Sunteți pe pagina 1din 2

Central standard

HCS01.1 ZN 41002-011
IndraDrive drive controller - Type code 2008-09-11

Drive controller Replacment for


ZN 41002-011 : 2008-04-30

1 Aim
Uniform coding of the drive controller HCS01.1 in all systems (e.g., SAP, nameplates).

2 Scope
This standard applies to Bosch Rexroth AG and its subsidiaries and country units.

3 Responsibilities
BRC/SAL is responsible for the preparation, care and content of this standard.

4 Type code
Abbrev. 1 2 3 4
column 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
Example: H C S 0 1 . 1 E - W 0 0 1 3 - A - 0 2 - E - S 3 - E C - N N - N N - N N - F W

Product
HCS . . . . . . . = HCS
© Bosch Rexroth AG 2008

Line
Up to 3 kW . . . . . . . . . = 01

Design
1......................=1

Power supply
Feeding . . . . . . . . . . . . . . . . . . = E

Cooling mode
Air, internal . . . . . . . . . . . . . . . . . . = W

Maximum current
At mains connecting voltage "02"
3 A . . . . . . . . . . . . . . . . . . . . . . . . . . = 0003 1
ZN-41002-011_NOR_N_EN_2008-09-11.fh11

6 A . . . . . . . . . . . . . . . . . . . . . . . . . . = 0006
9 A . . . . . . . . . . . . . . . . . . . . . . . . . . = 0009 1
13 A . . . . . . . . . . . . . . . . . . . . . . . . . . = 0013
At mains connecting voltage "03"
5 A . . . . . . . . . . . . . . . . . . . . . . . . . . = 0005 1
8 A . . . . . . . . . . . . . . . . . . . . . . . . . . = 0008
18 A . . . . . . . . . . . . . . . . . . . . . . . . . . = 0018 1
28 A . . . . . . . . . . . . . . . . . . . . . . . . . . = 0028

Protection mode
IP 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . = A

Bosch Rexroth AG created: BRC/SAL, Th. Gensler


Maria-Theresien-Straße 23 • 97816 Lohr a. Main
Germany approved: BRC/SAL, M. Wetzel
Original standard Page 1 / 2
Page 2 / 2
HCS01.1, IndraDrive drive controller - Type code ZN 41002-011 : 2008-09-11

Abbrev. 1 2 3 4
column 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
Example: H C S 0 1 . 1 E - W 0 0 1 3 - A - 0 2 - E - S 3 - E C - N N - N N - N N - F W

Mains connecting voltage


3 x AC 110 to 230 V ±10% . . . . . . . . . . . . . . . . . . . . . = 02
3 x AC 200 to 500 V ±10% . . . . . . . . . . . . . . . . . . . . . = 03

Control unit model


Basic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . = B
Economy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . = E

Communication
MultiEthernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . = ET 1
SERCOS III . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . = S3 2

Interface 1
Encoder IndraDyn / Hiperface® / 1Vss / TTL / EnDat 2.1/2.2 . . . . . . . . . . . = EC

Interface 2
Encoder IndraDyn / Hiperface® / 1Vss / TTL / EnDat 2.1/2.2. . . . . . . . . . . . . . = EC 1
Not equipped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . = NN
PROFIBUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . = PB 1

Interface 3
Starting lockout SIL/PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . = L2
Not equipped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . = NN
Safety technology I/O SIL/PL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . = S2 1

Other design
None . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . = NN

Firmware
Denotes that firmware must be ordered as separate subposition . . . . . . . . . . . . . . . . . . . . . . . . . . = FW

Note
1 Not available with design of control unit "E"
2 Only available with design of control unit "E"

5 Standard reference
Standard Edition Title
DIN EN 60529 2000-09 Degree of Protection (IP-Code)