EntryProx™

Quick Reference
Installation Guide

TD1131 rev0800
EntyProx™ Installation Introduction

Table of Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . .ii
Installing EntryProx . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Wiring EntryProx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1
Programming Hints . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Installation Introduction EntyProx™
Installation Introduction EntyProx™

INTRODUCTION
This User’s Guide is intended for experienced installers of the
EntryProx unit. It is not intended for routine use and does not replace
the more comprehensive information contained in the EntryProx
Installation/Programming Manual. The Guide provides basic informa-
tion and instructions for installing, wiring, and programming the
EntryProx unit.
• For product specifications and functional descriptions, refer to
the Product Overview section.
• For instructions on installation methods and wiring diagrams,
refer to the Installing and Wiring sections.
• For information on available programming options, refer to the
Programming section.
If you experience problems when installing or wiring the EntryProx
unit, please contact your local EntryProx distributor.

i
EntyProx™ Installation Introduction

PRODUCT OVERVIEW
The EntryProx Access Control unit provides card and keypad access
control for a single entrance. The unit can be installed in a typical
one-stage configuration or a higher security two-stage (remote)
configuration. The EntryProx unit is compatible with all HID proximity
cards up to 37 bits. Manual or batch programming can only be com-
pleted with a 26-bit card. All programming options are performed
using the controller keypad.

Unit Capacity
The EntryProx unit can accommodate up to 2,000 users. Each user
can have a card/tag, a PIN code, or a card/tag PLUS a PIN code.

Transactions
A maximum of 1,000 transactions can be stored in the EntryProx
unit. Each transaction includes the time, the date, the user “slot
number,” and the event.

ii
Installation Introduction EntyProx™

Figure 1: EntryProx Assembly Parts

TABLE 1: FACTORY SUPPLIED PARTS LIST


DESCRIPTION
A. Controller Keypad Unit G. Press to Exit label

B. Controller Keypad Backplate H. Silicone Rubber "Dogbone"

C. Cable Assemblies I. Self-Adhering Pads

D. Antenna Backplate J. 2-pin Jumper

E. Antenna Housing K. Filler Piece

F. Mounting Screws

TABLE 2: INSTALLER SUPPLIED PARTS LIST


DESCRIPTION
Appropriate DC power supply Power supply cable (18AWG-22AWG)

Appropriate electrical tools Door lock cable (18AWG-22AWG)

Recommended remote antenna cable


Door monitor cable (18AWG-22AWG)
ALPHA 1174C (22AWG)

Wiegand interface cable ALPHA


Request to Exit cable (if using remote
1295C (22AWG) (only if using a
switch)
separate Wiegand control panel)

iii
EntyProx™ Installation Introduction

TABLE 3: SPECIFICATIONS
CATEGORY REQUIREMENTS

ENVIRONMENTAL
Operating Temperature -20° F to 130° F
(-28° C to 54° C)
Operating Humidity 5% to 95% relative humidity, non-
condensing
ELECTRICAL
Power Supply/Current Requirements
(Does not include locking device or 10 – 15 VDC, linear filtered and
peripherals, include both devices in regulated power supply recommended
your current requirements 150 mA
calculations.)
MECHANICAL
Height 5.25 in (13.3 cm)
Width 2.75 in (7 cm)
Depth 1.375 in (3.5 cm)
RELAY OUTPUTS
Main Relay Form C (switches up to 4A)
Aux Relay Form C (switches up to 1A)
SOUNDER 4000 Hz, defeatable
LEDs Bi-Color (red/green) Amber

