Sunteți pe pagina 1din 11

ROOFING

ROOF FOILS ROOF FOILS


2 MASTERPLAST GROUP INTERNATIONAL MASTERPLAST GROUP INTERNATIONAL 3

Ventilation
APPLICATION OF UNDERLAYS
This summary provides a short description of roof underlays sold by Masterplast Group to find the most appropriate In case of pitched roofs, the adequate roof construction has to be built
solutions for different fields of application. Our company offer a wide range of products from traditional non-vapour per-
Non-ventilated (or single-ventilated) Ventilated (or double-ventilated)
meable underlays to vapour-permeable membranes manufactured with the newest technology and also vapour control
1. ventillation air layer 1. ventillation air layer 2. ventillation
layers used. The most important rules of planning and construction are summarized below. Since all variations of end- TILE TILE air layer
using of the products can not be anticipated, the designer/end-user's responsibility to make sure of the suitability of this 50 mm counter batten thermal 50 mm counter batten thermal
underlay for particular purposes. This summary does not substitute the application guidelines and technical datasheets insulation insulation

of these products issued by MASTERPLAST GROUP INTERNATIONAL. vapour permeable


vapour permeable
underlay underlay

Resistance to water penetration tile batten additional


slat frame
tile batten additional
slat frame

R
R

U
U
vapour vapour

O
O

E
E
controll controll

P
The most important function of roof underlays is to drain the wetness - that appears under the roofing – to the eaves so

A
A

C
C
layer layer

V
V
protect the structures and spaces as a secondary water shedding layer from the negative effects of wetness. Most of the

A
A
grooved fixing item grooved fixing item

SP
SP
roofing materials do not provide waterproof covering, as an effect of strong wind, showers or in the form of snow-dust, a gypsum gypsum
plasterboard plasterboard
part of the moisture penetrates under the roofing. Underlays also protect against the condensed water dripping from the

ER
ER
inside surface of the roofing. The smaller the pitch, the longer the way of the water and the more complex the roof forms,

N
N
the higher the risk of soaking is. There are also significant differences among the water resistance of the roofing materials.

IN
IN
The proper underlay covering should be chosen considering all the above-mentioned factors. The simplest and most
inexpensive solution is the application of underlays, which may be laid over rafters and allowed to drape slightly (unsup-
ported) or laid over thermal insulation or timber boarding (supported). In case of a non-ventilated (or single ventilated) roof In case of ventilated (or double ventilated) roof, there
Underlays can be categorized according to their resistance to water penetration. There are three different product catego- structure, the air movement is restricted to between the are two airing gap in the structure. The upper gap is
ries: classified as resistant to water penetration Class W1 (no water penetration – according to EN 1928); Class W2 roofing and the underlay by the counter battens. The between the underlay and the roofing. The role of this
(maximum 100 ml water passing through, according to EN 13111) – these underlays may only be applied on pitched roofs role of this gap is to create an effective drainage path gap is to create an effective drainage path for the wet-
over 25°; and Class W3 (more than 100 ml water passing through) – these products are not applicable as underlay, only for the wetness that appears under the roofing to be ness that appears under the roofing. The other gap
on vertical surfaces (in walls). drained to the eaves or to be ventilated towards the (between the underlay and the thermal insulation) is
In case of each roofing material, the application guideline determines the minimum required pitch of the roof with ridge. Furthermore, the here streaming air is cooling necessary, because in this case the underlay is non-
unsupported, supported and sealed (with integral adhesive tape laid over timber boarding) application of underlay. The the hot roof covering on the backside in summer, thus vapour-permeable (Sd>0.3 m). In winter, the vapour -
table below contains the most frequent cases, for more details see the application guideline. also reducing the heat-load of the built-in spaces in the coming from the heated inner space - condense as it
roof and the aging of the underlay. In winter, this effect reaches the surface of the cold underlay, but the up-
prevents the fast melting of the snow on the roof and moving air ventilates this condensed water to the ridge,
Built in roof Built in roof the development of ice-crests by the eaves. thus preventing it from dropping back.
Type of roofing Type of underlay Empty with with
In non-ventilated pitched roof, vapour In case of non-vapour permeable underlay
covering loft1 simple roof complex
form2 roof form3 permeable (Sd<0.3 m) but watertight (Class W1) (Sd>0.3 m), only this ventilated structure is
underlays must be used. allowed. In case of built-in roof, each rafter space
Plain roof tile with side groove Unsupported application 20 ° 35 ° 40 ° In case of built-in spaces in the roof, this solution is must be properly ventilated from the eaves to the
and single overlap (e.g. straight Supported application 15 ° 15 ° 20 ° recommended, because of the more simple construc- ridge and the underlay is not allowed to contact
or round cutted tile with groove) Sealed application 10 ° 10 ° 15 ° tion and energetic reasons (the underlay protects the the insulation!
thermal insulation from the cooling effects of the air This solution makes possible only simple roof forms
Plain roof tile without side Unsupported application 20 ° 30 ° 35 ° movement) and requires precise construction. Because of the cool-
groove and double overlap Supported application 15 ° 15 ° 20 ° For the proper working of the roof structure, there ing effect of ventilation, the effective thermal resistance
(e.g. beaver tile) Sealed application 10 ° 10 ° 15 °
should be free ventilating gap minimum 200 cm2/m of the insulation decreases by ~25-30% . For the
along the eaves, minimum 50 cm2/m at the ridge, and proper working of the roof structure, there should be
Tile or concrete tile with Unsupported application 18 ° 22 ° 26 °
side groove or with groove Supported application 15 ° 15 ° 15 °
5 cm thick counter batten fixed along the rafters for here also free ventilating gap minimum 200 cm2/m
on wave top Sealed application 10 ° 10 ° 10 ° the gap (For more information see the application along the eaves, minimum 50 cm2/m at the ridge, and
guideline.) minimum 2 cm-thick free airspace between the foil and
Waterproof bituminous Unsupported application Not necessary 20 ° 25 ° the heat insulation.
shingle with double Supported application Not necessary 15 ° 15 °
overlap4 (mechanically fixed Sealed application Not necessary 15 ° 15 ° If it is possible, ventilated (or double ventilated) roof structure should be avoided in residence and office buildings, the
through the underlay) application of vapour permeable underlay is a much safer solution.

