Documente Academic
Documente Profesional
Documente Cultură
iA24
iA6
IC-A24 IC-A6
SAFETY TRAINING INFORMATION
Your Icom radio generates RF electromagnetic energy during • DO NOT operate the radio without a proper antenna attached, as this
transmit mode. This radio is designed for and classified as may damage the radio and may also cause you to exceed FCC RF expo-
“Occupational Use Only”, meaning it must be used only dur- sure limits. A proper antenna is the antenna supplied with this radio by
ing the course of employment by individuals aware of the the manufacturer or antenna specifically authorized by the manufacturer
hazards, and the ways to minimize such hazards. This radio for use with this radio.
W ARN ING is NOT intended for use by the “General Population” in an • DO NOT transmit for more than 50% of total radio use time (“50% duty
uncontrolled environment. cycle”). Transmitting more than 50% of the time can cause FCC RF expo-
This radio has been evaluated for compliance at the distance of 2.5 cm with sure compliance requirements to be exceeded. The radio is transmitting
the FCC RF exposure limits for “Occupational Use Only”. In addition, your when “ ” appears on the function display. You can cause the radio to
Icom radio complies with the following Standards and Guidelines with regard transmit by pressing the “PTT” switch.
to RF energy and electromagnetic energy levels and evaluation of such levels • ALWAYS keep the antenna at least 2.5 cm (1 inch) away from the body
for exposure to humans: when transmitting and only use the Icom belt-clips which are listed on
• FCC OET Bulletin 65 Edition 97-01 Supplement C, Evaluating Compli- page 32 when attaching the radio to your belt, etc., to ensure FCC RF
ance with FCC Guidelines for Human Exposure to Radio Frequency exposure compliance requirements are not exceeded. To provide the re-
Electromagnetic Fields. cipients of your transmission the best sound quality, hold the antenna at
• American National Standards Institute (C95.1-1992), IEEE Standard for least 5 cm (2 inches) from your mouth, and slightly off to one side.
Safety Levels with Respect to Human Exposure to Radio Frequency The information listed above provides the user with the information needed to
Electromagnetic Fields, 3 kHz to 300 GHz. make him or her aware of RF exposure, and what to do to assure that this
• A merican National Standards Institute (C95.3-1992), IEEE Recom- radio operates with the FCC RF exposure limits of this radio.
mended Practice for the Measurement of Potentially Hazardous Electro-
magnetic Fields– RF and Microwave. Electromagnetic Interference/Compatibility
• The following accessories are authorized for use with this product. Use of During transmissions, your Icom radio generates RF energy that can possibly
accessories other than those specified may result in RF exposure levels cause interference with other devices or systems. To avoid such interference,
exceeding the FCC requirements for wireless RF exposure.; Belt Clip turn off the radio in areas where signs are posted to do so. DO NOT operate
(MB-86/103), Speaker Microphone (HM-173), Rechargeable Ni-MH Bat- the transmitter in areas that are sensitive to electromagnetic radiation such as
tery Pack (BP-210N) and Alkaline Battery Case (BP-208N). hospitals and blasting sites.
WORD DEFINITION
Personal death, serious injury or an explo-
RDANGER!
sion may occur.
Personal injury, fire hazard or electric shock
RWARNING!
may occur.
CAUTION Equipment damage may occur.
If disregarded, inconvenience only. No risk
NOTE
of personal injury, fire or electric shock.
ii
PRECAUTION
R DANGER! NEVER short the terminals of the battery CAUTION: NEVER connect the transceiver to a power
pack. Also, current may flow into nearby metal objects, such source that is DC fused at more than 5 A. Accidental reverse
as a necklace, etc. Therefore, be careful when carrying with, connection will be protected by this fuse, higher fuse values
or placing near metal objects, carrying in handbags, etc. will not give any protection against such accidents and the
transceiver will be ruined.
R DANGER! Use and charge only specified Icom bat-
tery packs with Icom radios or Icom chargers. Only Icom DO NOT allow children to play with any radio equipment
containing a transmitter.
battery packs are tested and approved for use with Icom ra-
dios or charged with Icom chargers. Using third-party or DO NOT operate the transceiver near unshielded electri-
counterfeit battery packs or chargers may cause smoke, fire, cal blasting caps or in an explosive atmosphere.
or cause the battery to burst.
