0 evaluări0% au considerat acest document util (0 voturi)
111 vizualizări1 pagină
The document is a checklist for the structural design of a Railway Over Bridge (ROB). It contains 34 items to verify that the design meets various codes and standards for loads, earthquake provisions, welding, connections, and more. Some key points are that the design is approved, meets load standards, has been proof checked, and addresses safety during construction. Signatures and reports are included to confirm the design was properly carried out.
The document is a checklist for the structural design of a Railway Over Bridge (ROB). It contains 34 items to verify that the design meets various codes and standards for loads, earthquake provisions, welding, connections, and more. Some key points are that the design is approved, meets load standards, has been proof checked, and addresses safety during construction. Signatures and reports are included to confirm the design was properly carried out.
The document is a checklist for the structural design of a Railway Over Bridge (ROB). It contains 34 items to verify that the design meets various codes and standards for loads, earthquake provisions, welding, connections, and more. Some key points are that the design is approved, meets load standards, has been proof checked, and addresses safety during construction. Signatures and reports are included to confirm the design was properly carried out.
(Yes/No) 1. Is GAD approved Yes 2. Is maintenance agreement signed * 3. Is supervision agency for ROB work approved by Railway * 4. Is all codal charges including maintenance deposited by Party * 5. Is loading as per IRC standards No 6. Is any deviation from IRC standards, why Metro loading as per DBR 7. Is Earthquake provisions as per IRC Yes, as per IRS 8. IS temperature load provisions as per IRC Yes, as per IRS 9. Is check done for other loadings Yes, as per IRS 10. Is crash barrier as per IRC type NA 11. Is crash barrier designed for IRC loads NA 12. Is cantilever portion of deck slab as per IRC Yes, as per IRS 13. Is welding sequence of SAW welding given No 14. Is connection detailing as per RDSO and design of all Yes connection shown 15. Is shear connectors of stud type Yes 16. Is there any camber in PG No 17. Is Launching Drawing enclosed Yes 18. Is deck slab temp. shuttering drawing enclosed No 19. Is signature of designer on all drawings & all pages of design Yes booklet done 20. Is signature of agency/concessionaire who is executing the * work on all drawings 21. Is signature of owner/NHAI/PWD is done on all drawings * 22. Is proof check done by IIT/NIT's and proof check certificate Yes "The design & drawing is confirming as per latest IRC/MORTH/IRS guidelines for ROB's as on date" endorsed by proof checker 23. Is owner/ agency/ concessionaire undertaking about * responsibility of design and drawing with them, although approved by Railways is enclosed. 24. Is Geo-tech report enclosed * 25. Is pile capacity calculated as per latest codal provisions Yes 26. Is structural Drawing as per GAD Yes 27. If deviation from GAD, reason for the same No 28. Is substructure designed for all loads as per IRC Yes, as per Metro loading 29. Is loads/deformation table for bearing design enclosed Yes 30. Is precaution during working related to train safety and road Yes user safety enclosed 31. Is drawing on original tracing submitted Yes 32. Is the dimensions adopted in design and drawing are Yes matching 33. Is RCC design is confirming IRC & IS 456, IS-1893 codal Yes provisions