TABLE 4: DEFAULT SETTINGS


PARAMETER DEFAULT SETTING
Master Code (user one) 1234*

Main Relay energizes for 5 seconds

Audible Keypress Feedback ON

Local Propped Door Sounder activates after 30 seconds

Local Forced Door Sounder activates after 10 seconds

Printer Output Port Infrared (IR) port

iv
Installation Section 1 EntyProx™

Section 1 - Installing the EntryProx


You can install the EntryProx unit by using a standard installation
method or a secure installation method. In a standard installation
the antenna housing remains intact with the controller keypad. A
standard installation involves:
• Mounting the EntryProx unit outside a secured area, such as
outside a main entrance.
• Wiring the EntryProx unit for door locks and alarm out-puts. In
a secure installation the antenna housing is removed from the
controller keypad and mounted outside a secured area. The
blank filler piece is then inserted into the controller keypad in
its place.
Note: If you enable the Request to Exit function, apply the "Press
to Exit" label to the filler piece. Refer to the "Wiring the Request to
Exit Switch" section for more information.
A secure installation involves:
• Mounting the EntryProx unit in a secured area, such as inside
a main reception area.
• Wiring the EntryProx unit for door locks and alarm out-puts.
• Mounting the Antenna Housing.
• Attaching the Press to Exit label (optional).
Note: If you use the secure installation method, you need to
mount and wire the antenna housing no more than 10-feet away
from the controller keypad unit.

1-1
Installation Section 1 EntyProx™

Mounting the EntryProx Unit


To mount the EntryProx unit to a wall surface, refer to Figure 2
and follow these instructions.
Instructions:
1. Remove the hex screw located at the bottom of the
EntryProx unit.
2. Disconnect the backplate of the EntryProx unit from the front
controller keypad.
3. Remove the wire exits and mounting hole cut-outs from the
backplate as shown in Figure 2.
Note: If you mount the EntryProx unit to a glass surface DO NOT
remove the wire exits on the backplate. Remove the appropriate
wire exit cut-outs located on each side of the controller keypad
case.
4. Attach the backplate to a wall or glass surface using the
mounting screws or the self-adhesive fasteners.

FIGURE 2: REMOVING THE WIRING EXITS AND MOUNTING HOLES

Mounting
Holes

1-2
EntyProx™ Installation Section 1

Wiring the Controller Keypad for a Standard Installation


To wire the EntryProx unit for a standard installation, refer to
Figures 3 and 4 and follow these instructions.
Instructions:
1. Touch a grounded object BEFORE touching the main circuit
board to guard against possible static discharges.
2. Remove the main circuit board by pushing outward on the
two spring tabs in the direction shown in Figure 3.
3. Lift the main circuit board.
FIGURE 3: REMOVING THE CIRCUIT BOARD

Note: A ribbon cable holds the main circuit board to the controller
keypad board. DO NOT CUT OR REMOVE this cable from its
connector.
4. Make the wiring connections for the door locks and alarm
outputs. Refer to the “Wiring EntryProx” section for appro-
priate wiring diagrams.

1-3
Installation Section 1 EntyProx™

5. Pull the wires through the backplate as shown in Figure 4.


6. Reattach the main circuit board to the controller keypad unit.
7. Attach the controller keypad unit to the mounted backplate
and secure the EntryProx unit with a hex screw or tamper
screw.

FIGURE 4: PULLING THE WIRES THROUGH THE BACKPLATE

1-4
EntyProx™ Installation Section 1

FIGURE 5: REMOVING THE P4 CONNECTOR

P4 Connector
Cable Assembly

Wiring the Controller Keypad for a Secure Installation


In a secure installation, the antenna housing is removed from the
controller keypad and is located no more than 10 feet away from
the EntryProx unit. To wire the EntryProx unit for a secure installa-
tion, refer to Figures 5 and 6 and follow these instructions.
Instructions:
1. Touch a grounded object BEFORE touching the main circuit
board to guard against possible static discharges.
2. Remove the main circuit board by pushing outward on the
two spring tabs in the direction shown in Figure 3.
3. Lift the main circuit board.
Note: A ribbon cable holds the main circuit board to the controller
keypad board. DO NOT CUT OR REMOVE this cable from its
connector.
4. Unplug the four-pin connector P4 from the main circuit
board. See Figure 5.
5. Release the antenna housing from the controller keypad by
pressing inward on the four securing tabs.
6. Remove the antenna housing from the controller keypad by
pushing forward as shown in Figure 6.
1-5
Installation Section 1 EntyProx™

FIGURE 6: REMOVING THE ANTENNA HOUSING

7. Insert the extra 10-inch antenna cable assembly into con-


nector P4.
8. Splice in additional antenna cable Alpha 1174C (22AWG) up
to a maximum of 10 feet.
Note: The Alpha 1174C antenna cable is not supplied with the
EntryProx unit.
9. Pull the additional antenna cable through the mounted back-
plate as shown in Figure 4.
10. Make the wiring connections for the Request to Exit switch,
the door locks, and the alarm outputs. Refer to the “Wiring
EntryProx” section for appropriate wiring diagrams.
11. Reattach the main circuit board to the controller keypad
unit.
12. Attach the controller keypad unit to the mounted backplate
and secure the EntryProx unit with a hex screw or tamper
screw.
13. Run the additional antenna cable to the antenna housing
location.
14. Mount and wire the antenna housing.

