ rings.
Coils and connectors must be ordered separately.
With standard screw Standard IP65 P8C-D 3EV10V10 3EV290V10
without flying lead
With LED and protection P8C-D26C 3EV10V20-24 3EV290V20-24
24V AC/DC
With LED and protection P8C-D21E 3EV10V20-110
110V AC
With LED and protection 3EV10V20-230
230V AC
With cable Standard with 2m cable IP65 P8L-C2
Standard with 5m cable IP65 P8L-C5
24V AC/DC, 2m cable P8L-C226C
LED and protection IP65
24V AC/DC, 5m cable P8L-C526C 3EV10V20-24L5 3EV290V20-24L5
LED and protection IP65
24V AC/DC, 10m cable P8L-CA26C
LED and protection IP65
110V AC/DC, 2m cable P8L-C221E
LED and protection IP65
110V AC/DC, 5m cable P8L-C521E 3EV10V20-110L5
LED and protection IP65
230V AC, 5m cable 3EV10V20-230L5
LED and protection IP65
35
P8C-C21E
0,3
P8C-D 15,5
P8C-D26C
8,1
P8C-D21E
40
3,8
3,2
2
Cable plugs
8,2
3
P8L-C2
3,8
22,2 2
9,7 P8LC5
1
P8L-C226C
P8L-C526C
18
P8L-CA26C
P8L-C221E
22
Ø 5,5
P8L-C521E
17
40,5
28,5
26
30 20,8
22
31
46
3EV10V10
40
54
5,5
30
32
30 31
5
M3
35,5
3EV290V10
28,5
26
31
22
47,5
42
17
47
54
Accessories
Sintered bronze series Male straight connectors - Parallel thread
Port Order code Pack Qty Tube Thread Order code Box Qty
Ø1 B
M5 9721900005 1 4 1/8 F4PMB4-1/8 20
G1/8 9090050700 1 6 1/8 F4PMB6-1/8 30
G1/4 P6M-BAA2 1 6 1/4 F4PMB6-1/4 30
G3/8 9090050900 1 8 1/8 F4PB8-1/8 40
8 1/4 F4PB8-1/4 30
G1/2 9090051000 1
8 3/8 F4PB8-3/8 20
10 1/4 F4PB10-1/4 20
10 3/8 F4PB10-3/8 20
10 1/2 F4PB10-1/2 10
12 1/4 F4PB12-1/4 10
12 3/8 F4PB12-3/8 10
12 1/2 F4PB12-1/2 10
14 3/8 F4PB14-3/8 10
14 1/2 F4PB14-1/2 10
© 2010 Parker Hannifin Corporation. All rights reserved. Catalogue PDE2569TCUK. February 2010