9900V

MICROCODE VERSION 21-14-28-00/00


RELEASED 08/23/06
Newly supported features and functions for Version 21-14-28-00/00
NONE

The change of contents for Version 21-14-28-00/00


(1) Subsystem cannot be started after power failure
Item Description
Contents When starting a subsystem after a power failure, either of the following phenomena may occur.
<Phenomenon 1> Not started due to WCHK1 in all MPs
<Phenomenon 2> MP in Fibre Channel CHA is blocked.
When starting subsystem, if the version of micro-program stored in SM and that stored in FM
are different, the micro-program stored in SM downloads. When downloading it, the micro-
program stored in the FM downloaded due to a micro-program failure. Since the version of the
running micro-program was different from that stored in the SM, the MP was blocked. As a
result, when all CHA MPs are blocked, <Phenomenon 1> will occur, and when some of CHA
MPs are blocked, <Phenomenon 2> will occur.
Conditions With all conditions met, subsystems not started or MPs are blocked.
(a) The RAID450 DKCMAIN micro-program version is 21-07-04-00/00 or later
(b) In the SM module location “SM00”, DKC-F460I-S1024 DIMM installed. (Not configuration
information, but hardware installation state)
(c) DKCMAIN versions of micro-program stored in SM and that stored in FM are different. (*1)
(d) SM non-volatile
*1: With all the following conditions met, the versions are different
(c-1) Fibre Channel CHA PCB
(c-2) Perform Online micro-FC while Mode 161 is OFF
(c-3) After micro-FC, the CHA PCB not replaced or installed
(c-4) After micro-FC, PS/OFF not performed
Category CHT
Changed DKCMAIN

(2) Storage Navigator Authentication Rejected


Item Description
Contents When accessing a subsystem using Storage Navigator, authentication rejected and access failed.
Conditions The problem occurs with SVP version: 21-14-18-00/00 or higher and only specifying a specific
IP address using Internet Explorer
Category SVP
Changed SVP

(3) Failure Threshold Value Failed to be cleared after FSW Replacement


Item Description
Contents Failure threshold value failed to clear after FSW replacement and SIM reoccurred.
Conditions The problem occurs with the following conditions met.
1. HDD failure occurs when the Today threshold value is exceeded
2. Replacing a FSW connected to a DKA other than DKA-1A
Category SVP
Changed SVP

HDS Confidential 1of 1