Install Removable Insulation Jackets Benefits:


Often steam traps, valves and controls valves are not insulated or have • Reduce potential personnel hazard
permanent insulation that has been damaged or removed to allow for
routine maintenance, troubleshooting or trap surveys. • Conserve energy by reducing heat loss

Exposed traps and valves pose not only a safety hazard to personnel • Improve the overall plant energy
but also represent a tremendous source of heat loss. Spirax Sarco
efficiency
removable insulation pads are made from a high-quality, flexible and
non-combustible silicone cloth inner liner, 1” thick Tempmat fiberglass
• Prevent or reduce damage to
insulation and Teflon coated fiberglass outer liner. These removable
insulation jackets will provide your organization with a safe and affordable equipment from fire/corrosive
way to reduce energy loss, and increase safety. atmosphere

Applications & Advantages: • Provide additional noise attenuation


Reusable insulation jackets are commonly used in many commercial and
industrial applications with irregular surfaces that are difficult to insulate
using conventional methods or where the insulation is removed at regular
intervals for the purposes of routine maintenance, troubleshooting or
surveys. The pads are extremely flexible, durable, and vibration-resistant
and can be installed on irregular or difficult to access surfaces. All high
temperature equipment, valves, fittings & traps should be insulated to
reduce heat loss, reduce noise & improve safety.

Availability:
Spirax Sarco insulation jackets for standard parts are available in stock.
Please allow 2-3 weeks delivery for orders including large quantities. For
non-standard parts, contact one of our account executives to discuss
custom insulation jacket options.
spiraxsarco.com/ca

Feel the difference B ef o r e A f t er

See the difference!


With a thermal imaging camera you can
see the difference that an insulation
jacket has when applied to a steam trap.

Prior to installation of the insulation jacket, the


steam trap reached an external temperature
of 115°C (indicated by the bright yellow areas
of the image). This trap was hazardous to the
touch, and was producing quite an amount of
heat loss.

With the installation of an insulation jacket the


external temperature was reduced to 27°C (as
indicated by the purple colour on the image).
This trap was now losing considerably less heat,
and more importantly safe to the touch.

Protection from extreme operating temperatures


It’s common in an industrial environment for equipment to frequently face extreme hot or cold. Such extreme
temperatures can lower lifespans of the equipment producing the heat, as well as the equipment nearby. Constant
superheating and cooling is hard on even the toughest machinery and equipment by causing imperceptible
expansion and contraction, which will degrade equipment integrity. Our removable insulation can absorb and
retain heat to help keep temperatures moderate and help your equipment last longer.
I nsula tio n J a c k e ts

r et ur n on inves tme n t
The following table summarizes the energy savings from the use of Spirax Sarco Insulation Jackets for a range of
Spirax Sarco standard parts. These values are calculated using the NAIMA (North American Insulation Manufacturer’s
Association) 3E Plus computer program

Energy savings is defined as the difference in heat loss between the uninsulated item and the insulated item operating
at the same temperature. Energy savings are evaluated at an operating temperature of 300ºF which corresponds to an
operating saturated steam temperature of approximately 50 psig.

Conditions: Ambient Temp. 70˚F Runtime 8,760 hrs/yr

Cost of Steam $12/1,000lbs Ambient Air Speed 0.5 ft/s

Boiler Efficiency 85% Insulation Efficiency 85%

Results: Equipment Size Savings Equipment Size Savings


BTU/Hr $/Year BTU/Hr $/Year
1/2” 534 65.00 1/2” 1310 159.00
FT14
Series LC 3/4” 534 65.00 3/4” 1310 159.00
Steam Trap 1” 786 95.00 1” 1547 187.00
1” 899 109.00 25P Series 1 1/4”” 1610 195.00
FT14 Se- 1 1/4” 899 109.00 Pressure 1 1/2” 1610 195.00
ries Steam Reducing
Trap 1 1/2” 1473 178.00 Valves 2” 2142 259.00
2” 1588 192.00 2 1/2” 2980 361.00
1/2” 562 68.00 3” 3221 390.00

FTI Series 3/4” 562 68.00 4” 4137 501.00


Steam Trap 1” 562 68.00 1/2” 490 59.00
1 1/2” 1600 194.00 3/4” 490 59.00
3/4” 562 68.00 1” 619 75.00
1” 562 68.00 Spiratrol 1 1/4” 779 94.00
FT Series Series
1 1/4” 562 68.00 1 1/2” 863 104.00
Steam Trap Control
1 1/2” 1684 204.00 Valves 2” 1066 129.00
2” 1744 211.00 2 1/2” 1578 191.00
1/2” 488 59.00 3” 2021 254.00

B Series 3/4” B1 488 59.00 4” 3311 401.00


Steam Trap 3/4” B2 596 72.00 2” 359 43.00
1” 907 110.00 M40 Series 2 1/2” 462 56.00
3/4” Ball Valves 3” 633 77.00
2235 270.00
APT10
4” 854 103.00
Automatic 1 1/2”
3600 436.00
Pump Trap APT14
2” APT
3922 475.00
14HC
spiraxsarco.com/ca
S pec i ficat ions
Temperature Limit (Continuous use limit) : 249°C (480°F)
Outer Jacketing: Silicone impregnated fiberglass (17 oz.)
Inner Jacketing: Silicone impregnated fiberglass (17 oz.)

Insulation: 1” thick, 9# density Temp-mat


(APT14, APT14HC, 25P valves, LEA valves, M40- 3” & 4, PTC / PTF, S1 /S2/ S3
Separators)

1.5 “ thick, 9# density Tempmat


(up to 1” SC4 & Flash Vessels)

2” thick, 9# density Tempmat
( 1 1/2” – 12” SC4 separators)

Thread: Teflon coated Fiberglass


Seam Fasteners: Belts with double 304 SS D-rings and/or Velcro Fasteners
Attachment: Draw cord flaps at terminal ends
I.D. Tags: Stainless Steel

Temperature Limit (Continuous use limit) : 287°C (550 °F)


Outer Jacketing: LFP2105 Pure Teflon Laminate - Food Grade Material
Inner Jacketing: LFP2105 Pure Teflon Laminate - Food Grade Material

Insulation: Temp-mat (9# density)

Thread: Pure Teflon Thread
Seam Fasteners: Velcro
Attachment: Drawcord flaps at terminal ends, rainflaps
I.D. Tags: Stainless Steel

Serving a wide range of industries

Foods Brewing and OEM HVAC Pharmaceuticals Healthcare Water Power Rubber and Chemicals Refining and
distilling Machinery treatment generation plastics petrochemical
spiraxsarco.com/ca

Calgary Office Toronto Office Montreal Office


3606 Blackfoot Trail SE 383 Applewood Crescent 660 de laSabliere, Suite 100
Calgary, AB, T2G 4E6 Concord, Ontario, L4K 4J3 Bois-des-Filion, Quebec, J6Z 4T7
T: 403-263-3052 T: 905-660-5510 T: 450-621-3790
F: 403-263-3095 F: 905-660-5503 F: 450-621-8471

Spirax Sarco, Inc.


383 Applewood Crescent, Concord, ON
T 800-883-4411 or 803-714-2000
F 803-714-2222
www.spiraxsarco.com/ca

© Copyright 2015 Spirax Sarco is a registered trademark of Spirax-Sarco Limited