1-6
EntyProx™ Installation Section 1

FIGURE 7: MOUNTING THE ANTENNA BACKPLATE

Moisture
Release
Holes
Mounting and Wiring the Antenna Housing for a Secure
Installation
To mount and wire the antenna housing, refer to Figures 7 and 8
and follow these instructions.
Instructions:
1. Position and secure the antenna backplate to the mounting
surface so that the two moisture release holes are on the
bottom.
2. Pull the antenna cable assembly through the backplate’s
cable holes.
3. Attach the antenna housing to the backplate by inserting the
four securing tabs into the backplate.
4. Cut the plastic connector off the antenna cable assembly.
5. Splice in the additional antenna cable. Be careful to match
the wire colors to the proper pin connectors on the 10-inch
antenna cable assembly.
6. Seal the wire holes with silicone.
FIGURE 8: ATTACHING THE ANTENNA HOUSING

1-7
Installation Section 1 EntyProx™

FIGURE 9: USING THE FILLER PIECE AS A REQUEST TO EXIT SWITCH

Selecting a Filler or Request to Exit Operation


The filler piece replaces the antenna housing on the controller key-
pad when you use the secure installation. If you are not going to
use the filler piece as a Request to Exit switch:
• Insert the filler piece into the opening on the controller key
pad.
• Apply the blank label.
If you are going to use the filler piece as a Request to Exit switch:
• Remove the two plastic side tabs on the filler piece.
• Apply the “Press to Exit” label to the filler piece.
• Insert the silicone rubber “dogbone” over the two aligned pins
on the switch activator.
• Insert the filler piece into the opening on the controller key
pad.
• Set the internal request to exit switch to ON. Refer to Table 6:
Program Commands, Programming Code 30, Option 7
Wiegand
Note: Refer to the “Wiring the Request to Exit Switch” section for
the appropriate wiring diagrams.

1-8
Wiring the EntryProx - Section 2 EntyProx™

Section 2 - Wiring the EntryProx


This section includes three wiring diagrams:
• Wiring the main relay
• Wiring the auxiliary relay
• Wiring the Request to Exit switch
Figure 10 illustrates the location of the four pin connectors on the
main circuit board. Table 5 on Page 2-2 describes each pin and
its use.
FIGURE 10: PIN LOCATOR DIAGRAM
1234

1
2
1 3
2 4
3 5
4 6
5

1
2
3
4

2-1
Wiring the EntryProx - Section 2 EntyProx™

TABLE 5: PIN CONNECTOR DESCRIPTIONS/USES

PIN WIRE
PIN USE
CONNECTOR COLOR

1 Gray Main Relay, Normally Closed

2 Green Main Relay, Normally Closed

P1 (5-pin) 3 Blue Main Relay, Common

4 Black Ground

5 Red Power In, +12 VDC

1 Green Aux Relay, Normally Closed

2 Gray Aux Relay, Normally Closed

3 Blue Aux Relay, Common


P2 (6-pin)
4 Brown REX Loop (if used) (NO contact)

5 Orange Door Loop Contact (NC contact)

6 White Loop Common (shared by REX and door loop)

1 Blue Not used

2 Brown Wiegand LED Control, user-assigned


P3 (4-pin)
3 White Wiegand Data 1

4 Green Wiegand Data 0

1 Red Bi-Color LED (Red +)

2 Black Bi-Color LED (Green +)


P4 (4-pin)
3 White Antenna +

4 White Antenna -

2-2
EntyProx™ Wiring the EntryProx - Section 2

WIRING THE MAIN RELAY


The main relay for the door locking device is wired to connector
P1 on the EntryProx main circuit board. To wire the EntryProx unit
to the door locking device, refer to Figures 11 and 12 and follow
these instructions.
Instructions:
1. Power off the EntryProx unit and remove the controller key
pad from the backplate (if not already removed).
2. Remove the main circuit board from the controller keypad
as shown in Figure 3.
3. Locate connector P1 on the main circuit board.
4. Refer to Figure 11 to make the wiring connections for a Fail-
Secure Strike or Lock.
5. Refer to Figure 12 to make the wiring connections for a
Maglock or Fail-Safe Strike.