1
Empty loft: there is not built-in space under the roof, the thermal insulation is laid on the slab and not moisture-sensitive.
2
Simple roof form: max 10m rafter length, without jointed roof-windows, etc.
3
Complex roof form: valleys on the roof, length ot rafters are over 10 m.
4
Shingle: in case of high density mineral-wool thermal insulation and when the roof structure is properly ventilated, the given
values can be modified (on the basis of the manufacturer’s application guideline).
ROOF FOILS ROOF FOILS
4 MASTERPLAST GROUP INTERNATIONAL MASTERPLAST GROUP INTERNATIONAL 5

Vapour controlling Individual ventilation of halls: Length of roof-plane in m Free venting at


6 °≤α<15 15 °≤α ridge cm2/fm
The temperature in winter is always higher in the living space than outdoors, that causes higher vapour-pressure.
Depending on the function of the rooms, in a family house the vapour pressure can be 1400-1600 Pa higher in the inner
space than outdoors. Due to the difference in vapour-pressure, the vapour tries to diffuse through the structure. Minimum 35mm high trapezoidal plate,
In each case, a vapour control layer has to be mounted on the inner side of the heat insulation thus preventing that contact with foil max. 50% 10 15 200
vapour get into the heat insulation. In heated rooms, in offices vapour control layer (Sd >min 2 m) should be built in. In
Minimum 45mm high trapezoidal plate,
case of wet rooms of apartments (e.g. kitchen, bathroom) minimum Sd>10 m vapour control layer is necessary. In
contact with foil max. 50% 15 20 250
spaces with permanently high vapour pressure (e.g. factory kitchens, laundries, swimming pools, etc.) vapour barrier
(Sd>100 m) must be used.
The vapour control layers should always be placed at the inner side of the heat insulation, its extensions and joints to
other structures (dormer window, walls) should be tight, sealed on air- and vapour-proof way.
Beyond the insulation between the rafters, a supplementary thermal insulation layer should be applied at inner side of GENERAL INSTALLATION GUIDELINES
the rafters. Its thickness is offered to be at least 1/3 part of that between the rafters, but of it is recommended. Mineral
wool insulation materials, jointed without any gaps are the best for this purpose. • The direct UV-radiation damages and destroys the material of the underlays, so they are recommended to be
covered by the roofing as soon as possible. Details must be also carefully and fully-covered finished, that the
underlay not to be exposed to continuous UV-radiation.
Heat protection • Underlays ensure adequate water-tightness only together with the roofing, but without it, these membranes
can not protect (except some sealed underlays made for support and for a limited period), because water can
Underlays do not have significant thermal resistance, reduction of the heat-load of the built-in spaces depends on the
penetrate through the overlappings by the wind.
correct thermal insulation and adequate ventilating. But some metalised underlays can significantly reduce the heat-
• In pitched roof structures, when α< 25°, only underlays Class W1 are allowed to be used. Membranes are
load in summer. These membranes can reflect a great part of the radiated heat by adequate ventilation.
made for boarding should be Class W1, independently of the pitch of the roof.
The vapour-control layer can be heat-reflecting as well, but in this case an airspace is necessary between the meta-
• In case of pitch less, than 25°, the overlapping is minimum 15 cm, except sealed underlay where 10 cm
lised foil and the internal linings (e.g.: plasterboard).
overlapping is enough.
• Although these products have high tensile strength, they cannot resist extreme wind-loads, without the protec-
Durability tion of the roofing. Damages of the underlays caused by wind, hail, etc., are the constructor’s responsibility
– that is why it is so important to be finished the roofing as soon as possible.
The high temperature and heat-load accelerates the ageing of the underlay. Under metal covering or dark, bituminous • Both supported and unsupported underlay should be laid parallel to the eaves with the proper overlapping.
corrugated sheets, in case of complicated roof form with not proper ventilation, this process could be much faster and • The unsupported underlay should be laid with slight, ~2 cm deep free-hanging, while the supported mem-
the earlier damage of the material is expected. branes should be laid free of wrinkles.
The solution is the choosing of the proper structure and material. When the membrane exposed to higher heat-load, • The drainage path between the underlay and the roofing should be constructed in full length of each rafter
an underlay with higher heat-resistance should be applied. The heat-resistance of the underlay is given in the techni- space.
cal datasheets. • Always vapour-permeable underlays must be used over timber boarding.
Our suggestions to determine the adequate underlay to roofings with different heat-load: • The membranes should be fixed by counter-battens, temporary fixing (e.g. by clips) is only allowed under the
line of the counter-batten.
• Lengthening of the underlays is possible over the rafters, under the counter-batten.
NORMAL INCREASED HIGH EXTREME
HEAT-LOAD: HEAT-LOAD: HEAT-LOAD: HEAT-LOAD: • Underlay with adequate heat-resistance according to the expected heat-load should be chosen in order to
In case In case In case of halls, In case of hall ensure long life safety.
of adequately of adequately covered with light covered with dark • Damaging of the membrane should be avoided during construction. Before roofing it must be checked and
ventilated tiling ventilated metal profiled steel, when profiled steel, when repaired when it is necessary.
or shingle made plate, sheet or the special require- the special require- • Eaves water dropping strip should be led out under the counter-batten behind the eaves and not into the gut-
on boarding. bitumen ments of the individu- ments of the individu- ter (because in winter, when the gutter is full of snow, the way of ventilation is closed.)
corrugated al ventilation deter- al ventilation deter-
sheet. mined for hall struc- mined for hall struc-
tures are fulfilled.** tures are fulfilled.**
CONSTRUCTION RULES OF NON-VENTILATED
(OR SINGLE-VENTILATED) STRUCTURES
• Only vapour-permeable membranes (Sd < 0.3 m) may be used as underlays.
70 °C 80-90 °C 100 °C 100 °C* • These membranes can be laid directly on support (timber boarding, thermal insulation).
• The underlay may be folded over the ridge.
• The membrane must be laid continuously, without any gap in the valley.
* Underlays can resist 100 °C heat-load only for a limited period, ~ 5-10 years.