DO NOT use or place the transceiver in direct sunlight or
in areas with temperatures below –10°C (+14°F) or above
R WARNING! NEVER hold the transceiver so that the
antenna is very close to, or touching exposed parts of the +60°C (+140°F).
body, especially the face or eyes, while transmitting. The Even when the transceiver power is OFF, a slight current still
transceiver will perform best if the microphone is 5 to 10 cm flows in the circuits. Remove the battery pack or case from
(231⁄32 to 315⁄16 inch) away from the lips and the transceiver is the transceiver when not using it for a long time. Otherwise,
vertical. the battery pack or installed dry cell batteries will become
exhausted.
R WARNING! NEVER operate the transceiver with a
headset or other audio accessories at high volume levels. FCC caution: Changes or modifications to this transceiver,
Hearing experts advise against continuous high volume op- not expressly approved by Icom Inc., could void your authority
eration. If you experience a ringing in your ears, reduce the to operate this transceiver under FCC regulations. (U.S.A.
volume level or discontinue use. only)
CAUTION: NEVER connect the transceiver to an AC Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorpo-
outlet or to a power source of more than 11.5 V DC. Such a rated (Japan) in Japan, the United States, the United Kingdom, Germany,
connection will damage the transceiver. France, Spain, Russia and/or other countries.
iii
TABLE OF CONTENTS
SAFETY TRAINING INFORMATION . .............................................. i ■ Programming a memory channel . ....................................... 13
FOREWORD ................................................................................... ii ■ Memory names .................................................................... 14
IMPORTANT . .................................................................................. ii ■ Clearing the memory contents ............................................. 14
EXPLICIT DEFINITIONS . ............................................................... ii 5 SCAN OPERATION ........................................................ 16 – 17
SUPPLIED ACCESSORIES . .......................................................... ii ■ Scan types ........................................................................... 16
PRECAUTIONS............................................................................... iii ■ COM band scan ................................................................... 16
TABLE OF CONTENTS . ................................................................ iv ■ Memory scan ....................................................................... 16
1 PANEL DESCRIPTION ....................................................... 1 – 6 ■ Weather channel scan (U.S.A. version only)............................. 17
■ Panel description ................................................................... 1 ■ “TAG” channels . .................................................................. 17
■ Function display ..................................................................... 5 6 VOR NAVIGATION (IC-A24 only).................................... 18 – 24
2 ACCESSORY ATTACHMENT ................................................... 7 ■ VOR indications ................................................................... 18
3 BASIC OPERATION . ........................................................ 8 – 11 ■ VOR functions ...................................................................... 19
■ Setting a frequency ................................................................ 8 ■ Flying to a VOR station ........................................................ 20
■ Setting a squelch level ........................................................... 8 ■ Entering a desired course .................................................... 22
■ Selecting a weather channel................................................... 8 ■ Crosschecking position ........................................................ 22
■ Receiving ............................................................................... 9 ■ Duplex operation (U.S.A. version only) .................................... 24
■ ANL function .......................................................................... 9 7 BATTERY PACKS ........................................................... 25 – 28
■ Transmitting ............................................................................ 9 ■ Battery charging . ................................................................. 25
■ Time-Out-Timer function (Australia version only) ................... 9 ■ Battery cautions ................................................................... 25
■ Low battery indicator . .......................................................... 10 ■ Optional battery case ........................................................... 26
■ Recall function ..................................................................... 10 ■ Optional battery chargers .................................................... 27
■ Setting weather alert function............................................... 11 8 CLONING ................................................................................ 29
■ Accessing the 121.5 MHz emergency frequency . ............... 11
■ Lock function ........................................................................ 11 9 TROUBLESHOOTING ............................................................ 30
■ Side tone function ................................................................ 11 10 SPECIFICATIONS ................................................................... 31
■ Setting beep tone . ............................................................... 11 11 OPTIONS ................................................................................ 32
4 MEMORY OPERATION . ................................................. 12 – 15 12 OPTIONAL HEADSET CONNECTION . ................................. 33
■ Memory channel selection ................................................... 12
■ Transferring memory contents . ............................................ 12
iv
1 PANEL DESCRIPTION
e r t
y
u
i
w
o !7
IC-A6
q WX-ALERT
!0
!1
!7
!2
!3
!6
Microphone
!5
Speaker
!4
!7
1
PANEL DESCRIPTION 1
!1 CLEAR KEY [CLR•DEL] (pp. 8–17) !6 ENTER KEY [ENT•WX] (pp. 8, 14)
➥ Push to return to the frequency mode, when ➥ Push to store the numeral input. Enters con-
memory channel, WX channel, 121.5 MHz, secutive zero digits. (p. 8)
squelch level setting or beep tone setting is se- ➥ P ush , then push [ENT• WX ] to enter the
lected. weather channel selection mode (U.S.A. ver-
➥ Push , then hold down [CLR•DEL] to delete sion only). (p. 8)
a recall frequency data. ➥ Push to program the memory name. (p. 14)
➥ Push to clear the entered comment of memory NOTE: S
ome functions may not be available depending on
name while programming. versions. Ask your authorized dealer for details.