FIGURE 11: ELECTRIC STRIKE (FAIL SECURE WIRING DIAGRAM)

2-3
Wiring the EntryProx - Section 2 EntyProx™

6. Reattach the main circuit board to the controller keypad.


7. Reattach the controller keypad to the backplate and secure
the EntryProx unit with a hex screw or tamper screw.
Note: You can make the wiring connections for a gate actuator
(diagram not shown) by connecting the Blue (C) wire and the
Green (N/O) wire directly to the input. DO NOT connect a power
supply to the relay.

2-4
EntyProx™ Wiring the EntryProx - Section 2

FIGURE 12: MAGLOCK (FAIL SAFE WIRING DIAGRAM)

WIRING THE AUXILIARY RELAY


The EntryProx unit has an auxiliary relay feature that allows for
customized alarm programming. Pins 1, 2, and 3 on the P2
connector can be wired for one of the following alarm outputs:
• Alarm shunt
• Forced or propped door
The alarm shunt operation allows you to use the auxiliary relay to
bypass a door contact that is monitored by a separate alarm
system. If the entry or exit is controlled by the EntryProx unit, an
intrusion alarm will not be generated if the door is opened using an
access card or PIN number. The forced or propped door operation
allows you to use the auxiliary relay to install a local warning, such
as an audible or visual indicator if:
• A door is opened without using an access card or PIN
number at the EntryProx unit.
• A door is legitimately opened but is held open too long.
Note: The auxiliary relay audible and visual indicators and the
door open times can be programmed. Refer to Table 6: Program
Commands for more information.
2-5
Wiring the EntryProx - Section 2 EntyProx™

To wire the auxiliary relay, refer to Figures 13 and 14 and follow


these instructions.
Instructions:
1. Power off the EntryProx unit and remove the controller key
pad from the backplate (if not already removed).
2. Remove the main circuit board from the controller keypad as
shown in Figure 3.
3. Locate connector P2 on the main circuit board.
4. Refer to Figure 13 to make the wiring connections for the
alarm shunt operation.
5. Refer to Figure 14 to make the wiring connections for the
forced or propped door operation.
6. Reattach the main circuit board to the controller keypad.
7. Reattach the controller keypad to the backplate and secure
the EntryProx unit with a hex screw or tamper screw.

FIGURE 13: WIRING AUX RELAY FOR ALARM SHUNT OPERATION

Door Contact
(Monitored by
Alarm Panel)

Green
(N/O)

Door Contact
(Monitored by
EntryProx Unit)

2-6
EntyProx™ Wiring the EntryProx - Section 2

FIGURE 14: WIRING AUX RELAY FOR PROPPED/FORCED DOOR ALARM

BLUE (C)

ORANGE

Door Contact
(Monitored by
EntryProx unit)

2-7
Wiring the EntryProx - Section 2 EntyProx™

WIRING THE REQUEST TO EXIT SWITCH


The EntryProx Request to Exit switch is a momentary input that
engages the main relay and is intended for use with secure instal-
lations. If the alarm shunt relay is enabled, the Request to Exit
switch is activated to prevent false alarms. The Transaction Log
records all Request to Exit usages for monitoring purposes. To
wire the EntryProx unit for the Request to Exit switch, refer to
Figures 15 and 16 and follow these instructions.
Instructions:
1. Power off the EntryProx unit and remove the controller
keypad from the backplate (if not already removed).
2. Remove the main circuit board from the controller keypad
as shown in Figure 3.
3. Locate connector P2 on the main circuit board.
4. Refer to Figure 15 to make the wiring connections for using
a door contact.
5. Refer to Figure 16 to make the wiring connections for NOT
using a door contact.
Note: If you do not use a door contact, you need to twist the white
and orange wires together or the REX input will not function.
6. Reattach the main circuit board to the controller keypad.
7. Reattach the controller keypad to the backplate and secure
the EntryProx unit with a hex screw or tamper screw.
Note: The door contact must be closed for the Request to Exit
feature to work properly.