**Since in metal halls the proper ventilation can be ensured only by expensive accessories, special rules
must be kept and the application of an underlay with high heat-resistance is important.
ROOF FOILS ROOF FOILS
6 MASTERPLAST GROUP INTERNATIONAL MASTERPLAST GROUP INTERNATIONAL 7

DUO
Material: 2-layer vapour-permeable underlay (a special, vapour-permeable and watertight
coating on PP layer) with increased heat-resistance.
Application: In pitched roof structures, laid directly onto the thermal insulation.

Technical data:
Unit weight: 140 g/m2 Tensile strength (MD/XD): 190/140N/50mm
Sd: 0.08 m UV-resistance: 3 months
Water-tightness: W1 Temperature resistance: –20 – +90 °C

Available Code
2
MASTERMAX DUO 1.5 m × 50 m=75 m /roll 0201-14015075

–20 °C-
+90 °C

3 ECO

Material: 3-layer vapour-permeable underlay (a vapour-permeable, watertight functional


membrane between 2 layers of non-woven PP).
Application: In pitched roof structures, laid directly onto the thermal insulation.

Technical data:
Weight: 100g/m2 Tensile strength (MD/XD): 170/130N/50mm
Sd: 0.05 m UV resistance: 3 months
Water-tightness: W1 Temperature resistance: –20 °C – +70 °C

Available Code
MASTERMAX 3 ECO 1.5 m × 50 fm=75 m2/roll 0202-10015A75

-20 °C-
+70 °C
Icons Protected against rain Technical datasheet

CE marking Temperature resistance


3 CLASSIC
Protected against atmospheric
exposure, especially sun-radiation Resistance to water penetration or Material: 3-layer vapour-permeable underlay (a vapour-permeable, watertight
water-tightness (Class W1)
and other heat sources functional membrane between 2 layers of non-woven PP),
Resistance to water penetration or Application: In pitched roof structures, laid directly onto the thermal insulation.
UV resistance
water-tightness (Class W2)
Unsupported or ventilated (freely-hanged under- Technical data:
Instruction guideline lay or laid with a ventilation air gap between the Weight: 120 g/m2 Tensile strength (MD/XD): 190/160N/50 mm
underlay and the thermal insulation) Sd: 0.05 m Time for covering: 3 months
Application temperature Supported (laid directly onto timber boarding) Impermeability: W1 Temperature resistance: –20 °C – +70 °C
(during installation)