➥ Push to stop the scan function to return to the
frequency mode while the scan function is op- • DC POWER CONNECTION
erating. R WARNING!
• N EVER modify the CP-20. A modification
!2 ANL KEY [ANL•SCAN] (pp. 9, 16, 17) could cause a fire or electrocution.
➥ Push to turn the ANL function ON or OFF. • NEVER cut or fray the CP-20’s power cable
➥ Push , then push [ANL•SCAN] to start the IC-A24/A6 when disconnecting/connecting the CP-20
scan function. from/to the cigarette lighter socket.
!4 DC POWER JACK
Connect the AC adapter or optional cable, to charge the
battery pack or to operate by external power. (see right il- To the cigarette
lustration) lighter socket
Wall charger
To [DC 11V]
!5 MEMORY MODE KEY [MR•MW] (pp. 12–15) To AC outlet
➥ Push to select the memory channel mode.
The shape may
➥ Push , then push [MR•MW] to program the differ depending
contents into the memory channels. on the version.
3
PANEL DESCRIPTION 1
4
1 PANEL DESCRIPTION
■ Function display
q FUNCTION INDICATOR (p. 2)
Appears when is pushed.
w TX INDICATOR (p. 9)
Appears while transmitting.
q w e r t y
e RX INDICATOR (p. 9)
Appears when receiving a signal, or when the squelch
opens.
1
i TAG CHANNEL INDICATOR (p. 17) !4 COURSE INDICATORS (IC-A24 only) (p. 19)
“ ” appears when the selected memory channel is set ➥ Indicates where your aircraft is located on a VOR radial
as a TAG channel. in the DVOR mode.
➥ Indicates where your desired course is located on a
o MEMORY CHANNEL INDICATOR (pp. 12–15) VOR radial in the CDI mode.
Shows the selected memory channel number.
!5 TO-FROM INDICATOR (IC-A24 only) (p. 19)
!0 MEMORY BANK NUMBER INDICATOR (p. 12) Indicates whether the VOR navigation information is
Shows the selected memory bank number. based on a course leading to the VOR station or leading
away from the VOR station.
!1 OVERFLOW INDICATOR (IC-A24 only) (pp. 18–22)
Appears when the deviation between the desired course
and flying course is over 10 degrees.
6
2 ACCESSORY ATTACHMENT
Slide the battery release button forward, then pull the battery
pack upward with the transceiver facing away from you.
8
3 BASIC OPERATION
■ Receiving ■ Transmitting
q Push [PWR] for 2 sec. to turn the power ON. CAUTION: Transmitting without an antenna may damage
w Push [SQL•WX-ALERT], then rotate [DIAL] counterclock- the transceiver.
wise to select the squelch level 0.
e Rotate [VOL] to adjust the audio level.
Push [SQL•WX-ALERT], then rotate [DIAL] clockwise until
r NOTE: To prevent interference, listen on the frequency
the noise is muted. before transmitting. If the frequency is busy, wait until the
• “ ” indicator disappears. channel is clear.
t Set the desired frequency using [DIAL] or keypad. q Set the desired frequency in COM band using [DIAL] or
y When a signal is received on the set frequency: keypad.