2-8
EntyProx™ Wiring the EntryProx - Section 2

FIGURE 15: WIRING REQUEST TO EXIT SWITCH (WITH DOOR CONTACT)

FIGURE 16: WIRING REQUEST TO EXIT SWITCH (NO DOOR CONTACT)

2-9
Wiring the EntryProx - Section 2 EntyProx™

2-10
Programming the EntryProx - Section 3 EntyProx™

Section 3 - Programming the EntryProx


Table 6 describes the programming commands available with the
EntryProx unit and explains how to execute them. For more infor-
mation on programming options, you can download the
Installation/Programming Manual from HID’s web site
(www.HIDCorp.com), or contact your local distributor. If you want
to program the EntryProx unit to operate with a separate Wiegand
central access panel, the following features are not accessible:
• The EntryProx unit does not control door lock or unlocking
operations.
• The EntryProx unit is not able to store codes in memory.
• The main and auxiliary relay functions are turned off.
For more information on programming the EntryProx unit for
Wiegand operations, please contact your local distributor.
Note: Defaults are in bold. References in parenthesis are in the
Installation/Programming.

3-1
Programming the EntryProx - Section 3 EntyProx™

TABLE 6: PROGRAM COMMANDS

If You Want To… Press Details

Enter program mode 99 # (Master Code) * Yellow LED blinks slowly

Change master code 1 # (new code) * (repeat Example' 1234 master code
Code-only operations code) * (1 #1234 * 1234 *)
Set main relay time 11 # tt # 0 # ** tt = 1 – 99 seconds

0 = disabled
1 = shunt
Set AUX relay output 15 # output # 0 # **
2 = forced door
3 = propped door
Example: To delete user 100,
Delete users User number # **
press: 100#**
Print a transaction log 70 # 0 # 0 # **

See below for Option


Set/clear standard option 30 # option # s/c # ** numbers and descriptions

Option Number/Description Set/Clear

0: Audio keypress feature 0 = OFF/1 = ON


1: Visual keypress feature 0 = OFF/1 = ON
2: Auto entry enable 0 = OFF/1 = ON

3: Stand-alone/Wiegand operation 0 = standalone/1 = Wiegand

4: Facility code access 0 = OFF/1 = ON

5: Forced door audio alert 0 = OFF/1 = ON


6: Propped door audio alert 0 = OFF/1 = ON
7: Internal Request to Exit switch 0 = OFF/1 = ON

8: US/EU date format 0 = US/1 = European

9: Wiegand red LED enable 0 = OFF/1 = ON


10: Wiegand red LED active state 0 = LOW/1 = HIGH

11: Wiegand green LED enable 0 = OFF/1 = ON


12: Wiegand green LED active 0 = LOW/1 = HIGH

13: Daylight saving time 0 = OFF/1 = ON

Print programmed user This feature is only available


25 # 0 # 0 # **
list with an optional IR printer

Print programmed user


32 # parameter # value # This feature is only available
list (starting at a certain
** with an optional IR printer
user)

Parameter
Change Wiegand 32 # parameter # value # 0, Wiegand pulse count
parameters ** 1, Wiegand interpulse
2, facility code

hhmm = hour/minute, 24-hr


Set system time 41 # hhmm # 0 # **
format

mmddyy = month, day, year;


Set system date 42 # mmddyy # dow # ** dow = day of week,
1 = Sunday

Set door number 43 # nnnn # 0 # ** nnnn = door number

3-2
EntyProx™ Programming the EntryProx - Section 3

FIGURE 6: PROGRAMMING COMMANDS (continued)

Set propped door time ttt = propped door time, to


(this sets time for both nearest 10's seconds,
44 # ttt # 0 # **
the Aux Relay and local entered as 10 – 990;
sounder) default = 30 seconds

ttt = forced door time, to


Set forced door time (this
nearest 10's seconds,
sets time for both the Aux 45 # ttt # 0 # **
entered as 10 –990; default =
Relay and local sounder)
10 seconds