Fragile Supported (laid directly onto the


thermal insulation) Available Code
2
MASTERMAX 3 CLASSIC 1.5 m × 50 m=75 m /roll 0202-12015A75

–20 °C–
+70 °C
ROOF FOILS ROOF FOILS
8 MASTERPLAST GROUP INTERNATIONAL MASTERPLAST GROUP INTERNATIONAL 9

3 CLASSIC SA 3 PRO
(with self adhesive tape)
Material: 3-layer vapour-permeable underlay (a vapour-permeable, water- Material: 3-layer vapour-permeable underlay (a vapour-permeable, watertight func-
tight functional membrane between 2 layers of non-woven PP) with 5 cm- tional membrane between 2 layers of PES) with increased heat-resistance.
wide self-adhesive strip. Application: In pitched roof structures, laid directly onto the thermal insulation or
Application: In pitched roof structures, laid directly onto the thermal insula- timber boarding.
tion with a wind-tight sealing by the self-adhesive strip. Technical data:
Technical data: Weight: 130 g/m2 Tensile strength (MD/XD): 350/270 N/50mm
Weight: 120g/m2 Tensile strength (MD/XD): 190/160N/50mm Sd: 0.02m UV resistance: 4 months
Sd: 0.05 m UV resistance: 3 months Watertightness: W1 Temperature resistance: –40°C – +100 °C
Water-tightness: W1 Temperature resistance: -20 °C – +70 °C Reaction to fire: Euroclass E Packaging: 24 rolls/pallet
Reaction to fire: Euroclass E

Available Code
Available Code
MASTERMAX 3 PRO 1.5 m × 50=75 m2/roll 0202-13015075
MASTERMAX 3 CLASSIC SA 1.5 m × 50 fm=75 m2/roll 0202-12015SA0

-40 °C-
-20 °C- +100 °C
+70 °C
THERMO SA
3 TOP
Material: 3-layer vapour-permeable underlay (a special, vapour-permeable and water-
Material: 3-layer vapour-permeable underlay (a vapour-permeable, water- tight coating on PES layer) with self-adhesive strips (6cm from the edge on the top and
tight functional membrane between 2 layers of non-woven PP), 4cm from the edge on the bottom) and extremly high heat-resistance.
Application: In pitched roof structures, laid directly onto the thermal insula- Application: In pitched roof structures, used especially under metal roofing or in case
tion or timber boarding. of extreme heat-load, laid directly onto the thermal insulation.
Technical data: Technical data:
Weight: 140g/m2 Tensile strength (MD/XD): 240/170N/50mm Weight: 210 g/m2 Its tensile strength cross/length: 440/270N/50 mm
Sd: 0.04 m UV resistance: 3 months Sd: 0.1 m UV resistance: 12 months
Water-tightness: W1 Temperature resistance: –20 °C – +70 °C Watertightness: W1 Temperature resistance: –20°C – +150°C
Reaction to fire: Euroclass E Reaction to fire: Euroclass E Packaging: 24 rolls / pallet

Available Code Available Code


2
MASTERMAX 3 TOP 1.5 m × 50 fm=75 m2/roll 0202-14015A75 MASTERMAX THERMO SA 1.5 m × 50=75 m /roll 0202-02SA5075

-20 °C- -40 °C-


+70 °C +150 °C

3 EXTRA ALU
Material: 3-layer vapour-permeable underlay (a vapour-permeable, water-
tight functional membrane between 2 layers of non-woven PP), Material: 4-layer vapour-permeable underlay (vapour-permeable, watertight mem-
Application: In pitched roof structures, laid directly onto the thermal insula- brane with a special, perforated, heat-reflecting layer on the top)
tion or timber boarding. Application: In pitched roof structures, laid directly onto the thermal insulation.
Technical data: Technical data:
Weight: 160 g/m2 Tensile strength (MD/XD): 270/170N/50 mm Weight: 200g/m2
Sd: 0,02 m UV resistance: 3 months Tensile strength (MD/XD): 300/240N/50mm Sd: 0.05 m
Water-tightness: W1 Temperature resistance: –20 °C – +70 °C UV resistance: 4 months Water-tightness: W1
Reaction to fire: Euroclass E Temperature resistance: –20 °C – +70 °C