• “ ” indicator appears.
• COM band frequency range: 118.00–136.975 MHz
• Squelch opens and audio is emitted from the speaker.
w Hold down [PTT] to transmit.
• “ ” indicator appears.
When [SQL] setting is too “tight,” squelch may not open for
e Speak into the microphone at a normal voice level.
weak signals. To receive weaker signals, loosen the squelch. • DO NOT hold the transceiver too close to your mouth or speak
too loudly. This may distort the signal.
r Release [PTT] to return to receive.
■ ANL function
While receiving, the ANL (Automatic Noise Limiter) function ■ Time-Out-Timer function
reduces noise components such as those that are caused
by engine ignition systems while receiving.
(Australia version only)
• Push [ANL•SCAN] to turn the ANL function ON/OFF. To prevent prolonged transmission, and according to regula-
“ ” appears on the display while the ANL function is ON. tory requirements, the IC-A6 (Australia version only) has a
Time-Out-Timer function. This timer cuts a transmission OFF
after 3 minutes of continuous transmission.
9
BASIC OPERATION 3
■ Recall function
The recall function stores the last 10 frequencies used.
The function stores frequencies when the frequency is pro- D Replaces the stored recall channel
grammed and transmitted on (except memory, weather and q P ush or to select the recall channel to be re-
emergency channels). placed.
w Push , then push or to replace it.
D Recalling the stored frequencies • Replaces the selected channel into the previous channel when
➥ Push to recall the 1st stored frequency. is pushed and then is pushed.
• Replaces the selected channel into the next channel when
➥ Push to recall the 10th stored frequency.
is pushed and then is pushed.
• (e.g.) To replace “r0” which is stored as 121.375 MHz into “r1”,
push , then push .
: Push
: Push NOTE: When the number of stored frequencies reaches
10, channels are automatically deleted as needed, in the
order they were entered, beginning the oldest.
10
3 BASIC OPERATION
13
MEMORY OPERATION 4
■ Memory names
ï Programming memory names Key Character Key Character Key Character
The memory channel can display a 6-character name in- 1 1, Q, Z 2 2, A, B, C 3 3, D, E, F
stead of the programmed frequency. 4
4 4, G, H, I 5 5, J, K, L 6 6, M, N, O
q In the frequency mode, rotate [DIAL] to select the desired 7 7, P, R, S 8 8, T, U, V 9 9, W, X, Y
frequency in the frequency mode. ENT Program 0 0, space, -
w Push , then push [MR•MW] to program the contents
into the selected memory channel.
e Rotate [DIAL] to select the desired memory channel to be NOTE: When programming the memory name to the pro-
programmed. grammed memory channel do the following.
• Push , then push [0•BANK], and rotate [DIAL] to select the q Follow the same steps as in “Transferring memory con-
BANK number, if desired. Push [CLR•DEL] to exit the BANK se- tents” (see p. 12).
lection mode. w Follow steps w–y in “Programming memory names”
r Push [MR•MW] to enter the memory name programming (see left column).
mode.
• “-- -- -- -- -- -- ” appears on the display.
t Push the appropriate digit key several times to select the
desired character, as listed to the right. ■ Clearing the memory contents
• To erase a character, overwrite with a space (displayed as _).
• To move the cursor forwards or backwards, use [DIAL]. Unwanted memory channels can be cleared.
y Push [ENT•WX] to program the name.
• The memory name stops flashing. q Select the memory channel to be cleared.
• When no name is programmed, the display shows the operat- w Push , then hold down [CLR•DEL] for 1 sec.
ing frequency. • “-- -- -- -- -- --” appears momentarily, then the next selectable
• To clear the entered memory names, push [CLR•DEL] before channel appears.
pushing [ENT•WX].
14
4 MEMORY OPERATION
• EXAMPLE: Programming 125.000 MHz into memory BANK 1/ memory channel 17 with “AIR-23” as a comment.