Delete memory except


user list and restore
40 # 00000 # 00000 # **
system defaults (also see
command 46)

Delete all memory and


46 # 00000 # 00000 # **
reset system defaults

Program user: Code 0 – Toggle/latch strike,


50 # user-type # user
ONLY 1 – Normal Access,
location # code * repeat
2 – Log Dump, and
code *
Note: You can program the four

types of users shown to the right


3 – Lockout

50 # user-type # user
Program user:
location # * repeat code *
Code AND Card
<present card>

50 # user-type # user
Program user:
location # * * <present
Card ONLY
card>

The card ID appears on the


Program card user 51 # user-type # user
card (facility code must be
manually: Card ONLY location # card ID * card
entered first; see 32 # 2 #
(26-bit cards ONLY) ID *
command)

52 # user-type # user
Program user:
location # code * repeat
Code OR Card
code * <present card>

The card ID appears on the


Perform batch entry of
56 # total count # start card; (facility code must be
users: Card ONLY (26-
card # card ID * card ID * entered first; see 32 # 2 #
bit cards ONLY)
command)

Print Transaction Log via


70# 0# 0# **
IR port

Set transaction log mask


(set/clear event logging): 73 # event # set/clear # ** See below
set = 1, clear = 2

3-3
Programming the EntryProx - Section 3 EntyProx™

FIGURE 6: PROGRAMMING COMMANDS (continued)


Code – Transaction Event

01 – Access Denied
02 – Program Denied
03 – Program Mode
04 – Request to Exit
05 – Door Ajar
06 – Door Closed
07 – Forced Door
08 – Log Erased
09 – Facility Access
16 – Print
17 – Access
20 – Toggle ON
21 – Toggle OFF
24 – Lockout ON
25 – Lockout OFF
27 – Mismatch

Reset transaction log 76 # 00000 # 00000 # **

To exit Program mode * (after final command) Yellow LED stops flashing

3-4
EntyProx™ Programming the EntryProx - Section 3

TABLE 7: LED INDICATORS AND AUDIO OPERATIONS

LED or Visual/Audible
Description
Sounder Condition

Yellow LED Slow blink Unites is in Program mode

Verify mode is active (checking


Rapid blink that the last two values in
sequence match)

Steady Program error; to clear, press *

Memory (EEPROM) erase is in


Very rapid blink progress (commands 40/46,
loop-back)

LED or Visual/Audible
Description
Sounder Condition

Bi-Color LED Steady red Strike is locked

Strike is energized (timed or


Steady green
latched)
Strike toggle is unlocked and
Solid green with red flicker
user lockout active

Awaiting second form of ID


Red/green alternating during "Card AND Code" access
attempt

User lockout is active and strike


locked; red LED drops out for
Red blink 100 ms every second; normal
users cannot change the state of
the relay

LED or Visual/Audible
Description
Sounder Condition

Sounder Short beep


Propped door is active
(100 ms) every 2 seconds

Sounder ½ second on, ½


Forced door is active
second off

3 rapid beeps after code is


Code or Card is not found
entered or card is presented

3 slow beeps (250 ms), then


Self-test is complete
a single beep

1 single beep Valid card access

3-5
Programming the EntryProx - Section 3 EntyProx™

PROGRAMMING HINTS

Wiegand Programming:
• If you are using 26-bit cards with one common facility code,
enter that code under Programming Code 32, parameter 2,
facility code, to allow batch programming or facility code only
operation.
• Review Programming Code 30, Options 0-13 to check if any
changes are needed.

User Card/PIN Code Programming:


• DO NOT program an access card or PIN code into User #1.
This is reserved for the Master Password only.
• Keep a written record of access cards and PIN codes. See
the example “Users Chart” located at the back of the manual.
• When using a PIN code to open a controlled door or gate,
always follow with the asterick (*) key.

• When using a PIN code and an access card, the code may be
entered before or after presenting the access card to the
reader. The LED flashes alternate red/green until both IDs are
presented.

3-6
5007 South Howell Avenue • Milwaukee, WI 53207 • (800)323-4576
www.nciaccess.com

S-ar putea să vă placă și