Available Code Available Code


2 MASTERMAX ALU 1.5 m × 50 m=75 m/roll 0202-03015075
MASTERMAX 3 EXTRA 1.5 m × 50 m=75 m /roll 0202-16015A75

-20 °C- –20 °C-


+70 °C +70 °C
ROOF FOILS ROOF FOILS
10 MASTERPLAST GROUP INTERNATIONAL MASTERPLAST GROUP INTERNATIONAL 11

Metal SOFT-S MP

Material: Vapour-permeable, 4-layer roofing foil (vapour-permeable, watertight


membrane between 2 layers of PP, bonded to an open mesh of PP strands Material: 2 layers of yellow or white polyethylene with polyethylene mesh rein-
Application: In pitched roof structures over 10° on timber boarding, under flat, forcement and microperforation, with higher unit weight and mechanical strength.
rigid sheet metal cladding (zinc, copper, stainless steel). Application: perforated underlay for ventilated pitched roofs (α>min. 20), without
support and with normal heat-load.
Technical data:
Weight: 500 g/m2 Sd: 0.03 m
UV resistance: 3 months Water-tightness: W1
Available Code
Temperature resistance: –20 °C – +70 °C
MASTERFOL® SOFT-S MP-W 1.5 m × 50 fm=75 m2/roll 0210-1W015000
Available Code MASTERFOL® SOFT-S MP-Y 1.5 m × 50 fm=75 m2/roll 0210-1Y015000
MASTERMAX Metal 1.5 m × 25 m=37.5 m2/roll 0202-04015037

+40 °C
–20 °C-
+70 °C

SOFT MP SOFT ALU

Material: 2 layers of yellow or white polyethylene with polyethylene mesh rein- Material: Polyethylene underlay with polyethylene mesh reinforcement and metal-
forcement and microperforation. ized surface.
Application: perforated underlay for ventilated pitched roofs (α>min. 25), without Application: non-vapour permeable underlay for ventilated pitched roofs ( >min.
support and with normal heat-load. 20), without support and with normal heat-load. It is also used as a vapour-barrier,
installed behind the internal lining (e.g. plasterboard).

Available Code
Available Code
MASTERFOL® SOFT MP-W 1.5 m × 50 fm=75 m2/roll 0210-0W015000
MASTERFOL® SOFT ALU 1.5 m × 50 fm=75 m2/roll 0207-01015050
MASTERFOL® SOFT MP-Y 1.5 m × 50 fm=75 m2/roll 0210-0Y015000

+70 °C
+40 °C

SOFT W BLUE Sd20


non-perforated
Material: PE vapour control layer with ageing- and fire-retardent additives.
Material: 2 layers of white polyethylene with polyethylene mesh reinforcement.
Application: Installed behind the internal lining (e.g. plasterboard), it minimises the
Application: non-perforated underlay for ventilated pitched roofs (α>min. 20), with-
passage of vapour through the structure meanwhile reduces the air-infiltration and heat
out support and with normal heat-load.
losses (in case of tight sealing by overlappings and jointings).

Technical data:
Thickness: 0.2 mm
Available Code Sd: 20 ms
MASTERFOL® SOFT W 1.5 m × 50 fm=75 m2/roll 0210-0W115000
Available Code

MASTERFOL BLUE Sd20 1.5 m × 50 fm=75 m2/roll 0214-00015000

+40 °C
ROOF FOILS ROOF FOILS
12 MASTERPLAST GROUP INTERNATIONAL MASTERPLAST GROUP INTERNATIONAL 13

Adhesive tapes for roofing foils ALU


Material: Polythylene fabric with heat-reflecting aluminium layer.
MASTERMAX® TAPE (Diffusion tape): For the single-side taping of vapour-permeable Application: underlay for ventilated pitched roofs (α>min. 20), without support and
roofing foils and repair of tears. with increased heat-load. It is also used as a vapour-barrier, installed behind the inter-
MASTERFOL® TAPE-1 (Single-sided tape): For the single-side taping of non-vapour nal lining (e.g. plasterboard).
permeable underlays and for repair of tears.
MASTERFOL® TAPE-2 (Double-sided tape): For taping the edges of roofing foils to
each other, to drop plates or to other metal structures.
Available Code
® 2
ISOFLEX ALU 1.2 m × 50 fm=60 m /roll 0208-00012050
ISOFLEX® ALU 1.5 m × 50 fm=75 m2/roll 0208-00015050
Ragasztószalag Rollszélesség Rollhossz Code
®
MASTERMAX TAPE 50 mm 25 m 0213-02050025
MASTERMAX® TAPE 75 50 mm 25 m 0213-02075025
MASTERFOL® TAPE 1 50 mm 25 m 0213-03050025 +90 °C 0 °C-
MASTERFOL® TAPE 2 20 mm 25 m 0213-04020025 +90 °C

ALU-LP

SOFT Material: Polyethylene air-bubble foil with metalized Polypropylene.