Push
Push Push
(or rotate [DIAL])
Push Push
(or rotate [DIAL]) Push Push
Push
Push Push Push
15
SCAN OPERATION 5
■ Scan types ■ COM band scan
The U.S.A. version has 3 scan types to suit your needs. The q Push [CLR•DEL] to select the frequency mode.
non-U.S.A. versions have 2 scan types. w P ush [SQL• WX-ALERT ], then rotate [DIAL] to set the
squelch level to the point where noise is just muted. 4
COM BAND SCAN e Push , then push [ANL•SCAN] to start the scan.
108.00 118.00 136.975 Repeatedly scans • When a signal is received, the scan pauses until it disappears. 5
MHz MHz MHz a l l f r e q u e n c i e s • To change the scanning direction, rotate [DIAL].
o ve r t h e e n t i r e r To stop the scan, push [CLR•DEL].
Scan
COM band.
Jump
■ Memory scan
MEMORY SCAN q Push [MR•MW] to select the memory mode.
Repeatedly scans all • Push , then push [0•BANK], and rotate [DIAL] to select the
non-TAG channel selected memory bank’s BANK number, if desired. Push [CLR•DEL] to exit the BANK se-
Mch 2 Mch 4 Mch 6 “TAG” memor y chan- lection mode.
nels. Used for checking w P ush [SQL• WX-ALERT ], then rotate [DIAL] to set the
Mch 1 Mch 7
often-used channels squelch level to the point where noise is just muted.
non-TAG
Mch 19 Mch 10 Mch 8 channel and bypassing usually e Push , then push [ANL•SCAN] to start the scan.
busy channels such as • When a signal is received, the scan pauses until it disappears.
control-tower frequen- • To change the scanning direction, rotate [DIAL].
cies. r To stop the scan, push [CLR•DEL].
16
5 SCAN OPERATION
Push [F], then push [1 DVOR]. Push [F], then push [4 CDI].
CDI MODE
18
6 VOR NAVIGATION (IC-A24 ONLY)
NOTE:
D To select the DVOR mode • When using the ‘TO’ flag and passing through the VOR station,
When entering the NAV band, 108.000–117.975 MHz, the the ‘TO’ flag changes to the ‘FROM’ flag automatically.
IC-A24 selects the DVOR mode automatically. • When turning power ON, the ‘FROM’ flag is selected automati-
cally.
To show your aircraft’s direction to (or from) the VOR station,
push , then push [1•DVOR] to select the DVOR mode. D Selecting the next VOR station when using
Operating frequency can not be CDI mode (when using the course deviation needle)
changed. q Push , then push [1•DVOR] to select the DVOR mode.
Course deviation needle does not w Push the keypad or rotate [DIAL] to set the next VOR sta-
appear. tion’s frequency.
Course indicator shows your e Push , then push [4•CDI] to select the CDI mode.
direction to (or from) the VOR • Select ‘TO’ or ‘FROM’ flag, if desired.
station.
19
VOR NAVIGATION (IC-A24 ONLY) 6
■ Flying to a VOR station r The course deviation needle appears when your aircraft
is off course from the VOR station.
• ‘Ω’ or ‘≈’ appears to indicate your aircraft is off course to the
The IC-A24 shows the deviation from a VOR station. right or left, respectively. Correct your course until ‘Ω’ or ‘≈’ dis-
appears. Each arrow represents a two-degree deviation.
q Select a VOR station on your aeronautical chart and push t Push , then push [1•DVOR] to exit the CDI mode.
the keypad or rotate [DIAL] to set the frequency of the
station.
• The course indicator indicates where you are located on a ra- VOR INDICATOR NOTE
dial from the VOR station. ‘loc’ appears on the function display as shown below when 6
• The course indicator shows ‘- -’ when either aircraft is too far a localizer signal is received.
away from the VOR station or the frequency is not set correctly
at the VOR station. However, the function display does not indicate additional
w Select the ‘TO’ flag when flying to the VOR station, or se- information about the localizer signal.
lect the ‘FROM’ flag when flying away from the VOR sta-
tion.
• Push , then push [2•TO] to select ‘TO’.
• Push , then push [3•FROM] to select ‘FROM’.
e Push , then push [4•CDI] to select the CDI (Course
Deviation Indicator) mode.
• The course indicator shows ‘OF’ when the desired VOR signal
cannot be received.