Application: underlay for ventilated pitched roofs (α>min. 20), without support and
with normal heat-load. It is also used as a vapour-barrier, installed behind the inter-
Material: Polyethylene fabric with a special watertight coating and high mechanical nal lining (e.g. plasterboard).
resistance.
Application: underlay for ventilated pitched roofs (α>min. 20), without support and
with normal heat-load.
Available Code
® 2
ISOFLEX ALU-LP 1.2 m × 50 fm=60 m /roll 0211-01000060

Available Code

ISOFLEX® SOFT 1.5 m × 50 fm=75 m2/roll 0206-00015000


+70 °C -10 °C-
+70 °C

+70 °C

ALU-PZ
SOFT-S
Material: Metalised Polyethylene
Application: Installed behind the internal lining (e.g. plasterboard), it minimises
Material: Polyethylene fabric with a special watertight coating, with even higher the passage of vapour through the structure meanwhile reduces the air-infiltration
unit weight and mechanical strength. and heat losses (in case of tight sealing by overlappings and jointings).
Application: underlay for ventilated pitched roofs (α>min. 20), without support and
with normal heat-load.
Available Code

ISOFLEX® ALU-PZ 1.2 m × 50 fm=60 m2/roll 0212-01000060


Available Code

ISOFLEX® SOFT-S 1.5 m × 50 fm=75 m2/roll 0206-10015000

-10 °C-
+40 °C

+70 °C
ROOF FOILS ROOF FOILS
14 MASTERPLAST GROUP INTERNATIONAL MASTERPLAST GROUP INTERNATIONAL 15

TAPE
TYVEK® Soft
Adhesive tape with aluminium reflecting surface: for the air- and vapour-tight
jointing of vapour-barrier layers. Material: Vapour-permeable underlay, made of HDPE.
Application: In pitched roof structures without support or laid directly onto
the thermal insulation

Available Code Technical data:


®
ISOFLEX TAPE 50 5 cm × 50 fm/roll 0213-01050050 Weight: 60 g/m2
Tensile strength (MD/XD): 165/140N/50mm
Sd: 0.02 m
UV resistance: 4 months
Water-tightness: W1
Temperature resistance: –40 °C – +100 °C
SOLFLEX breathing

Material: Non-woven PP based underlay with heat-reflecting and perforated, meta-


lised surface.
Application: Vapour-permeable underlay laid directly onto the thermal insulation, Available Code
in case of a strong (min. Sd=25m) vapour-barrier layer inside.
TYVEK® Soft 1.5 m × 50 fm=75 m2/roll 0203-21000075

Available Code

SOLFLEX 1.2 m × 41,67 fm=50 m2/roll 0204-00000050


-40 °C–
+100 °C

TYVEK® Solid

TYVEK® SD2 VCL


Material: Vapour-permeable underlay, made of HDPE
Material: Vapour-control layer (made of Polypropylene and Ethylen-Butylacrylate Copolymer) Application: In pitched roof structures without support or laid directly onto the thermal
Application: Installed behind the internal lining (e.g. plasterboard), it minimises the pas- insulation or timber boarding.
sage of vapour through the structure meanwhile reduces the air-infiltration and heat losses
(in case of tight sealing by overlappings and jointings). Technical data:
Technical data: Weight: 80 g/m2
Weight: 105 g/m2 Sd: 2– 4 m Tensile strength (MD/XD): 245/215N/50mm
Application temperature: –10°C – +40°C Sd: 0.03 m
UV resistance: 4 months
Available Code
Water-tightness: W1
® 2
TYVEK SD2 VCL 1.5 m × 50 fm=75 m 0203-50750075 Temperature resistance: –40 °C – +100 °C

Available Code
®
TYVEK adhesive tape
TYVEK® Solid 1.5 m × 50 fm=75 m2/roll 0203-20000075

Material: Polyethylene tape with modified acrylic-base adhesive


Application: For the single-side taping of vapour-permeable roofing foils and for the
repairing of tears.
–40 °C–
Available Code +100 °C
TYVEK® adhesive tape in rolls: 75 mm × 25 m 0203-90075025
ROOF FOILS ROOF ACCESSORIES
16 MASTERPLAST GROUP INTERNATIONAL MASTERPLAST GROUP INTERNATIONAL 17

TYVEK® Pro and


TYVEK® Pro with adhesive tape
ROOF ACCESSORIES
The modern roofing materials (clay- and concrete tiles, shingles, metal sheets, etc.) together with their appropriate accessories create
systems and so fulfil the requirements of a modern roof structures.
Material: 2-layer vapour-permeable underlay, (laminate of HDPE + PP mechanical protection) Due to the great variety of roof covering materials, the extensive range of forms and sizes, a wide selection of roof accessories is avail-
Application: In pitched roof structures without support or laid directly onto the thermal insula- able. There are products universally applicable to several covering materials and there are some that fit only one or some types.
tion or timber boarding with sealed overlapping on a wind-tight way.
Major groups of roof accessories sold by our company:
Technical data: • Ventilating accessories
Weight: 125 g/m2 • Clamps, fastenings, safety elements
Tensile strength (MD/XD): 265/230N/50mm • Accessories for tinner works, sealings
Sd: 0.02 m • Other accessories
UV resistance: 4 months
Water-tightness: W1
Ventilating accessories:
Temperature resistance: –40 °C – +100 °C
The proper ventilation of the pitched roof structure is necessary (see the relevant guideline of ÉMSZ and Application Guideline of
Underlays - Masterplast Group International). Ventilating must be continuous between the eaves and ridge - as much as it possible.
Fresh, colder air must be ensured by the eaves, that moving up between the counter battens and transports the moisture appear-
ing under the roofing to the ridge where it ventilates out. Furthermore, the here streaming air is cooling the hot roof covering on
the backside in summer, thus also reducing the heat-load of the built-in spaces in the roof and the aging of the underlay.
Available Code Conditions of the proper ventilation are defined by standards, guidelines (see: Application Guideline of Underlays - Masterplast
Group International). In case of a normal pitched roof (α>20°, length of rafters is maximum 10 m, with tile roofing), the minimal free
TYVEK® Pro 1.5 m × 50 fm=75 m2 0203-40000075
ventilating cross-section is along the eaves: 200 cm2/m, while along the ridge is: 50 cm2/m.
TYVEK® Pro with adhesive tape 1.5 m × 50 fm=75 m2 0203-41000075 The necessary free ventilating cross-section can be ensured more efficiently by the accessories, than e.g. with ventilating tiles. These
tiles generally have smaller free cross-section, so 2–3 pieces of them would be necessary among each rafters. Application of roof
accessories is much cheaper, more efficient, and aesthetic, while prevent birds and large insects from getting beneath the roofing.
-40 °C–
+100 °C Clamps, fastenings, safety elements:
In many cases, the roofing tiles do not have to be individually fastened, but in case of certain pitches and details, their fastening
may become necessary (according to the application rules of the manufacturers of roof covering). However, ridge tiles must be
always fastened and Masterplast offers clamps for numerous ridge tiles.
Masterplast also offers the most frequently used snow guides, which prevents from the sudden sliding of snow, thus avoiding per-
sonal injuries and damages. The appropriate place and number of snow guides depends on the type of roof covering material, on the
TYVEK® Metal shape of the roof, as well as on the height of the building (according to the application rules of the manufacturers of roof covering).

Metal accessories, attachments:


Material: 3-layer vapour-permeable underlay (laminate of vapour-permeable, water- During the construction of high pitched roofs, one often comes across the organizational problem of different professions having
tight LDPE and PP, bonded to an open mesh of PP strands) to work in unison or following one another in fast succession (carpenter, roofer, tinker). Masterplast offers several practical acces-
Application: In pitched roof structures over 10° on timber boarding, under flat, rigid sories that can be installed by the carpenter or the roofer if necessary, with a minimal tool demand, and there is no need to wait
for the tinker to finish his job. Thus faster, simpler and cheaper work is promoted.
sheet metal cladding (zinc, copper, stainless steel).
Metal accessories facilitate the work of tinkers as well, especially in the case of high curvature tiles of a wavy design, where attach-
ments are established easier and faster with highly-mouldable accessories than by traditional methods.
Technical data:
Weight: 407 g/m2 Accessories for tinner works, sealings
Sd: 0.02 m In many cases during the construction of pitched roofs, different professions have to work just after each other (carpenter, tinker,
UV resistance: 2 weeks roofer). Masterplast offers several practical accessories that can be installed by the carpenter or the roofer and so there is no need
Water-tightness: W1 to wait for the tinker – it makes the finishing of the works faster and cheaper, but these accessories accelerate the work of tinkers
Temperature resistance: –40°C – +100°C as well.
Other accessories
This group of products includes ventilating window, sun tile, ventilating or base tile, aerial’s adapter, ventilating chimney, etc.

Available Code

TYVEK® Metal 1.1 m × 30 fm=33 m2 0203-30000033

–40 °C–
+100 °C
Protected against rain Fragile

Protected against atmospheric exposure, espe-


cially sun-radiation and other heat sources
ROOF ACCESSORIES ROOF ACCESSORIES
18 MASTERPLAST GROUP INTERNATIONAL MASTERPLAST GROUP INTERNATIONAL 19

AC Perforated ventilating
AC Eaves Comb band/ventilating mesh

Made of PVC Made of PP, UV-resistant


Size: length 1000 mm. Size: length 5 m
Application: used to prevent birds and large insects from getting beneath the roof- Application: used to prevent birds and large insects from getting beneath the roofing
ing (between the tile batten and the wave of the tile) (between underlay and the first tile batten)
Free ventilating cross-section: approx. 70%. Free ventilating cross-section: perforated airing band: 70%, ventilating mesh: 80%

Eaves comb Red Brown Black Perforated airing band Code


Available: in rolls, 10cm×5m/roll Brown 0302-00100BR0
Code: 0301-00100RE0 0301-00100BR0 0301-00100BK0 Black 0302-00100BK0
Red 0302-00100RE0
White 0302-00100WH0
In rolls, 5cm×5m/roll Brown 0302-00050BR0
Black 0302-00050BK0
Red 0302-00050RE0
White 0302-00050WH0
Ventilating mesh
AC Eaves comb Available: in rolls, 10cm×5m/roll Black 0302-00300BK0
with ventilating batten