0
330 340 N
310 320 350
THE AIRCRAFT IS ON COURSE
123.65
VORTAC 300 Magnetic
SEATTLE
290
280
10
20
north
116.8 Ch 115 SEA 270 30
260 40
250 50
240 60
230
VOR 70
rse
220 station 80
ed cou 210 90
D esir g 40 200 100
0
330 340 N
310 320 350
THE AIRCRAFT IS OFF COURSE
123.65
VORTAC 300 Magnetic
SEATTLE
290
280
10
20
north
116.8 Ch 115 SEA 270 30
260 40
4 6 250 50
ding
ft hea 240 60
Aircra ourse)
fc 230
VOR
(6 of ourse
70
w nc 220 station 80
Flo 210 90
be 200 100
uld
NOTE: The course deviation indica- sho 190 110
i r c raft 40 180
170 130
120
A
ding
160 150 140
tor appears when the aircraft is off
hea
course. In this example, the aircraft
is 6 degrees off course to the left.
The pilot must turn more than 6 de-
grees right to get back on course.
21
VOR NAVIGATION (IC-A24 ONLY) 6
q w e r
q Overflow indicator (left)
w Course deviation needles (left)
e Course deviation needles (right)
r Overflow indicator (right)
22
6 VOR NAVIGATION (IC-A24 ONLY)
CROSSCHECKING POSITION
123.65
VORTAC VORTAC
OLYMPIA 0 0 SEATTLE
330 340 330 340
113.4 Ch 81 OLM 310 320 350 310 320 350 116.8 Ch 115 SEA
300 300
290 10 290 10
280 20 280 20
270 30 270 30
N
260 40 260 40
Magnetic
250 250
50 50
north
240 60 240 60
230 230
VOR 70 VOR 70
220 station 80 220 station 80
210 90 210 90
200 100 200 100
190 110 190 110
180 120 180 120
170 130 170 130
160 150 140 160 150 140
23
VOR NAVIGATION (IC-A24 ONLY) 6
EXAMPLE: Programming 123.65 MHz as the transmit frequency in the duplex function.
24
7 BATTERY PACKS
To the cigarette
lighter socket
To [DC 11V] Wall charger
To AC outlet
The shape may
differ depending
on the version.
26
7 BATTERY PACKS
w
CAUTION:
Supplied • DO NOT push or force the latch with a screw driver, etc.,
screws to remove it.
• DO NOT bend the latch when the adapter and spacer
are not joined together. This will cause weakening of the
latch plastic.
• Both cases may break the latch and it may not be able
to be reattached.
• BE CAREFUL not to lose the spacer (Spacer B/C) after
removing it from the adapter (Spacer A).
27
BATTERY PACKS 7
D Rapid charging with the BC-119N+AD-101 D Rapid charging with the BC-121N+AD-101
The optional BC-119N provides rapid charging of the battery The optional BC-121N allows up to 6 battery packs to be
packs. The following are additionally required. charged simultaneously. The following are additionally re-
• AD-101 charger adapter. quired.
• An AC adapter (may be supplied with BC-119N depending on ver- • Six AD-101 charger adapters.
sions) or the DC power cable (CP-20). • An AC adapter (BC-157) or the DC power cable (OPC-656).
The adapter (Spacer A) only is required for IC-A24/A6. When re- The adapter (Spacer A) only is required for IC-A24/A6. When re-
moving the spacer (Spacer B/C), push the latch carefully with your moving the spacer (Spacer B/C), push the latch carefully with your
finger to remove the spacer (Spacer B/C) from the adapter finger to remove the spacer (Spacer B/C) from the adapter
(Spacer A). See p. 27 for details. (Spacer A). See p. 27 for details. 7
Turn power OFF IC-A24/A6 IC-A24/A6 8
Turn power OFF
BP-209N/BP-210N BP-209N/BP-210N
AD-99N (supplied
with AD-101)
AD-101 charger adapters are
AD-99N (supplied installed in each slot.
with AD-101) The AD-101 charger adapter
is installed in the slot.