Made of PVC
Size: length 1000 mm, height of ventilating batten: 25 mm
Application: used to prevent birds and large insects from getting beneath the roofing
AC Perforated
(between the tile batten and the wave of the tile) and ensures more ventilation by ventilating profile
the ventilating batten.
Free ventilating cross-section: minimum 220 cm2/m (across the batten) + approx. 70%. Made of PP, UV-resistant
Size: length 2.5 m
Application: used to prevent birds and large insects from getting beneath the roofing
(between underlay and the first tile batten)
Free ventilating cross-section: 70%,
Eaves comb with ventilating batten Red Brown Black
Perforated PVC airing profile Available Code
Code: 0301-00200RE0 0301-00200BR0 0301-00200BK0 Brown 2.5 m/pcs 0319-00250BR0
Black 2.5 m/pcs 0319-00250BK0
Red 2.5 m/pcs 0319-00250RE0

AC Rigid ridge
AC Airing batten ventilating profile
Made of PVC, UV-resistant
Application: Ensures free ventilation under the ridge tiles of the below mentioned types.
Size: length 1000 mm, height: 25 mm
Types: Alpine/Altec 2.2 pcs/m;
Application: used instead of the first tile batten by the eaves, ensures proper ventilation.
Roman/Danubia 2.2 pcs/m;
Free ventilating cross-section: minimum 220 cm2/m
Csornai 1.1 pcs/m
Free ventilating cross-section: 125 cm2/m/roof side

Airing batten Red Black

Dry crest part: Red Brown Anthracite Grey


Code: 0319-10100RE0 0319-10100BK0
Altek Alpine 0320-00100RE0 0320-00100BR0 0320-00100AN0 0320-00100GY0
Roman 0320-00200RE0 0320-00200BR0 0320-00200AN0 0320-00200GY0
Csornai 0320-00300RE0 – – –
ROOF ACCESSORIES ROOF ACCESSORIES
20 MASTERPLAST GROUP INTERNATIONAL MASTERPLAST GROUP INTERNATIONAL 21

AC Shingle ridge vent AC Crest tile

Material: made of PVC, black


Material: made of aluminium lacquered with polyester paint
Size: length 1.0m
Application: used for ridge tile installation along the ridges and hips.
Application: used for the ridge ventilation of shingle roofs, fixing by nails and covered
with bitumen shingles.
Free ventilating cross-section: 50 m2/m/roof plane with sealing sponge band,
Ridge tile clamp 8012 Red Brick red Green Brown Anthracite Grey Pottery red
125 cm2/m/roof plane without sealing sponge band.
For concrete tile 0308-01000012 0308-01000BRE 0308-01000GR0 0308-01000BR0 0308-01000AN0 0308-01000GY0 –
50 pcs/box

Available Code For Tondach ridge tile with groove


40 pcs/box – 0308-00200BRE – – – – 0308-00200TRE
Ridge airing 1m 0314-00100000
For Tondach tile
30 pcs/box – 0308-00300BRE – – – – –

AC Universal seal
AC Shingle vent
Material: coloured Polyurethane foam
Application: it ensures the sealing against wetness under the ridge tiles along the ridges
Painted metal vent and hips. Non-ventilating, so it can be applied together with ventilating tiles or in pithed
Size: 500 × 300 mm (external dimensions) roofs without underlays.
Application : ensure additional ventilation on shingle roofing. Types: height: 50 mm, 60 mm, 75 mm.
Free ventilating cross-section: 42 cm2/pc

Universal arris part Red Brown Anthracite


50/100 mm 0307-00050RE0 ------ --------
60/120 mm 0307-00060RE0 0307-00060BR0 0307-00060AN0
Point vent 8012 Red Green Black
75/150 mm 0307-00075RE0 0307-00075BR0 0307-00075AN0
Code 0314-00000RE0 0314-00000GR0 0314-00000BK0

AC valley seal wedge


coloured Polyurethane foam with self-adhesive tape - triangular
Size: wedge length: 1000 mm
Application: it ensures proper sealing against wetness under the cutted edges
AC End cap of the tiles along the valley. Non-ventilating, so ventilation must be secured
(e.g. by ventilating tiles)

Material: Made of coloured PVC or painted metal


Arris sponge Code
Use: used for covering the end of the ridge instead of starter or ending ridge tiles
Red 0316-00000RE0
Brown 0316-00000BR0
Anthracite 0316-00000AN0

Code Red Brown Anthracite


AC Ridge batten strut
End cap PVC 0303-00000RE0 0303-00000BR0 0303-00000AN0
Made of galvanized steel
End cap metal 0303-00100RE0 0303-00100BR0 0303-00100AN0
Application: Serves for the exact lining and height adjustment of ridge batten, without
reduction of the ventilating cross-section.

Code
Ridge batten support 0325-00000050

S-ar putea să vă placă și