AC adapter
(BC-157:
Purchase
separately) DC power cable (OPC-656)
AC adapter (Connect with the DC power supply;
13.8 V/at least 7 A)
28
8 CLONING
Cloning allows you to quickly and easily transfer the r When cloning is finished, turn power OFF, then ON again
programmed data from one transceiver to another to exit the cloning mode.
transceiver, or, data from a PC to a transceiver, using the
optional CS-A24 cloning software. NOTE: DO NOT transfer the data from a IC-A24 to a IC-
A6, when the data contains the NAV band data. In such
D Transceiver to transceiver cloning case, a cloning error may occur.
q C onnect the OPC-474 CLONING CABLE with adapter
plugs to the [SP/MIC] jack of the master and sub trans- DCloning using PC
ceivers.
Data can be cloned to and from a PC (Microsoft®, Windows®
• The master transceiver is used to send data to the sub trans-
ceiver. 98/98SE/Me/2000/XP) using the optional CS-A24 CLON-
w While holding down [MR•MW], push ING SOFTWARE and the optional OPC-478 (RS-232C type)
[PWR] to enter the cloning mode (to or OPC-478U (USB type) CLONING CABLE. Consult the CS-
operate the master transceiver A24 CLONING SOFTWARE HELP file for details.
only).
• “CLONE” appears and the transceivers D Cloning error
enter the clone standby condition. NOTE: DO NOT push [ENT•WX] on the sub transceiver
e Push [MR•MW] on the master trans- during cloning. This will cause a cloning error.
ceiver.
• “CL-OUT” appears in the master trans-
When the display at right appears, a
ceiver’s display.
• “ COURSE DEVIATION NEEDLES”
cloning error has occurred.
shows that cloning is taking place “COURSE DEVIATION
NEEDLES” shows that
cloning is taking place.
In this case, both transceivers automatically return to the
• “ CL-IN” appears automatically in the clone standby condition and cloning must be repeated.
sub transceiver’s display.
29
TROUBLESHOOTING 9
If your transceiver seems to be malfunctioning, please check the following points before sending it to a service center.
PROBLEM POSSIBLE CAUSE SOLUTION REF.
No power comes on. • The battery is exhausted. • Recharge the battery pack. pp. 25–28
• Bad connection for the battery pack. • Check the connection to the transceiver. p. 7
• The CP-20’s fuse is blown. • C heck for the cause, then replace the p. 30
CP-20’s fuse to new one.
No sound comes from • Squelch level is too deep. • Set squelch to the threshold point. p. 8
the speaker. • Volume level is too low. • Set [VOL] to a suitable level. p. 9
Transmitting impossible. • WX channels or NAV band is selected. • Set COM band in frequency mode. p. 8
• The battery is exhausted. • Recharge the battery pack. pp. 25–28
Operating frequency or • Lock function is activated. • Push , then push [7• ]. p. 11 8
memory channel can not
be changed. 9
Scan does not start. • All memory channels in the selected bank • S et the “TAG” settings of desired p. 17
are not programmed as “TAG” channels. channels. 10
• Squelch is open. • Set the squelch level to tighten. p. 8
• T here is not more than 2 memorized • Program 2 or more memory channels. p. 16
channels.
No beep sounds. • Beep tones turned OFF. • P ush , then push [8• BEEP ], and p. 11
rotate [DIAL] to adjust the beep tone
level.
When using an optional • The side tone function is activated. • Push [PTT], then rotate [DIAL] to set the p. 11
HM-173, your voice monitoring level to ‘ST-0’ (The side tone
hears from the speaker function is OFF).
during transmitting.
D CP-20 fuse replacement
If the fuse blows or the receiver stops functioning while
operating with the optional CP-20 cigarette lighter cable, Fuse 8 A
find the source of the problem if possible, and replace the
damaged fuse with a new rated one (FGB 8 A) as shown
right.
30
10 SPECIFICATIONS
PTT switch
PTT Use a PTT switch with a
3.5 mm (1/8") diameter
plug, if required.
OPC-499
HEADSET
(Must be purchased
separately)
NOTICE!
Some headsets do not work properly when used with the
IC-A24/A6.
IC-A24/A6
Therefore, ask your dealer for details about headsets
compatible for operation with the IC-A24/A6 with the
headset.
33
MEMO
12
13
34
A-6403D-1EX-i
Printed in Japan
© 2004–2010 Icom Inc.
Printed on recycled paper with soy ink. 1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan